Loading...
300 BELCHER RD Sa CITY OF CLEARWATER - PLANNING & DEVELOPMENT SERVICES TREE REMOVAL PERMIT NAME OF OWNER /`1U JJ 714 SITE ADDRESS PHONE `�J 7 --3- OWNER'S ADDRESS LOCATION OF TREE(S) ON LOT SPECIES AND NUMBER OF TREE(S) TO APPLICANT: A non - refundable fee of $15.00 for up to five trees to be removed, plus $3.00 for every tree above 5 to be removed is required. REASON FOR REMOVAL: 0 Construction +See "A" below O Hazardous Q Declining 0 Dead ❑ Other (Specify) Fee Rec'd. $ Date A) CONSTRUCTION 1. For new construction, additions or other modifications of a property which involve the removal of a protected tree(s), a site plan is required. This site plan must have a minimum scale of 1 " =20' for single family lots, or 1 " =50' for all others. The site plan must include: a, Major Changes of Grade f. Proposed Number of Parking Spaces j. All Protected Trees including: b. Structure Locations g. Proposed Underground Utilities (L) Diameter of 4.5' above grade (DBH) c, Driveways and Walks h. Zoning Setbacks (Ii) Surveyed Location d. Parking Arrangement I. All easements and Rights -of -Way (iii.) Species e. Required Number of Parking Spaces (iv.) Diseased or Insect infested Trees k. Tree Barricade Detail & Locations 2. Protective barriers are required around all trees remaining on site during construction. These barricades must remain intact during construction. The barriers must meet City Specifications. B) REPLACEMENTS 1. Tree replacement minimum standards: l0' overall height, 2.5" caliper, Florida Grade #1. See inspectors note below to determine the number of replacement trees required. Replacements required within 30 days. I hereby certify that as property owner or as representative of the property owner, l have verified that the tree(s) sought Ahe,e oved is wholly on property owned by the above - identified property owner, and should it be determined that ) are located wholly or partially on property owned by some other person, then, I agree to hold the City of er harmless in any claim made for wrongful removal of such tree(s). I hereby certify that this application together lans submitted is a true represe ntation of all facts concerning the proposed removal of the tree(s). Any deviation r it Issued shall render it null and void and be considered a violation of the Community Development Code. of owner or appiica Printed Name Address Act. ency Representing OCL # City State Zip Phone /Cell Fax DO NOT WRITE BELOW THIS LINE - Not Valid Until Signed By City Manager or his Designated Agent Inspector's Comments: Required Replacement Trees: Applicable Code Section: Based on the Inspector's comments and information submitted, the above removal application is: Ll Approved as Submitted 0 Approved - Modified as Noted Above 0 Denied Signed: Community Development Coordinator or Designee /Inspector Date: Valid for six months from the date of issuance. ,,,,,,,,,,,,, __ %AL 1+,, oi..,,,,i_ Q, gcw%Aroc vo"nw_ Annllnrnnt Rev. 2-03 z O .00 J Q 00 D O O D L4 n T s APPLICATION FOR LAND CLEARING & GRUBBING PERMIT CITY OF CLE " PLANNING 56 M001% � 0 I N TE 1 AUG 0 ZOO7 RF�EIPT NO. A non - refundable filing fee of $10.00 is required. Permit applic te�b�y!;;W.16 , - �0M406 Qf approval. in accordance with the Community Development Code, I h ermit `td� dear and /or grub the property described below. 1. Location of Property: 3 CC) s Imo) c Lle r AA, 2. Project Name: W(A- , 6GtP I� �iG►hQe�►w S�ru� °c� S 3. Purpose of clearing and /or grubbing: 0 New Construction O Demolition 0 Tank Removal U�Other 4. General description of existing vegetation, topography, and surface water (Including all existing and /or proposed ditches, canals, and swales)} d flu I t- 5. Proposed method of debris disposal d,- yv,,A 6. Date you plan to begin work /02 7. Proposed method of soil erosion control S I �+ ►'� c e 8. 0 No -Tree Verification Required 0 Tree Removal Permit Required I AM AWARE AND UNDERSTAND THE REQUIREMENTS OF ARTICLE 3, DIVISION 12 REGARDING TREE PROTECTION DURING CONSTRUCTION AND ARTICLE 3, DIVISION 7 OF THE COMMUNITY DEVELOPMENT CODE REGARDING EROSION AND SILTATION CONTROL. A�,� Signature of Owner or Owners Representative L! \'C aS Gkova�e Printed Name 3CC-> .5. Address _ -3 3 76 City State Zip Representatives' Firm (oz ) Lfu 3- •zN-1 z. _7) F 3 t - 21Y Telephone Cell Applicant must Include Aerial Photograph or Scaled Site Plan showing property boundaries and limits of work. This is NOT a Tree Removal Permit. DO NOT WRITE BELOW THIS LINE Land Resource Comments: Based on the above comments and information submitted, the above clearing & grubbing application is: 0 Approved As Submitted 0 Approved - Modified As Noted Above 0 Denied Signed: City Manager or Designee 1362-0002 -GC Date: 10-06 m R� 1-� o� O sue. APPLICATION FOR LAND CLEARING & GRUBBING PERMIT y - CITY OF CLEARWATER PLANNING DEPARTMENT (727) 5624741 DATE RECEIPT NO. A non - refundable filing fee of $10.00 is required. Permit applicable for 6 months from date of approval. In accordance with the Community Development Code, I hereby apply for permit to land clear and /or grub the property described below. 1. Location of Property: 3 yD S • i3. 1 c �A e c 2� . 2. Project Name: tYhee(khr, )e(vkCe 3. Purpose of clearing and /or grubbing: ❑ New Construction ❑ Demolition 4 Tank Removal a Other 4. General description of existing vegetation, topography, and surface water (including all existing and /or proposed ditches, canals, and swales)- 5. Proposed method of debris disposal d - w\ D h _,J ck 6. Date you plan to begin work T / I /0 `7 7. Proposed method of soil erosion control t e 8. 0 No -Tree Verification Required ❑ Tree Removal Permit Required I AM AWARE AND UNDERSTAND THE REQUIREMENTS OF ARTICLE 3, DIVISION 12 REGARDING TREE PROTECTION DURING CONSTRUCTION AND ARTICLE 3, DIVISION 7 OF THE COMMUNITY DEVELOPMENT CODE REGARDING EROSION AND SILTATION CONTROL. Signature of Owner or Owners Representative `. W\CU010, Gkova,P, e- Printed Name 3 0c.., S. Address Ilea fwti r 1- l 3 3 76 City _ State Zip od�^5ia� C�iqheer,rt Representatives' Firm �7L7)4u3 --Z F7_2 -7) 83! -IVY Telephone C611 Applicant must Include Aerial Photograph or Scaled Site Plan showing property boundaries and limits of work. This is NOT a Tree Removal Permit. DO NOT WRITE BELOW THIS LINE Land Resource Comments: Based on the above comments and information submitted, the above clearing & grubbing application is: ❑ Approved As Submitted ❑ Approved - Modified As Noted Above 0 Denied Signed: Date: Cffy Manager or Designee I . I M2. 2- C ! 10-06 } m 3 R.� TJ n T ftw aS�Pt as , BUTLER DESIGN r KPIIQ PI INC. Butler Design Group, Inc Golden Rain Nursery, Inc Charles k Butler 4203 46" Avenue North St. Petersburg, Florida 33714 Ph (727) 521 -1684 Fax (727) 527 -7422 E -mail: txi�lic`tmnaba }__n_cm Tree Inventory Northside office Belcher Rd & Rainbow Dr Clearwater, Florida As required by the City of Clearwater, I have completed an assessment of all trees (4" dbh or greater) on the subject site and within 25' beyond the property lines. My opinion is set forth below as to the viability (rating of 1 -5) and any potential hazards of these trees. # / TRFF DRN & SPECIES / RATING AND COMMENTS 1 23" Laurel Oak 3, Extensive soil compaction, Poor structure, Mechanical damage to roots 2 i 1" Laurel Oak 2, Dead -wood, Dieback 3 11" Laurel Oak —_ 3, Compaction, Decay, Some die-back _ 4 11" Live Oak 3, Poor structure. 5 _ _ 13" Live Oak 3, Included bark, Poor structure _ 6 _ _ _ 6" Magnolia 3, Poor structure, _ 17 8 — 13" Live Oak 12" Live Oak 3, Included bar'x_, Epicormic grow-th 3, Co- dominate, Included bark, Cross brat.zching _ _ ff' I affirm that my opinions have been made in good faith, with no coercion from others. I further affirm that I have no interest with the parties or people involved with neither this issue nor any interest with regard to the outcome. Sincerely, Chuck Butler, Certified Arborist, Certificate #FL -1235A Butler Design Group/ Golden Rain Nursery, Inc. ■ ■ V ■ �■ Z V Q. ■ 0 O o ■ LU O rrnn ■ yJ ■ P ■ ALT C ■ ■ I O II � A S P H A L T ® CB 4 Conocarpu5 erectu5 5ericeu5 51lver Buttonwood 30 gal 2 "Cal 8'oa 51ngle stem (I IN 18 Ilex x 'Nellie R. 5teven5" Nellie R. Stevens Holly 30 gal 2 "Cal 8'oa CM L� iwi� IstIVVI:EIv 61kEk1 FOR INTERIOR ISILANDS LANDSCAPE PL .AN "� r;AVEIVIEN �;ND'ARKING L01 �.�f�P��'�[� `��` �'`�4 ; � � 4'I 4 "0 SE TURFED OR RECEIVE OTH��,, I- AINIDSC PING TRFATWIF T gg / t' 14i r'flil�f �OC /9 .Q�����+E�� "F i t� LI 4 Lagemtroemia indica 'Lavender' Crape Myrtle 45 gal 2 "Cal 8'oa 51ngle stem ALL LANDSCAPING TO BE PROTECTED =� FROM VEHICULAR OR PEDESTRIAN ANY ChANGES IN 4VLCIE�1, ma TRAFFIC BY A MINIMUM SIX INCH SPECIFICATIONS, OR DESIGN' • MC 2 Myrica cerifera Wax Myrtle 45 gal 2 "Cal 8'oa Multi -stem QH5. PO 2 Platanu5 occidentah5 Sycamore 45 gal 2.5 "Cal 10' oa CODE QTY BOTANICAL COMMON CONT FIELD2 REMARK5 eDE 97 Duranta erecta 'Gold Mound' Gold Mound Duranta 3 gal 24 "oa PP 14 Philodendron xanadu Philodendron 3 gal 18" 5V 52 5chefflera arboricola "Trinette" Variegated Arboricola 3 gal 24 'oa V5 81 Viburnum 5u5pen5um 5andankwa Viburnum 3 gal 24 "oa GROUND COVER 5HRU135 CODE QTY BOTANICAL COMMON CONT FIELD2 REMARK5 <0 DB 68 Dianella tasmanica ' Blu5hy' Varigated Flax Lily I gal 18" lints JP 13 Juniperu5 chmen5i5 ' Parsonn' Pamoni Juniper I gal 12' Runners 'j RA 26 Rhaphiolep15 indica 'Alba' White Indian Hawthorn 3 gal 14" ASPHALT PAVEMENT All landscaping must be properly installed per approved plan prior to CO inspection. R*q)gdM tees are ff anddW PLANT 5CHEDULE LOW GROUND COVER5 QTY BOTANICAL COMMON CONT DETAIL REMARK5 Q 12" 2_ 170 Trachelo5permum a5iaticum "Minima" Dwf. Jasmine I gal I /L I .2 5OD/5EED QTY BOTANICAL COMMON CONT DETAIL REMARKS ❑ 12" 716 5f f a5palum notatum 'Argentine' Bahia Grass sod BUSH 168 5f 5tenotaphrum 5ecundatum 'Florham' ' Floritam' 5t. Augu5tine 5od sod G Of Clw. LANDSCAFE TkEMMEN i FEQUIkEV CM L� iwi� IstIVVI:EIv 61kEk1 FOR INTERIOR ISILANDS LANDSCAPE PL .AN "� r;AVEIVIEN �;ND'ARKING L01 �.