Loading...
FLD2014-03009 - STAFF REPORTClearwater MEETING DATE: AGENDA ITEM: CASE: REQUEST: GENERAL DATA: Agent........................... Owners ............................. Location .......................... Property Size .................... Future Land Use Plan...... Zoning .......................... Adjacent Zoning.... North: South: East. West. Existing Land Use ............. Proposed Land Use........ COMMUNITY DEVELOPMENT BOARD PLANNING AND DEVELOPMENT DEPARTMENT STAFF REPORT May 20, 2014 E.3 FLD2014 -03009 Flexible Development application to permit a 5,206 square foot restaurant with drive - thin facilities in the Commercial (C) District with a lot area of 55,751 square feet, a lot width of 150 feet along Gulf to Bay Boulevard, front (north) setback of 4.6 feet (to proposed pavement for bike rack pad) and 52.7 feet (to proposed building), front (west) setback of 8 feet (to proposed pavement) and 74.3 feet (to proposed building), side (south) setback of 55.5 feet (to proposed pavement) and 205.6 feet (to proposed building), side (east) setbacks of 4.5 feet (to pavement), 5 feet (to proposed pavement for dumpster pad) and 29.9 feet (to proposed building), a building height of 15.58 (to top of flat roof), 19.34 feet (to top of parapet) and 20.25 feet (to top of roof cap element) and 47 off - street parking spaces as a Comprehensive Infill Redevelopment Project pursuant to Community Development Code (CDC) Section 2- 704.E; an increase in the height of a wall in the side (east) and rear (south) setbacks from six to eight feet pursuant to CDC Section 3- 804.B.2; and a reduction to a portion of the front (north) perimeter landscape buffer from 15 feet to 4.6 feet, a reduction to the front (west) perimeter landscape buffer from 15 feet to 8 feet, a reduction to a portion of the side (east) perimeter landscape buffer from five feet to 4.5 feet, a reduction in the amount of interior landscape island trees required fiom 19 to 16, a reduction to the foundation plantings along the north and west building facades fiom five feet to zero feet and an increase in the percentage of accent trees fiom 25 to 33.3 percent, as part of a Comprehensive Landscape Program pursuant to CDC Section 3- 1202.G. Stephanie Tyrrell, McDonalds Stowell, Allan J Family Trust 2871 Gulf to Bay Boulevard; Located at the southeast corner of Gulf to Bay Boulevard and Cross Boulevard 1.28 acres Commercial General (CG) and Residential Medium (RM) Commercial (C) and Medium Density Residential (MDR) Districts Commercial (C) District Medium Density Residential (MDR) C and MDR Districts C and Medium High Density, (MHDR) ma Districts .Restaurant (Vacant) � sf�F n, Restaurant ......... m .....: ....v..w3:: PLANNING vrLOrMEVr K iearwater Level II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', ANALYSIS: Site Location and Existing Conditions: The 1.28 acre site is located at the southeast comer of Gulf to Bay Boulevard and Cross Boulevard. The property has 150 feet of frontage along Gulf to Bay Boulevard and 372.05 feet of frontage along Cross Boulevard. This site is accessed from driveways on both rights -of -way. The parcel contains a single - story building currently vacant and previously used for restaurant (Village Inn) use totaling 5,441 square feet. The majority of the site is covered by impervious surface consisting of the building and a large asphalt area to the north, south and west of the building. A total of 74 parking spaces are on the site which is seven spaces fewer than the 81 required by the vehicle sales and display use. An enclosed dumpster pad is located at the southwest comer of the parcel. There is an existing freestanding sign along the north property line that is non - conforming with regard to height that will need to be removed. The northern 372.05 feet of the property is within the Commercial (C) District; the intent and purpose of which is to provide the citizens of the City of Clearwater with convenient access to goods and services throughout the city without adversely impacting the integrity of residential neighborhoods, diminishing the scenic quality of the city or negatively impacting the safe and efficient movement of people and things within the City of Clearwater. The restaurant use is allowed in the C District but the existing structures (pavement) as well as parking are non - conforming with regard to setbacks and number provided. The landscaping on site is non - conforming with regard to widths and amount of landscaping of perimeter buffers, interior and building fagade requirements. The southern 55.5 feet of the subject property is located within the Medium Density Residential (MDR) District and only stormwater, no commercial use related 400 W 407 and Services GULF- ro-aareLM Retail Sales a C and Services n C Vacant a Attached Dwellings Community Development Board May 20, 2014 FLD2014 -03009 —Page 1 PLANNING vrLOrMEVr K iearwater l-evel II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', improvements, are proposed. The immediate vicinity is characterized by a variety of residential and non - residential lases including an established mobile home park and retail plazas to the north across Gulf to Bay Boulevard, proposed attached dwellings to the west, and a retail plaza to the east. Property to the south is vacant. The mobile home park neighborhood to the north is within