Loading...
02/03/199802/03/1998 3166 MCMULLEN BOOTH RD BETHEL LUTHERAN CHURCH To: Art Kader, Interim Director, Parks & Recreation; Mike Gust, Traffic Operations Engineer, Bob Perkins, Engineer II; Mike Quillen, Environm~ytal Engineer; James Goodloe, Fire Marshall; Don McCarty, Sensor Design Planner; Steve Doherty, Central _. Permitting Supervisor. From: Don McCarty, Central Permitting, Senior Design Planner Subject: BETHEL LUTHERAN CHURCH -. Date: February 3,1998' Please find attached the revised site plan for BETHEL LUTHERAN CHURCH which has been submitted by the applicant for certification. Refer to the Summary Notes for the DRC meeting of October 23, 1997 for assurance in assuring that all DRC directed changes have been made to the plan. If you find the site plan acceptable ,please initial and date. If you do have an objection and/or recommendation, please comment below or attach your comments in a memo. PLEASE DO NOT MARK PLAN AS IT HAS BEEN SUBMITTED FOR CERTIFICATION. .~/.~'7/~G C /1 ~/LE /yvD/LA~~ l9'Stfr~,~~,. /t9 T.t~ /!/cit?~ ENS"-4.~.cc T -T.µE lfirmlfia ~it.on. ~ C'. D . ,! C/ DRCFINALBETHELLUTHERAN b AI~n1N~~ENT~ [_M ~• Z q 9~ ~ ! October 23, 1997DevelopmentReuiew Committee Meeting ITEMZBethelLutheran Church James Maglio, Solid Waste Superintendent: 1. Show location and screening of dumpster on the plan. Note visual screening and a minimum 12 ft. front access to dumpster is required. Mike Quillen, Environmental Engineer: 1. All new parking lot areas shall meet City landscaping requirements adjacent to the North, South and East property lines, 2. Provide a copy of the SWFVUMD permit to Engineering Services prior to issuance of the requisite building permit, and 3. Acquire clearing and grubbing and tree removal permits (or no tree verification form) from Engineering Services prior to issuance of the requisite building permit. Bob Perkins, Engineer II: 1. Show dumpster location as approved by the Solid Waste Division. Steve Doherty, Central Permitting Supervisor: 1. Delete all grass parking spaces which may have been included as open space in the front yard open space calculations. Mike Gust, Traffic Operations Engineer: 1. Show lane configuration of adjacent roadways, 2. Show adjoining property driveway access and affected site areas, 3. show location and dimensions of driveways, aisles, parking stalls and all internal design features, 4. Show all pavement markings, signage and traffic control devices. Compliance with Manual on Uniform Traffic Control Devices is required, 5. Provide handicap parking and access compliant with City, State, and Federal ADA standards, 6. Obtain a Pinellas County permit for driveway access or other work within the Pinellas County Road right-of--way, 7. Provide a minimum of 24 ft. aisle width behind all parking spaces, and 8. Pay the applicable Pinellas County Transportation Impact fee in accordance with the applicable Pinellas County ordinance. Dcc-05~-97 09:39A Lloveras Baur & Stevens 8137848153 f'-~1 Lloveras, Baur & Stevens Engineers -Surveyors -Planners 29228 U.S. Highway 19 North Clearwater, Florida 33761 Phone: (813)784-3965 • Fax: (813)784-8153 To: Don McCarty Company: City of Clearwater _ From: Mike Lloveras Fax: 562-4576 Date: December 5, 1997 Time: Subject: Bethel Lutheran Church -Driveway, Parking 8~ Building Renovations Number of pages including cover sheet: 1 LBBeS J.N. Hard copy to follow: Yes ! No IF THIS TRANSMISSION IS [NTERRIfPTED, PLEASE CALL 813-784-3965 Message: Don, We last requested a status report on October 29t", but we still have had no action. What is the status of the City's review of this project? When is the DRC meeting? Please call Tom Radcliffe at our firm to give us an update. Thanks, ~, -...~ .. .