Loading...
EQUIPMENT TO ENFORCE SOUND POLICY ~ Clearwater o Parks and Recreation Department Interoffice Correspondence Sheet FROM: TO: Kevin Dunbar SUBJECT: Equipment to Enforce Sound Policy RECEIVED DATE: July 19, 2006 JUL 1 9 2006 CITY MANAGER'S OFFICE Bill, Per the worksession discussion with the Council members, I am enclosing some paperwork on equipment that is available to monitor the sound at Coachman Park. This may not be the exact model, but is an example of the type of equipment we are currently looking at to enforce the sound policy. After your review, would you pass this information onto the other Councilmembers for review. (-'J, 1f"')'! D ~' i. ......,It I) r I'..,""; ,iTY C."'''}! ...e,. \,.'; t, JUL 20 2DD6 PRESS e" FRt<IATTrHiNEV ~g{!!!!. SOUNDPRlP SEIDL _ HAND HELD SOUND LEVEL "r METER & REAL- TIME FREQUENCY ANALYZER Typical Applications · Workplace Noise Assessments · Noise Ordinance Enforcement · Environmental Noise Assessments · Hearing Protector Selection · Administrative &: Engineering Controls Selection · Task-Based Exposure Assessments The Issue The marketplace is saturated with sound level meters that provide basic summary noise data such as overall Lmin, Lmax, Leq/Lavg, Peak, Dose, Exposure, TWA and the like. These kinds of summary data can confirm that a noise problem exists but do little to help users trouble-shoot or resolve the problems found. Determining potential and most appropriate methods for correcting excessive noise levels requires a more detailed understanding of the nature of the noise. Unfortunately, obtaining more detailed information historically has meant users must deal with very complex sOllnd measurement instruments and software that are difficult to leam, a challenge to operate confidently and highly prone to operator error. For those that dare venture into the complex world of advanced noise analysis questionable measurement data and unplanned time and expense is often experienced. For the rest of us, keeping things simple may mean choosing to ignore noise problems for fear of the complexities and costs involved. The Solution Keeping things simple no longer requires compromises in the completeness of noise analysis information. The new SoundPro SE and DL Series of Hand Held Sound Level Meters and Real-Time Frequency Analyzers in combination with QuestSuite Professional II applications software is specifically designed to greatly simplify the efforts required to reliably perform advanced noise analyses. The user interface of these meters is patterned after Quest's popular NoisePro" Series Noise Dosimeters, the number one selling brand of noise dosimeter in the world and widely recognized for their ease-of- use. QuestSuite Professional II software and all models in the SoundPro SE & DL Series operate in English, Spanish, German, French, Italian and Portuguese languages. Instrument setup is as simple as a mouse click selection from a library of pre-defined and user-defined application profiles. High speed USB communications between the SoundPro SE and DL Series meters and your computer allow rapid programming and data transfers. As an added bonus, Sound Pro sE and DL Series meter data may be stored on a provided non-proprietary removable sD memory card. The sD memory card data can then be independently transferred to your computer for further analysis without taking the noise meter out of service. All soundPro SE and DL Series meters incorporate two virtual sound level meters for simultaneous measurements in accordance with multiple regulatory requirements. Meters equipped with 1/l and/or 1/3 octave real-time frequency analysis allows users to choose between RTA and broadband measurement modes for one of the virtual sound level meters. We invite you to read on to fully understand the powerful feature sets contained in the various models within the soundPro SE and DL Series. With a total of twelve available models, one is certain to match your requirements. SOU1ldPro SEIDL Series Commo1l Features SOUlldPro SOlllldPro SOlmdPro SOUlldPro SOll11dPro SOllndPro SEIDL-2 SEIDL-2-111 SEIDL-2-113 SEIDL-l SEIDLl-1/1 SEIDL-1-113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -140 dB . . . . . . es 3, 4, 5, 6 dB . . . . . . tKeypadlBacklit display . . . . . . . . . . . . \.!nlCations . . . . . . p~&:Level Triggered Start/Stop . . . . . . pefined/Named Setup Profiles . . . . . . gUsh, Spanish, German, . . . . . . Iich, Italian, Portuguese) . . . . . . . . . . . . Adva1lced Mecha1lical Desig1l Rugged, lightweight and ergonomically appealing instrument body that fits comfortably in the palm of right or left-handed users. Superior Data Display Very large backlit 128 x 64 pixel display measuring 6 cm wide by 4.8 cm tall prevents eye strain and makes measurement data clear and easy to understand. Preliminary Techllical Specificatiolls STANDARD AND APPROVALS Acoustics: EN/IEC 61672, ANSI Sl.4-1983, ANSI S1.43-1997 EN/IEC61260, ANSI S1.11-2004, ( Also fulfills all requirements of IEC 60651 and IEC 60804) EMC: Pending testing on production products. European: GENERAL 14 pushbuttons Transflective 128 x 64 dot matrix Fiber-optic English, Spanish, German, French, Italian, Portuguese SPl, MAX, MIN, Peak, ln, leq, lavg, Sel, TWA, Taktm, DOSE,PDOSE, Ldn, CNEl, Exposure Class 1: 3Hz - 22.4 kHz; Class 2: 20Hz - 8Khz; Filters: 1/1 octave (Optional); 1/3 octave (optional) SlM: (8) selectable 90 dB Dynamic Ranges. RTA: (8) selectable 80 dB Dynamic Ranges. 