Loading...
1076 ELDORADO AVEU.S. DEPARTMENT OF HOMELAND SECURITY FEDERAL EMERGENCY MANAGEMENT AGENCY National Flood Insurance Program ELEVATION CERTIFICATE Important: Read the instructions on pages 1-9. SECTION A - PROPERTY INFORMATION A1. Building Owner's Name THOMAS & ALISON NOVACK A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 1076 ELDORADO AVENUE City CLEARWATER BEACH, State FL ZIP Code 33767 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOTS 7, BLOCK 70, MANDALAY SUBDIVISION OMB No. 1660-0008 Expiration Date: July 31, 2015 A4. Building Use (e.g., Residential, Non-Residential, Addition, Accessory, etc.) RESIDENTIAL A5. Latitude/Longitude: Lat. 29 dea. 00' 17.6" Long. 82 dea. 49' 35.7" Horizontal Datum: ❑ NAD 1927 � NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 7 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) 2189 sq ft a) Square footage of attached garage N/A sq ft b) Number of permanent flood openings in the crawlspace b) Number of permanent flood openings in the attached garage or enciosure(s) within 1.0 foot above adjacent grade 6 within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b 702 sq in c) Total net area of flood openings in A9.b sq in d) Engineered flood openings? ❑ Yes � No d) Engineered flood openings? ❑ Yes ❑ No SECTION B- FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Communiry Number 62. County Name B3. State CLEARWATER / 125096 PINELLAS FLORIDA B4. Map/Panel Number 65. Suffix B6. FIRM Index Date B7. FIRM Panel B8. Flood 69. Base Flood Elevation(s) (Zone 12103 C 0064 G 08-18-09 Effective/Revised Date Zone(s) AO, use base flood depth) 09-03-03 VE 13' 610. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in item B9. ❑ FIS Profile � FIRM ❑ Communiry Determined ❑ Other/Source: 611. Indicate elevation datum used for BFE in Item 69: ❑ NGVD 1929 � NAVD 1988 ❑ OthedSource: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes � No Designation Date: ❑ CBRS ❑ OPA SECTION C- BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction" � Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones A1-A30, AE, AH, A(with BFE), VE, V1-V30, V(with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. tn Puerto Rico only, enter meters. Benchmark Utilized: CITY OF CLEARWATER J-02 Vertical Datum: 4.4385' Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ❑ NAVD 1988 � OthedSource: Datum used for building elevations must be the same as that used for the BFE. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) g) Highest adjacent (finished) grade next to building (HAG) h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support 5.7 14.5 12.5 5.7 7.1 5.1 5.8 N/A. Check the measurement used. � feet ❑ meters � feet ❑ meters � feet ❑ meters � feet ❑ meters � feet ❑ meters � feet ❑ meters � feet ❑ meters ❑ feet ❑ meters SECTION D- SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. � Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a � Check here if attachments. licensed land surveyor? � Yes ❑ No Certifier's Name LARRY L. EVANS Title LAND SURVEYOR Address 1460 BELTREES ST STE. 9 Signature Company Name City DUNEDIN, Date 02-13-2013 License Number PLS # 2937 EVANS LAND SURVEYING, INC. State FL ZIP Code 34698 Telephone (727) 734-3821 F_.,. k... ;�� �;�, �. �� R... `'� �`, .#'; � . ?ii $,:: FEMA Form 086-0-33 (7/12) See reverse side for continuation. Replaces all previous editions. ����r�� �v�� v���� �� �vr�� �� Maa�� � IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 1076 ELDORADO AVENUE City CLEARWATER BEACH, State FL ZIP Code 33767 FOR INSURANCE GOMPANY USE Policy Number: Company NAIC Number. SECTION D— SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agenUcompany, and (3) building owner. Comments C2.e): IS AN EXTERIOR A/C COMPRESSOR ON AN ELEVATED PAD. A8.c): VENT OPENINGS ARE 16" x 48", (768 sq. in. each), BUT ARE GREATLY RESTRICTED. (see photos) Signature Date 02-13-2013 SECTION E— BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A(WITHOUT BFE) For Zones AO and A(without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams Cr9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 8-9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F— PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A(without a FEMA-issued or community-issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address Signature Comments City Date State Telephone ZIP Code Check here if attachments. SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C(or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a buiiding located in Zone A(without a FEMA-issued or community-issued BFE) or Zone AO. G3. ❑ The following information (items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as-built lowest floor (inciuding basement) of the building: ❑ feet G9. BFE or (in Zone AO) depth of flooding at the building site: G10. Community's design flood elevation: Local Official's Name Community Name Signature Comments ❑ feet ❑ feet Title Telephone Date ❑ meters Datum ❑ meters Datum ❑ meters Datum Check here if attachments. FEMA Form 086-0-33 (7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 3 guilding Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 1076 ELDORADO AVENUE City CLEARWATER BEACH, State FL ZIP Code 33767 FOR INSURANCE COMPANY USE Policy Number: Company NAIC Number: If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. , ; �. _ -- — �,,,: f ■��� , �- � ��R� _ �' �� =tf � ' _� ' _ - --- — lilll lslFLl "_ __-- _ ��C::� erx�-, , ., - ._ __ . , �.�._ — _ _ _ =�aa.»� ..o- ....,. w, — ..i K., _ � � ��i�� ��I .,�, . �. ,_ � : .. ,� - FRONT VIEW 02-13-13 t;; ^ a`" ij ' IIi011 1�1���1��1� ^ _ -�. i� �� � � � FEMA Form 086-0-33 (7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 4 guilding Photographs Continuation Page IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 1076 ELDORADO AVENUE City CLEARWATER BEACH, State FL ZIP Code 33767 FOR INSURANCE COMPANY USE Policy Number: Company NAIC Number: If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. REAR VIEW 02-13-13 __ �---,..� . r��s� > =;x�. n,... , r„ � �o�w� � ��� j H �,���`�' �� � � #; � _ i ,,y. � � « .,:} � � � _ FEMA Form 086-0-33 (7/12) Replaces all previous editions. � _ - � . �- ` �h , , _ , _ �'� . ,,� ""� <. � . . :, ,. .. �....��� � �,: VENT CLOSE-UP 02-13-13