Loading...
24 AVALON STU.S'. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. OMB No. 1660-0008 Expiration Date: November 30, 2022 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name AVALON CLUB, LLC Policy Number: A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Company NAIC Number: City State ZIP Code CLEARWATER Florida 33767 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) PARCEL ID# 05-29-15-16362-006-0070 CLEARWATER BEACH REV BLK 6, LOTS 7, 8, 11 & 12 & S 62FT OF LOT 10 A4. Building Use (e.g., A5. Latitude/Longitude: A6. Attach at least A7. Building Diagram A8. For a building a) Square footage b) Number of permanent c) Total net area d) Engineered A9. For a building with a) Square footage b) Number of permanent c) Total net area d) Engineered Residential, Non -Residential, Addition, Accessory, etc.) • Lat. 27'59'11.1" N Long. 82°49'37.3" W RESIDENTIAL Horizontal Datum: insurance. above ❑ NAD 1927 adjacent grade grade 0 x NAD 1983 21 2 photographs Number with a crawlspace of crawlspace flood of flood openings flood openings? an attached of attached flood of flood openings flood openings? of the building if the 6 Certificate is being used to obtain flood 3526.35 sq ft or enclosure(s): or enclosure(s) openings in the crawlspace in A8.b or enclosure(s) 4200.00 sq in within 1.0 foot foot above adjacent in 0.00 sq ft x Yes ❑ No garage: garage openings in the attached garage within 1.0 in A9.b 0.00 sq ❑ Yes x No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number CITY OF CLEARWATER; 125096 B2. County Name PINELLAS B3. State Florida B4. Map/Panel Number 12103C0102 B5. Suffix G B6. FIRM Index Date 08-18-2009 B7. FIRM Panel Effective/ Revised Date 09-03-2003 B8. Flood Zone(s) AE B9. Base Flood E evation(s) (Zone AO, use Base Flood Depth) 11 FEET, 12 FEET B10. Indicate the source ❑ FIS Profile B11. Indicate elevation B12. Is the building Designation of the Base Flood Elevation ❑ Community Determined for BFE in Item B9: Coastal Barrier Resources ❑ (BFE) data or base flood ❑ Other/Source: ❑ NGVD 1929 System (CBRS) CBRS ❑ OPA depth entered in Item B9: 41 x FIRM datum used located in a Date: ❑ Other/Source: Protected x NAVD 1988 area or Otherwise Area (OPA)? ❑ Yes x No FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 1 of 6 Atlas #: 258, 24 AVALON ST BCP2019-08051 OC COMP EC AVALON CLUB LLC Zoning: Medium High Density IiitSt; i'LANS FOR CODE COMPLIANCE BY THE CITY OF CLEARWATER AND ARE SUBJECT TO FIELD VERIFICATION BY CITY INSPECTORS BY: DATE: i U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. OMB No. 1660-0008 Expiration Date: November 30, 2022 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name AVALON CLUB, LLC Policy Number: A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Company NAIC Number. City State ZIP Code CLEARWATER Florida 33767 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) PARCEL ID# 05-29-15-16362-006-0070; CLEARWATER BEACH REV BLK 6, LOTS 7, 8, 11 & 12 & S 62FT OF LOT 10 A4. Building Use (e.g., A5. Latitude/Longitude: A6. Attach at least A7. Building Diagram A8. For a building a) quare footage b) Number of permanent c) Total net area d) Engineered A9. For a building with a) Square footage b) Number of permanent c) Total net area d) Engineered Residential, Non -Residential, Addition, Accessory, etc.) . Lat.27°59'11.1" N Long. 82°49'37.3" W RESIDENTIAL Horizontal Datum: insurance. above ❑ NAD 1927 adjacent grade grade 0 x NAD 1983 21 2 photographs Number with a crawlspace of crawlspace flood of flood openings flood openings? an attached of attached flood of flood openings flood openings? of the building if the 6 Certificate is being used to obtain flood 3526.35 sq ft or enclosure(s): or enclosure(s) openings in the crawlspace in A8.b or enclosure(s) 4200.00 sq in within 1.0 foot foot above adjacent in 0.00 sq ft x Yes ❑ No garage: garage openings in the attached garage within 1.0 in A9.b 0.00 sq ❑ Yes x No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number CITY OF CLEARWATER; 125096 B2. County Name PINELLAS B3. State Florida B4. Map/Panel Number 12103C0102 65. Suffix G B6. FIRM Index Date 08-18-2009 B7. FIRM Panel Effective/ Revised Date 09-03-2003 B8. Flood Zone(s) AE B9. Base Flood Elevation(s) (Zone AO, use Base Flood Depth) 11 FEET. 12 FEET B10. Indicate the source ❑ FIS Profile B11. Indicate elevation B12. Is the building Designation Date: of the Base Flood Elevation ❑ Community Determined for BFE in Item B9: Coastal Barrier Resources ❑ (BFE) data ❑ NGVD