CSP2012-08017A"Clearwater
Planning & Development
Department
100 South Myrtle Avenue
Clearwater, Florida 33756
Telephone: 727- 562 -4567
Fax: 727-562-4865
Ca SUBMIT ORIGINAL SIGNED AND NOTARIZED APPLICATION
® SUBMIT ONE (1) COPY OF THE FOLDED PLANS (see C, D, & E below)
® SUBMIT APPLICATION FEE $ WWW. Paid
501 S FT HARRISON AVE
CSP2012- 08017A
1
St. Luke's
Zoning: Downtown Atlas #: 295B
COMPREHENSIVE SIGN PROGRAM APPLICATION
(Revised 11.08.2012)
— PLEASE TYPE OR PRINT—
GENERAL PRINCIPLES: The intent of the Comprehensive Sign Program is to provide private property owners and businesses with flexibility to
develop innovative, creative and effective signage and to improve the aesthetics of the City of Clearwater. This program provides an alternative to
minimum standard signage subject to flexibility criteria, which ensure that signage will not have an adverse impact on the aesthetics, community
character and quality of life of the City of Clearwater.
A. PROJECT LOCATION:
PROJECT ADDRESS(ES): 501 South Fort Harrison Clearwater, FL 33756
PARCEL NUMBER(S):
16- 29 -15- 94626- 001 -0050
B. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION:
APPLICANT NAME: Dennis Powers
APPLICANT EMAIL: dpowers @creativeslgndeslgns.com
MAILING ADDRESS: 12801 Commodity Place CITY: Tampa STATE: FL Zip: 33626
PHONE NUMBER: 813 -749 -8549
PROPERTY OWNER(S): FSH7, LLC
(Must include ALL owners)
OWNER(S) EMAIL: )bhouser @stlukeseye.com
AGENT NAME: (Contact Person) Dennis Powers
AGENT EMAIL: dpowers @creativesigndesigns.com
MAILING ADDRESS: 353 Rosery Rd.
PHONE NUMBER: 813- 749 -8549
FAX NUMBER: 813- 818 -7200
CITY: Belleair STATE: FL Zip: 33756
FAX NUMBER: 813- 818 -7200
Check if AGENT is Contractor
0 Sign Contractor Name: Creative Sign Designs State License Number: ES12001069
Page 1 of 5 — Comprehensive Sign Program Application — City of Clearwater
C. PROOF OF OWNERSHIP AND SURVEY: (Code Section 4 -202 and 4 -1008)
• SUBMIT A COPY OF THE TITLE INSURANCE POLICY, DEED OR AFFIDAVIT ATTESTING TO THE OWNERSHIP OF THE PROPERTY
• PROVIDE A SIGNED AND SEALED SURVEY OF THE PROPERTY
D. SIGN PLAN AND ELEVATION PLAN SUBMITTAL REQUIREMENTS: (Code Sections 4 -202 and 4 -1008)
❑ SIGN PLANS with the following information (not to exceed 24" x 36 "):
All dimensions;
Size of site (in acreage and in square feet);
Bar scale and date prepared;
To -scale drawings in color, of all proposed signage (attached, freestanding, and directional signs), which include the following:
i. dimensions, with dimensional arrows;
ii. sign area in square feet;
iii. height and width of sign and sign structure, measured in feet;
iv. labels of all colors;
V. surface area of the sign proposed;
vi. text copy including the message of the sign;
vii. changeable copy, if proposed; and
viii. describe any illumination including the type, placement, intensity, hours of illumination and system to automatically turn off lighting
when the business is closed, and sign area to be illuminated.
Color building elevations, to scale, for all facades of any building with proposed and existing attached signage;
Master sign plan for shopping centers and office parks, to include all signs;
Site data table, to include how all proposed signs (existing and new, name each one with a title) meet code requirements, with a calculation
worksheet; and
Number, type, location and surface area of all existing signs on the same property and or building on which the sign is to be located.
E. SITE PLAN SUBMITTAL REQUIREMENTS: (Code Section & Section 4 -202 and 4 -1008)
❑ SITE PLAN with the following information (not to exceed 24" x 36"): R•
All dimensions;
North arrow;
I
Engineering bar scale (minimum scale one inch equals 50 feet), and date prepared; iI
Location map;
_ Footprint and size of all buildings and structures;
All required five -foot setbacks as measured from property line; ! �r __.. •• _._�_J
I
All existing and proposed points of access; r -1'
j ^!� ` ! 'i`
, —
All required sight triangles; - `
_-i
Location of all public and private easements and street rights -of -way within and adjacent to the site;
Location of all existing and proposed sidewalks;
Lot frontage on all rights -of -way;
Location with labels of all freestanding (including directional) signs proposed and existing (indicate whether to be removed);
Location with labels of all attached signs, proposed and existing (indicate whether to be removed);
Show all property lines;
Identification of water courses, wetlands, tree masses and specimen trees, including description and location of under story, ground cover
vegetation and wildlife habitats or other environmental unique areas;
Sight visibility triangles shown and labeled;
Location of all proposed landscape material including size and species;
Land areas expressed in square feet and acres; and
Location of the sign in relation to property lines, public rights -of -way, easements, buildings and other signs on the property.