�f�P��'�[� `��` �'`�4 ; � � 4'I 4 "0 SE TURFED OR RECEIVE OTH��,, I- AINIDSC PING TRFATWIF T gg / t' 14i r'flil�f �OC /9 .Q�����+E�� "F i t� P 1 � CMZ IVC1�1 Tdi{� eridi .. 7/1 %D a �LL. W ALL LANDSCAPING TO BE PROTECTED =� FROM VEHICULAR OR PEDESTRIAN ANY ChANGES IN 4VLCIE�1, ma TRAFFIC BY A MINIMUM SIX INCH SPECIFICATIONS, OR DESIGN' / / y6 ' Il`HtK1T THE CONSENT OF 51:. HIGH CURBING AND WHEEL STOPS PLANNING DIRECTOR r1EP10 ,% Z M0 21 I V C' 0 ti d NORTH 0 10 20 30 feet 7LrL:m�� 7 SCALE: 1" = 10' z I g480 M V O F v � 4P3 0 M �z M Ili 1- • �0 • �rz AU z ^� • 0 W > Wt4 z W • 0 M MY W` N ii. ` Y► z aM • IL F ZVA ch z j 1m W • >3 W1 6 #5936 v ES Comm.: 2007 -P Drawn By: B.J.V. Checked By: H.G. TREE LEGEND Q 12" OAK TREE 0 12" PINE TREE 12" PALM TREE ❑ 12" OTHER TREE (AS LABELED) Q BUSH ® HOLLY BUSH V C' 0 ti d NORTH 0 10 20 30 feet 7LrL:m�� 7 SCALE: 1" = 10' z I g480 M V O F v � 4P3 0 M �z M Ili 1- • �0 • �rz AU z ^� • 0 W > Wt4 z W • 0 M MY W` N ii. ` Y► z aM • IL F ZVA ch z j 1m W • >3 W1 6 #5936 v ES Comm.: 2007 -P Drawn By: B.J.V. Checked By: H.G. Z 45 CL W H CO) W CLS V co D Z 5 [BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 - 521 -1684, FAX: 727 - 527 -7422, E -MAIL: RONSPLANSOTAMPABAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist : FL -1235A v ssue Date: 4 -24-07 Revisions: No. Date Description 15/07 City Comments 10114/0 City Comments 1/24108 Per Pin. Co. ® 7109108 G Of Clw. CM W W Z � 0 CMZ O Z �LL. W W =� v I— Cn ma D / / y6 Z 45 CL W H CO) W CLS V co D Z 5 [BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 - 521 -1684, FAX: 727 - 527 -7422, E -MAIL: RONSPLANSOTAMPABAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist : FL -1235A v Z W V CM W W Z � 0 CMZ O Z �LL. W W =� v I— Cn ma � y6 Z M0 L1.11 WATER WELL: 4" HIGH AT SHRUB, NO WATER WELL AT LAWN AREA. =r, r =I I 1- Zo - III =III: N ZOJ llll� lll_ + OQ< J,¢0 Q C7 � u7 o; �Q¢ o; ¢ ROOTBALL 2 X ROOTBALL 12" AT 1 GALLON 22" AT 5 GALLON 32" AT 15 GALLON SHRUB PLANTING 1 " = 1' -0" AERIAL GUY CABLES TO CONNECT TRUNKS: 9 GA CABLE W/ CLEAR PLASTIC COATING THRU 5/8' DIA. RUBBER HOSE TIE. SEE PLANT PIT DETAIL. SET ROOTBALL CROWN 1 " HIGHER THAN SURROUNDING FINISHED GRADE. SLOPE FINISHED GRADE AT BACKFILL AWAY FROM ROOTBALL. MULCH TO 2" DEPTH AT WATER WELL. F- FINISHED GRADE, PLANT TABLETS AS NOTED OR SPEICIFIED. BACKFILL MIX, SEE NOTES AND SPECIFICATIONS, NATIVE SOIL MIX FIRMLY COMPACTED. 32 9333.13 -01 STAKING DETAIL SET ROOTBALL CROWN 1 112" HIGHER THAN THE SURROUNDING FINISHED GRADE. SLOPE BACKFILL AWAY FROM ROOTBALL FOR POSITIVE DRAINAGE. PLANTING AT y PLANTING AT TURF AREAS. SHRUB AREAS. KEEP TURF CLEAR FOR A 18" KEEP MULCH 6" - 8" RADIUS CIRCLE AROUND THE FROM BASE OF TREE, TREE. MULCH WITH A 3 THICK LAYER OF SHREDDED BARK. MULCH WATER WELL AREA TO 3" DEPTH. RECESS TURF AREA 6" HIGH WATER 1 TO ALLOW FOR MULCH. WELL AT SHRUB AREAS. FINISHED GRADE AT LAWN. ( -II FINISHED GRADE AT SHRUBS. � x x -ICI =_ ICI- III -_ -= + ;mmm I:II�I =II II= III =I�I�I�I� -1 Q Ln N ° -� I I - -, ROOTBALL ;III - 0 ¢QQ ¢ O PLANT TABLETS AS I N N N N o NOTED OR SPEICIFIED, BACKFILL MIX, SEE 2X ROOTBALL NOTES AND SPECIFICATIONS. 32" AT 15 GALLON NATIVE SOIL MIX 48" AT 24" BOX FIRMLY COMPACTED. 60" AT 30" BOX 72" AT 36" BOX PLANT PIT DETAIL 2 TREE PLANTING MULTI -STAKE 32 9343.23 -03 TREE BARRICADE DETAIL I-/ U� 6' -8' 4' 1 " X 4" Horizontal Wood Members or Approved Substitute Barriers Placed at Protective Radius 2 /3rd's dripline for hardwoods (6'min) full dripline for pines (6'min) TREE BARRICADE DETAIL N.T.S. 10 GAUGE GALV. CABLE W/ TURNBUCKLE & CLEAR PLASTIC COATING 3 "x12" WOOD OR METAL FLAG, PAINTED WHITE. 45 DEG TYPICAL STAKING DETAIL PLANTING AT TURF AREAS. KEEP TURF CLEAR FOR A 18 ", RADIUS CIRCLE AROUND THE TREE. MULCH WITH A 3" THICK LAYER OF SHREDDED BARK. RECESS TURF AREA 1 " TO ALLOW FOR MULCH. FINISHED GRADE AT LAWN. xx x x'I_I =III + MMomom 11 =� J _ _ J d- O c0 00 ¢ N r7 n d M ~ l­-l�� O ¢¢¢¢ o Of ao �t o i- Nn d d 3" THICK GRAVEL BED V AS BASE OF PLANT PIT. FOUR 48" DIAMETER X 48" DEEP AUGERED HOLES FILLED WITH GRAVEL. PLANT PIT DETAIL ROOTBALL ROOTBALL as &o 2" x 2" Vertical Wood Stakes 12" LONG X 5/8" DIAMETER REINFORCED HOSE OVER WIRE ® TRUNK (TYP.) 1 " DIA. X 36" GALV. IRON PIPE ANCHOR W/ CAP ON TOP. ONE AT EACH TIE (3 REQ.) TOP OF PIPE TO BE 1" BELOW FINISHED GRADE FINISHED PLANTING AT SHRUB AREAS. SET ROOTBALL CROWN 1-1/2" HIGHER THAN THE SURROUNDING FINISHED GRADE. SLOPE BACKFILL AWAY FROM ROOTBALL FOR POSITIVE DRAINAGE. KEEP MULCH 6" - 8" FROM BASE OF TREE. MULCH WATER WELL AREA TO 3" DEPTH. 6" HIGH WATER WELL AT SHRUB AREAS. I -I I II FINISHED GRADE III -II AT SHRUBS I1- _ , -3" BACKFILL BASE FIRMLY COMPACTED. FILTER FABRIC ON TOP OF GRAVEL BED, WRAP 4" UP ALL SIDES. 2X ROOTBALL 48" AT 24" BOX 60" AT 30" BOX 72" AT 36" BOX 96" AT 48" BOX SPECIMEN TREE GUY WIRE PLANTING 1 " = 1' -0" 32 9343.26 -33 HABITAT MANAGEMENT AND LANDSCAPING PERMITS: 1. A HABITAT MANAGEMENT AND LANDSCAPING PERMIT IS REQUIRED FOR THE DEVELOPMENT OF THIS PROJECT. APPLICATION SHOULD NOT BE MADE UNTIL FINAL ADMINISTRATIVE APPROVAL HAS BEEN GRANTED. o. AN APPLICATION AND AN EXTRA COPY OF THE APPROVED FINAL APPLICATION PLAN MUST BE SUBMITTED TO THIS DEPARTMENT IN ORDER TO PROCESS THE PERMIT. b. ALL EXOTIC SPECIES, I.E., BRAZILIAN PEPPER (SCHINUS TEREBIN- THIFOLIUS), PUNK TREES (MELALEUCA QUINQUENERVIA), AND CHINESE TALLOW (SAPIUM SEBIFERUM) MUST BE REMOVED AS A CONDITION OF SITE DEVELOPMENT. WHERE NECESSARY DUE TO THEIR PROXIMITY TO PROTECTED PLANT MATERIAL, HAND REMOVAL WILL BE REQUIRED. SHOULD THIS REMOVAL BE TO A DEGREE THAT A POTENTIAL FOR EROSION IS CREATED, THE AREA MUST BE RESTABILIZED WITH SUITABLE MATERIAL. c. ONCE FINAL ADMINISTRATIVE APPROVAL (FAA) HAS BEEN GRANTED, A BARRICADE INSPECTION CAN BE SCHEDULED, WHEN THE BARRICADES HAVE BEEN APPROVED THE PERMIT CAN BE TYPED AND RELEASED. TREE PROTECTION AND PRESERVATION: TREE BARRICADES AND EROSION CONTROL MEASURE REQUIREMENTS: 1. TREE BARRICADES AND /OR SILT SCREENS OR HAYBALES SHALL BE REQUIRED ALONG THE EDGES OF VEGETATED AREAS TO BE PROTECTED PRIOR TO THE ISSUANCE OF HABITAT MANAGEMENT AND LANDSCAPE PERMITS. THE LOCATION FOR EROSION CONTROL MEASURES ARE SHOWN ON THE CONSTRUCTION DRAWINGS. 2. ALL DESIRABLE TREES MUST BE RETAINED WHEREVER POSSIBLE. IT WILL BE REQUIRED THAT PROPOSED IMPROVEMENTS (i.e. BUILDINGS, WALKWAYS, DRIVEWAYS, POND BANKS, DRAINAGE SYSTEMS, ETC.) BE ADJUSTED TO RETAIN DESIRABLE TREES. GRADE CHANGES MUST BE SENSITIVE TO TREES REMAINING. IN GENERAL, NO GRADE CHANGES SHOULD OCCUR WITHIN THE CANOPY DRIP LINE OF PINE TREES AND 2/3 THE CANOPY DRIP LINE OF HARDWOOD TREES TO BE SAVED. LANDSCAPING 1. EACH LANDSCAPING AND REPLANT TREE MUST BE PLANTED WITHIN A MINIMUM FIVE (5) FOOT BY TEN (10) FOOT OPEN SPACE PLANTER WITH SUITABLE GROUND COVER. LANDSCAPE TREES MUST BE PLANTED IN SAME VICINITY AS VEHICULAR USE AREAS IN ORDER TO BREAK THE MONOTONY OF UNBROKEN EXPANSES OF PAVING. TREES MUST NOT BE PLANTED WITHIN MAINTENANCE EASEMENTS. 2. THE USE OF XERISCAPE DESIGN MUST BE UTILIZED FOR THE REQUIRED LANDSCAPE DESIGN. THE DESIGN DEMONSTRATES THE USE OF A LOW VOLUME IRRIGATION SYSTEM, ORGANIC MULCHES, DROUGHT AND COLD TOLERANT PLANT MATERIAL, ZONING OF PLANT MATERIAL BY WATER REQUIREMENTS, SOIL AMENDMENTS (IF NECESSARY) AND THE PRACTICAL USE OF TURF. 3. NEW LANDSCAPING MUST BE PROTECTED FROM VEHICULAR MOVE - MENT BY WHEEL STOPS, OR CURBING. WHERE POSSIBLE, THE AREA BETWEEN THE BARRIER AND LANDSCAPE MATERIAL SHOULD REMAIN AS GREENSPACE. 4. LARGE TREE SPECIES PROPOSED FOR INSTALLATION MUST BE A MINIMUM OF 20 FEET AWAY FROM BUILDINGS, SIGNS, FENCES, LIGHT POLES, UTILITY LINES AND ANY OTHER OBSTRUCTIONS THAT MAY IMPAIR NATURAL GROWTH. 5. TREES PROPOSED FOR INSTALLATION MUST NOT BE IN CONFLICT WITH PROPOSED OR EXISTING UTILITY LINES OR STRUCTURES, EASE- MENTS OR OTHER AREAS WHICH MAY REQUIRE EXCAVATION IN THE EVENT OF SYSTEM FAILURE. THESE FEATURES SUCH AS THE WATER LINES MUST REMAIN OUTSIDE THE 5' X 10' PLANTER AREA. 6. SOILS WITHIN PLANTER BEDS MUST BE SUITABLE FOR PROPOSED PLANTED MATERIAL WITH REGARDS TO pH, SOIL TEXTURE, SOIL STRUCTURE, AND SEASONAL HIGH WATER TABLE, 7. ALL LANDSCAPE MATERIAL MUST BE FLORIDA GRADE #1 OR BETTER. 8. ALL REQUIRED TREES MUST BE A MINIMUM OF 10' HIGH, 2 1/2" CALIPER AT TIME OF PLANTING. 9. ALL HEDGES MUST BE 24" HIGH AT THE TIME OF PLANTING, PLANTED AT 36" ON CENTER, AND BE MAINTAINED AT A MINIMUM OF 3' IN HEIGHT, 10. WHERE LANDSCAPE OR REPLANT TREES ARE PROPOSED TO BE PLANTED IN THE PERIMETER BUFFER, THE BUFFER MUST BE A MINIMUM OF 5' WIDE. IRRIGATION NOTES 1. SHALLOW WELLS, OPEN SURFACE WATER BODIES, OR RECLAIMED WATER MUST BE USED AS A SOURCE OF IRRIGATION WATER. THE DIST- RIBUTION SYSTEM FOR IRRIGATION MUST NOT BE CONNECTED TO COUNTY OR MUNICIPAL WATER SOURCES, UNLESS IT CAN BE DEMON- STRATED THAT THESE SOURCES ARE NOT AVAILABLE. 2. IRRIGATION SYSTEMS MUST UTILIZE LOW VOLUME DESIGNS SUCH AS LOW TRAJECTORY HEADS OR SOAKER HOSES TO PROVIDE DIRECT AP- PLICATION AND LOW EVAPORATION. SYSTEMS THAT OVERSPRAY AREAS THAT DO NOT REQUIRE IRRIGATION, SUCH AS PAVED AREAS WILL NOT BE ACCEPTABLE. HIGH IRRIGATION NEED AREAS MUST NOT OVERSPRAY LOW NEED AREAS, 3. HIGH WATER DEMAND LANDSCAPE AREAS SUCH AS TURF MUST BE SERVED BY A SEPARATE IRRIGATION ZONE THAN LOW WATER NEED PLANTER BEDS, OR MULCHED AREAS WITH TREES. IN NO CASE, SHALL ANY PLANTED VEGETATION AREA BE MORE THAN 50' FROM A WATER SUPPLY HOSE BIBB. 4. AUTOMATIC IRRIGATION SYSTEMS MUST BE OPERATED BY AN IRRI- GATION SYSTEMS OPERATED BY AN IRRIGATION CONTROLLER CAPABLE OF DIFFERENTIATING BETWEEN THE SCHEDULES OF HIGH AND LOW WATER DEMAND AREAS. CONTROLLERS MUST HAVE MULTIPLE CYCLE START CAPACITY AND A FLEXIBLE CALENDAR PROGRAM ABLE TO BE SET TO COMPLY WITH LOCAL OR WATER MANAGEMENT DISTRICT IMPOSED RESTRICTIONS. 