FLD2012-11026 �. . _ � � �������,� COMMUNITY DEVELOPMENT BOARD PLANNING AND DEVELOPMENT DEPARTMENT � STAFF REPORT MEETING DATE: 1vlarch 19, 2013 AGENDA ITEM: �.1. CAS E: FLD2012-11026 REQUEST: Flexible Development approval to permit a 3,010 square foot Automobile Service Station use in the Commercial(C) District with lot area of 34,155 square feet, lot widths of 150 feet (Sunset Point Road) and 160 feet (Hercules Avenue), front (south) setbacks of 25 feet (to canopy) and 15 feet (to pavement), a front (southeast) setback of 14.57 feet (to pavement), front (east) setbacks of 64.73 feet (to building) and 10.44 feet (to pavement), side (west) setbacks of 44.18 feet (to building) and 4.69 (to pavement), side (north) setbacks of 11.45 feet (to building) and 18 feet (to pavement), a building height of 21.25 feet, and 12 off-street parking spaces as a Comprehensive Infill Redevelopment Project pursuant to Community Development Code Section 2-704.E., as well as reductions to the interior landscape island area to 731 square feet (3.5%) where 2,087 square feet(10%) is required, and a reduction of the foundation landscaping to zero feet where five feet is required as a Comprehensive Landscape Program pursuant to Community Development Code Section 3-1202.G. GENERAL DATA: Agent........................... Elizabeth Abernethy; Stantec Consulting Applicant/Owner............. S & I Ventures LLC. LoCation.......................... 1990 Sunset Point Road; the northwest corner of Sunset Point Rd. and N. Hercules Ave. Property Size.................... 0.78 Acres Future Land Use Plan...... Commercial General(CG) Zoning.......................... Commercial (C)District Special Area Plan.............. N/A Adjacent Zoning.... North: Commercial (C)District South: Commercial (C)District East: Commercial (C)District West: Commercial(C)District Existing Land Use............. Automobile Service Station(abandoned) Proposed Land Use......... Automobile Service Station (3,010 square feet) ;r' ��� ' ' l �;,' ;� � �1 ` � � ` �r,,, � e�•�,, ��� 1 �=� � � .� ��,� x-� -� �: �"'�- = �., , , f.. � � ;� : �k - n+� �'` � ` �� ��' r-� � � ' � � � F`�� .e�,�:` .� , sfg,y �� a a � � ":. ��� • , �L�z -: � � , • ,:_� ���.,' �� dlk , . �, � , r � . `, �� ,. � ��. w� � �, � �:,..; . � �, ,�; w'"� + :� + — . y � � � a _,� _� �h.��� y�•� -, �JPI�=-T�Jl�`ll'i�J ,.��` e� " '"�' ,�, *� . • ,�,_, A �' m � it. <, > � . . , �: . ....,�, , ._ ..___.._. .; .: x' $� . .:. � ��� h ... .-t : � �`9 , :, .. � : . . r C���l t"►�Lt,�Level II Flexible Develo ment A lication Review pLn�m�G&nEVeLOrn�Nr P PP DEVELOPMENT REVIEW DIVISION ��✓-�M/'�N�''�. . � � � � � �� ANALYSIS: � � � � BUFORD � � � O y � F � O 3 Site Location and Existing Conditions: �° s g o � ;~..:..:` : � � GAVLE �Q�� '.�..::lftob: The 0.78-acre subject property is located at the MONTCIAIR N Ro --•- northwest corner of Sunset Point Road and N. �:�o �o���FFE DR N � 9 z BE h � W � 5��,,. Hercules Avenue. The subject property is E ° ' ;�� _ oak � p g comprised of one parcel with approximately 150 Ba� " � t°" � °R = N S�" TREE ° z 2 PROJECT N 7 SITE � feet of frontage along Sunset Point Road and = Q�a���a� _ approximately 160 feet of frontage along N. ' �, HASTINGS �N � � ` Hercules Avenue. The subject property is ZOIIE'.0 J SUNSET POINT RD Commercial (C) District. The intersection of ;:: ; S��=et��o�e�� Sunset Point and N. Hercules Avenue is , D ; _ characterized b commercial uses. The sub�ect site '� - ,, �' ` Y J , is in the center of the Commercial district at this � 1 ' '`s . intersection. The C District , L A P OC TION MA extends to the north, south, east, and west, .� , however, beyond the initial adjacent properties the - e^RR�r�TOI�,� �—� -� a � . . � . , _ _ � . : �_ -_ � � - - - zonin is Office O to the north O en S ace � ` =�T`; ` g � ) � p p ��� I � I, /Recreation (OS/R) to the east, Institutional (I) to ,.� ,.g 'u osix the west and further to the west is Low Medium ;� o = Density Residential (LMDR). To the south, the ,: ° 'p "" L`�rD land is zoned Industrial Research and Technology IA 1 "" 2 (IRT) and to the southeast is Medium Density —.,'""""� � °� Residential (MDR). The subject property is ; t � ; �� ; W currentl y develo ped with 1 467 s quare foot of --- -� -- � SUNSETPO/NTRD � � Automobile Service Station use that was annexed ----- —^� � into the City in 2012. The building is currently � - '�'������°�°R�a��m��s� � vacant. a����x� �xxx�RR��'R�R rn I Development Proposal: ZONING MAP The development proposal is to demolish the 6 � „ GTO n �sas q� 4 ; existing structure and build a new 3,010 square ,s �s q ^� ; _ °° •r foot Automobile Service Station. The Automobile - - - � P .g Service Station definition includes facilities for °� �� � I� �=°� < lubricating, minor repairs or vehicle service, Nursing '°"L'�� � however no repair or service is proposed. A total of 3,. Home '�'r—� � six gas pumps are proposed, as well as twelve �° ��o�nt parking spaces and landscaping improvements. � wm s��e �u omp I� rv "� , - The development proposal's compliance with the � �SeCWICe' } � SUNSEiPOMTRD various development standards of the Community f� � ' _ Development Code (CDC) is discussed below. and�er�ic " � aR R R °R q '„R � ��� I, e RR� RR R R8 R'RR^=^^ E I ^ Floor Area Ratio (F.A.R.� Pursuant to Section 2- ' ,.m EXISTING SURROUNDING USES MAP 701.1,CDC, and the Countywide Plan Rules the maximum allowable F.A.R. within the CG Future Land Use Plan Category is 0.55; therefore the Community Development Board—March 19,2013 FLD2012-1 1026—Page 1 � � C�btt�1`1'�L��Level II Flexible Develo ment lication Review PLArrx�G&DEV�LOPMErrr P APP DEVELOPMENT REVIEW DIVISION u ._. . . 'k"�.k.,..._.�:. . .. 0.78 acre subject property is permitted a maximum of 18,791 square feet of gross floor area. The development proposal is for only 3,010 square feet (0.088 FAR); thus the proposal is in compliance with the above requirement. Impervious Surface Ratio (ISR� Pursuant to CDC Section 2-701.1, and the Countywide Plan Rules the maximum allowable ISR is 0.90. The proposal is to maintain the existing impervious surface ratio of 0.77, which is consistent with the Code. Minimum Lot Area and Width: Pursuant to CDC Table 2-704, there is no minimum required lot area or lot width for a Comprehensive Infill Redevelopment Project. However, for a point of comparison, pursuant to CDC Table 2-703, Flexible Standard Development Standards, the minimum lot area for Automobile Service Station is 10,000 square feet. The lot area is 34,155 square feet. Pursuant to the same Table, the minimum lot width for Automobile Service Station is 100 feet. The lot width along Sunset Point Road is 150 feet and the frontage along N. Hercules Avenue is 160 feet. The proposal meets or exceeds these Code provisions. Minimum Setbacks: Pursuant to CDC Table 2-704, there are no minimum required setbacks for a Comprehensive Infill Redevelopment Project. However, for a point of comparison, pursuant to CDC Table 2-703, Flexible Standard Development Standards, the minimum front setback for Automobile Service Station uses is 25 feet (to building) and the minimum side setback is 10 feet (to building). Parking lots may be located at the otherwise required landscape buffer width irrespective of setback requirements. The required setbacks for the subject site with regard to parking are 15 feet (south, southeast, and east) and five feet (north and west). Parking is not proposed along the north property line. The proposed building would have a front (south) setback of 25 feet (to canopy) and 15 feet (to pavement), a front (southeast) setback of 14.57 feet (to pavement), front (east) setbacks of 64.73 feet (to building) and 10.44 feet (to pavement), side (west) setbacks of 44.18 feet (to building) and 4.69 (to pavement), side (north) setbacks of 11.45 feet (to building) and 18 feet (to pavement). The existing setbacks do not meet the minimum standard development requirements of Code; however the proposed setbacks are requested through a Comprehensive Infill Redevelopment and meet the code to the maximum extent practicable and are supportable. Maximum Buildin�,Hei� Pursuant to CDC Table 2-704, the maximum building height within the C District is 25 feet. The proposed building measures 21.25 feet (to top of flat roo fl which is in compliance with the above requirement. Minimum Off-Street Parkin�: Pursuant to the CDC Table 2-704, the required parking for Automobile Service Station use within the C District is five parking spaces per thousand square feet of gross floor area. The development proposal provides for 12 off-street parking spaces, which equates to 3.9/1,000 GFA. The applicant has submitted a Parking Demand Study that analyzed the parking demand for similar stores on similar roadways and the justification has been determined to be satisfactory. Solid Waste Containers and Mechanical Equipment: Pursuant to CDC Section 3-201.D.1, all solid waste containers, recycling or trash handling areas and outside mechanical equipment shall Community Development Board—March 19,2013 FLD2012-11026—Page 2 � Cl��T��6e1 Level II Flexible Develo ment A plication Review PL^rrr��c&DEVEiorMENT p P DEVELOPMENT REVIEW DIVISION J . .. �.,.. ... . be completely screened from view from public streets and abutting properties by a fence, gate, wall, mounds of earth, or vegetation. The proposed dumpster will be located within an enclosure that is located behind the primary building. The enclosure will be constructed of like materials and finishes to that of the building including stucco and stone. A lift station is proposed on the north side of the building and is proposed to be screened with a black vinyl chain link fence. Chain link is not sufficient to screen a lift station and a condition of approval has been added that the fence material be revised to be consistent with the dumpster enclosure and building fa�ade. Sight Visibility Triangles: Pursuant to CDC Section 3-904.A, to minimize hazards at the proposed driveways on Sunset Point Road and N. Hercules Avenue, no structures or landscaping may be installed which will obstruct views at a level between 30 inches above grade and eight feet above grade within 20-foot sight visibility triangles. The proposal meets this requirement. Landscapin�: Pursuant to CDC Section 3-1202.D, the required perimeter buffers are 15 feet in width along the fronts (south, southeast, and east) and five feet in width along the sides (north and west). The proposal includes the maximum practicable landscaping buffers and includes a 15 foot landscape buffer along Sunset Point Road, a 14.57 wide landscape buffer at the southeast corner and a 10.44 foot wide buffer along N. Hercules Avenue. These buffers will have shade trees, accent trees, and palms. These front buffers will also have a continuous hedge, shrubs, and ground cover. The side (west) buffer will have shade tolerant accent trees. This side buffer is too narrow for shade trees and there are existing shade trees on the adjacent property with large established canopies that extend onto the subject site. Additional shade trees in the buffer would be inappropriate for tree development. The side (north) buffer