Page 2 of 5 — Comprehensive Sign Program Application — City of Clearwater
F. WRITTEN SUBMITTAL REQUIREMENTS: (Code Section 3- 1807.C)
Signage proposed as part of a Comprehensive Sign Program may deviate from the minimum sign standards in terms of numbers of signs per
business and /or parcel of land, maximum area of sign face per parcel of land and the total area of sign faces per business or parcel of land,
subject to compliance with the flexibility criteria outlined below. As part of the program, all sign types shall be reviewed for the business and /or
the development parcel to achieve compliance in so far as possible with these current regulations. A master sign program for shopping
centers, including all out parcels, and office complexes shall include all types of signs for all tenants/uses within the development parcel.
These will be reviewed as a Comprehensive Sign Program application.
All existing and proposed signs must be architecturally integrated into the design of the building and /or site using similar and coordinated
design and style features, materials and colors, etc. Attached signs shall be horizontally and vertically proportionately located on each fagade
with no protrusions above roof lines, over windows, trim, cornices or other building features.
❑ Provide complete responses to the COMPREHENSIVE SIGN PROGRAM CRITERIA including how the criteria are met:
1. Architectural Theme. How is the design, character, location and /or materials of all signs proposed in the comprehensive
sign program demonstrably more attractive than signs otherwise permitted on the parcel proposed for development under
the minimum signs standards? Additionally, demonstrate how the proposed signage improves the community character.
Further, explain how all signs are architecturally integrated into /with the design of the building and /or site using similar and
coordinated design features, materials and colors, etc.
The signs proposed are designed to a common theme which reflects the inri'virii-jal nnS'te h, isinesses, St l-, Ike's and e, color and
materials unify the signage, enhance the building and provde necessary onsite identification. The wall mounted building signage proposed in this
application (A2) will accent the existing wall signs incorporated within the clocktower feature at the Northwest corner of the building (131 & 62). The blade
d below the existi, y clocktowe, (A!) ii icuipuidteS features f10111 the ald litedule of the building. Ail signage is black di i white,
rnnrdinating with building accents and comTolementinq the nvarall huiIdling rnlnr
2. Height. Describe how the height of all freestanding signs proposed through the Comprehensive Sign Program relate to
the design of the sign and not exceed 14 feet in height?
No freestanding signage are proposed for the site.
r`.a
No freestanding signage are proposed for the site.
3. Total Area of Sign Faces. Height, Area, Number and Location of Signs. The height, area, num �`r �{}�t)� ref >Lf ;n ,
permitted through the Comprehensive Sign Program shall be determined based on the criteria bel+,.9
_
Overall size of site: 120'x 278.5'
What is the distance in linear feet, from the building setback line to the sign location? 0'- Signs are wall mounted
What is the frontage in linear feet? 120' on Ft Harrison & 278.5' on Chestnut & Rogers
What is the proposed use? Medical Office
What is the size of the buildings (in square feet) on site? 14,500 Sq /Ft
How do pedestrians and motor vehicles access the site? Vehicle and pedestrian access to site from Chestnut & Rogers
Describe pedestrian and motor vehicular site and roadway visibility Primary visibility from Ft. Harrison and Chestnut St.
Describe the intended traffic circulation pattern: Site fronts Ft Harrison with curb cuts on Chestnut & Rogers
What is the hierarchy of signage? Al, A2, 61, 62, C
4. Elimination of Unattractive Signage. How does the signage proposed result in the elimination of existing unattractive
signage or result in an improvement to the appearance of the parcel proposed for development in comparison to signs
otherwise permitted under the minimum sign standards?
The existing pr�eCtil 1�j Siyl IS !OCated on the North ai id West buildiny eleVM4011, Mpproved tindei the revised developrinei it uIdei - 65P 12 - 08017, are
difficult to view in their current size, orientation and location. The proposed substitution of the West elevation letters are incorporated in a natural identification
location at the center apex of the wall. The projecting sign located at the Northwest corner is positioned below the exising clocktower signage, incorporates
e square teatures of e building architecture and Improves visibililty and identification o e business. I he existing projecting signage on the North and
Page 3 of 5 — Comprehensive Sign Program Application — City of Clearwater
Str or
l
CITY OF CLEARWATER
AFFIDAVIT TO AUTHORIZE AGENT
PLANNING DEPARTMENT
99�yArrt ��0 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, 2 FLOOR
PHONE (727) 562 -4567 FAX (727) 562 -4865
FSH7,LLC
(Name of all property owners)
1. That (I am /we are) the owner(s) and record title holder(s) of the following described property:
St. Luke's Cataract and Laser Institute, 501 South Fort Harrison Clearwater, FL
(Address or General Location)
2. That this property constitutes the property for which a request for a:
i
I
CSP Revision I i
I �j r
(Nature of request) - _ - .--. .....
