Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FLD2005-07063
• 100 South Myrtle Avenue Clearwater, Department Clearwater, Florida 33756 Awwater Telephone: 727-562-4567 u Fax: 727-562-4865 ? SUBMIT ORIGINAL SIGNED AND NOTARIZED APPLICATION ? SUBMIT 14 COPIES OF THE ORIGINAL APPLICATION including 1) collated, 2) stapled and 3) folded sets of site plans ? SUBMIT APPLICATION FEE L1205.00 paid 0 ORIGINAL CASE #: _FLD2005-07063__ DATE RECEIVED: RECEIVED BY (staff initials): ATLAS PAGE #: _-2698 ZONING DISTRICT: _C (Commercial)_ LAND USE CLASSIFICATION: SURROUNDING USES OF ADJACENT PROPERTIES: NORTH: ___C (Commercial)----- - SOUTH: -Church (common facilities)- WEST: --Single Family Residential__ EAST: ___C (Commercial)----- * NOTE: 15 TOTAL SETS OF INFORMATION REQUIRED (APPLICATIONS PLUS SITE PLAN SETS) FLEXIBLE DEVELOPMENT. APPLICATION Comprehensive Infill Project (Revised 12/30/2004) -PLEASE TYPE OR PRINT A. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4-202.A) APPLICANT NAME: _--Homeless Emergency Project Inc.___-----____ _-_---__-_-----_-----_---_ MAILING ADDRESS: _-1120 N. Betty Lane, Clearwater, Florida 33755-- PHONE NUMBER: ----- (727) 442-9041------------ -__-___- FAX NUMBER: ----- -(727) 446-1516-------------------- -___-_ PROPERTY OWNER(S): --Homeless Emergency Project, Inc. (Must include ALL owners as listed on the deed - provide original signature(s) on page 6) AGENT NAME: __-Lafferty ARCHitecture Group LLC / Stephen B. Lafferty, MAILING ADDRESS: _-11414 Seminole Boulevard, Suite 5, Largo, FL PHONE NUMBER: CEL L NUMBER: 727-399-1 727-647-8697 FAX NUMBER: 727-399-5777 E-MAIL ADDRESS: _____steve@LaffertyARCH.com -------------- --_ B. PROPOSED DEVELOPMENT INFORMATION: (Code Section 4-202.A) STREET ADDRESS of subject site:--1200 Betty Lane, Clearwater, FL 33755 -_--____ LEGAL DESCRIPTION: --- As noted on the Site Survey---------------- --___ (if not listed here, please note the location of this document in the submittal) PARCEL NUMBER: 10 / 29 / 15 / 26550 / 003 / 0070--------- ----------- --____ PARCEL SIZE: --.43 Acres -------------------------------------1YI A611y:Wr .' L)i- (acres, square feet) CITY Cat f:: PROPOSED USE(S) AND SIZE(S): --Proposed use remains unchaged - Transient Accomodation -18 units (number of dwelling units, hotel rooms or square footage of nonresidential use) This project is to replace the existing dining hall, a Modular Building with a permanent structure _________ DESCRIPTION OF REQUEST(S): __See Attachment A for additional information.-____--___---- --------- _-__ Attach sheets and be speck when identifying the request (include all requested code deviations; e.g. reduction in required number of parking spaces, specific use, etc.) -Existing density, drainage, setback conditions to remain unchanged, Significant improvement in parking access, aesthetics and landscaping. Page 1 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater U DOES THIS APPLICATION INVOLVE THE TRANSFEI *0P DEVELOPMENT, OR A PREVIOUSLY APPROVED (CERTI documents) Sn" ^ L-1-p U U L5 j AUG 12 2005 11-/I 0 n R( R I NI A I Ki)?-..,,;,... ?,,•c,t LOPMENT:.RIGHTS'( DR)?A PREVIOUSLY APPROVED PLANNED UNIT SIfE CAN?'YES ___ NO __XX__ (if yes, attach a copy of the applicable C. PROOF OF OWNERSHIP: (Code Section 4-202.A.5) O SUBMIT A COPY OF THE TITLE INSURANCE POLICY, DEED TO THE PROPERTY OR SIGN AFFIDAVIT ATTESTING OWNERSHIP (see page 6) D. WRITTEN SUBMITTAL REQUIREMENTS: (Code Section 3-913.A) ? Provide complete responses to the six (6) GENERAL APPLICABILITY CRITERIA - Explain howeach criteria is achieved, in detail: 1. The proposed development of the land will be in harmony with the scale, bulk, coverage, density and character of adjacent properties in which it is located. __The proposed development will not change the scale, bulk, coverage or density of the site or adjacent propeerties.____ __The proposed enhancements bring significant improvement in the character and experience of the community, as it provides for a --permanent, more aesthetically appealing structure than currently exists. ------- _ 2. The proposed development will not hinder or discourage the appropriate development and use of adjacent land and buildings or significantly impair the value thereof. __The proposed development will encourage the improvement of adjacent land and buildings by adding to the appearance. _______ --Placing a permanent and more attractive structure on the site will improve the value of the adjacent properties. The facility will --replace the existing, dated modular building, not adding to the capactity of the facility, but better serve those currently being served. 3. The proposed development will not adversely affect the health or safety or persons residing or working in the neighborhood of the proposed use. ___The proposed project will signicantly improve the health and safety of persons residing or working the the neighborhood, as the facility ---will be designed to current building and life safety codes and will increase accessiblity to disabled persons.____________ 4. The proposed development is designed to minimize traffic congestion. ___The proposed development will improve traffic patterns, as existing parking which requires backing into the Right Of Way is being- ----eliminated and changed to parallel parking as recommended by Staff. The existing site is extremely constrained, and this unique ---facility does not generate significant traffic, as the previously homeless residents do not generally posess vehicles.____ 5. The proposed development is consistent with the community character of the immediate vicinity of the parcel proposed for development. ___See response to number 1 above. The new structure will be surrounded by the existing structure on 3 of 4.sides The existing structure is being re-roofed to better blend and coordinate with surrounding structures having green roofs. - 6. The design of the proposed development minimizes adverse effects, including visual, acoustic and olfactory and hours of operation impacts, on adjacent properties. ____The proposed design enhances the visual appearance considerably, and enhanced landscaping and front elevation treatment will -----improve acoustic and olfactory concerns. A below ground grease interceptor will also replace an above-ground fixture ad! it _ ----sanitary safety. Operational hours may be shortened due to the ability to feed more persons in one sifting ._____________________ O Provide complete responses to the ten (10) COMPREHENSIVE INFILL REDEVELOPMENT PROJECT CRITERIA (as applicable) - Explain how each criteria is achieved in detail: 1. The development or redevelopment of the parcel proposed for development is otherwise impractical without deviations from the use, intensity and development standards. ___The current dining & cooking facilities, a modular building which no longer complies with current codes, are ageing to the point where it is no ----longer financially viable to maintain and upgrade the structures in their current configuration. In order to properly (and better) serve those ---currently being served, a new structure must be built. The residential rooms surround the site on 3 sides and are not being modified. Page 2 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater • t ORIGINAL 2. The development of the parcel proposed for development as a comprehensive infill redevelopment project or residential infill project will not reduce the fair market value of abutting properties. (Include the existing value of the site and the proposed value of the site with the improvements.) _--Placing a permanent and more attractive structure on the site will improve the value of the adjacent properties. The facility will ----replace the existing, dated modular building, not adding to the capactity of the facility, but better serve those currently being_served. 3. The uses within the comprehensive infill redevelopment project are otherwise permitted in the City of Clearwater. ____The uses of an Overnight Accomodation are permitted within the Commercial zoning on the property, and the property has been used ____for the same use proposed since 1974. No change in use, density or capactiy is contemplated or proposed. 4. The uses or mix of use within the comprehensive infill redevelopment project are compatible with adjacent land uses. ----The parcels to the North, Northeast, and South are owned by the same entity and the church that sponsors the Homeless Emergency ---Project, and thus compatible. Directly to the east is a substance abuse center and the property has been used for the same use ----proposed since 1974. No change in use, density or capactiy is contemplated or proposed_________--------- -___ 5. Suitable sites for development or redevelopment of the uses or mix of uses within the comprehensive infill redevelopment project are not otherwise available in the City of Clearwater. ____The kitchen and dining facility being replaced serves the residents who reside in the rooms directly surrounding the dining hall and the _--adjacent church. Relocating the kitchen and dining hall to a remote location would not be practical operationally for the Homeless _--Emergency Project and would therefore be counter to the self-contained range of services offered by the organization----_-_ 6. The development of the parcel proposed for development as a comprehensive infill redevelopment project will upgrade the immediate vicinity of the parcel proposed for development. ___The proposed enhancements bring significant improvement in the character and experience of the community, as it provides for a ___permanent, more aesthetically appealing structure than currently exists.----_ --- - --Placing a permanent and more attractive structure on the site will improve the value of the adjacent properties.---__ 7. The design of the proposed comprehensive infill redevelopment project creates a form and function that enhances the community character of the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. The design of the structure provides a more uniform frontage on Otis C. Green St. and provides a more appropriate form and scale _-__for the immediate vicinity of the parcel proposed. Utilization of permanent structures which comply with current structural, health, _--and accessibility codes greatly enhances the health, safety, welfare and character of the City of Clearwater. 8. Flexibility in regard to lot width, required setbacks, height and off-street parking are justified by the benefits to community character and the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. ---Although the request does require flexibility in lot width, setbacks and parking and Stormwater requirements, the portions of the _--existing facility which directly affect requirements are not being modified. _--Parallel parking configuration proposed increases traffic safety as a benefit to the immediate vicinity and the-City. - - - - - - - 9. Adequate off-street parking in the immediate vicinity according to the shared parking formula in Division 14 of Article 3 will be available to avoid on-street parking in the immediate vicinity of parcel proposed for development. _--This facility is a part of a larger entity which does provide ample off-street parking on parcels adjacent to this structure and were _--addressed in the previously-submitted and approved MasterPlan. The ability to view this project in light of the varied schedules of _--operations for the different facilities and the unique nature of the residents as opposed to the typical requirements benefits the City greatly. 10. The design of all buildings complies with the Tourist District or Downtown District design guidelines in Division 5 of Article 3 (as applicable). Use separate sheets as necessarv. _-__Not Applicable r7 --4! b 12 2005 PLANNING& CITY Cl,I: C LE. Page 3 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater • 10 ORIGINAL E. STORMWATER PLAN SUBMITTAL REQUIREMENTS: (City of Clearwater Storm Drainage Design C Manual and 4-202.A.21) A STORMWATER NARRATIVE MUST BE SUBMITTED WITH ALL APPLICATIONS. All applications that involve addition or modification of impervious surface, including buildings, must include a stormwater plan that demonstrates compliance with the City of Clearwater Storm Drainage Design Criteria manual. A reduction in impervious surface area does not qualify as an exemption tc this requirement. If a plan is not required, the narrative shall provide an explanation as to why the site is exempt. ® At a minimum, the STORMWATER PLAN shall include the following: _xx_ Existing topography extending 50 feet beyond all property lines; (existing to remain, unchanged) _xx_ Proposed grading including finished floor elevations of all structures; (to match existing) _xx_ All adjacent streets and municipal storm systems; (existing to remain, unchanged) _xx_ Proposed stormwater detention/retention area including top of bank, toe of slope and outlet control structure _xx_ A narrative describing the proposed stormwater control plan including all calculations and data necessary to demonstrate compliance with the City manual. (Narrative is attached; calculations are indicated on the Drawings.) N/A Signature and seal of Florida Registered Professional Engineer on all plans and calculations. (not required - per Staff) © COPY OF PERMIT INQUIRY LETTER OR SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT (SWFWMD) PERMIT SUBMITTAL (SWFWMD approval is required prior to issuance of City Building Permit), if applicable (not applicable) IT Acknowledgement of stormwater plan requirements (Applicant must initial one of the following): Stormwater plan as noted above is included _ IFS-. __ Stormwater plan is not required and explanation narrative is attached. At a minimum, a grading plan and finished floor elevations shall be provided. CAUTION - IF APPLICATION REVIEW RESULTS IN THE REQUIREMENT FOR A STORMWATER PLAN AND NONE HAS BEEN SUBMITTED, APPLICATION MUST BE RESUBMITTED AND SIGNIFICANT DELAY MAY OCCUR. If you have questions regarding these requirements, contact the City Public Works Administration Engineering Department at (727) 562-4750. F. SUPPLEMENTAL SUBMITTAL REQUIREMENTS: (Code Section 4-202.A) IF] SIGNED AND SEALED SURVEY (including legal description of property) - One original and 14 copies submitted previously; I] TREE SURVEY (including existing trees on site and within 25' of the adjacent site, by species, size (DBH 4" or greater), and location, including drip lines and indicating trees to be removed) - please design around the existing trees; (not applicable - no trees on site) © LOCATION MAP OF THE PROPERTY; N/A PARKING DEMAND STUDY in conjunction with a request to make deviations to the parking standards lie. Reduce number of spacesl. Prior to the submittal of this application, the methodology of such study shall be approved by the Community Development Coordinator and shall be in accordance with accepted traffic engineering principles. The findings of the study will be used in determining whether or not deviations to the parking standards are approved; (not applicable - does not change current MasterPlan on file with City) N/A GRADING PLAN, as applicable; N/A PRELIMINARY PLAT, as required (Note: Building permits will not be issued until evidence of recording a final plat is provided); N/A COPY OF RECORDED PLAT, as G. SITE PLAN SUBMITTAL REQUIREMENTS: (Section 4-202.A) © SITE PLAN with the following information (not to exceed 24" x 36"): r -, _x_ All dimensions; f a i j .7 I, _x_ North arrow; Engineering bar scale (minimum scale one inch equals 50 feet), and date prepared; i _x_ Location map; _x_ Index sheet referencing individual sheets included in package; ?u?? _x_ Footprint and size of all EXISTING buildings and structures; _x_ Footprint and size of all PROPOSED buildings and structures; _x_ All required setbacks; CANNING & DE'VI?