967 ELDORADO AVE (2)U.S. DEPARTMENT OF HOMELAND SECURITY
Federal Emergency Management Agency
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
OMB No. 1660-0008
Expiration Date: November 30, 2022
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
SECTION A - PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
MICHAEL F. CLARK AND KELLY M. CLARK
Policy Number:
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Box No.
967 El Dorado Avenue
Company NAIC Number:
City State ZIP Code
Clearwater Beach Florida 33767
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 7, Block 60 - Mandalay - Plat Book 14, Page 32 - Parcel #05-29-15-54666-060-0070
A4. Building Use (e.g.,
A5. Latitude/Longitude:
A6. Attach at least
A7. Building Diagram
A8. For a building
a) Square footage
b) Number of permanent
c) Total net area
d) Engineered
A9. For a building with
a) Square footage
b) Number of permanent
c) Total net area
d) Engineered
Residential, Non -Residential, Addition, Accessory, etc.)
Lat. 27.00064°N Long. -82.82691°W
Residential
Horizontal
Datum:
insurance.
above
❑ NAD 1927
adjacent grade
grade 0
x NAD 1983
2
2 photographs
Number '
with a crawlspace
of crawlspace
flood
of flood openings
flood openings?
an attached
of attached
flood
of flood openings
flood openings?
of the building if the
6
Certificate is being used to obtain flood
381.00 sq ft
or enclosure(s):
or enclosure(s)
openings in the crawlspace
in A8.b
or enclosure(s)
400.00 sq in
within 1.0 foot
foot atrove adjacent
in
0.00 sq ft
❑ Yes X No
garage:
garage
openings in the attached garage within 1.o
in A9.b 0.00 sq
❑ Yes x No
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
Bl. NFIP Community Name & Community Number
Clearwater -125096
B2. County Name
Pinellas
B3. State
Florida
B4. Map/Panel
Number
12103C0064
B5. Suffix
G
B6. FIRM Index
Date
08-18-2009
B7. FIRM Panel
Effective/
Revised Date
09-03-2003
B8. Flood
Zone(s)
AE AND VE
• B9. Base Flood E evation(s)
(Zone AO, use Base Flood Depth)
12.0' and 13.0'
B10. Indicate the source
❑ FIS Profile
B11. Indicate elevation
B12. Is the building
Designation
of the
Base Flood Elevation
❑ Community Determined
for BFE in Item B9:
Coastal Barrier Resources
❑
(BFE) data
❑ NGVD
System
CBRS
or base flood
❑ Other/Source:
depth entered in Item B9:
x FIRM
datum used
located in a
Date:
❑ Other/Source:
Protected
1929 x NAVO 1988
(CARS). meow Otherwise
0 CPA
Area (OPA)?
❑ Yes x No
FEMA Form 086-0-33 (12/19)
Replaces MI previous editions.
Form Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
967 El Dorado Avenue
Policy Number.
City State ZIP Code
Clearwater Beach Florida 33767
Company NAIC Number
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations' are based on: ❑ Construction Drawings*
*A new Elevation Certificate will be required when construction of the
C2. Elevations - Zones A1 -A30, AE, AH, A (with BFE), VE, V1 -V30, V
Complete Items C2.a=h below according to the building diagram specified
Benchmark Utilized: City of Clearwater J-02 Vertical
■
building
(with
Datum:
Building Under Construction* x Finished Construction
is complete.
BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO.
in Item A7. In Puerto Rico only, enter meters.
NAVD 1988
Indicate elevation datum
❑ NGVD 1929
used
x
for the elevations in items a) through h) below.
NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 5.9 p feet ❑ meters
b) Top of the next higher floor 17.5 p feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) 15.0 x feet ❑ meters
d) Attached garage (top of slab) N/A x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building 16.1 x feet ❑ meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG) 5.0 x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 5.6 x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including p feet meters
structural support 5.8❑
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect
1 certify that the information on this Certificate represents my best efforts to interpret
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section
Were latitude and longitude in Section A provided by a licensed larrd surveyor?
x
authorized by law
the data available.
1001.
Yes ❑ No
to
I understand
x
certify elevation information.
that any false
Check here if attachments.
