Loading...
509 D STS�M �s o APPLICATION FOR LAND CLEARING & GRUBBING PERMIT CITY OF CLEARWATER PLANNING DEPARTMENT (727) 5624741 DATE Z -7 If /0.2 RECEIPT O. A non - refundable filing fee of $10.00 is required. Permit applicable for 6 months from date of approval. In accordance with the Community Development Code, I hereby apply for permit to land clear and /or grub the CD property described below. 1. Location of Property: _.� 7-> 67-t400, 2. Pro)ect Name: 5E6 - 3. Purpose of clearing and /or grubbing: 0 New Construction 0 Demolition 0 Tank Removal Other 4. General description of existing vegetation, topography, and surface water (Including all existing and /or proposed - ditches, canals, and swales) g j" r r /x-, tea, AS wt—ef . C 5. Proposed method of debris disposal e- 6. Date you plan to begin work 7. Proposed method of soil erosion control _ Sc,L - r-)&zx lC kAp 10. 8. KNo -Tree Verification Required 0 Tree Removal Permit Required I AM AWARE AND UNDERSTAND THE REQUIREMENTS OF ARTICLE 3, DIVISION 12 REGARDING TREE PROTECTION DURING C UCTION AND,/ARTICLE 3, DIVISION 7 OF THE COMMUNITY DEVELOPMENT CODE REGARDING EROSI AN LTATION ROL. e of own�e�r r Own Representative Address vR�..r Kccta G.a�`o �� 33770 Printed Name city state ZIP Krd.t` �uuJT', Representatives' Firm 7Z� -G 5� •Y93� S�r7—Z,3va Telephone Cell Applicant must include Aerial Photograph or Scaled Site Plan showing pro oundarles and limits of work. This is NOT a Tree Removal Permit. DO NOT WRITE RFLOW THIS I IMF Based on the above comments and Information submitted, the above clearing & grubbing application is: 0 Approved As Submitted Approved - Modified As Noted Above 0 Denied Signed: , _ Date 0 509 D Si BCP2007 -03691 PARKING LOT & LANDSCAPING SEGWAY OF TAMPA BAY Zoninq: IRT atlas# 305B KIn NO TREE VERIFICATION or TER, NO TREE REMOVAL PERMIT REQUIRED VERIFICATION STATEMENT CITY OF CLEARWATER PLANNING DEPARTMENT . (727) 562 -4741 (Print or Type) m Owner: Act lilt ���• -�.� Phone: -W-57-3Z- i E -mail: ,/ Cell Phone: Owner's Representative: l� . �- K66A` eKAA-Mte'e'- Phone: SAI-2-366 E -mail: Cell Phone: 654 -ffl3 Address of Applicant: -7 Zo 137-d , r- W City: Z'40-a-4 State: % L Zip: 1177 0 Address of Proposed construction: SO 1 b `' cs'rge of f O Clearwater, Florida I hereby certify that the information contained herein is true and accurate and that I am the legal owner of the � subject property or have legal authority to execute this form on behalf of the property owner. I am aware that any