5. AUTOMATIC IRRIGATION SYSTEMS MUST BE EQUIPPED WITH RAIN SENSOR DEVICE OR SWITCH WHICH WILL OVERRIDE THE IRRIGATION CYCLE OF THE SPRINKLER SYSTEM WHEN ADEQUATE RAINFALL HAS OCCURRED. IRRIGATION NOTES (CONTINUED THE IRRIGATION CONTRACTOR SHALL PROVIDE AN UNDERGROUND IRRI- GATION SYSTEM TO COVER 1007 OF ALL ON SITE PLANTING AREA, THIS SYSTEM SHALL CONTAIN BUT NOT LIMITED TO THE FOLLOWING: 1. UNDERGROUND PIPING, SHALL BE PVC SCHEDULE 40 OR BETTER. 2. SEVEN (7) DAY PROGRAMMABLE TIME CLOCK TO ACTIVATE ZONES. 3. SPRINKLER HEADS COMPATIBLE WITH THE TYPE OF PLANTING. 4. ELECTRIC VALVES. 5. GAUGE 14 OF COPPER WIRE. 6. FIBERGLASS OR PLASTIC ZONE VALVE BOXES. WHERE PIPING IS UNDER DRIVEWAY AND CONCRETE WALKS, THE PIPES SHALL BE INSTALLED IN SCHEDULE 40 SLEEVES 18" BELOW GRADE. MATERIALS SUPPLIED SHALL BE EQUAL TO THOSE MANUFACTURED BY RAIN BIRD CO. OR APPROVED EQUAL. THE CONTRACTOR SHALL SUBMIT A SYSTEM LAY -OUT ALONG WITH CATALOG SHEETS OF ALL COMPONENTS IN THE SYSTEM TO THE OWNER FOR APPROVAL PRIOR TO INSTALLATION. THE ENTIRE SYSTEM SHALL BE GUARANTEED BY THE CONTRACTOR FOR ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE ARCHITECT/ ENGINEER. ANY AND ALL USE OF HOSE BIBBS IN ASSOCIATION WITH NON- POTABLE WATER SUPPLIES SHALL BE IN FULL COMPLIANCE WITH SBCCI STANDARD PLUMBING CODE, CHAPTER VI CRITERIA REFERENCE COLOR CODING OF ABOVE GRADE RISER PIPING AND LABEL /TAGGING OF OUTLETS AS NON- POTABLE WATER SUPPLY. ANY BUILDING TO BE DEMOLISHED IS SUBJECT TO NOTIFICATION TO THE AIR TOXICS SECTION OF THE COUNTY DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO ANY DEMOLITION OF BUILDINGS. XERISCAPING 1. ORGANIC MULCHES AND /OR DROUGHT TOLERANT GROUNDCOVERS WITHIN PROPOSED LANDSCAPE PLANTER BEDS. 2. DROUGHT AND COLD TOLERANT PLANT MATERIAL. 3. GROUPING OR ZONING PLANT MATERIAL BASE ON SIMILAR WATER REQUIREMENTS AND THE LOCATION OF PROPOSED IRRIGATION WATERING SYSTEMS. 4. THE USE OF SOIL TESTING TO IDENTIFY SOIL CONDITIONS NECES- SARY FOR THE CONTINUED SURVIVAL OF PROPOSED LANDSCAPING. 5. ORGANIC SOIL AMENDMENTS (SUCH AS TOP SOILS, MANURE'S, PEAT AND COMPOSTED MATERIALS) MIXED EXISTING SOILS WITHIN LANDS- CAPING PLANTER BEDS TO DEPTHS CONSISTENT WITH THE ROOT DEPTH OF PROPOSED PLANTED MATERIAL (USE ONLY IF EXISTING SOIL CONDITIONS WARRANT THESE AMENDMENTS). 6. THE PRESERVATION AND INCORPORATION OF EXISTING PLANT COMMUNITIES ON SITE INTO THE LANDSCAPE PLAN. 7. THE MINIMAL USE OF TURF GRASSES WHICH REQUIRE FREQUENT IRRIGATION. S. LOW- MAINTENANCE DESIGN. TREE & SHRUB PLANTING DETAILS 1. THE ROOT MASS FORM OF EACH TREE PROPOSED FOR INSTALLATION SHALL BE BALLED OR BURLAPPED, BARE ROOT TREES ARE NOT AC- CEPTABLE. ALL NONBIODEGRADABLE WRAPPINGS WILL BE REMOVED AND BURLAP WILL BE FOLDED DOWN TO ENHANCE WATER ABSORPTION. IF WIRE BASKETS ARE USED IN CONJUNCTION WITH BALLED AND BURLAPPED TREES. THE FIRST FEW ROWS OF EACH BASKET WILL BE REMOVED AT THE TIME OF INSTALLATION. 2. SUPPORTING APPARATUS SHALL BE REMOVED AFTER 1 COMPLETE GROWING SEASON. ALSO THE FLEXIBLE ATTACHMENTS SHALL BE USED WHERE SUPPORT WIRES ARE WRAPPED AROUND TREE TRUNKS /STEMS TO PREVENT CAMBIAL DAMAGE, 3. PLANTING HOLES ASSOCIATED WITH PROPOSED TREES MUST SLOPE (NOT COMPACTED) AND A MINIMUM OF 18 -24 INCHES WIDER THAN THE DIAMETER OF THE ROOT BALL. TREES SHALL BE INSTALLED SUCH THAT THE TOP OF THE ROOT MASS IS LEVEL WITH THE SURFACE OF THE PLANTING HOLE, TREES SHOULD BE INSTALLED 3 - 5 INCHES ABOVE GRADE ON SITES CONTAINING CLAY. A 2 - 3 INCH LAYER OF ORGANIC MULCH MUST ALSO BE PLACED OVER THE ENTIRE SURFACE OF EACH PLANTING HOLE. TO PREVENT FUNGAL INFECTION MULCH SHOULD BE PULLED BACK A FEW INCHES FROM THE BASE OF EACH TREE. 4. IF ON SITE SOIL CONDITIONS ARE SUCH THAT SOIL AMENDMENTS WILL BE NECESSARY, THE PLANTING MUST INCLUDE SOIL MIXTURE THROUGHOUT THE ENTIRE SECTION OF EACH PLANTER AREA TO A DEPTH CONSISTENT WITH THE ROOT DEVELOPMENT OF PROPOSED PLANT MATERIAL. 5. PLANTERS ADJACENT TO OR WITHIN VEHICULAR USE AREAS MUST BE CONSTRUCTED SUCH THAT LIMEROCK, ASPHALT, CONCRETE OR ANY OTHER OBSTRUCTIONS DO NOT EXTEND UNDER THE SURFACE INTO THE PLANTING AREAS. 6. THE PRACTICE OF TREE TRUNK WRAPPING AND THE APPLICATION OF PAINTS /TAR ONTO PRUNED TREE BRANCHES IS NOT RECOMMENDED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURAL, 7, PLEASE NOTE THAT THE USE OF FERTILIZERS DURING PLANT INSTALLATION IS NOT APPROVED. SCIENTIFIC EVIDENCE INDICATES THAT FERTILIZATION (SPECIFICALLY, THE APPLICATION OF NITROGEN) OF TREES /SHRUBS WITHIN THE FIRST GROWING SEASON INHIBITS ROOT GROWTH. THE LANDSCAPE BUFFER STRIP MUST BE CONSTRUCTED SUITABLE FOR PLANT MATERIAL INSTALLATION, Z 1 Q Mo 4v F v3 I 0 0%71 IL 94 Z%0 4 X0 W� o► C • pip 0 a I MU �i Z �v W H� Z o 1 W Z �/ • 0 M V 0► Z WN Z Z �M M JQ d at it Z c� J �W �3 id U,4 B #5936 o AM �0 ES Comm.: 2007 -P Drawn By: B.J.V. Checked By: H.G. ssue Date: 42407 Revisions: y J a W O CIO W H O Z W a a v h AL BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 - 521 -1684, FAX: 727 - 527 -7422, E -MAIL: RONSPLANSOTAMPABAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist FL -1235A C i Z W s' CM LU Z W Z 0 CM 0 W OrCu,,,,,, W W CJ H Uj CO3 Lu s_ m � W O °oJ L;Z MV ILI m2 "CINCH- TIE ", "GRO- STRAIT ", Z Z OR EQUAL FLEXIBLE RUBBER w o TREE TIES IN FIGURE EIGHT Uj FASHION. ATTACH TO STAKE l­- ¢ W/ TWO GALV. ROOFING NAILS. x 0 M - 2" LODGEPOLE PINE TREATED ' Q 1 1 TREE STAKES. SET STAKES APPROXIMATELY 120 DEGREES APART. oo r- 00 t tZ - FINISHED GRADE. �D L ROOTBALL I I I I 1= III =1 I, I r w w Z IIIIIIII�IIII- II �< x l O Un l m- AVOID PLACING STAKES Q Q THRU ROOTBALL. l . ... .... ll� STAKING DETAIL SET ROOTBALL CROWN 1 112" HIGHER THAN THE SURROUNDING FINISHED GRADE. SLOPE BACKFILL AWAY FROM ROOTBALL FOR POSITIVE DRAINAGE. PLANTING AT y PLANTING AT TURF AREAS. SHRUB AREAS. KEEP TURF CLEAR FOR A 18" KEEP MULCH 6" - 8" RADIUS CIRCLE AROUND THE FROM BASE OF TREE, TREE. MULCH WITH A 3 THICK LAYER OF SHREDDED BARK. MULCH WATER WELL AREA TO 3" DEPTH. RECESS TURF AREA 6" HIGH WATER 1 TO ALLOW FOR MULCH. WELL AT SHRUB AREAS. FINISHED GRADE AT LAWN. ( -II FINISHED GRADE AT SHRUBS. � x x -ICI =_ ICI- III -_ -= + ;mmm I:II�I =II II= III =I�I�I�I� -1 Q Ln N ° -� I I - -, ROOTBALL ;III - 0 ¢QQ ¢ O PLANT TABLETS AS I N N N N o NOTED OR SPEICIFIED, BACKFILL MIX, SEE 2X ROOTBALL NOTES AND SPECIFICATIONS. 32" AT 15 GALLON NATIVE SOIL MIX 48" AT 24" BOX FIRMLY COMPACTED. 60" AT 30" BOX 72" AT 36" BOX PLANT PIT DETAIL 2 TREE PLANTING MULTI -STAKE 32 9343.23 -03 TREE BARRICADE DETAIL I-/ U� 6' -8' 4' 1 " X 4" Horizontal Wood Members or Approved Substitute Barriers Placed at Protective Radius 2 /3rd's dripline for hardwoods (6'min) full dripline for pines (6'min) TREE BARRICADE DETAIL N.T.S. 10 GAUGE GALV. CABLE W/ TURNBUCKLE & CLEAR PLASTIC COATING 3 "x12" WOOD OR METAL FLAG, PAINTED WHITE. 45 DEG TYPICAL STAKING DETAIL PLANTING AT TURF AREAS. KEEP TURF CLEAR FOR A 18 ", RADIUS CIRCLE AROUND THE TREE. MULCH WITH A 3" THICK LAYER OF SHREDDED BARK. RECESS TURF AREA 1 " TO ALLOW FOR MULCH. FINISHED GRADE AT LAWN. xx x x'I_I =III + MMomom 11 =� J _ _ J d- O c0 00 ¢ N r7 n d M ~ l­-l�� O ¢¢¢¢ o Of ao �t o i- Nn d d 3" THICK GRAVEL BED V AS BASE OF PLANT PIT. FOUR 48" DIAMETER X 48" DEEP AUGERED HOLES FILLED WITH GRAVEL. PLANT PIT DETAIL ROOTBALL ROOTBALL as &o 2" x 2" Vertical Wood Stakes 12" LONG X 5/8" DIAMETER REINFORCED HOSE OVER WIRE ® TRUNK (TYP.) 1 " DIA. X 36" GALV. IRON PIPE ANCHOR W/ CAP ON TOP. ONE AT EACH TIE (3 REQ.) TOP OF PIPE TO BE 1" BELOW FINISHED GRADE FINISHED PLANTING AT SHRUB AREAS. SET ROOTBALL CROWN 1-1/2" HIGHER THAN THE SURROUNDING FINISHED GRADE. SLOPE BACKFILL AWAY FROM ROOTBALL FOR POSITIVE DRAINAGE. KEEP MULCH 6" - 8" FROM BASE OF TREE. MULCH WATER WELL AREA TO 3" DEPTH. 6" HIGH WATER WELL AT SHRUB AREAS. I -I I II FINISHED GRADE III -II AT SHRUBS I1- _ , -3" BACKFILL BASE FIRMLY COMPACTED. FILTER FABRIC ON TOP OF GRAVEL BED, WRAP 4" UP ALL SIDES. 2X ROOTBALL 48" AT 24" BOX 60" AT 30" BOX 72" AT 36" BOX 96" AT 48" BOX SPECIMEN TREE GUY WIRE PLANTING 1 " = 1' -0" 32 9343.26 -33 HABITAT MANAGEMENT AND LANDSCAPING PERMITS: 1. A HABITAT MANAGEMENT AND LANDSCAPING PERMIT IS REQUIRED FOR THE DEVELOPMENT OF THIS PROJECT. APPLICATION SHOULD NOT BE MADE UNTIL FINAL ADMINISTRATIVE APPROVAL HAS BEEN GRANTED. o. AN APPLICATION AND AN EXTRA COPY OF THE APPROVED FINAL APPLICATION PLAN MUST BE SUBMITTED TO THIS DEPARTMENT IN ORDER TO PROCESS THE PERMIT. b. ALL EXOTIC SPECIES, I.E., BRAZILIAN PEPPER (SCHINUS TEREBIN- THIFOLIUS), PUNK TREES (MELALEUCA QUINQUENERVIA), AND CHINESE TALLOW (SAPIUM SEBIFERUM) MUST BE REMOVED AS A CONDITION OF SITE DEVELOPMENT. WHERE NECESSARY DUE TO THEIR PROXIMITY TO PROTECTED PLANT MATERIAL, HAND REMOVAL WILL BE REQUIRED. SHOULD THIS REMOVAL BE TO A DEGREE THAT A POTENTIAL FOR EROSION IS CREATED, THE AREA MUST BE RESTABILIZED WITH SUITABLE MATERIAL. c. ONCE FINAL ADMINISTRATIVE APPROVAL (FAA) HAS BEEN GRANTED, A BARRICADE INSPECTION CAN BE SCHEDULED, WHEN THE BARRICADES HAVE BEEN APPROVED THE PERMIT CAN BE TYPED AND RELEASED. TREE PROTECTION AND PRESERVATION: TREE BARRICADES AND EROSION CONTROL MEASURE REQUIREMENTS: 1. TREE BARRICADES AND /OR SILT SCREENS OR HAYBALES SHALL BE REQUIRED ALONG THE EDGES OF VEGETATED AREAS TO BE PROTECTED PRIOR TO THE ISSUANCE OF HABITAT MANAGEMENT AND LANDSCAPE PERMITS. THE LOCATION FOR EROSION CONTROL MEASURES ARE SHOWN ON THE CONSTRUCTION DRAWINGS. 2. ALL DESIRABLE TREES MUST BE RETAINED WHEREVER POSSIBLE. IT WILL BE REQUIRED THAT PROPOSED IMPROVEMENTS (i.e. BUILDINGS, WALKWAYS, DRIVEWAYS, POND BANKS, DRAINAGE SYSTEMS, ETC.) BE ADJUSTED TO RETAIN DESIRABLE TREES. GRADE CHANGES MUST BE SENSITIVE TO TREES REMAINING. IN GENERAL, NO GRADE CHANGES SHOULD OCCUR WITHIN THE CANOPY DRIP LINE OF PINE TREES AND 2/3 THE CANOPY DRIP LINE OF HARDWOOD TREES TO BE SAVED. LANDSCAPING 1. EACH LANDSCAPING AND REPLANT TREE MUST BE PLANTED WITHIN A MINIMUM FIVE (5) FOOT BY TEN (10) FOOT OPEN SPACE PLANTER WITH SUITABLE GROUND COVER. LANDSCAPE TREES MUST BE PLANTED IN SAME VICINITY AS VEHICULAR USE AREAS IN ORDER TO BREAK THE MONOTONY OF UNBROKEN EXPANSES OF PAVING. TREES MUST NOT BE PLANTED WITHIN MAINTENANCE EASEMENTS. 