$ _x_ All existing and proposed points of access; _x_ All required sight triangles; _x_ Identification of environmentally unique areas, such as watercourses, wetlands, tree masses, and specimen trees, including description and location of understory, ground cover vegetation and wildlife habitats, etc; -x_ Location of all public and private easements; _x_ Location of all street rights-of-way within and adjacent to the site; Page 4 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater i r-l _x_ Location of existing public and private utilities, including fire hydrants, storm and sanitary sewer lines, manholes and lift stations, gas and water lines; _x_ All parking spaces, driveways, loading areas and vehicular use areas; _x_ Depiction by shading or crosshatching of all required parking lot interior landscaped areas; _x_ Location of all solid waste containers, recycling or trash handling areas and outside mechanical equipment and all required screening (per Section 3-201(D)(i) and Index #7011; _x_ Location of all landscape material; _x_ Location of all onsite and offsite storm-water management facilities; _x_ Location of all outdoor lighting fixtures; and _x_ Location of all existing and proposed sidewalks. ? SITE DATA TABLE for existing, required, and proposed development, in written/tabular form: _x_ Land area in square feet and acres; _x_ Number of EXISTING dwelling units; _x_ Number of PROPOSED dwelling units; _x_ Gross floor area devoted to each use; _x_ Parking spaces: total number, presented in tabular form with the number of required spaces; _x_ Total paved area, including all paved parking spaces and driveways, expressed in square feet and percentage of the paved vehicular area; _x_ Size and species of all landscape material; _x_ Official records book and page numbers of all existing utility easement; Building and structure heights; Impermeable surface ratio (I.S.R.); and N/A Floor area ratio (F.A.R.) for all nonresidential uses. ? REDUCED SITE PLAN to scale (8 '/3 X 11) and color rendering if possible; ? FOR DEVELOPMENTS OVER ONE ACRE, provide the following additional information on site plan: N/A One-foot contours or spot elevations on site; N/A Offsite elevations if required to evaluate the proposed stormwater management for the parcel; N/A All open space areas; N/A Location of all earth or water retaining walls and earth berms; N/A Lot lines and building lines (dimensioned); N/A Streets and drives (dimensioned); N/A Building and structural setbacks (dimensioned); NIA Structural overhangs; N/A Tree Inventory; prepared by a "certified arborist", of all trees 8" DBH or greater, reflecting size, canopy (drip lines) and condition of such trees. H. LANDSCAPING PLAN SUBMITTAL REQUIREMENTS: (Section 4-1102.A) O LANDSCAPE PLAN: _x_ All existing and proposed structures; _x_ Names of abutting streets; _x_ Drainage and retention areas including swales, side slopes and bottom elevations; _x_ Delineation and dimensions of all required perimeter landscape buffers; _x_ Sight visibility triangles; _x_ Delineation and dimensions of all parking areas including landscaping islands and curbing; _x_ Proposed and required parking spaces; _x_ Existing trees on-site and immediately adjacent to the site, by species, size and locations, including driplines (as indicated on required tree survey); _x_ Plant schedule with a key (symbol or label) indicating the size, description, specifications and quantities of all existing and proposed landscape materials, including botanical and common names; _x_ Location, size, and quantities of all existing and proposed landscape materials, indicated by a key relating to the plant schedule; _x_ Typical planting details for trees, palms, shrubs and ground cover plants including instructions, soil mixes, backfilling, mulching and protective measures; _x_ Interior landscaping areas hatched and/or shaded and labeled and interior landscape coverage, expressing in both square feet and percentage covered; _x_ Conditions of a previous development approval (e.g. conditions imposed by the Community Development Board); (on file) _x_ Irrigation notes. ? REDUCED LANDSCAPE PLAN to scale (8'/z X 11) (color rendering if possible); © IRRIGATION PLAN (required for level two and three approval); (Fully irrigated - provided as design-build system, see notes on dwgs) O COMPREHENSIVE LANDSCAPE PROGRAM application, as applicable. Landscape associated with the Comprehensive Landscape Program shall exceed minimum Code requirements to offset the areas where minimum Code will not be met. 1 2 2035 1 Page 5 of 7 - Flexible Development Comprehensive Infill Application 2005- City r f 1. BUILDING ELEVATION PLAN SUBMITTAL REQUIREMENTS: (Section 4-202.A.23) Required in the event the application includes a development where design standards are in issue (e.g. Tourist and Downtown Districts) or as part of a Comprehensive Infill Redevelopment Project or a Residential Infill Project. ? BUILDING ELEVATION DRAWINGS -all sides of all buildings including height dimensions, colors and materials; 0 REDUCED BUILDING ELEVATIONS - four sides of building with colors and materials to scale (8'% X 11) (black and white and color rendering, if possible) as required. J. SIGNAGE: (Division 19. SIGNS / Section 3-1806) O All EXISTING freestanding and attached signs; Provide photographs and dimensions (area, height, etc.), indicate whether they will be removed or to remain. N/A All PROPOSED freestanding and attached signs; Provide details including location, size, height, colors, materials and drawing; freestanding signs shall include the street address (numerals) (J r N/A Comprehensive Sign Program application, as applicable (separate application and fee required). I 1 ' ' ?`,i? N/A Reduced signage proposal (8'/2 X 11) (color), if submitting Comprehensive Sign Program application. J I ':d K. TRAFFIC IMPACT STUDY: (Section 4-202.A.13 and 4-801.C) / ?- -°°----•-«?-- PLAIdtriNG & 0EVEL0F_M.Zr N/A Include if required by the Traffic Operations Manager or his/her designee or if the proposed development: CITY • Will degrade the acceptable level of service for any roadway as adopted in the Comprehensive Plan. • Will generate 100 or more new vehicle directional trips per hour and/or 1000 or more new vehicle trips per day. • Will affect a nearby roadway segment and/or intersection with five (5) reportable accidents within the prior twelve (12) month period or that is on the City's annual list of most hazardous intersections. Trip generation shall be based on the most recent edition of the Institute of Transportation Engineer's (ITE) Trip General Manual. The Traffic Impact Study must be prepared in accordance with a "Scoping Meeting" held with the Traffic Operations Manager and the Planning Department's Development Review Manager or their designee (727-562-4750) Refer to Section 4-801 C of the Community Development Code for exceptions to this requirement. ?O Acknowledgement of traffic impact study requirements (Applicant must initial one of the following): Traffic Impact Study is included. The study must include a summary table of pre- and post-development levels of service for all roadway legs and each turning movement at all intersections identified in the Scoping Meeting. __SBL - Traffic Impact Study is not required. (Project replaces the existing, dated modular building, not adding to the capactity of the facility CAUTION - IF APPLICATION REVIEW RESULTS IN THE REQUIREMENT FOR A TRAFFIC IMPACT STUDY AND NONE HAS BEEN SUBMITTED, APPLICATION MUST BE RESUBMITTED AND SIGNIFICANT DELAY MAY OCCUR. If you have questions regarding these requirements, contact the City Public Works Administration Engineering Department at (727) 562-4750. L. SIGNATURE: I, the undersigned, acknowledge that all representations made in this application are true and accurate to the best of my knowledge and authorize City representatives to visit and photograph the property described in this application. .%,Jaltte Carol Smith : Commission # DD358478 '5tur e roperty own &Q?gep= a li ber 27, 2008 Troy Fein - hunra•, im. 80a VW019 STATE OF FLORIDA, COUNTY OF PINELLAS M Swoy? to and subscribed before me this day of ?___ A.D. 200y- to me and/or by ew_??$FFEIe'Tywho is ersonally kno has produced as 'y public- commission expires: Affidavit To Authorize Agent on file - Submitted with previous submittal package. S1_ Page 6 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater • • Homeless Emergency Project Inc. ORIGINAL Comprehensive Infill ReDevelopment Project Application Attachment "A" (Revised 8/12/05) Description of Request(s): Comprehensive Infill Redevelopment Project review, Level 3, of a parcel that is currently non- conforming to provide aesthetic improvements and to replace an existing, outdated modular structure with a lower-scale, permanent structure. Existing setback conditions and density to remain unchanged. This facility will not increase the density of the development or provide additional services, but will provide better service to those clients and residents already being served by the existing facilities. Significant improvement in aesthetics, parking layout, stormwater treatment, solid waste collection and landscaping are proposed. This submittal is being accompanied by Comprehensive Landscape plan submittal. The current facility was constructed in approximately 1972, in compliance with zoning ordinances at the time. The Dining Hall and Kitchen, a modular structure was installed in 1974 and does not meet current wind load requirements. Adoption of ordinances subsequent to the property's construction has deemed the property non-compliant in the following: Parking: Flexibility consideration is being requested to Parking Requirements (Clearwater Development Code Part 1, Section 2-702) which requires 1 parking space per Unit. The Residential Shelter facility (classified Overnight Accommodation) provides 18 units, which would require 18 parking spaces. Currently 2 parking spaces exist and the proposed project provides for 1 disabled parking space and 1 loading space in a parallel parking configuration adjacent to the existing curb. Comprehensive Infill Redevelopment Projects do not have a specific parking requirement for Comprehensive InFill Projects according to Clearwater Development Code Part 1, Section 2-704.C.8 and Table 2-704. A previous MasterPlan study conducted by Wade-Trim, Inc. earlier in 2005 encompassed the facilities shared by the Homeless Emergency Project, Inc. and Everybody's Tabernacle which provided an overall parking and drainage study. This Project will not provide any change to the studies already performed and approved. The unique service this facility provides for the previously homeless requires no parking for the residential use, as the homeless do not generally possess vehicles. One staff member is required for operation of the kitchen facilities; that staff member parks in the church parking lot to the south. One staff member is required for operation of the residential shelter facilities; that staff member resides in a single family residence owned by the Church/Homeless Emergency Project on adjacent Fairburn Street and walks to work. No permanent parking is required for this unique facility. Existing parking is partially on public rights of way, requiring backing out onto the street, with no land available for on site parking. One disabled parking space is being provided for the convenience of those visiting the facility. One loading space is being provided for deliveries. Proposed parking layout is revised to eliminate the backing out onto the Street, as recommended by Staff. Landscaping: Due to the fact that there is little on site parking, no interior landscaping is provided at parking areas, but is provided surrounding it. The proposed plan significantly improves landscaping and utilizes a number of native, low maintenance and drought-tolerant species in the design. A comprehensive landscaping application is being made concurrently with this application. O 47 d'' ° A US t 2 2035 I PLANN,NG g DF CITY CAF C. F. .'_:' ORIGINAL Setbacks: (Clearwater Development Code Part 1, Section 2-702 & 704) South (Front): The existing facility provides a front setback of 4.3 and 4.7 feet for widths of 24.7 feet at the each wing. Proposed setbacks would remain as existing at the wings, and the new structure is set back 25' from the Property Line, conforming to current requirements, which require a 25' front setback. Flexibility is being requested to construct a required dumpster enclosure 4.5' from the property line, aligning with the face of existing buildings, which provides for a more uniform frontage on the property and enhanced aesthetics due to the screening of the solid waste. Setbacks are Not Applicable for Comprehensive Infill ReDevelopment Projects for Comprehensive InFill Projects according to Clearwater Development Code Part 1, Section 2-704.K.6 and Table 2-704. North (Rear): The existing structure provides setbacks of 0.6 Feet to 1.7 Feet. This would remain unchanged. Current codes require 10' - 20' setbacks for Flexible Development, but setbacks are Not Applicable for Comprehensive Infill ReDevelopment Projects for Comprehensive InFill Projects according to Clearwater Development Code Part 1, Section 2- 704.K.5 and Table 2-704. West Side (Side): The existing structure provides a setback of 0.6 Feet. This would remain unchanged. Current codes require 0'-10' setbacks for Flexible Development, but setbacks are Not Applicable for Comprehensive Infill ReDevelopment Projects for Comprehensive InFill Projects according to Clearwater Development Code Part 1, Section 2- 704.K.5 and Table 2-704. East Side (Side): The existing structure provides a setback of 5.3 feet to the Property line with approximately 2 more feet to the sidewalk. This would remain unchanged. Current codes require 0'-10' setbacks for Flexible Development, but setbacks are Not Applicable for Comprehensive Infill ReDevelopment Projects for Comprehensive InFill Projects according to Clearwater Development Code Part 1, Section 2-704.K.5 and Table 2-704. Density: The existing facility, an Overnight Accommodation provides for 18 units on .43 acres, or approximately 42 units per acre. The use and density would remain unchanged. Countywide Future Land Uses provide for a development potential of 10 - 24 units per acre for corresponding Future Land Use Designations. Flexibility is being requested to Clearwater Development Code Part 1, Section 2-701 according to Section 2-704.C.1-6. Lot Size: The existing lot is 125.03' wide by 150' deep with a total lot area of 18,754 Square Feet. Clearwater Development Code Part 1, Section 2-702 requires a minimum lot width of 200' and minimum lot area of 40,000 Square Feet. Flexibility is requested to this requirement. No minimum lot area is required for Comprehensive InFill Projects according to Clearwater Development Code Part 1, Section 2-704.C.7 and 2-704.K.1 and Table 2-704. Pervious Areas: Currently the courtyard of the facility is 100% covered with buildings, asphalt and concrete, with the only significant pervious area on the east side and in front of the two wings to the south (front). The proposed design adds pervious area in the form of landscaped planting areas and a significant area of concrete pavers (semi-pervious) and a landscaped drainage swale to the south. All drainage currently is surface drainage to the south and the proposed project will utilize gutters and surface drainage in the same direction and manner as existing. Stormwater treatment is being provided in accordance with City of Clearwater Storm Drainage Design Criteria redevelopment guidelines. Drainage Narrative: The site has been in its current configuration since 1974 and all existing stormwater currently drains to the south, out of the courtyard and into city stormwater systems. The current site, less than 1/2 of one acre does not drain on to adjacent properties, retard, accelerate or divert water flow or prohibit proper maintenance, and t ere-ismot,a- current flooding problem immediately surrounding the site. 2i„5 J PGA.°J ?,_._...._ _..? ?J 0 ORIGINAL The proposed project will not exacerbate existing stormwater conditions in the area, nor contribute to an existing flooding problem. The proposed design will utilize roof gutters and a more effective series of surface drainage slopes, which will provide a more directed and deliberate surface drainage systems that currently exists, furthering the safety and quality of the stormwater drainage. Stormwater treatment is being provided in accordance with City of Clearwater Storm Drainage Design Criteria redevelopment guidelines. Appropriate splash blocks, rip-rap or similar treatment will be provided where necessary in order to avoid wash- outs. Due to the limited area of the site and the limited widths of the existing setbacks, the addition of any effective attenuation of stormwater is infeasible. Payment into the City fund is proposed in lieu of providing attenuation. Stormwater management calculations are indicated on the Drawings. A previous MasterPlan study conducted by Wade-Trim, Inc. earlier in 2005 encompassed the facilities shared by the Homeless Emergency Project, Inc. and Everybody's Tabernacle which provided an overall parking and drainage study. This Project will only enhance the studies already performed and approved. 1116 2?v5 ILI PLANNIi G & DEVE {}r,=NJ SVCS CITY 0 9 Homeless Emergency Shelter Kitchen Addition ORIGINAL Comprehensive Infill ReDevelopment Project Application SITE DATA Existing Land Area In Square Feet And Acres: 18,754 Square Feet 0.43 Acres Required Lot Area: 40,000 Square Ft 0.92 Acres No Minimum Lot Size req'd for Comp. Infill Projects Number Of Existing Dwelling Units: Number Of Proposed Dwelling Units Gross Floor Area Devoted To Each Use: Overnight Accommodation: Kitchen & Dining Area: 18 Units 18 Units KPLAN 12 Ex isting Proposed 8750 sf 8750 sf NGDE„c 2020 sf 4003 sf -?? + (NOTE: Kitchen & Dining are an accessory use, supporting the Overnight Accommodation use) Parking Spaces: Existing: 2 Proposed: 2* Required: 18** * 2 disabled parking spaces and 2 loading spaces to be provided. ** Parking concerns were addressed with overall master site plan review in April 2005. This facility is replacing an existing, ancillary facility to the Overnight Accommodation use and does not add to the use of the facility, but enhances the ability to provide services to the existing population of sheltered residents. No specific parking requirements required for Comprehensive Infill Projects. The unique service this facility provides for the previously homeless requires no parking for the residential use, as the homeless do not generally possess vehicles. One staff member is required for operation of the kitchen facilities; that staff member parks in the church parking lot to the south. One staff member is required for operation of the residential shelter facilities; that staff member resides in a single family residence owned by the Church/Homeless Emergency Project on adjacent Fairburn Street and walks to work. No permanent parking is required for this unique facility. Land Use Data: Existing Proposed Required Total Paved Area (parking area): 908 sf 726 sf Total Paved Area (courtyard & walkway areas): 2,501 sf 2,312 sf Building Coverage: 10,770 sf 12,753 sf Total Impervious Area: 17,459 sf 17,545 sf Total Pervious Area: 1,295 sf 3,625 sf Impermeable Surface Ratio (I.S.R.)** 0.93 0.79 Building And Structure Heights (1 story): 14' 18' 25-50' Setbacks:** Front (Existing Building) 4.3' 4.3' 25'** Front (Proposed Building) 34.2' 25.2' 25'** Side - West (Existing Building) 0.6' 0.6' 0-101** Side - East (Existing Building) 5.3' 5.3' 0-101** Rear (Existing Building) 0.6' 0.6' 10-20'** Lot Width:** (Existing) 125' 125' 150-200'** **Note: No specific requirements are listed for Comprehensive Infill Projects. Floor Area Ratio (F.A.R.) For All Nonresidential Uses: N/A-Overnight Accommodation 0 0 ORIGINAL Size And Species Of All Landscape Material: See Landscape Plan Official Records Book And Page Numbers Of All Existing Utility Easements: See Survey There are no free-standing signs proposed with this project. One building-mounted sign exists - and shall remain. !e' L IS 12 LVV? ,f i' ` 'r 3 a Q J a T 4 J U 0 d1 COLOR- SILENT YELLOW SWI661 "MATC14 EXISTING" RETURN 5' - 0" AROUND CORNER - COLOR- SILENT , s YELLOW SWI66' ., OUVER CC,_OR- WA'7E TILE ACCEL?010:;' /,2v COLOR GREEN SHINGLES TO MATCH tr S EXISTING BUILDINGS COLOR- SILENT YEL. SWI66i `MATCH EXIST. n RETURN AROUND . J CORNER DECORATIVE SCORING ANDJ APPLIED PILASTERSCOLOF COLOR- FORMAL TILE ACCENTS SWI455 GARDEN SWI455 SPLIT FACE CM COLOR- HORIZONTAL BANDING ECRU W/ WHITE AGREGATE APPLIED CEMENTITIOUS COATING ACCENT BAND ON EXISTING BUILDING PROPOSED SOUTH ELEVATION .? SCALE: 3/32"=V-0" 0 C7 CC-Al 1 _- 0 imater Clearwater, Florida 33756 L Planning and Development Services '.C1 O ? SUBMIT ORIGINAL SIGNED AND NOTARIZED 100 South APPLICATION Myrtle Avenue ? SUBMIT 1 COPY OF THE ORIGINAL APPLICATION including folded site plan Telephone: 727-562-4567 Fax: 727-562-4576 u 'D ORIGINAL CASE #: _FLD2005-07063_ DATE RECEIVED: RECEIVED BY (staff initials): ATLAS PAGE #: _2696 ZONING DISTRICT: _C (Commercial)- LAND USE CLASSIFICATION: ZONING & LAND USE CLASSIFICATION OF ADJACENT PROPERTIES: NORTH: _C (Comm)- SOUTH: _I (Church) _ / _---__- WEST: __C (Comm)- / ----- EAST: __C (Comm)- / COMPREHENSIVE LANDSCAPE PROGRAM REQUIREMENTS (Revised 9/19/2001) D. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4-1001) APPLICANT NAME: _-Homeless Emergency Project MAILING ADDRESS: 1120 N. Betty Lane, Clearwater, Florida PHONE NUMBER: _---_(727) 442-9041_-------- FAX NUMBER: PROPERTY OWNER(S): _-Homeless Emergency Project, (Must include ALL owners) (727) AGENT NAME: (Contact Person) _--_Lafferty ARCHitecture Group LLC (Stephen B. Lafferty, AIA MAILING ADDRESS: _--___----__11414 Seminole Blvd, Suite 5, Largo, FL 33778 PHONE NUMBER: ___727-399-1300FAX NUMBER: _---_-_727-399-5777 111% L The landscaping requirements of Article 3 Division 12 may be waived or modified as a part of a Level One or Level Two Approval, as the case may be, if the application for development approval includes a Comprehensive Landscape Program, which satisfies the following criteria. The use of landscape plans; sections/elevations, renderings and perspectives may be necessary as supplementary information in addition to the information provided on this worksheet: Architectural Theme. a. The landscaping in a Comprehensive Landscape Program shall be designed as a part of the architectural theme of the principal buildings proposed or developed on the parcel proposed for the development. Page 1 of 3 0 0 ORIGINAL b. The design, character, location and/or materials of the landscape treatment proposed in the Comprehensive Landscape Program shall be demonstrably more attractive than landscaping otherwise permitted on the parcel proposed for development under the minimum landscape standards. 2. Lighting. Any lighting proposed as a part of a Comprehensive Landscape Program is automatically controlled so that the lighting is turned off when the business is closed. Ambient lighting is required by the Life Safety Code and the Building Codes in the courtyard and corridor. Accent lighting that is not required by code shall be controlled by photo-cell and by Urneclock to turn off at midnight. Community Character. The landscape treatment proposed in the Comprehensive Landscape Program will enhance the community character of the City of Clearwater. Page 2 of 3 • ORIGINAL 4. Property Values. The landscape treatment proposed in the Comprehensive Landscape Program will have a beneficial impact on the value of the property in the immediate vicinity of the parcel proposed for development. Special Area or Scenic Corridor Plan. The landscape treatment proposed in the Comprehensive Landscape Program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the parcel proposed for development is located. Not pnlicable Please return checklist for review and verification. Date: - ???--- - - < -- (Sign u applicant) S: application forms/development review/comprehensive landscape program application.doc Page 3 of 3 EXISTING OAK TREES ON ADJACENT PROPERTi (TYP OG 4i FLOWERING ANNUALS TO BE PLANTED BY RESIDENTS AT BASE OF PALM TREES, TYP_ n CON:. BLOCK wa Y lam./ ?. Z 2` L-tt L ? + G 1 _ -- L N EXISTING CRAPE MYRTLES ON „ ADJACENT PROPERTY EXISTING /TYP OF 3 BUILDING TO REMAIN M rEXISTING CURB TO REMAIN B SAv EX15TING RETAINING WALL TO REMAIN EXISTING PALM TREE TO REMAIN PROPOSED D 'v V D LANDSCAPE PLAN . V4 ^+ - COLOR- SILEN- YELLOW 5WI66 -? ---OUVER CO-OR- -E _ENT OR* -inn" N? _Iw `c 174... I i b i I c DECORA"VE SCORING ANi COLOR- cOR""A_ TILE ACCENTS J GARDEN 5W1455 5011-17 FACE O"11: COLOR- ECRU UJ/ 4W!TE AGREGATE i CI r--COLOR- GRE 5NINGLE5 P 7r.399-I.IM TO MATC. EXISTING F 'r 399 S^ r tte.col?(EerrvARCH.com '! ^ - CO:-OR- SILENT YELL 11414 Semmole Blvd. Ste 5 I , ' - cJ $Wlbb' "MATG+: Exr5T1 Zb5[J3336614 FL LIC M 26000901 - r RE't1I? _'' dROWC s c .t.ot . CORNER A- 5,49 b,., -:55 -- "ORiZONTAL BANDING AF?_IEC CEMEN-ITIOUS COdT!NG ACCEti' SAND ON EXIS-NG BUILDING PROPOSED SOUTH ELEVATION n ORIGINAL Iz I P! AIvtL'Et?4 GzL%c?i?'rv :- x _ IR 1? Planning and Development Services clearwate ° Fax: 727-562-4576 ? SUBMIT ORIGINAL SIGNED AND NOTARIZED APPLICATION ? SUBMIT 1 COPY OF THE ORIGINAL APPLICATION including folded site plan ORIGINAL CASE #: _ DATE RECEIVED: RECEIVED BY (staff initials): ATLAS PAGE #: ZONING DISTRICT: _ LAND USE CLASSIFICATION: ZONING & LAND USE CLASSIFICATION OF ADJACENT PROPERTIES: NORTH: SOUTH: / WEST: - - / ----- EAST: COMPREHENSIVE LANDSCAPE PROGRAM REQUIREMENTS (Revised 9/19/2001) D. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4-1001) APPLICANT NAME: -Homeless Emergency Project Inc. MAILING ADDRESS: -1120 N. Betty Lane, Clearwater, Florida 33755 PHONE NUMBER: (727) 442-9041_-_ -- FAX NUMBER: --(727) 443-4875_ PROPERTY OWNER(S): _-Homeless Emergency Project, Inc. (Must include ALL owners) AGENT NAME: (Contact Person) -__Lafferty ARCHitecture Group LLC (Stephen B. Lafferty, AIA MAILING ADDRESS: PHONE NUMBER: 727-399-1 The landscaping requirements of Article 3 Division 12 may be waived or modified as a part of a Level One or Level Two Approval, as the case may be, if the application for development approval includes a Comprehensive Landscape Program, which satisfies the following criteria. The use of landscape plans; sections/elevations, renderings and perspectives may be necessary as supplementary information in addition to the information provided on this worksheet: Architectural Theme. a. The landscaping in a Comprehensive Landscape Program shall be designed as a part of the architectural theme of the principal buildings proposed or developed on the parcel proposed for the development. 4 ?100 South Clearwater, Myrtle Avenue Florida 33756 Telephone: 727-562-4567 11414 Seminole Blvd, Suite 5, Largo, FL 33778 FAX NUMBER: _--_-_727-399-5777. Page 1 of 3 OR lJRIGINAI b. The design, character, location and/or materials of the landscape treatment proposed in the Comprehensive Landscape Program shall be demonstrably more attractive than landscaping otherwise permitted on the parcel proposed for development under the minimum landscape standards. 2. Lighting. Any lighting proposed as a part of a Comprehensive Landscape Program is automatically controlled so that the lighting is turned off when the business is closed. 3. Community Character. The landscape treatment proposed in the Comprehensive Landscape Program will enhance the community character of the City of Clearwater. RECEIVED .11.1 11 2005 PLANNING DEPARTMENT CITY OF CLEARWATER Page 2 of 3 • WRIGINAL 4. Property Values. The landscape treatment proposed in the Comprehensive Landscape Program will have a beneficial impact on the value of the property in the immediate vicinity of the parcel proposed for development. 5. Special Area or Scenic Corridor Plan. The landscape treatment proposed in the Comprehensive Landscape Program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the parcel proposed for development is located. Not Applicable RECEIVED JUL 11 2005 Please return checklist for review and verification. Date: I , PUNNING DEPARTMENT C Y OF OLEARWATER (Signature of applicant) S: application forms/development review/comprehensive landscape program application.doc Page 3 of 3 Q d V N COLOR- SILENT YELLOW 5WI661 TIATCH EXISTING" RETURN AROUND CORNER COLOR-FORMAL GARDEN SW1455 SPLIT FADE L;MU GVLVK- ECRU W/ WHITE AGREGATE COATING ACCENT BAND ON EXISTING BUILDING PROPOSED SOUTH ELEVATION SCALE: 3/32"=1'-0" COLOR GREEN 5,4INGLE5 TO MATCH EXISTING BUILDINGS - SILENT YEL, "MATCH EXIST, O V /eJ Stephen B. Lrffcrt), ALA Lffe , Arduteaua Group P 727-399-1300 F 727-399-577^ -. 1-ff"ARCH.- 11414 Seminole Blvd, Ste 5 Largo, FL 33778 AR 17265, ID 3614 FL UC AA 26WO901 0 2004 all rights reaaved z Q e O 0 z e ? z o zQ w ? e e l l W a W Wx w o ww ° CO s .. xw C U U w 2 (? i0 O ? 4 C U ? ?C. D !y CD SECTION 10, TOWNSHIP 29 SOUTH, RANGE 15 EAST PINELLAS COUNTY, FLORIDA LOT 4 BLOCK C ' LOT 5 BLOCK C LOT 6 BLOCK C ,t V LOT (0 BLOCK C N 99?9'1J' E (Y) ISSOJ' (YJ u.u r (. LOT 9 s*wr nrm?uswr auiasc BLOCK C now ncv.. (ss i Lar e BLOCK C PROPOSED R y? BUILDING ' 9 LOT 7 $ BLOCK C 8 naw .` wsvv a` ni (q ` s /1 o.i.L. .v w9 LBSAAE ST. --.-'---'---'-'-'-'---'€--w:o-son U K ??ON 5.4 a s, M ? ?Y d4i ?wW? /1r w?a ?t?1 ? 17 r ??? M Ihi p? IYII? JUL 11 2005 PANNING DEPARTMENT CfiYOF CLEARWATER s S C7 4s n.o. I .`'? ,p0.orts ln???ncv.nw ?SYn 4ww„wxctf [nsnn r?s.w a s. wv. nsv. - s.u ."' omo9s . vw, m¢ - sn r«.sm 9` ocworzs a snuw. ? _ 9rz ouurzo •f wo?uo ins?o'vmi ? ?• •eoc nR i Yemenm scassc LeNeay as:nnen:w.e Droop L.L.C. P 727•31I.I.- f 727.399•!777 Info4DL10er1yABCN.eom /tsls Seminole Blyd, 6le ! Large, FL 33779 FL LIC AA2600901 rz WQw0 a wx U) W G L?j PC) {1] p: ? ?C xW J x Stephan 6. L6Merty, A111 FL Lle AR12265, 5,103614 SURVEY Pr9?.c1IF L05-29 7-m "C-10i Al 4NaW RECHVED ORIGINAL JUL 11 205 EXISTING P~ BUILDING - ^LVWJ%PllO- EXISTING WEST VIEW (UNCHANGED) SCALE: KT5. COLOR- SILENT YELLOW SILI661- COLOR- SILENT YELLOW SWI661 TILE ACCENT TO HATCH 'HATCH EXMTN?' SILENT YELLOW- S 0 RETURN AROUND 3 9 i 9 BU9HE6?? CE IENTITIOUS COATING W/ DECORATIVE SCORING AND COLOR- FORMAL TILE ACCENTS GARDEN SU455 SPLIT FACE CFRI COLOR- ECRU W/ ILHITE AGREGATE EXISTING NORTHEAST VIEW (UNCHANGED) SCALE: KT5. LOUVER COLOR- WHITE COLOR- GREEN ASPHALT SPNJ ES COLOR- SILENT TELLOW SW661 ? BASHES , APPLIED PILASTERS HORIZONTAL BANDING APPLIED CEMENTITIOUS COATING ACCENT BAND ON EXISTING BUILDING PROPOSED SOUTH ELEVATION 51-ALE:/B'•I'-0" 9 0' WALK 1 i / -. ' W PROPOSED BUILD FIN FLR TO .` HATCH EXISTING r13b5') X11 ti :.>i?n? ___ _ amlNUU-x. wcY PAR4aG ra if?nH ? Ariee o . ? . t P4.xng 0TIS C. CRE?'N Sr. (formerly LaSALLE ST. n•Pmx :,. aoan vex a.n PROPOSED ARCHITECTURAL SITE PLAN SCALE: 1'•20'-0' RF DATA 0 20 40 80 Edstlrp Land Area In Square Feet And Aces: 18,154 Sgwre Faet 0.43 Ades F-wmd Lot Area: 20,000-40,000 square N 0.46-0.92 Acres No Minimum Lat Sim nq'd for Comp. MINI Projects Number Of Bdsttng D Nlw Units: IB Units Numbor Of pmposed -offing Units: IB Units Gross Floor Area Ilevotad To Eadl Use: Existlnll Proposed Ovemlght A mmodatlw: 8750 sf 8750 sf COLOR- GREEN ASPHALT loxnen 6 Dining Am.'. 2020 sf 4003 s/ SHMGLE5 (NOTE: 101ohen B Dining are an accessory use, wppordng tie Ovemight / mmodatkm use) Parking Spaces: Existing: 2 on, : 4• M Wmd: IS-- COLOR. SILENILENT ' • 2 disabled parmrg spaces and 2 ladIng spaces to be proNded. YELLOW S I ELL 661 •• Parking .- were addressed with -trall master site &, review In April 2005. TMs fadlily Is mpladng an EXI existing' andllary fadi0y to the Omrnight AceommodaU- =and does not add to the use of the fadliry, list enharas RETURN the aMllty to pmvkle semim to the existing population of :hNtered residem6. ?,.-, s'•0" No spedfic parking requirements required for Comprehensive InOB Pmjects. AROUND C ER lnM Use OMd: 7 R Wretl - Ix f Proposed V .Als- M sf Total Paved Area (pardw ame): Total Paved Area (courtyard & walkway areas): 2,501 if 3,301 sf Building C nag.: 10,770 sf 12,753 s/ COLOR-FORMAL Total ImperNous Area: 17,459 if 16,%Z sf GARDEN SWI455 Total P-ws Ama: 1,295 sf 1,792 sf Impermeable Surtace Rath (1.5.0.)•• 0.93 0.% \-EXISTNG SIGNAGE Building And Structure Heights (I story): 14' 1" 25-50' TO f3ANN 26 SF 2' X 1 13' . 2 Setbacks:'' Front (Existlnq BWldi)g) 4.3' 4.3' •• 27 Front (Proposed BWMIrg) 34.2' 25.2' 2S•• Sid. -west (Existing BWmlrg) 0.6 0.61 0-10'•• Side - East (Existing BWlding) 5.3 5.3' 0-10••• Mar (Etlsti g Bonding) 0.6' 0.6' 10-20'•• tM WmN:•• (Existing) 125• 125' 150-200'•• ''Note: No spedfic requlremenis are listed for Conn"anstm Infill Pmjeds. Floor Area Ratio (F.A.R.) For An Nanresltlentlal Uses: N/A-0 gat Accommodation Sim and Spades Of All Landsmpe Material: See Lend-ipe an OMdal Records Book And Page Numbers Was Existing Utility Easements: See Survey There are no fine-standing signs proposed wild this pmJect. One building-moumed sign exists - and shall remain. nth AFPhilat'Wya Glad L.L.G. F 727 1300 F 7.7JSFSTTT l a @Lat w12ANg1Amn 11414 Swmna s 111i SW S LnOg, FL 337" R LIC AA2500501 z 0-+ U E d W W?0' W U w w O ra, o p ? N 0 x Stephen B. La l", AIA FL Ue AR122M ID3614 PLAN AND ELEVATIONS l prq«t i L05-29 J 7A9N3 1-A-101 Aa SHOt1N EXISTING EAST ELEVATION (UNCHANGED) SCALE: KT5. ORIGINAL. SHRUB PLANTING DETAIL l'awlL as ?epW aW.l r#aarlawuPmA4D Vagaweo?a,cpaaq ru.pAd..aaapnw...?. eaD RErrD,.E ccaraaeR AERATE EklerM 501E -TMG -1 Y EXISTING OAK TREES ON EXISTING ONC TREES - ON ADJACENT ADJACENT PROPERTY EXISTING PROPERTY ID BUILDING TO o ------- REMAIN --,x ;7-171 7?77 TiOUIERhJG ANNUALS TO I/'?// ?• ?;? '// / //? BE PLANTED RESIDENTS A BY T BASE OF PALM TREES, tYP. / I // 1 LC JR E y'/ 30 LAT IatIL.aP PAD AT Ce4VRr CWTACr . NO NLLe N TIffE IlboD .- 1.. ]• k 4• MADE TP.TJ eP.aCE TIRE eT pw TY- ]'k4'erAl'eml la E -T L" 4• flat aepcER last FaleN aaeoe? TDKL w' mall M aw saxn TIiaK alael2D-a Alb rarrPED ewerac IbIL Em.m aU66RADE CCat TORN Fa:'l1 StL AND-Y6Wi r aeano.n M4oa.:.?.«.w..'r"',w m?i okl?In ltma.L n.,a ?o t«x oTOe,lw..no. .`•n`aauu'°M'T n.?`e°..+.I. ro:..e.,rafl e, n. w,.u,.. vann.?ro.w.» ?..? PLANT MATERIAL LIST Abbrev Common Name Sclenllfie Name 3 MGL Dwarf Magnolla'Llllle Gem" Magnolia grantbgora fill" pem B CP Oueen Palm 5yagrua romanzo/f . 10 LI Crape Mydle Lagersfinemia ladlca 3 CL Areca Palm Chrysalld-,-lulascans RECEVED VG Walt- Viburnum 015- b..1- SAV 6chegelera Vedegated Sche/le/ema roaMCWla-All plats shell be Florlda No I Grade. JUL 11 '205 P MG DEPARTMENT MY OF CLEARWATER Z/x L % / E 7#, F n ? c:},a cx? I t v._ NEW BUILDING TO 3 GL J 510EWALK S S. EXISTING TSAV A S P H A L T D R I V E W A Y 3 VO -1 SAVr 1 SAV Specifications 25 contalner Brown, B' hl., 4' apr., TAI 16 ht. x 5' apr., 50 pal cola 16 M % 64r apr. 6 hl. x Td .pr, -1414 ked 24" hi x IT apr, 3 gal min spaced 30" O.C. 24" hl x 17 apr, 3 Bal min spaced 30' O.C. LaSALLE ST. (MADISON ST. 60' R/W PER PLAT) PROPOSED LANDSCAPE PLAN 9CALEi I".10'-0' PLANTING MATERIAL LIST / I / 0 N W /I T EXISTING TREE TO 60 VO TO II, IB SAV EXISTING RETAINING TO REMAIN r`euenu e L EJUeiPL' iREEe TO 6E i10MgD LID a16apED pD ND dna11 eRANaIEa rob eELOm v -e• aeroyE eRADE. ]. iEItTILI)F A•b'J B4IANGE aLL eE]a Arb E]daiab I'LLITHG AIEb WM PEAT rtOeO A•aJ AP/1R PIwATE I11CN. raErrlo.-E Lr cars=lrr. Deaae. ?II Lalleray .-I1,11 clurc G"u L.L.C. P 2z1-399-upp F 727.399.57" Info®LallertyA6CN.cem 11414 9am11e1. laird, Ste E La,9o, R 33"6 FL uc AAZSppepf z O Q w Q 2zw wu f w V) CID O x slephen B. Laverty, AIA FL Llc A111 Y265, IO7614 la. a.4A. LANDSCAPE: PLAN L05-29 ]hp5 yI. IOI b 644011N r u EXISTING WEST VIEW (UNCHANGED) SCALE: NITS. LOUVER COLOR- WWITE COLOR- SILENT COLOR- GREEN ASPHALT COLOR- GREEN ASPHALT YELLOW 50661 SHINGLES SHINGLES COLOR- SILENT YELL dU 50661 TILE ACCENT TO MATCH COLOR- SILENT YELLOW "MATCH EXISTING" SILENT YELLOW PW"I COLOR- SILENT BUSHES YELLOW 50661 a.,, .. _ '"ATCH EXISTING" RETURN RETURN IRO.ND -ONE ?® CORNER ?15HE5?? TITI0119 COATW, APPLIED PILASTERS ECOR AND ATIVE SCORING AND DECOR COLOR FORHAL COLOR- FnXal'TAL TILE ACCENTS GARDEN 51111455 GARDEN SO4S5 SPLIT FACE COLOR- HORIZONTAL BANDING EC" W/ W}IITE AGREGATE APPLIED GEMENTITIfJUS EXIbTING BIGNAGE COATING ADCENT BAND ON EXISTING BUILDING TO REMAIN TX 13' • 26 SF ?E R PROPOSED SOUTH ELEVATION SCALE: I/e"•I'-0" S r S ORIGINAL EXISTING W-0" WAI BUILDn FIN FLR' MATc EXISfi (13b'. ?V m PROPOSED ARCHITECTURAL SITE PLAN SCALE: I•.20'-0' SITE DATA 0 20 40 80 Edsting Land Area In S9uam Feet And Ades: 18,]54 Square Feet 0.43 - RegWred W Anea: 20,000-40,000 Square R 0.46-0.92 Ayes No Minimum Lot Six reg'd for Camp. Inflll PmJedz Number Of E%I.Ing Dwelling Units: 1B Units Number Of Proposed Dwelling Units: IB Units Gross Floor Arta Devoted To F Use: Edstl Pmosed Ovemght Accammadaten: 87M of 8750d Wed,en B Dining Arta: 2020 d 4003 sf (NOTE: gtmen 5 Dining arc an accessory use, supporting the Ovennight Accommodation use) Pandng Spaces: Existing: 2 Proposed: 4• Rationed: Is- 2 disabled perldng spates and 2 ksadbg spaces W be XeMed. •• Parking cenlcens were addn assed MM overall master site plan nednM In April 2005. Thh facility h replacing an edstlng, ancillary facility to the Ovenllglrt Acmmmodatlon use and does not add to the use of tine facility, but enhances the ability M provide services to the existing populadon of shdtemd residents. No specific par n requirements required for Compm1,endve Infill ProJecx Land Use Data: R,Wmd Paved Area (perldM area): 908 s/ 90 - Total Paved Area (courtyard 5 walkway areas): 2,501 d 3,301 sf Building co"nage: 10,]]0 d 12,]53 sf Total lmpeMous Area: 1],459 d 16,962 sf Total PO - Area. 1,295 sf 1,]92 sf Impemreable Surface Ratio (I.S.R.)•• 0.93 0.90 BWlding And Stnndure Heghts (I stony): 14' 18' 25-50' Setbacks:'- Fmnt(Edstlng Bulging) 4.3' 4.3 25'•• Fmnt (Proposed 8u11ding) 34.2' 25.2' 25'•• Side • West (Existing Bulging) 0.6' 0-30'•• Side -East (Edsting Boding) S.3' S.3' 0-10'•• Reat(Edsun,, BUgdlrg) 0.6' 0.6' 10-20'•• Lot Wdth:•- (Existing) 125' 125' 150-200'-- --Note: No specific regWrements are listed for CompneheDSive Infl11 Projects. Roo, Area Ratio (F.A.R.) For All Nonresidential Uses: N/A-0 gtc Aecommodatlon Sloe And Species Of All Landscape Natenal: See landscape Ran Official Reconds Book And Page Numbers Of All EdsUng Utility Easements: See Survey Them are no fnee-standhg signs pmposcd wIth tills pmject. One building-mounted sign edits - and shall mni8ln. III I.eRMF 4MR LL.C. C. F 73'7.15F1900 F .0"1115777 Inle®1a114r4Ylglsm 11414 SwnkWa Bh4, i to 0 LrSe, n 93775 n ue AAYSW501 z 0 WQWJ wU?? ?I?oPG x Stephan B. t-Sltartl, MA FL Lte A11112265, ID3514 PROPOSED SITE PLAN AND ELEVATIONS Project B L05-29 °` TA9NS -A-101 AS SHdIN ]VIN191dO EXISTING EAST ELEVATION (UNCHANGED) SCALE! N.TS. i # t FLD2005-07063 1200 N BETTY LN Date Received: 07/01/2005 HOMELESS EMERGENCY PROJECT ZONING DISTRICT: C LAND USE: CG ATLAS PAGE: 269B PLANNER OF RECORD: MHR CLW CoverSheet Cleamater Planning Department 100 South Myrtle Avenue Clearwater, Florida 33756 Telephone: 727-562-4567 Fax: 727-562-4865 ORIGINAL • ? SUBMIT ORIGINAL SIGNED AND NOTARIZED APPLICATION ? SUBMIT 14 COPIES OF THE ORIGINAL APPLICATION including 1) collated, 2) stapled and 3) folded sets of site plans ? SUBMIT APPLICATION FEE $1205.00 paid CASE #: --- ------------------ DATE RECEIVED: RECEIVED BY (staff initials): ATLAS PAGE #: ZONING DISTRICT: LAND USE CLASSIFICATION: SURROUNDING USES OF ADJACENT PROPERTIES: NORTH: ------------------- SOUTH: ----------------- WEST: EAST: * NOTE: 15 TOTAL SETS OF INFORMATION REQUIRED (APPLICATIONS PLUS SITE PLAN SETS) FLEXIBLE DEVELOPMENT APPLICATION Comprehensive Infill Project (Revised 12/30/2004) PLEASE TYPE OR PRINT A. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4-202.A) APPLICANT NAME: _-Homeless Emergency Project MAILING ADDRESS: ___1120 N. Betty Lane, Clearwater, Florida PHONE NUMBER: __-(727) 442-9041 --- FAX NUMBER: __--(727) PROPERTY OWNER(S): --Homeless Emergency Project, Inc. -____ (Must include ALL owners as listed on the deed - provide original signature(s) on page 6) H-+ AGENT NAME: --Lafferty ARCHitecture Group LLC / Stephen B. Lafferty, AIA MAILING ADDRESS: ___11414 Seminole Boulevard, Suite 5, Largo, FL 33778 PHONE NUMBER: 727-399-1 CEL L NUMBER: FAX NUMBER: 727-399-5777 E-MAIL ADDRESS: Steve@LaffertyARCH.com B. PROPOSED DEVELOPMENT INFORMATION: (Code Section 4-202.A) STREET ADDRESS of subject site: ___1200 Betty Lane, Clearwater, FL LEGAL DESCRIPTION: _-As noted on the Site Survey (if not listed here, please note the location of this document in the submittal) PARCEL NUMBER: 10 / 29 / 15 / 26550 / 003 / 0070 PARCEL SIZE: _-_.43 Acres _ ------------------------------------- (acres, square feet) PROPOSED USE(S) AND SIZE(S): __Proposed use remains unchaged - Transient Accomodation - 18 units _______ (number of dwelling units, hotel rooms or square footage of nonresidential use) ---This project is to replace the existing dining hall, a Modular Building with a permanent DESCRIPTION OF REQUEST(S): __See Attachment A for additional information. ___--____-_-___--_-____ Attach sheets and be specific when identifying the request (include all requested code deviations; e.g. reduction in required number of parking spaces, specific use, etc.) -Existing parking conditions, density, drainage, setback conditions to remain unchanged, Significant improvement in aesthetics and landscaping. 727-647-8697 ? 00 urns 0 Page 1 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater • ORIGAAL DOES THIS APPLICATION INVOLVE THE TRANSFER OF DEVELOPMENT RIGHTS (TDR), A PREVIOUSLY APPROVED PLANNED UNIT DEVELOPMENT, OR A PREVIOUSLY APPROVED (CERTIFIED) SITE PLAN? YES ___ NO __XX_ (if yes, attach a copy of the applicable documents) C. PROOF OF OWNERSHIP: (Code Section 4-202.A.5) El SUBMIT A COPY OF THE TITLE INSURANCE POLICY, DEED TO THE PROPERTY OR SIGN AFFIDAVIT ATTESTING OWNERSHIP (see page 6) D. WRITTEN SUBMITTAL REQUIREMENTS: (Code Section 3-913.A) O Provide complete responses to the six (6) GENERAL APPLICABILITY CRITERIA- Explain howeach criteria is achieved, in detail: 1. The proposed development of the land will be in harmony with the scale, bulk, coverage, density and character of adjacent properties in which it is located. _-The proposed development will not change the scale, bulk, coverage or density of the site or adjacent properties. -The proposed enhancements bring significant improvement in the character and experience of the community, as it provides for a __permanent, more aesthetically appealing structure than currently exists _ The proposed development will not hinder or discourage the appropriate development and use of adjacent land and buildings or significantly impair the value thereof. _The proposed development will encourage the improvement of adjacent land and buildings by adding to the appearance. ---Placing a permanent and more attractive structure on the site will improve the value of the adjacent properties. The facility will --replace the existing, dated modular building, not adding to the capactity of the facility, but better serve those currently being served. 3. The proposed development will not adversely affect the health or safety or persons residing or working in the neighborhood of the proposed use. ____The proposed project will signicantly improve the health and safety of persons residing or working the the neighborhood, as the facility will be designed to current building and life safety codes and will increase accessiblity to disabled persons .-_______--______ 4. The proposed development is designed to minimize traffic congestion. ___The proposed development will not affect traffic patterns, as the use and traffic concerns will remain unchanged. __The existing site is extremely constrained, and no feasible opportunities are provided to enhance parking conditions bond ----what exists currently 5. The proposed development is consistent with the community character of the immediate vicinity of the parcel proposed for development. _____See response to number 1 The new structure will be surrounded by the existing structure on 3 of 4 6. The design of the proposed development minimizes adverse effects, including visual, acoustic and olfactory and hours of operation impacts, on adjacent properties. ___The proposed design enhances the visual appearance considerably, and enhanced landscaping and front elevation treatment will ----improve acoustic and olfactory concerns. A below ground grease interceptor will also replace an above-ground fixture, adding-to _ -----sanitary safety. Operational hours may be shortened due to the ability to feed more persons in one sitting.___ 21 Provide complete responses to the ten (10) COMPREHENSIVE INFILL REDEVELOPMENT PROJECT CRITERIA (as applicable) - Explain how each criteria is achieved in detail: 1. The development or redevelopment of the parcel proposed for development is otherwise impractical without deviations from the use, intensity and development standards. ____The current dining & cooking facilities, a modular building which no longer complies with current codes, are ageing to the point where it is no ____longer financially viable to maintain and upgrade the structures in their current configuration. In order to properly (and better) serve those ----currently being served, a new structure must be built. The residential rooms surround the site on 3 sides and are not being modified Page 2 of 7 - Flexible Development Comprehensive Inf ill Application 2005- City of Clearwater 0 ORIJNAL 2. The development of the parcel proposed for development as a comprehensive infill redevelopment project or residential infill project will not reduce the fair market value of abutting properties. (Include the existing value of the site and the proposed value of the site with the improvements.) ----Placing a permanent and more attractive structure on the site will improve the value of the adjacent properties. The facility will ----replace the existing, dated modular building, not adding to the capactity of the facility, but better serve those currently being served. 3. The uses within the comprehensive infill redevelopment project are otherwise permitted in the City of Clearwater. ____The uses of an Overnight Accomodation are permitted within the Commercial zoning on the property, and the property has been used ___for the same use proposed since 1974. No change in use, density or capactiy is contemplated or proposed. 4. The uses or mix of use within the comprehensive infill redevelopment project are compatible with adjacent land uses. The parcels to the North, Northeast, and South are owned by the same entity and the church that sponsors the Homeless Emergency ----Project, and thus compatible. Directly to the east is a substance abuse center and the property has been used for the same use ....proposed since 1974. No change in use, density or capactiy is contemplated or 5. Suitable sites for development or redevelopment of the uses or mix of uses within the comprehensive infill redevelopment project are not otherwise available in the City of Clearwater. __-The kitchen and dining facility being replaced serves the residents who reside in the rooms directly surrounding the dining hall and the adjacent church. Relocating the kitchen and dining hall to a remote location would not be practical operationally for the Homeless ----Emergency Project and would therefore be counter to the self-contained range of services offered by the organization_ 6. The development of the parcel proposed for development as a comprehensive infill redevelopment project will upgrade the immediate vicinity of the parcel proposed for development. ____The proposed enhancements bring significant improvement in the character and experience of the community, as it provides for a ....permanent, more aesthetically appealing structure than currently Placing a permanent and more attractive structure on the site will improve the value of the adjacent proAerties. 7. The design of the proposed comprehensive infill redevelopment project creates a form and function that enhances the community character of the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. The design of the structure provides a more uniform frontage on Otis C. Green St. and provides a more appropriate form and scale _____for the immediate vicinity of the parcel proposed. Utilization of permanent structures which comply with current structural, health, ____and accessibility codes greatly enhances the health, safety, welfare and character of the City of Clearwater. 8. Flexibility in regard to lot width, required setbacks, height and off-street parking are justified by the benefits to community character and the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. _--Although the request does require flexibility in lot width, setbacks and parking, the portions of the existing facility which directly affect ____requirements are not being modified. 9. Adequate off-street parking in the immediate vicinity according to the shared parking formula in Division 14 of Article 3 will be available to avoid on-street parking in the immediate vicinity of parcel proposed for development. ----This facility is a part of a larger entity which does provide ample off-street parking on parcels adjacent to this structure and were ----addressed in the previously-submitted and approved MasterPlan. The ability to view this project in light of the varied schedules of operations for the different facilities and the unique nature of the residents as opposed to the typical requirements benefits the City greatly. 10. The design of all buildings complies with the Tourist District or Downtown District design guidelines in Division 5 of Article 3 (as applicable). Use separate sheets as necessary. Not JUL --------- --- -- - PLANNING DEPARTMENT Page 3 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Cle aDYC' CLEARWATER 0 ORIGINAL E. STORMWATER PLAN SUBMITTAL REQUIREMENTS: (City of Clearwater Storm Drainage Design Crite Manual and 4-202.A.21) A STORMWATER NARRATIVE MUST BE SUBMITTED WITH ALL APPLICATIONS. All applications that invoh addition or modification of impervious surface, including buildings, must include a stormwater plan that demonstrates compliance with tt City of Clearwater Storm Drainage Design Criteria manual. A reduction in impervious surface area does not qualify as an exemption this requirement. If a plan is not required, the narrative shall provide an explanation as to why the site is exempt. 0 At a minimum, the STORMWATER PLAN shall include the following: _xx_ Existing topography extending 50 feet beyond all property lines; (existing to remain, unchanged) _xx_ Proposed grading including finished floor elevations of all structures; (to match existing) -xx_ All adjacent streets and municipal storm systems; (existing to remain, unchanged) N/A Proposed stormwater detention/retention area including top of bank, toe of slope and outlet control structure; (not required) N/A A narrative describing the proposed stormwater control plan including all calculations and data necessary to demonstrate compliance with the City manual. (Narrative is attached; calculations not required; existing to remain, unchanged) N/A Signature and seal of Florida Registered Professional Engineer on all plans and calculations. (not required) n COPY OF PERMIT INQUIRY LETTER OR SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT (SWFWMD) PERMIT SUBMITTAL (SWFWMD approval is required prior to issuance of City Building Permit), if applicable (not applicable) El Acknowledgement of stormwater plan requirements (Applicant must initial one of the following): ____ Stormwater plan as noted above is included _SBL _ Stormwater plan is not required and explanation narrative is attached. At a minimum, a grading plan and finished floor elevations shall I: provided. CAUTION - IF APPLICATION REVIEW RESULTS IN THE REQUIREMENT FOR A STORMWATER PLAN AND NONE HAS BEEN SUBMITTED, APPLICATION MUST BE RESUBMITTED AND SIGNIFICANT DELAY MAY OCCUR. If you have questions regarding these requirements, contact the City Public Works Administration Engineering Department at (727) 562-4750. F. SUPPLEMENTAL SUBMITTAL REQUIREMENTS: (Code Section 4-202.A) ? SIGNED AND SEALED SURVEY (including legal description of property) - One original and 14 copies; O TREE SURVEY (including existing trees on site and within 25' of the adjacent site, by species, size (DBH 4" or greater), and location, including drip lines and indicating trees to be removed) - please design around the existing trees; (not applicable - no trees on site) ?x LOCATION MAP OF THE PROPERTY; N/A PARKING DEMAND STUDY in conjunction with a request to make deviations to the parking standards lie. Reduce number of spaces). Prior to the submittal of this application, the methodology of such study shall be approved by the Community Development Coordinator and shall be in accordance with accepted traffic engineering principles. The findings of the study will be used in determining whether or not deviations to the parking standards are approved; (not applicable - does not change current MasterPlan on file with City) N/A GRADING PLAN, as applicable; N/A PRELIMINARY PLAT, as required (Note: Building permits will not be issued until evidence of recording a final plat is provided); N/A COPY OF RECORDED PLAT, as applicable; G. SITE PLAN SUBMITTAL REQUIREMENTS: (Section 4-202.A) O SITE PLAN with the following information (not to exceed 24" x 36"): _x_ All dimensions; _x_ North arrow; _x_ Engineering bar scale (minimum scale one inch equals 50 feet), and date prepared; _x_ Location map; _x_ Index sheet referencing individual sheets included in package; _x_ Footprint and size of all EXISTING buildings and structures; _x- Footprint and size of all PROPOSED buildings and structures; _x_ All required setbacks; -x- All existing and proposed points of access; -x- All required sight triangles; _x_ Identification of environmentally unique areas, such as watercourses, wetlands, tree masses, and specimen trees, including description and location of understory, ground cover vegetation and wildlife habitats, etc; -x- Location of all public and private easements; _x_ Location of all street rights-of-way within and adjacent to the site; I -K& 10-MCHVE JUL 11 2005 PLANNING CITY OF C Page 4 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater • 0R*1NAL _x_ Location of existing public and private utilities, including fire hydrants, storm and sanitary sewer lines, manholes and lift stations, gas and water lines; All parking spaces, driveways, loading areas and vehicular use areas; _x_ Depiction by shading or crosshatching of all required parking lot interior landscaped areas; _x_ Location of all solid waste containers, recycling or trash handling areas and outside mechanical equipment and all required screening (per Section 3-201(D)(i) and Index #701); _x_ Location of all landscape material; _x_ Location of all onsite and offsite storm-water management facilities; _x_ Location of all outdoor lighting fixtures; and _x_ Location of all existing and proposed sidewalks. O SITE DATA TABLE for existing, required, and proposed development, in written/tabular form: _x_ Land area in square feet and acres; _x_ Number of EXISTING dwelling units; _x_ Number of PROPOSED dwelling units; _x_ Gross floor area devoted to each use; _x_ Parking spaces: total number, presented in tabular form with the number of required spaces; _x_ Total paved area, including all paved parking spaces and driveways, expressed in square feet and percentage of the paved vehicular area; _x_ Size and species of all landscape material; _x_ Official records book and page numbers of all existing utility easement; _x_ Building and structure heights; _x_ Impermeable surface ratio (I.S.R.); and N/A Floor area ratio (F.A.R.) for all nonresidential uses. MID O REDUCED SITE PLAN to scale (8 Y] X 11) and color rendering if possible; ECE?VE O FOR DEVELOPMENTS OVER ONE ACRE, provide the following additional information on site plan: N/A One-foot contours or spot elevations on site; JUL 11 2005 N/A Offsite elevations if required to evaluate the proposed stormwater management for the parcel; N/A All open space areas; N/A Location of all earth or water retaining walls and earth berms; P?9l1NINC? DEPARTM N/A N/A Lot lines and building lines (dimensioned); Streets and drives (dimensioned); CITY OF CLEARWATI N/A Building and structural setbacks (dimensioned); N/A Structural overhangs; N/A Tree Inventory; prepared by a "certified arborist", of all trees 8" DBH or greater, reflecting size, canopy (drip lines) and condition of such trees. H. LANDSCAPING PLAN SUBMITTAL REQUIREMENTS: (Section 4-1102.A) 17 LANDSCAPE PLAN: _x_ All existing and proposed structures; _x_ Names of abutting streets; N/A Drainage and retention areas including swales, side slopes and bottom elevations; _x_ Delineation and dimensions of all required perimeter landscape buffers; _x_ Sight visibility triangles; _x_ Delineation and dimensions of all parking areas including landscaping islands and curbing; _x_ Proposed and required parking spaces; _x_ Existing trees on-site and immediately adjacent to the site, by species, size and locations, including driplines (as indicated on required tree survey); _x_ Plant schedule with a key (symbol or label) indicating the size, description, specifications and quantities of all existing and proposed landscape materials, including botanical and common names; _x_ Location, size, and quantities of all existing and proposed landscape materials, indicated by a key relating to the plant schedule; _x_ Typical planting details for trees, palms, shrubs and ground cover plants including instructions, soil mixes, backfilling, mulching and protective measures; _x_ Interior landscaping areas hatched and/or shaded and labeled and interior landscape coverage, expressing in both square feet and percentage covered; _x_ Conditions of a previous development approval (e.g. conditions imposed by the Community Development Board); (on file) _x_ Irrigation notes. O REDUCED LANDSCAPE PLAN to