deviation from the information submitted with this form shall be considered a violation of the Community Development Code. In accordance with Section 4 -1205, Community Development Code, I request a release from the provisions of the tree removal permit section to allow the issuance of a building permit at the above location because one of the following conditions exists: C] PROTECTED TREES EXIST ON THE SITE as defined in Section 8 -102 (non - prohibited species greater than four inches at 4,5 feet above grade), but ARE NOT REQUIRED TO BE REMOVED FOR CONSTRUCTION purposes, thus no tree removal permit is required. I further understand that these TREES MUST BE PROTECTED FROM DAMAGE BOTH BEFORE AND DURING ALL CONSTRUCTION ACTIVITIES ON THIS SITE as provided in Section 3 -1205 of the City code of Ordinances (A site plan is submitted with this request.) NO PROTECTED TREES EXIST ANYWHERE ON THE SITE of the proposed construction as defined in Section 8 -102 (non - prohibited species greater than four inches at 4,5 feet above grade). PRINTED NAME;,;aZf24Wa4—- caQ�P�l�r�- SIGNED or Signature of Owner VXepresentative 509 D ST (:LE WATER BCP2007- 03691 Frank Hibbard, Mayor PARKING LOT & LANDSCAPING r Hoyt Hamilton, Councilmember SEGWAY OF TAMPA BAY atlas# 3058 Zoning: IRT y _ �.. �elopment Services Yellow - Applicant Carlen A. Petersen, Councilmember 5 -02 IRRIGATION SYSTEM NOTES: 1. IRRIGATION SYSTEM SHALL PROVIDE 100% COVERAGE FOR ALL REQUIRED LANDSCAPING. 2. SHALLOW WELLS, OPEN SURFACE WATER BODIES, OR RECLAIMED WATER MUST BE USED AS A SOURCE OF IRRIGATION WATER. THE DISTRIBUTION SYSTEM FOR IRRIGATION MUST NOT BE CONNECTED TO CITY WATER SOURCES UNLESS IT CAN BE DEMONSTRATED THAT THESE SOURCES ARE NOT AVAILABLE. 3. IRRIGATION SYSTEMS MUST UTILIZE LOW VOLUME DESIGN SUCH AS LOW TRAJECTORY HEADS OR SOAKER HOSES TO PROVIDE DIRECT APPLICATION AND LOW EVAPORATION. SYSTEMS THAT OVERSPRAY AREAS THAT DO NOT REQUIRE IRRIGATION, SUCH AS PAVED AREAS WILL NOT BE ACCEPTABLE. HIGH IRRIGATION NEED AREAS MUST NOT OVERSPRAY LOW NEED AREAS. 4. HIGH WATER DEMAND LANDSCAPE AREAS SUCH AS TURF MUST BE SERVED BY A SEPARATE IRRIGATION ZONE THAN LOW WATER NEED AREAS, SUCH AS PLANTER BEDS, OR MULCHED AREAS WITH TREES. ALL NEW LANDSCAPING SHALL BE IRRIGATED BY AN AUTOMATED SYSTEM. 5. AUTOMATIC IRRIGATION SYSTEMS MUST BE OPERATED BY AN IRRIGATION CONTROLLER CAPABLE OF DIFFERENTIATING BETWEEN THE SCHEDULES OF HIGH AND LOW WATER DEMAND AREAS, CONTROLLERS MUST HAVE MULTIPLE CYCLE START CAPACITY AND A FLEXIBLE CALENDER PROGRAM ABLE TO BE SET TO COMPLY WITH LOCAL OR WATER MANAGEMENT DISTRICT IMPOSED RESTRICTION. 