Loading...
100 CORONADO DR (SOUTH TOWER)U:S. DEP`ARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1).community official, (2) insurance agenUcompany, and (3) building owner. SECTION A— PROPERTY INFORMATION FOR INSURANCE COMPANY USE A1. Building Owner's Name Policy Number: K & P Clearwater LLC A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 100 Coronado Drive (South Tower) City State ZIP Code Clearwater Florida 33767 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Tax Parcel Number 07-29-15-52380-000-0550/-0480/-0440/-0940/-0830 A4. Building Use (e.g., Residential, Non-Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 27°58'28" Long. 82°49'43" Horizontal Datum: � NAD 1927 �x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 6 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) g9,336 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 11 c) Total net area of flood openings in A8.b 208,585 sq in d) Engineered flood openings? 0 Yes ❑ No A9. For a building with an attached garage: a) Square footage of attached garage N/A sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N�q sq in d) Engineered flood openings? � Yes ❑ No SECTION B— FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 61. NFIP Community Name & Community Number B2. County Name 63. State City of Clearwater 125096 Pinellas Florida 64. Map/Panel 65. Suffix B6. FIRM Index B7. FIRM Panel 68. Flood Zone(s) B9. Base Flood Elevation(s) Number Date Effective/ (Zone AO, use Base Revised Date Flood Depth) 12103C0102 G 08/18/2009 09/03/2003 AE 11 and 12 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑ FIRM ❑ Community Determined �x Other/Source: B11. Indicate elevation datum used for BFE in Item 69: ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? � Yes ❑x No Designation Date: � CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ' � OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30, 20�8 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 100 Coronado Drive (South Tower) City State ZIP Code Company NAIC Number Clearwater Florida 33767 SECTION C— BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings" ❑ Building Under Construction* ❑x Finished Construction "A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones A1—A30, AE, AH, A(with BFE), VE, V1—V30, V(with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: AG7196 Vertical Datum: NAVD88 Indicate elevation datum used for the elevations in items a) through h) below. � NGVD 1929 � NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 4. 12 0 feet ❑ meters b) Top of the next higher floor 14 , 50 � feet � meters c) Bottom of the lowest horizontal structural member (V Zones only) N�A . ❑ feet ❑ meters d) Attached garage (top of slab) N/A , � feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building -�. $6 ❑x feet ❑ meters (Describe type of equipment and location in Comments) fl Lowest adjacent (finished) grade next to building (LAG) 4. 9 �x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 6. 6 Ox feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 9. 8 � feet ❑ meters structural support SECTION D— SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. 1 certify that the information on this Certificate represents my best efforts to interpret the data avai/ab/e. 1 understand that any fa/se statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑X Yes ❑ No ❑x Check here if attachments. Certifier's Name License Number Robert C Wright, Jr. LS 4965 Title Professional Surveyor and Mapper "�, '� ",= � r y^`' '- W; , , Company Name ' P�e co C.� _ Florida Design Consultants, Inc. ° `�a� �'t,= �; ��•� Address _. ;t�ere ,, � : 3030 Starkey Blvd. ��' ^ j c' l��� City State ZIP Code ' ���';��` ��� ' ' a: New Port Ric ey Florida 34655 Signature Date Telephone 01/10/2017 (800) 532-1047 Copy all p es of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) C2e: Elevation at the bottom of the elevator pit plunger. 610: The Base Flood Elevation shown is proposed and is per the CLOMR 14-04-0752R. A LOMR is in the process of being issued. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ' OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30, 20�8 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 100 Coronado Drive (North Tower) City State ZIP Code Company NAIC Number Clearwater Florida 33767 SECTION E— BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A(WITHOUT BFE) For Zones AO and A(without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is N�A . ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is N/A . ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is N/A , ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is N/A , ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is N�A . ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? � Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F— PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A(without a FEMA-issued or community-issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 100 Coronado Drive (South Tower) City State ZIP Code Company NAIC Number Clearwater Florida 33767 SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C(or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as-built lowest floor (including basement) of the building: . ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: , ❑ feet ❑ meters Datum G10. Community's design flood elevation: . ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6 � � BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 100 Coronado Drive (North Tower) City State ZIP Code Company NAIC Number Clearwater Florida 33767 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. �� ....� f� � � �� � � � � . � � �: � .`. � _ � � ' »�� � � '� � � ' � ,�..� � �I �t�#c� �� � � �R �� r ` ::: ����� � � � ..� A ,,i � � � � �P ` � � k .. 1 . .� ���� � �. � t �. � ' p ����� .. � � ' �. i ♦ �a ..� �� ' � � + l � . :: I � . �t . � . � �� � I � � � ry � � �� , ! ��� � ;i�.._ „ c � � ._ �� ��.�." � f � �-- � .d'Y, � . , + '� � _' _ 3 � � � � } � � �., r ;' ` . .. "�r . p:���R M . : �.. J � q 'i w t ^,MaP,, �i � L���V' '" � � �� * ' m �" �, � � _ 4' .. . . . �.. ���. : , i ��... „ _ .-c _ .. � ,. _.. . _ _. . , . t _ -� . � � s ` �� = „w +a ,.... ,... � . � �.... Photo One Photo One Caption Southwest corner lookinq Northeast (12/22/2016) ��'� �iE � �1k"��fg''�ii���iri �"rd�ti��t��"I�����it���ll�,i�i�d�i�{ �����If�������i�l��� ��� �� �� � � . s ., ,�, �� / �" �� �- � � { a � � " �f^ �� IM ;�.�- ' .�'� �� "" � � �'"' 'n �� '' .,,'' �,. �" �r ��..-- � � "'# '� A �` .r f d � � d q �a � �i � 11 '�.. � ; � " �.�i�4 � � n �� � r1 �,,,, �� � �:� ..a�� „�° rr ��11 �� � �' � � � � � � �r �� � . � �y.,t �a: .... . - . � �...:... .3 � � @ � � .. ; 4�},.. p . ����; P:. � $ � .t�i'� � Y � � t�E � v � �^ � �F ( d°'S T"^ � � i � i i � i -. + E �a . - �� P � � " ',�.. �,:Se, �yC'� � Q '�:� � L��" t ��fi��:.�� 5 . �i +t"°�. r,� » , � , :, � ...r � y . � � ., , . _ e.�. � � : � '� . , x�.�. . � , ,.. � . . . . «. � v. '£a�.... .. » ., . , : �,. .w . � ' , .. FY ... � , y� . � < .. . .+' . "�' `a� �' «aR'a� v � � ,y > . 4 .. . . ;. . . . ..... . . . ...,,. �»:. �. .:.a .�.� .« � , . ..�.. Pho[o Two Photo Two Caption Southeast corner lookinq Northwest (12/22/2016) FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 � ' BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 100 Coronado Drive (North Tower) City State ZIP Code Company NAIC Number Clearwater Florida 33767 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. Phota One Photo One Photo One Caption Phato Two Photo Two Photo Two Caption FEMA Form 086-0-33 (7/15) Replaces ali previous editions. Form Page 6 of 6 DIVISION; 08 00 00—ORENINGS SECTICIN: OS 95 43—VENTS/FOUNDATIQN FLOOD VENTS REPORT HOLDER: SMARTVENT PRCIDUCTS, INC. 430 ANDBRC� DRtVE, UNIT 1 PITMAN, NEW JERSEY 08U71 EVAI.UATION SUBJECT: SMART VENT� AUTOMATIC FOUNDATION FLOOD VENTS: FLOODVENTT"' MODEL #1540-52fl; FLOODVENT'" STACKING MODEL #1540-521; SMARTVENT'TM MODEL #1540-510; SMARNENT`"" STACKING M�DEL #1540-511; WOOD WALt FLOOD MODEL #154q-570; WOOD WA�I FLOOD OVERHEAD DOOR MODf L#1540-574; F�OODVENTTM OVERNEAD DOOR MODEL #1540-524; SMARNENTTM OVERHEAD DOOR MODEL #1540-514 ICC ICC ICC ��� ��� ��� �..._. �'�-�-- �.._.�. PMG iISTEQ Look for the trusted marks of Conformity! "2D24 Recipient of Prestigious Western States Seismic Policy Council (WSSPCJ Award in Excellence" y��.