the Mobile Home Park (MEP) District and the retail plazas are in the Commercial (C) District, to the east and west properties are within the Commercial (C) District and to the south properties are zoned Medium Density Residential (MDR). Development Proposal: The proposal is to demolish the existing building and dumpster enclosure to redevelop the property with 5,206 square feet of restaurant use (McDonald's) with 47 parking spaces, a new dumpster enclosure, a stormwater facility, and landscaping. The building is proposed to be constructed generally in the northeast comer of the property oriented north to south. The parking spaces will be located along the south and west side of the site. There are two driveways proposed in the general area of two existing driveways; one each on Gulf to Bay Boulevard and Cross Circle, both being two -way. A walkway will connect the sidewalk within the Gulf to Bay right -of -way to the entrance on the north side of the building. One freestanding sign is proposed on the north side of the site and attached signs are shown on all four elevation facades. Drawings of the signs which would otherwise provide such details as dimensions, area, materials color(s) and height are not included with the submittal. In short, a sign package has not been submitted with this application and signage whether indicated or not should not be considered as part of the request nor would any approval of this proposal in any way imply approval of any sign. An eight -foot wall is proposed at the southeast comer of the property. The wall will extend 90 feet north and 240 feet west. The purpose of the wall is to mitigate sound and visual impacts of the development from the properties to the east and south, specifically any proposed residential development. The wall will be designed to match the building materials and colors of the principal building. The perimeter, interior and building fagade landscaping proposed meets the provisions of Community Development Code (CDC) Article 3, Division 12, with the exception of the elimination of foundation landscaping along the north and west building facades, reduction to the widths of the north, east and west perimeter landscape buffers, a reduction to the amount of interior landscape island trees and an increase in the amount of accent trees. The applicant has mitigated these deficiencies through the provision of landscape material in excess of the minimum otherwise required by the CDC. The landscape plan includes a variety of shade, ornamental and palm trees (southern red cedar, dwarf southern magnolia, silver buttonwood, crepe myrtle, cabbage and royal palms), as well as shrubs and ground covers (yew pine, sand cord grass, viburnum and parson juniper). The buffers will be planted in such a manner as to create a tiered effect along the north and east property lines fronting the Gulf to Bay and Cross Circle rights -of -way providing adequate buffers between the subject property and adjacent rights -of -way. The proposed landscaping along the east property line is acceptable to buffer the abutting commercial uses and the landscaping along the south property line in conjunction with Community Development Board May 20, 2014 FLD2014 -03009 —Page 2 PLANNING vrLOrMEVr K iearwater Level II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', the stormwater retention facilities, provides and appropriate buffer between the proposed commercial use from any future residential development. Special Area Plan: None Development Parameters Floor Area Ratio (FAR): Pursuant to the Countywide Plan Rules and CDC Section 2- 701.1, the maximum FAR for properties with a Future Land Use Plan (FLUP) designation of Commercial General (CG) is 0.55. The proposed FAR is 0.11, which is consistent with Code provisions. Impervious Surface Ratio (ISR Pursuant to the Countywide Plan Rules and CDC Section 2- 701.1, the maximum allowable ISR is 0.90. The overall proposed ISR is 0.81 for the portion of the property with the CG designation, which is consistent with Code provisions. Minimum Lot Area and Width: Pursuant to CDC Table 2 -704, there is no minimum required lot area or lot width for a Comprehensive Infill Redevelopment Project. However, for a point of comparison, pursuant to CDC Table 2 -702, the required lot area and lot width are to be a minimum of 10,000 square feet and 100 feet, respectively. The lot area is 55,751 square feet and the lot width is 150 feet along Gulf to Bay Boulevard and 372.05 feet along Cross Circle which exceeds the otherwise minimum area and width required by Code. Minimum Setbacks: Pursuant to CDC Table 2 -704, there are no minimum required setbacks for a Comprehensive Infill Redevelopment Project. However, for a point of comparison, pursuant to CDC Table 2- 702, front and side setbacks to primary structures are 25 and 10 feet, respectively. Setbacks to parking are based upon the required landscape buffers which for the front (north and west) are 15 feet, and five feet for the side (south and east). Rear setbacks do not apply to the subject site as it is a corner lot with two front and two side setbacks under the provisions of 3- 903.D. The proposal includes front (north and west) setbacks to the building of 52.7 and 74.3, respectively. The proposed side (south and east) setbacks to building are 205.6 and 29.9 feet, respectively. The