Loading...
PROPOSAL MARYMONT PARK IMPROVEMENTSin BANDES CONSTRUCTION 1 368 SPALDIN3 RD., STE. C, DUNEDIN, FL 34698-5039 P: (727) 733-5558 F: (727) 738-8225 LICENSE: # CG -0018550 Proposal Marvmont Park Improvements Thursday, August 28, 2025 Revision #1 TO: Craig Wilson, Parks Senior Division Manager City of Clearwater — Parks & Recreation 100 S Myrtle Ave, Clearwater, FL 33756 RE: MARYMONT PARK CITY OF CLEARWATER PARKS RECREATION DEPARTMENT PROJECT NUMBER XX As requested, enclosed is the proposal for renovations to the Marymont Park bathroom building and park shelter located at 1900 Gilbert St., Clearwater, FL 33765, submitted in accordance with scope directive and site visits with City staff for a Guaranteed Maximum Price of $170,384.75. Scope of Work: The following construction services will be provided under this contract: General • Perform two (2) design field visits to verify existing conditions in areas associated with the new work. • Produce measured drawings for existing building and shade structure affected by the new work. • Develop biddable and constructable Construction Documents in accordance with applicable code and permitting requirements. • Provide all permitting services required to complete the above-mentioned work, including inspection requests. Park Shelter • Provide structural engineering plans to renovate the park shelter. • Renovate the park shelter: sand, grind paint at all upright posts/columns and roof frame structure (color to match new playground color TBD). • Remove old and dispose of old park shelter roof and framing. Existing steel post and structure to remain in place for new timber beams, joists, and T&G decking. • Provide and install new timber framing shelter roof structure, pressure -treated SYP lumber and tongue & groove decking. • Provide a metal new roof to the park shelter. Restroom Building • Pressure wash the entire building and concrete pad under shelter and sidewalks around bathroom building. Including the roof. WWW.BANDESCONST.COM EQUAL OPPORTUNITY EMPLOYER • Remove and store all interior restroom plumbing fixtures for reinstallation and toilet accessories for reinstallation. • Remove all exterior doors and dispose of doors and hardware only. Frames to be re -used. • Remove and reinstall two toilets (needed for epoxy floor installation). Per Building & Maintenances Standard Fixture Specifications. • Grind and patch existing concrete roof, route & caulk all cracks, install sealant at all pipe penetrations, install Tremco 350/346 5 -year coating system to achieve watertight concrete roof system. • Provide all new impact -resistant exterior hollow metal doors, hinges, closers, and locks. All doors to be painted. Single door frame is to be replaced. All other door frames are in good condition and are to remain. • Lock keying to be by Owner. • Prep and sand finish stucco exterior of the restroom building. Stucco to be smooth as to allow for mural installation. • Prep and install medium coat of Conflex Ultracrete Acrylic Texture Coating on interior of restrooms. • Primer (1) coat, Paint (2) coats of exterior semigloss Sherwin Williams paint on exterior of restroom building. Color TBD. • Remove existing flooring and epoxy both restroom floors including 8" up the walls. Use specifications provided for Pier 60 Bait House. • Primer (1) coat, Paint (2) coats of interior semigloss Sherwin Williams paint interior of restrooms. Color TBD. • Install Men and Women ADA restroom signs on the exterior of the restroom doors. • Remove and reinstall all paper dispensers (toilet paper and hand towels) and soap dispensers. • Remove old sinks, faucets and plumbing and dispose of. • Existing floor -mounted urinal to remain. • Install new ODP stainless steel sinks with faucets including all necessary plumbing. • Remove existing switches and provide occupancy sensor switches in each restroom. • Provide new LED vandal -proof wall pack electrical fixture with photocell. Exclusions The following services are excluded from this proposal: • Civil Engineering or Landscape Architecture • HVAC • Power distribution upgrades • Panel metering • Electrical coordination and arc flash study • LEED documentation • Security and fire alarm design 2 • Hazardous materials assessment or abatement. No hazardous material or abatement is anticipated due to the cementitious and natural nature of the materials being worked on (concrete, wood, porcelain). Cost Detail: Division 1 Design & Engineering Bingham Architectural 11,550.00 General Conditions Bandes Construction 13,323.46 Pressure Washing Captain Bob 450.00 Division 2 Demolition Crue Construction 4,493.74 Division 3 Concrete Excluded 0.00 Division 4 Masonry - Grout in 1 Door Frame Bandes Construction 1,240.00 Division 6 Rough Carpentry Allowance 40,000.00 Division 7 Waterproofing General Caulking 13,500.00 Metal Roofing - Park Shelter Allowance 16,000.00 Division 8 Doors & Hardware Material Pinnacle Door 8,693.75 Doors & Hardware Labor Casey Stull 790.00 Keying By Owner 0.00 Division 9 Stucco Lorelei 10,500.00 Painting Ganster 2,250.00 Interior Texturing Ganster 400.00 Painting - Park Shelter Columns Allowance 400.00 Epoxy Flooring CFCS 4,678.04 Division 10 Toilet Accessories Reinstall Casey Stull 270.00 Toilet Accessories Material Reuse / By Owner 0.00 ADA Door Signs 2 Each 45.00 3 �B Division 15 Plumbing Clearwater Plumbing 2,475.00 Furnish New Water Closets Allowance 763.38 Furnish New Flush Valve at Urinal Allowance 427.00 Furnish New Sinks By Owner 0.00 Division 16 Electrical - LED Wall Pack FLA Electric 1,125.00 Electrical - Interior Switches FLA Electric 350.00 Subtotal 133,724.37 Builder's Risk Insurance 0.063% 84.25 General Liability Insurance 0.40% 534.90 Bond 1.204074% 1,610.14 CMAR Fee 15% 20,058.66 Permit Fees Allowance 1,000.00 Contingency 10% 13,372.44 Total 170,384.75 Schedule Detail Project to be substantially completed no later than December 31St, 2025. Existing Contract This proposal is submitted in conjunction with the existing Construction Manager at Risk Services Continuing Contract entered into with the City of Clearwater on 10/01/2024, based on RFQ #51-24. If GMP Exceeds $150,000 Per Section III, Article 5.1 of the Contract Specifications, the contractor shall provide to the public entity a certified copy of the recorded bond. Once the City receives a certified copy of the recorded bond, a Notice to Proceed may be issued. Include the attached bond form as well as the Power of Attorney. (If GMP is less than $150,000 a bond is not required.) 4 Approved as to form: BANDES CONSTRUCTION COMPANY, INC. By: Zachary Bandes Vice President 08/28/2025 Date CITY OF CLEARWATER, FLORIDA By: MclissA 1 e11 Senior Assistant City Attorney Countersigned: Bruce R Mayor Date 1(Z7 �2a ZS Attest: Rosemarie Call City Clerk Date 5 enni'l Porrier City Manager