.... -..__. _..._,_.......__.....
3. That the undersigned (has /have) appointed and (does /do) appoint Dennis Powers
as (his /their) agent(s) to execute any petitions or other documents necessary to affect such petition;
4. That this affidavit has been executed to induce the City of Clearwater, Florida to consider and act
on the above described property;
5. That (1 /we), the undersigned authority, hereby ;Pro e or ' g ' true and correct.
Property Owner
COUNTY OF PINELLAS
Before me the un�d_ersigned, an officer duly
personal) a pea,
deposes nd says th t he /she ���
-`:tip "�Y -°.Lv,
My Commission Expires:
STATE OF FLORIDA,
)mmissioned by the laws of the State of Florida, on this 1__�/ day of
I _ who having been first duly sworn
la e I vi that he /she igned
Notary Public - State of Florida
My Comm. Expires May 8, 2016
Commission N EE 173770
Bonded Through National Notary Assn. Notary Public
S:IPlanning DepartmentlApplication FormslDevelopment Review12010 Forms updated with new Department namelComprehensive Sign Program Application 5.2010. doc
Page 5 of 5 - Comprehensive Sign Program Application - City of Clearwater
5. Special Area or Scenic Corridor Plan. If the signage proposed is located in th Downtown (D) Tourist (T) district
explain how the proposed signage is consistent with the appropriate adopted design g
The building signage proposed for the St. Luke's Cataract and Laser Institute / Reflections is wall mounted. No freestanding signs are
proposed in accordance with e restrictions in the Downtown Uistrict. I ne wall mounted signage is attractive, a egan and su e.
Questions on the application? For any questions please call the City of Clearwater Planning Department at 562 -4567.
Comprehensive Sign Program
Proposed Sign Summary
Provide all information please
Address
Sign Type
Height (ft)* Length
Width
Area
or unit #
* if freestanding (ft)
(ft)
(sq.ft)
501 South Fort Harrison
Wall - EXISTING
5'- 8'
8'
42.76
501 South Fort Harrison
Wall - EXISTING
5'- 8'
8'
42.76
501 South Fort Harrison
Wall - EXISTING
2'- 10'
4'- 3"
12.4
501 South Fort Harrison
Wall-PROPOSED
4'
4'%
••AV I JUCI[1Tr•Vll rldIIIJUII
\'��%�fl rri ���r
�_v�
'r- E -e}��w
v
Sal � '�'r �►,�� �s��
dal
3' -"
`' 3 �• 6 S
0
i
IL
Page 4 of 5 — Comprehensive Sign Program Application — City of Clearwater
PLANNING Sr DEVELOPMENT
March 25, 2014
Dennis Powers
Creative Sign Designs
12801 Commodity Place
Tampa, FL 33626
CITY OF CLEARWATER
POST OFFICE BOX 4748, CLEARWATER, FLORIDA 3375748
MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756
TELEPHONE (727) 562 -4567 FAx (727) 562 -4865
RE: Development Order, Comprehensive Sign Program Amendment — CSP2012- 08017A —
501 South Fort Harrison Avenue (St. Luke's) — (related to CSP2012- 08017)
Dear Mr. Powers:
The Planning and Development Department Staff reviewed your Comprehensive Sign Program
amendment application for 501 South Fort Harrison Avenue pursuant to Community
Development Code (CDC) Section 3 -1808. The total percentage of attached sign areas on the
north and west facades is 3.29 and 2.67 percent respectively. The proposed plan includes the
addition of two attached signs and removal of two projecting signs as follows:
One Attached internally- illuminated projecting sign 16 square feet in area (0.78 percent of the
building facade area) on the north building facade attached to the northwest corner of the
building. The sign face will be white and will read "Reflections" with "Plastic Surgery"
directly underneath with "Mohs Dermatology" directly underneath with "Aesthetic Skin
Care" directly underneath all in black letters. The sign will be attached to the building via a
black decorative bracket;
2. One Attached non - illuminated flat cut -out letter sign 36.65 square feet in area (1.12 percent
of the building facade area) on the west building facade attached directly to the building
faced (no raceways). The sign will read "Reflections: with "Plastic Surgery • Aesthetic Skin
Care" directly underneath with "Mohs Dermatology" directly underneath all black in color;
3. Removal of one Attached non - illuminated projecting sign 8.4 square feet in area (0.41
percent of the building facade area) on the north building facade at the northeast corner of
the building. The sign face is black and reads "Reflections" with "PLASTIC SURGERY"
and "MOHS DERMATOLOGY" directly underneath all in while letters. The sign is attached
to the building using decorative aluminum at the top and bottom of the sign; and
4. Removal of one Attached non - illuminated projecting sign 8.4 square feet in area (0.25
percent of the building facade area) on the west building facade at the northeast corner of the
MOO,,
Pni :v F,Nwi of Nu_% i v i) Ai rini. mvr Ac nov E, vwi � )N i r.
building. The sign face is black and reads "Reflections" with "PLASTIC SURGERY" and
"MOHS DERMATOLOGY" directly underneath all in while letters. The sign is attached to
the building using decorative aluminum at the top and bottom of the sign.