Certifier's Name License Number
John O. Brendla 4601
v
"
/��
' `V
P
' Seal
Here
'
ace
U/�0 )
1
30'2-C)�7
Title
Surveyor
Company Name
John C. Brendla & Associates, Inc.
Address
4015 82nd Avenue North
City State ZIP Code
Pinellas Park Florida 33781
Signatur 'Date Telephone Ext.
0 a 03-30-2021 (727) 576-7546 None
Copy al .ag -s of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
Corn ents (cluding type of equipment and location, per C2(e), if applicable)
C2) a. ' - N. g and Storage, C2) . The Lowest Living Floor, C2) e. The A/C landing located on the North side of the House.
NOTE: The Photos are the attachments - 3/30/2021 Revised C2) c.
Benchmark: City of Clearwater Map #J-02 Elev. 4.4385' NAVD - MSL = 0.00
FEMA Form 086-0-33 (12/19)
Replaces all previous editions.
Form Page 2 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
967 El Dorado Avenue
Policy Number.
City State ZIP Code
Clearwater Beach Florida 33767
Company NAIC Number
SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a
complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement
enter meters.
El. Provide elevation information for the following and check the appropriate boxes to show whether
the highest adjacent grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet ❑ meters
LOMA or LOMR-F request,
used. In Puerto Rico only,
the elevation is above or below
❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet ❑ meters
❑ above or • below the LAG.
9 (see pages 1-2 of Instructions),
❑ above or ❑ below the HAG.
❑ above or ❑ below the HAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or
the next higher floor (elevation C2.b in
the diagrams) of the building is ❑ feet ❑ meters
E3. Attached garage (top of slab) is ❑ feet ❑ meters
E4. Top of platform of machinery and/or equipment
servicing the building is ❑ feet ❑ meters
■ above or ❑ below the HAG.
with the community's
certify this information in Section G.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must
SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or
community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
❑ Check here if attachments.
FEMA Form 086-0-33 (12/19)
Replaces all previous editions.
Form Page 3 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
967 El Dorado Avenue
Policy Number:
City State ZIP Code
Clearwater Beach Florida 33767
Company NAIC Number
SECTION G — COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement
used in Items G8—G10. In Puerto Rico only, enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation
data in the Comments area below.)
G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE)
or Zone AO.
G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes.
G4. Permit Number
G5. Date Permit Issued
G6. Date Certificate of
Compliance/Occupancy Issued
G7. This permit has been issued for. ❑
G8. Elevation of as -built lowest floor (including
of the building:
G9. BFE or (in Zone AO) depth of flooding at the
G10. Community's design flood elevation:
New Construction ❑ Substantial Improvement
basement)
❑ feet
❑ feet
❑ feet
❑ meters Datum
building site:
❑ meters Datum
❑ meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments (including type of equipment and location, per C2(e), if applicable)
❑ Check here if attachments.
FEMA Form 086-0-33 (12/19)
Replaces all previous editions.
Form Page 4 of 6
ELEVATION CERTIFICATE
BUILDING PHOTOGRAPHS
See Instructions for Item A6.
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
967 El Dorado Avenue
Policy Number:
City State ZIP Code
Clearwater Beach Florida 33767
Company NAIC Number
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
R
Photo One 4 FRONT
f
Photo One
Photo One Caption Clear Photo One
Photo Two BACK
Photo Two
Photo Two Caption Clear Photo Two
FEMA Form 086-0-33 (12/19)
Replaces all previous editions.
Form Page 5 of 6
ELEVATION CERTIFICATE
BUILDING PHOTOGRAPHS
Continuation Page
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
967 El Dorado Avenue
Policy Number:
City State ZIP Code
Clearwater Beach Florida 33767
Company NAIC Number
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable,
photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8.
v t
I
Photo Three VENT
Photo Three
Photo Three Caption Clear PhetoThree
Photo Four
Photo Four
Photo Four Caption Clear. Photo Four
FEMA Form 086-0-33 (12/19)
Replaces all previous editions.