proposed setback to parking or other like vehicular use areas along the front (north and west) are proposed to be 4.6 and eight feet, respectively and 55.5 and 4.5 feet, respectively along the side (south and east) setbacks. Maximum Building Height: Pursuant to CDC Table 2 -704, there is no maximum height for a Comprehensive Infill Redevelopment Project. However, for a point of comparison, pursuant to the aforementioned CDC Table 2 -702, the maximum allowable height for restaurant uses is 25 feet. The proposed building height of 15.58 feet (to top of flat roof) is less than this allowable height and is therefore consistent with the CDC. Community Development Board May 20, 2014 FLD2014 -03009 —Page 3 PLANNING vrLOrMEVr K iearwater l-evel II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', Minimum Off-street Parkin Pursuant to CDC Table 2 -704, the minimum required parking for a Comprehensive Infill Redevelopment Project is determined by the Community Development Coordinator based on the specific use and /or ITE Manual standards. The off - street parking requirement for restaurants is between 7 and 12 spaces per 1,000 square feet of gross floor area, which for a 5,206 square foot restaurant would result in a requirement between 36 and 62 spaces. As previously noted, 47 parking spaces will be provided on site. For this reason, the applicant prepared a parking demand study which through on -site analysis of four existing McDonald's restaurants located at 1934 North Hercules Avenue, 539 South Missouri Avenue, 29978 US Highway 19 North and 1860 Gulf to Bay Boulevard that demonstrated that the proposed 47 off - street parking spaces (at a 9.03 ratio) will be adequate to meet the demand of the restaurant during all periods. As these 47 spaces are well within the acceptable range for restaurants, positive findings can be made with regard to the requested off - street parking reduction. In regards to the drive -thru facility, restaurants shall provide sufficient stacking distance to accommodate eight vehicles as measured from the first point of transaction as set forth in CDC Section 3 -1406. A typical stacking space is 18 feet in length which would require 144 feet of stacking from the first point of transaction. As there is stacking area in excess of 200 feet from the first point of transaction, the stacking area is consistent with the CDC. Mechanical Equipment: Pursuant to CDC Section 3- 201.D.1, all outside mechanical equipment must be screened so as not to be visible from public streets and /or abutting properties. Mechanical equipment will be located on the roof of the proposed building and will be concealed with parapet walls on all sides. Sight Visibility Triangles: Pursuant to CDC Section 3- 904.A, to minimize hazards at the proposed driveways on Gulf to Bay Boulevard and Cross Circle, no structures or landscaping may be installed which will obstruct views at a level between 30 inches above grade and eight feet above grade within 20- foot sight visibility triangles. This proposal has been reviewed by the City's Traffic Engineering Department and been found to be acceptable. Shrubbery planted within the sight visibility triangles will need to be maintained to meet the Code requirements. Utilities: Pursuant to CDC Section 3 -912, for development that does not involve a subdivision, all utilities including individual distribution lines must be installed underground unless such undergrounding is not practicable. The development proposal includes that all utilities are to be located underground. Landscaping: Pursuant to CDC Section 3- 1202.1), required perimeter buffers are based on adjacent uses and /or street types. Further, pursuant to CDC Section 3- 903.17, perimeter buffers to parking adjacent to rights -of -way are required to be 15 feet. The required landscape buffers are 15 feet (north — arterial street), 10 feet (west — local street) and (south — attached dwellings and like uses) and five feet (east — non - residential). In addition, Section 3- 1202.E provides that interior landscaping must be provided which is equal to or greater than 10 percent of the vehicular use area. The Community Development Board May 20, 2014 FLD2014 -03009 —Page 4 PLANNING vrLOrMEVr K iearwater Level II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', proposed vehicular use area is 27,549 square feet requiring 2,755 square feet of interior landscaped area. Section 3- 1202.E also provides that no more than 10 parking spaces may be in a row. Finally, Section 3- 1202.E requires that all facades facing a street must include a foundation planting area of at least five feet of depth along the entire fagade excluding areas necessary for ingress /egress. This proposal provides a 15 foot buffer width along the majority of the north property line with a small portion of the buffer width being 4.6 feet to accommodate a bike rack pad. Along the west property line the width is reduced to eight feet and along the east property line the width is reduced to 4.5 feet. A Code compliant buffer width is provided along the south property line. The proposal does not meet the requirements of Section 3- 1202.E in that foundation plantings along the north and east facades are not provided. The proposal also includes a reduction to the amount of interior landscape island trees required from 19 to 16 and an