will have a continuous hedge, ground cover and accent trees. This buffer is also too narrow for shade trees and there are also existing shade trees on the adjacent property with established canopies. At the northwest corner a stormwater pond is proposed. This is pond is behind the building and is not in the five foot landscape buffers, however it is proposed to have landscaping on the top of bank. Ground cover and a shade tree are proposed in the storm water area. This additional landscaping around the pond is not required. The interior landscaping required is ten percent of the total vehicular use area which would require 2,087 square feet of interior landscaping. A total of 731 square feet of interior landscaping is provided. The site cannot increase the interior landscaping without further reducing the parking. The required five foot foundation landscaping is not being provided on the south and east facades facing the adjacent right-of-way. The site is proposing the maximum practical landscaping improvements and is focusing landscaping improvements in those area that are most visible; the front buffers. In addition, the proposal will provide native tree and shrub species as encouraged in the CDC. The provided trees will also be a larger caliper than required by code. While smaller trees establish faster the larger trees are proposed to increase aesthetic appeal. No turf is proposed in the buffers or interior landscape area and this will reduce the water demand for irrigation. The proposed landscaping will be a significant improvement, is the maximum practicable, and is supportable. Utilities: Pursuant to CDC Section 3-912, all utilities, including individual distribution lines, shall be installed underground unless such undergrounding is not practicable. It is attached as a condition of approval that prior to the issuance of certificate of occupancy all on-site utility Community Development Board—March 19,2013 FLD2012-11026—Page 3 � C��1 1Y�L�1 Level II Flexible Development Application Review PLANNING&DEVELOPMENT DEVELOPMENT REV�W DIVISION u . . ...�:�...�>..�.. ,. facilities, whether they be existing or proposed, are to be placed underground as part of the redevelopment of the site. Si�na�e: The proposal does not include any signage at this time. Any signage, if and/or when proposed, must meet Code requirements. Comprehensive Plan: The proposal is supported by various Goals, Objectives and/or Policies of the City's Comprehensive Plan as follows: Future Land Use Plan Element Policy A.3.2 Objective — All development or redevelopment initiatives within the City of Clearwater shall meet the minimum landscaping/ tree protection standards of the Community Development Code in order to promote the preservation of existing tree canopies, the expansion of that canopy, and the overall quality of development within the City. The proposal includes a Comprehensive Landscape Program due to the reduction of a buffers, interior landscaping, and foundation landscaping. However the proposal includes a majority of compliant buffer widths, additional shade trees, accent trees, palms, hedges, shrubs, and ground cover and meets the spirit of this objective to the maximum extent practicable. Objective A.6.4 — Due to the built-out character of the city of Clearwater, compact urban development within the urban service area shall be promoted through application of the Clearwater Communiry Development Code. The proposal addresses this Objective through the use of the Comprehensive Infill Redevelopment Project as part of a Flexible Development application for the reuse of an existing building and site which, without the requested deviations from Code would have its potential use severely limited. Community Development Code: The proposal is supported by the general purpose, intent and basic planning objectives of this Code as follows: Section 1-103.B.1. Allowing prope�ry owners to enhance the value of their property through innovative and creative redevelopment. The property owners will make improvements to the site including new building structure with improved fa�ade treatments and landscaping enhancements. The existing building and site were previously used for an automobile service station. The proposal will re-establish that use within a new building and improved site. Section 1-103.B.2. Ensuring that development and redevelopment will not have a negative impact on the value of surrounding properties and wherever practicable promoting development and redevelopment which will enhance the value of surrounding properties. Surrounding properties to the south, east and west have been developed with a variety of non- residential uses including retail sales and services, fast-food restaurant, and automobile service station. These properties have been similarly developed with regard to setbacks (to pavement) and landscaping as the subject property. Section 1-103.B.3. Strengthening the city's economy and increasing its tax base as a whole. Community Development Board—March 19,2013 FLD2012-11026—Page 4 Y C�LL11 1'1'�Ll.l Level II Flexible DevelopmentApplication Review PLANNING&DEVELOPMENT DEVELOPMENT REVIEW DIVISION y ... . . �.:..N�"..:"..-. . . The existing building is vacant. The proposal will re-establish a use for which the site was used, while bringing a needed service to the neighborhood and the City of Clearwater as a whole. Section 1-103.E.3. Protect and conserve the value of land throughout the ciry and the value of buildings and improvements upon the land, and minimize the conflicts among the uses of land and buildings The proposed use is not anticipated to have any conflict with the surrounding uses of land. The building was previously used for an automobile service station. The proposal will re-establish that use within a new building and improved site. Genera�urpose and Intent of the Commercial ZoninQ�District (Section 2-701): The intent and purpose of the Commercial District is to provide the citizens of the City of Clearwater with convenient access to goods and services throughout the city without adversely impacting the integrity of residential neighborhoods, diminishing the scenic quality of the city or negatively impacting the safe and efficient movement of people and things within the City of Clearwater. The proposal will provide a needed use conveniently located at an intersection. The surrounding uses are Commercial and the use will not negatively affect residential properties as they are not adjacent to the site. The proposal includes re-utilizing the site as an automobile service station with a new and improved building and improved site landscaping to the maximum extent practicable. Code Enforcement Analysis: There are no active Code Compliance cases for the subject property. COMPLIANCE WITH STANDARDS AND CRITERIA: The following table depicts the consistency of the development proposal with the standards as per CDC Tables 2-701.1 and 2-704: Standard Proposed Consistent Inconsistent FAR 0.55 0.88 X Impervious Surface Ratio 0.90 0.77 X Minimum Lot Area N/A 34,155 square feet(0.78 acres) X Minimum Lot Width N/A 150 feet(Sunset Point Road) X 160 feet(N.Hercules Avenue) Minimum Setbacks Front: N/A East: 64.73 feet(to building) X 10.44 feet(to pavement) South: 25 feet(to canopy) X 15(to pavement) Side: N/A North: 11.45 feet(to building) X 10 feet(to sidewalk) West: 44.18 feet(to building) X 4.69 feet(to pavement) Maximum Height N/A 21.25 feet X Minimum N/A 12 parking spaces X Off-Street Parkin 3.9 s aces er 1,000 sf GFA Community Development Board—March 19,2013 FLD2012-11026—Page 5 _ _ Y Clearwater Level II Flexible Development Application Review PLANNING&DEVELOPMENT DEVELOPMENT REVIEW DIVISION - , s+:k,s>,nm .. COMPLIANCE WITH FLEXIBILITY CRITERIA: The following table depicts the consistency of the development proposal with the Flexibility criteria as per CDC Section 2-704.0 (Comprehensive Infill Redevelopment Project): Consistent Inconsistent 1. The development or redevelopment is otherwise impractical without deviations from X the use and/or development standards set forth in this zoning district. 2. The development or redevelopment will be consistent with the goals and policies of X the Comprehensive Plan, as well as with the general purpose, intent and basic planning objectives of this Code, and with the intent and purpose of this zoning district. 3. The development or redevelopment will not impede the normal and orderly X development and improvement of surrounding properties. 4. Adjoining properties will not suffer substantial detriment as a result of the proposed X development. 5. The proposed use shall otherwise be permitted by the underlying future land use X category, be compatible with adjacent land uses, will not substantially alter the essential use characteristics of the neighborhood; and shall demonstrate compliance with one or more of the following objectives: a. The proposed use is permitted in this zoning district as a minimum standard, flexible standard or flexible development use; b. The proposed use would be a significant economic contributor to the City's economic base by diversifying the local economy or by creating jobs; c. The development proposal accommodates the expansion or redevelopment of an existing economic contributor; d. The proposed use provides for the provision of affordable housing; e. The proposed use provides for development or redevelopment in an area that is chazacterized by other similar development and where a land use plan amendment and rezoning would result in a spot land use or zoning designation;or f. The proposed use provides for the development of a new and/or preservation of a working waterfront use. 6. Flexibility with regard to use, lot width, required setbacks, height and off-street X parking are justified based on demonstrated compliance with all of the following design objectives: a. The proposed development will not impede the normal and orderly development and improvement of the surrounding properties for uses permitted in this zoning district; b. The proposed development complies with applicable design guidelines adopted by the City; c. The design, scale and intensity of the proposed development supports the established or emerging character of an area; d. In order to form a cohesive, visually interesting and attractive appearance, the proposed development incorporates a substantial number of the following design elements: ❑ Changes in horizontal building planes; ❑ Use of architectural details such as columns, comices, stringcourses, pilasters,porticos,balconies,railings,awnings,etc.; ❑ Variety in materials,colors and textures; O Distinctive fenestration patterns; ❑ Building stepbacks;and ❑ Distinctive roofs forms. e. The proposed development provides for appropriate buffers, enhanced landsca e desi n and a ro riate distances between buildin s. Community Development Board—March 19,2013 FLD2012-11026—Page 6 � C����1'itlt��Level II Flexible Development Application Review YLANNING&DEVELOPMENT DEVELOPMENT REVIEW DIVISION . . .tx-'-�' � � � COMPLIANCE WITH GENERAL STANDARDS FOR LEVEL TWO APPROVALS: The following table depicts the consistency of the development proposal with the General Standards for Level Two Approvals as per CDC Section 3-914.A: Consistent Inconsistent 1. The proposed development of the land will be in harmony with the scale, bulk, X coverage,density and character of adjacent properties in which it is located. 