Loading...
CSP2017-12025CITY OF CLEARWATFR CAA ;vRvv arER PLANING & DIA' 1 O Mi yT, POST Or-ncr. &,x 4748, Cu ARU vTFR, FLORIDA 33758 -4748 y9i'u:IYit SlRucts Bi.ILDING, 100 S<,LTH MvRl1.1: A I -.iu., Ci.r-:axvGv ER, FLORU)A 33756 '1'r_EP11O v s (727) 562 -4567 FAx (727) 562 -4865 December 22, 2017 Pierre Cournoyer 1467 Cleveland Street Clearwater, FL 33775 RE: 123 N. Fort Harrison Avenue Development Order — CSP2017 -12025 Dear Mr. Cournoyer: The Planning and Development Department Staff reviewed your Comprehensive Sign Program application for 123 N. Fort Harrison Avenue pursuant to Community Development Code (CDC) Section 3 -1808. The proposed plan includes the following: 1. One Attached internally illuminated light box sign 6.5 square feet in area (0.657 percent of the facade area) mounted directly to the west building facade (no raceways). The upper portion of the sign will read "WISE" in platinum letters, and the lower portion of the sign will read "CLEARWATER" in platinum letters; 2. One Attached non - internally illuminated sign 12.1 square feet in area (0.013 percent of the facade area) mounted directly to the west building facade (no raceways). The sign is circular in shape with the outer banding to read "WORLD INSTITUTE OF SCIENTOLOGY ENTERPRISES" in green -gold letters, and the inner portion of the sign comprising a raised image of a tiger and two tiger cubs that is green -gold in color; and, 3. One Attached non - internally illuminated building identification sign 5.1 square feet in area (0.671 percent of the facade area) mounted directly to the east building facade (no raceways). The sign will read "WISE CLEARWATER" in revere pewter letters on a gunmetal background. The Comprehensive Sign Program has been APPROVED and this letter constitutes a Development Order pursuant to CDC Section 4- 202.E. The approval is based on, and must be consistent with the site plan, elevations, and drawings received on December 15, 2017, and application received December 21, 2017, as described above, and is subject to the following conditions: Conditions of Approval: 1. That any future attached signs shall be flush mounted to the building (no raceways); George N. Cretekos, Mayor Doreen Caudell, Councilmember Dr. Bob Cundiff, Councilmember Bill 'orison, Councilmember Hoyt Hamilton, Councilmember "Equal Employment and Affirmative Action Employer" CSP2017 -12025 Development Order Page 2 2. That any future requests inconsistent with this approved Comprehensive Sign Program shall require an amendment to be filed, reviewed and approved by the Planning and Development Department prior to issuance of a building (sign) permit; 3. That the lighting for the attached signs be controlled by a mechanical timer and be turned off at midnight or whenever the business is closed, whichever is later; and, 4. That all other Code requirements /restrictions of Division 18 (Signs) are met, including but not limited to, grand opening banners, window, temporary, construction and sale leasing signs. Pursuant to CDC Section 4 -303, an application for a building (sign) permit shall be made within one (1) year of the date of this Development Order (December 22, 2018). All signs shall be installed and any conditions met within six (6) months of the date of issuance of the initial building (sign) permit. Permitted time frames do not change with successive owners. The issuance of this Development Order does not relieve you of the necessity to obtain any building permits or pay any fees that may be required. In order to facilitate the issuance of any permit or license affected by this approval, please bring a copy of this letter with you when applying for any permits or licenses that require this prior development approval. Should you have any questions, please contact Robert G. Tefft, Senior Planner, at (727) 562- 4504 or via e -mail at robert.tefft@myclearwater.com. Sincerely, Gina L. Clayton, Assistant Planning and Development Director cc: Daniel Knight, Sign Inspector "Equal Employment and Affirmative Action Employer" 13 .1 ,AND AFAU.'IIFI'L• BA) [0 BI. AC: It CSI't.l • itotf PLANNING AND DEVELOPMENT DEPARTMENT COMPREHENSIVE SIGN PROGRAM APPLICATION It is the responsibility of the applicant to submit complete and correct information. Any misleading, deceptive, incomplete or incorrect information may invalidate your application. The applicant, by filing this application, agrees to comply with all applicable requirements of the Community Development Code. All applications are to be filled out