6. AUTOMATIC IRRIGATION SYSTEMS MUST BE EQUIPPED WITH A RAIN SENSOR DEVICE OR SWITCH WHICH WILL OVERRIDE THE IRRIGATION CYCLE OF THE SPRINKLER SYSTEM WHEN ADEQUATE RAINFALL HAS OCCURRED. * IRRIGATION SYSTEM SHALL MEET ALL REQUIREMENTS OF THE CITY OF CLEARWATER CODE SSECTION 3 -1203 C. ABBREVIATION LEGEND BLDG. = BUILDING CL or CE = CENTERLINE CONC. = CONCRETE D.I. = DROP INLET EL = ELEVATION FH = FIRE HYDRANT FL. = FLOOR HT. = HEIGHT INV. = INVERT MH = MANHOLE R.C.P. = REINFORCED CONCRETE PIPE TB = TOP OF BANK T.B.M. = TEMPORARY BENCH MARK ATTACHED TO ANY TREES OR SHRUBS WITHIN PROTECTIVE BARRIERS. = CALCULATED �M) = MEASURED (P) = PLAT Irrigation System Shop Drawing Requirements: The contractor shall supply shop drawings for the irrigation system for the owner's and engineer's approval prior to ordering any equipment. A minimum of the following information shall be included in the submittal. List and catalog information on all equipment to be used: 1. Type of pipe 2. Type of fittings 3. Sprinkler heads 4. Timer 5. Valves (automatic and manual) 6. Wiring 7. Drip lines or devices 8. Rain sensor 9. Well and pump The drawings shall contain the following design data: 1. General piping layout with main line sizes 2. Approximate head / distribution device placement 3. Zone flow demand information 4. Any other pertinent information required to ascertain function of the system proposed. NOTES: 4/16/07 1. A PROTECTIVE BARRIER SHALL BE ERECTED AROUND ALL TREES AND NATIVE 5. NO EXCESS SOIL OR ADDITIONAL FILL, BUILDING MATERIALS, DEBRIS, OR VEGETATION WHICH ARE TO REMAIN PERMANENTLY ON -SITE. SUCH TREES AND LITTER SHALL BE PLACED WITHIN PROTECTIVE BARRIERS. ANY VEGETATION SHALL BE IDENTIFIED BY FLAGGING OR STAKING. DEMOLITION WITHIN THE PROTECTIVE BARRIER SHALL BE ACCOMPLISHED 2. PROTECTIVE BARRIERS ARE TO BE CONSTRUCTED USING NO LESS THAN 2 "x4" BY HAND OPERATED EQUIPMENT. ONCE ALL MATERIAL HAS BEEN LUMBER FOR UPRIGHT POSTS. UPRIGHT POSTS ARE TO BE AT LEAST 4 FEET IN SUCCESSFULLY DISLODGED BY HAND, HEAVY EQUIPMENT WILL BE ALLOWED ON ENTRY INTO BARRIERS IN ORDER TO PUSH DEMOLITION LENGTH WITH A MINIMUM OF ONE FOOT ANCHORED IN GROUND AND THREE FEET MATERIALS BEYOND THE BARRIERS, AFTER WHICH THE BARRIERS MUST ABOVE GROUND. UPRIGHT POSTS ARE TO BE PLACED AT A MAXIMUM DISTANCE BE REINSTALLED. UNDER NO OTHER CIRCUMSTANCES SHALL TRACTORS OF 6 FEET APART. HORIZONTAL