The Comprehensive Sign Program has been APPROVED and this letter constitutes a
Development Order pursuant to CDC Section 4- 202.E. The approval is based on, and must be
consistent with, the site plans, elevations and drawings dated received February 03, 2014 and
February 24, 2014 as described above and subject to the following conditions:
In addition to the signs above, the following attached signs are existing and will remain on the
site:
Existing Signs
1. One Attached intemally- illuminated channel letter sign 42.76 square feet in area (2.1 percent
of the building facade area) on the north building facade attached directly to the building
facade (no raceways). The sign will read "St. Luke's" in gray letters with "LASIK ",
"CATARACT ", "RETINA" and "GLAUCOMA" immediately underneath in gray letters.
The sign will be on the clock tower approximately seven feet below the clock;
2. One Attached internally - illuminated channel letter sign 12.04 square feet in area (0.39 percent
of the building facade area) on the east building facade attached directly to the building
facade (no raceways). The sign will read "St. Luke's" in gray letters. The sign will be
centered above the entrance;
3. One Attached internally - illuminated channel letter sign 42.76 square feet in area (1.3 percent
of the building facade area) on the west building facade attached directly to the building
facade (no raceways). The sign will read "St. Luke's" in gray letters with "LASIK ",
"CATARACT ", "RETINA" and "GLAUCOMA" immediately underneath in gray letters.
The sign will be on the clock tower approximately seven feet below the clock; and
Conditions of Approval:
1. That any requests which are inconsistent with this approved Comprehensive Sign Program
require an amendment to be filed and reviewed and approved by the Planning and
Development Department prior to issuance of a building (sign) permit;
2. That the internal sign lighting for the attached signs be controlled by a mechanical timer and
be turned off at midnight or whenever the business is closed, whichever is later; and
3. That all other Code requirements /restrictions of Division 18 (Signs) be met, including but not
limited to, grand opening banners, window, temporary, construction, sale leasing signs.
Pursuant to CDC Section 4 -303, an application for a building (sign) permit shall be made within
one (1) year of the date of this Development Order (March 25, 2015). All signs shall be installed
and any conditions met within six (6) months of the date of issuance of the initial building (sign)
permit. Permitted time frames do not change with successive owners.
The issuance of this Development Order does not relieve you of the necessity to obtain any
building permits or pay any fees that may be required. In order to facilitate the issuance of any
permit or license affected by this approval, please bring a copy of this letter with you when
applying for any permits or licenses that require this prior development approval.
Should you have any questions, please contact Matt Jackson, Planner II, at (727) 562 -4504 or via
e -mail at matthew.iackson@myclearwater.com.
Sincerely,
- 6 qfl��
Gina L. Clayton
Assistant Planning and Development Director
cc: Mary Jo Weaver, Sign Inspector
CITY OF CLEARWATER
;•a °iii �-
�Q PrAN M'46 & D IN 171 OPM IN DI.PA RTWNT
POST OFFICE Boa 4748, CLEARWATER, FLORIDA 337 5841,48
jtdUSH OAq��J MUNICIPAL SI:Rvic.cs.FB'.PH(wi i,, tOO fob -iii N ymu.. AviNUE,, �.ILA�\::A71'x, FU)RIDA 33 *1 56
SH (72 ) 5G_ 45 6
February 11, 2014
DENNIS POWERS
12801 COMMODITY PLACE
TAMPA, FL 33626
VIA FAX:
RE: CSP2012- 08017A -- 501 S FT HARRISON AVE -- Letter of Completeness
Dear DENNIS POWERS:
The Planning and Development staff has entered your application into the Department's filing system
and assigned the case number: CSP2012- 08017A. After a preliminary review of the submitted
documents, staff has determined that the application is complete.
The Planning and Development Department will review the application for sufficiency by
2/18/2014.
If you have any questions, please do not hesitate to contact me at 562 -4504 or
matthew.jackson@myclearwater.com.
Sincerely yours,
Matthew Jackson
PLANNER III
2/11 /2014 Leger X_COmpleteness
°EQUAL EMPLOYMENT -kND AFFIR%TR♦ F. ACTION E4t wyn,,.°
CITY OF CLEARWATER
PLANNiN( Sr Drti�:LoPnIr��' DEP.ARTMFNT
POST OFFICE Box 47 8, CLEARWATER, FLORIDA 33758-i748
v
MUNICIPAL SL"RVITELF3UILDING. 100Sou -ni Myff 7.: ANENUE. CLEARWATER, FLORIDA 33756
C ? � . (72 ;) 562 -ii 57Ci
February 13, 2014
Dennis Powers
Creative Sign Designs
12801 Commodity Place
Tampa, FL 33626
VIA FAX:
RE: CSP2012- 08017A -- 501 S FT HARRISON AVE -- Letter of Incompleteness
Dear Dennis Powers:
The Planning Staff has entered your application into the Department's filing system and assigned the
case number: CSP2012- 08017A. After a preliminary review of the submitted documents, staff has
determined that the application is Incomplete with the following comments.