increase in the percentage of accent trees from 25 to 33.3 percent. As noted, the north, east and west landscape buffer widths and amount of interior landscape island trees do not meet the provisions of CDC Article 3 Division 9. The applicant has mitigated the deficiencies through the provision of landscape material in excess of the minimum otherwise required by the CDC. The landscape plan includes a variety of shade, ornamental and palm trees (southern red cedar, dwarf southern magnolia, silver buttonwood, crepe myrtle, cabbage and royal palms), as well as shrubs and ground covers (yew pine, sand cord grass, viburnum and parson juniper). The buffers will be planted in such a manner as to create a tiered effect along the north and west property lines fronting the Gulf to Bay and Cross Circle rights -of -way providing adequate buffers between the subject property and adjacent rights -of -way. The proposed landscaping along the east property line is acceptable to buffer the abutting commercial uses and the landscaping along the south property line in conjunction with the stormwater retention facilities, provides and appropriate buffer between the proposed commercial use from any future residential development. Solid Waste: A dumpster is proposed along the east property line approximately 90 feet north of the south property line. The dumpster area will be screened by a solid wall with a stucco finish to match the primary exterior color of the restaurant. The proposal has been found to be acceptable by the City's Solid Waste and Fire Departments. & nage: The proposal includes a freestanding sign as indicated on Sheet C-4.1 of the site plan. In addition, the submitted elevations indicate attached signage on all four facades. However a formal signage package has not been presented at this time. Any forthcoming signage package must meet Code requirements. Community Development Board May 20, 2014 FLD2014 -03009 —Page 5 PLANNING vrLOrMEVr K iearwater l-evel II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', Comprehensive Plan: The proposal is in support of the following Goals, Objectives and /or Policies of the City's Comprehensive Plan as follows: Future Land Use Plan Element Policy A.2.2.3 Commercial land uses shall be located at the intersection of arterial or collector streets and should be sited in such a way as to minimize the intrusion of off-site impacts into residential neighborhoods. New plats and site plans shall discourage the creation of "strip commercial" zones by insuring that adequate lot depths are maintained and by zoning for commercial development at major intersections. The proposal includes a commercial use located at the intersection of an arterial and one local street and is designed to minimize any impacts to any fiittiire residential neighborhood to the south by locating the stormwater retention area and additional landscaping at the south side of the side. As such, the proposal is largely consistent with this Policy. Objective A.3.2 — All development or redevelopment initiatives within the City of Clearwater shall meet the minimum landscaping / tree protection standards of the Community Development Code in order to promote the preservation of existing tree canopies, the expansion of that canopy, and the overall quality of development within the City; and Policy A.3.2.1 All new development or redevelopment of property within the City of Clearwater shall meet all landscape requirements of the Community Development Code. Gulf to Bay Boulevard is designated as a Primary Scenic Corridor within Section 3 -1203 of the CDC and within the Future Land Use Element (FLUE) of the City's Comprehensive Plan. Primary scenic corridors are those roadways expected to have enhanced landscape standards applied to properties along them. Furthermore, Gulf to Bay Boulevard is specifically listed as a "Corridor to Redevelop" within the Linkages section of the FLUE of the Comprehensive Plan. While the proposal does not provide the required foundation landscaping along the north fagade of the building facing Gulf to Bay Boulevard, the requisite buffer width along the front (north) property line of the site along Gulf to Bay Boulevard is demonstrably better than that as required by the minimum standards of Article 3, Division 12 of the CDC. The minimum buffer landscaping consists of a hedge and one shade tree every 35 feet. Also, and as mentioned previously, the proposed landscape plan provides for a tiered effect along the north and west sides of the site consisting of a mix of groundcovers, low- to medium -sized shrubs as well as shade, palm and ornamental trees. Therefore, the submittal supports this Objective and Policy. Policy A.5.5.1 Development should be designed to maintain and support the existing or envisioned character of the neighborhood. The proposal provides for a use permitted as a minimum development standard within the C District and a site design generally consistent with other development in the area along Gulf to Bay Boulevard. Specifically, the proposal with regard to landscaping is consistent with other properties which have been subject of Level I and Level 11 site plan approvals. In addition, the site design is consistent with the intent of the development parameters set by the Community Development Code with regard to setbacks and landscaping. These development