~; ~~ ~ ~ ~`~~`~ ~~ 1 Mike ~ DEC 0 5 1997 CENTRRL PERMITTING CITY OF CLEARWATER To: Don McCarty Fax: 562-4576 FAX MESSAGE OFFICE CITY OF CLEARWATER DEPARTMENT OF CENTRAL PERMITTING MUNICIPAL SERVICES BUILDING 100 SOUTH MYRTLE AVENUE P.O. BOX 4748 CLEARWATER, FL 34618-4748 FAX PHONE - (813) 562-4576 PHONE - (813) 562-4567 December 8, 1997 TO: ATTN: Tom Radcliffe Lloveras, Baur and Stevens, Engineers, Surveyors and Planners FROM: Don McCarty, Central Permitting Coordinator REGARDING (Project Name): Bethel Lutheran Church 3166 McMullen Booth Rd. FAX PHONE: (813)784-8153 The City of Clearwater Development Review Committee Summary Notes of October 23, 1997 are attached for you information and use. Please call Steve Doherty, (Ph. 562-4585) if you have any questions. CC: Steve Doherty TOTAL PAGES (INCLUDING THIS PAGE): 2 DRCAMTOOLFAX ~~ DEVELOPME~T'I' REVIEW COMMITTEE Central Permitting Department October 23T, 1997 at 9:30 a.m. Conference Room 216 Standard review comments fot 3 (Cc (v M c.l~vtrLEn1- P>oca COURTESY REVIEW ~v. Reviewed by: (f' Department name: Tra '~`~ G ~ i v)~ Please return comments to Steve Doherty CITY OF CLEARWATER TRAFFIC ENGINEERING SITE PLAN REVIEW CHECKLIST The following checklist has been provided to assist in the efficient review of site plans submitted to the City of Clearwater for Traffic Engineering approval. While care has been taken to include the most common items required for successful site plan review, this list should not be considered as all inclusive and all items may not be applicable to every site plan submitted. Show geometrics and lane configuration of all abutting roadways. Show adjoining property driveway accesses and affected site areas. Show location and dimensions of driveways, aisles, parking stalls and all internal design features (including but not limited to; landscape islands, medians, lighting standards, cart corrals, bike racks, bollards, gates, dumpster enclosures, etc.). Show all pavement markings, signage and traffic control devices. Use must comply with standazds set forth by the Manual on Uniform Traffic Control Devices (MLTTCD). (~ Indicate the location of lighting fixtures and show with 90 degree cutoffs directed away from abutting streets and residential properties. Show required parking calculation and the number of spaces provided. Provide handicap parking and access compliant with City, State & Federal Americans with Disabilities Act (ADA) standards. ^ Provide loading zone(s) per City Code. ^ Provide vehicle stacking area(s) per City Code. ^ Provide new, upgraded or repaired sidewalks compliant with City Code and ADA standards. ^ Determine site impact and subsequent roadway design changes needed. ^ Obtain a Significant Change of Use determination from Florida Department of Transportation (FOOT) per Florida Statute 335. ^ Obtain FOOT permit for driveway access or other work within the State Road right-of--way. Obtain Pinellas County permit for driveway access or other work within Pinellas County Road right-of--way. . ^ Execute a cross parkingroint access agreement between sites after review and approval by City Staff. Transportation Impact Fee (TIF) to be assessed per Pinellas County TIF ordinance. DEVELOPMENT REVIEW COMMITTEE Central Permitting Department October 23T, 1997 at 9:30 a.m. Conference Room 216 Standard review comments for BETHEL LUTHERAN CHURCH • COURTESY REVIEW Reviewed b Department name: ~ ~r ~ ~ c~ S~ ~ Please return comments to Steve Doherty A. Before the Site Plan can be certified, the applicant must complete the following action(s)checked below: ZONING 1.Show the following on the site plan: _a. Legal description of the property. _b. Site area (square feet and acres). _c. Number of dwelling units and hotel units proposed and the resulting net density. _d. Floor area devoted to each category of use. _e. Floor area ratio. _f. Property owner's name, address and telephone number and the designated project representative name, address and telephone number. (and Eax numbers). _~. Perimeter landscape buffer _h. Parking formula calculation Eor each use. _i. Locations of all driveways, parking areas and curb cuts. _j. Delineation in mapped form and computation of the area of the sited devoted to building coverage, open space for the lot, open space for the front yard and building coverage expressed in sq. ft. and as a percentage of the overall site. _k. Location and screening of all refuse containers/compactors. _l. North arrow. _m. Zoning assigned to the subject property and surrounding properties depicted on the plan. _n. Identify and distinguish between the new and existing buildings and driveways as well as other features on the plan. 3. Identify changes to the site data table iF this is a plan amendment. 