completely and correctly, and submitted either in person or via email (no fax or deliveries) to the Planning and Development Department. APPLICATION FEES: $400 Comprehensive Sign Program $150 Comprehensive Sign Program Amendment PROPERTY OWNER (PER DEED): MAILING ADDRESS: PHONE NUMBER: 727- 445 -4338 EMAIL: legaldirflag @flag.org Church of Scientology Flag Service Organization, Inc. 503 Cleveland St, Clearwater, FL 33755 APPLICANT: MAILING ADDRESS: PHONE NUMBER: EMAIL: AGENT OR REPRESENTATIVE: MAILING ADDRESS: PHONE NUMBER: EMAIL: Pierre Cournoyer 1467 Cleveland St, Clearwater, FL 33755 727 - 410 -3692 pierre.cour @gmail.com Glen Stilo 503 Cleveland St, Clearwater, FL 33755 727 - 445 -4338 legaldirflag @flag.org ADDRESS OF SUBJECT PROPERTY: 123 N. Ft Harrison Ave, Clearwater, FL 33755 PARCEL NUMBER(S): 16- 29 -15- 32274 - 001 -0040 DESCRIPTION OF REQUEST: Specifically identify the request (include all requested code flexibility; e.g., height, size, number of signs, etc.): Addition of a total of (3) attached signs, two being located on the West facade with the remaining sign located on the Eastern portion of the building facing Waterson. All signage integrates with the building design and motif and forms a congruency with the adjacent properties located along Ft Harrison Ave while not exceeding the 3% signage- facade ratio. Page 1 of 6 REVISED: OCTOBER 2017 PROOF OF OWNERSHIP AND SURVEY: 4 Submit a copy of the title insurance policy, deed or affidavit attesting to ownership of the property. a Submit a signed and sealed survey of the property. SIGN PLAN AND ELEVATION PLAN SUBMITTAL REQUIREMENTS: Sign plans with the following information (not to exceed 24" x 36 "): 0 All dimensions; {ii Size of site (in acreage and in square feet); 0 Bar scale and date prepared; a To -scale drawings, in color, of all proposed signage (attached, freestanding and directional signs), which include the following: i. Dimensions with dimensional arrows; ii. Sign area in square feet; iii. Height and width of sign and sign structure, measured in feet; iv. Labels of all colors; v. Surface area of sign proposed; vi. Text copy including the message of the sign; vii. Changeable copy, if proposed; and, viii. Describe any illumination, including the type, placement, intensity, hours of illumination and system to automatically turn off lighting when the business is closed, and sign area to be illuminated. SITE PLAN SUBMITTAL REQUIREMENTS: 4 Site plan with the following information (not to exceed 24" x 36 "): 4 All dimensions; 4 North arrow; id Engineering bar scale (minimum scale: one -inch equals 50 feet), and date prepared; O Location map; 4 Property lines; O Footprint and size of all buildings and structures; 4 All required five -foot setbacks as measured from the property line; 4 All existing and proposed points of access; 4 All required sight triangles; liti Location of all public and private easements and street rights -of -way within and adjacent to the site; 0 Location of all existing and proposed sidewalks; a Lot frontage on all rights -of -way; 4 Location, with labels, of all proposed and existing freestanding signs (indicate whether to be removed); 4 Location, with labels, of all proposed and existing attached signs (indicate whether to be removed); O Identification of water courses, wetlands, tree masses and specimen trees, including description and location of understory, groundcover vegetation and wildlife habitats or other environmentally unique areas, A Sight visibility triangles, depicted and labeled; a Location of all proposed landscape material including size and species; lid Land areas expressed in square feet and acres; and, d Location of the sign in relation to property lines, public rights -of -way, easements, buildings and other signs on the property. Page 2 of 6 REVISED: OCTOBER 2017 WRITTEN SUBMITTAL REQUIREMENTS: Signage which is proposed as part of a Comprehensive Sign Program may deviate from the minimum sign standards in terms of number of signs per business or parcel of land, maximum area of a sign face per parcel of land and the total area of sign faces per business or parcel of land, subject to compliance with the flexibility criteria set out in Section 3- 1808.C. A Comprehensive Sign Program shall be approved pursuant to the provisions set out in Section 4 -1008. Prohibited signs in Section 3 -1804 are not eligible for a Comprehensive Sign Program. Electronic changeable message signs, back -lit awnings, cabinet signs, and raceway signs are not eligible to be