2. The proposed development will not hinder or discourage development and use of X adjacent land and buildings or significantly impair the value thereof. 3. The proposed development will not adversely affect the health or safety of persons X residing or working in the neighborhood. 4. The proposed development is designed to minimize traffic congestion. X 5. The proposed development is consistent with the community character of the X immediate vicinity. 6. The design of the proposed development minimizes adverse effects, including X visual,acoustic and olfacto and hours of o eration im acts on ad'acent ro erties. COMPLIANCE WITH COMPREHENSIVE LANDSCAPE PROGRAMS: The following table depicts the consistency of the development proposal with the General Standards for Level Two Approvals as per CDC Section 3-1202.G: Consistent Inconsistent 1. Architectural theme. a) The landscaping in a comprehensive landscape program shall be designed as a X part of the architectural theme of the principal buildings proposed or developed on the parcel proposed for development;or b) The design, character, location and/or materials of the landscape treatment N/A N/A proposed in the comprehensive landscape program shall be demonstrably more attractive than landscaping otherwise permitted on the parcel proposed for development under the minimum landscape standards. 2. Lighting. Any lighting proposed as a part of a comprehensive landscape program is X automatically controlled so that the lighting is turned off when the business is closed. 3. Communiry character. The landscape treatment proposed in the comprehensive X landscape program will enhance the community character of the City of Clearwater. 4. Property values. The landscape treatment proposed in the comprehensive landscape X program will have a beneficial impact on the value of property in the immediate vicinity of the parcel proposed for development. 5. Special area or scenic corridor plan. The landscape treatment proposed in the X comprehensive landscape program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the arcel ro osed for develo ment is located. SUMMARY AND RECOMMENDATION: The Development Review Committee (DRC) reviewed the application and supporting materials at its meeting of February 7, 2013, and deemed the development proposal to be legally sufficient to move forward to the Community Development Board (CDB), based upon the following findings of fact and conclusions of law: Community Development Board—March 19,2013 FLD2012-11026—Page 7 � C�bN�r 11'�ll.l Level II Flexible Development Application Review PLANNING&DEVELOPMENT DEVELOPMENT REVIEW DMSION Findings of Fact. The Planning and Development Department, having reviewed all evidence submitted by the applicant and requirements of the Community Development Code, finds that there is substantial competent evidence to support the following findings of fact: 1. That the 0.78-acre subject property is located at the northwest corner of Sunset Point Road and N. Hercules Avenue; 2. That the subject property is located within the Commercial (C) District and the Commercial General (CG) Future Land Use Plan category; 3. That the property was recently annexed into the City in 2012; 4. That the existing improvements on the site will be demolished; 5. That the proposal includes the development of 3,010 square feet of floor area for an Automobile Service Station with twelve parking spaces; 6. That the proposal includes a building height of 21.25 feet to top of flat roof; 7. That the proposal for the automobile service station use does not include facilities for lubricating, minor repairs or vehicle service; 8. That the proposal includes a front(south) setbacks of 25 feet(to canopy) and 15 feet(to pavement), a front(southeast)setback of 14.57 feet(to pavement), front(east) setbacks of 64.73 feet(to building) and 10.44 feet(to pavement), side (west) setbacks of 44.18 feet(to building) and 4.69 (to pavement), side(north) setbacks of 11.45 feet(to building)and 18 feet(to pavement); 9. That the proposal includes front landscape buffer widths of 15 feet along Sunset Point Road and 10.44 feet along N. Hercules Avenue; 10. The proposal includes the reduction of the required ten percent (2,087 square feet) interior landscaped area as based on the vehicular use area to 3.5 percent(731 square feet); 11. That the proposal includes the elimination of the requirement to provide a five-foot wide foundation planting along south and east fa�ades of the building; 12. That the proposal includes large windows, and finish treatments such as stucco, scored stucco, cornices, stone, and a metal canopy; and 13. That there is no active Code Enforcement case for the subject property. Conclusions of Law. The Planning and Development Department, having made the above findings of fact, reaches the following conclusions of law: 1. That the development proposal is consistent with the Standards as per Tables 2-701.1 and 2- 704 of the Community Development Code; 2. That the development proposal is consistent with the Flexibility criteria as per Section 2- 704.0 of the Community Development Code; 3. That the development proposal is consistent with the General Standards for Level Two Approvals as per Section 3-914.A of the Community Development Code; and 4. That the development proposal is consistent with the Comprehensive Landscape Program standards as per Section 3-1202.G. Community Development Board—March 19,2013 FLD2012-11026—Page 8 Y ClVUl yiRl�l Level II Flexible Development Application Review PLANNING&DEVELOPIv1ENT DEVELOPMENT REVIEW DIVISION � . v's:..x;, _ . „ Based upon the above, the Planning and Development Department recommends APPROVAL of the Flexible Development approval to permit a 3,010 square foot Automobile Service Station use in the Commercial (C) District with lot area of 34,155 square feet, lot widths of 150 feet (Sunset Point Road) and 160 feet (Hercules Avenue), front(south) setbacks of 25 feet (to canopy) and 15 feet (to pavement), a front (southeast) setback of 14.57 feet (to pavement), front (east) setbacks of 64.73 feet (to building) and 10.44 feet (to pavement), side (west) setbacks of 44.18 feet (to building) and 4.69 (to pavement), side (north) setbacks of 11.45 feet (to building) and 18 feet (to pavement), a building height of 21.25 feet, and 12 off-street parking spaces as a Comprehensive Infill Redevelopment Project pursuant to Community Development Code Section 2-704.E., as well as reductions to the interior landscape island area to 731 square feet (3.5%) where 2,087 square feet (10 %) is required, and a reduction of the foundation landscaping to zero feet where five feet is required as a Comprehensive Landscape Program pursuant to Community Development Code Section 3-1202.G., subject to the following conditions: Conditions of A�proval: 1. That prior to the issuance of any building permits, the fence for the lift station be revised to be consistent with the dumpster enclosure and building fa�ade; 2. That prior to the issuance of certificate of occupancy all on-site utility facilities, whether they be existing or proposed, are to be placed underground as part of the redevelopment of the site; 3. That any/all future signage must meet the requirements of Code and be architecturally integrated with the design of the building with regard to proportion, color, material and finish as part of a final sign package submitted to and approved by Staff prior to the issuance of any permits which includes: (a) All signs fully dimensioned and coordinated in terms of including the same color and font style and size; and (b) All signs be constructed of the highest quality materials which are coordinated with the colors, materials and architectural style of the building; and 4. That the fit, finish and materials of proposed improvements to the site and/or building be consistent with those approved by Community Development Board; 5. That prior to the issuance of a Certificate of Occupancy, all proposed site improvements including but not limited to installation of landscaping and fencing be installed to the satisfaction of City Staff; and 6. That prior to the issuance of any building permits, the Fire Department may require the provision of a Water Study performed by a Fire Protection Engineer in order to ensure that an adequate water supply is available and to determine if any upgrades are required by the developer due to the impact of the project. The water supply must be able to support the needs of any required fire sprinkler, standpipe and/or fire pump. If a fire pump is required, then the water supply must be able to supply 150 percent of its rated capacity. v Prepared by Planning and Development Department Staff: Ellen Crandall,Land Resource Specialist ATTACHMENTS:Photographs Community Development Board—March 19,2013 FLD2012-11026—Page 9 � : .�.. ._ �_.. . ,.. \ ,3 -- , .;� '; ��..�"'�° i � �', _ - - �- - - �•_ "'�. � _ .-- ., . A ��. � � �, � �4 ��;':y G. �; <Lr,,... N��^I�a*a� �r y �'�' ' h ... ��' ;.� v t,."n .rte� ���7�-�w ,�,;w.Sa,�.� a,L.�� �� .:?..� ., M ' ! i u} .-�+....�''",.^: � �` �,,,.e d°'S� � �.,''lbr3 � � �,r 1 ,�•"+`��* a+•�'�.�-r � �,-.�+��h"`�•. . � y,,.. �y'y:� . +". �4.,k wf ���� T' �. a "�+^i�!,+"' �.�,,,!3« ,J�.^ r-: � ,A.`�.d .ws b. Vicw f�rom the nurthexst corner lool<ing southwest View from the east property line looking west ,.. - • ��, r ,' F'J J � . ��l� '1'�.`� � / ) j�` .l •�':L:•• _.1��., . __ "� "''• . y���- i ��Y 4� . �� ,�. R�~'-, . n jVti�� � ..._. ... ,�1PivMY�._ � , .. I � r.. I'Y # � � ♦ i i". . _._ . � ' •'�� �` �� �i ._ _. _" "etm"T�L� .� ��Iy �� �.R' 1 � ! � �'+ H�.:.�a A..A'M'J'..s ' <.-,w. ^L, {, I � �'�� ( r�i�i/{3 '.. .. s§i *��,''.�..9w " # ' ,w .',x"tra ,'&�r wa-u.. h�^ .. �e �,+ �,� ix r' b..�x� ,` � '� a ''* L�;� :�J� �.,� a..�sr `"�� .� _ `'�';. , ..,�;. �4�-��(;.+�*,�d(�:Ft�., :Y � �.� r+.:.' ' -.. .. .. .' .. ue.'�". ..ro�• _ .. r .. .� '� '�� � ��.. �� � �" . -s. ,'.!•�.._. . , � t'�...�A"i �� ete. 4s� -��,. . . ' . -� ... . � .� . View from the south property line looking northeast View from the west property line looking nurth � �� ______ .... � :. �„ �. - �' _ — � 8 E . '�4 L.� ! 1 � - a _� � _�: ;:. . �, . . ; ,-- :_.- . . _ . � - ,, �� ;�f ��., .�,. r ' . � 5'• j _ � J t i J .�'j�q N: � ' . q � If�� '�..�� � ,-s�M .fi 4 . .Y"w�44• _"_ '.-��tb#!'.,�n/M`G.t.� . , � View from the northwest corner looking southeast. View from the south property line looking east down - Sunset Point Road. 1990 Sunset Point Road FLD2012-11026 � .. , . �� � �� ___ + � '� � , � - , _;,�_-. � ��Irtifll`/�Y� ► Ji� ` ' � �` _ v � , � _ 0 NEIC�: . ��, $'.� �� ,. � ?° I� 'N + ... . �iyy.• .. p� ��. 1 � ' Y f�, I .,.... �. . , . '.:, .�. ++III��.: . .� ...,�.., ..: r,� @ + '��� � 1�` •� V ! . .� K :ia i � .. r„� . mr-..' . _ � ".�� � �?�F ' ��,.p + \ r, . � ` ; R ;� A ;, . , t�' lt� �.� , m � + Ll �� .+ .• , F.� .