scale (8'/2 X 11) (color rendering if possible); 0 IRRIGATION PLAN (required for level two and three approval); (Fully irrigated - provided as design-build system, see notes on dwgs) O COMPREHENSIVE LANDSCAPE PROGRAM application, as applicable. Landscape associated with the Comprehensive Landscape Program shall exceed minimum Code requirements to offset the areas where minimum Code will not be met. Page 5 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater ORIGINAL BUILDING ELEVATION PLAN SUBMITTAL REQUIREMENTS: (Section 4-202.A.23) Required in the event the application includes a development where design standards are in issue (e.g. Tourist and Downtown Districts) or as part of a Comprehensive Infill Redevelopment Project or a Residential Infill Project. I] BUILDING ELEVATION DRAWINGS - all sides of all buildings including height dimensions, colors and materials; 17 REDUCED BUILDING ELEVATIONS - four sides of building with colors and materials to scale (8'% X 11) (black and white and color rendering, if possible) as required. J. SIGNAGE: (Division 19. SIGNS / Section 3-1806) O All EXISTING freestanding and attached signs; Provide photographs and dimensions (area, height, etc.), indicate whether they will be removed or to remain. N/A All PROPOSED freestanding and attached signs; Provide details including location, size, height, colors, materials and drawing; freestanding signs shall include the street address (numerals) N/A Comprehensive Sign Program application, as applicable (separate application and fee required). NIA Reduced signage proposal (8 '/2 X 11) (color), if submitting Comprehensive Sign Program application. K. TRAFFIC IMPACT STUDY: (Section 4-202.A.13 and 4-801.C) N/A Include if required by the Traffic Operations Manager or his/her designee or if the proposed development: • Will degrade the acceptable level of service for any roadway as adopted in the Comprehensive Plan. • Will generate 100 or more new vehicle directional trips per hour and/or 1000 or more new vehicle trips per day. • Will affect a nearby roadway segment and/or intersection with five (5) reportable accidents within the prior twelve (12) month period or that is on the City's annual list of most hazardous intersections. Trip generation shall be based on the most recent edition of the Institute of Transportation Engineer's (ITE) Trip General Manual. The Traffic Impact Study must be prepared in accordance with a "Scoping Meeting" held with the Traffic Operations Manager and the Planning Department's Development Review Manager or their designee (727-562-4750) Refer to Section 4-801 C of the Community Development Code for exceptions to this requirement. O Acknowledgement of traffic impact study requirements (Applicant must initial one of the following): Traffic Impact Study is included. The study must include a summary table of pre- and post-development levels of service for all roadway legs and each turning movement at all intersections identified in the Scoping Meeting. _aL- _ Traffic Impact Study is not required. (Project replaces the existing, dated modular building, not adding to the capactity of the facility CAUTION - IF APPLICATION REVIEW RESULTS IN THE REQUIREMENT FOR A TRAFFIC IMPACT STUDY AND NONE HAS BEEN SUBMITTED, APPLICATION MUST BE RESUBMITTED AND SIGNIFICANT DELAY MAY OCCUR. If you have questions regarding these requirements, contact the City Public Works Administration Engineering Department at (727) 562-4750. L. SIGNATURE: I, the undersigned, acknowledge that all representations made in this application are true and accurate to the best of my knowledge and authorize City representatives to visit and photograph the property described in this application. STATE OF FLORIDA, COUNTY OF PINELLAS Swor to and subscribed before me this 16 _?_ day of -4- A. D. 200 5 by _------ ___, o is personally kno has produced as identification owner or o s?xpJ6fne Carol Smith ommiss on 0356478 %OF Bt E*= September 27,2W8 w&d Troy RM • hwmim Na OW,TIS7" Page 6 of 7 - FlexAlhevIopmMmprehensive Infill Application 2005- City of Clearwater P"INIMIG DEPARTMENT t%FIV ^C C4 GAD1iA/ATIGD AFFIDAVIT TO AUTHORIZE AGENT: Barbara Green, Authorized Agent for Homeless Emergency Project, Inc 0 (Names of all property owners on deed - please PRINT full names) 1. That (I am/we are) the owner(s) and record title holder(s) of the following described property (address or general location): Existing structure located at 1200 Betty Lane, a part of the Homeless Emergency Project, Inc. 2. That this property constitutes the property for which a request for a: (describe request) Flexible Standard Development application being requested for the replacement of an existing, modular structure with a permanent structure. 3. That the undersigned (has/have) appointed and (does/do) appoint: Stephen B. Lafferty, AIA of Lafferty ARCHitecture Group LLC as (his/their) agent(s) to execute any petitions or other documents necessary to affect such petition; 4. That this affidavit has been executed to induce the City of Clearwater, Florida to consider and act on the above described property; 5. That site visits to the property are necessary by City representatives in order to process this application and the owner authorizes City representatives to visit and photograph the property described in this application; 6. That (]/we), the undersigned authority, hereby certify that the foregoing is true and correct. Property Owner Property Owner Property Owner STATE OF FLORIDA, COUNTY OF PINELLAS Before me the undersigned, an officer duly commissioned by the laws of the State of Florida, on this i ?-0d? p,?rsonally ao ea Depose and says that he/she fully understands the contents of the affidavit that he/she s' d My Commission Expires: WED JUL.11 2005 ORIGINAL who having been first Patricia Jean McAbee My Commission DD077392 or nP' Expires March 8, 2006 day of PUNNING DEPARTMENT Paget: Y MW ' A elopment Application- City of Clearwater _S 4! 5N D Homeless Emergency Project Inc. JUL 11 2005 Comprehensive Infill ReDevelopment Project Application Attachment "A" PLC NING DEPARTMENT CffVOF CLEARWATER Description of Request(s?. Comprehensive Infill Redevelopment Project review, Level 3, of a parcel that is currently non-conforming to provide aesthetic improvements and to replace an existing, outdated modular structure with a lower-scale, permanent structure. Existing parking conditions, drainage, setback conditions and density to remain unchanged. This facility will not increase the density of the development or provide additional services, but will provide better service to those clients and residents already being served by the existing facilities. Significant improvement in aesthetics and landscaping are proposed. This submittal is being accompanied by Comprehensive Landscape plan submittal. The current facility was constructed in approximately 1972, in compliance with zoning ordinances at the time. The Dining Hall and Kitchen, a modular structure was installed in 1974 and does not meet current wind load requirements. Adoption of ordinances subsequent to the property's construction has deemed the property non-compliant in the following: Parkin : Existing parking is partially on public rights of way, with no land available for on site parking. Current codes require 1 parking space per unit, or 18 total spaces required. Currently 2 parking spaces exist and the proposed project provides for 2 parking spaces and 2 loading spaces. Comprehensive Infill Redevelopment Projects do not have a specific parking requirement. A previous MasterPlan study conducted by Wade-Trim, Inc. earlier in 2005 encompassed the facilities shared by the Homeless Emergency Project, Inc. and Everybody's Tabernacle which provided an overall parking and drainage study. This Project will not provide any change to the studies already performed and approved. Landscaping: Due to the fact that there is little on site parking, no interior landscaping is provided at parking areas, but is provided surrounding it. The proposed plan significantly improves landscaping and utilizes a number of native, low maintenance and drought- tolerant species in the design. A comprehensive landscaping application is being made concurrently with this application. Setbacks: South (Front): The existing facility provides a front setback of 4.3 and 4.7 feet for widths of 24.7 feet at the each wing. Proposed setbacks would remain as existing at the wings, and the new structure is set back 25' from the Property Line, conforming to current requirements, which require a 25' front setback. North (Rear): The existing structure provides setbacks of 0.6 Feet to 1.7 Feet. This would remain unchanged. Current codes require 10' - 20' setbacks for Flexible Development, but setbacks are Not Applicable for Comprehensive Infill ReDevelopment Projects. West Side (Side): The existing structure provides a setback of 0.6 Feet. This would remain unchanged. Current codes require 0'-10' setbacks for Flexible Development, but setbacks are Not Applicable for Comprehensive Infill ReDevelopment Projects. East Side (Side): The existing structure provides a setback of 5.3 feet to the Property line with approximately 2 more feet to the sidewalk. This would remain unchanged. Current codes require 0'-10' setbacks for Flexible Development, but setbacks are Not Applicable for Comprehensive Infill ReDevelopment Projects 0 0 ORIGINAL Density: The existing facility, an Overnight Accommodation provides for 18 units on .43 acres, or approximately 42 units per acre. The use and density would remain unchanged. Pervious Areas: Currently the courtyard of the facility is 100% covered with buildings, asphalt and concrete, with the only significant pervious area on the east side and in front of the two wings to the south (front). The proposed design adds pervious area in the form of landscaped planting areas and a significant area of concrete pavers (semi-pervious). All drainage currently is surface drainage to the south and the proposed project will utilize gutters and surface drainage in the same direction and manner as existing. Drainage Narrative: The site has been in its current configuration since 1974 and all existing stormwater currently drains to the south, out of the courtyard and into city stormwater systems. The current site, less than 1/2 of one acre does not drain on to adjacent properties, retard, accelerate or divert water flow or prohibit proper maintenance, and there is not a current flooding problem immediately surrounding the site. The proposed project will not exacerbate existing stormwater conditions in the area, nor contribute to an existing flooding problem. The proposed design will utilize roof gutters and a more effective series of surface drainage slopes, which will provide a more directed and deliberate surface drainage systems that currently exists, furthering the safety and quality of the stormwater drainage. Where practical, roof gutters shall be drained to green areas to provide some level of treatment of stormwater before entering the city's stormwater collection system to the east. Appropriate splash blocks, rip-rap or similar treatment will be provided where necessary in order to avoid wash-outs. Due to the limited area of the site and the limited widths of the existing setbacks, the addition of any effective attenuation of stormwater is infeasible. A previous MasterPlan study conducted by Wade-Trim, Inc. earlier in 2005 encompassed the facilities shared by the Homeless Emergency Project, Inc. and Everybody's Tabernacle which provided an overall parking and drainage study. This Project will not provide any change to the studies already performed and approved. f D-) mECEVED JUL 11 2005 DIMMING DEPARTMENT OViYY OF CLEARWATER r Homeless Emergency Shelter Kitchen Addition Comprehensive Infill ReDevelopment Project Application SITE DATA Existing Land Area In Square Feet And Acres: Required Lot Area: ORIGINAL 18,754 Square Feet 0.43 Acres 20,000-40,000 Square Ft 0.46-0.92 Acres No Minimum Lot Size req'd for Comp. Infill Projects Number Of Existing Dwelling Units: Number Of Proposed Dwelling Units: Gross Floor Area Devoted To Each Use: Overnight Accommodation: Kitchen & Dining Area: 18 Units 18 Units Existing Proposed 8750 sf 8750 sf 2020 sf 4003 sf (NOTE: Kitchen & Dining are an accessory use, supporting the Overnight Accommodation use) Parking Spaces: Existing: 2 Proposed: 4* Required: 18** * 2 disabled parking spaces and 2 loading spaces to be provided. ** Parking concerns were addressed with overall master site plan review in April 2005. This facility is replacing an existing, ancillary facility to the Overnight Accommodation use and does not add to the use of the facility, but enhances the ability to provide services to the existing population of sheltered residents. No specific parking requirements required for Comprehensive Infill Projects. Land Use Dat Existing Proposed Required Total Paved Area (parking area): 908 sf 908 sf Total Paved Area (courtyard & walkway areas): 2,501 sf 3,301 sf Building Coverage: 10,770 sf 12,753 sf Total Impervious Area: 17,459 sf 16,962 sf Total Pervious Area: 1,295 sf 1,792 sf Impermeable Surface Ratio (I.S.R.)** 0.93 0.90 Building And Structure Heights (1 story): 14' 18' 25-50' Setbacks:** Front (Existing Building) 4.3' 4.3' 25'** Front (Proposed Building) 34.2' 25.2' 25'** Side - West (Existing Building) 0.6' 0.6' 0-101** Side - East (Existing Building) 5.3' 5.3' 0-101** Rear (Existing Building) 0.6' 0.6' 10-20'** Lot Width:** (Existing) 125' 125' 150-200'** **Note: No specific requirements are listed for Comprehensive Infill Projects. Floor Area Ratio (F.A.R.) For All Nonresidential Uses: N/A-Overnight Accommodation Size And Species Of All Landscape Material: See Landscape Plan Official Records Book And Page Numbers Of All Existing Utility Easements: See Survey There are no free-standing signs proposed with this project. One building-mounted sign exists - and shall remain. ?lrrf@?r?f Payment History For Case #: FLD2005-07063 7/6/2005 9:07AM Recorded .% pc Fee ID Description Fees Paid Date I'aid Check # Receipt 4' By Due 11iaorF° FL 200507011120567840 Flexible Commercial 1,205.00 0.00 1,205.00 7/1/2005 1243 1200500000000006163 R -D 0.00 Total Fees: $1,205.00 Paid: $1,205.00 TOTAL REMAINING DUE: $0.00 0 Page 1 of 1 CasePaymentHi story..rpt 0 1 Ip (?rlI V JUL0520M FLD2005-07063 1200 N BETTY LN Date Received: 07/01/2005 HOMELESS EMERGENCY PROJECT ZONING DISTRICT: C LAND USE: CG ATLAS PAGE: 269B PLANNER OF RECORD: MHR CLWCoverSheet 0 o :??????? Planning Department 100 South Myrtle Avenue Clearwater, Florida 33756 Telephone: 727-562-4567 Fax: 727-562-4865 ? SUBMIT ORIGINAL SIGNED AND NOTARIZEDAPPLICATION ? SUBMIT 14 COPIES OF THE ORIGINAL APPLICATION including 1) collated, 2) stapled and 3) folded sets of site plans r???iS- 0 70 CASE #: DATE RECE ?2`- I_-0? RECEIVED BY (staff initials): -------- ATLAS PAGE #: -------------- ZONING DISTRICT: --------------- LAND USE CLASSIFICATION: SURROUNDING USES OF ADJACENT PROPERTIES: NORTH: SOUTH: WEST: ? SUBMIT APPLICATION FEE$' NOTE: 15 TOTAL SETS OF INFORMATION REQUIRED (APPLICATIONS PLUS SITE PLAN SETS) ORIGINAL FLEXIBLE STANDARD DEVELOPMENT APPLICATION (Revised 11/18/03) -PLEASE TYPE OR PRINT --- A. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4202.A) APPLICANT NAME: Homeless Emergency Project MAILING ADDRESS: -1120 N. Betty Lane, Clearwater, Florida PHONE NUMBER: -(727) 442-9041 FAX NUMBER: ___(727) 443-4$3 __4+j?4_'_( S I CO --- PROPERTY OWNER(S): --Homeless- Emergency Project, Inc. (Must include ALL owners as listed on the deed - provide original signature(s) on page 6) AGENT NAME: -Lafferty ARCHitecture Group LLC / Stephen B. Lafferty, AIA MAILING ADDRESS: -11414 Seminole Boulevard, Suite 5, Largo, FL 33778 PHONE NUMBER: _727-399-1300_FAX NUMBER: -727-399-5777- -- CELL NUMBER: _____ 727-647-8697__-------- __ E-MAIL ADDRESS: ----- steve@LaffertyARCH.com--------- -_-_ B. PROPOSED DEVELOPMENT INFORMATION: (Code Section 4.202.A) STREET ADDRESS of subject site:-1200 Betty Lane, Clearwater, FL 33755- - JUL 0 1 2CC5 LEGAL DESCRIPTION: ___As noted on the Site Survey ------------------- --- - - --------- - (if not listed here, please note the location of this document in the submittal) PARCEL NUMBER: ---10 / 29 115 / 26550 / 003 10070 ---------- -------------------- F'a.QWlulI11 17- -?_' --=- , PARCEL SIZE: 0.43 Acres_ ----------------------------------- (acres, square feet) PROPOSED USE(S) AND SIZE(S): --Proposed use remains unchaged - Transient Accommodation of 18 rooms, 1 office and 1 dining facility. (number of dwelling units, hotel rooms or square footage of nonresidential use) -This project is to replace the existing dining hall, a Modular Building with a permanent structure. DESCRIPTION OF REQUEST(S): ___see next page and Attachment "A." Page 1 of 6 - Flexible Standard Development Application- City of Clearwater • VbRIGINAL Attach sheets and be specific when identifying the request (include all requested code deviations; e.g. reduction in regwired number of parking spaces, specific use etc.) See Attachment "A" for additional Information. Existing parking conditions, drainage, density, setback conditions to remain unchanged; Significant improvement in aesthetics and landscaping. DOES THIS APPLICATION INVOLVE THE TRANSFER OF DEVELOPMENT RIGHTS (TDR), A PREVIOUSLY APPROVED PLANNED UNIT DEVELOPMENT, OR A PREVIOUSLY APPROVED (CERTIFIED) SITE PLAN? YES NO _XX_ (if yes, attach a copy of the applicable documents) C. PROOF OF OWNERSHIP: (Code Section 4202.A.5) 0 SUBMIT A COPY OF THE TITLE INSURANCE POLICY, DEED TO THE PROPERTY OR SIGN AFFIDAVIT ATTESTING OWNERSHIP (see page 6) D. WRITTEN SUBMITTAL REQUIREMENTS: (Code Section 3-913.A) I] Provide complete responses to the six (6) GENERAL APPLICABILITY CRITERIA- Explain how each criteria is achieved, in detail: 1. The proposed development of the land will be in harmony with the scale, bulk, coverage, density and character of adjacent properties in which it is located. The proposed development will not change the scale, bulk, or coverage of the site or adjacent properties .--___________ It will actually reduce coverage, as paving is being removed and landscaping added. The proposed enhancements bring significant improvement in the character and experience of the community, as it replaces an elevated, modular structure with a more attractive, permanent and lower profile structure in the same location. The properties to the North and South are part of the same faith-based organization and are included in the organization's MasterPlan. 