Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
620 DRUID RD
® r MEET AND MATCH -- - • EXISTING PAVEMENT RELOCATE GUY WIRE 3 w S. 89°0555 E 176, 59' � 5- LIVE OAK -� SS- RFD TIP GRAPHIC SCALE : :: : :. On �4 0 15 30 60 IN FEET CONST. Inc RAMP m 1 = _ ..= � ,A 30 ft. a c h FDOT INDEX No 304 ^• Q CONST. 6' CHAIN LINK FENCE Zz^ h CHANGES IN SPECIES ; SPECTICA 10 + D I GN WI1'HdUT' T11E CO `• i Oa' TITE DI r=C E D A T A VIR®IiY1ENTAL i4IAN *M1ENT RENDERS PLAIN PFFROaOSED BUILDING - f APPROVAL VOID. EXISTING ZONING CG, OL N ' - EXISTING LAND USE VACANT PROPOSED LAND USE UTILITY SUB STATION CONSTRUCT I MAXIMUM GUIDING HEIGHT 35 FT, HVAC PAD j ` O PROPOSED BUILDING HEIGHT 12 FT. R� CONST. 6.25'x5 TRANSFORMER PAD gGROSS SITE AREA 48,056 S.F. f � ` ' 0 �..'fVL FLOOR AREA 432 S.F. x1 CONST. 20'8'' ens 16" GENERATOR PAD _ _ ., + `� Q F.A.R. PROVIDED 432/48,056 = 0.009 a N. 89 °0505`41! 744.00', ,. 1? ICONST, 6' PT SHADOW _ PAVEMENT PROVIDED 2,180. S.F. BOX FENCE TOTAL IMPERVIOUS 3,259 S.F. LANDSCAPE' & OPEN SPACE PRVIDED 44,797 S.F. O •stalled REQUIRED SETBACKS el oat be op m ecion. STREET R W 25' 'ALL landscap in mfrior O insp SIDE 10' per approved p axi fees are mandatory. REAR 10' -geiuspecuon PARKING REQUIRED 2 ?: PARKING PROVIDED 2 HANDICAPPED PARKING PROVIDED 1 STANDARD PARKING REQUIRED 1 Q rt ^ h (GENERAL LC�C���1® �i . F.C.M. - Found Concrete Monument F.I.P. - Found Iron Pipe F.I.R. - Found Iron Rod : • F.P.K. - Found P.K. Nall S.I.R. - Set 112" iron Rod (LB #021) a S.P.K. - Set P.K. Nail (LB #021) N. C. F. S. No Corner Found or Set N. C. - No Identification Cap . St. t9' Q E.P. - Electric Pole _. - ;�. • . N. 88 °5532 "!!! _ - e U.P. Utility Po! - L. P. Light Pole SCAPE d - -E -- - Electric Line i.AND P5 CA - -T -- - Telephone Line _. -. • ;' A??�R ®� ° • ° ° • - -CTV -- - Cable Television Line • ° ° °., ; F - -- Guy Wire &Anchor bate° •� .°•° _ - • p . - -W -- Water Line �i % Q .14'.: . • . • • ' - epament M.H. - Manhole _ __ "B _ . v �- publicWoC s office W V Water Valve e j''pVl1DC1m6n F.H. - Fire Hydrant W. M. Water Meter (R.) - Record Dimension (M.) - Field Measure (C.) - Calculated PO LAHT LISA C 0 - Clean Out SYM QTY BOTANICAL NAME COMMON NAME SPECIFICATION — REMARKS TREES AND PALMS QV 5 Quercus virginiona LIVE OAK 10' -12' HTx 5'— 6' SPR., 3" CAL., 30 GAL. OR B &B, SEE PLAN SHRUBS AND GROUNDCOVERS PF 59 Photinia froseri 'Red Tip' RED TIP PHOTINIA -24 30" HT.x 24" SPR., 3 GAL., 30" OC. SOD TURNBUCKLE Paspolum notatum BAHIA SOD SOLID SOD ROLLED AND BUTTED 0 