System CBRS or base flood ❑ Other/Source: depth entered in Item B9: x FIRM datum used located in a ❑ Other/Source: Protected 1929 x NAVD 1988 (CBRS) area or Otherwise ❑ OPA Area (OPA)? ❑ Yes x No FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Policy Number: City State ZIP Code CLEARWATER Florida 33767 Company NAIL Number SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* x *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones A1—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, Benchmark Utilized: SEE NOTE Vertical Datum: 5.51 FEET NAVD88 Finished Construction AR/AH, AR/AO. enter meters. Indicate elevation datum ❑ NGVD 1929 used x for the elevations in items a) through h) below. NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 7.5 x the measurement used. feet ❑ meters b) Top of the next higher floor 17.4 x feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A x feet ❑ meters d) Attached garage (top of slab) 7.0 x feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 17,9 x (Describe type of equipment and location in Comments) feet ❑meters f) Lowest adjacent (finished) grade next to building (LAG) 5.3 x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 7.4 x feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support 4.8 x feet ❑ meters SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect I certify that the information on this Certificate represents my best efforts to interpret statement may be punishable by fine or imprisonment under 18 U.S. Code, Section Were latitude and longitude in Section A provided by a licensed land surveyor? x authorized by law to certify elevation information. the data available. I understand that any false 1001. Yes ❑ No ❑ Check here if attachments. Certifier's Name License Numberos DANA A. WYLLIE LS 5874bc (t.! �/ " 4 -I ,)'Y J _\q5:11)‘ Title PROFESSIONAL SURVEYOR AND MAPPER Company Name DEUEL & ASSOCIATES WO#2019-202 (TBM) Address 565 SOUTH HERCULES AVENUE\\ill:. Cit State City ZIPCode CLEARWATER Florida 33764 Signare �....,C _ Date Telephone Ext. 06-07-2021 (727) 822-4151 214 Copy all pages of this Elevation Cecate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) DATE TYPED IN SECTION D IS THE DATE OF THE FIELD SURVEY. A5: LATITUDE AND LONGITUDE WERE DETERMINED USING GOOGLE EARTH. A8: TOTAL NET AREA OF FLOOD VENTS ACCOUNTS FOR CERTIFIED COVERAGE FOR ENGINEERED VENTS (SEE PHOTOS). C2: BENCHMARK ELEVATION SHOWN IS BASED ON NAVD88 PER CONSTRUCTION PLANS FOR AVALON BEACH CLUB PREPARED BY NORTHSIDE ENGINEERING, INC., CLEARWATER, FLORIDA, DATED: 9/03/2019. SECOND FLOOR FINISHED FLOOR ELEVATION = 17.4 FEET. COMMENTS CONTINUE ON NEXT SHEET... FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Sfreet Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Policy Number: City State ZIP Code CLEARWATER Florida 33767 Company NAIC Number SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl . Building elevations are based on: ❑ Construction Drawings* *A new Elevation Certificate will be required when construction of the C2. Elevations — Zones A1—A30, AE, AH, A (with BFE), VE, V1—V30, V Complete Items C2.a—h below according to the building diagram specified Benchmark Utilized: N/A Vertical II building (with Datum: Building Under Constructio is complete. BFE), AR, ARIA, A AE, AR/A1—A30, in Item A7. In P rto Rico only, N/A �� x Finished Construction AR/AH, AR/AO. enter meters. Indicate elevation datum ❑ NGVD 1929 used x for the elevations in items a) through h) below. 0� NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BF . II Check a) Top of bottom floor (including basement, crawlspace, or enclosure f o r) N/A x the measurement used. feet ❑ meters b) Top of the next higher floor isl1/4' N/A x feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones o• y) N/A x feet ❑ meters V d) Attached garage (top of slab) N/A x feet meters e) Lowest elevation of machinery or equipment servicing e building Q N/A (Describe type of equipment and location in Comme• s) x feet ❑meters f) Lowest adjacent (finished) grade next to buildin. AG) N/A x feet ❑ meters g) Highest adjacent (finished) grade next to bui = ng (HAG) N/A x feet ❑ meters h) Lowest adjacent grade at lowest elevatioof deck or stairs, including structural support N/A x feet ❑ meters SECTION D — d RVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and se. •d by a land surveyor, engineer, or architect I certify that the information on this Cer ificate represents my best efforts to interpret statement may be punishable by fin- .r imprisonment under 18 U.S. Code, Section Were latitude and longitude in Se, on A provided by a licensed land surveyor? x , authorized by law to certify elevation information. the data available. I understand that any false 1001. Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number DANA A. WYLLIE LS 5874 Title PROFESSIONAL SU EYOR AND MAPPER Company Name DEUEL & ASSOC TES WO#2019-202 (TBM) Address 565 SOUTH , RCULES AVENUE City State ZIP Code CLEAR ATER Florida 33764 Signa re Date Telephone Ext. 04-21-2021 (727) 822-4151 214 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) C2a: ELEVATION SHOWN IS THE TOP OF SLAB ON GRADE IN LOBBY. -. C2d: ELEVATION SHOWN IS TOP OF GRAINAGE GRATE IN GARAGE'S SLAB ON GRADE. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page.... ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Badding Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Policy Number: City State ZIP Code CLEARWATER Florida 33767 Company NAIC Number SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters LOMA or LOMR-F request, used. In Puerto Rico only, the elevation is above or below ❑ above or ❑ below the HAG. ❑ above or ❑ below the LAG. 9 (see pages 1-2 of Instructions), ❑ above or ❑ below the HAG. ❑ above or ❑ below the HAG. ❑ above or ❑ below the HAG. with the community's this information in Section G. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters E3. Attached garage (top of slab) is ❑ feet ❑ meters E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Policy Number: City State ZIP Code CLEARWATER Florida 33767 Company NAIC Number SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ G8. Elevation of as -built lowest floor (including of the building: G9. BFE or (in Zone AO) depth of flooding at the G10. Community's design flood elevation: New Construction ❑ Substantial Improvement basement) ❑ feet ❑ feet ❑ feet ❑ meters Datum building site: ❑ meters Datum ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 4 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS See Instructions for Item A6. OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Policy Number: City State ZIP Code CLEARWATER Florida 33767 Company NAIC Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. 4 11111111 �" �' _ A. l h Photo One Photo One Caption FRONT VIEW (EAST SIDE - 6/7/2021) Clear Photo One f 4 1 ;�n,n, 010111010. 10$01.10011110 4dr sp moo, iw0- st..a y • gi O pe ,;10240 110 0111 I y _ I Photo Two Photo TWO Photo Two Caption REAR VIEW (WEST SIDE - 6/7/2021) Clear FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 5 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS Continuation Page OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt.; Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Policy Number: City State ZIP Code CLEARWATER Florida 33767 Company NAIC Number If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. .,0 0 - -';': ,..,;:,_ k , t Fill t. 1 '# ;t ,,,..�,�,�. e • i Three . aillialiallaft,. rye• a. Photo Photo Three Caption LEFT SIDE VIEW (SOUTH SIDE - 6/7/2021) Clear Photo Three Ilk II _ .. :: :,f�r+'jrnu:il� ... -.1: ��." •.r!—: •••• .. Photo r rrrrr - yNr pr q r. on �i'r'iit� J 1!irr fp jJJij ' ,t _ + i ■`r • 0I+N„ ' �^ertE-1 sp Four • �� Photo Four Caption RIGHT SIDE VIEW (NORTH SIDE - 6/7/2021) Clear Photo Four FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 6 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS See Instructions for Item A6. OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 24 AVALON STREET Policy Number: City State ZIP Code CLEARWATER Florida 33767 Company NAIC Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. �T's3y :' ! t C'1 et t Nat., *nC t:-: 14:34r: . '.+.am4trt.ratt.a..tn I.877-441406$ t .-rt tiled it. cow, 2100sgfft N, / (410 t I5.4 b+.ttt 1 ::*-4 ". F S_1.t.,�r.