utilized as signs as part of a Comprehensive Sign Program. As part of a Comprehensive Sign Program, the community development coordinator shall review all sign types (freestanding, attached, window, directional, etc.) for the business and /or the development parcel to achieve compliance in so far as possible with these current regulations. A master sign plan for shopping centers, including all out parcels, and office complexes shall include all types of signs for all tenants /uses within the development parcel. The community development coordinator may allow for flexibility in reviewing the master sign plan if it results in a substantially improved and comprehensive proposal. With a master sign plan, the community development coordinator may permit directional signs at a size and location(s) related to the development project, with up to a maximum height of six feet. Provide written responses as to how the following Comprehensive Sign Program flexibility criteria are met by this proposal: 1. Architectural theme. a. The signs proposed in a comprehensive sign program shall be designed as a part of the architectural theme of the principal buildings proposed or developed on the parcel proposed for development and shall be constructed of materials and colors which reflect an integrated architectural vocabulary for the parcel proposed for development; or b. The design, character, location and /or materials of all freestanding and attached signs proposed in a comprehensive sign program shall be demonstrably more attractive than signs otherwise permitted on the parcel proposed for development under the minimum signs standards. All signs must be architecturally integrated into /with the design of the building and /or site using similar and coordinated design features, materials and colors, etc. Each building on the blocks south of this property has its own unique identity and the signage combined with the change of exteri, paint colors serves to better identify each building by the universally recognized logos that symbolize each. The signage integrates with the quaint Florida design and complements the picturesque Floridian vernacular embraced by these buildings. 2. The height of all freestanding signs proposed through the comprehensive sign program shall relate to the design of the sign and shall not exceed 14 feet in height, except in the D and T Districts, the height shall not exceed six feet in height except for signs associated with publicly -owned property and /or public projects which are architecturally and aesthetically integrated into a fence and /or wall. None of the signs exceed 14 feet in height. The sizing of each of the signs was carefully chosen based on the sizing of other architectural elements unique to each building facade and to ensure that none were oversized. The finalized sizes are based on available spacing between architectural details and the size of the facade. Page 3 of 6 REVISED: OCTOBER 2017 3. Any lighting that is internal to the sign letters or graphic elements (e.g., internally lit or back -lit, or that is indirect exterior lighting, e.g., goose neck lighting) proposed as a part of a comprehensive sign program is automatically controlled so that the lighting is turned off at midnight or when the business is closed, whichever is later. The main sign above the door at the West side is internally lit, while the round logo on the West side is indirectly lit. The lighting on both signs will be connected to a timer which is automatically controlled and will be turned off at midnight. 4. The height, area, number and location of signs permitted through the comprehensive sign program shall be determined by the community development coordinator based on the following criteria: overall size of site, relationship between the building setback and sign location, frontage, access and visibility to the site, intended traffic circulation pattern, hierarchy of signage, scale and use of the project, consistency with Beach by Design, Clearwater Downtown Redevelopment Plan or any other applicable special area plan and submittal of a master sign plan for the development parcel /project. Additionally, the maximum permitted sign area shall be based on the following formula when evaluated against the above criteria: a. Attached signs. The maximum area permitted for attached signage shall range from one percent up to a maximum of six percent of the building facade to which the sign is to be attached. In no event shall the size of an attached sign exceed 200 