� � � t � , , lll ` * t'�►�y� �' � �` � + . , 4�x,1 ..M, A�-f, �� �.� _ �� � y .. , , ` .,� t�� I' �,; . �i �� � . � �r 9 �-.__ t { .. - �� . . . �1r� �¢� ; ';.. ' � � ,' . . =t ; , � � - �.�.� y . . � � •:5..� a1, i �� � r ♦ '.g. • ` � 'IA ' . . . F . ' � " w -� ;�;:;,� �-� � ���v�-r r����i r�;�� �,;��,;�,, h ~ � '� _. . ,� ��.�� �' � �� � b� � �� � � . 1 iT�.y,�,t'� .,, ' ' - '1 1` . ' �{ � � �, ' � �. ���- ` �. .t '1 � � �� , ��, '�� � ' ' . .� ' ' � � � � ' '�Jl�l�T�'F!J%�Ll�! ' r � t , , , a '� �� � •� Y ��, -�,_, �� � ��. ��► �" � ;� � � � � d `"tij 'i - r • s .. ,�` ., - , �J��r , � �� . - M «. : . j' tt� _ ,t. � ��� � .o��. �, ��' ��► ..w. �� �I: {.". ' ��jR ���• �� 'I �yfa��J � ��'+ '�. �. .y � '�` 1 �, 't: �, Aerial Map Owner: S 8� I Ventures LLC Case: FLD201 2-1 1 026 ' Site: 1990 Sunset Point Property Size: 0.78 acres PIN: 01-29-15-00000-240-0200 Atlas Page: 253A �_ _ 95 96 100 ^ 74 73 I ==' so sa 1982 � GTO 1987 � � � � Detached dwellings $ ,3,0, ; " � � � a "^ ^ � � � ? ? .- �. .. 16.86 A c �- .. .°= .. .°= <°= .°: 110 109 �08 107 106 105 104 103 102 101 I � 1965 ���� 19481948 W Park a 1944 1950 � � r_ _ � ', Q � N u rsin 1942 � 38236 � �I W g 1940 I J Home Office v ,sa, 1938 Q Ol 24I01 O> .— .Z r 118 4.4 A C �— � I �8046 �1934 �5 � RestauYantQ � � 1 1909 Automobile Retail 2 Sa6�s � Ser�a�e � � and y � 12� ; Statiorb ,� „ I� o p � � " e�- / 9713VICe `r N N . . . . ., ...� � � � � + „ SUNSET POINT RD � � � „ � � � � - - - - — - � I � 120 F O O O eN- � e�- N N N N N �'�'! M h M ��oy O ` I O N N N N N N N t�y �� O O O O O O O `a Retail Sa�es and Automobile N 61 2 4 5 66 67 �p �� N N 7N 7N 6 N B 9 80 � d ��I 5 Service Service Station "° ' " I � 6� 9 � 55 5E 2 51 50 47 46 3 2 41 � M �l1 I� Of t� I� � IS M 1 1 M t� Of �- tti h t� p� e� �y � � � O O O O O O � O O O O O p � O p � M M " N N N N N N N N N N N N N N N N N N N i Vehic�l Sales ��° � and D�s'play �aso ,� � 8 � � 0 „a i a - z °• ioo II'/ 188168 (V I 0 : T— - -� 1888 � 1881 BB p�p I 70164 � 188�B9 ,� � � Existing Surrounding Uses Map Owner: S 8� I Ventures LLC Case: FLD201 2-1 1 026 Site: 1990 Sunset Point Property Size: 0.78 acres PIN: O1-29-15-00000-240-0200 Atlas Page: 253A I � � Q o z � cn °z Z ¢ a BUFORD � a � � O � � cp �= Y o o . � J ¢ � m Q � 0 Q z Z Z ' � ° � � O � Z `n � p m � � GAYLE w � i uto'pi 0 MONTCLAIR RD "Z RADCLIFFE DR N � � > Z gE �� � o � � � Sun Tree Z � 0 c ` m m U H �? � � w � � c � � J �ak v v pR = "' SUN TREE p Bark � C���N PROJECT i= � SITE `� � � = Q Hali {a _ m �� � � �� a Ct HASTINGS LN a SUNSET POINT RD Sunset Grove Ln � - � rSU(��11�Q�4L�,�, BLVD Location Map Owner: S 8� I Ventures LLC Case: FLD201 2-1 1 026 Site: 1990 Sunset Point Property Size: 0.78 acres PIN: 01-29-15-00000-240-0200 Atlas Page: 253A 1962 BARRI 1967 y ; y h Y� � b n � n � � T ? Z � af � Of T �l W O� � q 1965 1946 1948 O`�/K a 1944 1950 '�•� l` rn � 1942 O � Q 1940 `� LMD W 1941 1938 = rn P T � W I 1934 = o z � � —���H���H tso9 ■ � � � � i ■ * � * � � w � i � � 3 o � ■ � � � � � — O1 --� °' 1903 — c°.i c°� SUNSET POINT RD „ - � � � ~ O O O O � � ap- ^ � c�V N Q�O (O O N V �D � O e I O O O O O O O � O O O � O O O � O O O O O 6 a � N N N N N N N IN N tV N N N N N �`1 N cV N <V o U E R L � • � O O O � a� � fti N N of � �y h t� o� N N N N � � O O O O O O O O O � O N N (V �Y N N N tV N N N N N � O O N N N 1890 WEST CT �, I - , — , I 1881 88 o I • 1886 d' • 1881 B6 m 1881 B9 � � Zoning Map Owner: S 8� I Ventures LLC Case: FLD201 2-1 1 026 Site: 1990 Sunset Point Property Size: 0.78 acres PIN: 01-29-15-00000-240-0200 Atlas Page: 253A Ellen Crandall 100 South Myrtle Avenue Clearwater,FL 33756 727-562-4836 ellen.crandall(a�mvclearwater.com PROFESSIONAL EXPERIENCE ■ Land Resource Specialist City of Clearwater, Clearwater, Florida February 2013 to Present Duties include site plan review of commercial and residential site plans for compliance with the Tree Preservation and Erosion Control sections of the Land Development Code; Participate in weekly BPRC and monthly DRC meetings to communicate technical tree preservation details to staff, contractors, engineers, architects and the general public. Inspect sites prior to plan review. Inspect construction sites for erosion control and tree protection. Investigate and process citizen complaints and provide conflict resolution. ■ Planner II City of Clearrvater, Clearwater, Florida May 2010 to February 2013 Duties include performing the technical review and preparation of staff reports for various land development applications, the organization of data and its display in order to track information and provide status reports. ■ Planner I City of Clearwater, Clearwater, Florida December 2009 to May 2010 Assist public customers at the Zoning Counter. Review Building Permits, Sign Permits, Business Tax Receipts, and Landscape Plans as well as Comprehensive Sign Program Applications, and Flexible Standard Developments. Regulate growth and development of the City in accordance with land resource ordinances and regulations related to community development. Respond as a City representative to citizens, City officials, and businesses concerning ordinances and regulations. Make recommendations and presentations at staff level at various review committees,boards,and meetings. ■ Community Planner Bradford County, Towanda, Pennsylvania January 2008 to May 2009 Coordinates with the 51 municipalities in Bradford County and assisted them in writing Comprehensive Plans, developing ordinances, and general public and municipal education on zoning, land use, and ordinances. I developed a comprehensive Zoning Lexicon that included zoning maps, districts and definitions for all municipalities with zoning ordinances. Assisted in the County Parks Plan and in developing a comprehensive Park's book listing all the parks in Bradford County. I assisted mapping the natural gas wells as well as printing maps and parcel data for the gas companies. ■ Intern Pennsylvania Geologic Survey, Middletown, Pennsylvania May 2006 to September 2006 Scanned geologic maps, updated documents and assisted in general office tasks. EDUCATION Bachelor of Science, -Major: Geography, -Minor: Art, -Certificate: Geo�raphic Information S sy tem SHIPPENSBURG UNIVERSl7'Y, Shippensburg, Pennsylvania ISA, International Society of Arboriculture, Certified Arborist LEED Green Associate � 1990 �unset Point RD FLD2012-11026 fld 7 Eleven � Zoning: Commercial Atlas#:253A � C ear�ater F�eX�b�eLC����Y.._____ . _ u Attached Dwellings, Mixed-Uses or Non-Residential Uses IT IS INCUMBENT UPON THE APPLICANT TO SUBMIT COMPLETE AND CORRECT INFORMATION. ANY MISLEADING, DECEPTIVE, INCOMPLETE OR INCORRECT INFORMATION MAY INVALIDATE YOUR APPLICATION. ALL APPLICATIONS ARE TO BE FILLED OUT COMPLETELY AND CORRECTLY,AND SUBMITTED IN PERSON(NO FAX OR DELIVERIES) TO THE PLANNING&DEVELOPMENT DEPARTMENT BY NOON ON THE SCHEDULED DEADLINE DATE. A TOTAL OF 11 COMPLETE SETS OF PLANS AND APPLICATION MATERIALS(1 ORIGINAL AND 10 COPIES)AS REQUIRED WITHIN ARE TO BE SUBMITTED FOR REVIEW BY THE DEVELOPMENT REVIEW COMMITTEE. SUBSEQUENT SUBMITTAL FOR THE COMMUNITY DEVELOPMENT BOARD WILL REQUIRE 15 COMPLETE SETS OF PLANS AND APPLICATION MATERIALS(1 ORIGINAL AND 14 COPIES). PLANS AND APPLICATIONS ARE REQUIRED TO BE COLLATED,STAPLED AND FOLDED INTO SETS. THE APPLICANT, BY FILING THIS APPLICATION, AGREES TO COMPLY WITH ALL APPLICABLE REQUIREMENTS OF THE COMMUNITY DEVELOPMENT CODE. FIRE DEPT PRELIMARY SITE PLAN REVIEW FEE: $200 APPLICATION FEE: $1,205 PROPERTY OWNER(PER DEED): S & I Ventures LLC MAIIINGADDRESS: P.O. Box 8589 Clearwater FL 33758 PHONE NUMBER: 727-797-0888 EMAIL: ccurry@harrisandcompany.net fl �---' 1 ~ AGENTORREPRESENTATIVE: C`µnton r'nngi„l+`�nn n/n F'li �whci,Jh phArriAthv a 0 MAILINGADDRESS: 2205 N. 20th Street Tam a FL 3360 5 z� PHONENUMBER: Office 813-223-9500 Mobile 813-449-2898 N �Q a a3 EMAIL: Liz .Abernethy@Stantec.com � O rn u! �L-.� ev w U � ADDRESS OF SUBJECT PROPERTY: 1990 Sunset Point Road Clearwater FL 33765 �' °a PARCELNUMBER(5): 01-29-00000-240-0200 � Z z 2 LEGAL DESCRIPTION: See Attached � a PROPOSED USE(S): Convenience store with gas DESCRIPTION OF REQUEST: reduction of 25 ' setback for vehicular use area; Specificolly ;dentify rhe request reduction to 15 ' landscape buffers (include oll requested code flexibility; reduce required parkinq from 15 to 12 e.g., reduction in required number of parking spaces, height setbacks, lot size,lot width,specific use,etc.J: Planning&Development Department,100 S.Myrtle Avenue,Clearwater,FL 33756,Tei:727-562-4567; Fax:727-562-4865 Page 1 of 8 Revised 01/12 ' Vlearwater Planning&Development Department Flexible Development Application " Data Sheet PLEASE ENSURE THAT THE FOLLOWING INFORMATION IS FILLED OUT, IN ITS ENTIRETY. FAILURE TO COMPLETE THIS FORM WILL RESULT IN YOUR APPLICATION BEING FOUND INCOMPLETE AND POSSIBLY DEFERRED UNTIL THE FOLLOWING APPLICATION CYCLE. ZONING DISTRIC7: _ Current C-2 (County) FUTURE LAND USE PLAN DESIGNATION: Current CG (County) EXISTING USE(currently existing on site): convenience store w/ qas (closed) PROPOSED USE(new use,if any;plus existing,if to remain): convenience StOY'e with gas SITE AREA: 3 4, 15 5 sq.ft. 0 . 7 8 4 acres GROSS FLOOR AREA(total square footage of all buildings): ►- a Existing: 1, 4 6 7 sq.ft. c—� o Proposed: 3 , Ol 0 sq.ft. •� W� MaximumAllowable: 18, 785 sq.ft. �� � a3 c°� o �=-� � w GROSS FLOOR AREA(total square footage devoted to each use,if there will be multiple uses): r�� �-.,a oU First use: 3 , O10 sq.ft. � � �� Second use: sq.ft. � Z� Z Third use: sq.ft. �� g G, o. FLOOR AREA RATIO(total square footage of all buildings divided by the total square footage of entire site): Existing: 0 . 043 Proposed: 0 . 0 8 6 Maximum Allowable: . 55 BUILDING COVERAGE/FOOTPRINT(15L floor square footage of all buildings): Existing: 3 , 2 7 9 sq.ft. ( 9 .6 %of site) Proposed: 6 , 3 52 sq.ft. ( 18 . 6 %of site)(Canopy 3 , 3 42 plus Bui lding 3 , O 10) MaximumPermitted: 18, 791 sq.ft. ( 55 %ofsite) GREEN SPACE WITHIN VEHICULAR USE AREA(green space within the parking lot and interior of site;not perimeter buffer): Existing: 0 sq.ft. ( 0 %of site) Proposed: 4 54 sq.ft. ( 1 . 3 %of site) VEHICULAR USE AREA(parking spaces,drive aisles, loading area): Existing: 14, 9 7 3 sq.ft. ( 4 4 %of site) Proposed: 21, 0 7 2 sq.ft. ( 61 , � %of site) Planning 8 Development Department,100 S.Myrtle Avenue,Clearwater,FL 33756,Tel: 727-562-4567; Fax:727-562-4865 Page 2 of 8 Revised 01N2 IMPERVIOUS SURFACE RATIO(total square footage of impervious areas divided by the total square footage of entire site): Existing: . 5 3 Proposed: • 77 Maximum Permitted: , $5 DENSITY(units,rooms or beds per acre): BUILDING HEIGHT: Existing: Existing: 19 ' +/- Proposed: Proposed: 21 ' 3" Bldg; 18 ' 9" Canopy Maximum Permitted: Maximum Permitted: 25 ' OFF-STREET PARKING: Existing: 3 Proposed: 12 � a Minimum Required: 15 � �n� Z� WHAT IS THE ESTIMATED TOTAL VALUE OF THE PROJECT UPON COMPLETION? $1 .8 mi 11 ion � W~ �� � a3 o � �Q 20NING DISTRICTS FOR All ADJACENT PROPERTY: ��r � W North: C �� �• � 00 South: C � � � z z East: C Z West: C 0 a � JIHI t Vh tLVIt1UH�lVl.11V 1 T Uf Y1YftttPfT ��C.-(r `��'JG' I'�Y�.