=4fSN I Alit. in Ow 1 ;.i Photo One Photo One Caption ENGINEERED FLOOD VENT INFO PLATE (4/27/2021) Clear Photo One \ / Photo TAO Photo Two Caption ENGINEERED FLOOD VENT (7/12/2021) Clear Photo Two FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 5 of 6 RECEIVED BY: C.R. JUL 13 2021 PLANNING & DEVELOPMENT CITY OF CLEARWATER 24 AVALON ST BCP2019-080510C AVALON CLUB AVALON CLUB LLC Zoning: Medium High Density Atlas #: 258A RECEIVED BY: C.R. JUL 13 2021 PLANNING & DEVELOPMENT CITY OF CLEARWATER 24 AVALON ST BCP2019-080510C AVALON CLUB AVALON CLUB LLC Zoning: Medium High Density Atlas #: 258A RECEIVED BY: C.R. JUL 13 2021 PLANNING & DEVELOPMENT CITY OF CLEARWATER 24 AVALON 5 �C BCP2019-080 AVALON CLUB AVALON CLUB LLC Zoning: Medium High Density Atlas #: 258A RECEIVED BY: C.R. JUL 13 2021 PLANNING & DEVELOPMENT CITY OF CLEARWATER 24 AVALON ST BCP2019-080510C AVALON CLUB AVALON CLUB LLC Zoning: Medium High Density Atlas #: 258A ES ICC EVALUATION SERVICE ICC -ES Evaluation Report ICC -ES 1 (800) 423-6587 1 (562) 699-0543 1 www.icc-es.org Most Widely Accepted and Trusted ESR -2074 Reissued 02/2021 Reused 04/2021 This report is subject to renewal 02/2023. DIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 ICC ICC Q -ES PMG � LISTED "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" A Subsidiary of ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright c 2021 ICC Evaluation Service, LLC. All rights reserved. ICC MEI EVALUATION SERVICE` ICC -ES Evaluation Report ESR -2074 Reissued February 2021 Revised April 2021 This report is subject to renewal February 2023. -, 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540- 511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 EVALUATION SCOPE Compliance with the following codes: • 2021, 2018, 2015, 2012, 2009 and 2006 International Building Code® (IBC) • 2021, 2018, 2015, 2012, 2009 and 2006 International Residential Code® (IRC) • 2021, 2018 International Energy Conservation Code® (IECC) • 2013 Abu Dhabi International Building Code (ADIBC)t tThe ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: • Physical operation • Water flow 2.0 USES The Smart Vent® units are engineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure on walls of enclosures subject to rising or falling flood waters. Certain models also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: When subjected to rising water, the Smart Vent® FVs internal floats are activated, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The FV pivoting door is normally held in the closed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the door to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. Smart Vent® Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SmartVENT® Stacking Model #1540-511 and FloodVENT® Stacking Model #1540- 521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The FVs comply with the design principle noted in Section 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 ofASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs must be installed in accordance with Section 4.0. 3.3 Ventilation: The SmartVENT® Model #1540-510 and SmartVENT® Overhead Door Model #1540-514 both have screen covers with 1/4 -inch -by -1/4 -inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENT® Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to supply natural ventilation. Other FVs described in this report do not offer natural ventilation. 3.4 Flood Vent Sealing Kit: The Flood Vent Sealing Kit Model #1540-526 is used with SmartVENT® Model #1540-520. It is a Homasote 440 Sound Barrier® (ESR -1374) insert with 21 – 2 -inch -by -2 -inch (51 mm x 51 mm) squares cut in it. See Figure 4. 4.0 DESIGN AND INSTALLATION 4.1 SmartVENT® and FloodVENT®: SmartVENT® and FloodVENT® are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. Installation clips allow mounting in masonry and concrete walls of any thickness. In order to comply with the engineered opening design principle noted in Section 2.7.2.2 and 2.7.3 of ASCE/SEI 24- 14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the Smart Vent® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically' addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 5 iu CrD ESR -2074 Most Widely Accepted and Trusted • With a minimum of one FV for every 200 square feet (18.6 m2) of enclosed area, except that the SmartVENT® Stacking Model #1540-511 and FloodVENT® Stacking Model #1540-521 must be installed with a minimum of one FV for every 400 square feet (37.2 m2) of enclosed area. • Below the base flood elevation. ■ With the bottom of the FV located a maximum of 12 inches (305.4 mm) above the higher of the final grade or floor and finished exterior grade immediately under each opening. 4.2 Flood Vent Sealing Kit The Flood Vent Sealing Kit Model 1540-526 is used in conjunction with FloodVENT® Model #1540-520. When installed and tested in accordance with ASTM E283, the FV and Flood Vent Sealing Kit assembly have an air leakage rate of less than 0.2 cubic feet per minute per lineal foot (18.56 1/min per lineal meter) at a pressure differential of 1 pound per square foot (50 Pa) based on 12.58 lineal feet (3.8 lineal meters) contained by the Flood Vent Sealing Kit, 5.0 CONDITIONS OF USE The Smart Vent® FVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Smart Vent® FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report govern. Page 2 of 5 5.2 The Smart Vent® FVs must not be used in the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC -ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015 (editorially revised February 2021). 6.2 Test report on air infiltration in accordance with ASTM E283. 7.0 IDENTIFICATION 7.1 The Smart VENT® models and the Flood Vent Sealing Kit described in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc.), the model number, and the evaluation report number (ESR -2074). 7.2 The report holder's contact information is the following: SMART VENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441-8368 www.smartvent.corn infol smartvent.com TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) FloodVENT® 1540-520, 153/4" X 73/4" 200 SmartVENT® 1540-510 153/4" X 73/4" 200 FloodVENT® Overhead Door 1540-524 153/4" X 73/4" 200 SmartVENT® Overhead Door 1540-514 153/4" X 73/4" 200 Wood Wall FloodVENT® 1540-570 14" X 83/4" 200 Wood Wall FloodVENT® Overhead Door 1540-574 14" X 83/4" 200 SmartVENT® Stacker 1540-511 16" X 16" 400 FloodVent® Stacker 1540-521 16" X 16" 400 For SI: 1 inch = 25.4 mm; 1 square foot = m2 ■ar:!■■:.:iiii *:r*UIararar ••1=1i a t+.iiii lltifiai a 'iiia • ■ �r•l 1. JI.V 'le s. iaai■araraaiaiaaa as: •,_.•.-.,aaaaa= .sy v ■. 1-1-Jerr.vir a Eli gangLi ■aii3a i. ........... rrrOraag ^'a • _• ilivaa uaoaaara9faii..i'aric�a-- eullrri= r ...e/ ar.r,f. i 1 r■ ra sis ■ : :1 =rszo-a azzaaazz FIGURE 1—SMART VENT: MODEL 1540-510 ESR -2074 Most Widely Accepted and Trusted Page 3 of 5 FIGURE 2—SMART VENT MODEL 1540-520 FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN FIGURE 4 -FLOOD VENT SEALING KIT ES ICC EVALUATION SERVICE' ICC -ES Evaluation Report ESR -2074 CBC and CRC Supplement Reissued February 2021 Revised April 2021 This report is subject to renewal February 2023. 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540511; #1540- 570; #1540574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent° Automatic Foundation Flood Vents, described in ICC -ES evaluation report ESR -2074, have also been evaluated for compliance with codes noted below. Applicable code editions: • 2019 California Building Code (CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) and Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below. • 2019 Califomia Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The Smart Vent° Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation report ESR -2074, comply with 2019 CBC Chapter 12, provided the design and installation are in accordance with the 2018 International Building Code° (IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapters 12 and 16 , as applicable. 2.1.1 OSHPD: The applicable OSHPD Sections and Chapters of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections and Chapters of the CBC are beyond the scope of this supplement. 2.2 CRC: The Smart Vent° Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation report ESR -2074, comply with the 2019 CRC, provided the design and installation are in accordance with the 2018 International Residential Code® (IRC) provisions noted in the evaluation report. This supplement expires concurrently with the evaluation report, reissued February 2021 and revised April 2021. ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as its to any finding or other matter in this report, or as to any product covered by the report. atm Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 4 of 5 ES ICC EYAI. DATION SERVICE' ICC -ES Evaluation Report ESR -2074 FBC Supplement Reissued February 2021 Revised April 2021 This report is subject to renewal February 2023. 