3dB above full scale readin A, C, Z, (Flat) Fast, Slow, Impulse Class 1; ANSI Sl.11-2004, EN/IEC61260 Center Frequencies: (1/3 Mode) 33 center frequencies from 12.5 Hz to 20 kHz. (1/1 Mode) 11 centerfrequencies from 16 Hz to 16kHz 0- 140dB 3,4,5,6dB level triggered Run/Pause, Clock/Date triggered power on and Run for programmed duration, Extemallogic input Run/Pause, Keypad initiated Run/Pause for programmed duration. 114 dB 1 kHz o degrees using a Free Field response microphone. Back.Erase: Storage System: Selectable 1 sec to 20 seconds. Removable secure digital memory card (SD-Card). Required to store multiple session/studies, setup storage, and for the datalogging option. File formats are PC compatible binary files. QuestSuite is required to interpret data files. PORTS AND CONNECTIONS Secure digital (SD) card: Used for datalogging, storing setups, and storing session/studies. Power Jack: External power supply 9-16 Vdc AC/DC output: 3.5MM stereo ( tip AC, Ring 1 DC, Ring 2 Gnd ) 10 pin auxiliary connector: RS-232, 3 digital outputs, 1 digital input USB: Conforms to USB 2.0, Mini B connector '~ / Fast & Simple Setup Ease of use is achieved through pre-defined and user-defined application setups that are loaded into the SoundPro meters with a single mouse click. & Efficient Real- Time Frequency Analysis RTA mode provides real-time display and storage of the set of 1/l or 1/3 octave spectra simultaneously. No more through each octave or 1/3 octave one at a time. Time Saving Back-Erase Utility Retains Original Data I,ifonnative Time History Profiles Optional time history data is displayed graphically in real-time and stored numerically with date and time stamps. Avoid starting tests over when noise anomalies occur in the middle of a study. Back-erase up to 20 seconds to remove anomalies from results. Retain original data as well. What You Need When You Need It ~ ~ ~y' ,"'," / '> _0 j #. ~k ~:1 ~J <'>~ ;;;r.'<", "' /} sJ"'2",., "Soft Keys" simplify operator controls by providing users with direct access to context-sensitive control functions. Non-Proprietary Removable Data Storage Media All units include an SD memory card for data storage. Data stored on SD cards appear as a removable hard drive on your PC when inserted into an SD card reader. Reporting & Exporting is a Snap What you see is what you get (yVYSIWYG) reporting is made possible by a design that allows users to select data panels to be reported and define their sequence as well. Data exporting is as simple as right-clicking on the data panel of interest and choosing the export format. Orderillg 11lfonnatilIU PART NUMBER SP-SE-2 DESCRIPTION 57-862 QuestSulte Professional" - Single User License Includes one CD and one user authorization code for installation of QuestSuite Professional II to su ort one office and one ortable PC installation within the same com an site. QuestSulte Professional" - Multi User License - Includes one CD and (1) user authorization code for installation of QuestSuite Professional II to support a total of (10) concurrent network users or (1 0) stand-alone users or any combination of the two within the same com an . QuestSuite Professional" - Unlimited User License - Includes one CD and (1) user authorization code for installation of QuestSuite Professional II to support an unlimited number of concurrent network users or stand-alone users or any combination of the two within the same company. 57-864 . Preliminary Technical Specifications (cont'd) ENVIRONMENTAL CHARACTERISTICS Temperature: Operating: Storage: Humidity: Shock & Vibration: External Fields: ( < :to.5dB effect) - 100C to + 500C -250C to + 700C TBD Magnetic:80 Nm, 50/60 Hz, no effect Electric: 10 V /m, 1 kHz modulated, 30 MHz - 1 Ghz, < 55 dBC (4) disposable AA Alkalines: 10 hours minimum continuous use depending on configuration/options. Excludes use of backlight. Voltage: 9 - 16 VDC Input: 90 - 264VAC 50/60Hz Output: 9 VDC Type/Class 2: QE7052 Type/Class 1: BK4936 (Standard) 50 Kohm nominal input impedance Directly accepts 112 in. (0.52" or 13.2 mm) microphone. Other sizes require an adapter J>reamp is removable Will dr:ive up to 30 meters of cable with negligible signal loss Greater than 1 Gohm with 1 pf loading A threaded insert on back of the meter accepts a standard 1/4" - 20 tripod mounting screw Stainless fiber filled ABS/Polycarbonate with internal EMC shielding 3.1" W x 11.1" H (w/preamp no microphone) x 1.6" Thick O.54Kg or 1.2 Ibs (including batteries) Spedfications subject to change without notice. Fur the most current spedfications and additional irifunnation abuut Qptst Technologies visit OUT web site at www.(}pest.Technologies.com. ~a.UEST. ~h:CHNOLOGIES ISO 9001 :2000 Registered Company ISO 1 7025 Accredited Calibration Lab Employee-Owned Company WORLDWIDE HEADQUARTERS 1060 Corporate Center Drive · Oconomowoc, Wisconsin 53066 USA 262-567-9157 · 800-245-0779 · Fax: 262-567-4047 www.Quest-Technologies.com 98-585 Rev. 8 6/01 /06