�"r7 I, the undersigned, acknowledge that all Sworn to and subscribed before me this f '�''1 day of representations made in this application are true and ���'y�`� ,�/aZ .to me and/or by accurate to the best of my knowledge and authorize n / City representatives to visit and photograph the -�I Z�.��`{� l`�h-�'-�'YlZ.�7� ,who is personally known has property described in this application. produced /v�� as identification. �� f�L ��Vp�-- GBl.L ignature of proper y owner or repre ntative Notary p ic, '�U *" MY CdMMISSION#D 922086 My commission expires: ���-��f� EXPIRE�Sep?ember 1,2013 i?OT 398-C753 FioridahotarySer'rce. em Planning�Development Department,100 S.Myrtie Avenue,Clearwater,FL 33756,Tel:727-562-4567; Fax:727-562-4865 Page 3 of S Revised 01/12 ° learwater Planning&Development Department � � Flexible Develo ment A lication P pp � General Applicability Criteria PROVIDE COMPLETE RESPONSES TO EACH OF THE SIX(6) GENERAL APPLICABILITY CRITERIA EXPLAINING HOW, IN DETAIL,THE CRITERION IS BEING COMPLIED WITH PER THIS DEVELOPMENT PROPOSAL. 1. The proposed development of the land will be in harmony with the scale, bulk, coverage, density and character of adjacent properties in which it is located. See attached 2. The proposed development will not hinder or discourage the appropriate development and use of adjacent land and buildings or significantly impair the value thereof. See attached 3. The proposed development will not adversely affect the health or safety or persons residing or working in the neighborhood of the proposed use. See attached .----� � a 4. The proposed development is designed to minimize traffic congestion. � � zw See attached �! �� �°�+ o� J Q �L'�J �v �� � p� �� � 5. The proposed development is consistent with the community character of the immediate vicinity of the parc r ose7�for Z development. Z see attached a g 6. The design of the proposed development minimizes adverse effects, including visual, acoustic and olfactory and hours of operation impacts,on adjacent properties. See attached Planning&Development Department,100 S.Myrtle Avenue,Clearwater,FL 33756,Tel:727-562-4567; Fax:727-562-4865 Page 6 of 8 Revised 01112 Flexible Development Appiication General Applicability Criteria 1990 Sunset Point Road 1.The proposed development of the land will be in harmony with the scale, bulk,coverage,density and character of adjacent properties in which it is located. The site is currently improved with a 1,575 s.f. convenience store and 1,920 s.f.gas canopy, constructed in 1973 per the Pinellas County property appraiser. The store is currently vacant.All adjacent lands and buildings are commercial,one-story buildings of more recent construction. The south side of Sunset Point Road is occupied by a similar commercial use, a Rally gas station and convenience store. Across Hercules is a retail center. To the north is a McDonald's restaurant,with an access drive to the west of the subject property,which is screened by a row of live oak trees along its eastern property line. These surrounding commercial structures are all one story,with FAR's ranging from .07 to .36. Redevelopment of the subject property for a similar use, a one story commercial building with site improvements such as landscaping at a .086 FAR is therefore of similar scale, bulk and character to these surrounding commercial uses. 2.The proposed development will not hinder or discourage the appropriate development and use of adjacent land and buildings or significantly impair the value thereof. All adjacent lands are developed and of significantly higher improvement value. Based on property appraiser data,the McDonald's site improvements are valued at$478,155,the Rally at$395,165 and the retail center$383,510,as compared to the current value of$118,785 for improvements on the subject site. Redevelopment of the site will significantly increase the value of the property, so that it is consistent with the value of the improvements on these surrounding properties. The total estimated total value of the project upon completion is$1.8 million. 3.The proposed development will not adversely affect the health or safety or persons residing or working in the neighborhood of the proposed use. � a � [iJU E-� Redevelopment will improve health and safety by connecting the future building to the City sanitary � w� sewer system and by redesigning the access drives. The site currently has a septic tank which will be � o� removed and the future building will be served by City sanitary sewer, decreasing the possibility of ° �, w a environmental issues associated with use of septic tank system. The driveway access to the site will � � w also be brought into compliance with current standards, increasing safety and functionality of the ,� �� intersection. � � z� z z 4.The proposed development is designed to minimize traffic congestion. � a The existing access drives to Sunset Point and Hercules do not meet current standards for distance separation from the intersection. The proposed redevelopment plan will bring these drives into compliance with current standards, thereby decreasing traffic congestion at the intersection and improving overall safety and functionality. 5.The proposed development is consistent with the community character of the immediate vicinity of the parcel proposed for development. The existing building and canopy are antiquated and not in character with the surrounding commercial businesses. The McDonald's restaurant was recently remodeled (2010)with architectural enhancements and the site is well landscaped. The retail center and the Rally station also have site buffers and landscaping.The proposed redevelopment will bring the site and buildings into character of the area through upgrades to the site and construction of a new building and canopy. Site upgrades include installation of perimeter buffers with landscaping, stormwater retention facilities, replacement of deteriorated paving, and connection to City sewer. The proposed building will be architecturally finished on all sides and include color and elevation variation, lighting fixtures and architectural banding to provide visual interest to the facades. The roof includes a parapet cap,which will match the fueling canopy. The canopy columns will be architecturally finished to match the convenience store building, with similar color scheme and banding. The improvements which bring the redevelopment into character of the area are reflected in the attached building elevations and site and landscape plans. 6.The design of the proposed development minimizes adverse effects,including visual,acoustic and olfactory and hours of operation impacts,on adjacent properties. The existing, outdated structures will be demolished and replaced with a new convenience store building that will incorporate architectural design features.The site will be upgraded by removing the septic tank and installation of buffers, interior and perimeter landscaping.The landscape plan has been enhanced with shade trees that are larger than those required by Code (4" cal).The shade and understory trees are layered to create an attractive design.The entire site is planted with shrubs and ground covers which allows low volume irrigation. � �--� a� -�'1`�r z N w � o a � O � rn � c.i w�V �� � � � � ZV Z Z � a o Planning& Development Department � C earwater Flexible Development Application �� Flexibility Criteria PROVIDE COMPLETE RESPONSES TO THE APPLICABLE FLEXIBILITY CRITERIA FOR THE SPECIFIC USE(S)BEING REQUESTED AS SET FORTH IN THE ZONING DISTRICT(S)IN WHICH THE SUBJECT PROPERTY IS LOCATED. EXPLAIN HOW,IN DETAIL, EACH CRITERION IS BEIN6 COMPLIED WITH PER THIS DEVELOPMENT PROPOSAL(USE SEPARATE SHEETS AS NECESSARY). i. See attached z. 3. 4. 5. -- � � � w � Z� F- 6. � �� � W �-� C�i W U � p � � �—� Z 7. Z o a 8. Planning 8 Development Department,100 S.Myrtle Avenue,Clearwater,FL 33756,Tel:727-562-4567; Fax:727-562-4865 Page 7 of 8 Revised 01112 Flexibility Criteria C.Comprehensive in�ll redevelopment projects. 1.The development or redevelopment is otherwise impractical without deviations from the use and/or development standards set forth in this zoning district; The existing convenience store and fueling canopy were constructed in 1973 are functionally obsolete and cannot be feasibly refurbished to meet today's code requirements due to structural deficiencies and the age of structures. In addition,the site does not currently comply with current land development code standards such as parking,solid waste, stormwater, and landscaping. The proposed redevelopment will replace these antiquated facilities with a new convenience store and fueling canopy, and improve the site to the maximum extent feasible given the dimensional restrictions of the parcel. 2.The development or redevelopment will be consistent with the goals and policies of the Comprehensive Plan,as well as with the general purpose, intent and basic planning objectives of this Code,and with the intent and purpose of this zoning district; The C-2 zoning classification and Commercial General future land use allow the convenience store and gas station use. This use serves the surrounding residential community, providing everyday convenience items and gasoline. There are no waivers to the use criteria. With the exception of the parking requirement,the site meets the minimum standards with respect to lot size and setbacks for automobile service stations. The proposed FAR of.09 is well below the .55 allowable, and the proposed ISR of.77 is below the .85%allowed in this district. 3.The development or redevelopment will not impede the normal and orderly development and imnrovement of surroundine aroperties: All adjacent lands are developed. To the north is a McDonald's restaurant, which was recently redeveloped. Immediately to the west is the access road for the McDonald's. Across Sunset Point Road is a Rally gas station and convenience store, and across Hercules Avenue is a commercial multi-tenant building. 4. �_�_" i.i.f � 4.Adjoining properties will not suffer substantial detriment as a result of the proposed developm � � � �-�,� Z L: All adjacent lands are developed and of significantly higher improvement value. Based on � `�-:� a �, :�> property appraiser data,the McDonald's site improvements are valued at$478,155,the Rally o �'� o� at$395,165 and the retail center$383,510, as compared to the current value of$118,785 for °' �"� � r.� iu c.) improvements on the subject site. Redevelopment of the site will significantly increase the � �?