2. THE USE OF XERISCAPE DESIGN MUST BE UTILIZED FOR THE REQUIRED LANDSCAPE DESIGN. THE DESIGN DEMONSTRATES THE USE OF A LOW VOLUME IRRIGATION SYSTEM, ORGANIC MULCHES, DROUGHT AND COLD TOLERANT PLANT MATERIAL, ZONING OF PLANT MATERIAL BY WATER REQUIREMENTS, SOIL AMENDMENTS (IF NECESSARY) AND THE PRACTICAL USE OF TURF. 3. NEW LANDSCAPING MUST BE PROTECTED FROM VEHICULAR MOVE - MENT BY WHEEL STOPS, OR CURBING. WHERE POSSIBLE, THE AREA BETWEEN THE BARRIER AND LANDSCAPE MATERIAL SHOULD REMAIN AS GREENSPACE. 4. LARGE TREE SPECIES PROPOSED FOR INSTALLATION MUST BE A MINIMUM OF 20 FEET AWAY FROM BUILDINGS, SIGNS, FENCES, LIGHT POLES, UTILITY LINES AND ANY OTHER OBSTRUCTIONS THAT MAY IMPAIR NATURAL GROWTH. 5. TREES PROPOSED FOR INSTALLATION MUST NOT BE IN CONFLICT WITH PROPOSED OR EXISTING UTILITY LINES OR STRUCTURES, EASE- MENTS OR OTHER AREAS WHICH MAY REQUIRE EXCAVATION IN THE EVENT OF SYSTEM FAILURE. THESE FEATURES SUCH AS THE WATER LINES MUST REMAIN OUTSIDE THE 5' X 10' PLANTER AREA. 6. SOILS WITHIN PLANTER BEDS MUST BE SUITABLE FOR PROPOSED PLANTED MATERIAL WITH REGARDS TO pH, SOIL TEXTURE, SOIL STRUCTURE, AND SEASONAL HIGH WATER TABLE, 7. ALL LANDSCAPE MATERIAL MUST BE FLORIDA GRADE #1 OR BETTER. 8. ALL REQUIRED TREES MUST BE A MINIMUM OF 10' HIGH, 2 1/2" CALIPER AT TIME OF PLANTING. 9. ALL HEDGES MUST BE 24" HIGH AT THE TIME OF PLANTING, PLANTED AT 36" ON CENTER, AND BE MAINTAINED AT A MINIMUM OF 3' IN HEIGHT, 10. WHERE LANDSCAPE OR REPLANT TREES ARE PROPOSED TO BE PLANTED IN THE PERIMETER BUFFER, THE BUFFER MUST BE A MINIMUM OF 5' WIDE. IRRIGATION NOTES 1. SHALLOW WELLS, OPEN SURFACE WATER BODIES, OR RECLAIMED WATER MUST BE USED AS A SOURCE OF IRRIGATION WATER. THE DIST- RIBUTION SYSTEM FOR IRRIGATION MUST NOT BE CONNECTED TO COUNTY OR MUNICIPAL WATER SOURCES, UNLESS IT CAN BE DEMON- STRATED THAT THESE SOURCES ARE NOT AVAILABLE. 2. IRRIGATION SYSTEMS MUST UTILIZE LOW VOLUME DESIGNS SUCH AS LOW TRAJECTORY HEADS OR SOAKER HOSES TO PROVIDE DIRECT AP- PLICATION AND LOW EVAPORATION. SYSTEMS THAT OVERSPRAY AREAS THAT DO NOT REQUIRE IRRIGATION, SUCH AS PAVED AREAS WILL NOT BE ACCEPTABLE. HIGH IRRIGATION NEED AREAS MUST NOT OVERSPRAY LOW NEED AREAS, 3. HIGH WATER DEMAND LANDSCAPE AREAS SUCH AS TURF MUST BE SERVED BY A SEPARATE IRRIGATION ZONE THAN LOW WATER NEED PLANTER BEDS, OR MULCHED AREAS WITH TREES. IN NO CASE, SHALL ANY PLANTED VEGETATION AREA BE MORE THAN 50' FROM A WATER SUPPLY HOSE BIBB. 4. AUTOMATIC IRRIGATION SYSTEMS MUST BE OPERATED BY AN IRRI- GATION SYSTEMS OPERATED BY AN IRRIGATION CONTROLLER CAPABLE OF DIFFERENTIATING BETWEEN THE SCHEDULES OF HIGH AND LOW WATER DEMAND AREAS. CONTROLLERS MUST HAVE MULTIPLE CYCLE START CAPACITY AND A FLEXIBLE CALENDAR PROGRAM ABLE TO BE SET TO COMPLY WITH LOCAL OR WATER MANAGEMENT DISTRICT IMPOSED RESTRICTIONS. 5. AUTOMATIC IRRIGATION SYSTEMS MUST BE EQUIPPED WITH RAIN SENSOR DEVICE OR SWITCH WHICH WILL OVERRIDE THE IRRIGATION CYCLE OF THE SPRINKLER SYSTEM WHEN ADEQUATE RAINFALL HAS OCCURRED. IRRIGATION NOTES (CONTINUED THE IRRIGATION CONTRACTOR SHALL PROVIDE AN UNDERGROUND IRRI- GATION SYSTEM TO COVER 1007 OF ALL ON SITE PLANTING AREA, THIS SYSTEM SHALL CONTAIN BUT NOT LIMITED TO THE FOLLOWING: 1. UNDERGROUND PIPING, SHALL BE PVC SCHEDULE 40 OR BETTER. 2. SEVEN (7) DAY PROGRAMMABLE TIME CLOCK TO ACTIVATE ZONES. 3. SPRINKLER HEADS COMPATIBLE WITH THE TYPE OF PLANTING. 4. ELECTRIC VALVES. 5. GAUGE 14 OF COPPER WIRE. 6. FIBERGLASS OR PLASTIC ZONE VALVE BOXES. WHERE PIPING IS UNDER DRIVEWAY AND CONCRETE WALKS, THE PIPES SHALL BE INSTALLED IN SCHEDULE 40 SLEEVES 18" BELOW GRADE. MATERIALS SUPPLIED SHALL BE EQUAL TO THOSE MANUFACTURED BY RAIN BIRD CO. OR APPROVED EQUAL. THE CONTRACTOR SHALL SUBMIT A SYSTEM LAY -OUT ALONG WITH CATALOG SHEETS OF ALL COMPONENTS IN THE SYSTEM TO THE OWNER FOR APPROVAL PRIOR TO INSTALLATION. THE ENTIRE SYSTEM SHALL BE GUARANTEED BY THE CONTRACTOR FOR ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE ARCHITECT/ ENGINEER. ANY AND ALL USE OF HOSE BIBBS IN ASSOCIATION WITH NON- POTABLE WATER SUPPLIES SHALL BE IN FULL COMPLIANCE WITH SBCCI STANDARD PLUMBING CODE, CHAPTER VI CRITERIA REFERENCE COLOR CODING OF ABOVE GRADE RISER PIPING AND LABEL /TAGGING OF OUTLETS AS NON- POTABLE WATER SUPPLY. ANY BUILDING TO BE DEMOLISHED IS SUBJECT TO NOTIFICATION TO THE AIR TOXICS SECTION OF THE COUNTY DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO ANY DEMOLITION OF BUILDINGS. XERISCAPING 1. ORGANIC MULCHES AND /OR DROUGHT TOLERANT GROUNDCOVERS WITHIN PROPOSED LANDSCAPE PLANTER BEDS. 2. DROUGHT AND COLD TOLERANT PLANT MATERIAL. 3. GROUPING OR ZONING PLANT MATERIAL BASE ON SIMILAR WATER REQUIREMENTS AND THE LOCATION OF PROPOSED IRRIGATION WATERING SYSTEMS. 4. THE USE OF SOIL TESTING TO IDENTIFY SOIL CONDITIONS NECES- SARY FOR THE CONTINUED SURVIVAL OF PROPOSED LANDSCAPING. 5. ORGANIC SOIL AMENDMENTS (SUCH AS TOP SOILS, MANURE'S, PEAT AND COMPOSTED MATERIALS) MIXED EXISTING SOILS WITHIN LANDS- CAPING PLANTER BEDS TO DEPTHS CONSISTENT WITH THE ROOT DEPTH OF PROPOSED PLANTED MATERIAL (USE ONLY IF EXISTING SOIL CONDITIONS WARRANT THESE AMENDMENTS). 6. THE PRESERVATION AND INCORPORATION OF EXISTING PLANT COMMUNITIES ON SITE INTO THE LANDSCAPE PLAN. 7. THE MINIMAL USE OF TURF GRASSES WHICH REQUIRE FREQUENT IRRIGATION. S. LOW- MAINTENANCE DESIGN. TREE & SHRUB PLANTING DETAILS 1. THE ROOT MASS FORM OF EACH TREE PROPOSED FOR INSTALLATION SHALL BE BALLED OR BURLAPPED, BARE ROOT TREES ARE NOT AC- CEPTABLE. ALL NONBIODEGRADABLE WRAPPINGS WILL BE REMOVED AND BURLAP WILL BE FOLDED DOWN TO ENHANCE WATER ABSORPTION. IF WIRE BASKETS ARE USED IN CONJUNCTION WITH BALLED AND BURLAPPED TREES. THE FIRST FEW ROWS OF EACH BASKET WILL BE REMOVED AT THE TIME OF INSTALLATION. 2. SUPPORTING APPARATUS SHALL BE REMOVED AFTER 1 COMPLETE GROWING SEASON. ALSO THE FLEXIBLE ATTACHMENTS SHALL BE USED WHERE SUPPORT WIRES ARE WRAPPED AROUND TREE TRUNKS /STEMS TO PREVENT CAMBIAL DAMAGE, 3. PLANTING HOLES ASSOCIATED WITH PROPOSED TREES MUST SLOPE (NOT COMPACTED) AND A MINIMUM OF 18 -24 INCHES WIDER THAN THE DIAMETER OF THE ROOT BALL. TREES SHALL BE INSTALLED SUCH THAT THE TOP OF THE ROOT MASS IS LEVEL WITH THE SURFACE OF THE PLANTING HOLE, TREES SHOULD BE INSTALLED 3 - 5 INCHES ABOVE GRADE ON SITES CONTAINING CLAY. A 2 - 3 INCH LAYER OF ORGANIC MULCH MUST ALSO BE PLACED OVER THE ENTIRE SURFACE OF EACH PLANTING HOLE. TO PREVENT FUNGAL INFECTION MULCH SHOULD BE PULLED BACK A FEW INCHES FROM THE BASE OF EACH TREE. 4. IF ON SITE SOIL CONDITIONS ARE SUCH THAT SOIL AMENDMENTS WILL BE NECESSARY, THE PLANTING MUST INCLUDE SOIL MIXTURE THROUGHOUT THE ENTIRE SECTION OF EACH PLANTER AREA TO A DEPTH CONSISTENT WITH THE ROOT DEVELOPMENT OF PROPOSED PLANT MATERIAL. 5. PLANTERS ADJACENT TO OR WITHIN VEHICULAR USE AREAS MUST BE CONSTRUCTED SUCH THAT LIMEROCK, ASPHALT, CONCRETE OR ANY OTHER OBSTRUCTIONS DO NOT EXTEND UNDER THE SURFACE INTO THE PLANTING AREAS. 6. THE PRACTICE OF TREE TRUNK WRAPPING AND THE APPLICATION OF PAINTS /TAR ONTO PRUNED TREE BRANCHES IS NOT RECOMMENDED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURAL, 7, PLEASE NOTE THAT THE USE OF FERTILIZERS DURING PLANT INSTALLATION IS NOT APPROVED. SCIENTIFIC EVIDENCE INDICATES THAT FERTILIZATION (SPECIFICALLY, THE APPLICATION OF NITROGEN) OF TREES /SHRUBS WITHIN THE FIRST GROWING SEASON INHIBITS ROOT GROWTH. THE LANDSCAPE BUFFER STRIP MUST BE CONSTRUCTED SUITABLE FOR PLANT MATERIAL INSTALLATION, Z 1 Q Mo 4v F v3 I 0 0%71 IL 94 Z%0 4 X0 W� o► C • pip 0 a I MU �i Z �v W H� Z o 1 W Z �/ • 0 M V 0► Z WN Z Z �M M JQ d at it Z c� J �W �3 id U,4 B #5936 o AM �0 ES Comm.: 2007 -P Drawn By: B.J.V. Checked By: H.G. ssue Date: 42407 Revisions: y J a W O CIO W H O Z W a a v h AL BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 - 521 -1684, FAX: 727 - 527 -7422, E -MAIL: RONSPLANSOTAMPABAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist FL -1235A C i Z W s' CM LU Z W Z 0 CM 0 W OrCu,,,,,, W W CJ H Uj CO3 Lu s_ m � W O °oJ L;Z MV ILI m2 PLANT PIT DETAIL 2 TREE PLANTING MULTI -STAKE 32 9343.23 -03 TREE BARRICADE DETAIL I-/ U� 6' -8' 4' 1 " X 4" Horizontal Wood Members or Approved Substitute Barriers Placed at Protective Radius 2 /3rd's dripline for hardwoods (6'min) full dripline for pines (6'min) TREE BARRICADE DETAIL N.T.S. 10 GAUGE GALV. CABLE W/ TURNBUCKLE & CLEAR PLASTIC COATING 3 "x12" WOOD OR METAL FLAG, PAINTED WHITE. 45 DEG TYPICAL STAKING DETAIL PLANTING AT TURF AREAS. KEEP TURF CLEAR FOR A 18 ", RADIUS CIRCLE AROUND THE TREE. MULCH WITH A 3" THICK LAYER OF SHREDDED BARK. RECESS TURF AREA 1 " TO ALLOW FOR MULCH. FINISHED GRADE AT LAWN. xx x x'I_I =III + MMomom 11 =� J _ _ J d- O c0 00 ¢ N r7 n d M ~ l­-l�� O ¢¢¢¢ o Of ao �t o i- Nn d d 3" THICK GRAVEL BED V AS BASE OF PLANT PIT. FOUR 48" DIAMETER X 48" DEEP AUGERED HOLES FILLED WITH GRAVEL. PLANT PIT DETAIL ROOTBALL ROOTBALL as &o 2" x 2" Vertical Wood Stakes 12" LONG X 5/8" DIAMETER REINFORCED HOSE OVER WIRE ® TRUNK (TYP.) 1 " DIA. X 36" GALV. IRON PIPE ANCHOR W/ CAP ON TOP. ONE AT EACH TIE (3 REQ.) TOP OF PIPE TO BE 1" BELOW FINISHED GRADE FINISHED PLANTING AT SHRUB AREAS. SET ROOTBALL CROWN 1-1/2" HIGHER THAN THE SURROUNDING FINISHED GRADE. SLOPE BACKFILL AWAY FROM ROOTBALL FOR POSITIVE DRAINAGE. KEEP MULCH 6" - 8" FROM BASE OF TREE. MULCH WATER WELL AREA TO 3" DEPTH. 6" HIGH WATER WELL AT SHRUB AREAS. I -I I II FINISHED GRADE III -II AT SHRUBS I1- _ , -3" BACKFILL BASE FIRMLY COMPACTED. FILTER FABRIC ON TOP OF GRAVEL BED, WRAP 4" UP ALL SIDES. 