5.Show all contiguous streets & roads. 7.Display the site address on the site plan, obtaining assistance as needed from the responsible Zoning Specialist in establishing the correct address. 8.Limit the site plan to one page. 9.Legally record a Unity of Title for the project site and furnish proof of such action. l0.Show the date(s) and condition(s) for approval of: _(a) variance(s)/conditional use approvals by the Planning & Zoning &/or the Development Code Adjustment Board(s); or, _(b) a variance Erom the Flood Board for construction within 18 Eeet of a seawall. FIRE DEPARTMENT 12.Show on the plan a fire department connection a minimum of 15 ft. from the structure, adjacent to a paved drive and within 30 ft. of a fire hydrant assembly to provide for sprinklers. 13.Locate on the plan minimum 20 Ft wide (a) FIRE LANE(S) on the N , E S . W ,side of the structure beginning not closer to the structure than 10 feet. 14.Show minimum turning radii for designated drives and fire lanes as 42 feet on the plan. 15.Locate a FIRE HYDRANT ASSEMBLY on the plan not more than 300 Feet from the structure at TRAFFIC ENGINEERING 16. Show on the site plan the installation and maintenance of uniform traffic control devices at appropriate locations in accordance with the standards set forth by the Manual on Uniform Traffic Control Devices as adopted by the Florida Department of Transportation under Rule 14-115.010, Florida Administrative Code. 19. Show applicable Florida Statute number for handicapped parking spaces. 20. Show all striping, pavement markings, signage and trafEc control devices on the site plan conforming to F.D.O.T. Standard Indices-1995 edition and F.A.C. 14- 110 (no 4" striping is to be shown). 21. Show dimensions of aisles, parking stalls, entrances and measurements for like plan features on the plan. 22. Show all pavement markings, signage and traEf c control devices on the site plan. 23. Adjust handicap spaces to meet governmental standards with the correct handicap signs. 24. Adjust parking stalls and/or driveways on the plan to the satisfaction of the Traffic Engineer. 25. Indicate the location of lighting Fixtures in the parking areas on the site plan. 26. Show all on-site lighting with 90-degree cutoffs directed away from abutting streets right-oE way and residential properties. 27. Obtain a Significant Change of Use Determination Erom the FDOT per Florida Statute 335. 28. Execute across-parking/access easement linking the site with the site and specifying the exact number and location of the spaces that are to be jointly used by and between the sites after review and approval of the easement/agreement by the appropriate City StaEE 29. Address and resolve the need for right turn/left turn auxiliary lanes and the queuing for traffic related to the project. ENVIRONMENTAL MANAGEMENT 30. Provide a copy of the SVi/FWMD permit application and calculations to Environmental Management. 31. Show all protected trees by size, species and location. 32. Show total paved vehicular use area and total interior landscape areas expressed in square feet and as a percentage of the overall site in the site plan data block. 33. Provide dimensions on the plan Eor perimeter landscape buffers. 34. Reflect the use of raised curbs or protective timbers on the site plan where interior landscaped areas abut pavement. 35. Depict all required parking lot interior areas on the plan by shading or cross-hatching. ENGINEERING PLAN REVIEW 36. Show ADA ramps for sidewalks on the site plan. 37. Complete the Dumpster Requirement Form and return it to the City Solid Waste Department. 38. Add a note to the site plan stating "It is the responsibility of the owner to roll the dumpstet to a designated location at an assigned time as approved by the Solid Waste Superintendent." 39. State on the construction plan that the detector check should be DDCVA with the by-pass meter installed by the City with fee paid by contractor. 40. State on the plan that the 6" fire line tap to the G" City water line is to state "6x6 tap" so that City Utility Accounts ~vill know what fee to bill the contractor. 41. Show backflow device(s) on plans as RPD. 42. Show all proposed utilities, storm water retention/detention systems and 50' perimeter contour elevations. 