Loading...
406 VENETIAN DRU.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1 -9. OMB No. 1660 -0008 Expiration Date: November 30, 2018 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name PHILLIP S. TOWNS & MICHELLE N. TOWNS Policy Number: A2. Budding Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 406 VENETIAN DRIVE Company NAIC Number: City State ZIP Code CLEARWATER Florida 33755 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) WEST 35' OF LOT 5 & EAST 15' OF LOT 6, BLOCK 1, NORTH SHORE PARK (PARCEL "B ") A4. Building Use (e.g., A5. Latitude /Longitude: A6. Attach at least A7. Building Diagram A8. For a building a) Square footage b) Number of permanent c) Total net area d) Engineered A9. For a building with a) Square footage b) Number of permanent c) Total net area d) Engineered Residential, Non - Residential, Addition, Accessory, etc.) Lat. 27.98709 Long. - 82.79682 RESIDENTIAL Horizontal Datum: insurance. above NAD 1927 adjacent grade grade 0 x NAD 1983 12 2 photographs Number with a crawlspace of crawlspace flood of flood openings flood openings? an attached of attached flood of flood openings flood openings? of the building if the 7 Certificate is being used to obtain flood 2292.00 sq ft or enclosure(s): or enclosure(s) openings in the crawlspace in A8.b or enclosure(s) 4740.00 sq in within 1.0 foot foot above adjacent in N/A sq ft x Yes ❑ No garage: garage openings in the attached garage within 1.0 in A9.b 0.00 sq ❑ Yes x No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number CITY OF CLEARWATER 125096 B2. County Name PINELLAS B3. State Florida B4. Map /Panel Number 12103C0106 B5. Suffix H B6. FIRM Index Date 08 -18 -2007 B7. FIRM Panel Effective/ Revised Date 05 -17 -2005 B8. Flood Zone(s) AE B9. Base Flood Elevation(s) (Zone AO, use Base Flood Depth) 12.0' BI0. Indicate the source ❑ FIS Profile B11. Indicate elevation B12. Is the building Designation Date: of the Base Flood Elevation ❑ Community Determined for BFE in Item B9: Coastal Barrier Resources (BFE) data or base flood ❑ Other /Source: depth entered in Item B9: x FIRM datum used located in a ❑ Other Protected /Source: • NGVD 1929 © NAVD 1988 System (CBRS) area or Otherwise CBRS ❑ OPA Area (OPA)? Yes x No FEMA Form 086 -0 -33 (7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660 -0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 406 VENETIAN DRIVE Policy Number: City State ZIP Code CLEARWATER Florida 33755 Company NAIC Number SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* x Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones A1—A30, AE, AH, A (with BFE), VE, V1 —V30, V (with BFE), AR, AR /A, AR /AE, AR /A1 —A30, AR /AH, AR /AO. Complete Items C2.a —h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: CLEARWATER B.M.# 1 -06 Vertical Datum: N.A.V.D. 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 x NAVD 1988 ❑ Other /Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 6.35 x feet ❑ meters b) Top of the next higher floor 17.45 x feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet ❑ meters d) Attached (top of slab) N/A ❑ feet ❑ meters garage e) Lowest elevation of machinery or equipment servicing the building 14.20 type location in Comments) x feet meters (Describe of equipment and f) Lowest adjacent (finished) grade next to building (LAG) 5.20 x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 6.30 x feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 5.50 structural support x feet meters SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? x Yes ❑ No x Check here if attachments. Certifier's Name License Number DONALD J. TRUCKENBROD 6505 , - a ,' Title - a Y ‘ PROFESSIONAL SURVEYOR AND MAPPER P . ce .• ,*, i Company Name' 4p? DJL SURVEYING CO., INC. `` ti t 0 • Address w` 05 a `�' 8324 CORPORATE WAY "; �" f= City State ZIP Code ! �# •'•••• 3,a NEW PORT RICHEY Florida 34653 igi ture Date Telephone Ext. 11 -13 -2018 (727) 845 -8084 Copy all pages of t is Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) ITEM A5.) THE DATA SHOWN TAKEN FROM GOOGLE EARTH. ITEM A8.b -d) CRAWL SPACE DOOR SYSTEM FLOOD VENTS MODEL #1616CS (1) VENT HAS A FLOW RATE FOR 395 SQUARE FEET OF THE ENCLOSURE FLOOR SPACE, THEY ALSO HAVE A REMOVAL EXTERIOR COVER. ITEM C2.e) THE LOWEST ELEVATION OF MACHINERY OR EQUIPMENT SERVICING THE BUILDING IS A ELECTRICAL METER CAN LOCATED ON THE LEFT SIDE OF THE BUILDING AND AFFIXED TO THE SIDE OF THE BUILDING, EL.(14.2). FEMA Form 086 -0 -33 (7/15) Replaces all previous editions. Form Page 2 o ELEVATION CERTIFICATE OMB No. 1660 -0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 406 VENETIAN DRIVE Policy Number: City State ZIP Code CLEARWATER Florida 33755 Company NAIC Number SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El—E5. If the Certificate is intended to support a complete Sections A, Band C. For Items E1 —E4, use natural grade, if available. Check the measurement enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters LOMA or LOMR -F request, used. In Puerto Rico only, the elevation is above or below ❑ above or ❑ below the HAG. ❑ above or ❑ below the LAG. 9 (see pages 1 -2 of Instructions), ❑ above or ❑ below the HAG. ❑ above or ❑ below the HAG. ❑ above or ❑ below the HAG. with the community's certify this information in Section G. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters E2. For Building Diagrams 6 -9 with permanent flood openings provided in Section A Items 8 and /or the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters E3. Attached garage (top of slab) is ❑ feet ❑ meters E4. Top of platform of machinery and /or equipment servicing the building is ❑ feet ❑ meters E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA- issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086 -0 -33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660 -0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 406 VENETIAN DRIVE Policy Number: City State ZIP Code CLEARWATER Florida 33755 Company NAIC Number SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 —G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA- issued or community- issued BFE) or Zone AO. G3. ❑ The following information (Items G4 —G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance /Occupancy Issued G7. This permit has been issued for: ❑ G8. Elevation of as -built lowest floor (including of the building: G9. BFE or (in Zone AO) depth of flooding at the G10. Community's design flood elevation: New Construction ❑ Substantial Improvement basement) ❑ feet ❑ feet ❑ feet ❑ meters Datum building site: ❑ meters Datum ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086 -0 -33 (7/15) Replaces all previous editions. Form Page 4 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS OMB No. 1660 -0008 See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 406 VENETIAN DRIVE Policy Number: City CLEARWATER State Florida ZIP Code 33755 Company NAIC Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. Photo One Photo One Caption FRONT VIEW 10/08/2018 Clear Photo One Photo Two Photo Two Caption REAR VIEW 10/08/2018 Clear Photo Two FEMA Form 086 -0 -33 (7/15) Replaces all previous editions. Form Page 5 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS Continuation Page OMB No. 1660 -0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 406 VENETIAN DRIVE Policy Number: City State ZIP Code CLEARWATER Florida 33755 Company NAIC Number If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. .ta( Photo Three Photo Three Caption RIGHT SIDE VIEW 10/08/2018 Clear Photo Three // J f 1 Photo Four Photo Four Caption LEFT SIDE VIEW 10/08/2018 Clear Photo Four FEMA Form 086 -0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 Certification of Engineered Flood Openings In accordance with the Code of Federal Regulations for the National Flood Insurance Program I hereby certify that the Crawl Space Door Systems flood vents 81642S,122005,1232(3, 1616C5,1624C5,1632CS, 2032:CS, 242405 and 2436CS are designed in accordance with the requirements of the Code of Federal Regulations for the National Flood Insurance Program (NFrP) to provide automatic equalization of hydrostatic flood forces by a owing for the entry and exit of floodwaters, when properly instiled and sized as set forth below. Vent opening measurements were measured and certified by Mr. Christopher Mark Loney, Virginia P.E. NO. 029000. Detailed calculations were prepared as outlined In "Review of certification of Engineered Food Openings," prepared by )r. Georg Reichard, Associate Professor of Building Construction, Virginia Tech (available upon request from Crawl Space Door Systems, Inc. billy@acmwtlspacedoors_com) Design Characteristics Section 2.6.2.2 of ASCE /SEI 24 -05 provides an equation to determine the required net area of engineered openings (A,) for a given enclosed area (Ae). This equation is based on the hydraulic formula for the flow rate across sharp edged orifices. I have utilized this equation to calculate 1) the restricted flow rate through the main frame opening in case the louver is blown out during a flood event; 2) the flow rate through the individual openings between louver blades; and 3) the flow rate through projected openings between louver blades following hydraulic short -tube theory. The maximum total enclosed area (/) that can be serviced by a single vent has then been determined by utilizing the lowest flow rate of the three assessed scenarios for each vent and is isted in Table 1. These values are based on the following assumptions: • In absence of reliable data, the rates of rise and fall have been assumed at a minimum rate of 5 feet/hour; • The (maximum) difference between the exterior and interior floodwater levels shall not exceed 1 foot during base flood conditions; • A factor of safety of 5 has been assumed, which is consistent with design practices related to protection of life and property; • The net area of openings (A,) as provided by the manufacturer. Installation Requirements and Limitations This certification will be voided if the following installation requirements and limitations are not enforced: • There shall be a minimum of two openings on different sides of each enclosed area subject to flooding; • The bottom of all openings shall be no higher than one foot above the higher of the interior or exterior grade that is immediately under each opening; • No temporary (e.g. during cold weather) or permanent solid cover may be placed into or over the flood vent that would block the automatic entry or exit of floodwaters at any time; • Where data or analyses indicate more rapid rates of rise and fall, the required number of openings shall be increased to account for those different conditions. The number or size of the openings may be decreased if data or analyses indicate rates of rise and fall are less than 5 feet per hour_ *) Model Fl X W iin) { Az Ae iz) iftzi J 816CS 8 x 16 105 205 _7 122005 12 x 20 235 500 i 173205 12 x 32 4 305 645 1616CS 16 x 16 ` 180 395 7 1624CS 16 x 24 310 670 163205 16 x 32 ` 405 835 D 2032CS 20 x 32 630 1240 2424CS 24 x 24 1 570 1230 `} 2436CS 24 x 36 850 1765 Table 1 Maximum total enclosed area -(Ae) that can be serviced by each individual model based an the given net area of engineered openings (A,) Certifying Design Professional Nome Steve A. Geci Title President company Geci & Associates Engineers, Inc. Address 2950 N 12th Avenue, Pensacola, FL 32503 License Florida License No. 33658 Signature: Date: Identification of the Building and installed Flood Vents (By Others) The flood vent models marked in Table 1 *) are being installed at the following building: Building Address Spring 2012 Ver. 2.0