parameters were specifically created because many areas of the City were inconsistent with the appearance and character desired by the citizens of Clearwater as evidenced by the creation and subsequent Community Development Board May 20, 2014 FLD2014 -03009 —Page 6 PLANNING vrLOrMEVr K iearwater l-evel II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', adoption of the City's current Community Development Code. Therefore, the proposal supports this Policy. Community Development Code: The proposal supports the general purpose, intent and basic planning objectives of this Code as follows: Section 1- 103.B.1. Allowing property owners to enhance the value of their property through innovative and creative redevelopment. The size, location and shape of the parcel are similar to other parcels in the area. The proposed restaurant use is consistent with the character of the area along Gulf to Bay Boulevard with regard to use and the proposal will result in a project consistent with elements of the Comprehensive Plan, as provided above. The proposed development is similar to the treatment other sites have received in the area vis -a -vis landscaping and other site improvements as mitigation to justify flexibility from certain the CDC requirements such as buffer widths and setbacks. Therefore, the proposal supports this Code section. Section 1- 103.B.2. Ensuring that development and redevelopment will not have a negative impact on the value of surrounding properties and wherever practicable promoting development and redevelopment which will enhance the value of surrounding properties. Surrounding properties to the north include retail plazas and mobile home park. Uses to the east and west include retail sales and service and proposed attached dwellings. The area to the south is vacant and zoned residential (MDR). The proposed development (McDonald's) is a national chain of restaurants desired and found in communities throughout the country. Furthermore, the proposed development provides not only for a much greater amount of landscaping than exists but a landscape plan which provides for an appearance which will be demonstrably better than the minimum otherwise required by the CDC. Furthermore, an eight -foot wall matching the materials and color of the principal building will mitigate any visual or sound impacts to any future residential developments to the south. As such, it is likely that surrounding properties will have their values enhanced. It is anticipated that the proposal will result in a positive impact on those surrounding properties. Therefore, the proposal supports this Code section. Section 1- 103.B.3. Strengthening the city's economy and increasing its tax base as a whole. The proposal includes the redevelopment of an existing vacant restaurant use with a new McDonald's restaurant. The proposal will be consistent with the character of the area with regard to size, scope and scale as compared with other properties in the neighborhood. It is largely beyond dispute that the City of Clearwater is largely built -out where the primary option for improvement is the redevelopment and /or refiirbishing of existing sites and buildings. Improving a property typically results in an increase in its value thereby positively contributing to the City's tax base and overall economy. The net result of the proposal will be another attractive redevelopment in the community which can only further interest in the improvement of surrounding properties. Therefore, the proposal supports this Code section. Section 1- 103.D. It is the further purpose of this Development Code to make the beautification of the city a matter of the highest priority and to require that existing and future uses and structures in the city are attractive and well - maintained to the maximum extent permitted by law. The proposal includes a new restaurant use with landscape buffers or portions thereof that are less than the otherwise minimum required width. The applicant has demonstrated that the Community Development Board May 20, 2014 FLD2014 -03009 —Page 7 PLAwvrLOrMEVr Clea1Materl-evelIIFlexibleDeveloP mentA PP licationReview DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', proposed building and site plan are more attractive than what is currently on the site and that the site and landscape plans are better that what would otherwise be required by the CDC. The proposal with regard to site, landscape and building design is consistent with other beautification efforts undertaken, encouraged and installed by the City and private property owners in the City as a whole and along Gulf to Bay Boulevard specifically. As discussed above, Gulf to Bay Boulevard is a designated Primary Scenic Corridor. While a specific Corridor Plan has not been adopted the intent is clear in that properties along designated Scenic Corridors such as Gulf to Bay Boulevard are expected to provide landscaping at least consistent with the minimum standards set forth by the CDC if not more. The proposal includes a landscape design which is more attractive that that as required by the minimum standards of the CDC with regard to the numbers and arrangements of plant material. As mentioned previously, the proposed landscape plan provides for a tiered effect along the north and east sides of the site consisting of a mix of groundcovers, low- to medium -sized shrubs as well as shade, palm and ornamental trees. Therefore, the proposal supports this Code section. Code Enforcement Analysis: There are no active Code Compliance cases for the subject property. COMPLIANCE WITH STANDARDS AND CRITERIA: The following table depicts the consistency of the development proposal with the standards for restaurant as per CDC Tables 2 -701.1 and 2 -704: i See analysis in Staff Report Community Development Board May 20, 2014 FLD2014 -03009 —Page 8 Standard Proposed Consistent Inconsistent Floor Area Ratio 0.55 0.11 X Impervious Surface Ratio 0.90 0.81 X Minimum Lot Area N/A 55,751 square feet (1.28 acres) X Minimum Lot Width N/A 150 feet (Gulf to Bay Boulevard) X 372.05 feet (Cross Circle) Minimum Setbacks Front: North: N/A 52.7 feet (to building) X' 4.6 feet (to paving) West: N/A 74.3 feet (to building) X' Eight feet (to paving) Side: South: N/A 205.6 feet (to building) X 55.5 feet (to paving) East: N/A 29.9 feet (to building) X' 4.5 feet (to paving) Maximum Height N/A 19.34 feet X Minimum Off- Street Parking N/A 9.03 spaces per 1,000 sq.ft. GFA X' (47 spaces) i See analysis in Staff Report Community Development Board May 20, 2014 FLD2014 -03009 —Page 8 PLANNING vrLOrMEVr K iearwater Level II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', COMPLIANCE WITH FLEXIBILITY CRITERIA: The following table depicts the consistency of the development proposal with the Flexibility criteria as per CDC Section 2- 704.C. (Comprehensive Infill Redevelopment Project): i See analysis in Staff Report Community Development Board May 20, 2014 FLD2014 -03009 —Page 9 Consistent Inconsistent 1. The development or redevelopment is otherwise impractical without deviations from X' the use and/or development standards set forth in this zoning district. 2. The development or redevelopment will be consistent with the goals and policies of X' the Comprehensive Plan, as well as with the general purpose, intent and basic planning objectives of this Code, and with the intent and purpose of this zoning district. 3. The development or redevelopment will not impede the normal and orderly X' development and improvement of surrounding properties. 4. Adjoining properties will not suffer substantial detriment as a result of the proposed X' development. 5. The proposed use shall otherwise be permitted by the underlying future land use X' category, be compatible with adjacent land uses, will not substantially alter the essential use characteristics of the neighborhood; and shall demonstrate compliance with one or more of the following objectives: a. The proposed use is permitted in this zoning district as a minimum standard, flexible standard or flexible development use; b. The proposed use would be a significant economic contributor to the City's economic base by diversifying the local economy or by creating jobs; c. The development proposal accommodates the expansion or redevelopment of an existing economic contributor; d. The proposed use provides for the provision of affordable housing; e. The proposed use provides for development or redevelopment in an area that is characterized by other similar development and where a land use plan amendment and rezoning would result in a spot land use or zoning designation; or f. The proposed use provides for the development of a new and /or preservation of a working waterfront use. 6. Flexibility with regard to use, lot width, required setbacks, height and off -street X' parking are justified based on demonstrated compliance with all of the following design objectives: a. The proposed development will not impede the normal and orderly development and improvement of the surrounding properties for uses permitted in this zoning district; b. The proposed development complies with applicable design guidelines adopted by the City; c. The design, scale and intensity of the proposed development supports the established or emerging character of an area; d. In order to form a cohesive, visually interesting and attractive appearance, the proposed development incorporates a substantial number of the following design elements: ❑ Changes in horizontal building planes; ❑ Use of architectural details such as columns, cornices, stringcourses, pilasters, porticos, balconies, railings, awnings, etc.; ❑ Variety in materials, colors and textures; ❑ Distinctive fenestration patterns; ❑ Building stepbacks; and ❑ Distinctive roofs forms. e. The proposed development provides for appropriate buffers, enhanced landscape design and appropriate distances between buildings. i See analysis in Staff Report Community Development Board May 20, 2014 FLD2014 -03009 —Page 9 PLAwvrLOrMEVr Clea1MaterLevelIIFlexibleDeveloP mentA PP licationReview DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', COMPLIANCE WITH GENERAL APPLICABILITY STANDARDS: The following table depicts the consistency of the development proposal with the General Standards for �evel Two Approvals las per CDC Section 3- 914.A: _ - I comment [wtls]: Level Two Approvals COMPLIANCE WITH COMPREHENSIVE LANDSCAPE PROGRAM STANDARDS: The following table depicts the consistency of the development proposal with the Comprehensive Landscape Program as per CDC Section 3- 1202.G: Consistent Inconsistent 1. The proposed development of the land will be in harmony with the scale, bulk, X coverage, density and character of adjacent properties in which it is located. 