43. Have the final site plan signed and sealed by a Professional Engineer registered in the State of Florida. PARKS AND RECREATION 44. Pay the required Open Space and Recreation Assessment Fee with review by the Clearwater Parks and Recreation Department. 45. Note that the project is exempt from the City's Open Space and Recreation Assessment Fees. B . Before the City can issue building permits, the applicant must complete the following actions: ENVIRONMENTAL MANAGEMENT 1. Furnish the SWFWMD permit to Clearwater Environmental Management. 2. Acquire clearing and grubbing and tree removal permits or a no tree verification form Erom Environmental Management. 3.Provide drainage calculations ENGINEERING PLAN REVIEW 3.Obtain and furnish evidence of all applicable permits from other governmental agencies including but not limited to: _(a) FDOT permit for work within the right-oE way to Engineering Services; _(b) Pinellas County Public Health Unit Permit, Ingress/Egress and a 10 foot Utility Easement over the proposed water mains up to and including meters, backflow prevention and hydrants. 4.Pay the sewer impact assessment fee, based on the size of the water meter with assistance in determining the fee Erom Central Permitting/Licensing specialists. C. Before the City can issue a Certificate of Occupancy, the applicant must complete the following actions: ZONING 1.Add note to plan: "All site lighting will be directed away from adjoining properties and street right-of-ways.. TRAFFIC ENGINEERING 2.Pay the Transportation Impact Fee as called Eor by the Pinellas County Transportation Impact Fee Ordinance with assistance in determining the fee from the Clearwater Traffic Engineering Office. ENGINEERING PLAN REVIEW 4.Bring all substandard sidewalks and sidewalk ramps adjacent to or a part of the project up to standard, including ADA, and install sidewalk where none exists in the street right of way. 5.Have the City install backflow prevention devices with the owner/applicant paying all applicable fees. 6.Visually screen the dumpster and provide gates with a minimum 12-foot clear ~~ g opening to the front for access by Solid Waste vehicles. ~~~~~ 'had ~oc~ ~6 `' 7.Furnish as-builts and an engineer's certification to Engineering Services. D. Complete the following actions as indicated: ZONING l.Obtain the requisite building permits within one(1) year from the site plan certification date to prevent e!~piration of the site plan certification. 2.Obtain the requisite certificate(s) of occupancy within three (3) years of the site plan certification date to prevent expiration of the site plan certification. 3.Obtain review of and permits for signs and fencing/walls through separate review and permitting procedures. '~' Q .. DEVELOPMENT REVIEW COMMITTEE Central Permitting Department October 23T, 1997 at 9:30 a.m. Conference Room 216 Standard review comments for BETHEL LUTHERAN CHURCH COURTESY REVIEW Reviewed by: Department name: ~ ~~/~~"~~~~ ~~- Please return comments to Steve Doherty A. Before the Site Plan can be certified, the applicant must complete the following action(s)checked below: ZONING 1.Show the following on the site plan: _a. Legal description of the property. _b. Site area (square feet and acres). _c. Number of dwelling units and hotel units proposed and the resulting net density. _d. Floor area devoted to each category of use. _e. Floor area ratio. _E Property owner's name, address and telephone number and the designated project representative name, address and telephone number. (and fax numbers). _~. Perimeter landscape buffer _h. Parking formula calculation for each use. _i. Locations of all driveways, parking areas and curb cuts. _j. Delineation in mapped form and computation of the area of the sited devoted to building coverage, open space for the lot, open space for the front yard and building coverage expressed in sq. ft. and as a percentage of the overall site. _k. Location and screening of all refuse containers/compactors. _l. North arrow. _m. Zoning assigned to the subject property and surrounding properties depicted on the plan. _n. Identify and distinguish between the new and existing buildings and driveways as well as other features on the plan. 3. Identify changes to the site data table if this is a plan amendment. S.Show all contiguous streets & roads. 