RAILS ARE TO BE CONSTRUCTED USING NO LESS OR HEAVY MACHINERY BE ALLOWED TO WORK, PARK, OR LOCATE WITHIN THAN 2 "x4" LUMBER AND SHALL BE SECURELY ATTACHED TO THE TOP OF THE BARRIER AREAS. UPRIGHT POSTS. A PVC -TYPE SAFETY FENCE THE HEIGHT OF THE BARRIER �t SHALL BE ATTACHED TO THE UPRIGHT POSTS, THE TOP RAIL, AND THE GROUND, 6. SIGNS, BUILDING PERMITS, WIRES, (OTHER THAN PROTECTIVE GUY WITH FASTENERS OF EIGHT (8) INCHES APART. BARRIERS SHALL EXTEND AT LEAST WIRES OR OTHER ATTACHMENTS OF ANY KIND SHALL NOT BE (1) FOOT BEYOND THE DRIP LINE OF ALL PROTECTED TREES ON THE PROPERTY ATTACHED TO ANY TREES OR SHRUBS WITHIN PROTECTIVE BARRIERS. AND SHALL BE AT LEAST THREE (3) FEET HIGH. IS PROPOSED TO THE EXISTING IMPERVIOUS SITE CONDITIONS. 1 7. ALL UNDERGROUND UTILITIES SHALL BE ROUTED OUTSIDE THE 3. ALTERNATIVE PROTECTIVE METHODS MAY BE UTILIZED WHEN EXTENDING PROTECTIVE BARRIERS. IF THIS RESULTS IN UNREASONABLE HARDSHIP, PROTECTIVE BARRIERS BEYOND THE DRIP LINE IS NOT FEASIBLE. POSSIBLE A SOIL AUGER SHALL BE USED TO TUNNEL UNDER THE ROOT SYSTEMS. ALTERNATIVES INCLUDING PUMPING CONCRETE FROM A TRUCK THROUGH THE DCO SHALL BE NOTIFIED AND AT HIS OPTION MAY REQUIRE A CONVEYOR PIPES RATHER THAN DRIVING OVER ROOTS, OR BRIDGING ROOT AREAS STAFF MEMBER PRESENT DURING THIS PROCEDURE TO ASSURE WITH STEEL PLATES. ANY PROPOSED ALTERNATIVES MUST BE DESIGNED BY A *-,k\ ADHERENCE TO ALL REQUIREMENTS. TRAINED ARBORIST AND APPROVED BY THE DCO PRIOR TO ISSUANCE OF A DO DATA TABLE OR PERMIT. B. INSTALLATION OF STRUCTURES SUCH AS PROTECTIVE BARRIERS, FENCES, EXISTING POSTS, OR WALLS SHALL NOT DESTROY OR IRREVERSIBLY HARM THE 4. ALL PROTECTIVE BARRIERS SHALL BE IN PLACE AND INSPESTED PRIOR TO ANY ROOT SYSTEMS OF THE PROTECTED TREES. FOOTERS FOR WALLS SITE CLEARING OR DEMOLITION AND SHALL REMAIN IN PLACE UNTIL ALL SHALL END AT THE POINT WHERE LARGER ROOTS ARE ENCOUNTERED, CONSTRUCTION ACTIVITY IS COMPLETED. PROTECTIVE BARRIERS MAY BE AND THE ROOTS SHALL BE BRIDGED. POST HOLES AND TRENCHES TEMPORARILY REMOVED ONLY IF REASONABLE ACCESS INTO THE SITE IS LOCATED CLOSE TO PROTECTED TREES SHALL BE ADJUSTED TO AVOID OBSTRUCTED. REMOVAL OF BARRIERS MUST BE APPROVED AND INSPECTED BY DAMAGE TO MAJOR ROOTS. THE CITY'S ARBORIST PRIOR TO ANY SITE CLEARING OR DEMOLITION. SHOULD 1' BEYOND DRIP LINE 0.52 REMOVAL OF THE BARRIERS RESULT IN STRESS OR DAMAGE TO THE TREE, AS 9. DESTRUCTION OR DISREGARD OF PROTECTIVE BARRIERS MAY REQUIRE DETERMINED BY THE CITY'S ARBORIST, REMOVAL OR REPLACEMENT OF THE