2X ROOTBALL 48" AT 24" BOX 60" AT 30" BOX 72" AT 36" BOX 96" AT 48" BOX SPECIMEN TREE GUY WIRE PLANTING 1 " = 1' -0" 32 9343.26 -33 HABITAT MANAGEMENT AND LANDSCAPING PERMITS: 1. A HABITAT MANAGEMENT AND LANDSCAPING PERMIT IS REQUIRED FOR THE DEVELOPMENT OF THIS PROJECT. APPLICATION SHOULD NOT BE MADE UNTIL FINAL ADMINISTRATIVE APPROVAL HAS BEEN GRANTED. o. AN APPLICATION AND AN EXTRA COPY OF THE APPROVED FINAL APPLICATION PLAN MUST BE SUBMITTED TO THIS DEPARTMENT IN ORDER TO PROCESS THE PERMIT. b. ALL EXOTIC SPECIES, I.E., BRAZILIAN PEPPER (SCHINUS TEREBIN- THIFOLIUS), PUNK TREES (MELALEUCA QUINQUENERVIA), AND CHINESE TALLOW (SAPIUM SEBIFERUM) MUST BE REMOVED AS A CONDITION OF SITE DEVELOPMENT. WHERE NECESSARY DUE TO THEIR PROXIMITY TO PROTECTED PLANT MATERIAL, HAND REMOVAL WILL BE REQUIRED. SHOULD THIS REMOVAL BE TO A DEGREE THAT A POTENTIAL FOR EROSION IS CREATED, THE AREA MUST BE RESTABILIZED WITH SUITABLE MATERIAL. c. ONCE FINAL ADMINISTRATIVE APPROVAL (FAA) HAS BEEN GRANTED, A BARRICADE INSPECTION CAN BE SCHEDULED, WHEN THE BARRICADES HAVE BEEN APPROVED THE PERMIT CAN BE TYPED AND RELEASED. TREE PROTECTION AND PRESERVATION: TREE BARRICADES AND EROSION CONTROL MEASURE REQUIREMENTS: 1. TREE BARRICADES AND /OR SILT SCREENS OR HAYBALES SHALL BE REQUIRED ALONG THE EDGES OF VEGETATED AREAS TO BE PROTECTED PRIOR TO THE ISSUANCE OF HABITAT MANAGEMENT AND LANDSCAPE PERMITS. THE LOCATION FOR EROSION CONTROL MEASURES ARE SHOWN ON THE CONSTRUCTION DRAWINGS. 2. ALL DESIRABLE TREES MUST BE RETAINED WHEREVER POSSIBLE. IT WILL BE REQUIRED THAT PROPOSED IMPROVEMENTS (i.e. BUILDINGS, WALKWAYS, DRIVEWAYS, POND BANKS, DRAINAGE SYSTEMS, ETC.) BE ADJUSTED TO RETAIN DESIRABLE TREES. GRADE CHANGES MUST BE SENSITIVE TO TREES REMAINING. IN GENERAL, NO GRADE CHANGES SHOULD OCCUR WITHIN THE CANOPY DRIP LINE OF PINE TREES AND 2/3 THE CANOPY DRIP LINE OF HARDWOOD TREES TO BE SAVED. LANDSCAPING 1. EACH LANDSCAPING AND REPLANT TREE MUST BE PLANTED WITHIN A MINIMUM FIVE (5) FOOT BY TEN (10) FOOT OPEN SPACE PLANTER WITH SUITABLE GROUND COVER. LANDSCAPE TREES MUST BE PLANTED IN SAME VICINITY AS VEHICULAR USE AREAS IN ORDER TO BREAK THE MONOTONY OF UNBROKEN EXPANSES OF PAVING. TREES MUST NOT BE PLANTED WITHIN MAINTENANCE EASEMENTS. 2. THE USE OF XERISCAPE DESIGN MUST BE UTILIZED FOR THE REQUIRED LANDSCAPE DESIGN. THE DESIGN DEMONSTRATES THE USE OF A LOW VOLUME IRRIGATION SYSTEM, ORGANIC MULCHES, DROUGHT AND COLD TOLERANT PLANT MATERIAL, ZONING OF PLANT MATERIAL BY WATER REQUIREMENTS, SOIL AMENDMENTS (IF NECESSARY) AND THE PRACTICAL USE OF TURF. 3. NEW LANDSCAPING MUST BE PROTECTED FROM VEHICULAR MOVE - MENT BY WHEEL STOPS, OR CURBING. WHERE POSSIBLE, THE AREA BETWEEN THE BARRIER AND LANDSCAPE MATERIAL SHOULD REMAIN AS GREENSPACE. 4. LARGE TREE SPECIES PROPOSED FOR INSTALLATION MUST BE A MINIMUM OF 20 FEET AWAY FROM BUILDINGS, SIGNS, FENCES, LIGHT POLES, UTILITY LINES AND ANY OTHER OBSTRUCTIONS THAT MAY IMPAIR NATURAL GROWTH. 5. TREES PROPOSED FOR INSTALLATION MUST NOT BE IN CONFLICT WITH PROPOSED OR EXISTING UTILITY LINES OR STRUCTURES, EASE- MENTS OR OTHER AREAS WHICH MAY REQUIRE EXCAVATION IN THE EVENT OF SYSTEM FAILURE. THESE FEATURES SUCH AS THE WATER LINES MUST REMAIN OUTSIDE THE 5' X 10' PLANTER AREA. 6. SOILS WITHIN PLANTER BEDS MUST BE SUITABLE FOR PROPOSED PLANTED MATERIAL WITH REGARDS TO pH, SOIL TEXTURE, SOIL STRUCTURE, AND SEASONAL HIGH WATER TABLE, 7. ALL LANDSCAPE MATERIAL MUST BE FLORIDA GRADE #1 OR BETTER. 8. ALL REQUIRED TREES MUST BE A MINIMUM OF 10' HIGH, 2 1/2" CALIPER AT TIME OF PLANTING. 9. ALL HEDGES MUST BE 24" HIGH AT THE TIME OF PLANTING, PLANTED AT 36" ON CENTER, AND BE MAINTAINED AT A MINIMUM OF 3' IN HEIGHT, 10. WHERE LANDSCAPE OR REPLANT TREES ARE PROPOSED TO BE PLANTED IN THE PERIMETER BUFFER, THE BUFFER MUST BE A MINIMUM OF 5' WIDE. IRRIGATION NOTES 1. SHALLOW WELLS, OPEN SURFACE WATER BODIES, OR RECLAIMED WATER MUST BE USED AS A SOURCE OF IRRIGATION WATER. THE DIST- RIBUTION SYSTEM FOR IRRIGATION MUST NOT BE CONNECTED TO COUNTY OR MUNICIPAL WATER SOURCES, UNLESS IT CAN BE DEMON- STRATED THAT THESE SOURCES ARE NOT AVAILABLE. 2. IRRIGATION SYSTEMS MUST UTILIZE LOW VOLUME DESIGNS SUCH AS LOW TRAJECTORY HEADS OR SOAKER HOSES TO PROVIDE DIRECT AP- PLICATION AND LOW EVAPORATION. SYSTEMS THAT OVERSPRAY AREAS THAT DO NOT REQUIRE IRRIGATION, SUCH AS PAVED AREAS WILL NOT BE ACCEPTABLE. HIGH IRRIGATION NEED AREAS MUST NOT OVERSPRAY LOW NEED AREAS, 3. HIGH WATER DEMAND LANDSCAPE AREAS SUCH AS TURF MUST BE SERVED BY A SEPARATE IRRIGATION ZONE THAN LOW WATER NEED PLANTER BEDS, OR MULCHED AREAS WITH TREES. IN NO CASE, SHALL ANY PLANTED VEGETATION AREA BE MORE THAN 50' FROM A WATER SUPPLY HOSE BIBB. 4. AUTOMATIC IRRIGATION SYSTEMS MUST BE OPERATED BY AN IRRI- GATION SYSTEMS OPERATED BY AN IRRIGATION CONTROLLER CAPABLE OF DIFFERENTIATING BETWEEN THE SCHEDULES OF HIGH AND LOW WATER DEMAND AREAS. CONTROLLERS MUST HAVE MULTIPLE CYCLE START CAPACITY AND A FLEXIBLE CALENDAR PROGRAM ABLE TO BE SET TO COMPLY WITH LOCAL OR WATER MANAGEMENT DISTRICT IMPOSED RESTRICTIONS. 5. AUTOMATIC IRRIGATION SYSTEMS MUST BE EQUIPPED WITH RAIN SENSOR DEVICE OR SWITCH WHICH WILL OVERRIDE THE IRRIGATION CYCLE OF THE SPRINKLER SYSTEM WHEN ADEQUATE RAINFALL HAS OCCURRED. IRRIGATION NOTES (CONTINUED THE IRRIGATION CONTRACTOR SHALL PROVIDE AN UNDERGROUND IRRI- GATION SYSTEM TO COVER 1007 OF ALL ON SITE PLANTING AREA, THIS SYSTEM SHALL CONTAIN BUT NOT LIMITED TO THE FOLLOWING: 1. UNDERGROUND PIPING, SHALL BE PVC SCHEDULE 40 OR BETTER. 2. SEVEN (7) DAY PROGRAMMABLE TIME CLOCK TO ACTIVATE ZONES. 3. SPRINKLER HEADS COMPATIBLE WITH THE TYPE OF PLANTING. 4. ELECTRIC VALVES. 5. GAUGE 14 OF COPPER WIRE. 6. FIBERGLASS OR PLASTIC ZONE VALVE BOXES. WHERE PIPING IS UNDER DRIVEWAY AND CONCRETE WALKS, THE PIPES SHALL BE INSTALLED IN SCHEDULE 40 SLEEVES 18" BELOW GRADE. MATERIALS SUPPLIED SHALL BE EQUAL TO THOSE MANUFACTURED BY RAIN BIRD CO. OR APPROVED EQUAL. THE CONTRACTOR SHALL SUBMIT A SYSTEM LAY -OUT ALONG WITH CATALOG SHEETS OF ALL COMPONENTS IN THE SYSTEM TO THE OWNER FOR APPROVAL PRIOR TO INSTALLATION. THE ENTIRE SYSTEM SHALL BE GUARANTEED BY THE CONTRACTOR FOR ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE ARCHITECT/ ENGINEER. ANY AND ALL USE OF HOSE BIBBS IN ASSOCIATION WITH NON- POTABLE WATER SUPPLIES SHALL BE IN FULL COMPLIANCE WITH SBCCI STANDARD PLUMBING CODE, CHAPTER VI CRITERIA REFERENCE COLOR CODING OF ABOVE GRADE RISER PIPING AND LABEL /TAGGING OF OUTLETS AS NON- POTABLE WATER SUPPLY. ANY BUILDING TO BE DEMOLISHED IS SUBJECT TO NOTIFICATION TO THE AIR TOXICS SECTION OF THE COUNTY DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO ANY DEMOLITION OF BUILDINGS. XERISCAPING 1. ORGANIC MULCHES AND /OR DROUGHT TOLERANT GROUNDCOVERS WITHIN PROPOSED LANDSCAPE PLANTER BEDS. 2. DROUGHT AND COLD TOLERANT PLANT MATERIAL. 3. GROUPING OR ZONING PLANT MATERIAL BASE ON SIMILAR WATER REQUIREMENTS AND THE LOCATION OF PROPOSED IRRIGATION WATERING SYSTEMS. 4. THE USE OF SOIL TESTING TO IDENTIFY SOIL CONDITIONS NECES- SARY FOR THE CONTINUED SURVIVAL OF PROPOSED LANDSCAPING. 5. ORGANIC SOIL AMENDMENTS (SUCH AS TOP SOILS, MANURE'S, PEAT AND COMPOSTED MATERIALS) MIXED EXISTING SOILS WITHIN LANDS- CAPING PLANTER BEDS TO DEPTHS CONSISTENT WITH THE ROOT DEPTH OF PROPOSED PLANTED MATERIAL (USE ONLY IF EXISTING SOIL CONDITIONS WARRANT THESE AMENDMENTS). 6. THE PRESERVATION AND INCORPORATION OF EXISTING PLANT COMMUNITIES ON SITE INTO THE LANDSCAPE PLAN. 7. THE MINIMAL USE OF TURF GRASSES WHICH REQUIRE FREQUENT IRRIGATION. S. LOW- MAINTENANCE DESIGN. TREE & SHRUB PLANTING DETAILS 1. THE ROOT MASS FORM OF EACH TREE PROPOSED FOR INSTALLATION SHALL BE BALLED OR BURLAPPED, BARE ROOT TREES ARE NOT AC- CEPTABLE. ALL NONBIODEGRADABLE WRAPPINGS WILL BE REMOVED AND BURLAP WILL BE FOLDED DOWN TO ENHANCE WATER ABSORPTION. IF WIRE BASKETS ARE USED IN CONJUNCTION WITH BALLED AND BURLAPPED TREES. THE FIRST FEW ROWS OF EACH BASKET WILL BE REMOVED AT THE TIME OF INSTALLATION. 2. SUPPORTING APPARATUS SHALL BE REMOVED AFTER 1 COMPLETE GROWING SEASON. ALSO THE FLEXIBLE ATTACHMENTS SHALL BE USED WHERE SUPPORT WIRES ARE WRAPPED AROUND TREE TRUNKS /STEMS TO PREVENT CAMBIAL DAMAGE, 3. PLANTING HOLES ASSOCIATED WITH PROPOSED TREES MUST SLOPE (NOT COMPACTED) AND A MINIMUM OF 18 -24 INCHES WIDER THAN THE DIAMETER OF THE ROOT BALL. TREES SHALL BE INSTALLED SUCH THAT THE TOP OF THE ROOT MASS IS LEVEL WITH THE SURFACE OF THE PLANTING HOLE, TREES SHOULD BE INSTALLED 3 - 5 INCHES ABOVE GRADE ON SITES CONTAINING CLAY. A 2 - 3 INCH LAYER OF ORGANIC MULCH MUST ALSO BE PLACED OVER THE ENTIRE SURFACE OF EACH PLANTING HOLE. TO PREVENT FUNGAL INFECTION MULCH SHOULD BE PULLED BACK A FEW INCHES FROM THE BASE OF EACH TREE. 4. IF ON SITE SOIL CONDITIONS ARE SUCH THAT SOIL AMENDMENTS WILL BE NECESSARY, THE PLANTING MUST INCLUDE SOIL MIXTURE THROUGHOUT THE ENTIRE SECTION OF EACH PLANTER AREA TO A DEPTH CONSISTENT WITH THE ROOT DEVELOPMENT OF PROPOSED PLANT MATERIAL. 5. PLANTERS ADJACENT TO OR WITHIN VEHICULAR USE AREAS MUST BE CONSTRUCTED SUCH THAT LIMEROCK, ASPHALT, CONCRETE OR ANY OTHER OBSTRUCTIONS DO NOT EXTEND UNDER THE SURFACE INTO THE PLANTING AREAS. 6. THE PRACTICE OF TREE TRUNK WRAPPING AND THE APPLICATION OF PAINTS /TAR ONTO PRUNED TREE BRANCHES IS NOT RECOMMENDED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURAL, 7, PLEASE NOTE THAT THE USE OF FERTILIZERS DURING PLANT INSTALLATION IS NOT APPROVED. SCIENTIFIC EVIDENCE INDICATES THAT FERTILIZATION (SPECIFICALLY, THE APPLICATION OF NITROGEN) OF TREES /SHRUBS WITHIN THE FIRST GROWING SEASON INHIBITS ROOT GROWTH. THE LANDSCAPE BUFFER STRIP MUST BE CONSTRUCTED SUITABLE FOR PLANT MATERIAL INSTALLATION, Z 1 Q Mo 4v F v3 I 0 0%71 IL 94 Z%0 4 X0 W� o► C • pip 0 a I MU �i Z �v W H� Z o 1 W Z �/ • 0 M V 0► Z WN Z Z �M M JQ d at it Z c� J �W �3 id U,4 B #5936 o AM �0 ES Comm.: 2007 -P Drawn By: B.J.V. Checked By: H.G. ssue Date: 42407 Revisions: y J a W O CIO W H O Z W a a v h AL BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 - 521 -1684, FAX: 727 - 527 -7422, E -MAIL: RONSPLANSOTAMPABAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist FL -1235A C i Z W s' CM LU Z W Z 0 CM 0 W OrCu,,,,,, W W CJ H Uj CO3 Lu s_ m � W O °oJ L;Z MV ILI m2 3" THICK GRAVEL BED V AS BASE OF PLANT PIT. FOUR 48" DIAMETER X 48" DEEP AUGERED HOLES FILLED WITH GRAVEL. PLANT PIT DETAIL ROOTBALL ROOTBALL as &o 2" x 2" Vertical Wood Stakes 12" LONG X 5/8" DIAMETER REINFORCED HOSE OVER WIRE ® TRUNK (TYP.) 1 " DIA. X 36" GALV. IRON PIPE ANCHOR W/ CAP ON TOP. ONE AT EACH TIE (3 REQ.) TOP OF PIPE TO BE 1" BELOW FINISHED GRADE FINISHED PLANTING AT SHRUB AREAS. SET ROOTBALL CROWN 1-1/2" HIGHER THAN THE SURROUNDING FINISHED GRADE. SLOPE BACKFILL AWAY FROM ROOTBALL FOR POSITIVE DRAINAGE. KEEP MULCH 6" - 8" FROM BASE OF TREE. MULCH WATER WELL AREA TO 3" DEPTH. 