square feet. For regional malls, the maximum size of any attached sign that is otherwise allowed shall not exceed six percent of the building facade facing the street, but in no case more than 300 square feet. The attached signage square footage represents an aggregate of less than 3% of the building facade. b. Freestanding signs. The maximum permitted area of all freestanding signs on a site shall not exceed the range of sign area permitted by the street frontage or building facade calculation methods set forth below: i. One square foot per two linear feet of street frontage; or ii. One square foot per 100 square feet of building facade facing street frontage. There are no freestanding signs. 5. The signage proposed in a comprehensive sign program shall not have an adverse impact on the community character of the City of Clearwater. The signage will not have an adverse impact on the community character of the City of Clearwater but rather will enhance the community with aesthetic elements as was done with the similar buildings along Ft Harrison Ave. Page 4 of 6 REVISED: OCTOBER 2017 6. The signage proposed in a comprehensive sign program will not have an adverse impact on the value of property in the immediate vicinity of the parcel proposed for development. The proposed signage will not have an adverse impact on the value of property in its vicinity, as the new signage is harmonious with the building exterior design and its rendition will be homogeneous with the existing signage located on the same block 7. The signage proposed in a comprehensive sign program will result in the elimination of existing unattractive signage and nonconforming signage and will result in an improvement to the appearance of the parcel proposed for development in comparison to signs otherwise permitted under the minimum sign standards. This signage works to ensure that the building is identified as its own unique structure and integrates with the paint colors associated with the org The tonal palettes, clean detailing and classic design of the new exteriors are fully realized with this harmonious signage. Each sign has been architecturally integrated into key elements of the building facade giving an integrated look as if it were part of the original structure. This was done while paying careful attention to keeping the total signage area under the maximum allowable square footage. 8. The signage proposed in a comprehensive sign program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the parcel proposed for development is located. Please see above. COMPREHENSIVE SIGN PROGRAM — PROPOSED SIGN SUMMARY: Height: Address: Sign Type: (freestanding) Length: Width: Area: 123 N Ft Harrison Ave 123 N Ft Harrison Ave 123 N Ft Harrison Ave Wall Wall Wall N/A N/A N/A 4' -0" 3' -7" 4' -3" (circle) 12.57 1' -9" 6.3 1' -2" 5 Page 5 of 6 REVISED: OCTOBER 2017 PLANNING AND DEVELOPMENT DEPARTMENT AFFIDAVIT OF OWNERSHIP 1. Provide names of all property owners on deed — PRINT full names: Church of Scientology Flag Service Organization Inc. 2. That (I am /we are) the owner(s) and record title holder(s) of the following described property: 123 N Ft Harrison Ave. Clearwater FL 33755 3. That this property constitutes the property for which a request for (describe request): For three attached signs, two of which are located on the West side of the property and one on the East 4. That the undersigned (has /have) appointed and (does /do) appoint: Glen Stilo as (his /their) agent(s) to execute any petitions or other documents necessary to affect such petition; 5. That this affidavit has been executed to induce the City of Clearwater, Florida to consider and act on the above described property; 6. That site visits to the property are necessary by City representatives in order to process this application and the owner authorizes City representatives to visit and photograph the property described in this application; 7. That (I /we), the undersigne orl , hereby certify that the foregoing is true and correct. Property Owner Property 0 ner GLEN E. STILPalt CHURCH OF SCIENTOLOGY G SERVICE ORA[NIt. Dtr STATE OF FLORIDA, COUNTY OF PINELLAS BEFORE ME THE UNDERSIGNED, AN OFFICER DULY COMMISSIONED BY THE LAWS OF THE STATE OF FLORIDA, ON THIS I � DAY OF 0 - c_�r , / 2.