TREE THE FULL REPLACEMENT OF THE PROTECTED TREE. MAY BE REQUIRED. PROTECTIVE BARRIERS TREE PROTECTION BARRIER DETAIL NOT TO SCALE FH / I / \ , \ - CONC. WALK - ._---------------- � I NOTE: 20'x20' CITY OF CLEARWATER SIGHT j -� DISTANCE TRIANGLE NO OBJECTS IN THE / / DI DISTANCE SIGHT DISTANCE TRIANGLE MAY EXCEED A / GRATE EL. = 44.62 NOTE: HEIGHT OF 30 MEASURED FROM THE � / Q/ INV. SW. = 41.62 20'x20' CITY OF CLEARWATER SIGHT ADJACENT EDGE OF PAVEMENT. K / �, INV. E. = 40.76 DISTANCE TRIANGLE NO OBJECTS IN THE / Q` SIGHT DISTANCE TRIANGLE MAY EXCEED A T.B.M. #2 EL. = 42.30 - - - - DOME PATTERN SHALL BE IN -LINE EDGE OF S2" 2.35" WITH DIRECTION OF TRAVEL DETECT ABLE �� WARNIN _ I I 0.9 O INTEGRA L DOME O .E� O TRUNCATED DOME N SEE DETAIL ) N O 6� b o O O O O TRUNCATED DOME PLAN VIEW ALL SIDEWALK CURB RAMPS SHALL HAVE DETECTABLE WARNING SURFACES THAT EXTEND THE FULL WIDTH OF THE RAMP AND IN THE DIRECTION OF TRAVEL 24 INCHES (610 mm) FROM THE BACK OF CURB. 0' 5' 10' 20' SCALE IN FEET h / HEIGHT OF 30" MEASURED FROM THE `� -- ADJACENT EDGE OF PAVEMENT. D ST_REE I 7_ / �� -r- % -(60' PUBLIC RIGHT -OF W Y) DETECTABLE MH WARNING SURFACE, RIM EL. = 45.20 I SEE DETAIL 5-- i / INV. E. = 40.39 - ( 'PROPOSED 4' WIDE INV. NW. = 40.15 PROPOSED 6" CONCRETE WALK INV. S. = 40.60 VERTICAL CURB f € INV. SE. = 40.58 0 C! /�- ' -THlS AREA IS TO o \ o = GbRA . _ . - BE SODDED ONLY " \ RADIUS 370.56' ov ;N•. ?''♦ :ARC - 14.81' ------- _ ,I .I 14.81 T.B.1vl. T / CONC. WALK CHORD .�,•:- �� # .> c • ,,• j.. / 0 •4 LJ E •. E 5. t� C. B. - N.2756'32" _ /.. 1 `/ -` 90.00 P / 49.00' - ONE STORY MASONRY BUILDING SECTION 21, TOWNSHIP 29 SOUTH, RANGE 15 EAST NOTE: PROPOSED LANDSCAPE LEGEND ACCENT TREE (2" DIA. - 8' HIGH AT TIME OF PLANTING) ® HIBISCUS TREE (hibiscus roas - sinensis) 1 CHRISTMAS PALM (Veitchii merrillii) 1 ( ) CRAPE MYRTLE (Laegerstroema indica) 2 SHRUBS (INTERIOR PLANTING) 14 " -24" IN HEIGHT - PLANTED EVERY 30 " -36" O.C. RESPECTIVELY (MINIMUM 3 GAL. SIZE) SNOW BUSH (Breynia nivosa) 12 LIRIOPE (Liriope muscari) 10 F� HIBISCUS SHRUB (Hibiscus roso- sinensis) 22 d LIGUSTRUM (Ligustrum japonicum) 22 GROUND COVER BAHIA SOD (Pospalum notatum) NOTE: ALL BUILDING IMPROVEMENTS SHOWN HEREON ARE EXISTING. THIS PLAN INDICATES AN AREA OF PAVEMENT A PAVING R L VA AND AN AREA OF ADDITION REMOVAL RESULTING IN A NET DECREASE IN IMPE RVIOUS AREA. W PROPOSED PAR 0 SHOWS SED KING 0 THIS PLAN ALSO RE- STRIPING AND HANDICAP PARKING SIGNAGE. NOTE: LANDSCAPE AREAS ON -SITE MUST BE COVERED WITH THREE INCHES OF ORGANIC MULCH. NOTE: ALL PAVEMENT STRIPING IS TO BE WHITE, EXCEPT HANDICAP STRIPING (MUST BE STRIPED PER CODE REQUIREMENTS). I .