Form Page 6 of 6
ELEVATION CERTIFICATE
BUILDING PHOTOGRAPHS
OMB No. 1660-0008
Continuation Page Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
967 El Dorado Avenue
Policy Number:
City
Clearwater Beach
State
Florida
ZIP Code
33767
Company NAIC Number
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with,: date taken; "Front View" and "Rear View'; and, if required, "Right Side View" and "Left Side View." When applicable,
photographs must show the found-ition wit!, representative examples of the flood openings or vents, as indicated in Section A8.
I Photo Four Caption
FEMA Form 086-0-33 (12/19)
Replaces all previous editions.
Clear Photo Three
Clear Photo Four
Form Page 6 of 6
Name Michael & Kelly Clark
V ZONE DESIGN CERTIFICATE
Policy Number (Insurance Co. Use)
Building Address of Other Description 967 El Dorado Ave.
Permit No. BCP2019-100983 City Clearwater
State FL Zip Code 33767
SECTION I: Flood Insurance Rate Map (FIRM) Information
Community No. 125096 Panel No. 64 Suffix FIRM Date 09.011 FIRM Zone(s) AE
SECTION II: Elevation Information Used for Design
(NOTE: This section documents the elevations/depths used or specified in the design — it does not document surveyed elevations
and is not equivalent to the as -built elevations required to be submitted during or after construction.]
1. FIRM Base Flood Elevation (BFE) 13.0 feet*
2. Community's Design Flood Elevation (DFE) 15.0 feet*
3. Elevation of the Bottom of Lowest Horizontal Structure Member 15.0 feet*
4. Elevation of Lowest Adjacent Grade 5.2 feet*
5. Depth of Anticipated Scour/Erosion used for Foundation Design 5.0 feet
6. Embedment Depth of Pilings of Foundation Below Lowest Adjacent Grade 25.0 feet
* Indicate elevation datum used in 1-4: 0 NGVD29 El NAVD88 ❑ Other
SECTION III: V Zone Design Certification Statement
I certify that: (1) I have developed or reviewed the structural design, plans, and specifications for construction of the above -
referenced building and (2) that the design and methods of construction specified to be used are in accordance with accepted
standards of practice** for meeting the following provisions:
• The bottom of the lowest horizontal structural member of the lowest floor (excluding piles and columns) is elevated to or above
the BFE.
• The pile and column foundation and structure attached thereto is anchored to resist flotation, collapse, and lateral movement due
to the effects of the wind and water loads acting simultaneously on all building components. Water loading values used are those
associated with the base flood***. Wind loading values used are those required by the applicable State or local building code. The
potential for scour and erosion at the foundation has been anticipated for conditions associated with the base flood, including
wave action.
SECTION IV: Breakaway Wall Design Certification Statement
(NOTE. This section must be certified by a registered engineer or architect when breakaway walls are designed to have a
resistance of more than 20 psf (0.96 kN/m2) determined using allowable stress design]
I certify that: (1) I have developed or reviewed the structural design, plans, and specifications for construction of breakaway walls to
be constructed under the above -referenced building and (2) that the design and methods of construction specified to be used are in
accordance with accepted standards of practice** for meeting the following provisions:
• Breakaway wall collapse shall result from a water load less than that which would occur during the base flood***.
• The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other
structural damage due to the effects of wind and water loads acting simultaneously on all building components (see Section III).
SECTION V: Certification and Seal
This certification is to be signed and sealed by a registered professional engineer or architect authorized by law to certify
structural designs. I certify the V Zone Design Certification Statement (Section III) and
Certification Statement (Section IV, check if applicable).
Certifiers Name Rodney L Collman AIA License Number AR 0008372
Title President
Address 793
City Dun
the Breakaway Wall Design
Company Name SDG Architecture Inc.
Signature
State FL Zip Code 34698
04.22.2022 Telephone 727.736.5463
4/23/2021
FLOP{OA OtiPARIVEYT OK.
Business & Professional Regulation
Florida Building Code Online
BCIS Home I Log In 1 User Registration ( Hot Topics Submit Surcharge 1 Stats & Facts 1 Publications Contact Us j BCIS Site Map Links Search
M OFFICE OF TUE
SECRETARY.
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL5822-R8
Application Type Affirmation
Code Version 2020
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and
ratified by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Smart Vent Products, Inc.
Address/Phone/Email 430 Andbro Dr Unit 1
Pitman, NJ 08071
(877) 441-8368
info@smartvent.com
Authorized Signature Michael Graham
info@smartvent.com
Technical Representative Michael Graham
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
430 Andbro Dr Unit 1
Pitman, NJ 08071
(877) 441-8368
info@smartvent.com
Structural Components
Products Introduced as a Result of New Technology
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Hermes F. Norero P.E.
Evaluation Report
Florida License PE -73778
Quality Assurance Entity Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL5822 R8 COI Smart Vent COI SS 2017-08-18 .pdf
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1612.5(1)(1.2)
1708.2
https://floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgvMdF6zR4iHLmlmeckcmccEdXH7GOGk3yg%3d 1/3
4/23/2021 Florida Building Code Online
1'41 affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity .Yes
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
o N/A
FL5822 R8 COC SA5822 SS 2020-12-07.pdf
Method 2 Option B
12/16/2020
12/16/2020
12/28/2020
FL #
Model, Number or Name
Description
5822.1
SmartVent Model #1540-510
Dual Function Flood and Ventilation Vent
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +100/-100
Other: One vent may be used for up to 200 sq. ft. of interior
space (minimum 2).
Installation Instructions
FL5822 R8 II 1540-510 SS 2017-08-23.0f
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL5822 R8 AE PER5022 SS 2018-06-20.pdf
FL5822 R8 AE SmartVent - Impact Requirements SS 2017-
08-23.pdf
Created by Independent Third Party: Yes
5822.2
SmartVent Model #1540-511
Dual Function Flood and Ventilation Vent
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +100/-100
Other: One vent may be used for up to 400 sq. ft. of interior
space (minimum 2).
Installation Instructions
FL5822 R8 II 1540-511 SS 2017-02-28.pdf
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL5822 R8 AE PER5022 55 2018-06-20.pdf
FL5822 R8 AE SmartVent - Im ac�guirements SS 2017-
08-23.pdf
Created by Independent Third Party: Yes
5822.3
SmartVent Model #1540-520
Insulated Flood Vent
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +100/-100
Other: One vent may be used for up to 200 sq. ft. of interior
space (minimum 2).
Installation Instructions
FL5822 R8 II 1540-520 SS 2017-08-23.pdf
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL5822 R8 AE PER5022 SS 2018-06-20.pdf
FL5822 R8 AE SmartVent - Impact Requirements SS 2017-
08-23.pdf
Created by Independent Third Party: Yes
5822.4 SmartVent Model #1540-521
Insulated Flood Vent
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +100/-100
Other: One vent may be used for up to 400 sq. ft. of interior
space (minimum 2).
Installation Instructions
FL5822 R8 II 1540-521 SS 2017-02-28.pdf
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL5822 R8 AE PER5022 SS 2018-06-20.pdf
FL5822 R8 AE SmartVent - Impact Requirements SS 2017-
08-23.pdf
Created by Independent Third Party: Yes
5822.5
SmartVent Model #1540-524
16" Garage Door Flood Vent
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: One vent may be used for up to 200 sq. ft. of interior
space (minimum 2). See Installation Instructions for allowable
pressures per door construction.
Installation Instructions
FL5822 R8 II 1540-524 SS 2018-08-17.01
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL5822 R8 AE PER5892 SS 2018-08-17.pdf
FL5822 R8 AE SmartVent - Impact Requirements SS 2017-
08-23.pdf
Created by Independent Third Party: Yes
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvMdF6zR4iHLm1 meckcmccEdXH7GOGk3yg%3d
2/3
CERTIFIED TO:
MICHAEL F. CLARK
KELLY M. CLARK
LOPEZ BUILDING COMPANY
CURVE 1
RADIUS=2647.04'(P&M)
ARC=55.62'(P),55.77'(M)
CHORD=55.62'(P), 55.77'(M)
CHORD BEARING=N 11°33'43"E(M)
(NA VD)
SSITE TBM ELEV=4.84'
SET NAIL & DISK (LB 760)
IN ASPHALT PAVEMENT
30•
CONCRETE
DRIVE .
SECTION 32, TOWNSHIP 28 SOUTH, RANGE 15 EAST
LEGAL DESCRIPTION
LOT 7, BLOCK 60, ACCORDING TO THE PLAT OF
MANDALAY
AS RECORDED IN PLAT BOOK 14, PAGES 32-35
OF THE PUBLIC RECORDS OF PINELLAS COUNTY, FLORIDA.
BOUNDARY SURVEY WITH SPOT ELEVATIONS — 12/30/19
STAKED PROPOSED PILINGS AND BUILDING ENVELOPE — 1/08/20
RESTAKE BUILDING ENVELOPE WITH OFFSETS — 1/27/20
TIE—IN/FOUNDATION SURVEY — 3/12/20
ELEVATION CERTIFICATE — 5/15/20
FINAL SURVEY — 3/11/21
FLOOD
4.85 SCA LOONE LIN
ODOO MAPEMA
F-0ONALE) iR
LOt
5.66 8
•C.
WOOD
Ac
FENCE / LANDING
51 0.09,1N0 •
578!!!5•
GUARD RA KETAL
A °NLNENG R
no.00•(P,
09, 95,(141)
s' VINYL FENCE
6 Et 4 0.52 S & O0.76EW
5.75
L
°t 9
Fp(JND 1 2 /
(HALE R
w000 FEN E RotesWER
32,E ND
F-
E
4.98
f7q
d- to
6' vilvy
FENCEL
FENCE
END
r0 .19'E.
LOt10
"'OOP Fp RY
BUILD/NGME
ROOF T EA T E0Q 5 .
OUND 3 5.51
(No /b)8 /R X 5.35
(NA VD)
SITE TBM ELEV=4.78'
SET BOX CUT IN WALK
ABBREVIATIONS:
A/C = AIR CONDITIONER
q= CENTERLINE
CM = CONCRETE MONUMENT
CO = CLEANOUT
C PALM = CABBAGE PALM TREE
ELEV = ELEVATION
ID = IDENTIFICATION
IR = IRON ROD
LB = LICENSED BUSINESS
(M) = MEASURED
(P) = PLAT
(P&M) = PLAT AND MEASURED
(s) = SET
TBM = TEMPORARY BENCHMARK
WM = WATER METER
FOUNDWITH COM "
MON NAIL
I ——NORTHRIGHT. OFWAY LINE
LAUREL STREET
5.42 5.4
79044,33"4,
W \-5.33
o/t 5.35
N;H
o /0
0
1
X 07/'(' P(5)) F
ENCI
Fp
co� NN�5.5(NO ig�
FENCE LIjy-5.5
0.28 A E
LOt 6
60
NOTE:
5.95
LOt 11
•Ne'—XX.X = EXISTING ELEVATION
Job Number: 1912-68
Drawn: DS
N
S
NORTH BASIS:
ASSUMED
SCALE: t' = 20'
Flood Zone Data:
FLOOD ZONE(S): AE(12') AND VE(13')
COMMUNITY PANEL #125096 12103C0064G
REVISED 9/3/03
Assumed Basis of Bearings:
NORTHERLY BOUNDARY LINE OF LOT 7, BLOCK 60
AS BEING S.78'31'15"E., ASSUMED.
(NO PLAT BEARINGS)
Reference Benchmark:
CITY OF CLEARWATER J-02
NAVD ELEV=4.4385, MSL=0.00
This survey was prepared without the benefit of a title search and is
subject to all easements, rights—of—way, and other matters of record.
Survey not valid without the signature and the original raised seal of a
Florida Licensed Surveyor and Mapper.
This survey is made for the exclusive use of the current owners of the
property and also those who purchase, mortgage or guarantee the title
thereto within one (1) year from latest date shown hereon.
1912-68.CRD
FIELD BOOK 960_ PAGE(S) 73-74
Prepared by:
JOHN C. BRENDLA AND ASSOCIATES, INC.
PROFESSIONAL LAND SURVEYORS AND MAPPERS
4015 82nd Avenue North
Pinellas Park, Florida 33781
phone (727) 576-7546 — fax (727) 577-9932
I hereby .certify that the survey represented hereon meets the
requirements of Chapter 5 —17, Florida Administrative Code.
JOHN 0. BRENDLA
oridaSurveyor's Registration No. 4601
Certificate of Authorization No. 760