-81 7 , PERSONALLY APPEARED �s �G 511/0 5� c ` ' r'�j ct ay/el'o `ko- -,� lit j Ft., HO HAVING BEEN FIRST DULY SWORN DEPOSED AND SAYS THAT HE /SHE FULLY UNDERSTANDS THE CONTENTS OF THE AFFIDAVIT THAT HE /SHE SIGNED. ?oa,� BRIAN A. ASAY R MY COMMISSION # GG 034538 EXPIRES: October 4, 2020 Banded Mod 3L'd ?et Notany Serv:ces Notary Public Signature Notary Seal /Stamp My Commission Expires: 10 /cy /ZeZ0 Page 6 of 6 REVISED: OCTOBER 2017 I #: 2016286282 BK: 19345 PG: 874, 09/19/2016 at 01:30 PM, RECORDING 3 PAGES $27.00 D DOC STAMP COLLECTION $3500.00 KEN BURKE, CLERK OF COURT AND COMPTROLLER PINELLAS COUNTY, FL BY DEPUTY CLERK: CLK101958 Prepared By and Return To: Total Title Solutions 7311 Little Road New Port Richey, FL 34654 Order No.: CMNP16419 Property Appraiser's Parcel I.D. (folio) Number: 16- 29-15- 32274- 001 -0040 WARRANTY DEED THIS WARRANTY DEED dated September J 2016, by 2JW Group, LLC, a Florida Limited Liability Company, existing under the laws of Florida, and having its principal place of business at 404 S. MLK Jr. Ave, Clearwater, Florida 33756 (the "Grantor "), to Church of Scientology Flag Service Organization, Inc, a Florida Non -profit Corporation, whose post office address is 503 CLEVELAND ST, Clearwater, Florida, 33755 (the "Grantee "). (Wherever used herein the terms "Grantor" and "Grantee" include all the parties to this instrument and the heirs, legal representatives and assigns of individuals, and the successors and assigns of corporations) WITNESSETH: That the grantor, for and in consideration of the sum of Ten And No /100 Dollars ($10.00) and other valuable consideration, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens, remises, releases, conveys, and confirms unto the grantee, all the certain land situated in County of PINELLAS, State of Florida, viz: LOT 4 AND THE SOUTH 24 FEET OF LOT 3, BLOCK 1, OF GOULD'S AND EWING'S FIRST ADDITION TO CLEARWATER, ACCORDING TO THE PLAT THEREOF. AS RECORDED IN PLAT BOOK 1, PAGE 52, OF THE PUBLIC RECORDS OF HILLSBOROUGH COUNTY, FLORIDA. OF WHICH PINELLAS COUNTY WAS FORMERLY A PART; LESS THE WEST 25 FEET THEREOF CONVEYED TO THE CITY OF CLEARWATER FOR STREET PURPOSES BY DEED DATED JUNE 9, 1900 AND RECORDED IN DEED BOOK K2, PAGE 564, PUBLIC RECORDS OF HILLSBOROUGH COUNTY, FLORIDA, OF WHICH PINELLAS COUNTY WAS FORMERLY A PART. AND A PORTION OF LOT 3, BLOCK 1, OF GOULD AND EWING'S FIRST ADDITION TO THE CITY OF CLEARWATER, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 1, PAGE 52, OF THE PUBLIC RECORDS OF HILLSBOROUGH COUNTY, FLORIDA, OF WHICH PINELLAS COUNTY WAS FORMERLY A PART, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT A POINT ON THE EASTERLY RIGHT -OF -WAY LINE OF FORT HARRISON AVENUE, 25 FEET EAST OF THE NORTHWEST CORNER OF SAID LOT 3, BLOCK 1. OF SAID GOULD AND EWING'S FIRST ADDITION TO THE CITY OF CLEARWATER; THENCE SOUTH, ALONG THE EASTERLY RIGHT -OF -WAY LINE OF FORT HARRISON AVENUE, A DISTANCE OF 25.17 FEET TO THE POINT OF BEGINNING: DEPARTING SAID EASTERLY RIGHT -OF -WAY LINE, RUN EAST ALONG THE SOUTHERLY EXTERIOR WALL OF A ONE STORY BUILDING. A DISTANCE OF 75.38 FEET TO THE WESTERLY RIGHT- OF -WAY LINE OF WATERSON AVENUE; THENCE SOUTH, ALONG SAID WESTERLY RIGHT -OF -WAY LINE, A DISTANCE OF 1.32 FEET; THENCE, DEPARTING SAID WESTERLY RIGHT -OF -WAY LINE. RUN WEST, A DISTANCE OF 75.38 FEET TO THE EASTERLY RIGHT -OF -WAY LINE OF FORT HARRISON AVENUE; THENCE NORTH ALONG SAID EASTERLY RIGHT -OF -WAY LINE, A DISTANCE OF 0.84 FEET BACK TO THE POINT OF BEGINNING. Subject to easements, restrictions. reservations and limitations of record, if any. TOGETHER with all the tenements, hereditaments and appurtenances thereto belonging or in any wise appertaining. TO HAVE AND TO HOLD the same in Fee Simple forever. AND the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee simple; that the grantor has good right and lawful authority to sell and convey said land; that the grantor hereby fully warrants the title to said land and will defend the same against the lawful claims of all persons whomsoever; and that said land is free of all encumbrances, except taxes accruing subsequent to: 12/31/2015. PINELLAS COUNTY FL OFF. REC. BK 19345 PG 875 -C....,,.....