% T A I I t 1 I/ W Z W Q i NOTES: 1. ALL CONCRETE IS TO BE 3,000 P.S.I. MINIMUM. 2. EXPANSION JOINTS ARE TO BE PLACED AT 50' INTERVALS. 3. CONTRACTION JOINTS SHALL BE PLACED AT 10' INTERVALS. 4. TOOL 1/2" RADIUS ALL EXPOSED EDGES. 6" VERTICAL CURB DETAIL NOT TO SCALE DESCRIPTION: Lot 6, Block 16, MAP OF BELLEAIR, according to the plat thereof recorded in Plat Book 1, Page 105, Public Records of Hillsborough County, Florida of which Pinellas County was formerly a part, TOGETHER WITH the East 9 feet of vacated alley abutting subject property on the West. Containing 0.156 acres more or less. 6 i l--- 1 1/2" TYPE S -1 ASPHALT 6" LIMEROCK BASE (SEE PLAN) BASE_ COMPACTED TO 98% OF MAX. �O O •o DENSITY (MODIFIED PROCTOR). SUB -BASV7-DENSITY SUB -BASE COMPACTED TO BEST AVAILABLE / / WITH RUBBER TIRE EQUIPMENT PAVEMENT SECTION NOT TO SCALE 4/16/07 TREE LEGEND 1. ZONING FOR THIS PROPERTY IS IRT (INDUSTRIAL, RESEARCH SYMBOL DESCRIPTION O CMM OAK AND TECHNOLOGY DISTRICT). 4 O 2. TRASH COLLECTION IS BY BLACK BARREL. (2 MAXIMUM) CLEARWATER O RRD 3. UTILITIES ARE EXISTING AND NO CHANGES ARE PROPOSED. ��- �t 4. STORM WATER PLAN IS NOT REQUIRED SINCE NO CHANGE CLEARWATER ❑ CMM OTHER AS NOTED IS PROPOSED TO THE EXISTING IMPERVIOUS SITE CONDITIONS. 11 27 06 PER THE TOPOGRAPHIC ELEVATION CONTOUR LINES OF THIS PARKING BY SIZES AS SHOWN WTS BLACK BORDER PROPERTY ARE SHOWN ON THIS SURVEY. NOTE: ONLY TREES 4" D.B.H. OR LARGER SITE DATA TABLE ACL HAVE EXISTING WHITE BACKGROUND PROPOSED LAND AREA 6,797 SQUARE FEET OR 0.156 ACRES, M.O.L 6.797 SQUARE FEET OR 0.156 ACRES, M.O.L GROSS FLOOR AREA 3,522 SQUARE FEET, M.O.L. BOLLARD 3,522 SQUARE FEET, M.O.L. FLOOR AREA RATIO 0.52 0.52 PARKING SPACES 5 SPACES 0 9 SPACES, INCLUDING 1 HANDICAP SPACE PAVED AREA 2,876 SQUARE FEET, M.O.L. O 2,564 SQUARE FEET, M.O.L. IMPERVIOUS SURFACE RATIO 0.94 0.90 BUILDING HEIGHT 18.30 FEET * 18.30 FEET PROPOSED LANDSCAPE LEGEND ACCENT TREE (2" DIA. - 8' HIGH AT TIME OF PLANTING) ® HIBISCUS TREE (hibiscus roas - sinensis) 1 CHRISTMAS PALM (Veitchii merrillii) 1 ( ) CRAPE MYRTLE (Laegerstroema indica) 2 SHRUBS (INTERIOR PLANTING) 14 " -24" IN HEIGHT - PLANTED EVERY 30 " -36" O.C. RESPECTIVELY (MINIMUM 3 GAL. SIZE) SNOW BUSH (Breynia nivosa) 12 LIRIOPE (Liriope muscari) 10 F� HIBISCUS SHRUB (Hibiscus roso- sinensis) 22 d LIGUSTRUM (Ligustrum japonicum) 22 GROUND COVER BAHIA