2. The proposed development will not hinder or discourage the appropriate development and use of adjacent land and buildings or significantly impair the value thereof. The proposed development will encourage the improvement of adjacent land and buildings by continuing to act as a good example of development in the area. Placing a permanent and more attractive structure on the site will improve the value of adjacent properties. The facility will replace the existing, dated structure, not add to the capacity of the facility, but better serve those already being served. 3. The proposed development will not adversely affect the health or safety or persons residing or working in the neighborhood of the proposed use. The proposed project will signicantly improve the health and safety of persons residing or working the neighbc will be designed to current building and life safety codes and will increase accessiblity to disabled persons. U U1 J U L 0 1 2005 4. The proposed development is designed to minimize traffic congestion. U The proposed development will not affect traffic patterns, as the use and traffic concerns will remain unchang rt R1 _ r FtFlvl?;' ?. J':: 1 ?CvOt4 The existing site is extremely constrained, and no feasible opportunities p parking I r r 8rtI } WAl ER are provided to enhance con ionsyond.wh exists 5. The proposed development is consistent with the community character of the immediate vicinity of the parcel proposed for development. See response to number 1 above. The new structure will be surrounded by the existing structure on 3 of 4 sides. The new structure provides for a lower profile, single-story structure built on grade rather than elevated as currently exists. The properties immediately adjacent to the site to the north and the south are part of the same faith-based organization and consistent in character. Property to the West is single-story, residential in nature. 6. The design of the proposed development minimizes adverse effects, including visual, acoustic and olfactory and hours of operation impacts, on adjacent properties. The proposed design enhances the visual appearance considerably, and enhanced landscaping and front elevation treatment will improve acoustic and olfactory concerns. A below-ground grease interceptor will also replace an above-ground fixture, adding to sanitary safety- Magnolia plants are being used in the courtyard to provide sweet, aromatic scents when blooming. Air conditioning units will be roof-mounted, screened from view by a parapet, which will also reduce ambient noise levels. Page 2 of 6 - Flexible Standard Development Application- City of Clearwater ? '90RIGINAL ? Provide complete responses to the applicable flexibility criteria for the specific land use as listed in each Zoning District to which the waiver is requested (use separate sheets as necessary) - Explain how each criteria is achieved, in detail: Non-conforming elements of parking and setbacks are to remain unchanged due to the extremely constrained site limitations. Landscaping, irrigation, aesthetics and public safety are improved significantly in this project of limited scope. E. STORMWATER PLAN SUBMITTAL REQUIREMENTS: (City of Clearwater Design Criteria Manual and 4-202.A.21) O STORMWATER PLAN including the following requirements: _n/a_ Existing topography extending 50 feet beyond all property lines; (not possible on sides due to proximity of adjacent structures) _n/a_ Proposed grading including finished floor elevations of all structures; (existing to remain, unchanged). _n/a_ All adjacent streets and municipal storm systems; (existing to remain, unchanged) _n/a__ Proposed stormwater detention/retention area including top of bank, toe of slope and outlet control structure; (existing to remain, unchanged) _n/a_ Stormwater calculations for attenuation and water quality; (not required, existing to remain, unchanged) _n/a_ Signature of Florida registered Professional Engineer on all plans and calculations (existing to remain, unchanged) n/a COPY OF PERMIT INQUIRY LETTER OR SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT (SWFWMD) PERMIT SUBMITTAL (SWFWMD approval is required prior to issuance of City Building Permit), if applicable n/a COPY OF STATE AND COUNTY STORMWATER SYSTEM TIE-IN PERMIT APPLICATIONS, N applicable F. SUPPLEMENTAL SUBMITTAL REQUIREMENTS: (Code Section 4-202.A) O SIGNED AND SEALED SURVEY (including legal description of property) -15 original copies submitted; 0 TREE SURVEY (including existing trees on site and within 25' of the adjacent site, by species, size (DBH 4" or greater), and location, including drip lines and indicating trees to be removed) - please design around the existing trees; MI LOCATION MAP OF THE PROPERTY; n/a PARKING DEMAND STUDY in conjunction with a request to make deviations to the parking standards lie. Reduce number of spaces). Prior to the submittal of this application, the methodology of such study shall be approved by the Community Development Coordinator and shall be in accordance with accepted traffic engineering principles. The findings of the study will be used in determining whether or not deviations to the parking standards are approved; Not required for Level I review per s n/a GRADING PLAN, as applicable; (existing to remain, unchanged) n/a PRELIMINARY PLAT, as required (Note: Building permits will not be issued until evidence of recording a final plat is provided); rVa COPY OF RECORDED PLAT, as applicable; G. SITE PLAN SUBMITTAL REQUIREMENTS: (Section 4.202.A)'"" '_' x? SITE PLAN with the following information (not to exceed 24" x 36"): All dimensions;i ' q E _x_ North arrow; l +: "i r ^. # _x_ Engineering bar scale (minimum scale one inch equals 50 feet), and date prepared; -?.? _x_ Location map; _x_ Index sheet referencing individual sheets included in package; P?d)1jINCM _ retry _x__ Footprint and size of all EXISTING buildings and structures; _x_ Footprint and size of all PROPOSED buildings and structures; Page 3 of 6 - Flexible Development Application- City of Clearwater _x__ All required setbacks; ORIGINAL _x__ All existing and proposed points of access; _x_ All required sight triangles; n/a Identification of environmentally unique areas, such as watercourses, wetlands, tree masses, and specimen trees, including description and location of understory, ground cover vegetation and wildlife habitats, etc; _x__ Location of all public and private easements; _x__ Location of all street rights-of-way within and adjacent to the site; _x__ Location of existing public and private utilities, including fire hydrants, storm and sanitary sewer lines, manholes and lift stations, gas and water lines; _x__ All parking spaces, driveways, loading areas and vehicular use areas; _x__ Depiction by shading or crosshatching of all required parking lot interior landscaped areas; _xLocation of all solid waste containers, recycling or trash handling areas and outside mechanical equipment and all required screening {per Section 3-201(D)(i) and Index #701); _x__ Location of all landscape material; _x__ Location of all onsite and offsite storm-water management facilities; _x__ Location of all outdoor lighting fixtures; and _x__ Location of all existing and proposed sidewalks. 21 SITE DATA TABLE for existing, required, and proposed development, in written/tabular form: _x__ Land area in square feet and acres; Number of EXISTING dwelling units; Number of PROPOSED dwelling units; _x__ Gross floor area devoted to each use; _x__ Parking spaces: total number, presented in tabular form with the number of required spaces; _x__ Total paved area, including all paved parking spaces and driveways, expressed in square feet and percentage of the paved vehicular area; Size and species of all landscape material; Official records book and page numbers of all existing utility easement; _x__ Building and structure heights; _x__ Impermeable surface ratio (I.S.R.); and _x__ Floor area ratio (F.A.R.) for all nonresidential uses. I] REDUCED SITE PLAN to scale (8'/z X 11) and color rendering if possible; n/a FOR DEVELOPMENTS OVER ONE ACRE, provide the following additional information on site plan: n/a_ One-foot contours or spot elevations on site; n/a_ Offsite elevations if required to evaluate the proposed stormwater management for the parcel; n/a All open space areas; n/a_ Location of all earth or water retaining walls and earth berms; n/a_ Lot lines and building lines (dimensioned); n/a_ Streets and drives (dimensioned); n/a_ Building and structural setbacks (dimensioned); n/a_ Structural overhangs; n/a_ Tree Inventory; prepared by a "certified arborist", of all trees 8" DBH or greater, reflecting size, canopy (drip lines) and condition of such trees. H. LANDSCAPING PLAN SUBMITTAL REQUIREMENTS: (Section 41102.A) M1. 21 LANDSCAPE PLAN: _x__ All existing and proposed structures; F ?? o ??? Names of abutting streets; _x_ Drainage and retention areas including swales, side slopes and bottom elevations; _xDelineation and dimensions of all required perimeter landscape buffers; Sight visibility triangles; Pt.A?VlVlrlG :. i , ' ?? CITY Q,= CL, :t,i-4 AT Delineation and dimensions of all parking areas including landscaping islands and curbing; _x__ Proposed and required parking spaces; Existing trees on-site and immediately adjacent to the site, by species, size and locations, including dripline (as indicated on required tree survey); Plant schedule with a key (symbol or label) indicating the size, description, specifications and quantities of all existing and proposed landscape materials, including botanical and common names; Location, size, and quantities of all existing and proposed landscape materials, indicated by a key relating to the plant schedule; Typical planting details for trees, palms, shrubs and ground cover plants including instructions, soil mixes, backfilling, mulching and protective measures; _xInterior landscaping areas hatched and/or shaded and labeled and interior landscape coverage, expressing in both square feet and percentage covered; Page 4 of 6 - Flexible Standard Development Application- City of Clearwater ORIGINAL -n/a_ Conditions of a previous development approval (e.g. conditions imposed by the Community Development Board); _x__ Irrigation notes. I] REDUCED LANDSCAPE PLAN to scale (81/2X 11) (11"x17") SUBMITTED _n/a_ IRRIGATION PLAN (required for level two and three approval); _x__ COMPREHENSIVE LANDSCAPE PROGRAM application, as applicable. 1. BUILDING ELEVATION SUBMITTAL REQUIREMENTS: (Section 4202.A.23) Required in the event the application includes a development where design standards are in issue (e.g. Tourist and Downtown Districts) or as part of a Comprehensive Infill Redevelopment Project or a Residential Infill Project. I] BUILDING ELEVATION DRAWINGS- all sides of all buildings including height dimensions, colors and materials; O REDUCED BUILDING ELEVATIONS - four sides of building with colors and materials to scale (8 % X 11) (black and white and color rendering, if possible) as required. J. SIGNAGE: (Division 19. SIGNS / Section 3-1806) Z All EXISTING freestanding and attached signs; Provide photographs and dimensions (area, height, etc.), indicate whether they will be removed or to remain. _n/a- All PROPOSED freestanding and attached signs; Provide details including location, size, height, colors, materials and drawing; freestanding signs shall include the street address (numerals) -n/a_ Comprehensive Sign Program application, as applicable (separate application and fee required). _n/a_ Reduced signage proposal (8 '/Y X 11) (color), if submitting Comprehensive Sign Program application. K. TRAFFIC IMPACT STUDY: (Section 4.202.A.13 and 4801.C) JUL 0 1 2005 FLAiWNG 8 Gi - , JSti'06 CIW OF CI_ hip r ° ?I LR -n/a_ Include as required if proposed development will degrade the acceptable level of service for any roadway as adopted in the Comprehensive Plan. Trip generation shall be based on the most recent edition of the Institute of Transportation Engineer's Trip General Manual. Refer to Section 4-801 C of the Community Development Code for exceptions to this requirement. L. SIGNATURE: I, the undersigned, acknowledge that all representations made in this q"pation are true and accurate to the best of my knowledge and authorize resentatives to visit and photograph the property desc --his apple ' . STATE OF FLORIDA, COUNTY OF PINELLAS Sworn to and subscribed before me this ______ day of (ALA A.D. 20 A 5- to me and/or by who is personally known has prod.w ed ---------------- ^ -------- as Signature of property owner or representative My commission expires: Pab ida Joan McAbee My Commission DD077302 Doe Zoi E.Vires March 8, 2008 Page 5 of 6 - Flexible Standard Development Application- City of Clearwater AFFIDAVIT TO AUTHORIZE AGENT: Barbara Green, Authorized Agent for Homeless Emergency Project, Inc ORIGINAL (Names of all property owners on deed - please PRINT full names) 1. That (I am/we are) the owner(s) and record title holder(s) of the following described property (address or general location): Existing structure located at 1200 Betty Lane, a part of the Homeless Emergency Project, Inc. 2. That this property constitutes the property for which a request for a: (describe request) Flexible Standard Development application being requested for the replacement of an existing, modular structure with a permanent structure. 3. That the undersigned (has/have) appointed and (does/do) appoint: Stephen B. Lafferty, AIA of Lafferty ARCHitecture Group LLC as (his/their) agent(s) to execute any petitions or other documents necessary to affect such petition; 4. That this affidavit has been executed to induce the City of Clearwater, Florida to consider and act on the above described property; 5. That site visits to the property are necessary by City representatives in order to process this application and th"'o i' rli CitX i representatives to visit and photograph the property described in this application; U L L' 6. That (11we), the undersigned authority, hereby certify that the foregoing is true and correct. IL)l 0 12005 Prope er Fi-ttl 1?11(vG 6V 01 Property Owner Property Owner Property Owner STATE OF FLORIDA, COUNTY OF PINELLAS Before me the undersigned, an officer duly commissioned by the laws of the State of Florida, on day of this 0 5 personally aooeared who having been first duly orn Depose and says that he/she fully understands the contents of the affidavit that he/she s'_ d. z7zz-7 My Commission Expires: elk- PWcla Jean McAbee My Commission DD077392 OF Expires March 8, 2006 Page 6 of 6 - Flexible Standard Development Application- City of Clearwater 0 Homeless Emergency Project Inc. Flexible Standard Development Application Attachment "A" 0 ORIGINAL Description of Request(s): Flexible Standard Development review, Level 2, of a parcel that is currently non-conforming to provide aesthetic improvements and to replace an existing, outdated modular structure with a lower-scale, permanent structure. Existing parking conditions, drainage, setback conditions and density to remain unchanged. This facility will not increase the density of the development or provide additional services, but will provide better service to those clients and residents already being served by the existing facilities. Significant improvement in aesthetics and landscaping are proposed. This submittal is being accompanied by Comprehensive Landscape plan submittal. The current facility was constructed in approximately 1972, in compliance with zoning ordinances at the time. Adoption of ordinances subsequent to the property's construction has deemed the property non-compliant in the following: Parkin : Existing parking is partially on public rights of way, with no land available for on site parking. A previous MasterPlan study conducted by Wade-Trim, Inc. encompassed the facilities shared by the Homeless Emergency Project, Inc. and Everybody's Tabernacle which provided an overall parking and drainage study. Landscaping: Due to the fact that there is little on site parking, no interior landscaping is provided at parking areas, but is provided surrounding it. The proposed plan significantly improves landscaping and utilizes a number of native, low maintenance and drought- tolerant species in the design. A comprehensive landscaping application is being made concurrently with this application. Setbacks: South (Front): The existing facility provides a front setback of 4.3 and 4.7 feet for widths of 24.7 feet at the each wing. Proposed setbacks would remain as existing at the wings, and the new structure is set back 25' from the Property Line, conforming to current requirements. North (Rear): The existing structure provides setbacks of 0.6 Feet to 1.7 Feet. This would remain unchanged. West Side (Side): The existing structure provides a setback of 0.6 Feet. This would remain unchanged. East Side (Side): The existing structure provides a setback of 5.3 feet to the Property line with approximately 2 more feet to the sidewalk. This would remain unchanged. Density: The existing facility, an Overnight Accommodation provides for 18 units on .43 acres, or approximately 42 units per acre. The use would remain unchanged. Pervious Areas: Currently the courtyard of the facility is 100% covered with buildings, asphalt and concrete. The proposed design adds pervious area in the form of landscaped planting areas and a significant area of concrete pavers (semi-pervious). All drainage currently is surface drainage to the south and the proposed project will utilize gutters and surface drainage in the same direction and manner as existing i F. JUL 0 1 2005 (J PMENT u i v+J f .t"_i'AATER • Homeless Emergency Shelter Kitchen Addition Flexible Standard Development Application SITE DATA Land Area In Square Feet And Acres: Number Of Existing Dwelling Units: Number Of Proposed Dwelling Units: ORIGINAL 18,754 Square Feet .43 Acres 18 Units 18 Units Gross Floor Area Devoted To Each Use: Overnight Accommodation Kitchen & Dining Area: Parking Spaces: Existing Proposed 8750 sf 8750 sf 2020 sf 4003 sf (NOTE: Kitchen & Dining are an accessory use, supporting the Overnight Accommodation use) Existing: 2 Proposed: 4 (total) Land Use Data: Total Paved Area (parking area): Total Paved Area (courtyard & walkway areas) Building Coverage: Total Impervious Area: Total Pervious Area: Impermeable Surface Ratio (I.S.R.) Building And Structure Heights: 908 sf 908 sf 2,501 sf 3,301 sf 10,770 sf 12,753 sf 17,459 sf 16,962 sf 1,295 sf 1,792 sf 0.074 0.105 14' 18' Floor Area Ratio (F.A.R.) For All Nonresidential Uses: N/A-Overnight Accommodation Size And Species Of All Landscape Material: See Landscape Plan Official Records Book And Page Numbers Of All Existing Utility Easements: See Survey 0 Planning and Development Services 100 South Myrtle Avenue Clearwater, Florida 33756 Telephone: 727-562-4567 Fax: 727-562-4576 ? SUBMIT ORIGINAL SIGNED AND NOTARIZED APPLICATION ? SUBMIT 1 COPY OF THE ORIGINAL APPLICATION including folded site plan ORIGINAL CASE #: _ _ DATE RECEIVED _ __ RECEIVED BY (staff initials):. ATLAS PAGE #: ZONING DISTRICT: LAND USE CLASSIFICATION: ZONING & LAND USE CLASSIFICATION OF ADJACENT PROPERTIES: NORTH: SOUTH: / ------- ---- WEST: ------------ / -------- EAST: / COMPREHENSIVE LANDSCAPE PROGRAM REQUIREMENTS (Revised 9/19/2001) D. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4-1001) APPLICANT NAME: _-Homeless Emergency Project Inc._____-___----------- ------------------- -____---- MAILING ADDRESS: __1120 N. Betty Lane, Clearwater, Florida 33755_- PHONE NUMBER: _------ (727) 442-9041FAX NUMBER: ----(727) 443-4875___ ' --_--- PROPERTY OWNER(S): _-Homeless Emergency Project, Inc._- -___-_____ (Must include ALL owners) -?? , -_f II G? i_ XM'Ki AGENT NAME: (Contact Person) ___-_Lafferty ARCHitecture Group LLC (Stephen B. Lafferty, AIA )------ __________- =_T- ??---? MAILING ADDRESS: ___--_----__11414 Seminole Blvd, Suite 5, Largo, FL 33778 - PHONE NUMBER: 727-399-1300_----- FAX NUMBER: - 727-399-5777 The landscaping requirements of Article 3 Division 12 may be waived or modified as a part of a Level One or Level Two Approval, as the case may be, if the application for development approval includes a Comprehensive Landscape Program, which satisfies the following criteria. The use of landscape plans; sections/elevations, renderings and perspectives may be necessary as supplementary information in addition to the information provided on this worksheet: Architectural Theme. a. The landscaping in a Comprehensive Landscape Program shall be designed as a part of the architectural theme of the principal buildings proposed or developed on the parcel proposed for the development. The architectural theme for this proposal is a low-scale, low maintenance solution to match the adjacent surrounding properties. The land scag .Loosed reflects a warm southern, residential feel with colorful foundation planting along the south and east sides, where landscaping is possible. In the courtyard, a shade-producing canopy is created using Ions-branch Queen Palms and a center accent tree (Southern Magnolia) will fill out the canopy and provide attractive and aromatic flowers when blooming. These plants as well as native landscape materials shall offer a great deal of color and fragrance to the area. Page 1 of 3 1 ?1 • OR ORIGINAL b. The design, character, location and/or materials of the landscape treatment proposed in the Comprehensive Landscape Program shall be demonstrably more attractive than landscaping otherwise permitted on the parcel proposed for development under the minimum landscape standards. 2. Lighting. Any lighting proposed as a part of a Comprehensive Landscape Program is automatically controlled so that the lighting is turned off when the business is closed. Community Character. The landscape treatment proposed in the Comprehensive Landscape Program will enhance the community character of the City of Clearwater. ?? ?U' 0 ? 2005 Page 2 of 3 ORPGINAL 4. Property Values. The landscape treatment proposed in the Comprehensive Landscape Program will have a beneficial impact on the value of the property in the immediate vicinity of the parcel proposed for development. 5. Special Area or Scenic Corridor Plan. The landscape treatment proposed in the Comprehensive Landscape Program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the parcel proposed for development is located. Not Applicable s Please return checklist for review and verification. Date: (Signature of applicant) S: application forms/development review/comprehensive landscape program application.doc Page 3 of 3 ORIGINAL EXISTING WEST VIEW (UNCHANGED) SCALE: NTS. • COLOR. all YELLOWJU166I- COLOR- SILENT YELLOW SUA661 TILE ACCENT TO MATCH T ATCH EXISTING' SILENT YEI.IOW - RETURN AROVID ?- COLOR- WHITE COLOR- SILENT YELLOW ?SW661 .//I/-118 NG EXIST 1 S'-0' WAL !ff BUILDN COLOR- GREY SHINGLEa TO MATCH EXISTING DOLOR- SILENT YELLOW 911661 THATCH EXISTING- RETWR! AIrYJ121D CEMENTITIOlS COATING VU DECORATIVE SCORW ACID dPPLIED PIL49TER9 COLOR. T-OT1AL T'LE ACGQlTS COLOR- FOR'IAL GARDEN SW455 GARDEN 91458 SPLIT FACE C11J COLOR- HORZCNTAL BANDING EClal WI WJIre dGISGAre A" LIED CEME14TITIOUS COATNG ACCENT T BAND ON PROPOSED SOUTH ELEVATION EXUTNBAND ON ' SCALE: I/a'•I'-0' i F ?" (`?F r .i t?t1J'C,jY ? ? 1 ? /1 ? S•?..+?.--...Y_ . ?`?. ?? CIS .alga C { j1 Lafferty Archilecturo Orou L.L.C. P )21-h9-f J00 F 12)]99S1)T InleQlaflerlynPCN.c•m f f •f a s•mi„W. ewq sf. s L•rge, R JJTT9 FL UG AANi009a1 z 0 zQw? wgZ0 ?z H? wr?m c a ?w O? v .T Lm Stephen D. Lafferty, AfA FL L1c ARI-5, ID3610 PROPOSED SITE PLAN AND ELEVATIONS vmj.d / L05-29 ` Th05 ?A-1(11 e1+DWN PROPOSED ARCHITECTURAL SITE PLAN SCALE: I'•7®'-0' NOTE: SITE DATA TABLE SLI 111TED AND ATTACHED TO APPLICATION. EXISTING EAST ELEVATION (UNCHANGED) SCALE: N.TS. ORIGINAL i EXISTING OAK TREES EXISTNG OAK TREES ON ON ADJACENT ADJACENT PROPERTY T\ EXISTING ppOPER{Y BUILDW. TO r nwav] uw o REMAIN rr_r- 7 T 7- - ---- 77-, ; - Boo h /j / / ' ' / /d FLOlLER1NG ANNUALS TO ANTE- Nadia I RESIDENTS AT BASE OF PALM TREES, TYP. AEnATE Exurwr, DaL I '? i /' eAOmu EXIS STING -a- 601E / / / / G1P I I / I 20?LAYIMB r - ? AT NO NAIL N TIDE alOOO - / atFT= Tee C ]• k 4. 01 rP.TJ I I l DPACE PXEE AT RO 11I r x s• DrAIeE rP.u ?i / THFEE FEET LQIG I / ?/; 4• na DAnCER IeM _ FNINI tAADE-L I / { / RADAtl FEADw FLU• 21Y irdNC I I II n+ •'? - WAaNEO-M ANO fArV40 I / ?,. I tOlL F1 11 I -I I E Tar G d1eGRADE Al I -III-IIMIII 2EE STAKING AND PLANTING DETAIL I I ?? eeNrwwrore ewau rmNOyt erAlcwn aNO aureG I / /I =}0 i { INRIM013A3Ci v x!#23 2' +rI I? ? I f ? `?I II rRa -?no.ramaaer ."°.awe .pro on•• /-,_. f /ELE, ?/ 6>P 1 J'?7 _ ba a.?. 5151 F' I :; 5002 0 /' ?. r mAn,nyA_ ..r. NAO,x?' .,A.aa o..xxe.+o xrao ( 2 ??II / . . Male A.a.. /, ::tee ..oo,. .oa.d?«.u a...o o.ox k,.uo.oV..+...wm.... r•. ??"""•?,?a..xe _. /{' /?ti )? 'T9 ?f4 ?..a.xa, r.,.a.aa .LL.a.a,A..ta„a.LL,.a--_ ??ra: r •• ? `?•' L ?I ? { ? + ?i1 ? ! ? ? J ai..roiaL rlaaro om,ru urumooooarow r..?:'• -•i r•? ..;.: ... ''. MMOeL, aaMr Aaapato. ram51CMMOM,Y]s y....?_... lea[:}-. ' c^reacrv e. ? .?rtaenr.,a,ue,ea asaa ena.s \? I PLANT MATERIAL LIST Abbrev Common Name Sc1en118c Name Soacills.0ons 3 MGL DAan Magnolia'Litlle Gem' Magdnlia g2nafRora little gam 16, oNalner gown, a' IT, 4' spa.. all 8 OP Oueen Palm Syagru5 romanzo/liana 117 hl. x 5 spr., W gal min 10 Lt Grape Myrtle Leg-tmemia induce 10' M x 64r spr. 3 CL Areca Palm Chryselltlocarpus lurescans e' hl. x 3'-0• apr., mu1 li4mnked VO Walters Viburnum Vibumum obovatum 24" ht x 12" spr, 3 gal min spaced 30" O.C. SAV Schegelera Variegated SMetlelena arbodcolla - - 24' ht x 12'spr, 3 gal min spaced 30"0,C. Notes 1 All plants shall be Honda No 1 Grade. T 5AV .? NEW BUILIDING TO 3 CL SIDEWALK 8 SAV E X I S T I N G T SAv A S P H A L T 0 R I V E W A Y / I ? I ' , ?7- l ILI / ? I Ib°II ??tr / I 1 l Oh I , /I I I I I ' I n ? ? I ?_a5R , Z a O a LU W 60 v0 L f rEX15TINC TO RAV EXIST. RETAINING U TO REMAIN EXISTNG ALM TREE TO AIN LaSALLE ST. (MADISON ST. 60' R/W PER PLAT) PROPOSED LANDSCAPE PLAN ?N.ev M-- 9CALE? I°•I®'-0' I. Ewartio rlffes TO RE rtae® Ar0 eNam eo NO o-lAU eNana:D Exr@0 eElw e' -n• AeR.E enaoE r. FENnuIE ANO eaaAra? ALL rau AN. E.. PLANra1a Area aln2PEAT MODD AND AAa?2NedlE Ma.G. IQ-a10r£ Arr2'FrnEIpI OEeYeD. PLANTING MATERIAL LIST Lafferty Arehito,ture Oroap L.L.C. F 727.2519. F 727-2519-11M Into®La11enYAACHARtff. cam 11414 Seminole Fill $to S Largo, NL 227711 n ue nazsao51ol z 2 U zqw? a?z0 wzaw W W W vniHW? CID ??t O,Hj?V W N Stephen D. Lafferty, AIA FL Lt. AN1226S, ID3614 r a.r. ar LANDSCAPE PLAN Praiadl A- L05-29 rA? ~I710 1 M SttDYN I?-I I ix -i 514RU15 PLANTING DETAIL 0 ORIGINAL LOT 10 BLOCK C I io'.J1a„e1 LOT 4 BLOCK C a LOT 5 BLOCK C LOT 6 BLOCK C N 8919'IJ" E (N) 1110)' (YJ LOT 9 eu BLOCK C sx?^ LOT D BLOCK C 3 _ PROPOSED BUILDING , ae $ LOT 7 BLOCK C xi (vI 16 ??? 6? M?KiM ?Mfi fd lYlr O1ra? IrYa i ?.sro ? Ios:°:..sncl I I I • •s ?i •e a ?iV•a SECTION 10, TOWNSHIP 29 SOUTH. RANGE 15 EAST PINELLAS COUNTY, FLORIDA sueaL ltwo TIa1C'n11'S 110 R? M pR?.f? Mr oM ®wlatY.?[mps?a eww. _ f ??r? -ui eaMM? ? ? w aw?ct?m SAM ern?aa??6W OwMt w?W?r?tt?n?Mlm 1/1a/!m .1 lV un. air. i? i a A ?wrr? matm e[ rmia rsnw¢ oMa,??EEanam xuue owrwr ua. e[ MRl Sae.iY e) ?m ? ?milr?il vleQ?mm awaRa?am[r. wnlle?i rim Lafferty Architecture Droup L.L.C. p ]2]-a9a•faW Info®LeflerlyARCN.com L.r"F ]Y]J98, M !]]] 11+11 Mrd. !ta! Largo, FL aana FL uc AA26009et z 00 V Q w O w W ? ?^ wx?H ~ a o t w x Stephen 6. Lafferty, AIA FL Llc AM 2265, ID3614 SURVEY I'roJacl / 1-05-29 rC-101 A6 SHOAN IL 1. 1 A LONG RANGE PLANNING DEVELOPMENT REVIEW 0 f CLTY OF CLEARWAT,ER PLANNING DEPARTMENT POST OFFICE Box 4748, CLEARWATER, FLORIDA 33758-4748 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAX (727) 562-4576 September 22, 2005 Mr. Stephen B. Lafferty, AIA Lafferty Architecture Group LLC 11414 Seminole Boulevard, Suite 5 Largo, FL 33778 RE: Development Order - Case FLD2005-07063 - 1200 North Betty Lane Dear Mr. Lafferty: This letter constitutes a Development Order pursuant to Section 4-206D.6 of the Community Development Code. On September 20, 2005, the Community Development Board reviewed your Flexible Development application to permit the redevelopment and expansion of an existing residential shelter (including the expansion of the kitchen and dining area), in the Commercial District, to maintain the existing front, side and rear setbacks with the exception of a front (south) setback of 4 feet (to dumpster enclosure), and to permit off site parking, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G. for the site at 1200 North Betty Lane. The CDB APPROVED the application based upon the following findings of fact, conclusions of law, and conditions of approval: Findings of Fact: 1. Subject property is 18,730 square feet (0.43 acres), approximately 125 feet wide; 2. The site is within the Commercial (C) District and the Commercial General (CG) future land use plan classification; 3. Applicant seeks to redevelop and expand an existing residential shelter, including the expansion of the kitchen and dining area, maintaining the existing front, side, and rear setbacks with the exception of the front (south) setback of four feet (to dumpster enclosure) and to permit off-site parking as a Comprehensive Infill Project under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G.; Other improvements include the provision of a loading space and handicap parking space at the front of the building, landscaping, new roofing, exterior painting, and bicycle parking; and BRIAN J. AUNGST, MAYOR-COMMISSIONER HOYT HAMILTON, VICE MAYOR-COMMISSIONER WHITNEY GRAY, COMMISSIONER FRANK HIBBARD, COMMISSIONER ® BIIJ.JONSON, COMMISSIONER "EQUAL EMPLOYMENT AND AFFIRMATIVE ACTION EMPLOYER" 0 September 22, 2005 Stephen B. Lafferty, AIA - Page Two 4. No other changes are proposed for. the site or building. • Conclusions of Law: 1. Staff finds the proposal compliant with the General Purposes of the Code per Sections 1- 103.A, B.2, E.9 and E.12; 2. Staff finds the proposal compliant with the Flexible Development criteria per Section 2- 704.C 3. Staff further finds the proposal compliant with the Flexible Development criteria as a Comprehensive Infill Redevelopment Project per Section 2-704.C and General Applicability Standards per Section 3-913; and 4. Staff recommends Board approval of FLD2005-05038 based on the recommended findings of fact and conditions as stated. Conditions of Approval: ' 1. That all signage meet Code, including the removal/redesign of any existing nonconforming signs, through building permits prior to the issuance of a certificate of occupancy for the applicable site; 2. All Fire Department comments are to be met prior to any building permit issuance; 3. That a Right-of-Way utilization permit be obtained prior to building permit issuance; 4. That prior to building permit issuance, the site plan be revised, to the satisfaction of City staff, to show 23 feet in length parallel parking spaces; and 5. That the applicant make payment in lieu for stormwater attenuation prior to building permit issuance. Pursuant to Section 4-407, an application for a building permit shall be made within one year of Flexible Development approval (by September 20, 2006). All required certificates of occupancy shall be obtained within two years of the date of issuance of the building permit. Time frames do not change with successive owners. The Community Development Coordinator may grant an extension of time for a period not to exceed one year and only within the original period of validity. The Community Development Board may approve one additional extension of time after the Community Development Coordinator's extension to initiate a building permit application. The issuance of this Development Order does not relieve you of the necessity to obtain any building permits or pay any impact fees that may be required. In order to facilitate the issuance of any permit or license affected by this approval, please bring a copy of this letter with you when applying for any permits or licenses that require this prior development approval. Additionally, an appeal of a Level Two approval (Flexible Development) may be initiated pursuant to Section 4-502.B by the applicant or by any person granted party status within 14 days of the date of the Community Development Board meeting. The filing of an application/notice September 22, 2005 Stephen B. Lafferty, AIA - Page Three of appeal shall stay the effect of the decision pending the final determination of the case. The appeal period for your case expires on October 4, 2005. If you have any questions, please do not hesitate to call Michael H. Reynolds, AICP, Planner IIl, at 727-562-4836. You can access zoning information for parcels within the City through our website: www.clearwater-fl.com. Sincerely, Michael Delk, tCP Planning Director S:Wlanning DepartmenhC D BIFLEX (FLD)Unactive or Finished Applications Oetty N 1200 -Homeless Emergency Project (C) - 9-20-05 - MHR - Approved0evelopment Order.doc FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT 100 S. MYRTLE AVE., 2nd Floor CLEARWATER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 FAX: c3f9 ,Jr? 7 7 Phone: FROM: 17`eVAtc tOKI Phone: J'-G 2 DATE: ;Z6 _ 6J' SUBJECT: .?Lg Zo ol-- D 7 b G/ 3 MESSAGE: ??? ?,4/., ?ly,?- ' elgf ? NUMBER OF PAGES(INCLUDING THIS PAGE) • • LONG RANGE PLANNING DEVELOPMENT REVIEW CITY. OF C LEARWATE R. PLANNING DEPARTMENT POST OFFICE BOX 4748, CLEARWATER, FLORIDA 33758-4748 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAx (727) 562-4576 September 22, 2005 Mr. Stephen B. Lafferty, AIA Lafferty Architecture Group LLC 11414 Seminole Boulevard, Suite 5 Largo, FL 33778 RE: Development Order - Case FLD2005-07063 - 1200 North Betty Lane Dear Mr. Lafferty: This letter constitutes a Development Order pursuant to Section 4-206D.6 of the Community Development Code. On September 20, 2005, the Community Development Board reviewed your Flexible Development application to permit the redevelopment and expansion of an existing residential shelter (including the expansion of the kitchen and dining area), in the Commercial District, to maintain the existing front, side and rear setbacks with the exception of a front (south) setback of 4 feet (to dumpster enclosure), and to permit off site parking, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G. for the site at 1200 North Betty Lane. The CDB APPROVED the application based upon the following findings of fact, conclusions of law, and conditions of approval: Findings of Fact: 1. Subject property is 18,730 square feet (0.43 acres), approximately 125 feet wide; 2. The site is within the Commercial (C) District and the Commercial General (CG) future land use plan classification; 3. Applicant seeks to redevelop and expand an existing residential shelter, including the expansion of the kitchen and dining area, maintaining the existing front, side, and rear setbacks with the exception of the front (south) setback of four feet (to dumpster enclosure) and to permit off-site parking as a Comprehensive Infill Project under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G.; Other improvements include the provision of a loading space and handicap parking space at the front of the building, landscaping, new roofing, exterior painting, and bicycle parking; and BRIAN J. AUNGST, MAYOR-COMMISSIONER HOYT HAMILTON, VICE MAYOR-COMMISSIONER WHITNEY GRAY, COMMISSIONER FRANK HIBBARD, COMMISSIONER ® BII.I.JONSON, COMMISSIONER "EQUAL, EMPI.OYMF,NT AND AFFIRMATIVE ACTION EMPLOYER" September 22, 2005 Stephen B. Lafferty, AIA - Page Two 4. No other changes are proposed for. the site or building. Conclusions of Law: 1. Staff finds the proposal compliant with the General Purposes of the Code per Sections 1- 103.A, B.2, E.9 and E.12; 2. Staff finds the proposal compliant with the Flexible Development criteria per Section 2- 704.C 3. Staff further finds the proposal compliant with the Flexible Development criteria as a Comprehensive Infill Redevelopment Project per Section 2-704.C and General Applicability Standards per Section 3-913; and 4. Staff recommends Board approval of FLD2005-05038 based on the recommended findings of fact and conditions as stated. Conditions of Approval: ' 1. That all signage meet Code, including the removal/redesign of any existing nonconforming signs, through building permits prior to the issuance of a certificate of occupancy for the applicable site; 2. All Fire Department comments are to be met prior to any building permit issuance; 3. That a Right-of-Way utilization permit be obtained prior to building permit issuance; 4. That prior to building permit issuance, the site plan be revised, to the satisfaction of City staff, to show 23 feet in length parallel parking spaces; and 5. That the applicant make payment in lieu for stormwater attenuation prior to building permit issuance. Pursuant to Section 4-407, an application for a building permit shall be made within one year of Flexible