6" HIGH WATER WELL AT SHRUB AREAS. I -I I II FINISHED GRADE III -II AT SHRUBS I1- _ , -3" BACKFILL BASE FIRMLY COMPACTED. FILTER FABRIC ON TOP OF GRAVEL BED, WRAP 4" UP ALL SIDES. 2X ROOTBALL 48" AT 24" BOX 60" AT 30" BOX 72" AT 36" BOX 96" AT 48" BOX SPECIMEN TREE GUY WIRE PLANTING 1 " = 1' -0" 32 9343.26 -33 HABITAT MANAGEMENT AND LANDSCAPING PERMITS: 1. A HABITAT MANAGEMENT AND LANDSCAPING PERMIT IS REQUIRED FOR THE DEVELOPMENT OF THIS PROJECT. APPLICATION SHOULD NOT BE MADE UNTIL FINAL ADMINISTRATIVE APPROVAL HAS BEEN GRANTED. o. AN APPLICATION AND AN EXTRA COPY OF THE APPROVED FINAL APPLICATION PLAN MUST BE SUBMITTED TO THIS DEPARTMENT IN ORDER TO PROCESS THE PERMIT. b. ALL EXOTIC SPECIES, I.E., BRAZILIAN PEPPER (SCHINUS TEREBIN- THIFOLIUS), PUNK TREES (MELALEUCA QUINQUENERVIA), AND CHINESE TALLOW (SAPIUM SEBIFERUM) MUST BE REMOVED AS A CONDITION OF SITE DEVELOPMENT. WHERE NECESSARY DUE TO THEIR PROXIMITY TO PROTECTED PLANT MATERIAL, HAND REMOVAL WILL BE REQUIRED. SHOULD THIS REMOVAL BE TO A DEGREE THAT A POTENTIAL FOR EROSION IS CREATED, THE AREA MUST BE RESTABILIZED WITH SUITABLE MATERIAL. c. ONCE FINAL ADMINISTRATIVE APPROVAL (FAA) HAS BEEN GRANTED, A BARRICADE INSPECTION CAN BE SCHEDULED, WHEN THE BARRICADES HAVE BEEN APPROVED THE PERMIT CAN BE TYPED AND RELEASED. TREE PROTECTION AND PRESERVATION: TREE BARRICADES AND EROSION CONTROL MEASURE REQUIREMENTS: 1. TREE BARRICADES AND /OR SILT SCREENS OR HAYBALES SHALL BE REQUIRED ALONG THE EDGES OF VEGETATED AREAS TO BE PROTECTED PRIOR TO THE ISSUANCE OF HABITAT MANAGEMENT AND LANDSCAPE PERMITS. THE LOCATION FOR EROSION CONTROL MEASURES ARE SHOWN ON THE CONSTRUCTION DRAWINGS. 2. ALL DESIRABLE TREES MUST BE RETAINED WHEREVER POSSIBLE. IT WILL BE REQUIRED THAT PROPOSED IMPROVEMENTS (i.e. BUILDINGS, WALKWAYS, DRIVEWAYS, POND BANKS, DRAINAGE SYSTEMS, ETC.) BE ADJUSTED TO RETAIN DESIRABLE TREES. GRADE CHANGES MUST BE SENSITIVE TO TREES REMAINING. IN GENERAL, NO GRADE CHANGES SHOULD OCCUR WITHIN THE CANOPY DRIP LINE OF PINE TREES AND 2/3 THE CANOPY DRIP LINE OF HARDWOOD TREES TO BE SAVED. LANDSCAPING 1. EACH LANDSCAPING AND REPLANT TREE MUST BE PLANTED WITHIN A MINIMUM FIVE (5) FOOT BY TEN (10) FOOT OPEN SPACE PLANTER WITH SUITABLE GROUND COVER. LANDSCAPE TREES MUST BE PLANTED IN SAME VICINITY AS VEHICULAR USE AREAS IN ORDER TO BREAK THE MONOTONY OF UNBROKEN EXPANSES OF PAVING. TREES MUST NOT BE PLANTED WITHIN MAINTENANCE EASEMENTS. 2. THE USE OF XERISCAPE DESIGN MUST BE UTILIZED FOR THE REQUIRED LANDSCAPE DESIGN. THE DESIGN DEMONSTRATES THE USE OF A LOW VOLUME IRRIGATION SYSTEM, ORGANIC MULCHES, DROUGHT AND COLD TOLERANT PLANT MATERIAL, ZONING OF PLANT MATERIAL BY WATER REQUIREMENTS, SOIL AMENDMENTS (IF NECESSARY) AND THE PRACTICAL USE OF TURF. 3. NEW LANDSCAPING MUST BE PROTECTED FROM VEHICULAR MOVE - MENT BY WHEEL STOPS, OR CURBING. WHERE POSSIBLE, THE AREA BETWEEN THE BARRIER AND LANDSCAPE MATERIAL SHOULD REMAIN AS GREENSPACE. 4. LARGE TREE SPECIES PROPOSED FOR INSTALLATION MUST BE A MINIMUM OF 20 FEET AWAY FROM BUILDINGS, SIGNS, FENCES, LIGHT POLES, UTILITY LINES AND ANY OTHER OBSTRUCTIONS THAT MAY IMPAIR NATURAL GROWTH. 5. TREES PROPOSED FOR INSTALLATION MUST NOT BE IN CONFLICT WITH PROPOSED OR EXISTING UTILITY LINES OR STRUCTURES, EASE- MENTS OR OTHER AREAS WHICH MAY REQUIRE EXCAVATION IN THE EVENT OF SYSTEM FAILURE. THESE FEATURES SUCH AS THE WATER LINES MUST REMAIN OUTSIDE THE 5' X 10' PLANTER AREA. 6. SOILS WITHIN PLANTER BEDS MUST BE SUITABLE FOR PROPOSED PLANTED MATERIAL WITH REGARDS TO pH, SOIL TEXTURE, SOIL STRUCTURE, AND SEASONAL HIGH WATER TABLE, 7. ALL LANDSCAPE MATERIAL MUST BE FLORIDA GRADE #1 OR BETTER. 8. ALL REQUIRED TREES MUST BE A MINIMUM OF 10' HIGH, 2 1/2" CALIPER AT TIME OF PLANTING. 9. ALL HEDGES MUST BE 24" HIGH AT THE TIME OF PLANTING, PLANTED AT 36" ON CENTER, AND BE MAINTAINED AT A MINIMUM OF 3' IN HEIGHT, 10. WHERE LANDSCAPE OR REPLANT TREES ARE PROPOSED TO BE PLANTED IN THE PERIMETER BUFFER, THE BUFFER MUST BE A MINIMUM OF 5' WIDE. IRRIGATION NOTES 1. SHALLOW WELLS, OPEN SURFACE WATER BODIES, OR RECLAIMED WATER MUST BE USED AS A SOURCE OF IRRIGATION WATER. THE DIST- RIBUTION SYSTEM FOR IRRIGATION MUST NOT BE CONNECTED TO COUNTY OR MUNICIPAL WATER SOURCES, UNLESS IT CAN BE DEMON- STRATED THAT THESE SOURCES ARE NOT AVAILABLE. 2. IRRIGATION SYSTEMS MUST UTILIZE LOW VOLUME DESIGNS SUCH AS LOW TRAJECTORY HEADS OR SOAKER HOSES TO PROVIDE DIRECT AP- PLICATION AND LOW EVAPORATION. SYSTEMS THAT OVERSPRAY AREAS THAT DO NOT REQUIRE IRRIGATION, SUCH AS PAVED AREAS WILL NOT BE ACCEPTABLE. HIGH IRRIGATION NEED AREAS MUST NOT OVERSPRAY LOW NEED AREAS, 3. HIGH WATER DEMAND LANDSCAPE AREAS SUCH AS TURF MUST BE SERVED BY A SEPARATE IRRIGATION ZONE THAN LOW WATER NEED PLANTER BEDS, OR MULCHED AREAS WITH TREES. IN NO CASE, SHALL ANY PLANTED VEGETATION AREA BE MORE THAN 50' FROM A WATER SUPPLY HOSE BIBB. 4. AUTOMATIC IRRIGATION SYSTEMS MUST BE OPERATED BY AN IRRI- GATION SYSTEMS OPERATED BY AN IRRIGATION CONTROLLER CAPABLE OF DIFFERENTIATING BETWEEN THE SCHEDULES OF HIGH AND LOW WATER DEMAND AREAS. CONTROLLERS MUST HAVE MULTIPLE CYCLE START CAPACITY AND A FLEXIBLE CALENDAR PROGRAM ABLE TO BE SET TO COMPLY WITH LOCAL OR WATER MANAGEMENT DISTRICT IMPOSED RESTRICTIONS. 5. AUTOMATIC IRRIGATION SYSTEMS MUST BE EQUIPPED WITH RAIN SENSOR DEVICE OR SWITCH WHICH WILL OVERRIDE THE IRRIGATION CYCLE OF THE SPRINKLER SYSTEM WHEN ADEQUATE RAINFALL HAS OCCURRED. IRRIGATION NOTES (CONTINUED THE IRRIGATION CONTRACTOR SHALL PROVIDE AN UNDERGROUND IRRI- GATION SYSTEM TO COVER 1007 OF ALL ON SITE PLANTING AREA, THIS SYSTEM SHALL CONTAIN BUT NOT LIMITED TO THE FOLLOWING: 1. UNDERGROUND PIPING, SHALL BE PVC SCHEDULE 40 OR BETTER. 2. SEVEN (7) DAY PROGRAMMABLE TIME CLOCK TO ACTIVATE ZONES. 3. SPRINKLER HEADS COMPATIBLE WITH THE TYPE OF PLANTING. 4. ELECTRIC VALVES. 5. GAUGE 14 OF COPPER WIRE. 6. FIBERGLASS OR PLASTIC ZONE VALVE BOXES. WHERE PIPING IS UNDER DRIVEWAY AND CONCRETE WALKS, THE PIPES SHALL BE INSTALLED IN SCHEDULE 40 SLEEVES 18" BELOW GRADE. MATERIALS SUPPLIED SHALL BE EQUAL TO THOSE MANUFACTURED BY RAIN BIRD CO. OR APPROVED EQUAL. THE CONTRACTOR SHALL SUBMIT A SYSTEM LAY -OUT ALONG WITH CATALOG SHEETS OF ALL COMPONENTS IN THE SYSTEM TO THE OWNER FOR APPROVAL PRIOR TO INSTALLATION. THE ENTIRE SYSTEM SHALL BE GUARANTEED BY THE CONTRACTOR FOR ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE ARCHITECT/ ENGINEER. ANY AND ALL USE OF HOSE BIBBS IN ASSOCIATION WITH NON- POTABLE WATER SUPPLIES SHALL BE IN FULL COMPLIANCE WITH SBCCI STANDARD PLUMBING CODE, CHAPTER VI CRITERIA REFERENCE COLOR CODING OF ABOVE GRADE RISER PIPING AND LABEL /TAGGING OF OUTLETS AS NON- POTABLE WATER SUPPLY. ANY BUILDING TO BE DEMOLISHED IS SUBJECT TO NOTIFICATION TO THE AIR TOXICS SECTION OF THE COUNTY DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO ANY DEMOLITION OF BUILDINGS. XERISCAPING 1. ORGANIC MULCHES AND /OR DROUGHT TOLERANT GROUNDCOVERS WITHIN PROPOSED LANDSCAPE PLANTER BEDS. 2. DROUGHT AND COLD TOLERANT PLANT MATERIAL. 3. GROUPING OR ZONING PLANT MATERIAL BASE ON SIMILAR WATER REQUIREMENTS AND THE LOCATION OF PROPOSED IRRIGATION WATERING SYSTEMS. 4. THE USE OF SOIL TESTING TO IDENTIFY SOIL CONDITIONS NECES- SARY FOR THE CONTINUED SURVIVAL OF PROPOSED LANDSCAPING. 5. ORGANIC SOIL AMENDMENTS (SUCH AS TOP SOILS, MANURE'S, PEAT AND COMPOSTED MATERIALS) MIXED EXISTING SOILS WITHIN LANDS- CAPING PLANTER BEDS TO DEPTHS CONSISTENT WITH THE ROOT DEPTH OF PROPOSED PLANTED MATERIAL (USE ONLY IF EXISTING SOIL CONDITIONS WARRANT THESE AMENDMENTS). 6. THE PRESERVATION AND INCORPORATION OF EXISTING PLANT COMMUNITIES ON SITE INTO THE LANDSCAPE PLAN. 7. THE MINIMAL USE OF TURF GRASSES WHICH REQUIRE FREQUENT IRRIGATION. S. LOW- MAINTENANCE DESIGN. TREE & SHRUB PLANTING DETAILS 1. THE ROOT MASS FORM OF EACH TREE PROPOSED FOR INSTALLATION SHALL BE BALLED OR BURLAPPED, BARE ROOT TREES ARE NOT AC- CEPTABLE. ALL NONBIODEGRADABLE WRAPPINGS WILL BE REMOVED AND BURLAP WILL BE FOLDED DOWN TO ENHANCE WATER ABSORPTION. IF WIRE BASKETS ARE USED IN CONJUNCTION WITH BALLED AND BURLAPPED TREES. THE FIRST FEW ROWS OF EACH BASKET WILL BE REMOVED AT THE TIME OF INSTALLATION. 2. SUPPORTING APPARATUS SHALL BE REMOVED AFTER 1 COMPLETE GROWING SEASON. ALSO THE FLEXIBLE ATTACHMENTS SHALL BE USED WHERE SUPPORT WIRES ARE WRAPPED AROUND TREE TRUNKS /STEMS TO PREVENT CAMBIAL DAMAGE, 3. PLANTING HOLES ASSOCIATED WITH PROPOSED TREES MUST SLOPE (NOT COMPACTED) AND A MINIMUM OF 18 -24 INCHES WIDER THAN THE DIAMETER OF THE ROOT BALL. TREES SHALL BE INSTALLED SUCH THAT THE TOP OF THE ROOT MASS IS LEVEL WITH THE SURFACE OF THE PLANTING HOLE, TREES SHOULD BE INSTALLED 3 - 5 INCHES ABOVE GRADE ON SITES CONTAINING CLAY. A 2 - 3 INCH LAYER OF ORGANIC MULCH MUST ALSO BE PLACED OVER THE ENTIRE SURFACE OF EACH PLANTING HOLE. TO PREVENT FUNGAL INFECTION MULCH SHOULD BE PULLED BACK A FEW INCHES FROM THE BASE OF EACH TREE. 4. IF ON SITE SOIL CONDITIONS ARE SUCH THAT SOIL AMENDMENTS WILL BE NECESSARY, THE PLANTING MUST INCLUDE SOIL MIXTURE THROUGHOUT THE ENTIRE SECTION OF EACH PLANTER AREA TO A DEPTH CONSISTENT WITH THE ROOT DEVELOPMENT OF PROPOSED PLANT MATERIAL. 5. PLANTERS ADJACENT TO OR WITHIN VEHICULAR USE AREAS MUST BE CONSTRUCTED SUCH THAT LIMEROCK, ASPHALT, CONCRETE OR ANY OTHER OBSTRUCTIONS DO NOT EXTEND UNDER THE SURFACE INTO THE PLANTING AREAS. 