7.Display the site address on the site plan, obtaining assistance as needed from the responsible Zoning Specialist in establishing the correct address. 8.Limit the site plan to one page. 9.Legally record a Unity of Tide Eor the project site and furnish proof of such action. l0.Show the date(s) and condition(s) For approval oE: _(a) variance(s)/conditional use approvals by the Planning & Zoning &/or the Development Code Adjustment Board(s); or, _(b) a variance from the Flood Board Eor construction within. l8 feet of a seawall. FIRE DEPARTMENT 12.Show on the plan a fire department connection a minimum of 15 ft. from the structure, adjacent. to a paved drive and within 30 Et. of a fire hydrant assembly to provide for sprinklers. 13.Locate on .the plan minimum 20 Ft wide (a) FIRE LANE(S) on the N . E S . W ,side of the structure beginning not closer to the structure than 10 feet. 14.Show minimum turning radii for designated drives and fire lanes as 42 Eeet on the plan. 15.Locate a FIRE HYDRANT ASSEMBLY on the plan .not more than 300 feet from the structure at TRAFFIC ENGINEERING 16. Show on the site plan the installation and maintenance of uniform traffic control devices at appropriate locations in accordance with the standards set forth by the Manual on Uniform Traffic Control Devices as adopted by the Florida Department of Transportation under Rule 14-115.010, Florida Administrative Code. 19. Show applicable Florida Statute number Eor handicapped parking spaces. 20. Show all striping, pavement markings, signage and traEEtc control devices on the site plan conforming to F.D.O.T. Standard Indices-1995 edition and F.A.C. 14- 110 (no 4" striping is to be shown). 21. Show dimensions of aisles, parking stalls, entrances and measurements for like plan features on the plan. 22. Show all pavement markings, signage and traffic control devices on the site plan. 23. Adjust handicap spaces to meet governmental standards with the correct handicap signs. 24. Adjust parking stalls and/or driveways on the plan to the satisfaction of the Traffic Engineer. 25. Indicate the location of lighting Fixtures in the parking areas on the site plan. 26. Show all on-site lighting with 90-degree cutoffs directed away Erom abutting streets right-of--way and residential properties. 27. Obtain a Significant Change of Use Determination from the FDOT per Florida Statute 335. 28. Execute across-parking/access easement linking the site with the site and specifying the exact number and location of the spaces that are to be jointly used~by and between the sites after review and approval of the easement/agreement by the appropriate City StaFE 29. Address and resolve the need for right turn/left turn auxiliary lanes and the queuing for traEEc related to the project. ENVIRONMENTAL MANAGEMENT 30. Provide a copy of the SWFWMD permit application and calculations to Environmental Management. 31. Show all protected trees by size, species and location. 32. Show total paved vehicular use area and total interior landscape areas expressed in square feet and as a percentage of the overall site in the site plan data block. 33. Provide dimensions on the plan for perimeter landscape buffers. 34. Reflect the use of raised curbs or protective timbers on the site plan where interior landscaped areas abut pavement. 35. Depict all required parking lot interior areas on the plan by shading or cross-hatching. ENGINEERING PLAN REVIEW 36. Show ADA ramps for sidewalks on the site plan. 37. Complete the Dumpster Requirement Form and return it to the City Solid Waste Department. 38. Add a note to the site plan stating "It is the responsibility of the owner to roll the dumpstet to a designated location at an assigned time as approved by the Solid Waste Superintendent." 39. State on the construction plan that the detector check should be DDCVA with the by-pass meter installed by the City with fee paid by contractor. 40. State on the plan that the 6" Ere line tap to the 6" City water line is to state "6x6 tap" so that City Utility Accounts will know what fee to bill the contractor. 