-16–A-- : , 2JW Group. LL', a Florida imited Liability Witness Signature Compan�— BY: Joy G e BY: Samuel J Gendusa Member Wit •nature ^. Grantor Address: 404 S. MLK Jr. Ave Clearwater, FL 33756 STATE OF Florida Printed Name o Second Witness County OF Pinellas I do hereby certify that Joy Gend and Samuel J Gendusa, Members of 2JW Group, LLC, a Florida Limited Liability Company perso Ily peered before me, and who arelis personally known, or havefhas produced as identification, and acknowledged the due execution of the foregoing instrument. idand official seal, this the 1./ of September, 2016. Pudic My Commission Expires: (SEAL) PINELLAS COUNTY FL OFF. REC. BK 19345 PG 876 2JW Group, LLC, a Florida Limited Liability Company BY: Zohar Ha Member Grantor Address: 404 S. MLK Jr. Ave Clearwater, FL 33756 Signed, sealed and delivered in presence of: Witness Sign re w111g Printed Name of First Witness Witness Signature ki .k .2)RPVtAL_fs Printed Name of Second Witness STATE OF gt`r {Or\ County OF iitiu 1k(- I do hereby certify that Zohar Ha!fon, Members of 2JW Group, LLC, a Florida Limited Liability Company p onall apps pefone„ e, and who are/is personally known, or have /has produced e.n 1O(- AFC l as identification, and acknowledged the due execution of the foregoing instrument. Witness my hand and official seal, this the of September, 2016. Notary Public My Commission Expires: (NAY 4 04 Z-ot7 (SEAL) N: iaty t'ubhc - St3l, of New York NO. 010f-628241? Outhfie7 :r Hew `Irrk Coon:; !`: ?crmross�on rzp ■tes May 20, 2017 GENERAL NOTES & SPECIFICATIONS: 2 EXTERIOR SIGN ELEMENTS ON FRONT OF BUILDING 1 NON - INTERNALLY LIT BUILDING LOGO SIGN DETAILS ON SHEET SIGN 1.10 1 INTERNALLY LIT BUILDING IDENTIFICATION SIGN DETAILS ON SHEET SIGN 1.20 1 EXTERIOR SIGN NON -LIT AT BACK OF BUILDING DETAILS ON SHEET 1.30 SIGNS TO HAVE EXTERIOR GRADE PAINT FINISHES SEE DETAIL SHEETS FOR EXACT COLORS REAR OF BUILDING SIGN - SCALE: 1" = BUILDING IDENTIFICATION SIGN - SCALE: 1" = BUILDING LOGO SIGN - SCALE: 1" = WISE C LEAR WATER REAR OF BUILDING SIGN - SCALE: 1" = BUILDING IDENTIFICATION SIGN - SCALE: 1" = BUILDING LOGO SIGN - SCALE: 1" = DWG:M:IGRG FILESIFLAGICW WISE BLDG1EXTERIGRICW WISE BLDG EXTERICR.dwg ■ ,1 P SCIENTOLOGY CUSTOM MILL PROJECT: WISE CLEARWATER EXTERIOR SIGNAGE: DATE: REVISION: DRAWN BY MVH DATE: 17- Nov -17 SCALE: 1" = 1' -0" (OR AS INDICATED) SHEET No: SIGN 1.00 DWG:M:IGRG FILESIFLAGICW WISE BLDG1EXTERIGRICW WISE BLDG EXTERICR.dwg THESE AREAS FILLED WITH 2" HDU FOAM TO BE FLUSH WITH FACE6F SIGN / 72" 352" VA17[0 CLEARIWATER EQ 48" 54" EQ FRONT ELEVATION 67" WISE CLEARWATER REAR ELEVATION DWG:M:IORG FILESIFLAGICW WISE BLDG'EXTERIORICW WISE BLDG EXTERIOR.dwg At SCIENTOLOGY CUSTOM MILL PROJECT: WISE CLEARWATER EXTERIOR SIGNAGE: DATE: L REVISION: DRAWN BY MVH DATE: 17- Nov -17 SCALE: 1/4" = 1' -0" (OR AS INDICATED) SHEET No: SIGN 1.01 DWG:M:IORG FILESIFLAGICW WISE BLDG'EXTERIORICW WISE BLDG EXTERIOR.dwg WELDED ALUMINUM "CAN" BACKER ,11516" (+%2 ") / 418 "� 1/8" ALUMINUM FRONT & BACK (FACE REMOVABLE FOR INSTALLATION) W/3/32" RETURN) MODERN MASTERS ME708 NICKEL PVC FOAM DETAIL RINGS MODERN MASTERS ME708 NICKEL /-3" PVC FOAM OUTER RING MODERN MASTERS ME708 NICKEL 47" GALVANIZED OR STAINLESS STEEL BOLTS THRU BACK AND %4" STAND - OFF /SPACERS INTO FACADE OF BUILDING (MIN 4) HIGH DENSITY URETHANE FOAM DIMENSIONAL LOGO MODERN MASTERS ME230 GREEN GOLD 14' ACRYLIC DOME BENJ MOORE 434 HERB GARDEN %4' ACRYLIC TEXT MODERN MASTERS ME230 GREEN GOLD GENERAL NOTES & SPECIFICATIONS: NON - INTERNALLY LIT BUILDING LOGO SIGN SIGN CONSTRUCTION: WELDED ALUMINUM BACK "CAN" W/ REMOVABLE FACE FOR INSTALLATION W/ PVC FOAM FACE DETAIL RINGS AND ACRYLIC TEXT. DIMENSIONAL LOGO MADE OF 15LB /CUFT HDU (HIGH DENSITY URETHANE) FOAM ALL FASTENERS USED IN SIGN FABRICATION TO BE STAINLESS STEEL ALL FINISHED TO BE EXTERIOR GRADE PAINTS WISE CLEARWATER BUILDING LOGO SIGN PART MAT'L SIZE (IN) UNIT UNIT WEIGHT WEIGHT (LBS) CAN BACK& FRONT ALUMINUM 0.125 42.00 CAN RETURN ALUMINUM 0.09375 3.50 OUTER RING PVC FOAM 0.75 13.98 DETAIL RINGS PVC FOAM 0.5 1.43 DOMED FACE ACRYLYIC 0.25 SIGN1.10 18.90 DIMENSIONAL LOGO HDU 8 15.00 HARDWARE & PAINT 10.00 TOTAL SIGN WEIGHT 104.8 GALVANIZED OR STAINLESS STEEL BOLTS THRU BACK AND %4" STAND - OFF /SPACERS INTO FACADE OF BUILDING (MIN 4) HIGH DENSITY URETHANE FOAM DIMENSIONAL LOGO MODERN MASTERS ME230 GREEN GOLD 14' ACRYLIC DOME BENJ MOORE 434 HERB GARDEN %4' ACRYLIC TEXT MODERN MASTERS ME230 GREEN GOLD GENERAL NOTES & SPECIFICATIONS: NON - INTERNALLY LIT BUILDING LOGO SIGN SIGN CONSTRUCTION: WELDED ALUMINUM BACK "CAN" W/ REMOVABLE FACE FOR INSTALLATION W/ PVC FOAM FACE DETAIL RINGS AND ACRYLIC TEXT. DIMENSIONAL LOGO MADE OF 15LB /CUFT HDU (HIGH DENSITY URETHANE) FOAM ALL FASTENERS USED IN SIGN FABRICATION TO BE STAINLESS STEEL ALL FINISHED TO BE EXTERIOR GRADE PAINTS DWG:M:IORG FILESIFLAGICW WISE BLDGIEXTERIORICW WISE BLDG EXTERIOR.dwg .I SCIENTOLOGY CUSTOM MILL PROJECT: WISE CLEARWATER EXTERIOR SIGNAGE: BUILDING LOGO SIGN DATE: REVISION: DRAWN BY: MVH DATE: 17- Nov -17 SCALE: 1 1/2" = 1' -0" (OR AS INDICATED) SHEET No: SIGN1.10 DWG:M:IORG FILESIFLAGICW