Update the reference photos to show the current sign conditions. The signs are black
not silver.
2. For the proposed projecting signs, please show the signs on a color elevation or
photograph.
3. This condition is being added as a courtesy and not a completeness condition. Only
one projecting sign will be supported.
#Error
If you have any questions, please do not hesitate to contact me at 562 -4504 or
matthew.jackson@myclearwater.com.
Sincerely yours,
Matthew Jackson
PLANNER III
2/13/2014 Letter_lr_Incompleteness
"EQUAL EMPLOYIMENT AvD AFFIRMAnw, AMON EMPI.ow.it°
PLAN VIEW ---
CUSTOM CORNER —
ALUMINUM BRACKET
BLACK
COMPREHENSIVE SIGN PROGRAM
APPROVAL.
CASE# CSPto1Z- o�o�7•q
DO ISSUED —IL I z--S / I Y
NATURE
D/F BLADE
ALUMINUM TUBE FRAME/ CLAD W /125 "ALUMINUM
PAINTED WHITE
LED LIGHT WITHIN CABINET EDGE - SLOAN / SELF CONTAINED PS
FACE TO BE .155" CLEAR / POLYCARBONITE I DECORATION
TO BE DIGITAL PRINT TRANSLIGHT W/ UV / DIFFUSER PANEL
TO BE .155 WHITE POLYCARBONITE
ACCESS FROM REMOVABLE END PANELS
51/4'
Q 4 d
4
Al 14W SCALE � .: " 0.71f NNW
If
ED
FEB 2 4 2014
PLANNING & DEVELOPMENT
69' -9"
REFERENCE PHOTO
ROOF
NOW a
E 1�
. `
Al NORTH ELEVATION
SO FT
1
2osi
a@% SO. FT.
BUILDING WALL
12MICOm dayFlan. Tames, R..tOers
P,-a. 91381 &1100
Fe•. 9u- 74s-rn
vnr.f 4,asgneeW%._n
T�.a Drewry and ao recrod.oWee
,In —,,,,e U,PfeP,r,y,,
�,° ,e'b;!aa�rold N' n;aY
channom Mn consentiY
EXISTING REVERSE
CRM /Quote:
4196 -6189
CHANNEL LETTERS
—
WITH PAINTED BLACK FA
I -1H4
EXISTING FLAT CUT OUT
42.76 SD. FT
LETTERS WITH PAINTED
o,
BLACK FACES
NOW a
E 1�
. `
Al NORTH ELEVATION
SO FT
1
2osi
a@% SO. FT.
BUILDING WALL
12MICOm dayFlan. Tames, R..tOers
P,-a. 91381 &1100
Fe•. 9u- 74s-rn
vnr.f 4,asgneeW%._n
T�.a Drewry and ao recrod.oWee
,In —,,,,e U,PfeP,r,y,,
�,° ,e'b;!aa�rold N' n;aY
channom Mn consentiY
CLIENT /ACCOUNT.
ST LUKES
CRM /Quote:
4196 -6189
W N..
>
IL Ot
J
DATE:
DESCRIPTION Approved heat
A/ND:I ORF
8pFnMIjjD ❑ Approved as noted
' ❑ Revise and resubmit
App—ad: File name:
1 -20-14
I -1H4
"114
SITE ADDRESS:
501 FORT HARRISON ST.
CLEARWATER, FL
AM:
CR
PM /PSC
CR
N
O w
1n14
Designer:
DRF
Date:
9/30/13
5
5Ul 5 F I IIAKKISUN AVt
CSP2012- 08017A
1
St. Luke's
Zoning: Downtown Atlas #: 295B
ILLUMINATED REVEL
r-
20 112"
v Re
M
r0 5 1/
5" Plastic
5'
3HANNEL LETTERS
11' -2112" _
A ections
Surgery • Mohs Dermatology
Aesthetic Skin Care
0_LETTE LAYOUT 31.11SQ. FT.
SCALE: 318 " =1' 0"
CONTRACTOR / INSTALLER TO USE APPROPRIATE HARDWARE
WALL TYPE
DESIGNATION
AM:
APPROVAL NUMBER
MASONRY
TAPCONS
—.
02 -0503.07, 00- 1201.01
Designer:
TAPCONS
art.
