BCP2010-03427 (2)M/I HOMES`
mihomes.com
Monday, July 19, 2010
RE: Framing
To whom it may concern, ~`
~. _
1. Gypsum board diaphragm ceiling assembly is not aDP~c ~ir~e s ~i~ masonry
walls FBC-R702.3.7 . ~ / v II fir//
~ )
2. Framing detail, Roof to Wall connector: Detail in question indicates uplift loads for
Spruce-Pine-Fir (SPF) and the structural framing components utilized for the Varsity
Estates homes are all Southern Yellow Pine (SYP). The MTS12 used in conjunction
with SYP framing members provides a max. 1000# of uplift resistance per the
manufacturers' literature.
3. Diaphragm ceiling blocking at vaulted ceiling ridge areas shall be provided at each side
of ridge for attachment of gypsum board diaphragm component. U
4. LVL Beam: The beam in question is at the rear of the house and originally designed as `~
a 16" deep beam. The 12" deep beam installed is an acceptable substitution based on
the engineering calculations provided for review.
Owner: M/I Homes
Subdivision: Varsity Estates
M/I Homes Project #: VE005, Corsica6 w/Bonus, Elev. "B"
Please do not hesitate to contact me if you require any additional information.