�. . ::�'i� �r�ir�ir�i A Subsidiar of ��1F�`�`������ v cou� �ou�uc ICC-ES Evc�luatia�r 2eports ar-e �rot to be constr-uec� r�,s represenlin� aest/ae�ics or• c�ny other• attributes rtr>t spec�cczll�> addr�.rsecl no�� are tlrei� to be cor�stt-r.Gec� �rs an encln�serrrent of the sr�hject of the repor�t oY a��ecommerrdation f�r its trse, � Therc is rto x�a�•rartty bt� ICC E��trla�atio�i Service, LLG, express or irnpli�zd, as to aav findin� or other nratter i�1 #his repor•t, or as tc� an�� product enver�ecf b�� the report. �� .� ,�, Copyright OO 2015 . . i � ' • � � � � Reissued February 2015 This report is subiect to renewa! February 2097. www.icc-es.orq �(800} 423-6587 �{562j 699-0543 A Subsidiary of the lnternationa/ Code Council° DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMARNENT PRODUGTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY Q8071 (877) 441-8368 www.smartvent.com #nfa(c�smartvent.cam EVALUATION SUBJECT: SMART VENT�' AUTOMATIC FOUNDATION FIOOD VENTS: �LOODVENTr"' MODEL #15d0-520; F�OODVENT'"" STACKING MODEL #1540-521; SMAR7VENTT'" MODEI. #1540-510; SMARNENTT"' STACKING MODEL #1540-511; WOOD WALL FLOOD MODEL #1540-570; WOOD WALL FLOOD OVERHEAD DOOR MOQEL #1540-574; FLOODVEN`f`T'" OVERHEAD DOOR MODEL #1540-524; SMARNENTT'" OVERHEAD DOOFt MODEL #154Q-514 1.0 EVA�UATION SGOPE Compliance vwith the following codes: ■ 20o9 and 2006 Infernationa! Bui(ding Code� (IBC) ■ 2009 and 2006 Internationa! Residentiai Coda�' (IRC) ■ 2013 Abu Dhabi lnternational Building Code (AOIBC)t iTheAQIBC is based o� the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the AOIBC. Properties evaluated: ■ Physical aperation ■ Water flaw 2.0 USES The Smart Ventffi units are automatic foundation flood vents (AFFVs) emplayed to equa�ize hydrostatic pressure on nonfire-resistance-rated foundation walls, rolling-type overhead doors and building wails subject to rising or falling flood waters. The Smart Vent° units are intended for use where flood hazard areas have been established in accordance with IBC Section 1612.3 or IRC Section R3222.1. Certain models also ailow natural ventilation in accordance with Sectian 1203 af the IBC or Section 408.1 of the IRC. 3.0 DESCRIPTION 3.1 General: When subjected to pressure from rising water, the Smart Vent�' AFFVs disengage, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The AFFV pivoting claor is normally held in the closed position by a buayant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the plate to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. The SmartVENTT'" Stacking Model #1540-511 and FloodVENTT"' Stacking Model #1540-521 units each contain two verticaily arranged openings per unit. 3.2 Engineered Opening: ihe AFFVs comply with the design principle noted in Section 2.6.2.2 of ASCE/SEI 24 for a maximum rate of rise and fall af 5.0 feet per hour (0.423 mm/s). 1n order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent AFFVs must be installed in accordance with Section 4.0. 3.3 Model Sizes: The FloodVENTTM Model #1540-520, SmartVENTT^' Model #154d-510, FloodVENTT67 Overhead Door Model #1540-524, and SmartVENTT"" Overhead Door Model #1540-514 units measure 153(a inches wide by 73l� inches high (400 by 196.9 mm). The Wood Wail Flood Model #1540-570 and Wood Wall Flood Overhead Door Model #1540-574 units measure 14 inches wide by 83/a inches high (355.6 by 222.25 mm). The SmartVENTT"' Stacking Model #1540-511 and FloodVENTr"' Stacking Model #1540-521 units measure 16 inches wide by 16 inches high (406.4 by 406.4 mm). 3.4 Ventilation: The SmartVENT� Model #1540-510 and SmartVENT° Qverhead Door Model #1540-514 both have screen covers with '/a-inch-by-'/a-inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENTT"' Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to suppiy natural ventilation. Other AFFVs recognized in this report do not offer natural ventilation. 4.0 INSTALLATION SmartVENT`� and FloodVENTT"' are designed to be installed into walls or overhead doars of existing or new cons#ruction from the exterior side. Installation of the vents must be in �ccordance with the manufacturer's instructions, the applicable code and this report. The IC'C-ES Ernli«drnn Repwvs rrre ��ot tn he catstrued ns represenling nesthetics or ai�v otlrer nttribuies not speciJicnllv addressed, nor ore d�er iu h�• ron.cuueJ ����� a� un erril�r,rrrn¢�rt o("�ha .ciibjec f aj �lre reporr or n reronunendn�ini� J'orits u.ce. The�e is �ra �currrt�iry f?i' /CC F.vri/«mrinu Srrvice, LLC. etpi e.cc nr urtpli�•J, u.v �r�.