02 -0503.07, 00- 1201.01
9/30/13
HILTL KWICK BOLT 2
01- 1001.03
CONCRETE
ITW RAMSET /REDHEAD: TRUBOLTS WEDGE
r I —�
01 -0504.12
ANCHOR
MIAMI DADE
PLYWOOD OR
WOOD SCREWS OR LAG BOLTS
GENERIC
WOOD STUDS
ALL WALLS &
THRU BOLTS WITH FENDER WASHER AND NUTS
GENERIC
FASCIA PANELS
• THE MINIMUM EMBED DEPTH TO CONFORM WITH NOA OR OTHER APPROVED FASTENER OR ADHESIVE FOR THE
SPECIFIED WALL CONSTRUCTION. (MUST PROVIDE THE PRODUCT APPROVAL, NOTICE OF ACCEPTANCE)
12801 Commodity Place, Tampa, FL 33626 CLIENT /ACCOUNT:
Phone: 813-81 -2 11
Fax: 813- 749 -2311 ST LUKE S
www.creativesigndesigns.com
This Drawing and all reproductions
thereof are the property
Creative Sign Designs and may
not be reproduced, published,
changed or used in anyway
without written consent
SITE ADDRESS:
501 FORT HARRISON ST.
CLEARWATER. FL
MIN. LETTER STROKE 1 '12"
ART WILL REQUIRE ADJUSTMENTS
r
FLAT CUT OUT DETAIL
THREADED ROD BONDED TO
SECOND SURFACE OF LETTER
t- CAULK ADHESIVE
'FLUSH TO WALL
IWALUMINUM FLAT CUT OUT LETTER
PAINTED BLACK
SECTION DETAIL
SCALE: NTS
AUTHORITY. SEE N. E. C. ARTICLE 600. ALL
PRIMARY CONNECTIONS ARE TO BE MADE
BY LICENSED ELECTRICAL CONTRACTORS.
PRIMARY ELECTRICAL ALL PRIMARY ELECTRICAL
CONNECTIONS ARE TO MEET OR EXCEED N.E. C.
U. L. 48 OR LOCAL ENFORCING
PRIMARY WIRING SHALL BE (3) #12 THW/THWN
(BY OTHERS). GROUNDING PER. NEC ARTICLE 250
(BY OTHERS).
COMPLIANCE WITH NEC CODES AS FOLLOWS
• LISTING REQUIRED AS PER NEC 600-0
• DRAIN HOLES PER NEC 600-8 (g)
cRM /Quote. 4196 -6189
"'
u1
AM:
PM / PSC
z
CR
CR
0
Designer:
Date:
PSF
DRF
9/30/13
al.
2' 1 2 1
.063 ALUM. RETURN
WELDED TO FRON
(CAULKED)
LOW VOLTAGE LEI
AIM INTO LETTER
HALO EFFECT
A77" CLEAR POLY(
BACK
LOW VOLTAGE WI
1/2" FLEX. CONDI
CONNECTORS
.080 ALUMINUM FR
WELDED TO RETU
(CAULKED)
114" WEEP HOLES
(2) TWO PER LET
BUILDING FASCIA
MOUNTING PER. —
WALL REQUIREMENTS
8"
M SECTION DETAIL
SCALE: NTS
0
923SP N954SP
BLACK MEDIUM
IV
COLORS:
LETTER INTERIOR - --
LETTER EXTERIOR --
LED - - - - --
FRONT - - - -- --
BACK - - -- —
MOUNTING AS REQ'D.
LOW VOLTAGE WIRE
BOX & COVER
LED POWER SUPPLY
U.L. BOX& Larry Brooks, P.E. #24024
SHUTOFF SWITCH 5053 Camberley Ln.
Oldsmar, Florida 34677
2.5 AMPS (MAX) 727- 786 -9120
' /,- SEALTITE,120 VOLT 20
AMP PRIMARY ELECT. CKT.
CONNECTIONS ARE TO BE
MADE BY LICENSED ELECTRICAL
CONTRACTORS.
RECEIVED
HFEB 2094
PLANNING & DEVELOPMENT
- -WHITE
-- PAINTED SILVER BRUSHED ALUMINUM
–WHITE
- -BLACK
- CLEAR
CHANNEL LETTER CONSTRUCTION NOTES
A. Seams in returns to be at top of each letter.
B. Seal all joints inside with silicone caulking.
C. Weep holes not required for interior letters.
D. Manufactures label and U.L. Label to be on top of letters.
E. All Sealtite (Electrical out) to exit back of letter(s)
at uniform distance above bottom of each letter.
No.
DATE:
DESCRIPTION
01
1.16 -14
Al SIZE 1 DRF
02
2 -03 -14
SQ FTGS 1 JJD
COMPONENT AND CLADDING PRESSURES
PSF
FORCE COEFFICIENT DI
DESIGN WIND PRESSURE IN CONFORMANCE
W/ FBC -2010 ED REFERENCING ASCE 7.
WINU UtsIGN GNIILKIA GMAHI
WIND VELOCITY
MPH
RISK CATEGORY
EXPOSURE CATEGORY (MMRF)
INTERNAL PRESSURE COEFFICIENT
+0 0
COMPONENT AND CLADDING PRESSURES
PSF
FORCE COEFFICIENT DI
NOTES:
1. DESIGN WIND PRESSURE IN CONFORMANCE
wl FBC - 2010 ED REFERENCING ASCE 7.
SEE CHART FOR DESIGN CRITERIA PER ASCE 7 -10.