2. The proposed development will not hinder or discourage development and use of X adjacent land and buildings or significantly impair the value thereof. 3. The proposed development will not adversely affect the health or safety of persons X residing or working in the neighborhood. 4. The proposed development is designed to minimize traffic congestion. X 5. The proposed development is consistent with the community character of the immediate vicinity. X 6. The design of the proposed development minimizes adverse effects, including X visual, acoustic and olfactory and hours of operation impacts on adjacent properties. COMPLIANCE WITH COMPREHENSIVE LANDSCAPE PROGRAM STANDARDS: The following table depicts the consistency of the development proposal with the Comprehensive Landscape Program as per CDC Section 3- 1202.G: Community Development Board May 20, 2014 FLD2014 -03009 —Page 10 Consistent Inconsistent 1. Architectural theme. a. The landscaping in a comprehensive landscape program shall be designed as a part of the architectural theme of the principal buildings proposed or developed on the parcel proposed for development; or b. The design, character, location and/or materials of the landscape treatment X proposed in the comprehensive landscape program shall be demonstrably more attractive than landscaping otherwise permitted on the parcel proposed for development under the minimum landscape standards 2. Lighting. Any lighting proposed as a part of a comprehensive landscape program is X automatically controlled so that the lighting is turned off when the business is closed. 3. Community character. The landscape treatment proposed in the comprehensive X landscape program will enhance the community character of the City of Clearwater. 4. Property vahtes. The landscape treatment proposed in the comprehensive landscape X program will have a beneficial impact on the value of property in the immediate vicinity of the parcel proposed for development. 5. Special area or scenic corridor plan. The landscape treatment proposed in the NA NA comprehensive landscape program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the parcel proposed for development is located. Community Development Board May 20, 2014 FLD2014 -03009 —Page 10 PLANNING vrLOrMEVr K iearwater Level II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', SUMMARY AND RECOMMENDATION: - - - comment [wu2]: Bold The Development Review Committee (DRC) reviewed the application and supporting materials at its meeting of April � 03, 2014 and deemed the development proposal to be legally sufficient, - - - comment [wu3]: This maybe the wrong dace based upon the following findings of fact and conclusions of law: Findings of Fact The Planning and Development Department, having reviewed all evidence submitted by the applicant and requirements of the Community Development Code, finds that there is substantial competent evidence to support the following findings of fact: 1. That the 1.28 acre site is located at the southeast corner of Gulf to Bay Boulevard and Cross Circle; 2. That the subject property is located within the Commercial (C) and Medium Density Residential (MDR) Districts and the Commercial General (CG) and Residential Medium (RM) Future Land Use Plan categories; 3. That the subject property is not located in a special plan area; 4. That the proposal is to construct a restaurant use and is subject to the requisite development parameters pursuant to Article 2 Division 7 of the CDC; 5. That the site is currently developed with a vacant restaurant (Village Inn) use; 6. That the subject property is comprised of one parcel with 150 feet of frontage along Gulf to Bay Boulevard and 372.05 feet of frontage along Cross Circle; 7. That the proposal includes a front (north) setback of 4.6 feet (to proposed pavement for bike rack pad) and 52.7 feet (to proposed building), front (west) setback of 8 feet (to proposed pavement) and 74.3 feet (to proposed building), side (south) setback of 55.5 feet (to proposed pavement) and 205.6 feet (to proposed building), side (east) setbacks of 4.5 feet (to pavement), 5 feet (to proposed pavement for dumpster pad) and 29.9 feet (to proposed building), a building height of 15.58 (to top of flat roof), 19.34 feet (to top of parapet) and 20.25 feet (to top of roof cap element) and 47 off - street parking spaces (9.03 spaces per 1,000 square feet of Gross Floor Area); 8. That the proposal includes a reduction to a portion of the front (north) perimeter landscape buffer from 15 feet to 4.6 feet, a reduction to the front (west) perimeter landscape buffer from 15 feet to 8 feet, a reduction to a portion of the side (east) perimeter landscape buffer from five feet to 4.5 feet, a reduction in the amount of interior landscape island trees required from 19 to 16, a reduction to the foundation plantings along the north and west building facades from five feet to zero feet and an increase in the percentage of accent trees from 25 to 33.3 percent; and 9. That there are no active Code Compliance cases for the subject property. Conclusions of Law The Planning and Development Department, having made the above findings of fact, reaches the following conclusions of law: 1. That the development proposal is consistent with the pattern of development of the