S. V.' - Sanitary Sewer Valve R.C.P. - Reinforced Concrete Pipe C.M.P. - Corrugated Metal Pipe G.T.I. - Grate Top Inlet C.I.P. - Cast Iron Pipe . M.E.S. - Mitered End Section R/W -. Right of Way C.L. - Chain Link 6-1/2" GALV. - Oak Tree TURNBUCKLE CLIENT PROJECT NAME REVISIONS TIME WARNER COMMUNICATIONS 11500 NINTH STREET NORTH ST. PETERSBURG, FL 33716 (813) 576 -4123 TIME WARNER COMMUNICATIONS HUB "Q" LANDSCAPE PLAN SEC.— TYJP. — S..RNG. —E. No. DESCRIPTION Ga© a'A �J. Wamey. su)16 PLANT SPACING AS PER PLAN 3" OF SPECIFIED MULCH —n W WRITTEN 7PREPARE BED N.- AS PER SPECIFICATION SPECIFIED 1+ Z!I AROUND. PLANTING MIX ALL REMOVE TAMP TO POCKETS AIR UNDISTURBED SUBGRADE 2X BALL DIA. NOTES: • PLANT SO THAT TOP OF ROOT BALL IS EVEN WITH THE FINISHED GRADE. SHURU D G°PLANTIHIG DETAIL N.T.S. NOTES: 1. NO TREE SHALL BE REMOVED UNLESS SPECIFICALLY TAGGED FOR REMOVAL BY THE ENGINEER. 2. THE CONTRACTOR SHALL TAKE SPECIAL CARE NOT TO DAMAGE ANY TREES THAT ARE TO REMAIN. 3. ROOTS GREATER THAN 1" DIAM. SHALL NOT BE CUT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 4. ROOTS OF 1" DIAM. OR LARGER THAT NEED TO BE CUT SHALL BE -CUT NEATLY. 5. STOCKPILED MATERIALS OR UNNECESSARY VEHICULAR TRAFFIC SHALL NOT BE ALLOWED OVER ANY TREE ROOT SYSTEM. 6. TYPE 'A' BARRIER OR TYPE 'B' BARRIER SHALL BE CONSTRUCTED WHEN CALLED FOR ON PLANS OR AS DIRECTED BY THE ENGINEER. BARRIERS SHALL BE MAINTAINED IN PLACE UNTIL REMOVAL IS DIRECTED BY THE ENGINEER. BEFORE PERMIT: 1. BARRIERS ARE TO BE ERECTED AROUND ALL TREES 4" DBH AND GREATER TO REMAIN. THIS MUST BE DONE BEFORE CONSTRUCTION, GRADING, OR BEFORE ANY TREES ARE REMOVED. 2. TREES 4" DBH AND GREATER THAT ARE LOCATED WITHIN 10' OF THE LOT UNDER CONSTRUCTION SHALL ALSO BE PROTECTED BY A BARRICADE. TREE oAHORICADG DETAIL ►>~03 LANDSCAPE MOTES:. TRUNK f � C` l 1�0 l GUYING PLAN N.T.S. 1" DiAM. RUBBER HOSE DOUBLE STRAND TWISTED WIRE #12 GA. (3 GUY WIRES PER TREE AT 120' INTERVALS 3" OF SPECIFIED MULCH EXTENDED BEYOND SAUCER. KEEP MULCH AT LEAST 3" FROM TREE TRUNK 6" SAUCER 0 SPREAD S6- IIt jjjjl��- TINA-i h"it" NO dOCS TREE WRAPPING FASTENED NEAR TOP & BOTTOM WITH CORD FLAG W/ BANNER GUARD S.S. 2 x 6-1/2" GALV. Q TURNBUCKLE < 0 J v � o x W Y lL z U a 113• 2 "x2 "x36" 12" MIN. SPECIFIED I I- ____= PRESSURE TREATED PLANTING MIX ALL �) _ _I STAKES - NOTCH TO AROUND. WATER & I I HOLD WiRE. TOP OF TAMP TO REMOVE I i I I; III • • . III 1 GRADE SET BELOW AIR POCKETS — — 11= - REMOVE TOP 1/3 OF BURLAP FROM BALL 2X BALL DIA, UNDISTURBED SUBGRADE NOTES: PLANT