WISE BLDGIEXTERIORICW WISE BLDG EXTERIOR.dwg L() c 72" N 0 0 0 43.5 in 0 0 0 ACTUAL SIGNAGE SQUARE FOOTAGE: 6.3 SQ FT WISE CLEARWATER BUILDING IDENTIFICATION SIGN PART LIGHT BOX BACK & FRNT LIGHT BOX RETURNS PUSH -THRU TEXT TEXT FACES LEDS & WIRE HARDWARE & PAINT MAT'L SIZE (IN) ALUMINUM ALUMINUM ACRYLIC PVC FOAM 0.09375 0.0625 0.5 0.25 1.5/10 UNIT UNIT WEIGHT WEIGHT (LBS) 61.25 3.31 10.50 10.50 8.25 5.00 TOTAL SIGN WEIGHT 98.8 GENERAL NOTES & SPECIFICATIONS: INTERNALLY LIT BUILDING IDENTIFICATION SIGN SIGN CONSTRUCTION: WELDED ALUMINUM LIGHT BOX CONSTRUCTION W/ REMOVABLE FACE ACRYLIC PUSH THRU LETTERS W/ PVC FOAM FACES ILLUMINATION TO BE 5000K LED ALL INTERNAL WIRING TO BE DONE DURING FABRICATION AND MADE READY ALL LIGHTING AND ELECTRIC COMPONENTS TO BE UL CERTIFIED UL MARKS TO BE APPLIED TO SIGN PRIOR TO PACKAGING (FABRICATORS UL ALL FASTENERS USED IN SIGN FABRICATION TO BE STAINLESS STEEL ALL FINISHED TO BE EXTERIOR GRADE PAINTS FOR INSTALLATION & SERVICING AND FOR INSTALLATION ON SITE FILES # E486422 Vol 1.) WELDED ALUMINUM LIGHT BOX W/ DETACHABLE FACE FOR INSTALLATION AND SERVICING .090" ALUMINUM FACE & BACK %s' ALUMINUM RETURNS FINISH: MODERN MASTER ME591S PLATINUM SHADED Y;' OPTIPLEX 7328 WHITE ACRYLIC DIFFUSER INTERNAL LIGHTING SloanLED VL PLUS 2 WHITE 5000K -31 MODULES Y2" ACRYLIC PUSH -THRU LETTER FROSTED SIDES • :,•.• • a • a 2 "-4 • ;, • -! ! ! s a , a Ya" PVC FOAM LETTER FACE MODERN MASTERS ME591S PLATINUM SHADED Ya" ACRYLIC PUSH -THRU LETTER FROSTED SIDES Ya" PVC FOAM LETTER FACE MODERN MASTERS ME591S PLATINUM SHADED PLTC 2 CONDUCTOR (18 AWG) CABLE TO POWER SUPPLY (NOT TO EXCEED 15 FT) GALVANIZED OR STAINLESS STEEL BOLTS THRU BACK OF LIGHT BOX AND Ya" ACRYLIC STAND -OFF INTO BUILDING FACADE - APPROPRIATE ANCHORS TO BE USED BASED ON FACADE CONSTRUCTION Ya" WEEP HOLE @ BTM OF LIGHT BOX CLASS 2 60 W POWER SUPPLY (WET /DRY RATED) MOUNTED INSIDE BUILDING LOCATION NOT TO EXCEED 15 LF FROM SIGN • a • a . .1 o a !` • ` a • L. ! • a • ■ •• ,► • ••! • a '► - ,► o a °▪ ,b • _ •► L • ' • • • a , a • • • • a • a s • ! • • • a , a • fL• ^l • • • • • a , a -•.' , )_ • • ! ► • • ! • • s a a AIL -L' R.1 • • • P • a • • • a • Lir !` A` j7.' s . L • • • a • a • • ► A •! • '` ▪ a 5 a i, •,! s' • !• • • a • a _. f! • Ai al■ UL MARKS TO BE APPLIED TO SIGN PRIOR TO PACKAGING FABRICATORS UL FILES # E486422 Vol 1. 2 PART "SECTION SIGN" SECTION 1 - LIGHT BOX: UL MARK J 17726196 SECTION 2 - CLASS 2 POWER SUPPLY: UL MARK J 17726197 This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and /or other applicable local codes. This includes proper grounding and bonding of the sign DWG:M:WRG FILEWFLAG\CW WISE BLDGIEXTERIGRICW WISE BLDG ECTERIOR.dwg 41 P SCIENTOLOGY CUSTOM MILL PROJECT: WISE CLEARWATER EXTERIOR SIGNAGE: BUILDING IDENTIFICATION SIGN DATE: REVISION: DRAWN BY: MVH DATE: 17- Nov -17 SCALE: N.T.S. SHEET No: SIGN 1.20 DWG:M:WRG FILEWFLAG\CW WISE BLDGIEXTERIGRICW WISE BLDG ECTERIOR.dwg !01 •1010■ 1/4" THRU HOLES (X4) FOR ANCHORING TO BUILDING !GI •10101 AI •101010 O 10101010 '010101010' '0I ■10101 'OI■I0IOI0' 1011111 11:1101 '0I■IAlmn/ 1 COI ■10IDIDi OI•11110I 01•101010 0I •10101 ° 01■101010i 011110I0ID 01•10101 ■ ■IEICIID 0111EI0ID_ 0■101010 010101010 G■101010 01•101010 aaI■I0I0I0 (01■10nD' OI■ImI0I ° COI ■IOI D' 01•1130111 'OI ■IIIIOI ° I OI■10I0I 'OI ■10101 4011 110 aI■101 ■& m0101 ° � �OI■101011 Ftll■1010ID CIIMICIM 01 ■10IO ° I 1 01 ■!n!r?!n ]I ■10100 010101010 OI•1010I 01•1010I0 X01 ■10101° 01010101 ° %Z" THRU HOLE FOR POWER CABLE 1/4" WEEP HOLE @ BTM OF LIGHT BOX LED MOUNTING HOLES, POWER HOLE AND LED LAYOUT LIGHTING & POWER DATA ITEM DESCRIPTION ADD'L DATA LEDS SloanLED VL PLUS 2 WHITE 5000K MODULES QTY: 56 WATTS 30.24 POWER SUPPLY SloanLED MODW 60 WATT (X1) This sign is intended to be 'nstalled in accordance with the requirements of Article 600 of the National Electrical Code and /or other applicable local codes. This includes proper grounding and bonding of the sign DWG:M:IORG FILESWLAGCW WISE BLOGIEXTERIORICW WISE BLDG EXTERIOR.dwg ■ 1. SCIENTOLOGY CUSTOM MILL PROJECT: WISE CLEARWATER EXTERIOR SIGNAGE: BUILDING IDENTIFICATION SIGN DATE: REVISION: DRAWN BY: MVH DATE: 17- Nov -17 SCALE: N.T.S. SHEET No: SIGN 1.21 DWG:M:IORG FILESWLAGCW WISE BLOGIEXTERIORICW WISE BLDG EXTERIOR.dwg SloanLEDn Leaders In LED Technology VL Plus Whites Everyday standard face lit solutions VL Plus LED lighting system is based on proven SloanLED channel letter module design and performance. VL Plus offers a variety of solutions and a wide selection of colors. • VL Plus 2 Long is