SOD (Pospalum notatum) NOTE: ALL BUILDING IMPROVEMENTS SHOWN HEREON ARE EXISTING. THIS PLAN INDICATES AN AREA OF PAVEMENT A PAVING R L VA AND AN AREA OF ADDITION REMOVAL RESULTING IN A NET DECREASE IN IMPE RVIOUS AREA. W PROPOSED PAR 0 SHOWS SED KING 0 THIS PLAN ALSO RE- STRIPING AND HANDICAP PARKING SIGNAGE. NOTE: LANDSCAPE AREAS ON -SITE MUST BE COVERED WITH THREE INCHES OF ORGANIC MULCH. NOTE: ALL PAVEMENT STRIPING IS TO BE WHITE, EXCEPT HANDICAP STRIPING (MUST BE STRIPED PER CODE REQUIREMENTS). I .% T A I I t 1 I/ W Z W Q i NOTES: 1. ALL CONCRETE IS TO BE 3,000 P.S.I. MINIMUM. 2. EXPANSION JOINTS ARE TO BE PLACED AT 50' INTERVALS. 3. CONTRACTION JOINTS SHALL BE PLACED AT 10' INTERVALS. 4. TOOL 1/2" RADIUS ALL EXPOSED EDGES. 6" VERTICAL CURB DETAIL NOT TO SCALE DESCRIPTION: Lot 6, Block 16, MAP OF BELLEAIR, according to the plat thereof recorded in Plat Book 1, Page 105, Public Records of Hillsborough County, Florida of which Pinellas County was formerly a part, TOGETHER WITH the East 9 feet of vacated alley abutting subject property on the West. Containing 0.156 acres more or less. 6 i l--- 1 1/2" TYPE S -1 ASPHALT 6" LIMEROCK BASE (SEE PLAN) BASE_ COMPACTED TO 98% OF MAX. �O O •o DENSITY (MODIFIED PROCTOR). SUB -BASV7-DENSITY SUB -BASE COMPACTED TO BEST AVAILABLE / / WITH RUBBER TIRE EQUIPMENT PAVEMENT SECTION NOT TO SCALE l CITY OFCLE>a WATER P NNINC DE T.' f� BY -� DA E FLS Zoa(o - 0905$ LADSCA PA AID5 .I... ;.+ p � 'DSCA!'t iRi t'� R�9U3p =L FOR I, lOx iSLATS 50% comaq-e Wish Iv, - I do , A!,N CHANGES *a SPECIES, SpEC1I:K:AIONS, OR DESIGN WTHOUT ,HE CONSENT OF THE �-IILNNNING DIRECTOR ENDEPS r'Lp�g roaRr)\,nl VOID. AL AREAS 5IF1 ctrl STRE':T PAVENItN7 AND ? ARKING LOT 10 ?t TURFED OR R;C-:C-IVE 07I ER 1ANDSCA °1N; 7RFATMENT. All IANM^�COVN K-- r 10 Co t�h+~•pec•}�n'e� are ^tangy 8 "x2' -6" CONCRETE MASS. FINISH TOP OF MASS LEVEL WITH A SLIGHT RAISED WASH APPROXIMATELY 1/2- ABOVE LEVEL OF TURF /SOD. ST ANDARD PRE - PAINTED DISABLED PARKING a, SIGN ON 1/8" THICK SHEET ALUMINUM Z It oI 0 t 2" HOT DIPPED GALVANIZED STANDARD WEIGHT STEEL PIPE vi z IIIIG'll�l (o - =1fr t N u _ <O 4 -8- -4 HANDICAP SIGN DETAIL NOT TO SCALE R5 -1 W/R 30" x 30" DO NOT ENTER SIGN NOT TO SCALE THIS IS NOT A BOUNDARY SURVEY 5 4/16/07 TREE LEGEND PER 1._D.. SYMBOL DESCRIPTION O CMM OAK 'S1... 