surrounding neighborhood; 2. That the proposal is consistent with applicable portions of the Comprehensive Plan including Future Land Use Plan Element Goal A.6, Objectives A.3.2 and A.6.4 and Policies A.2.2.3, A.3.2.1 and A.5.5.1; Community Development Board May 20, 2014 FLD2014 -03009 —Page 11 PLANNING vrLOrMEVr K iearwater Level II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', 3. That the proposal consistent with the general purpose, intent and basic planning objectives of CDC Sections 1- 103.B.1 — 3 and D.; 4. That the development proposal is consistent with the Flexibility criteria pursuant to CDC Section 2- 704.E.; 5. That the development proposal is consistent with the General Standards for �evel Two Approvals pursuant to CDC Section 3- 914.A.; and , - comment [wu4]: Level Two 6. That the development proposal is consistent with the Flexibility criteria for a Comprehensive Landscape Program pursuant to CDC Section 3- 1202.G. Based upon the above, the Planning and Development Department recommends APPROVAL of the Flexible Development application to permit a 5,206 square foot restaurant with drive -thru facilities in the Commercial (C) District with a lot area of 55,751 square feet, a lot width of 150 feet along Gulf to Bay Boulevard, front (north) setback of 4.6 feet (to proposed pavement for bike rack pad) and 52.7 feet (to proposed building), front (west) setback of 8 feet (to proposed pavement) and 74.3 feet (to proposed building), side (south) setback of 55.5 feet (to proposed pavement) and 205.6 feet (to proposed building), side (east) setbacks of 4.5 feet (to pavement), 5 feet (to proposed pavement for dumpster pad) and 29.9 feet (to proposed building), a building height of 15.58 (to top of flat roof), 19.34 feet (to top of parapet) and 20.25 feet (to top of roof cap element) and 47 off - street parking spaces as a Comprehensive Infill Redevelopment Project pursuant to Community Development Code (CDC) Section 2- 704.E; an increase in the height of a wall in the side (east) and rear (south) setbacks from six to eight feet pursuant to CDC Section 3- 804.B.2; and a reduction to a portion of the front (north) perimeter landscape buffer from 15 feet to 4.6 feet, a reduction to the front (west) perimeter landscape buffer from 15 feet to 8 feet, a reduction to a portion of the side (east) perimeter landscape buffer from five feet to 4.5 feet, a reduction in the amount of interior landscape island trees required from 19 to 16, a reduction to the foundation plantings along the north and west building facades from five feet to zero feet and an increase in the percentage of accent trees from 25 to 33.3 percent, as part of a Comprehensive Landscape Program pursuant to CDC Section 3- 1202.G., subject to the following conditions: Conditions of Approval: 1. That the final design and color of the building be generally consistent with the architectural elevations approved by the CDB; 2. That any /all fiiture signage meets the requirements of Code and be designed to match the exterior materials and color of the primary building; 3. That all nonconforming signage be removed or otherwise be brought into conformance with the CDC within one year of approval of this application request or before certificate of occupancy, whichever occurs first; 4. That issuance of a development permit by the City of Clearwater does not in any way create any right on the part of an applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the City for issuance of the permit if the applicant fails to obtain requisite approvals or fiilfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law; 5. That all other applicable local, state and /or federal permits be obtained before commencement of the development; 6. That application for a building permit be submitted no later than May 20, 2015, unless time extensions are granted pursuant to CDC Section 4 -407; Community Development Board May 20, 2014 FLD2014 -03009 —Page 12 PLANNING vrLOrMEVr K iearwater Level II Flexible Development Application Review DEVELOPNENT REVIEW DIVISION � , � ,,,, w,r,.- w, w���lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllUl�%/ �/ G///// �// p/// 00 / / / / / / / / / / / / % % / / / / /� / / / / /, %';', That prior to the issuance of any building permits, the Fire Department may require the provision of a Water Study performed by a Fire Protection Engineer in order to ensure that an adequate water supply is available and to determine if any upgrades are required by the developer due to the impact of the project. The water supply must be able to support the needs of any required fire sprinkler, standpipe and /or fire pump. If a fire pump is required, then the water supply must be able to supply 150 percent of its rated capacity; That prior to the issuance of any building permits, the location and visibility of electric equipment (electric panels, boxes and meters) be reviewed and, if located exterior to the building where visible from any street frontage, be shown to be painted the same color as the portion of the building to which such features are attached; and That prior to the issuance of any building permits; all Land Resource requirements shall be addressed. Prepared by Planning and Development Department Staff: ATTACHMENT: Resume Community Development Board May 20, 2014 FLD2014 -03009 —Page 13 Matt Jackson, Planner III