Loading...
380 WINDWARD PSGEr U.S. DEPARTMENT OF HOMELAND SECURITY Fedp'rai Emt.tgency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. OMB No. 1660-0008 Expiration Date: November 30, 2022 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name STEPHEN J AND LINDSAY E. DVORAK Policy Number: A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 380 Windward Passage Company NAIC Number: City State ZIP Code Clearwater Florida 33767 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 69 - Unit 1 Island Estates of Clearwater- Plat Book 44, Pages 62&63 - Parcel #08-29-15-43308-000-0690 A4. Building Use (e.g., A5. Latitude/Longitude: A6. Attach at least A7. Building Diagram A8. For a building a) Square footage b) Number of permanent c) Total net area d) Engineered A9. For a building with a) Square footage b) Number of permanent c) Total net area Residential, Non -Residential, Addition, Accessory, etc.) Lat, 27.97749°N Long. 82.81443°W Residential Horizontal Datum: insurance. above ❑ NAD 1927 adjacent grade grade 4 x NAD 1983 0 2 photographs Number with a crawlspace of crawlspace flood of flood openings flood openings? an attached of attached flood of flood openings flood openings'? of the building if the 1B Certificate is being used to obtain flood 0.00 sq ft or enclosure(s): or enclosure(s) openings in the crawlspace in A8.b or enclosure(s) 0.00 sq in within 1.0 foot foot above adjacent in 687.00 sq ft ❑ Yes x No garage: garage openings in the attached garage within 1.0 in A9.b 800.00 sq -.-="--- d) Engine ed x Yes ❑ No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION \--\ B1. NFIP Community Name & Community Number Clearwater - 125096 B2. County Name Pinellas B3. State Florida B4. Map/Panel Number 12103C0102 B5. Suffix G B6. FIRM Index Date 08-18-2009 B7. FIRM Panel Effective/ Revised Date 09-03-2003 B8. Flood Zone(s) AE B9. Base Flood E evation(s) (Zone AO, use Base Flood Depth) 11.0' B10. Indicate the source ❑ FIS Profile B11. Indicate elevation B12. Is the building Designation of the Base Flood Elevation ❑ Community Determined for BFE in Item B9: Coastal Barrier Resources ❑ (BFE) data or base flood ❑ Other/Source: ❑ NGVD 1929 System (CBRS) CBRS ❑ OPA depth entered in Item B9: x FIRM datum used located in a Date: ❑ Other/Source: Protected x NAVD 1988 area or Otherwise Area (OPA)? ❑ Yes x No FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 380 Windward Passage Policy Number: City State ZIP Code Clearwater Florida 33767 Company NAIC Number SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* Finished Construction x *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones A1 -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: City of Clearwater Map #H -04A Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 x NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawispace, or enclosure floor) 13.0 x feet ❑ meters b) Top of the next higher floor feet ❑ meters N/A x c) Bottom of the lowest horizontal structural member (V Zones only) feet ❑ meters N/A x d) Attached garage (top of slab) feet ❑ meters 6.2 x e) Lowest elevation (Describe of machinery or equipment servicing the building 13.1 type of equipment and location in Comments)❑ feet meters x f) Lowest adjacent (finished) grade next to building (LAG) 5.5 x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) feet ❑ meters 6.0 x h) Lowest adjacent structural grade at lowest elevation of deck or stairs, including support feet ❑ meters 6.0 x SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to he signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. f understand that any false statement maybe punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? X Yes ❑ No x Check here if attachments. Certifier's Name License Number John O. Brendla 4601 Title \ Surveyor 1 Company Name John C. Brendla & Associates, Inc. Address 4015 82nd Avenue North ere Pinellas Park Florida 337 lode 6)5- ,70 Signature 05 1 Telephone Ext. 0-Y)/� f1/ 'Da / e 05 11 2021 (727) 576-7546 None Copy all ages 'f this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comme s (in uding type of equipment and location, per C2(e), if applicable) C2) e. A/ -ckets located on the West side of the house NOTE: There are 4 Smart Vents in the Garage Model #1540-520 @ 200 square inch per vent for a total of 800 square inches The Photos are the attachments Benchmark: City of Clearwater Designation H -04A Elev. 4.5713' NAVD - MSL = 0.00 FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 2 of 6 1 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 380 Windward Passage Policy Number: .City State ZIP Code Clearwater Florida 33767 Company NAIC Number SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a complete Sections A, Band C. For Items E1—E4, use natural grade, if available. Check the measurement enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters LOMA or LOMR-F request, used. In Puerto Rico only, the elevation is above or below ❑ above or ❑ below the HAG. ❑ above or ❑ below the LAG. 9 (see pages 1-2 of Instructions), ❑ above or ❑ below the HAG. ❑ above or ❑ below the HAG. ❑ above or ❑ below the HAG. with the community's certify this information in Section G. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters E3. Attached garage (top of slab) is ❑ feet ❑ meters E4. Top of platform of machinery and/or equipment servicing the building is _ ❑ feet ❑ meters E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments 380 WINDWARD P/ BCP2020-040680B FINISHED EC DVORAK, STEPHEN 0 Zoning: Island Estates Atla: -I_. ,;. IN DL D. "/4 i Y Ci EL,: , i I_ ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 380 Windward Passage Policy Number: City State ZIP Code Clearwater Florida 33767 Company NAIC Number SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ G8. Elevation of as -built lowest floor (including of the building: G9. BFE or (in Zone AO) depth of flooding at the G10. Community's design flood elevation: ❑ feet ❑ feet ❑ feet New Construction • Substantial Improvement basement) • meters Datum building site: ❑ meters Datum ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) 380 WINDWARD PASS BCP2020-040680B FINISHED EC DVORAK, STEPHEN Zoning: Island Estates Atlas #: 267B ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 4 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS See Instructions for Item A6. OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 380 Windward Passage Policy Number: City State ZIP Code Clearwater Florida 33767 Company NAIC Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. w of - - a_ _ '- ':-.1:1! J_ a'a, -- x MO FRONT i ��^Y ate. -.ow.. r Clear Photo One BACK 11i • +t - -• _. Y _ 23/04/2021 20:23:._.'`r�;. Photo Two Caption Clear Photo Two FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 5 of 6 • ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS Continuation Page IMPORTANT: In these spaces, copy the corresponding information from Section A. OMB No. 1660-0008 Expiration Date: November 30, 2022 FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 380 Windward Passage Policy Number: City Clearwater State Florida ZIP Code 33767 Company NAIC Number If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View' and Rear View and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. Photo Four Photo Four VENT Clear Photo Three Photo Four Caption FEMA Form 086-0-33 (12/19) Replaces all previous editions. Clear Photo Four Form Page 6 of 6 6/1/2021 Florida Building Code Online d�pr BCIS Home Log In User Registration Product Approval USER: Public User Hot Topics Submit Surcharge Stats & Facts Product Approval Menu > Product or AQplication Search > AQQlicdtion List > Application Detail FL # Application Type Code Version Application Status Comments Archived Publications FL5822-R8 Affirmation 2020 Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Product Manufacturer Smart Vent Products, Inc. Address/Phone/Email 430 Andbro Dr Unit 1 Pitman, NJ 08071 (877) 441-8368 info@smartvent.com Authorized Signature Michael Graham info@smartvent.com Technical Representative Michael Graham Address/Phone/Email 430 Andbro Dr Unit 1 Pitman, NJ 08071 (877) 441-8368 info@smartvent.com Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method RECEIVED BY: C.R. JUN 0 1 2021 PLANNING & DEVELOPMENT CITY OF CLEARWATER Structural Components Products Introduced as a Result of New Technology Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Hermes F. Norero P.E. Evaluation Report Florida License PE -73778 Quality Assurance Entity Architectural Testing, Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2023 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL5822 R8 COI Smart Vent COI 55 2017-08-18 .pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 380 WINDWARD PASS BCP2020-040680B NEW SF HOME DVORAK, STEPHEN Zoning: Island Estates 0 Atlas #: 267B www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvMdF6zR4iHLm1meckcmccEdXH7GOGk3yg%3d 1/3 6/1/2021 Florida Building Code Online I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No N/A FL5822 R8 COC 5A5822 5httefVfb BY: C.R. Product Approval Method Method 2 Option B Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL 5822.1 12/16/2020 12/16/2020 JUN 01 2021 12/28/2020 PLANNING & DEVELOPMENT CITY OF CLEARWATER Model, Number or Name SmartVent Model #1540-510 Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). 5822.2 Description Dual Function Flood and Ventilation Vent Installation Instructions FL5822 R8 I1 1540-510 SS 2017-08-23.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R8 AE PER5022 SS 2018-06-20.p_df FL5822 R8 AE SmartVent -Im•• R-• _ir-m n _ r17 08-2iodf 1 r•.eated by Independent Third Party: Yes SmartVent Model #1540-511 Limits of Use Approved for use in HVHZ: Ye Approved for use outside HVIZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 i Other: One vent may be used for _up_to-400-sq-.-ft.-of interior space (minimum 2). 'Dual Function Flood and Ventilation Vent Installation Instructions FL5822 R8 II 1540-511 SS 2017-02-28.odf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R8 AE PER5022 SS 2018-06-20.Rdf FL5822 R8 AE SmartVent - Imustaeguirements SS 2017- eated by Independent Third Party: Yes 2.3 SmartVent Model #1540-520 Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). 5822.4 SmartVent Model #15 -521 LI of Use �- Approv •far use In HV- HZ��es "' Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 400 sq. ft. of interior space (minimum 2). Insulated Flood Vent Installation Instructions FL5822 R8 II 1540-520 SS 2017-08-23,p Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports ti5822 R8 AE PER5022 SS 2018-06-70.pdf FL5822 R8 AE SmartVent - Impact Requirements S5 2017- 08 23.odf Created pendent Third Party: Insulated Flood Vent Installation Instructions FL5822 R8 II 1540-521 SS 2017-02-28 Of Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R8 AE PER5022 SS 2018-06-20.p�if FL5822 R8 AE SmartVent - Impact Requirements SS 2017- 08-23.2df Created by Independent Third Party: Yes 5822.5 SmartVent Model #1540-524 116" Garage Door Flood Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). See installation Instructions for allowable pressures per door construction. Installation Instructions FL5822 R8 II 1540-524 SS 2018-08-17,Wif 1 Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 i Created by Independent Third Party: Yes i Evaluation Reports FL5822 R8 AE PER5892 SS 2018-08-17,pdf FL5822 R8 AE SmartVent -Im act Renyiremgnt5 SS 2017 - OB -2 O" Created by Independent Third Party: Yes T www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvMdF6zR4iHLm1 meckcmccEdXH7GOGk3yg%3d 213 6/1/2021 5822.6 Florida Building Code Online SmartVent Model #1540-570 Wood Wall Insulated Flood Vent Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure:+100/-100 Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). Installation Instructions FL5822 R8 II 1540-570 SS 2017-02-28.01f Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R8 AE PER5022 SS 2018-06-20.f FL5822 R8 AE SmartVent - Imguirements SS 2017- 08-23.0f Created by Independent Third Party: Yes 5822.7 SmartVent Model #1540-574 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). See Installation Instructions for allowable pressures per door construction. 14.5" Garage Door Flood Vent Installation Instructions FL5822 R8 II 1540-574 SS 2018-08-17.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R8 AE PER5892 SS 2018-08-17.pff FL5822 RB AE SmartVent - Impact Requirements SS 2017- , 08-23.0f Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click time_. Product Approval Accepts: Credit Card Safe si curitC>i 1 1 RICs RECEIVED BY: C.R. JUN 0 1 2021 PLANNING & DEVELOPMENT CITY OF CLEARWATER www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvMdF6zR4IHLm 1 meckcmccEdXH7GOGk3yg%3d 3/3 380 WINDWARD PASS BCP2020-040680B NEW SF HOME DVORAK, STEPHEN Zoning: Island Estates 0 Atlas #: 267B 8 1/4" R/O HURRIBOND GRIP & SEAL ADHESIVE LOCATION (FLANGE) VENT DOOR VENT FRAME FIGURE 2 SIDE VIEW CUPS INSTALLED: TWO ON TOP TWO ON BOTTOM DETAIL DIAGRAM MODEL 1540-520 FLOOD VENT INSULATED 16 1/4" R/O FLOAT SLOTS FIGURE 1 FRONT VIEW Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document ‘‘N S F. Date: 2017.08.23 19:01:08 -04'00' s CLIP SLOTS USE TWO TOP= * AND TWO BOTTOM w //� Tity .E;;:.44. of AOINORI .• N `,9578 /ONAL 0•` 4 d FIGURE 3 SIDE VIEW 12" MAX FROM FINAL GRADE ) )(:)/ /( ).( /.( SMART VENT® 877-441-8368 WWW.SMARTVENT.COM SMART VENT FOUNDATION FLOOD VENTS 430 ANDBRO DR. UNIT 1 PITMAN NJ 08071 FLOOD VENT INSULATED MODEL 1540-520 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SMART VENT INC. ANY REPRODUCTION OR USE OF THIS INFORMATION WITHOUT THE WRITTEN PERMISSION OF SMARTVENT INC IS PROHIBITED. SIZE A DWG NO. 1540-520 REV B DATE. 8-21-16 SHEET 1 OF 2 Smart VE\T 877— 441— 8368 www.smartvent.com JNSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS & DETAILS MODEL 1540-520 FLOODVENT INSULATED Nat •a -u 1. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE OUT) 2. PREPARE A CLEAN 16.25" WIDE BY 8.25" HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE THAN 12" ABOVE THE FINISHED GRADE. 3. APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME. (FIG. 2) 4. INSERT INSTALLATION CUPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME. 5. THE SPRING ARM OF THE CUPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME. COMPRESS THE BOTTOM TWO CLIPS AND BEGIN SLIPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CUPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS. 6. WITH THE FRAME NOW IN THE OPENING, AND THE BOTTOM SPRINGS IN PLACE, COMPRESS THE TOP SPRINGS AND PUSH THE VENT FRAME INTO THE OPENING COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL. 7. RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK. 8. INSTALL THE DOOR INTO FRAME BY GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND ROTATE UNTIL IT IS LATCHED. 9. TO OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING. DETAIL SPECIFICATIONS: MATERIAL STAINLESS STEEL OPERATION: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION INSTALLATION: SECURED W/ 4 STAINLESS STEEL INSTALLATION CLIPS INCLUDED AND AN ADHESIVE HYDROSTATIC RELIEF: 200 SQ. FT PER VENT REQUIREMENTS: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS COLORS: STAINLESS (STANDARD) EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE) MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY: FEMA, NFIP, ICC, & ASCE SUPPORTIVE DOCUMENTS, TB 1-08, 44CFR 60.3(C)(5), ASCE 24-14 ICC EVALUATION # ESR -2074 SHEET 2 OF 2