2. PRE- ENG'RED SIGN FACE BY OTHERS. DELEGATE
ENGINEER SHALL PROVIDE DESIGN DRAWINGS
3. CONTRACTOR SHALL BE RESPONSIBLE FOR
WATERPROOFING.
4. BOLTS: ASTM A307
WET LOCATION
••• NOTE:
ALL ELECTRICAL PRIMARY
CIRCUITS MUST BE DEDICATED
ISOLATED CIRCUITS
1%STEO
This sign is intended to be installed in accordance with
the requirements ofArticle 600 of the National Electric 18"S
Code and /or other applicable local codes. This includes
proper grounding and bonding of the sign.
❑ Approved
❑ Approved as noted
El Revise and resubmit
501 S FT HARRISON AVE
CSP2012- 08017A
1
St. Luke's
Zoning: Downtown Atlas #: 295B
Sheet:
FAI
FiIP name:
89D_1 -16 -14
ES1GNS i
_ 800._804.4809
4
,ASt-- CAIANAC1
•R NA•GIAI.CONA _..
10 3�.CS /z0�9
LETTER LAYOUT ,,$r1 SQ. IT
SCALE: 3/8 " =1' -0"
11' -2 112"
1 ReAections
314"
• EXISTING LETTER?
20 112"
5 „
5"-'-- Plastic Surgery • Aesthetic Skin Care
d 0 Mons Dermatology
O > 0 NEW FLAT GUT (JUT LETTER-
wi
co �
y
42.76 SQ. FT.
EXISTING REVERSE
CHANNEL LETTERS
WITH PAINTED BLACK FACES
EXISTING FLAT CUT OUT
LETTERS WITH PAINTED
BLACK FACES
17 ",
CREATIVE
SIGN DESIGNS
FLAT CUT OUT DETAIL
112
112"
CRM /Quote:
4196 -6189
THREADED ROD BONDED TO
DATE:
SECOND SURFACE OF LETTER
Sheet:
3
CAULK ADHESIVE
AM:
CR
PM / PSC
CR
FLUSH TO WALL
W ALUMINUM FLAT CUT OUT LETTER
Designer:
DRF
PAINTED BUICK
SECTION
DETAIL
SCALE:NTS
1H1N 0"
NEW LETTERS
REFERENCE PHOTO
u
bill,
WEST ELEVATION
SCALE: 3/32 " =1' -0”
3, c ? s sc �-�
✓EIVED i
9 03 294
& DEVELOPfl1ENT i
12801 Commodity Place, Tampa, FL 33526
Phone: 813 -818 -7100
Fax 813-749-2311
www.creativesigndesigns.com
This hereofarethe all reproductions
thereof are the property of
Creativepro Designs and may
not be reproduced, published,
changed or used in any way
without written consent.
CLIENT /ACCOUNT:
ST LUKES
CRM /Quote:
4196 -6189
lIJ No.
> o,
..j
-..
:!
f1i
;.�
(,J
C.,
DATE:
DESCRIPTION I Approved
_
r' Approved as noted
501 S FT HARRISON AVE Revise and resubmit
CSP2012- 08017A ed:
1
Sheet:
3
_
AM:
CR
PM / PSC
CR
SITE ADDRESS:
501 FORT HARRISON ST.
CLEARWATER, FL
Designer:
DRF
Date:
9/30/13
File name:
6189D_12 -11 -13
. unc a
Zoning: Downtown Atlas #: 295B
i
ILLUMINATED REVERSE CHANNEL LETTERS
11' -2 1/2" 2
3/4" 2
201,2" ReAlecti*ons
MIN. LETTER STROKE 1 V
LETTER LAYOUT 18.14 SQ. FT. ART WILL REQUIRE ADJUSTMENTS
SCALE: 318 " =1' -0"
0 EXISTING
CONTRACTOR /INSTALLER TO USE APPROPRIATE HARDWARE
WALLTYPE
DESIGNATION
LETTER INTERIOR - - -
APPROVAL NUMBER
MASONRY
TAPCONS
j.rrwu,rr.
02 -0503.07, 00- 1201.01
FRONT ------- - - -
TAPCONS
} �
02 -0503.07, 00- 1201.01
CONCRETE
HILTI: KWICK BOLT 2
SITE ADDRESS:
501 FORT HARRISON ST
CLEARWATER, FL
01- 1001.03 `
ITW RAMSET /REDHEAD: TRUBOLTS WEDGE
_ _
I
01- 0504.12 '
Date:
9/30/13
ANCHOR
MIAMI DADE
PLYWOOD OR
WOOD SCREWS OR LAG BOLTS
GENERIC
WOOD DS
r�wr�1•►
ALL WALLS &
THRU BOLTS WITH FENDER WASHER AND NUTS
GENERIC
FASCIA PANELS
' THE MINIMUM EMBED DEPTH TO CONFORM WITH NOA OR OTHER APPROVED FASTENER OR ADHESIVE FOR THE
SPECIFIED WALL CONSTRUCTION. (MUST PROVIDE THE PRODUCT APPROVAL, NOTICE OF ACCEPTANCE)
AUTHORITY. SEE N. E. C. ARTICLE 600. ALL
PRIMARY CONNECTIONS ARE TO BE MADE
BY LICENSED ELECTRICAL CONTRACTORS.