41. Show backflow device(s) on plans as RPD. 42. Show all proposed utilities, storm water retention/detention systems and 50' perimeter contour elevations. 43. Have the final site plan signed and sealed by a Professional Engineer registered in the State of Florida. PARKS AND RECREATION 44. Pay the required Open Space and Recreation Assessment Fee with review by the Clearwater Parks and Recreation Department. 45. Note that the project is exempt From the City's Open Space and Recreation Assessment Fees. B. Before the City can issue building permits, the applicant must complete the following actions: ENVIRONMENTAL MANAGEMENT 1. Furnish the SWF1VhiD permit to Clearwater Environmental Management. _~2. Acquire clearing and grubbing and tree removal permits or a no tree verification form from Environmental Management. 3.Provide drainage calculations ~,Q. „~,,~--- ~r ~~ .,`~" ~-- `E, ~o ~ hRe- ~ Q-+~ cG,~~ QQ~- C> ~y Ccx~ Q~~~ ~~`~~ 8--~@s~ ~ ~ rvr Sou ENGINEERING PLAN REVIEW ~ ~ ~ ~ ~$, 3.Obtain and furnish evidence of all applicable permits from other governmental agencies including but not limited to: _(a) FDOT permit Eor work within the right-of--way to Engineering Services; _(b) Pinellas County Public Health Unit Permit, Ingress/Egress and a 10 foot Utility Easement over the proposed water mains up to and including meters, backflow prevention and hydrants. 4.Pay the sewer impact assessment Fee, based on the size of the water meter with assistance in determining the fee from Central Permitting/Licensing specialists. C. Before the City can issue a Certificate of Occupancy, the applicant must complete the following actions: ZONING 1.Add note to plan: "All site lighting will be directed away from adjoining properties and street right-of-ways.. TRAFFIC ENGINEERING 2.Pay the Transportation Impact Fee as called for by the Pinellas County Transportation Impact Fee Ordinance with assistance in determining the fee Erom the Clearwater Traffic Engineering Office. ENGINEERING PLAN REVIEW 4.Bring all substandard sidewalks and sidewalk ramps adjacent to or a part of the project up to standard, including ADA, and install sidewalk where none exists in the street right of way. S.Have the City install backflow prevention devices with the owner/applicant paying all applicable fees. 6.Visually screen the dumpster and provide gates with a minimum 12-foot clear opening to the front for access by Solid Waste vehicles. 7.Furnish as-builts and an engineer's certification to Engineering Services. D. Complete the following actions as indicated: ZONING l.Obtain .the requisite building permits within one(1) year from the site plan certification date to prevent expiration of the site plan certification. 2.Obtain the requisite certificate(s) of occupancy within three (3) years of the site plan certification date to prevent expiration of the site plan certification. 3.Obtain review of and permits for signs and Fencing/walls through separate review and permitting procedures. Engineers -Surveyors -Planners National Society of Professional Engineers Florida Engineering Society American Society of Civil Engineers Florida Surveying and Mapping Society American Congress on Surveying and Mapping Institute of Transportation Engineers Florida Planning and Zoning Association National Association of Enviromental Professionals September 9, 1997 Mr. Don McCat-ty Development Technical Services City of Clearwater Central Permitting Department P. O. Box 4748 Clearwater, Florida 33756 Re: Bethel Lutheran Church Driveway, Parking & Building Modifications Dear Don: i~~~ 1 7 E ? ~ ~~ + v i ;.t, .. f~~ ~~ *E ~~ CI-~~° ~~ ~l_~a~n~J~1TE~ Enclosed please find the information listed below regarding the Site Plan for the captioned project. 1. Sixteen (16) blueprints (24" x 36" - 1 sheet) of the Site Plan for the proposed changes to the driveway, parking and building at the above referenced project. 