�� value of the property, so that it is consistent with the value of the improvements on these � � �� surrounding properties. The total estimated total value of the project upon completion is � Z $1.8 million. Z � a 5.The proposed use shall otherwise be permitted by the underlying future land use category, be compatible with adjacent land uses,will not substantially alter the essential use characteristics of the neighborhood;and shall demonstrate compliance with one or more of the following objectives: a.The proposed use is permitted in this zoning district as a minimum standard,flexible standard or flexible development use; A convenience store with gas is a permitted use. b.The proposed use would be a significant economic contributor to the city's economic base by diversifying the local economy or by creating jobs; The building is currently vacant, and redevelopment will bring jobs back to the property. c.The development proposal accommodates the expansion or redevelopment of an existing economic contributor; The proposed improvements are a redevelopment of the existing use. d.The proposed use provides for the provision of affordable housing; This is a non-residential project, and therefore this does not apply. e.The proposed use provides for development or redevelopment in an area that is characterized by other similar development and where a land use plan amendment and rezoning would result in a spot land use or zoning designation;or The surrounding uses are retail/restaurant of similar character. No plan amendment or rezoning is required for the proposed redevelopment. f.The proposed use provides for the development of a new and/or preservation of a working waterfront use. This site is not located on the waterfront and therefore this does not apply 6. Flexibility with regard to use, lot width, required setbacks, height and off-street parking are justified based on demonstrated compliance with all of the following design objectives: ��________` � a.The proposed development will not impede the normal and orderly development and �� W improvement of the surrounding properties for uses permitted in this zoning district; °� As previously noted,the surrounding properties are all developed with commercial uses. � �,, w a � ca a3 � o0 b.The proposed development complies with applicable design guidelines adopted by the ci , Q., w u There are no specific design guidelines for this area of the City. "� N o� � o °°c c.The design,scale and intensity of the proposed development supports the established or � � ?� z emerging character of an area; g � a The site is currently improved with a 1,575 s.f. convenience store and 1,920 s.f.gas canopy, constructe in 1973 per the Pinellas County property appraiser. The store is currently vacant.All adjacent lands and buildings are commercial, one-story buildings of more recent construction. The south side of Sunset Point Road is occupied by a similar commercial use, a Rally gas station and convenience store. Across Hercules is a retail center. To the north is a McDonald's restaurant, with an access drive to the west of the subject property, which is screened by a row of live oak trees along its eastern property line. These surrounding commercial structures are all one story,with FAR's ranging from .07 to .36. Redevelopment of the subject property for a similar use, a one story commercial building with site improvements such as landscaping at a .086 FAR is therefore of similar scale, bulk and character to these surrounding commercial uses. d. in order to form a cohesive,visually interesting and attractive appearance,the proposed development incorporates a substantial number of the following design elements: • Changes in horizontal building planes; • Use of architectural details such as columns,cornices, stringcourses, pilasters, porticos, balconies, railings,awnings,etc.; •Variety in materials,colors and textures; • Distinctive fenestration patterns; • Building stepbacks; and • Distinctive roofs forms. As depicted in the attached building elevations, all of these design elements have been included.The proposed building will be architecturally finished on all sides and include color and elevation variation, lighting fixtures and architectural banding to provide visual interest to the facades. The fenestration along the front of the building includes panes to break-up the large expanse of window.The roof includes a parapet cap,which will match the fueling canopy. The canopy columns will be architecturally finished to match the convenience store building, with similar color scheme and banding. e.The proposed development provides for appropriate buffers, enhanced landscape design and appropriate distances between buildings. As shown on the site and landscape plan, existing pavement along Sunset Point and Hercules will be removed, access drives reduced and defined and landscape buffers installed. The landscape buffer width along Sunset Point is 10-feet and the buffer along Hercules ranges from 10-12'. The width of the buffers is constrained primarily due to the site dimensions, and the design requirements for fueling truck movement.The landscape plan has been enhanced with shade trees that are larger than those required by Code (4" cal).The shade and understory trees are layered to create an attractive design.The entire site is planted with shrubs and ground covers which allows low volume irrigation. �� a w 0 �`� z� � �� � o� �� J Q) �Ll �-� r+ w U > �� �25, � �O � � Z� Z 2 � a o (`� ������ Planning&Development Department � l� e Flexible Develo ment A lication p pP � Affidavit to Authorize Agent/Representative 1. Provide names of all property owners on deed-PRINT full names: S & I Ventures LLC 2. That(I am/we are)the owner(s)and record title holder(s)of the following described property: 1990 Sunset Point Road, Clearwater FL 33765 Parcel ID#01-29-15-00000-240-0200 3. That this property constitutes the property for which a request for(describe request): 4. That the undersigned(has/have)appointed and (does/do)appoint: Elizabeth Abernethy Stantec Consultinq;Charlev Carpenter,HFA;and/or Peter Zent as(his/their)agent(s)to execute any petitions or other documents necessary to affect such petition; 5. That this affidavit has been executed to induce the City of Clearwater, Florida to consider and act on the above described property; 6. That site visits to the property are necessary by City representatives in order to process this application and t authorizes City representatives to visit and photograph the property described in this application; � W �f"""___'i c� 7. Tha_t!I/y�l tha i�n�iarcianari aiithnritv,harehy rartify that tha fnravninp i�triia anri rnrrart: !—�' - - is�., �— � � C�o.�--- N o a Property Owner Property Owner r� � W S&I Ventures �� `� o� Property Owner Property Owner p `� �� � z z STATE OF FLORIDA,COUNTY OF PINELLAS � � BEFORE ME THE UNDERSIGNED,AN OFFICER DULY COMMISSIONED BY THE LAWS OF THE STATE OF FLORID , THIS b a h DAY OF (� G?%<�'.�'����l�-' , �L'�:� , PERSONALLY APPEARED `��'�L''///P,5�� Gf � ��-�l/� r(_,I -`-� WHO HAVING BEEN FIRST DULY SWORN DEPOSED AND SAYS THAT HE/SHE FULLY UNDERSTANDS THE CONTENTS OF THE AFFIDAVIT THAT HE/SHE SIGNED. �'�'ti/�r'"".+`ti,r�'4^��t"i.r"'. �� / � , �_ �, 2o�`Y°�e�n Notary Public State oi Florida �L,�. Cheryl Curry ��� a My Commission DD84690o Notary Public Signat e '�of f�oo- Expires 12/18/2012 Notary Sea tamp � ` My Commission Expires: Planning&Development Department,100 S.Myrtie Avenue,Clearwater,FL 33756,Tel:727-562-4567;Fax:727-562-4865 Page 8 of 8 Revised 01/12 ° learwat�r Planning&Development Department � v Flexible Develo ment A p pplication � Site Plan Submittal Package Check list IN ADDITION TO THE COMPLETED FLEXIBLE DEVELOPMENT(FLD)APPLICATION,ALL FLD APPLICATIONS SHALL INCLUDE A SITE PLAN SUBMITTAL PACKAGE THAT INCLUDES THE FOLLOWING INFORMATION AND/OR PLANS: �Responses to the flexibility criteria for the specific use(s) being requested as set forth in the Zoning District(s) in which the subject property is located. The attached Flexible Development Application Flexibility Criteria sheet shall be used to provide these responses. [�Responses to the General Applicability criteria set forth in Section 3-914.A. The attached Flexible Development Application neral Applicability Criteria sheet shall be used to provide these responses. �CJ A signed and sealed survey of the property prepared by a registered land surveyor including the location of the property, dimensions, acreage, location of all current structures/improvements, location of all public and private easements including official records book and page numbers and street right(s)-of-way within and adjacent to the site. rll� Ja If the application would result in the removal or relocation of mobile home owners residing in a mobile home park as �� provided in F.S.§723.083,the application must provide that information required by Section 4-202.A.5. IA If this application is being submitted for the purpose of a boatlift, catwalk, davit, dock, marina, pier, seawall or other si milar P marine structure, then the application must provide detailed plans and specifications prepared by a Florida professional engineer, bearing the seal and signature of the engineer, except signed and sealed plans shall not be required for the repair or replacement of decking, stringers, railing, lower landings, tie piles, or the patching or reinforcing of existing piling on r"ivate and commercial docks. �Jd A site plan prepared by a professional architect,engineer or landscape architect drawn to a minimum scale of one inch equals 50 feet on a sheet size not to exceed 24 inches by 36 inches that includes the following information: ❑ Index sheet of the same size shall be included with individual sheet numbers referenced thereon. fl �In.th�rrn�u c��lo In��tj�n m�n�n�l r,latc nronarorl > > �r �r.�r�. . ❑ Identification of the boundaries of phases,if development is proposed to be constructed in phases. �� �— �-�._. 2 ❑ Location of the Coastal Construction Control Line (CCCL), whether the property is located within a Special Flood o Area,and the Base Flood Elevation (BFE)of the property,as applicable. �r'''� z u � u�H Sa ❑ Location,footprint and size of all existing and proposed buildings and structures on the site. � � �� ❑ Location and dimensions of vehicular and pedestrian circulation systems, both on-site and off-site, with proposed p� � w u of access. "—' c.i w� ❑ Location of all existing and proposed sidewalks, curbs, water lines, sanitary sewer lines, storm drains, fire hydra � °°� seawails and any proposed utility easements. �•� � z� z ❑ Location of onsite and offsite stormwater management facilities as well as a narrative describing the pro e g stormwater control plan including calculations. Additional data necessary to demonstrate compliance with the t� d Clearwater Storm Drainage Design Criteria manual may be required at time of buiiding construction permit. ❑ Location of solid waste collection facilities, required screening and provisions for accessibility for collection. ❑ Location of off-street loading area, if required by Section 3-1406. ❑ All adjacent right(s)-of-way, with indication of centerline and width, paved width, existing median cuts and intersections and bus shelters. ❑ Dimensions of existing and proposed lot lines, streets, drives, building lines, setbacks, structural overhangs and building separations. ❑ Building or structure elevation drawings that depict the proposed building height and building materials. Planning 8 Development Department,100 S.Myrtle Avenue,Clearwater,FL 33756,Tel: 727-562-4567; Fax:727-562-4865 Page 4 of 8 Revised 01/12 _ _ ❑ Typical floor plans,including floor plans for each floor of any parking garage. ❑ Demolition plan. ❑ Identification and description of watercourses, wetlands, tree masses, specimen