4-2 s_Lrr .1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents, described in ICC -ES evaluation report ESR -2074, have also been evaluated for compliance with the codes noted below. Applicable code editions: • 2020 Florida Building Code—Building • 2020 Florida Building Code—Residential 2.0 CONCLUSIONS The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation report ESR -2074, comply with the Florida Building Code—Building and the Florida Building Code -Residential , provided the design requirements are determined in accordance with the Florida Building Code -Building or the Florida Building Code -Residential, as applicable. The installation requirements noted in ICC -ES evaluation report ESR -2074 for 2018 International Building Code® meet the requirements of the Florida Building Code -Building or the Florida Building Code -Residential, as applicable. Use of the Smart Vent® Automatic Foundation Flood Vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building Code—Residential . For products falling under Florida Rule 61G20-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the evaluation report, reissued February 2021 and revised April 2021. /CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed., as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ii,"11511 to any finding or other matter in this report, or as to any product covered by the report. lir. Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 5 of 5 " BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report of Smart Vent Products, Inc. Insulated Flood Vent Model #1540-520 insulated Stacked Flood Vent Model #1540-521 Dual Function Smart Vent Model #1540-510 Dual Function Stacked Smart Vent Model #1540-511 Insulated Wood Wall Flood Vent Model #1540-570 for Florida Product Approval FL# FL5822 Report No. 5022 Current Florida Building Code Method: Category: Sub — Category: Other Sub -Category: Product: Material: Product Dimensions: 2 — B (Engineering Evaluation) Structural Components Products Introduced as a Result of New Technology Ventilation Automatic Foundation Flood Vents (AFFV) Stainless Steel See Installation Instructions Prepared For: Smart Vent Products, Inc. 430 Andbro Drive, Unit 1 Pitman, NJ 08071 Prepared by: Hermes Norero, P.E. Florida Professional Engineer # 73778 Date: 06/15/2018 Contents: Evaluation Report Pages 1— 3 Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date. 2018.06.20 07:22:36 -04'00' * 0 Herru44NbteOb; P.E. Florida No. 73778 /\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 FL#: FL5822 Date: 06/15/2018 Report No: 5022 Manufacturer: Smart Vent Products, Inc. Product Category: Structural Components Product Sub -Category: Other Other Sub -Category: Ventilation Compliance Method: State Product Approval Method (2)(b) Product Name: Insulated Flood Vent Model #1540-520 Scope: Limits of Use: nsulated Stacked -foo. Vent Model #1540-521 Dual Function Smart Vent Model #1540-510 Dual Function Stacked Smart Vent Model #1540-511 Insulated Wood Wall Flood Vent Model #1540-570 This is a Product Evaluation Report issued by Hermes Norero, P.E. (FL # 73778) for Smart Vent Products, Inc. based on Rule Method 2b of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions provided by Smart Vent Products, Inc., verified by Hermes Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of the drawings require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations. 6. Wall construction shall meet requirements of Section 1612 of the FBC as deemed technically relevant due to site conditions. Hermes Norero, P.E. Florida No. 73778 Page 2 of 3 /\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 FL#: FL5822 Date: 06/15/2018 Report No: 5022 Quality Assurance: The manufacturer has demonstrated compliance of ventilation products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through Architectural Testing, Inc. (FBC Organization #: QUA 1844) Performance Standards: The product described herein has been evaluated and tested per: • ASTM E 330-02 • ASCE 24-14 • TAS 202-94 Code Compliance: The product described herein complies with the current FBC Section 1708.2 and the intent of the current Edition FBC Section 1612.5(1)(1.2). Referenced Data: 1. Product Testing performed by Architectural Testing, Inc. (FBC Organization # TST1558) Report #: 01-42966.01, Report Date: 11/15/02 Report #: 38957.102-122-44, Report Date: 11/16/05 Report #: 60619.01-122-47, Report Date: 11/16/05 Report #: 61877.01-122-44, Report Date: 01/06/06 Report #: 94135.01-109-18, Report Date: 08/31/09 Signed and Sealed by: Michael D. Stremmel, P.E. FL # 65868 2. Product Testing performed by Blackwater Testing, Inc. (FBC Organization # TST10394) Report #: BT -SVP -16-001, Report Date: 01/06/17 Signed and Sealed by: Constantine Bortes, P.E. FL # 77915 3. Quality Assurance Architectural Testing, Inc. (FBC Organization #: QUA 1844) 4. ICC Evaluation Service ESR -2074: Meets requirements of AC364 Reissued February 2017 Revised November 2017 Installation: Refer to Installation Instructions by Manufacturer for installation requirements. Design Pressure: Design Pressures +100/-100 PSF Hermes Norero, P.E. Florida No. 73778 Page 3 of 3