2. One (1) endorsed copy of the City of Clearwater Application for Site Plan Review. Due to the fact that this is a minor revision to a previously approved site, we are requesting a waiver of the Site Plan review fee on behalf of Bethel Lutheran Church. It is our understanding that this project will be scheduled for a Development Review Committee Meeting in the near future. Prior to the DRC Meeting, you will let us know when the public hearing advertising sign, which will be prepared by the City, is ready. We will then pick up the sign, and have it posted in front of the Church. Please let us know if you have any questions, or if you need any additional information. Very truly yours, PE, PSM, AICP MSL:mc/bethel cc: Rev. Timothy Parch, Pastor w/1 print of Site Plan Landon Wetzel w/1 print of Site Plan 29228 U.S. Hwy. 19 North Pinellas: (813) 784-3965 Clearwater, Florida 33761 Pasco: (813) 842-7635 Fax: (813)784-8153 i ,~; CENTRAL PERMITTING DEPARTMENT ,,I, . 10 S. MISSOURI AVENUE =_ CLEARWATER, FL 34616 E ~~~ Telephone: 462-6567 -Fax: 462-6476 APPLICATION FOR SITE PLAN REVIEW Bethel Luthern Church Phone:1813 1 799-3010 Applicant (Owner of Record): 3166 McMullen Booth Road City: Clearwater State: FL Zip: 33761 Address: Represent Address: City: State: Zip: preparer of Plan: Lloveras, Baur & Stevens Professional Tide: 29228 U.5. Hi hwa 19 North Clty: Clearwater Address: g y State: FL Zip: 33761 Telephone: 81 13 1 784-39.65 Title of Proposed Site PlanlProject: Bethel Luthern Church -Driveway, Parking & Building Addition Parcel Number:_ 21 / 28 / 16 / 00000 / / 3166 McMullen Booth Road General Location end Addresstif known) of Property: Zoning: PSP Existing Use of Property: Church Church Proposed Use of Property:-___._ and Use Plan Classification: Institutional If variances andlor conditional uses are involved, explain (if more space required attach separate sheet); N/A YOU MAY BE SUBJECT TO A PARKS AND RECREATION FEE: City Code of Ordinances, Seca. 54.01 - 54.35 requires a parks and recreation Impact fee to he paid for all nonresidential projects over 1 acre M size and ail residential developments. Has this property complied with these ordinances) Yes If yes, explain how and when: Assessed.just value of property (attach verification: As of (date): Moat recent sales price (attach verification): Your Fee for this Slte Plan Review is i . Ptease submit that amount with this completed application. The applicant, by filing this application agrees to comply with Section 43.21 of the City's Land Development Code. THAT SECTION I:~ ATTACHED FOR YOUR INFORMATION AND COMPLIANCE. Signature': of Landon Wetzel, Chairman ~ g p lease attach a statement signed •If the application is signed by an Individual other than the prOplication.ner (e. the re resentativel, p by the property owner authorizing this individual to sign the app 11 TFIE SITE PLANS MUST BE DRAWN WITH TFIE NORTH ARR_O_W__TO THE_T_OP OF THE PAGE. 21 THE SfTE PLANS MUST BE FOr LDS TO NO LARGER THAN 9" x 12". 4) SUBMIT 16 COPIES OFT HE SITE PLAN OR REVIEW WITN THIS APPLICA TON BLE .•r.,e• N/A Telephone: ( 1 Revised 9/ Engineers -Surveyors -Planners National Society of Professional Engineers Florida Engineering Society American Society of Civil Engineers Florida Surveying and Mapping Society American Congress on Surveying and Mapping Institute of Transportation Engineers Florida Planning and Zoning Association National Association of Enviromental Professionals December 29, 1997 Mr. Don McCarty Central Permitting Coordinator City of Clearwater Central Permitting Department '~ P. O. Box 4748 Clearwater, Florida 33756 i Re: Bethel Lutheran Church Final Site Plan Certification Dear Don: ,~~~ Engineers -Surveyors -Planners Michael S. Lloveras, PE, PSM, AICP Pinellas: (813) 784-3965 Pasco: (813) 842-7635 29228 U.S. Hwy. 19 North Fax: (813) 784-8153 Clearwater, Florida 33761 Home: (813) 784-7765 Enclosed please fmd twelve (12) blueprints (24" x 36" - 1 sheet) of the Final Site Plan for the captioned project. This plan has been modified in accordance with the comments that we received from the Development Review Committee. It is our understanding that you will be utilizing these prints of the Final Site Plan for certification. Please let us know if you have any questions, or if you need any additional information. Very PE, PSM, AICP cc: Rev. Timothy Parch, Pastor w/1 print of Final Site Plan Landon Wetzel w/1 print of Final Site Plan 29228 U.S. Hwy. 19 North Pinellas: (813) 784-3965 Clearwater, Florida 33761 Pasco: (813) 842-7635 Fax: (813) 784-8153