PRIMARY ELECTRICAL ALL PRIMARY ELECTRICAL
CONNECTIONS ARE TO MEET OR EXCEED N.E. C.
U. L. 48 OR LOCAL ENFORCING
PRIMARY WIRING SHALL BE (3) #12 THWITHWN
(BY OTHERS). GROUNDING PER. NEC ARTICLE 250
(BY OTHERS).
COMPLIANCE WITH NEC CODES AS FOLLOWS
• LISTING REQUIRED AS PER NEC 600-4
• DRAIN HOLES PER NEC 600 -8 (g)
063 ALUM. RETURN
WELDED TO FRON'
(CAULKED)
LOW VOLTAGE LEI
AIM INTO LETTER I
HALO EFFECT
.177" CLEAR POLYC
BACK
LOW VOLTAGE Wlf
1/2" FLEX. CONDU
CONNECTORS
.080 ALUMINUM FRI
WELDED TO RETUF
(CAULKED)
1/4" WEEP HOLES
(2) TWO PER LETT
BUILDING FASCIA -
MOUNTING PER.
WALL REQUIREMENTS
• 2" t 2' * 8" J
SECTION DETAIL
SCALE:NTS
1
0
923SP N954SP
BLACK MEDIUM
I
MOUNTING AS REQ'D.
LOW VOLTAGE WIRE
BOX & COVER
LED POWER SUPPLY
U.L. BOX& Larry Brooks, P.E. #24024
SHUT OFF SWITCH
5053 Camberley Ln.
Oldsmar, Florida 34677
2.5 AMPS (MAX) 727- 786 -9120
'/2" SEALTITE, 120 VOLT 20
AMP PRIMARY ELECT. CKT.
CONNECTIONS ARE TO BE
MADE BY LICENSED ELECTRICAL
CONTRACTORS.
COLORS:
WIND VELOCITY
LETTER INTERIOR - - -
-- -WHITE
LETTER EXTERIOR - - -
-- PAINTED SILVER BRUSHED ALUMINUM
LED ----- - - - - --
-WHITE
FRONT ------- - - -
- -- BLACK
BACK ------- - - - -
-- CLEAR
CHANNEL LETTER CONSTRUCTION NOTES
A. Seams in returns to be at top of each letter.
B. Seal all joints inside with silicone caulking.
C. Weep holes not required for interior letters.
D. Manufactures label and U.L. Label to be on top of letters.
E. All Sealtite (Electrical out) to exit back of letter(s)
at uniform distance above bottom of each letter.
DESIGN WIND PRESSURE IN CONFORMANCE
W/ FBC -2010 ED REFERENCING ASCE 7.
tlrrnu ucaium CRITERIA CHART
WIND VELOCITY
MPH
RISK CATEGORY
DATE:
EXPOSURE CATEGORY (MMRF)
Approved
❑ pp
❑ Approved as noted
❑Revise and resubmit
Approved:
Date:
INTERNAL PRESSURE COEFFICIENT
+0 -0
COMPONENT AND CLADDING PRESSURES
PSF
FORCE COEFFICIENT Of
NOTES:
1. DESIGN WIND PRESSURE IN CONFORMANCE
w/ FBC - 2010 ED REFERENCING ASCE 7.
SEE CHART FOR DESIGN CRITERIA PER ASCE 7 -10.
2. PRE- ENG'RED SIGN FACE BY OTHERS. DELEGATE
ENGINEER SHALL PROVIDE DESIGN DRAWINGS
3. CONTRACTOR SHALL BE RESPONSIBLE FOR
WATERPROOFING.
4. BOLTS: ASTM A307
WET LOCATION
••• NOTE:
ALL ELECTRICAL PRIMARY
CIRCUITS MUST BE DEDICATED
ISOLATED CIRCUITS
�,1STE0
This sign is intended to be installed in accordance with
the requirements ofArticle 600 of the National Electric MET
Code and /or other applicable local codes. This includes
proper grounding and bonding of the sign. US
' 12801 Commodity Place, Tampa, FL 33626
Plax:813- 749 -211
Fax: 813 -749 -2311
www.crea8vesigndesigns.com
This Drawing and all reproductions
thereof are the property of
Creative Sign Designs and may
not be reproduced, published,
chwithoutwnitenconsentay
CLIENT / ACCOUNT:
ST LUKES
CRM /Quote:
4196 -6189
1
� No.
—1
c_
U1
—
0;
-
DATE:
DESCRIPTION
Approved
❑ pp
❑ Approved as noted
❑Revise and resubmit
Approved:
Date:
Sheet:
AM:
CR
PM / PSC
CR
SITE ADDRESS:
501 FORT HARRISON ST
CLEARWATER, FL
Designer:
DRF
Date:
9/30/13
File name: