667 HARBOR IS\scpm't* `3cPa?c
U.S. DEPARTMENT OF HOMELAND SECURITY
Federal Emergency Management Agency
National Flood Insurance Program
ELEVATION CERTIFICA'
Important: Follow the instructions on pages 1-i
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) in:
SECTION A - PROPERTY INFORMATION
Al. Building Owner's Name
William G. Wright and Heidi S. Wright
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route ar
Box No.
667 Harbor Island
Ci
State
RECEIVED BY: J.A.W.
APR 0 7 2020
PLANNING & DEVELOPMENT
CITY OF CLEARWATER
667 HARBOR ISL
BCP2019-0306258
COMP EC
WILLIAM G WRIGHT
Zoning: Island Estates
Clearwater Florida 34683
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 16, Unit 7-C, Units 6D, 7A, 7C Island Estates of Clearwater. Plat Book 64, Pages 1 and 2 Public records of Pinellas County
A4. Building Use (e.g.,
A5. Latitude/Longitude:
A6. Attach at least
A7. Building Diagram
A8. For a building
a) Square footage
b) Number of permanent
c) Total net area
d) Engineered
A9. For a building with
a) Square footage
b) Number of permanent
c) Total net area
d) Engineered
Residential, Non -Residential, Addition, Accessory, etc.)
Lat. 27°59'21.13"N Long. 82°48'58.51"W
Residential
Horizontal
Datum: ❑ NAD 1927
insurance.
above adjacent grade
grade 4
x NAD 1983
1
2 photographs
Number
with a crawlspace
of crawlspace
flood
of flood openings
flood openings?
an attached
of attached
flood
of flood openings
flood openings?
of the building if the
1B
Certificate is being used to obtain flood
45.00 sq ft
or enclosure(s):
or enclosure(s)
openings in the crawlspace
in A8.b
or enclosure(s)
200.00 sq in
within 1.0 foot
foot above adjacent
in
793.00 sq ft
x Yes ❑ No
garage:
garage
openings in the attached garage within 1.0
in A9.b 800.00 sq
x Yes ❑ No
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
City of Clearwater 125096
B2. County Name
Pinellas
B3. State
Florida
B4. Map/Panel
Number
12103C0102
B5. Suffix
G
B6. FIRM Index
Date
08-18-2009
B7. FIRM Panel
Effective/
Revised Date
09-03-2003
B8. Flood
Zone(s)
AE
B9. Base Flood E evation(s)
(Zone AO, use Base Flood Depth)
11.0'
B10. Indicate the source
❑ FIS Profile
B11. Indicate elevation
B12. Is the building
Designation
of the
Base Flood Elevation
❑ Community Determined
for BFE in Item B9:
Coastal Barrier Resources
❑
(BFE) data or base flood
❑ Other/Source:
❑ NGVD 1929
System (CBRS)
CBRS ❑ OPA
depth entered in Item B9:
x FIRM
datum used
located in a
Date: N/A
❑ Other/Source:
x NAVD 1988
area or Otherwise
Protected Area (OPA)?
❑ Yes x No
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction*
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones A1—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, ARAE,
Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico
Benchmark Utilized: City of Clearwater 1-04 Vertical Datum: NAVD 88 ELEVATION
x Finished Construction
AR/A1—A30, AR/AH, AR/AO.
only, enter meters.
= 5.2452
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 x NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 13.10
Check the measurement used.
x feet ❑ meters
b) Top of the next higher floor
N/A x feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only)
N/A x feet ❑ meters
d) Attached garage (top of slab) 7.53
x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building 13.43
(Describe type of equipment and location in Comments)
x feet ❑ meters
f) Lowest adjacent (finished) grade next to building (LAG) 6.00
x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 6.70
x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including
structural support 7.50
x feet ❑ meters
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by
I certify that the information on this Certificate represents my best efforts to interpret the data available.
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
law to certify elevation information.
I understand that any false
❑ Check here if attachments.
Were latitude and longitude in Section A provided by a licensed land surveyor? x Yes ❑ No
Certifier's Name License Number
JEFF M. HARTLEY #7123
)���
: 5 ' .?.?
x?��
t�3x.
u
?fes gN.
�
try ,x ,
4� y
,, n� ��� `R
n rrCaa f�4y`3�
;,n�a a r ".""
Title
PLS
Company Name
INITIAL POINT LAND SURVEYING, LLC.
Address
1708 WATER OAK DRIVE
City State ZIP Code
TARPON SPRINGS Florida 34689
Sig r 1 u • Date Telephone Ext.
�,/ 3/2y1 (727) 831-1990
/ , • ,ages of this El tion Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
Com ents (including type of equipment and location, per C2(e), if applicable)
Data in C2.f-h is only accurate to 0.1'; ignore the second decimal place, as this is automatically added by the FEMA form.
C2(e) = A/C on cantilever platform on right side of building
Flood vents "Smart vents" Model 1540-510 200 S.F per vent (4) vents in garage
Storage area at back left of building with smart vent model 1540-510 (1) vent
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 2 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a
complete Sections A, Band C. For Items E1—E4, use natural grade, if available. Check the measurement
enter meters.
El. Provide elevation information for the following and check the appropriate boxes to show whether
the highest adjacent grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet ❑ meters
LOMA or LOMR-F request,
used. In Puerto Rico only,
the elevation is above or below
❑ above or ❑ below the HAG.
❑ above or ❑ below the LAG.
9 (see pages 1-2 of Instructions),
❑ above or ❑ below the HAG.
❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet ❑ meters
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or
the next higher floor (elevation C2.b in
the diagrams) of the building is ❑ feet ❑ meters
E3. Attached garage (top of slab) is ❑ feet ❑ meters
E4. Top of platform of machinery and/or equipment
servicing the building is ❑ feet ❑ meters
❑ above or • below the HAG.
with the community's
certify this information in Section G.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must
SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or
community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
lG .7 ft ,/,/, , ' / seitA,r' lie �7 337
Address / // City State ZIP Code
_ 'WV.7Z 717 %��?�
Sig = ure Date Telephone
Comments
❑ Check here if attachments.
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 3 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
SECTION G — COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement
used in Items G8—G10. In Puerto Rico only, enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation
data in the Comments area below.)
G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE)
or Zone AO.
G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes.
G4. Permit Number
G5. Date Permit Issued
G6. Date Certificate of
Compliance/Occupancy Issued
G7. This permit has been issued for: ❑
G8. Elevation of as -built lowest floor (including
of the building:
G9. BFE or (in Zone AO) depth of flooding at the
G10. Community's design flood elevation:
New Construction ❑ Substantial Improvement
basement)
❑ feet
❑ feet
❑ feet
❑ meters Datum
building site:
❑ meters Datum
❑ meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments (including type of equipment and location, per C2(e), if applicable)
❑ Check here if attachments.
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 4 of 6
ELEVATION CERTIFICATE
BUILDING PHOTOGRAPHS
See Instructions for Item A6.
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
lv' j - 1 k..
IN 1111 l•�
1■
_._ .T':w _.�p7E�r�''s .. s I S
_ _ moi,
_ s y
.. -.
`
Photo One
Photo One Caption FRONT VIEW Clear Photo One
_ \ 1
/i
Of 1
."' / t'i m.e
1
Photo Two
Photo Two Caption REAR VIEW Clear Photo Two
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 5 of 6
ELEVATION CERTIFICATE
BUILDING PHOTOGRAPHS
Continuation Page
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable,
photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8.
)4 t;\
air
i '{
-
•
tl
, -*
na
Photo Three
Photo Three Caption LEFT
SIDE VIEW Clear Photo Three
1
'tlr)tp
1
Photo Four
Photo Four Caption RIGHT SIDE VIEW Clear Photo Four
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 6 of 6
U.S. DEPARTMENT OF HOMELAND SECURITY
Federal Emergency Management Agency
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
OMB No. 1660-0008
Expiration Date: November 30, 2018
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owners Name
William G. Wright and Heidi S. Wright
Policy Number:
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Box No.
667 Harbor Island
Company NAIC Number:
City State ZIP Code
Clearwater Florida 34683
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 16, Unit 7-C, Units 6D, 7A, 7C Island Estates of Clearwater. Plat Book 64, Pages 1 and 2 Public records of Pinellas County
A4. Building Use (e.g.,
A5. Latitude/Longitude:
A6. Attach at least
A7. Building Diagram
A8. For a building
a) Square footage
b) Number of permanent
c) Total net area
d) Engineered
A9. For a building with
a) Square footage
b) Number of permanent
c) Total net area
d) Engineered
Residential, Non -Residential, Addition, Accessory, etc.)
Lat. 27°59'21.13"N Long. 82°48'58.51'W
Residential
Horizontal
Datum:
insurance.
above
❑ NAD 1927
adjacent grade
grade 4
x NAD 1983
N/A
2 photographs
Number
with a crawlspace
of crawlspace
flood
of flood openings
flood openings?
an attached
of attached
flood
of flood openings
flood openings?
of the building if the
1B
Certificate is being used to obtain flood
N/A sq ft
or enclosure(s):
or enclosure(s)
openings in the crawlspace
in A8.b
or enclosure(s)
N/A sq in
within 1.0 foot
foot above adjacent
in
636.00 sq ft
❑ Yes x No
garage:
garage
openings in the attached garage within 1.0
in A9.b 480.00 sq
❑ Yes x No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
City of Clearwater 125096
B2. County Name
Pinellas
B3. State
Florida
B4. Map/Panel
Number
12103C0102
B5. Suffix
G
B6. FIRM Index
Date
08-18-2009
B7. FIRM Panel
Effective/
Revised Date
09-03-2003
B8. Flood
Zone(s)
AE
B9. Base Flood E evation(s)
(Zone AO, use Base Flood Depth)
11.0'
B10. Indicate the source
❑ FIS Profile
B11. Indicate elevation
B12. Is the building
Designation
of the
Base Flood Elevation
❑ Community Determined
for BFE in Item B9:
Coastal Barrier Resources
❑
(BFE) data or base flood
❑ Other/Source:
❑ NGVD 1929
System (CBRS)
CBRS ❑ OPA
depth entered in Item B9:
x FIRM
datum used
located in a
Date: N/A
❑x NAVD 1988 ❑ Other/Source:
area or Otherwise Protected
Area (OPA)?
❑ Yes x No
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
❑ Finished Construction
AR/A1—A30, AR/AH, AR/AO.
Rico only, enter meters.
= 5.2452
Cl. Building elevations are based on: ❑ Construction Drawings* x Building Under Construction*
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones Al A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE,
Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto
Benchmark Utilized: City of Clearwater 1-04 Vertical Datum: NAVD 88 ELEVATION
Indicate elevation datum used for the elevations in items a) through h) below.
■ NGVD 1929 x NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 13.10
the measurement used.
x feet ❑ meters
b) Top of the next higher floor N/A
x feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) N/A
x feet ❑ meters
d) Attached garage (top of slab) N/A
x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment and location in Comments) N/A
x feet meters
❑
f) Lowest adjacent (finished) grade next to building (LAG) 6.20
x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 6.60
x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including
structural support 6.50
x feet ❑ meters
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by
I certify that the information on this Certificate represents my best efforts to interpret the data available.
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
law to certify elevation information.
I understand that any false
❑ Check here if attachments.
Were latitude and longitude in Section A provided by a licensed land surveyor? x Yes ❑ No
Certifiers Name License Number
JEFF M. HARTLEY #7123
r .
rr'
^'� %f
t ,
Title
PLS
Company Name
INITIAL POINT LAND SURVEYING, LLC.'
Address
1708 WATER OAK DRIVE
City State ZIP Code
TARPON SPRI GS Florida 34689
Signat :� ate Telephone Ext.
/ It./ I 7/11 It? (727) 831-1990
Co �� sof this icate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
�-"'s
r • (includingtype of equipment and location,per C2(e),if a applicable)
PP )
Data in C2.f-h is only accurate to 0.1'; ignore the second decimal place, as this is automatically added by the FEMA form.
C2(e) = No equipment servicing building currently installed
Flood vents to be "Smart vents" Model 1540-510 or equal ICC -ES certified to ventilate 200 S.F of Floor area per construction plans
Garage floor not poured
Current flood openings 8"x15" (4) in garage
Storage area at back left of building with flood opening 8"x15" (1)
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 2 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a
complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement
enter meters.
El. Provide elevation information for the following and check the appropriate boxes to show whether
the highest adjacent grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement,
LOMA or LOMR-F request,
used. In Puerto Rico only,
the elevation is above or below
❑ above or ❑ below the HAG.
❑ above or ❑ below the LAG.
9 (see pages 1-2 of Instructions),
❑ above or ❑ below the HAG.
❑ above or ❑ below the HAG.
❑ above or ❑ below the HAG.
with the community's
certify this information in Section G.
crawlspace, or enclosure) is • feet ❑ meters
b) Top of bottom floor (including basement,
crawlspace, or enclosure) is • feet ❑ meters
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or
the next higher floor (elevation C2.b in
the diagrams) of the building is ❑ feet ❑ meters
E3. Attached garage (top of slab) is • feet ❑ meters
E4. Top of platform of machinery and/or equipment
servicing the building is ■ feet ❑ meters
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must
SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owners authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or
community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
❑ Check here if attachments.
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 3 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
SECTION G — COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement
used in Items G8—G10. In Puerto Rico only, enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation
data in the Comments area below.)
G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE)
or Zone AO.
G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes.
G4. Permit Number
G5. Date Permit Issued
G6. Date Certificate of
Compliance/Occupancy Issued
G7. This permit has been issued for: ❑
G8. Elevation of as -built lowest floor (including
of the building:
G9. BFE or (in Zone AO) depth of flooding at the
G10. Community's design flood elevation:
New Construction ❑ Substantial Improvement
basement)
❑feet
❑ feet
❑ feet
meters Datum
building site:
❑ meters Datum
❑ meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments (including type of equipment and location, per C2(e), if applicable)
667 HARBOR IBL
BCP2019-030625A
under const
WILLIAM G WRIGHT
Zoning: Island Estates Atlas #: 258B
❑ Check here if attachments.
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 4 of 6
ELEVATION CERTIFICATE
BUILDING PHOTOGRAPHS
See Instructions for Item A6.
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
r • r,t.
*" 1 fir�/ t♦/
i , ,e..-
y T' .
f . t `_
litir lima.-
i
_ .Wi
i,
Jill
'TS
Photo One
Photo One Caption FRONT VIEW Clear Photo One
Photo Two
Photo Two Caption REAR VIEW Clear Photo Two
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 5 of 6
ELEVATION CERTIFICATE
BUILDING PHOTOGRAPHS
Continuation Page
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
667 Harbor Island
Policy Number:
City State ZIP Code
Clearwater Florida 34683
Company NAIC Number
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable,
photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8.
.wa
4 q
t .l; yJ'•
-co .. -
Photo Three
Photo Three Caption LEFT SIDE VIEW Clear Photo Three
x
II I
4111*
1nn�c
Photo Four
Photo Four Caption RIGHT SIDE VIEW Clear Photo Four
FEMA Form 086-0-33 (7/15)
Replaces all previous editions.
Form Page 6 of 6