trees, and other environmentally sensitive areas. ❑ If a deviation from the parking standards is requested that is greater than 50% (excluding those standards where the � � di erence between the top and bottom of the range is one parking space), then a parking demand study will need to be rovided. The findings of the study will be used in determining whether or not deviations to the parking standards are approved. Please see the adopted Parking Demand Study Guidelines for further information. A tree survey showing the location, DBH and species of all existing trees with a DBH of four inches or more, and identifying those trees proposed to be removed,if any. A tree inventory, prepared by a certified arborist, of all trees four inches DBH or more that reflects the size, canopy, and /condition of such trees may be required if deemed applicable by staff.Check with staff. � A Traffic Impact Study shall be required for all proposed developments if the total generated net new trips meet one or more of the following conditions: ■ Proposal is expected to generate 100 or more new trips in any given hour(directional trips,inbound or outbound on the abutting streets)and/or 1,000 or more new trips per day;or ■ Anticipated new trip generation degrades the level of service as adopted in the City's Comprehensive Plan to unacceptable levels;or ■ The study area contains a segment of roadway and/or intersection with five reportable accidents within a prior tweive month period, or the segment and/or intersection exists on the City's annual list of most hazardous locations, provided by the City of Clearwater Police Department;or ■ The Traffic Operations Manager or their designee deems it necessary to require such assessment in the plan review process. Examples include developments that are expected to negatively impact a constrained roadway or developments with unknown trip generation and/or other unknown factors. A landscape plan shail be provided for any project where there is a new use or a change of use;or an existing use is improved or remodeled in a value of 25% or more of the valuation of the principal structure as reflected on the property appraiser's current records, or if an amendment is required to an existing approved site plan; or a parking lot requires additional lanrlcranina ni�rciiant tn tha nrnyicinnc nf Artirla 3 fliuicinn 1d_ Tha lanrlcra�a �I?n chall inrl�irla tha fnllrnniina infnrmatinn if .........,....�.....p�.._...__.... ._ _.._ � �•-•- not otherwise required in conjunction with the application for development approval: ❑ Location, size, description, specifications and quantities of all existing and proposed landscape materials, including botanical and common names. ❑ Existing trees on-site and immediately adjacent to the site, by species,size and location,including drip line. ❑ Interior landscape areas hatched and/or shaded and labeled and interior landscape coverage, expressed both in square feet, exclusive of perimeter landscaped strips, and as a percentage of the paved area coverage of the parking lot and vehicular use areas. ❑ Location of existing and proposed structures and improvements, including but not limited to sidewalks, walls, fences, pools, patios, dumpster pads, pad mounted transformers, fire hydrants, overhead obstructions, curbs, water lines, sanitary sewer lines, storm drains, seawalls, utility easements, treatment of all ground surfaces, and any other features that may influence the proposed landscape. ❑ Location of parking areas and other vehicular use areas, including parking spaces, circulation aisles, interior landscape islands and curbing. ❑ Drainage and retention areas, including swales,side slopes and bottom elevations. ❑ Delineation and dimensions of all required perimeter landscaped buffers including sight triangles,if any. D � ' ���; � NOV 2 9 20i2 .' �' Planning 8�Development Department,100 S. Myrtle Avenue,Clearwater,FL 33756,Tel: 7 7�- 62 �J, �t.�NNIN��, Page 5 of 8 ,� CITY OF C�1 Eq������G�=T f Wilso�Miller � Stantec . 6900 Professional Parkway East Sarasota,FL 34240 (941)907-G900 August 27, 2012 Himanshu Patni, P.E. Traffic Operations City of Clearwater P.O. Box 4748 Clearwater, Florida 33758 Reference: 7-Eleven Store Sunset Point Road/Hercules Avenue Intersection Traffic Impact Statement Dear Mr. Patni: This letter serves to summarize the traffic impacts for the subject project for your review and comment. The proposed development is located at the northwest corner of the Sunset Point Road/Hercules Avenue intersection. The property currently has an abandoned gas station with supporting infrastructure. 7- tieven proposes io consiruci a 3,u�u square rooi convenience store wiin i� iueiiing posiiions. ihe existing on-site structures will be demolished and removed. The build out year for the 7-Eleven is 2013. The project location is shown in Figure 1. The City of Ciearwater's Traffic Impact Study Procedures document was reviewed to identify what level of analysis is required as part of the 7-Eleven project. The subsequent sections of this letter summarize the 7-Eleven trip generation, preliminary distribution and existing roadway conditions. ��'".�1 � � ��, ���� � � � >> . o ��:; �; ��A �� ��� i `� ���;° _.._` � ��� �,�,�., NN�NG&,�E�1E�O1��TFc� , : P� C,� F C`F�"�-�°�� . WilsonMiller � Stantec August 27,2012 Himanshu Patni City of Clearwater Traffic Operations Page 2 of 5 Reference: 7-Eleven Store Sunset Point Road/Hercules Avenue Intersection Traffic Impact Statement , — � Y��� :,; x. ��t ��,�,�.� � �� E�� �� ������ _ � �_,k's . r+►� ,��'- p �i � � - �� , ��.' � ��"�� � ,�• �P f. K t �y, �� � � I'�' �� ,� �., ��i . :��}, `,_ � �, ; xx� 4 � - .. - �'` �' i '�. . � i �'"�%'*''�°� � ' �,.�. � ; 5 + � � ��� �'�� � �'�a � #�'"" �-,, ' h, f W '��.,�=t� � �� � t:�, � �4. ,� " ... :'_ .._ ' . _ .. . � -� . -rs _ .„, _ _ . 4�... ;� .�w. :��r : , ; , E, ,. .� : �,^'r�?"�,�y .:"^y� _ .�.�r .-�3. N l� � t # ♦k'"%� _ <^"'f� � °�°. x� w � 'rr.< � .*,� €a �., �� A�- �w a:.' � �. . � � ..,!� «.. ���e� �', �•�_ . � ���� 'i'• � { �."!� , �i ` . � � t';– �, x� .. � �� `�� � � r ~ _._ : _ � � .f�'* � ^s�. ,s.� r�-, �, .�. ...:tZ €»�� F N-«»::.�«;..�.;... '�:;:.4�w.. J�:.... � _ ,�., ., ra�n+¢:�vc..b.wa.:ri. ..: . �6r.c .�. ��'� �,IL�" �.� _.��, � ,.��„� � ��' , ' Sunset Pomt Road „r�� �� � .�-:� ,� ,� .., ��� �. } ��„� `:�...y� _����..:� " c:�.,.���,.�''$.r1..._ r � ;;.:.�� --.�► � � - � � : - - , 4-___ � _.� �t. � - � , r�� "s! �:��� �' � � �, f.��" __ r � :r �; �, .� , a� ,i:=s �� ....s � — ` t °i 4 �jQ� .. � �, ` � � � , ;�� ,' y• j � ,,.,��, � �" � � � �- - _ _ � �� ,�O . Ny..a � ��4 .:`.�r�, � * � f 1� R� �., rW w � .,, .,.�,;. �''��,wY : .�_ �.. � . � '`�'}tsr-r.. ' y ,.�;' . ���r ,� �p,�'�- 4=� �'¢'*�� �++w� Source:Goog/e,20?2 � � ���;�+ i�� y� � � Figure 1: Project Location Trip Generation Traffic volumes generated by the proposed development were estimated using the Institute of Transportation Engineers (ITE) Rates, Trip Generation — the 8th Edition (2008). Land Use Code 853 (Convenience Market with Gasoline Pumps) was used to estimate the trip generation potential based on square footage of the convenience store. No Internal Capture trips were used in the analysis; however, Pass-by Capture trips were based on the ITE Trip Generation Handbook, 2"d Edition Table 5.13. Table 1 illustrates the daily trip generation and Table 2 illustrates the PM peak-hour trip generation from the proposed development. ....-<;., r 's a ?� � \.�--�� t' `': � L�� ' � � � �� �� 0 2� ��t'� �-�'�. t�►4� �„�--��F�� ��. � �--° - o;-i!���'r, 1..-. . ;'�r1;L �� p�•'t_. ' 1 .,�.. ..� �`�'��..�G[���._+,��',.���''' . WilsonMiller 1 Stantec August 27,2012 Himanshu Patni City of Clearwater Traffic Operations Page 3 of 5 Reference: 7-Eleven Store Sunset Point Road/Hercules Avenue Intersection Traffic Impact Statement Table 1: Daily Trip Generation Daily Daily Daily Total Trips Passby Capture Trips New Extemal Trips ITE Land Use Category Units �Ve�°Pment Daily Trip Rate/ �ter E�cit Pa�y Size Equation S lit S lit Total Enter Exit % Total Enter Exit Total Enter Exit Comenience Market with per 1,000 SF 3,010 T=845.60(x) 50% 50% 2,545 1,273 1,272 66% 1,680 840 840 865 433 432 Gasoline Pumps-853 Table 2: PM Peak-Hour Trip Generation PM PM PM Peak Total Trips Pass-by Capture Trips New Extemal Trips Development PM Peak Trip Rate/ pa�y ITE Land Use Category Units Size Equation Enter Exit Total Enter Exit % Total Enter Exit Total Enter Exit S lit S lit Cornenience Market with Per 1,000 SF 3,010 T=62.57(x) 50% 50% 188 94 94 66% 124 62 62 64 32 32 Gasoline Pumps-853 Based on the estimated trip generation from the 7-Eleven, the site will not generate 100 or more new trips in any given hour' or 1,000 or more new trips per day. This trip generation assumes that there are no trip credits from the previous use on the property. Trip Distribution A preliminary distribution of project traffic was conducted using existing peak-hour traffic volumes obtained from the Pinellas County MPO 2011 Level-of-Service Report. The preliminary distribution is shown in Table 3 and indicates that no roadway segments meet the threshold of 5% of the daily or peak-hour traffic. Table 3: Project Traffic Distribution Existing Traffic percent New ProjectTraffic Significant Road Name and Se ment LOS Number peak Pro'ect 9 Standard of Lanes Daily � Daily % Peak % Impact? Hour Tra�c Impact Hour Impact (>5°�� HerculesAvenue Drew St to Sunset Point Rd D 4 14,079 736 18% 156 1.1°/a 12 1.6% No Sunset Point Rd to Site D 2 12,832 670 42% 363 2.8% 27 4.0% No Site to Virginia A� D 2 12,832 670 16% 141 1.1% 10 1.5% No Sunset Point Road Belcher Rd to Hercules A�,ee D 4 25,736 1,345 33°/a 284 1.1% 21 1.6% No Hercules Ave to Site D 4 25,726 1,345 61% 528 2.1% 39 2.9% No Site to Keene Rd D 4 25,736 1,345 33% 284 1.1% 21 1.6% No ,;�":.�1;. � � U � 1, �� , p � , ! , The PM peak-hour of generator was used,which produces the highest hourly trip generation. �(��'� �i; ��j�'� �� EP.� ��, E�JE���M�FR�.__. :�'� r';�•� .C,RaD`,,r•: _. , ,. .- . , - 5 . ... � Wils�nMiller � Stantec August 27,2012 Himanshu Patni City of Clearwater Traffic Operations Page 4 of 5 Reference: 7-Eleven Store Sunset Point RoadlHercules Avenue Intersection Traffic Impact Statement Existinq and Future Traffic Existing traffic volumes were obtained from the Pinellas County MPO 2011 Level-of-Service Report and indicate that both adjacent roadway segments are operating at acceptable level-of-service standards. The existing conditions are shown in Table 4. Table 4: Existing Traffic Conditions Adopted LOS Existing Road Name and�Segment . LOS Number Service Peak-Hour v/c Standard of Lanes Volume , Volume Ratio Hercules Avenue Drew St to Sunset Point Rd D 4 1,764 736 0.42 Sunset Point Rd to Site D 2 832 670 0.81 Site to Virginia A�e D 2 832 670 0.81 Sunset Point Road Belcher Rd to Hercules A�e D 4 1,764 1,345 0.76 Hercules A�e to Site D 4 1,764 1,345 0.76 ISite to Keene Rd D 4 1,764 1,345 0.76 I The 7-Eleven project is anticipated to be completed in 2013. The future traffic conditions were estimated using a conservative 2% annual background traffic growth rate. Two years of background growth were used since the volumes from the Pinellas County MPO 2011 Level-of-Service Report were collected in 2011. As Table 5 indicates, sufficient capacity exists with the inclusion of the background traffic and project traffic. Table 4: Future Traffic Conditions Adopted LOS : ExisUng Road Name and Segment ` LOS.' Number Service Peak-Hour �ckground Project Total y/c - Standard of Lanes Volume Volume Traffic Traific Trafflc Ratio Hercules Avenue Drew St to Sunset Point Rd D 4 1,764 736 30 12 778 0.44 Sunset Point Rd to Site D 2 832 670 27 27 724 0.87 Site to Virginia A�e D 2 832 670 27 10 707 0.85 Sunset Point Road Belcher Rd to Hercules Aee D 4 1,764 1,345 54 21 1,420 0.80 Hercules A�e to Site D 4 1,764 1,345 54 39 1,438 0.82 Site to Keene Rd D 4 1,764 1,345 54 21 1,420 0.80 rY , _ `,. . � : �; � �� U �, II, � ',� o �-----���,,'J���� �. r �' . , � a , _.