4 O PINE CITY OF CLEARWATER O RRD PALM W BORDER HITS ��- �t CITRUS do SYMBOL CLEARWATER ❑ CMM OTHER AS NOTED BLUE BACKGROUND 11 27 06 PER CITY OF PARKING BY SIZES AS SHOWN WTS BLACK BORDER DISABLED NOTE: ONLY TREES 4" D.B.H. OR LARGER &LETTERS PERMIT ACL HAVE BEEN LOCATED AND SHOWN. WHITE BACKGROUND ONLY DATE SYMBOL LEGEND BLACK BORDER $255 FINE �' w BOLLARD do LETTERS F.S. 318.14 LIGHT POLE WHITE BACKGROUND 0 MANHOLE O PHONE SERVICE PEDESTAL ALL LETTERS * POWER POLE 1" SERIES "C" a SIGN 0 TRANSFORMER 0 WATER METER 7T_ATr l CITY OFCLE>a WATER P NNINC DE T.' f� BY -� DA E FLS Zoa(o - 0905$ LADSCA PA AID5 .I... ;.+ p � 'DSCA!'t iRi t'� R�9U3p =L FOR I, lOx iSLATS 50% comaq-e Wish Iv, - I do , A!,N CHANGES *a SPECIES, SpEC1I:K:AIONS, OR DESIGN WTHOUT ,HE CONSENT OF THE �-IILNNNING DIRECTOR ENDEPS r'Lp�g roaRr)\,nl VOID. AL AREAS 5IF1 ctrl STRE':T PAVENItN7 AND ? ARKING LOT 10 ?t TURFED OR R;C-:C-IVE 07I ER 1ANDSCA °1N; 7RFATMENT. All IANM^�COVN K-- r 10 Co t�h+~•pec•}�n'e� are ^tangy 8 "x2' -6" CONCRETE MASS. FINISH TOP OF MASS LEVEL WITH A SLIGHT RAISED WASH APPROXIMATELY 1/2- ABOVE LEVEL OF TURF /SOD. ST ANDARD PRE - PAINTED DISABLED PARKING a, SIGN ON 1/8" THICK SHEET ALUMINUM Z It oI 0 t 2" HOT DIPPED GALVANIZED STANDARD WEIGHT STEEL PIPE vi z IIIIG'll�l (o - =1fr t N u _ <O 4 -8- -4 HANDICAP SIGN DETAIL NOT TO SCALE R5 -1 W/R 30" x 30" DO NOT ENTER SIGN NOT TO SCALE THIS IS NOT A BOUNDARY SURVEY 5 4/16/07 PER CITY OF CLEARWATER REQUIREMENTS CMM I %*IC 'S1... 4 2/28/07 PER CITY OF CLEARWATER REQUIREMENTS RRD %W dS6r 3 1/23/07 PER CITY OF CLEARWATER REQUIREMENTS CMM or 'SLR 2 11 27 06 PER CITY OF CLEARWATER REQUEST WTS %or 9.- 1 2 22 06 ADDED ADDITIONAL LAND PER OWNERS DIRECTION ACL W sip No.I `ITY OF CLEARWATER DATE REVISIONS I DRN.ICKD.IAPP �' w SITE PLAN, SPECIAL PURPOSE SURVEY AND TREE SURVEY JOB No. 32114 SEGIHAY OF TAMPA BAY D STKEIET MV1 VK5 __....- ,. SITE PLAN, SPECIAL PURPOSE SURVAIDIITREE SUR) co CITY OF CLEARWATER PINELLAS COUNTY '�. c) PREPARED FOR: DATE: 1 -16 -06 APPROVED BYJ 4 i'�r ±'fir = it CZ ll J U EGWAY OF TAMPA BAY DES.: T.G. Radcliffe ;t E /o STEPHEN G. WATTS, ESQ. DRN.: KB, CMM - !` �� J V E D 606 DRUID ROAD EAST CKD.: RO } -_ CLEARWATER, FLORIDA 33756 SCALE: 1" = 10' S. AN " E� • V l�S� � am APR, 2 0 2007 11 Phone: (727) 461 -3232 FL 'ENGINEER'$ � LICENS - 8508 Fax: (727) 441 -0048 JOB No. 32142 FL SURVEYOR ^8, NtAI*P No. LS to a LLOVERAS BAUR & STEVENS �S DEVELOP ENT ® o N E? G H B C P 80 0 0 s E 3 V I C E S ENGINEERS 0 0 `ITY OF CLEARWATER #LB 0000208 (727) 784-3965 Fax: (727) 784 -8153 29228 U.S. HIGHWAY 19 N. CLEARWATER, FLORIDA 337611 a �' w SITE PLAN, SPECIAL PURPOSE SURVEY AND TREE SURVEY JOB No. 32114 o co "