� `�' ro arn'.I��rdi�ig or nrlie�� maaer fn dris report. or as ro m�s prnduc•1 c•t���e•red hv �he report ��� � Copyright �O 2015 Page 1 of 2 ESR-2U74 � Most Wrdely Accepfed and Trusfed Page 2 of 2 mounting straps ailow mounting in wood, masonry and 5.1 concrete walls up ko 12 inches (305 mm) thick. In order to comply with the �ngineered opening design principle noted in Section 2.6.2.2 of A5CE/5E1 24, the Smart Vent�' AFFVs must be installed as fallows: ■ WitFr a minimum of two openings on different sides of each enclosed area. ■ With a minirnum of one AFFV for every 200 square feet (18.6 m2) of enclosed area, except that the SmartVENTT"" Stacki�g Model #i54Q-511 and FloodVENTT"' Stacking Modei #1540-521 rnust be installed with a minimum of one AFFV for every 400 square feet (37.2 m�) of enclosed area. ■ Be(ow the base flood elevation. ■ With the bottom of fhe AFFV located a maximum of 12 inches (305.4 mm} above grade, 5A CONDITIONS OF USE The Smart Vent� AFFVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Seetion 1.0 of this report, subject to the following canditions: 5.2 The Smart Vent�' AFFVs must be installed in accordance with this report, the applicable code and The manufacturer's instaflation instrucCions. In the event of a conflict, the instructions in this report govern. The Smart Vent� A�FVs must not be used in th� place of "breakaway walls" in coaskal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.d EVlDENCE SUBMIT7ED Data in accordance with the ICC-ES Acceptance Criteria for Automatic Foundation Fiaod Vents (AC364), dated October 2013 (editorially revised May 2014). 7.0 IDENTIFICATION The Smart VENT`� models recognized in this report must be identified by a label bearing the rnanufacturer's name (Smartvent Products, Inc.), the modei number, and the evaluation report number (E5R-2074). ICC-ES Evalua#ian Repor� ESR-2�74 FBC Supplement tssued February 2015 www.icc-es.orq ((8pQ} 423-6587 ((562) 699-0543 A Subsidiary of the Internationa/ Code Council� DIVISIQN: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. d30 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JEftSEY 08071 ($77) 441-8368 www.smartvent.corn infoCc�srnartvent.cam EVALUATION SUBJECT: SMART VENl� AUTOMATIC FOUNDATION FLOOD VENTS: FLOODVENTT"' MODEL #1540-520; FLOODVENTT"' STACKIhiG MODEL #154Q-521; SMARNENi'"' MODEL #1540-510; SMARTVENT'"' STACKING MOD�L #1540-511; WOOD WALL FLOOD MODEL #1540-570; WOOD WALL FLOOD OVEF2WEAD DOOR MODEL #1540•574; FLl70DVENTT"' OVERHEAD DOOR MOL7EL #1540-524; SMARNENTT'" OVEt2HEAQ DOOR MODEL #1540-514 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent`� Automatic Foundation FIQOd Vents, recognized in ICC-ES master report ESR-2074, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2010 Florida Building Code—Bui/dMg (FBC) ■ 2010 Fiorida Building Code—Residential (FRC) Z.0 GONCLUSIONS The Smart Vent� Automatic Foundation Fiood Vents, described in 5ections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with the FBC and the FRC, provided the design and installation are in accordance with the International Building Code'� provisions noted in the master report. Use of the Smart Vent° Automatic Foundation Flood Vents has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the FBC and the FRC for structures not subject to FBC Section 2326.3.1 or FRC Section 4409.13.3.1, as applicable. For products falling under Florida Rule 9N-3, verification that the report halder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the repo�t holder does not possess an approval by the Commission). This supplement expires concurrently with the master report reissued February 2015. 1C'C L S Ern/uatior� Rc porrs nre »ot to be caistrued as representirRg uestketics or nni orLer ntrrih�uer not .rprciJic�alt}� n�ldre.rsed, nar nre the� «, hr cni� sn neJ a.c wi exdorse�rrenr o/'tlre c�rbjer� njdic reporl or a recmm�iviidn�imi li�r rts use. Therr. i.r ua ir�u rnn{c !�clCC` Evrd�iahorr Scrvic e. /.LC, acpie.cz nr rniptieJ, a.c 5��� � to mrvTndrng or nil�cr mnn�rr in rhi.r r�pnrl, ot• �rs to anP proefuc� carered hc the r��port. ��y � Copyright OO 2015 Page 1�of 1