6. THE PRACTICE OF TREE TRUNK WRAPPING AND THE APPLICATION OF PAINTS /TAR ONTO PRUNED TREE BRANCHES IS NOT RECOMMENDED BY THE INTERNATIONAL SOCIETY OF ARBORICULTURAL, 7, PLEASE NOTE THAT THE USE OF FERTILIZERS DURING PLANT INSTALLATION IS NOT APPROVED. SCIENTIFIC EVIDENCE INDICATES THAT FERTILIZATION (SPECIFICALLY, THE APPLICATION OF NITROGEN) OF TREES /SHRUBS WITHIN THE FIRST GROWING SEASON INHIBITS ROOT GROWTH. THE LANDSCAPE BUFFER STRIP MUST BE CONSTRUCTED SUITABLE FOR PLANT MATERIAL INSTALLATION, Z 1 Q Mo 4v F v3 I 0 0%71 IL 94 Z%0 4 X0 W� o► C • pip 0 a I MU �i Z �v W H� Z o 1 W Z �/ • 0 M V 0► Z WN Z Z �M M JQ d at it Z c� J �W �3 id U,4 B #5936 o AM �0 ES Comm.: 2007 -P Drawn By: B.J.V. Checked By: H.G. ssue Date: 42407 Revisions: y J a W O CIO W H O Z W a a v h AL BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 - 521 -1684, FAX: 727 - 527 -7422, E -MAIL: RONSPLANSOTAMPABAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist FL -1235A C i Z W s' CM LU Z W Z 0 CM 0 W OrCu,,,,,, W W CJ H Uj CO3 Lu s_ m � W O °oJ L;Z MV ILI m2 ILI m2 1r I' a: U�' U: (i f�. l_ u (X: a c� c C\ r\ I; I u I a: ,r n' m �r r� r I� 1' u: S G CL r` r- ELEVATION TO Magn :.IM L o� 0 Q) co ROOT PROTECTED ZONE \ II CC) o L ASPHALT PANEIviENT 20'X20' SIGHT TREE PRESERVATION TABLE RAINBOW DRIVE +F) 250.00' (P) 250.05' (F) 2' CONCI CURB A c, P N A. I T TREE ELEVATION TO I I' � TREE ELEVATION TO 14' TREE BARRICADES TREE AERATION (WANE 3000) CONCRETE ROOT PRUNE �� ROOT PROTECTION ZONE TREE LEGEND O 12" OAK TREE 12 " PINE TREE 12 " PALM TREE ❑ 12 "' ;EE SCAN (TYP) PY BUSH i z W z o0 cp 0 � L.1 L o� 0 Q) co ROOT PROTECTED ZONE \ II CC) o L ASPHALT PANEIviENT 20'X20' SIGHT TREE PRESERVATION TABLE RAINBOW DRIVE +F) 250.00' (P) 250.05' (F) 2' CONCI CURB A c, P N A. I T TREE ELEVATION TO I I' � TREE ELEVATION TO 14' TREE BARRICADES TREE AERATION (WANE 3000) CONCRETE ROOT PRUNE �� ROOT PROTECTION ZONE TREE BARRICADE DETAIL IQ �" v 1" X 4" Horizontal Wood Members or 6' — 8' Approved Substitute 4 2" x 2" Vertical Wood Stokes Barriers Placed at Protective Radius 2 /3rd's dripline for hardwoods (6'min) full dripline for pines (6'min) TREE BARRICADE DETAIL N.T.S. TREE LEGEND O 12" OAK TREE 12 " PINE TREE 12 " PALM TREE ❑ 12 "' ;EE SCAN (TYP) PY BUSH i TREE BARRICADE DETAIL IQ �" v 1" X 4" Horizontal Wood Members or 6' — 8' Approved Substitute 4 2" x 2" Vertical Wood Stokes Barriers Placed at Protective Radius 2 /3rd's dripline for hardwoods (6'min) full dripline for pines (6'min) TREE BARRICADE DETAIL N.T.S. 1 I= ,I 01 a: I W T, �I U J W1 M1 24" RCP I SCALE: 1"=10' zo 4 � 1pj 0; � K F "F 1� 0% . so P4 X MU W v 0 a ' W z W V p e M z M Z M e d 0 0 wig Z � A t d V B #5936 o V w I ES Comm.: 2007 -P Drawn By: B.J.V. hecked By: H.G. TREE LEGEND O 12" OAK TREE 12 " PINE TREE 12 " PALM TREE ❑ 12 "' OTHER TREE_ (AS LABEIE.-D) O BUSH 1 I= ,I 01 a: I W T, �I U J W1 M1 24" RCP I SCALE: 1"=10' zo 4 � 1pj 0; � K F "F 1� 0% . so P4 X MU W v 0 a ' W z W V p e M z M Z M e d 0 0 wig Z � A t d V B #5936 o V w I ES Comm.: 2007 -P Drawn By: B.J.V. hecked By: H.G. z O Q W W W am W W BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 -521 -1684, FAX: 727 - 527 -7422, E— MAIL:RONSPLANS•TAMPASAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist : FL -1235A `7 z w slue Date: 4 -24-07 Revisions: No. Date Description I O 06 07 CITY COMMENTS z W z o0 cp 0 UJ LL. W W� v LLI Cn W Q = in z MV z O Q W W W am W W BUTLER DESIGN GROUP, INC GOLDEN RAIN NURSERY, INC. 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 H 727 -521 -1684, FAX: 727 - 527 -7422, E— MAIL:RONSPLANS•TAMPASAY.RR.COM DRAWN BY: RON BELKO CHECKED BY: CHUCK BUTLER Certified Arborist : FL -1235A `7 z w W z W z o0 cp 0 UJ LL. W W� v LLI Cn W Q = in z MV L1.31 a- .i Il C s U V V C I+ C C C I I, 1F'I AI'ICI kDIVI`:�I�?I`�1. �:Is, I�I,_�wn l -� 1.I�Ir� F'Illt tlt 'I:I�_�f� I= l :It +11 FII II.IIi,- Rey- ;_�rl_I � �t F''i I�_�Ikil ' FPK &D LB #208 0 SECTION 13 TOWNSHIP 29 SOUTH • RANGE 15 EAST PINELLAS COUNTY, FLORIDA FIP 1® - -- - - - -W- - -- - -- _9H�- - - - - -- OHW.--- --------- mow- - -- - -- - - - -- -- -- W - - - -- - -- - - -OHW - -- -- - -- OHW OHW OHW OHW FPK &D LBI #208 I I III STORM MANHOLE I I RIM = 73.18 INV N 70.33 D C FOUND D LB #208 LL* 0 r /1 /\ n;v UJ w 0 5) 000 99 ASPHALT FOUNC DISC (ILLEGABILE) n CHIN 2' CONC CURB SANITARY MANHOLE ; RIM = 73.70 INV S - 88.98 RAINBOW _ DRIVE LB #208 N � � ASPHALT PAVEMENT - SANITARY MANHOLE RIM = 73.59 INV 69.04 - SANITA 8 Y 6fANHOLE INV S 69.04 u� RIM,- 73.12 INV W = 69.04 �� N8922'44 °W (P +F) 250.00' (P) 250.05' (F) 2' CONC CURB _. CONS WALk' FCM 3 "x3" 1 TREE CANOPY N TYP I GRASS. di os . O 0 TIE IN NOT ROOF OVERHANG 4- FIELD VERIFIED I YON 4- - - - - - - - - - 39.T (L UL_ WI Z %-0 BACK FLOW 3i U 3 PREVENTOR tUe 2.5'x2.5' CONC W a U COLUMNS (TYP) N p / j 0 0 r r o0 n J ONE STORY MASONRY it �• •. • 00 .II WM FINISHED FLOOR ELEV = 75.25 V W 0 AIL I _j STORM MANHOLE a Z co G R A S S RIM . 73.62 INV E - 59.46 ll INV W = 59.56 0 INV N - 69.95 MV S 70.00 • Q 20" M E T Z (DAM ACE) D - - - 24 RCP - - - CONC -- 49.4• 1 .3 - • II �• 40.4' I c o PLANTER -- FCM 3 "x3" x ---7t- c. all . 6 CHAIN LINK FENCE 8891°22'44'8 , (P) 250.00' (P +F) 88922'10 "E 1 _ _ I A S P H A LF FCM 4•x4" FOM 4 "x4" (POLARIS) n SL .S GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. TREE INVENTORY NOTES LEGEND p TRAFFIC SIGNAL ACCESS BOX 012 OAK TREE N o S C A L E O00 CLEANOUT v �Q> �Q ® GAS METER ( PINE TREE ® GAS VALVE �O F- C) vWQICEL PALM TREE US SANITARY MANHOLE ❑1Z OTHER TREE (AS LABELED) © GREASE -TRAP MANHOLE D �O vjmo� 0 BUSH O ELECTRIC MANHOLE UNK UNKNOWN Op STORM MANHOLE FND SC FOUND SET 1/2" CAPPED IRON ROD "LB 4513" ® WATER VALVE FIR FOUND IRON ROD (SIZE NOTED) ® RECLAIMED WATER VALVE FCIR FOUND CAPPED IRON ROD (SIZE NOTED) ® WATER METER BOX FRR FOUND RAILROAD SPIKE ® RECLAIMED WATER METER BOX PK PARKER KAYLON NAIL _am. -toa FCM FOUND CONCRETE MONUMENT (SIZE NOTED) iCV IRRIGATION CONTROL VALVE FOP FOUND OPEN -ENDED IRON PIPE (SIZE NOTED) rx FPP FOUND PINCHED -TOP IRON PIPE (SIZE NOTED) O or O FIRE HYDRANT FN&D FOUND NAIL & BRASS DISK LIGHT POLE SN&D SET NAIL IN BRASS DISC "LB 4513" WOOD UTILITY POLE ID PLS IDENTIFICATION PROFESSIONAL LAND SURVEYOR 0 CONC UTILITY POLE LB LICENSED BUSINESS QT TELEPHONE BOX P PLAT ® CABLE TV BOX D F DESCRIPTION FIELD MEASURED EE ELECTRIC BOX O.R. OFFICIAL RECORDS (BOOK) SIGN PG PAGE SPRINKLER HEAD PB PLAT BOOK o"O ROOF DRAIN Cp CALCULATED FROM PLAT CALLS 4 LANDSCAPING LIGHT Cf CALCULATED FROM FIELD SURVEY POS POINT OF BEGINNING -WATERS UNDERGROUND UTILITY PAINT MARK (AS LABELED) POC POINT OF COMMENCEMENT P.U. PUBLIC UTILITIES EASEMENT R/W RIGHT -OF -WAY D.E. DRAINAGE EASEMENT q_ CENTERLINE MH MANHOLE E/P EDGE OF PAVEMENT EL ELEVATION BOC BACK OF CURB INV. T.O.P. INVERT TOP OF PIPE HWY HIGHWAY UG UNDERGROUND BLVD CONC BOULEVARD CONCRETE U . M.E.S. UNDERDRAIN MITERED END SECTION ASPH ASPHALT F.E.S. FLARED END SECTION EM ELECTRIC METER RCP REINFORCED CONCRETE PIPE CLF CHAIN LINK FENCE ERCP ELLIPTICAL REINFORCED CONCRETE PIPE BWF BARBED WIRE FENCE CMP CORRUGATED METAL PIPE WPF WOOD PLANK FENCE DIP DUCTILE IRON PIPE A/C AIR CONDITIONER PVC POLYVINYLCHLORIDE PIPE R. R. RAILROAD GTE GENERAL TELEPHONE AND ELECTRONICS TOB TOP OF BANK TELE. TELEPHONE TOS TOE OF SLOPE OHW DTELEPHONE TLI A SERVICE E(S)N AND/OR F.F. FINISH SHE FLOOR F.O.C. FIBER -OPTIC CABLE L. F. LOWEST FLOOR GUY GUIDE WIRE DIA. DIAMETER ® NUMBER OF PARKING SPACES SECTION 13 TOWNSHIP 29 SOUTH • RANGE 15 EAST PINELLAS COUNTY, FLORIDA FIP 1® - -- - - - -W- - -- - -- _9H�- - - - - -- OHW.--- --------- mow- - -- - -- - - - -- -- -- W - - - -- - -- - - -OHW - -- -- - -- OHW OHW OHW OHW FPK &D LBI #208 I I III STORM MANHOLE I I RIM = 73.18 INV N 70.33 D C FOUND D LB #208 LL* 0 r /1 /\ n;v UJ w 0 5) 000 99 ASPHALT FOUNC DISC (ILLEGABILE) n CHIN 2' CONC CURB SANITARY MANHOLE ; RIM = 73.70 INV S - 88.98 RAINBOW _ DRIVE LB #208 N � � ASPHALT PAVEMENT - SANITARY MANHOLE RIM = 73.59 INV 69.04 - SANITA 8 Y 6fANHOLE INV S 69.04 u� RIM,- 73.12 INV W = 69.04 �� N8922'44 °W (P +F) 250.00' (P) 250.05' (F) 2' CONC CURB _. CONS WALk' FCM 3 "x3" 1 TREE CANOPY N TYP I GRASS. di os . O 0 TIE IN NOT ROOF OVERHANG 4- FIELD VERIFIED I YON 4- - - - - - - - - - 39.T (L UL_ WI Z %-0 BACK FLOW 3i U 3 PREVENTOR tUe 2.5'x2.5' CONC W a U COLUMNS (TYP) N p / j 0 0 r r o0 n J ONE STORY MASONRY it �• •. • 00 .II WM FINISHED FLOOR ELEV = 75.25 V W 0 AIL I _j STORM MANHOLE a Z co G R A S S RIM . 73.62 INV E - 59.46 ll INV W = 59.56 0 INV N - 69.95 MV S 70.00 • Q 20" M E T Z (DAM ACE) D - - - 24 RCP - - - CONC -- 49.4• 1 .3 - • II �• 40.4' I c o PLANTER -- FCM 3 "x3" x ---7t- c. all . 6 CHAIN LINK FENCE 8891°22'44'8 , (P) 250.00' (P +F) 88922'10 "E 1 _ _ I A S P H A LF FCM 4•x4" FOM 4 "x4" (POLARIS) n SL .S GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. TREE INVENTORY NOTES --= T1'f_E I'I P`��, 1,'1 T 1`1E ITTE CiEH ° C N L'> Lj v �Q> �Q I ti- \Il Q 0 ( T(_F`i E',,.TII 11, =; �O F- C) vWQICEL U �,c�UaaQ Tree Inventory by: BUTLER DESIGN GROUP, INC 4203 46TH AVE. N. ST. PETERSBURG, FL. 33714 PH 727 - 521 -1684, FAX: 727 - 527 -7422, E- MAIL: BDG1®TAMPABAY.RR.COM DRAWN BY: RON BELKO DESIGNED /CHECKED BY: CHUCK BUTLER ISA CERTIFICATION # FL -1235A AFOX: ' 1. TYPE OF SURVEY: BOUNDARY AND TOPOGRAPHIC SURVEY 2. LAST DATE OF SURVEY: APRIL 13, 2007. 3. SURVEY CREW: TOM RYAN, SCOTT WILLIAMS and JEREMY McCLOUD. 4. ELEVATIONS SHOWN HEREON ARE IN FEET AND REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.). 5. REFERENCE BENCHMARK IS A BOX CUT ON INLET AT THE NORTHEAST CORNER OF BELCHER ROAD AND DREW STREET, ELEVATION = 72.706. 6. THE LOCATION OF EXISTING UNDERGROUND INSTALLATIONS OR IMPROVEMENTS HAS BEEN LIMITED TO THE ABOVE GROUND EVIDENCE OF SUCH IMPROVEMENTS, EXCEPT AS SHOWN OTHERWISE. 