� WilsgnMiller � Stantec August 27,2012 Himanshu Patni City of Clearwater Traffic Operations Page 5 of 5 Reference: 7-Eleven Store Sunset Point Road/Hercules Avenue Intersection Traffic Impact Statement Given the documentation provided in this Traffic Impact Statement, it does not appear that the 7-Eleven project meets the City of Clearwater's requirements to conduct a Traffic Impact Study. Another factor that would require a traffic study would be if there is a safety issue at the Sunset Point Road/Hercules Avenue intersection or the adjacent roadway segments. The last 12 months of crash data was not available to be reviewed as part of this submittal; however, based on the Pinellas County MPO 2009 Crash Facts Report, the Sunset Point Road/Hercules Avenue intersection was not one of the top 100 crash intersections in 2009 or one of the top 50 crash intersections from 2006 through 2009. Please let me know if any further analysis will be required as part of the 7-Eleven project. Should you have any questions, please feel free to contact me. Sincerely, WilsonMiller Stantec � �� � �. ,,�- , �_ Matthew Crim, P.E., PTOE Transportation Engineer Ph: 832-523-9111 Fax: 941-907-6910 matt.crim an.stantec.com cc: Liz Abernathy, AICP, WilsonMiller Stantec Frank Domingo, P.E., WilsonMiller Stantec D �o� �� �oe� � T���� ; P��N1NG &DEVE�OPMEN , ° Clearwater Planning&Development Department � Comprehensive Landscaping Application IT IS INCUMBENT UPON THE APPLICANT TO SUBMIT COMPLETE AND CORRECT INfORMATION. ANY MISLEADING, DECE E INCOMPLETE OR INCORRECT INFORMATION MAY INVALIDATE YOUR APPLICATION. � a � ALL APPLICATIONS ARE TO BE FILLED OUT COMPLETELY AND CORRECTLY,AND SUBMITTED IN PERSON(NO FAX OR DELI Z W TO THE PLANNING&DEVELOPMENT DEPARTMENT BY NOON ON THE SCHEDULED DEADLINE DATE. � � �Q 0 0, A TOTAL OF 11 COMPLETE SETS OF PLANS AND APPLICATION MATERIALS(1 ORIGINAL AND 10 COPIES)AS REQUIRED N O ARE TO BE SUBMITTED FOR REVIEW BY THE DEVELOPMENT REVIEW COMMITTEE. SUBSEQUENT SUBMITTAL F �T °'� N 0 U COMMUNITY DEVELOPMENT BOARD, IF NECESSARY, WILL REQUIRE 15 COMPLETE SETS OF PLANS AND APPLI TI• � MATERIALS(1 ORIGINAL AND 14 COPIES). PLANS AND APPLICATIONS ARE REQUIRED TO BE COLLATED,STAPLED AND p "� INTO SETS. [� Z Z_ Z THE APPLICANT, BY FILING THIS APPLICATION, AGREES TO COMPLY WITH ALL APPLICABLE REQUIREMENTS I� a COMMUNITY DEVELOPMENT CODE. PROPERTY OWNER(PER DEED): S & I, LLC MAILINGADDRESS: P.O. Box 8589 Clearwater FL 33758 PHONE NUMBER: 727-797-0888 EMAIL: ccurry@ harrisandcompany.net AGENTORREPRESENTATIVE: Elizabeth Abernethy, Stantec and Charley Carpenter, HFA MAILINGADDRESS: 2205 N 20th Street, Tampa FL 33605 PHONENUMBER: Office 813-223-9500; Mobile 813-449-2898 EMAIL: Liz AtJernetlly@stantec .com ADDRESS OF SUBJECT PROPERTY: 1990 Sunset Point Road, Clearwater DESCRIPTION OF REQUEST: Reduce required landscape buffers from 15 ' to 10-12 ' Specifically identify the request Reduce re�uired setback to paving from 25 ' to 10-12 ' (include all requested code ffexibility; Reduce required parkinq from 15 to 12 spaces e.g., reduction in required number of parking spaces, height, setbacks, lot size,lot width,specific use,etc.): STATE OF fLORIDA,COUNTY OF PINELLlkS �� I��Or�;.t��- I, the undersigned, acknowledge that all Sworn to and subscribed before me this_ day of representations made in this application are true and y/��`Ut�-�� , �D/.� .to me and/or by accurate to the best of my knowledge and authorize City representatives to visit and photograph the ��f� �--f�1 �b�'YlP�lu�' ,who is personally known has property described in this application. produced /V�l� as identification. � U/�v�cti t,.� Signature of property owner or representative Notary public, � sy��JQ� /► ! �S�rP��� 17l��I �IG i f1 1�'J�V��` My commission expires: :ra.• ".�� ;a, :t, E���,� EXPIRF_S Sep?em er Planning 8�Development Department,100 S.Myrtle Avenue,Clearwater,FL 33756,Tel 7,���=��67; Fa*��;2�KSfa�8S�e.com Page 1 of 2 �� e�v�se3 �Z _ ° Clearw r Planning&Development Department _ a�� Com rehensive Landsca in A licatio p P g pP n � Flexibility Criteria PROVIDE COMPLETE RESPONSES TO EACH OF THE FIVE(5) FLEXIBILITY CRITERIA EXPLAINING HOW, IN DETAIL,THE CRITERION IS BEING COMPLIED WITH PER THIS COMPREHENSIVE LANDSCAPING PROPOSAL. �� � w 0 1. Architectural Theme: �., Z� a. The landscaping in a Comprehensive Landscaping program shall be designed as a part of the architectural th th o a 3 principal buildings proposed or developed on the parcel proposed for the development. c� p� ° wa rn W U � �� Z Z►}- OR Z b. The design,character, location and/or materials of the landscape treatment proposed in the Comprehensive La ds�a i a program shall be demonstrably more attractive than landscaping otherwise permitted on the parcel pro e or development under the minimum landscape standards. The landscape plan has been enhanced with shade trees that are larger than code (4") . The dhade and understory trees are lavered to create an attractive design. The entire site is �lanted allowina use of low volume irricration 2. Lighting. Any lighting proposed as a part of a Comprehensive Landscaping program is automatically controlled so that the lighting is turned off when the business is closed. The business will be operated 24-hours/day, and therefore this is not applicable. 3. Community Choracter. The landscape treatment proposed in the Comprehensive Landscape Program will enhance the community character of the City of Clearwater. The existing site has no landscaping adjacent to the roadways . The �ro�osed redevelo�ment will remov �avement and r a 10 12 ' land ca�g buffer, significantly enhancing the aesthetics of the site 4. Property Volues.The landscape treatment proposed in the Comprehensive Landscaping program will have a beneficial impact on the value of the property in the immediate vicinity of the parcel proposed for development. The current value of the subject parcel is significantly lower than the value of the surroundinq commercial sites . The surrounding sites have landscape buffers and interior landscapin . 5. Specioi Area or Scenic Corridor Plan. The landscape treatment proposed in the Comprehensive Landscape Program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the parcel proposed for development is located. A variety of shade and understory trees are proposed, includinq live oaks, youpon hollys, ligustrum, fan and cabbage palms, bald cypress and elms . Hedges include cleyera, yew podocarpus, indian hawthorn, and viburnum Planning&Development Department,100 S.Myrtle Avenue,Clearwater,FL 33756,Tel:727-562-4567; Fax:727-562-4865 Page 2 of 2 Revised 01/12 November 2, 2012 E � EVEn � � o � z - N �~ � OQ rn � DRAINAGE STATEMENT � > � o � FOR � �y �- z Z p ng. Store No. 36452 NW Corner of Sunset Point Road & Hercules Avenue Clearwater, FL .,�,,;���i;��;,� .,���'`,'� -, _ ��'�; ;��'�\ � �r� ' ' ':\ � /%, �� r`� !;:, i. Prepared by: ; Y��f __ . �-�� 1 w �'�S''. � ` , �� i y _. ,, _ Andrew Siyter, P.E. �; ,- _ � FL Lic. 66157 = = 1 ; �::<� �' ��`•'� `" .. _ e'�, ,t_, :,� ; � � �rf�fz , ; ; : �L c�R ���4a r 809 Southwest A Street, Suite ZO1 Phone: 479.273.7780 Bentonville. AR 72712 Fax: �179.273.9436 �v�vw.hfa-ae.com DRAINAGE STATEMENT The existing property is located at the northwest corner of Sunset Point Road and Hercules Avenue in Clearwater, FL. The site is previously developed land consisting of an existing commercial building, existing pavement, and remaining open area. The existing site appears to drain via sheet flow uncontrolled into the adjacent right of ways adjacent to the property. The site is located in flood zone X according to flood map panel 1203C01037H. There is no base flood elevation for properties with this designation. The Floor elevation will be set based upon design storm flood routings for the 100 year storm event. The anticipated Floor elevation is approximately 62.50 NAVD. The proposed drainage system consists of a combination of exfiltration trench and dry detention that will provide storm water quality and quantity attenuation prior to discharge to an existing storm drain in the Hercules Avenue right of way. The 300 LF of 3'x6' exfiltration trench provides approximately 1,240 cu-ft of attenuation of volume while the dry detention area of 1,434 sf provides approximately 1,924 cuf-ft of attenuation (see attached calculations). The total attenuation is 3,240 cu-ft. The volume of attenuation provided within the combination of exfiltration and dry detention area will exceeds the City and SWFWMD criteria for retention/detention volume by exceeding one inch of volume over the site equal to 2,831 cu-ft. The proposed design has been prepared with the intent of ineeting all requirements of the Florida Department of Transportation, the City of Clearwater, and the South West Florida i/Vater Management uistrici. � .` ��i -�' � rl � �l l--�J �'�f N UJ h � S�, � i.:.. � �<; cs�s �tt.� � c.� t�u C; ' � 0� � �s O Z � � z z z � a 11/1/2012 4:52 PM Drainage Statement 36452 7-Eleven Volume Calculations Volume Calculations to Provide Retainment One inc;h of Attenuation Across the site Site Area= 33,978 sf One inch Volume=(Site Area s�x(inches of rainfall)x(1 ft/12 inches�=(33,978sf)x(1)x(1/12)= 2831.00 cuft p � � � i��lV 2 9 2012 PLANNI�G&DEVELOPMENT DEPT C 36452 Volume Calculations Rev 0 11/1/2012 5:08 PM Drainage Statement :36452 7-Eleven Exfiltration Trench Calculations Afull=area of pipe see caic Vtr= 907.00 cu-ft Du=storage height in unsaturated trench see calc Tel=elevation of top of trench 59.00 ft Storage�within pipe SHWT=Sean high water table elevation 56.00 ft Atrench=storage area in trench see calc Apipe=((3.14)xD"2)/4=((3.14)x(1.5'^2))/4= 1J66 sqft f=fillable porosity of rock 0.40 Wtr=trench bottom width 6.00 ft Storage:Height in Trench(unsaturated depth) H=height of trench= 3.00 ft Du=Tel-Bottom E1= 3.00 ft Vtr=Volume of trench water quality required see calc Trench Pipe Size(DIA.) 1.50 ft Storage�Area in Trench Lreq=required trench length see calc Bottem E1=Bottom of Trench elevation= 56.00 ft Atrencti=f(Wtr x Du-Apipe)=.4(6ftx3ft-1.77sf)= 6.49 sf 2xVtr=t_x(((3.14xD"2)/4)(1-f)+WtrxHxf) 1814.00 cuft Lrequired= 219.62 ft Trench Length Provided= 300.00 ft Note: See mass balance report for recovery time calculation � d � � � �g �.012 ��V PMENRDEPT PLPNNI T����VEi.RW T 36452 Exfiltraton Calculation