now 25% brighter • Shorts are available in 5 bright colors and 5 shades of white • Constant Current Technology (CCT) Specifications VL Plus 2 Long 2 modules per foot Part number VL Plus Short 2.5 modules per foot VL Plus Mom 4 modules per foot Dimensions La W e H Viewing angle LEDs per module VL Plus 2 Long VL Plus Short VL Plus Mini VL Plus 2 Long VL Plus Short VL Plus Mini 120° VL Plus 2 Long V Modules per foot VL Plus 2 Long V Maximum coverage per row Color 7200K,6500K 5000 K,4000K,3000K Operating temperature -40° C to +70' C Protection class Power per module V -lu •n. 0.54 W IP66 6500 K 7200 K 6500 K 701269- 6WLA2 -MB 701269- 7WSA1 -MB 701269 - WVLS -MB 3000 K 701269- 3WSA1 -MB 6500 K 701269 - WVLM -MB 3.45 in 00.49 in o 0.35 in 2.35 in a 0.49 ino0.35in 1.33 in o 0.44 in x 0.35 in 2 Can depth 5 in 5in Efficacy Power capacity Per SloanLED 60 W 12 VDC power supply: • - .. ,. les nl es Coverage 6 in 5in LED SPECIFICATIONS SloanLED Leaders in LED Technology MODW 12 VDC Power Supply IP68 -rated 60 Watt power supply The MODW 12 VDC 60 Watt power supply is designed specifically for the sign industry, incorporating innovations that speed installation and ensure reliable performance in harsh outdoor applications. The MODW is IP68 (Ingress Protection) rated to protect from dust and water intrusion, and is UL Recognized for dry, damp, and wet locations. The MODW includes improved stress tolerance in heat - sensitive components and subsystems, with unique design enhancements that strengthen electrical connections while allowing key components to flex to accommodate temperature - related expansion. • Patented end cap design for easy electrical connections and installation • Auto - resetting — No fuses to replace or circuit breaker to reset. Short circuit protection automatically resets when short condition is corrected • Simple secondary hook -ups — No minimum load, dip - switches, or load balancing required • Modular design — Cluster with standard J -boxes to create multiple 60 W legs • Rugged and compact Specifications Part number Dimensions L x W x H Nominal input voltage Maximum input current Power output Enclosure spec Operating temperature Protection class Compatibility 701507 -MODW 9.0 in 2.5 in x 1.5 in 100 -240 V 1.0A 60 W Dry, damp. and wet locations -40° C to +60° C IP68 SloanLED 12 VDC products 3i° party independent testing' Thermal shock Underwater thermal cycling Approved Approved t: us :Oui C E sP cR =r '3rd party independent testing conducted by Reliant Labs, one of the largest and busiest HALT labs in the world. 725 CI: „as Park Dr'v • Ventura. California 93003 • 805.075 3200 Fax 805 5n6.3206 • SloanLED r;urn • InfotySioanLED ccm POWER SUPPLY SPECIFICATIONS OWG:MSORG F1LESIFLAGICW WISE BLDG1EXTERIORtCW WISE BLDG EXTERIOR.dwg SCIENTOLOGY CUSTOM MILL PROJECT: CHURCH OF SCIENTOLOGY EXTERIOR SIGNAGE: LED & POWER SUPPLY SPECS DATE: REVISION: DRAWN BY: MVH DATE: 17- Nov -17 SHEET No: SIGN1.22 OWG:MSORG F1LESIFLAGICW WISE BLDG1EXTERIORtCW WISE BLDG EXTERIOR.dwg 14" or4 , WISE CLEARWATER REAR OF BUILDING SIGN WISE CLEARWATER SIZE (IN) AMT (SQFT OR LF) UNIT GENERAL NOTES & SPECIFICATIONS: NON - INTERNALLY LIT BUILDING LOGO SIGN SIGN CONSTRUCTION: PVC FOAM FRAME AROUND PVC FOAM BACKER W/ ACRYLIC FACE & ACRYLIC FLAT CUT TEXT ALL FINISHED TO BE EXTERIOR GRADE PAINTS 1" PVC FOAM FRAME BENJ MOORE OC -117 SIMPLY WHITE %2" PVC FOAM BACKER W/ CLEAT BENJ MOORE 430 LANDSCAPE %s' ACRYLIC FACE BE MOORS 1602�f GUNMETAL %4" ACRYLIC TEXT BENJ MOORE HC -172 REVERE PEWTER WISE CLEARWATER REAR OF BUILDING SIGN PART MAT'L SIZE (IN) AMT (SQFT OR LF) UNIT UNIT WEIGHT WEIGHT (LBS) OUTER FRAME PVC FOAM 0.75 0.9 SQFT 2.15 1.94 SIGN BACKER PVC FOAM 0.75 4.1 SQFT 1.43 5.86 FACE ACRYLIC 0.75 4.1 SQFT 0.37 1.50 TEXT ACRYLIC 0.5 0.5 SQFT 1.43 0.72 HARDWARE & PAINT 2.00 TOTAL SIGN WEIGHT 12.0 GENERAL NOTES & SPECIFICATIONS: NON - INTERNALLY LIT BUILDING LOGO SIGN SIGN CONSTRUCTION: PVC FOAM FRAME AROUND PVC FOAM BACKER W/ ACRYLIC FACE & ACRYLIC FLAT CUT TEXT ALL FINISHED TO BE EXTERIOR GRADE PAINTS 1" PVC FOAM FRAME BENJ MOORE OC -117 SIMPLY WHITE %2" PVC FOAM BACKER W/ CLEAT BENJ MOORE 430 LANDSCAPE %s' ACRYLIC FACE BE MOORS 1602�f GUNMETAL %4" ACRYLIC TEXT BENJ MOORE HC -172 REVERE PEWTER DWG:M:WRG FILESWLAGICW WISE BLDGIEXTERIORWW WISE BLDG EXTERIORAwy ■ SCIENTOLOGY CUSTOM MILL PROJECT: WISE CLEARWATER EXTERIOR SIGNAGE: REAR OF BUILDING SIGN DATE: 2 0 w ct DRAWN BY: MVH DATE: 17- Nov -17 SCALE: N.T.S. SHEET No: SIGN1.30 DWG:M:WRG FILESWLAGICW WISE BLDGIEXTERIORWW WISE BLDG EXTERIORAwy