7. BASIS OF BEARINGS: THE SOUTH RIGHT -OF -WAY LINE OF RAINBOW DRIVE BEING N89'22'44 "W PER PLAT. 10. THE SURVEY WAS PREPARED WITH THE BENEFIT OF A CURRENT TITLE COMMITMENT PROVIDED BY FIDELITY NATIONAL TITLE INSURANCE COMPANY , ESCROW NO. FT54- 07001822, DATED MARCH 19, 2007 AT 8:00 A.M. � W 0) _ U_ ll�p _ 0 0- Z V ZMM W 0. *6 WW O F jR (n Z + WW >. U Q U. 0 5 W M W ` r` 0 N � ° 0 z U � o v CL 0 1 0 rn 3 N O d O Y LLJ U 0 Z 3 v � Q � v � r � � V � W o- Ln ui 0 d W LL O LLJ H Q FW- C Q m 0 Li Z rE W Z Z W U �--, ry w W J (_0 0 m V 1 LL] Q y _j Li :2 J [r ^ 0 V 1 � L) r� V ) I- o 00 Ld (n Ln z 00 0 U Cn O X U Q U_ ch N Q 0 I 0 Ln 00 Elf Q 00 z 0 n m A W J )zQ 0 O � U ° C N L'> Lj v �Q> �Q zOw Q 0 Fn H Cla-Fnln Li voc)L Vi �O F- C) vWQICEL U �,c�UaaQ �QZ Q� = L 0-1 }U a �p �1 co D �O vjmo� 0 pq In Z�+ _=0 UQip N I Q m ¢L WOZ ^� [) � Q�N Vi 0 r0�n W Er ° .L y iE m d C7 > T"� a� Z J EY cln u =v tno O v ° .0O c > E Wv ° 0 3 t J L `vt 'w In j Q Y _am. -toa U �--, ry w W J (_0 0 m V 1 LL] Q y _j Li :2 J [r ^ 0 V 1 � L) r� V ) I- o 00 Ld (n Ln z 00 0 U Cn O X U Q U_ ch N Q 0 I 0 Ln 00 Elf Q 00 z 0 n m A W J ^U �° 1y 2' CONC CURB Revisions: No. Date Description 15� 10/06 07 �I LL w I I /--STORM MANHOLE 1a. ! RIM = 73.18 N = 70.33 SANITARY MANHOLE PER PIN. CO. ^OINV p L RIM = 73.70 j ti° o 7/09/08 INV S = 68.98 DC I ' UJ �h 0H W --- EX1S TING POST OFFICE _ —_OHW -- — - —. — .- T1 - -- — -- OHW - -- -- -- OHW = — — — OHW — — — — OHW — — -- — OHW — �- �. — OHW POSONAL Q POSITION v Of b SILT r FLOW 1111°111I -III I -1 SILT BARRIER DETAIL N.T.S. POST OPTIONS: 2 °x4" OR 2.5 "DIAM. WOOD; 1.33LBS. /FT. MIN. STEEL FILTER FABRIC IN CONFORMANCE WITH SEC. 985 F.D.O.T. SPECS. OR EQUAL EXIST. GROUND PRINCIPLE POST POSITION, CANTED 20' TOWARD FLOW FILTER FABRIC EXIST. GROUND NOTE: SILT FENCE SHALL NOT BE TRENCHED IN WHERE ADJACENT TO TREES DESIGNATED TO REMAIN. THE SILT FENCE MUST BE SECURED THROUGH THE PLACEMENT OF FILL OVER THE LOWER LIP OF THE BARRICADE. ry ,o �o X17) _ 15' • L� 1a � 6 1a� b 2' CONC CURB Revisions: No. Date Description 15� 10/06 07 of 1, �5h 1a. w a SANITARY MANHOLE PER PIN. CO. p PER PIN. CO. RIM = 73.70 j BLDG. COMMENTS 7/09/08 INV S = 68.98 DC I ' UJ RAINBOW DRIVE - - - -- - - -- - -- S — - Ja W� Ln •�° o ASPHALT PAVEMENT I 1 SANITARY MANHOLE — � RIM = 73.59 rp RIM - 73.82 ' INV N = 69.04 INV W - 69.56 I INV S = 69.04 \ UX 3 ' 3 INV W = 69.04 /II AA 2'44'W iP�-F 250.00' (P) 2fQ05' (F) P -- -- —� - -f� 1 15 2' CONC CURB ry51j. 1�.1y I1�^yO cy0 1>C1 m W O ,�1 (0 CID vt ryG POSONAL Q POSITION v Of b SILT r FLOW 1111°111I -III I -1 SILT BARRIER DETAIL N.T.S. POST OPTIONS: 2 °x4" OR 2.5 "DIAM. WOOD; 1.33LBS. /FT. MIN. STEEL FILTER FABRIC IN CONFORMANCE WITH SEC. 985 F.D.O.T. SPECS. OR EQUAL EXIST. GROUND PRINCIPLE POST POSITION, CANTED 20' TOWARD FLOW FILTER FABRIC EXIST. GROUND NOTE: SILT FENCE SHALL NOT BE TRENCHED IN WHERE ADJACENT TO TREES DESIGNATED TO REMAIN. THE SILT FENCE MUST BE SECURED THROUGH THE PLACEMENT OF FILL OVER THE LOWER LIP OF THE BARRICADE. ry ,o �o X17) _ 15' • L� 1a � 6 1a� b Issue Date: 4 -24-07 Revisions: No. Date Description 15� 10/06 07 of 1, �5h 1a. w a Ir PER PIN. CO. W~ PER PIN. CO. A2/11/08 BLDG. COMMENTS 7/09/08 0- DC UJ a a Ja W� Ln •�° /h Z 1�STORM MANHOLE / / RIM - 73.82 INV E - 69.48 INV W - 69.56 W INV N - 69.95 INV S - 70.00 — 24 RCP P Z a p� W A�. m W O ,�1 (0 CID vt ryG Ix vILU C) > ca Lu Cc b� plow In 3: z Llj M 'w =O 0 w w 1` I GULF TO BAY BLVD. "I ACKNOWLEDGE THE PLACEMENT & IPCATION OF ALL MEASURES THIS PLAN REQUIRES TO CONTROL TURBIDITY & EROSION WR THIS SITE. THIS PLAN SHALL BE MADE AVAILABLE TO SITE CONTRACTOR" ATE: JUL 10 2998 NOTE: SILT FENCES AND EROSION CONTROL MEASURE MUST BE PLACED PRIOR TO CONSTRUCTION AND BE MAINTAINED THROUGH THE PROJECT �o I I h REMOVE.• CONCRETE ASPH. & 84SE DEMOLITION OF THE SITE INCLUDES THE REMOVAL /RELOCATION OF ALL EXISTING STRUCTURES WITHIN PROJECT AREA, PAVING AND BASE, UTILITY LINES (SANITARY SEWER, STORM PIPES, WATER LINES, POWER POLES, OVERHEAD AND UNDERGROUND POWER AND TELEPHONE CABLES, GAS LINES, TREES, SHRUBS, ETC.) AND IS NOT LIMITED TO WHAT'S SHOWN. 10 REMOVE CONCRETE PADS AND CONCRETE WALKS TO THE NEAREST EXPANSION JOINT. REMOVE ASPHALT AND BASE, 30 REMOVE EXISTING SIGN. -1 REMOVE EXISTING CURBING 5 ALL CAVITY & EXCAVATION RESULTING FROM REMOVAL OF TREES, SHRUBS, PIPES, INLETS, GREASE TRAPS, SIGN, AND POLE BASE SHALL BE FILLED WITH APPROVED SUITABLE MATERIAL AND COMPACTED IN 12" LIFTS TO 95% OF MAX DENSITY, 6 OFF -SITE DISPOSAL OF STRUCTURES, UTILITIES AND CONSTRUCTION DEBRIS SHALL OCCUR IN SOLID WASTE DISPOSAL FACILITIES APPROVED BY F.D.E,P., AND CITY OF CLEARWATER. 7 CARE IS TO BE USED WHEN REMOVING WALKWAYS AS TO NOT DISTURBED COLUMNS. C��ncE.,u) T111101-01 RECEIVED JI L 1 1008 rMILOFMINT :I NRIGHBORS000 slmviarxs Oifiv of 4LBAHWATIM SCALE: 1"=20' 20 THIS DRAWING IS AN INSTRU 0 Fi?5 ENGINEER, AND SHALL NOT . E DUG�D, ` THE CONSENT OF THE ENGI • RAM A. G COPIES OF THESE P EMBOSSED WITH THE SIGN Q 00 dom d z x L4 N • f1 Z M VU Z nW lb Z W W • V IA z °<" z M 4 oG IL zW � N • O� id NW E6 #5935 V MV °o 5 NES Comm.: 2007 -P Drawn By: B.J.V. Checked By: H.G. Z W Z J 0 W ; p ` PuRTY OF THE flIt WITHOUT 11DLISHED Al 1 Issue Date: 4 -24-07 Revisions: No. Date Description 10/06 07 CITY COMMENTS Al2/19/07 PER PIN. CO. w a 1/2/08 PER PIN. CO. 1/24/08 PER PIN. CO. A2/11/08 BLDG. COMMENTS 7/09/08 CITY OF CLW. DC W C' Z / / Z W Z J 0 W ; p ` PuRTY OF THE flIt WITHOUT 11DLISHED Al 1 FC2I I w w J •- c M cnZN w a W Cj DC W C' Z W W C' Z a p� W oa m W O �� WLA. (0 CID vt Ix vILU C) > ca Lu Cc W 4x plow In 3: z Llj M 'w =O 0 w w h _j O z OJ M Cj W z w mOYw 140 ly O V) C4 0co0 FC2I I w w J •- c M cnZN EXIST!NG POST OFFICE Djw QHW OHW OHW QHW OHW QHw 2' CONIC CURB SANITARY MANHOLE RIM = 73.70 INV S = 68.98 k RAINBOW DRIVE Ll , ASPHALT PAVEMENT SANITARY MANHOLE--- II c) RIM = 73.59 F—SIORM MANHOLE INV N = 69,04 ; U-1 RIM = 73.18 [—SANITARY MANHOLE INV 5 = 69.04 INv N 70.33 RIM = 73.12 INV W = 69.04 Nrl '.1 WROL STRUC A"W44'W 250.00' g4qI05'(F) lSEEOERIL) 0 2' CONC CURB 'AN,) X10 y0 Ts� 1� 54 �l bp C 0 N C z EX. 4' CONC WALK haw OHW 0H* 0HW 0 00 A13 1.\ NEW v "I I - I h. 23 0 1 " " ! . ' I N I'll i CONC. ­­ ' Yl ' 11 ' ) 4 �0' FLUME M DETAIL) 0 )cl 73.5 Aa. A o \c I o 0 ,_ >„ OAK T0Y A 12/19/07 PER PIN. CO. 1/2/08 on 0 fft rREE CAN (TYP) )PY C---- C=- C=== \-j 7/09/08 3H .A A z Z • 0 0 Nat 04 0 E #5936 v 0 a M V CO Z� .3 Lu C) M5 K) -1 . �b I I ,:� I , I %K G R A S S SICN F Y7 &H THROUGH HY� NT E X A S I, H A L T /s* �: POINT 6r' N 'X6" 0 R ROOF OVERHANG TJW 8' cr X�m CON v A 4� 1. 1p COLUMN (TYP) 16) ,N� C�, �l " PL/C jw 717 + lcFVjJ MIN. 0 tK EX Q_ AEW RETENMIN POW t.. B'FP w MZ TOP EL. 74.0 BO T. EL. 72.5 a— a, 0 Ln \11`1 Ln 0, EXISTING I —STORY BUILDING w FINISHED FLOOR ELEV = 75.2-", AREA 8.000 5F D STORM MANHOLE + LA RIM - 73.82 t., *IR A $ Si NV E 69.48 (Z�j :NV W 6956 INV N 69�95 INV $ 70.00 A S F H A L T _5" RCP ,74.3' t. TAL OAMIAGEE 0 1. qP Y L A2 .\h �l , haw \�aA CURB LL V_ x 6' CI 1 61 IN t� cb BOTTOM OF-RETENTION BASIN FLUME DETAIL N.T.S. 160' 'Y loom -m 11, P L A N 7 E R A A WIN m ROO m IN pry ki LINK FENCE 0 7 -00 'N N 0 0 10 f ��''�ll ca +,° 0.5, CdNC CURB W2244\vE (P) 250.00' (P+F) F_ XIS TING /' / I \ I EXISTING �! ^ / (` —_� ��go ^�� .,f PARKING w. A DRIVE - A S P 11 A L T Uj Jcl A 6b 4" N '.1 CONC WALK . EXIS NNG OFFICE BUILDING 4 OPENING IN CURB 12" 2 12" (SEE CURB ENDING DETAIL) A2 6"x6"x# 10 W.W.M. 3000 PSI CONCRETE � .1 N1114A ❑nT r* PAVEMENT . v ENT ON 11 " \- 6"x6"x#10 W.W.M. IN 33" COMPACTED 6-13-16-13-16-13-16- GROUND III I I I 1 6" THICK 111 3000 PSI CONIC. —III L-2" _=111=111 SECTION A2 — A2 N.T.S. NEW ASPHALT PA VEMEN T--\ -GULF TO BAY BLVD.- V. 10' 6' 3' 1 EX. A SPHA L T --PAVEMENT EL, 72.5 SECTION A-A N.T.S. BEGIN TOP OF BANK 2' FROM EDGE OF WALL (TYP) s 1/4" THICK ALUM. GREASE SKIMMER v THICK 3000 P 00 1 POURED CONC. WALL SLOPE l' FROM SLOT CONTROL STRUCTURE DETAIL H 2" 6" xx" L - - - -- 6" xx" xx" I GREASE BAFFLE TO BE 1/4" THICK ALUMINUM w/STAINLESS STEEL ANCHORS SLOT+ GREASE BAFFLE DETAIL N.T.S. SCALE: 1'%--201 20 0 10 20 .40 2 mo 4 vo 0 jL �v vill Z Q It No o f 14 z Z Z NW w id z 0 I > W Date: 4-24-07 7HEE LEGEND C) ,_ >„ OAK T0Y A 12/19/07 PER PIN. CO. 1/2/08 on 0 fft A 12 PALM TREE A 12 OTh'ER 7-1?E-E- ('A_c, LABL-1 EO) 7/09/08 3H A2 .\h �l , haw \�aA CURB LL V_ x 6' CI 1 61 IN t� cb BOTTOM OF-RETENTION BASIN FLUME DETAIL N.T.S. 160' 'Y loom -m 11, P L A N 7 E R A A WIN m ROO m IN pry ki LINK FENCE 0 7 -00 'N N 0 0 10 f ��''�ll ca +,° 0.5, CdNC CURB W2244\vE (P) 250.00' (P+F) F_ XIS TING /' / I \ I EXISTING �! ^ / (` —_� ��go ^�� .,f PARKING w. A DRIVE - A S P 11 A L T Uj Jcl A 6b 4" N '.1 CONC WALK . EXIS NNG OFFICE BUILDING 4 OPENING IN CURB 12" 2 12" (SEE CURB ENDING DETAIL) A2 6"x6"x# 10 W.W.M. 3000 PSI CONCRETE � .1 N1114A ❑nT r* PAVEMENT . v ENT ON 11 " \- 6"x6"x#10 W.W.M. IN 33" COMPACTED 6-13-16-13-16-13-16- GROUND III I I I 1 6" THICK 111 3000 PSI CONIC. —III L-2" _=111=111 SECTION A2 — A2 N.T.S. NEW ASPHALT PA VEMEN T--\ -GULF TO BAY BLVD.- V. 10' 6' 3' 1 EX. A SPHA L T --PAVEMENT EL, 72.5 SECTION A-A N.T.S. BEGIN TOP OF BANK 2' FROM EDGE OF WALL (TYP) s 1/4" THICK ALUM. GREASE SKIMMER v THICK 3000 P 00 1 POURED CONC. WALL SLOPE l' FROM SLOT CONTROL STRUCTURE DETAIL H 2" 6" xx" L - - - -- 6" xx" xx" I GREASE BAFFLE TO BE 1/4" THICK ALUMINUM w/STAINLESS STEEL ANCHORS SLOT+ GREASE BAFFLE DETAIL N.T.S. SCALE: 1'%--201 20 0 10 20 .40 2 mo 4 vo 0 jL �v vill Z Q It No o f 14 z Z Z NW w id z 0 I > W NES Comm.: 2007-P Drawn By: B.J.V. FChecked By: H.G. Date: 4-24-07 -issue Revisions: No. Date Description A10/06/07 co CITY COMMENTS A 12/19/07 PER PIN. CO. 1/2/08 on 0 fft A 1/24/08 PER PIN. CO. A L flat 7/09/08 mo .A A z Z • 0 0 Nat 04 0 E #5936 v 0 a M V NES Comm.: 2007-P Drawn By: B.J.V. FChecked By: H.G. Lu cn C*1311 Lu Old ui CD %%is I off,,,. W THIS DRAWING IS AN INSTRUM It l ROPERTY OF THE ENGINEER, AND SHALL NOT B Y WAY WITHOUT THE CONSENT OF THE ENGIN T PUBLISHED ­l,h 263 ■ Date: 4-24-07 -issue Revisions: No. Date Description A10/06/07 co CITY COMMENTS A 12/19/07 PER PIN. CO. 1/2/08 PER PIN. CO. A 1/24/08 PER PIN. CO. A 2/11/08 BLDG. COMMENTS 7/09/08 CITY OF CLW, LAJ A z Z CD 0 LLJ A L.LJ lxj CO Z� .3 Lu Lu cn C*1311 Lu Old ui CD %%is I off,,,. W THIS DRAWING IS AN INSTRUM It l ROPERTY OF THE ENGINEER, AND SHALL NOT B Y WAY WITHOUT THE CONSENT OF THE ENGIN T PUBLISHED ­l,h 263 ■ co LLI ca LAJ LLJ CD 0 LLJ a ix C) L.LJ lxj CO Lu =w ci .3 Lu C) M5 IC4.11