SO THAT TOP OF ROOT BALL IS EVEN WITH THE FINISHED GRADE. BOTTOM OF ROOT BALL SHALL BE SEATED DIRECTLY ON UNDISTURBED SUBGRADE. • STAKE ABOVE FiRST STRONG BRANCHES OR AS NECESSARY FOR FIRM SUPPORT. • FLAG GUYING WIRES WITH BANNER GUARD S.S. 2 OR APPROVED EQUAL. �r��I� r�� A M��i�0 nr�� n OH �Il�� Wor�rs N.T.S. INSTALLATION SPECIFICATIONS: + NOTE: EITHER TYPE 'A' BARRICADE (WOOD) OR TYPE 'B' BARRICADE (RIBBON OR APPROVED EQUAL) MAY BE USED. 1. MINIMUM RADIUS TO BE PROTECTED: PINES: DRIPLINE OR 6', WHICHEVER IS GREATER. HARDWOODS AND ALL OTHERS: 2/3 OF THE DRIPLINE OR 6', WHICHEVER IS GREATER. 2. METHOD OF ERECTION: (SEE DIAGRAM) A. MINIMUM HEIGHT OF UPRIGHTS SHALL BE 3' AND NO LESS THAN 2 "x2" LUMBER. I B. UPRIGHTS SHALL HAVE HORIZONTAL RIBBONING OR N .APPROVED EQUAL AT X t`x2` THE TOP AND 12" BELOW ell THE TOP. (TYPE 'B' BARRIER) xz C. UPRIGHTS SHALL BE SPACED AT NO MORE THAN 4' -5' INTERVALS. 2/3 DRIPLINE (HARDWOODS) D. HORIZONTAL MEMBERS SHALL FULL DRIPLINE (PINES) BE OF NO LESS THAN 1%2" EXAMPLE OF TYPE 'A' WOOD BARRIER LUMBER. (TYPE 'A' BARRIER) 1. ALL GREEN SPACE AREAS NOT SPECIFIED OTHERWISE WILL BE SODDED WITH BAHIA SOD - SAND GROWN. LAYER SOLID AND ROLL. 2. A FULLY AUTOMATIC IRRIGATION SYSTEM, PROVIDING 100% COVERAGE OF ALL GREEN SPACES IF REQUIRED, SHALL BE MAINTAINED. NO CONTROL VALVES OR MAINLINE SHALL BE LOCATED IN R.O.W., ALL IRRIGATION HEADS WITHIN R.O.W. SHALL BE INSTALLED ON FUNNY PIPE OR EQUAL. COORDINATE WITH G.C. FOR INSTALLATION OF CONTROLLER. 3. SEE SURVEY FOR ADDITIONAL INFORMATION REGARDING THIS SITE. 4. ALL TREES WHICH FALL WITH IN SODDED AREA SHALL BE MULCHED AS FOLLOWED: PROPOSED LANDSCAPE TREES - SHALL HAVE A 4' DIAMETER MULCHED RING. PROPOSED PALMS AND CONIFERS TREES - SHALL HAVE A 3' DIAMETER MULCHED RING. EXISTING TREES - SHALL HAVE A 4' WIDE MULCHED RING ADDED AT THE BASE OF THE TREE. 5. ANY AREA DISTURBED OUTSIDE LIMITS OF SOD (PROPERTY LINE) SHALL BE SODDED WITH BAHIA SOD. .George F. Young, Inc. ARCHITECTURE ■ ENGINEERING ■ENVIRONMENTAL LANDSCAPE ARCHITECTURE■ PLANNING ■ SURVEYING ST. PETERSBURG ■ TAMPA ■ BRADENTON ■ NEW PORT RICHEY ■GAINESVILLE RESPONSIBLE OFFICE: 299 9th Street North St. Petersburg FL 33701 -0683 Tel.: (813) 822 -4317 Fax: (813) 822 -2919 Since 1919 DESIGNED: DCP IAPPROVED DATE: DATE BY ( CHECKED: RRL SCALE: 1 = �4a_ JUN o 2 1997 CENTRAL PERMITTING CITY OF CLEARWATER SHEE1 QA • 4 . i _I gPT'R:UrA FLA 41 1; T•• 550 I ilh► ��pR�ti`i�� �` JOB No. 9711003900 c� o• i a x a r m x z z w 3 0 w z a w z 0 2 0 a n m a 0 N 0 0 W a-