Development approval (by September 20, 2006). All required certificates of occupancy shall be obtained within two years of the date of issuance of the building permit. Time frames do not change with successive owners. The Community Development Coordinator may grant an extension of time for a period not to exceed one year and only within the original period of validity. The Community Development Board may approve one additional extension of time after the Community Development Coordinator's extension to initiate a building permit application. The issuance of this Development Order does not relieve you of the necessity to obtain any building permits or pay any impact fees that may be required. In order to facilitate the issuance of any permit or license affected by this approval, please bring a copy of this letter with you when applying for any permits or licenses that require this prior development approval. Additionally, an appeal of a Level Two approval (Flexible Development) may be initiated pursuant to Section 4-502.B by the applicant or by any person granted party status within 14 days of the date of the Community Development Board meeting. The filing of an application/notice • • September 22, 2005 Stephen B. Lafferty, AIA - Page Three of appeal shall stay the effect of the decision pending the final determination of the case. The appeal period for your case expires on October 4, 2005. If you have any questions, please do not hesitate to call Michael H. Reynolds, AICP, Planner III, at 727-562-4836. You can access zoning information for parcels within the City through our website: www.clearwater-fl.com. Sincerely, Michael Delk, tCP Planning Director S: (Planning DepartmentlC D BIFLEX (FLD)Unactive or Finished Applications Wetty N 1200 -Homeless Emergency Project (C) - 9-20-05 - MHR - Approved0evelopment Order.doc I I • r Sep. 26 2005 03:13PM YOUR LOGO, CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 i NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 93995777 Sep.26 03:11PM 01'34 SND 04 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP=FAX (435-7329). i I i Sep. 26 2005 03:13PM YOUR LOGO CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 97916751 Sep.22 03:24PM 01' 38 SND 03 OK 02 9791675197919979199 Sep.22 03:51PM 00' 46 RCV 00 OTHER FAX NOT RESPONDING 03 97916751 Sep.22 03:52PM 00' 51 SND 01 OK 04 93920497 Sep.22 04:13PM 00' 53 SND 02 OK 05 94466442 Sep.22 04:19PM 01' 12 SND 01 OK 06 919549666259 Sep.22 04:28PM 05' 02 SND 14 OK 07 97815631 Sep.22 04:38PM 01' 18 SND 01 OK 08 912022897722 Sep.22 04:47PM 00' 16 SND 00 NO DOCUMENT 09 95624894 Sep.22 10:30PM 00' 53 SND 01 OK 10 94430338 Sep.23 08:23AM 02' 27 SND 03 OK 11 913124319985 Sep.23 09:22AM 00' 43 SND 01 OK 12 912022897722 Sep.23 09:24AM 00' 59 SND 01 OK 13 7274648212 Sep.23 10:13AM 00' 52 RCV 03 OK 14 97862987 Sep.23 10:38AM 00' 58 SND 01 OK 15 94463741 Sep.23 10:53AM 00' 56 SND 02 OK 16 917706195611 Sep.23 11:07AM 00' 53 SND 02 OK 17 97252196 Sep.23 11:23AM 00' 43 SND 02 OK 18 97852370 Sep.23 12:53PM 00' 16 SND 00 PRESSED THE STOP KEY 19 <FAX # NOT AVAIL.> Sep.23 02:15PM 00' 53 RCV 02 OK 20 7274466626 Sep.23 02:22PM 00' 41 RCV 02 OK 21 94616916 Sep.23 03:01PM 01' 48 SND 02 OK 22 95624894 Sep.23 09:33PM 00' 54 SND 01 OK 23 94466442 Sep.26 08:37AM 03' 36 SND 08 OK 24 94444496 Sep.26 08:45AM 00' 41 SND 00 OTHER FAX NOT RESPONDING 25 94428470 Sep.26 11:34AM 00' 34 SND 01 OK 26 94468036 Sep.26 01:16PM 01' 17 SND 02 OK 27 <FAX # NOT AVAIL.> Sep.26 02:17PM 00' 28 RCV 01 OK 28 97813345 Sep.26 03:00PM 01' 52 SND 05 OK 29 97813345 Sep.26 03:04PM 01' 53 SND 05 OK 30 93995777 Sep.26 03:11PM 01' 34 SND 04 OK FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-FiELP-FAX 0435-73291. FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT 100 S. MYRTLE AVE., 2"d Floor CLEARWATER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 FAX: 7 7 Phone: FROM: 111/Ae- c?/Lc?IBJ Phone: DATE: 6 S' SUBJECT: /;tV Zrab f- 62 6 Z MESSAGE: e -"7klpl I r?Ze 45J /Zxxe5?!? if Zv U 10--60 NUMBER OF PAGES(INCLUDING THIS PAGE) l ? CDB Meeting Date Case Number: Agenda Item: Applicant: Representative: Address: September 20, 2005 FLD2005-07063 F14 Homeless Emergency Project, Inc. Stephen B. Lafferty, AIA 1200 North Betty Lane CITY OF CLEARWATER PLANNING DEPARTMENT STAFF REPORT GENERAL INFORMATION: REQUEST: Flexible Development application to permit the redevelopment and expansion of an existing residential shelter (including the expansion of the kitchen and dining area), in the Commercial District, to maintain the existing front, side and rear setbacks with the exception of a front (south) setback of 4 feet (to dumpster enclosure), and to permit off site parking, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G. EXISTING ZONING/LAND USE: C, Commercial District; CG, Commercial General Category PROPERTY SIZE: 0.43 acres PROPERTY USE: Current Use: Residential Shelter Proposed Use: Residential Shelter ADJACENT ZONING/LAND USES: North: Commercial District; Thrift Store West: Commercial District; Retail, storage East: Commercial District and Low Medium Density Residential District; Stevenson Creek, Single-family residential South: Commercial District; Church CHARACTER OF THE IMMEDIATE VICINITY: Single-family dwellings are to the east, with limited commercial uses on the east and west sides of North Betty Lane south of Stevenson Creek. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 1 i • ANALYSIS: Site Location and Existing Conditions: The 0.43-acre overall site is located on the northwest side of the intersection of North Betty Lane and Otis C. Greene Street. On site, there is an existing 8,750 square foot emergency shelter with 18 dwelling units. There is 2,020 square feet of kitchen and dining area. Proposal: What is proposed is an expansion of the kitchen and dining area to 4,003 square feet, new roofing, painting the building's exterior, landscaping, and re-allocation/designation of some parking spaces. Existing front, side, and rear setbacks will be maintained, with the exception of a front (south) setback to a dumpster enclosure. Off-site parking will be provided. Code Enforcement Analysis: There are no outstanding enforcement issues associated with this site. rnA4PT TANd-F W1TT4 CTANnARnQ ANTI CPITF.RIA• lCP?tinnc 7_7M 1 nnrd 7_7fiAl- STANDARD PROPOSED CONSISTENT INCONSISTENT MAXIMUM FLOOR N/A X AREA RATIO (FAR) 0.55 /A IMPERVIOUS 0.79 X SURFACE RATIO ISR) 0.95 LOT AREA 0.43 acres; 18,730 square feet X minimum /A LOT WIDTH 125 feet X (minimum) /A FRONT SETBACK four feet to dumpster enclosure X* 25 feet) /A four feet to building REAR SETBACK (20 0.6 feet to building X* feet /A) SIDE SETBACK (10 West: 0.6 feet to building X* feet /A) East: 5.3 feet to building HEIGHT (25' 18 feet X maximum /A PARKING (N/A) 2 spaces X *See Analysis. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 2 f COMPLIANCE WITH COMPREHENSIVE INFILL CRITERIA (Section 2-704 C): Consistent Inconsistent I. The development or redevelopment of the parcel proposed for X development is otherwise impractical without deviations from the use, intensity and develo ment standards. 2. The development of the parcel proposed for development as a X Comprehensive Infill Redevelopment Project will not reduce the fair market value of abutting properties. 3. The uses within the Comprehensive Infill Redevelopment Project are X otherwise permitted in the City of Clearwater. 4. The use or mix of uses within the Comprehensive Infill X Redevelopment Project is compatible with adjacent land uses. 5. Suitable sites for development or redevelopment of the uses of mix of X uses within the Comprehensive Infill Redevelopment Project are not otherwise available in the City of Clearwater. 6. The development of the parcel proposed for development, as a X Comprehensive Infill Redevelopment Project will upgrade the immediate vicinity of the parcel proposed for development. 7. The design of the proposed Comprehensive Infill Redevelopment X Project creates a form and function that enhances the community character of the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. 8. Flexibility in regard to lot width, required setbacks, height and off- X street parking are justified by the benefits to community character and the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. 9. Adequate off-street parking in the immediate vicinity according to the X shared parking formula in Division 14 of Article 3 will be available to avoid on-street parking in the immediate vicinity of the parcel proposed for development. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 3 COMPLIANCE WITH GENERAL STANDARDS (Section 3-913): Consistent Inconsistent 1. Development of the land will be in harmony with the scale, bulk, X coverage, density and character of adjacent properties. 2. Development will not hinder or discourage development and use of X adjacent land and buildings or significantly impair the value thereof. 3. Development will not adversely affect the health or safety of persons X residing or working in the neighborhood. 4. Development is designed to minimize traffic congestion. X 5. Development is consistent with the community character of the X immediate vicinity. 6. Design of the proposed development minimizes adverse effects, X including visual, acoustic and olfactory and hours of operation impacts on adjacent properties. SUMMARY AND RECOMMENDATION: The Development Review Committee reviewed the application and supporting materials on August 4, 2005. The Planning Department recommends APPROVAL of the Flexible Development application to permit the redevelopment and expansion of an existing residential shelter (including the expansion of the kitchen and dining area), in the Commercial District, to maintain the existing front, side and rear setbacks with the exception of a front (south) setback of 4 feet (to dumpster enclosure), and to permit off site parking, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G. for the site at 1200 North Betty Lane, based upon the recommended findings of fact, conclusions of law and conditions of approval as follows: Recommended Findings of Fact: 1. Subject property is 18,730 square feet (0.43 acres), approximately 125 feet wide; 2. The site is within the Commercial (C) District and the Commercial General (CG) future land use plan classification; 3. Applicant seeks to redevelop and expand an existing residential shelter, including the expansion of the kitchen and dining area, maintaining the existing front, side, and rear setbacks with the exception of the front (south) setback of four feet (to dumpster enclosure) and to permit off-site parking as a Comprehensive Infill Project under the provisions of Section 2- 704.C and as a Comprehensive Landscape Program, under the provisions of Section 3- 1202.G.; Other improvements include the provision of a loading space and handicap parking space at the front of the building, landscaping, new roofing, exterior painting, and bicycle parking; and 4. No other changes are proposed for the site or building. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 4 • Recommended Conclusions of Law: 1. Staff finds the proposal compliant with the General Purposes of the Code per Sections 1- 103.A, B.2, E.9 and E.12; 2. Staff finds the proposal compliant with the Flexible Development criteria per Section 2-704.C 3. Staff further finds the proposal compliant with the Flexible Development criteria as a Comprehensive Infill Redevelopment Project per Section 2-704.C and General Applicability Standards per Section 3-913; and 4. Staff recommends Board approval of FLD2005-05038 based on the recommended findings of fact and conditions as stated. Recommended Conditions of Approval: 1. That all signage meet Code, including the removal/redesign of any existing nonconforming signs, through building permits prior to the issuance of a certificate of occupancy for the applicable site; 2. All Fire Department comments are to be met prior to any building permit issuance; 3. That a Right-of-Way utilization permit be obtained prior to building permit issuance; 4. That prior to building permit issuance, the site plan be revised, to the satisfaction of City staff, to show 23 feet in length parallel parking spaces; and 5. That the applicant make payment in lieu fir stormwater attenuation prior to building permit issuance. Prepared by: Planning Department Staff Michael H. Reynolds, AICP, Planner III ATTACHMENTS: Aerial Photograph of Site and Vicinity Location Map Future Land Use Map Zoning Atlas Map Application S: (Planning DepartmentlC D BIFLEX (FLD)IPending casesl Up for the next CDBIBetty N. 1200 - Homeless Emergency Project (C) - 9-20-05 CDB - MHRIBetty N 1200 Staff Report.doc Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 5 r Sep. 16 2005 03:53PM YOUR LOGO CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 93995777 Sep.16 03:51PM 02'16 SND 06 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX (435-7329). LONG RANGE PLANNING DEVELOPMENT REVIEW CITY OF CLEARWATER PLANNING DEPARTMENT POST OFFICE BOX 4748, CLEARWATER, FLORIDA 33758-4748 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAx (727) 562-4576 March 16, 2004 Ms. Barbara Green, Executive Director Homeless Emergency Project, Inc. 1120 North Betty Lane Clearwater, FL 33755 Re: Grant Application Information regarding 1200 North Betty Lane Dear Ms. Green: The subject property is zoned C, Commercial District and is consistent with its underlying land use designation of Commercial General Category. The current use of the property is deemed to be a Residential Shelter under the provisions of the Community Development Code, which is not a permitted use within the Commercial District. It is the Planning Department's understanding that you desire to replace the existing mobile home used as a kitchen and dining facility with a more permanent structure for the same purpose meeting Code requirements. In order to accomplish your proposal, a Comprehensive Infill Redevelopment Project request will be required to be submitted for approval by the Community Development Board after public hearing, and may include any setback, parking and buffering reductions necessary. Attached is a copy of the current Commercial District regulations, as contained within the Community Development Code. Zoning information is available through. the City's website at www.Lnyclearwater.com. Should you need additional assistance, feel free to contact me at 727-562-4504. \Sincerely, (? 1 ,,? (? . v v ?? ? ` • W ?L..?.7?C.,0 Wayne M' Wells Senior Planner Attachment BRIAN J. AUNGST, MAYOR-COMMISSIONFR HOPI' HAMILTON, VICE MAYOR-COMMISSIONFR WHITNEY GRAY, COMMISSIONER FRANK HIBBARD, COMMISSIONER ® BII.I. JONSON, COMMISSIONER "EQUAL. EMPLOYMENT AND AFFIRMATIVI? ACTION EMPLOYER" • Uhtz? 0._ ,r-A? rj;w?4-j • ?S Zo?d ?- ?k V-? ? Q ??tleh t> I(- 0. vxx v „e?-+ -?- ?, I, , ?,t .1 ?x Gx dl?c, s ? ?j0 fib- ? l?••l., CJi? a f w ?. ? ? ? 3-37 5-C c.?? 5 (o Z . 0 3 4qa- X041 rela ) 41`6 - Sao V" LL 0 ater • FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT 100 S. MYRTLE AVE. CLEARWATER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 TO: FAX: ararI- 4a 7J 542-- '037 Phone: a`+1 9 0 + I FROM: Vl) 1?S Phone: ?}- DATE•_ N 1'RE: Z 0 O N• 2 MESSAGE: NUMBER OF PAGES(INCLUDING THIS PAGE) 2- Mar. 16 2004 04:26PM YOUR LOGO CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 94434875 Mar.16 04:25PM 01'03 SND 02 OK TO TURN OFF REPORT, PRESS 'MENU' #te4. THEN SELECT OFF BY USING '+' OR FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX (435-7329). It .. 0 Mar. 16 2004 04:25PM YOUR LOGO : CityOfClearwater-Plan Dept YOUR FAX NO. : 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 95624037 Mar.16 04:23PM 01'05 SND 02 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX (435-7329). ary `? ry LOT 10 nh ?n LOCK C n? GONG- BLOCK WALL 8q 29'23" E (M) 125.03' (M) ULF 125' (P) o?l n??p .6'E. 119.1' __ vry 5.4' LO ?' q 1 STORY APARTMENT BUILDING BLOCK C FLOOR Fl F\/. = 13.62 vA oyry 11.3' 47.4' 22.4' 09 62 GOV. CON 41, ?I1 19.84 GONG. 51DEWALK 13 O 11.0' ASPHALT lA ?,PAVEMENT ')° ^ O n IJ 22.8' % ? aory m ? O v LOT 8 BLOCK C < 3 rnl 3.3' rn n . ^? - 06 rn d ja -'10 A Ph z A D D O "of 71 lf? < N N = fit ry Nl y D r rn r ;z SITE PLAN ZI z 5--ale 1 = 20'ti rn NEYV HEP ?' -• ,?. DINNING ?o _ tiGl I Ul x FACILITY O I ? 9 4 A'l 22-5- 22--4' - -Q ---- - - ------ - LOT---- 3 ?GP BLO K C Po EL = ,? FLOOR ,ry o0 981 NO ' 13. :ti ry?;9 , ELEV. = e -- X 1 x , ' 13.65 13.65 l N 24.'75.3' I 4. Q P I ry S.N.D. p. - ? I PP PP 5 ;2q'23" W (M) 125.04' (M) ,oe A 5 P H A L T /T, 5.,?„?b„ O t2 ??a D R I V E W A Y TRIPLE OO Ob ?" I o L °ry 14 1?1? 1?ry . , YY,/ 7 La5ALLE 5T. -- - -- - -- - -- - ---- ? (MADISON 5T. 60' R/)V PER PLAT) " -- - - - --- - - - ? ?? - ? I woexT.aLE ?KXM ? ? w,e.cxaw w -- i aa•Nx ?.?La mu. ?, -- ;"r'Nj za•Dxeo•L :e-z,ew eaw 3a•Nx _._._____ ._.. na snaD r? s aD z Dxae•L - '- e3- N oN e .' 1i,i"Al ------- - ---- - - TFIT :nl r1w I I I FIRST FLOOR PLAN ------- scale: 1/8" = r-a' A- ? OF NEW DINNING FACILITIES FOR THE HOMELE55 EMERGENCY PROJECT MYERS & ASSOCIATES ARCHITECTURE AIA PA 9170 OAKHURST ROAD SUITE 3B SEMINOLE, FLORIDA JAY F. MYERS 4959 A_? , FLORIDA 727 - 595 - 7100 FAX 727 - 595 - 7138 myersarch@ix.netcom.com # AA -0003461 f J -a SEATING FOR 132 0 5ECOND FLOOR PLAN sowe: ve, _:2 ' NEW PINNIN(9 FACILITIES FOR THE HOME Z55 EMERGENCY PROJECT MyM do A%OMTO ARCHITECTURE AM PA 9170 OAKHURST ROAD SUITE 3B SEMINOLE, FLORIDA JAY F. MYERS 4959 A-.2 XXXXXXXXXXXX, FLORI37A 727 - 595 - 7100 FAX 727 - 595 7138 myersarch®ix.netccom om. # AA -0003461 O O 0 0 ORIGINAL LAFFERTY ARCHITECTURE GROUP LLC 11414 Seminole Blvd, Suite 5 Largo, FL 33778 P: 727-399-1300 F: 727-399-5777 info@LaffertyARCH.com August 12, 2005 Mike Reynolds City of Clearwater Planning Department 100 South Myrtle Ave, 2nd Floor Clearwater, FL 33756 Re: Homeless Emergency Project 1120 N. Betty Lane Clearwater, FL 33755 Case Number: FLD2005-07063 RECHWE) AUG 12 2005 PLANNING DEPARTMENT CIWOF CLEARWATER Dear Mr. Reynolds: The following is a response to the DRC agenda comments on the above-mentioned project. Please circulate this letter with the revisions. If you have any questions, please do not hesitate to contact me at the numbers listed above, or via e-mail (also above). General Engineering: Comment: Prior to Community Development Board, show on the plan the location of the grease interceptor if required for this use. Response: The grease interceptor location has been added to the Drawings. Environmental• Comment: See stormwater conditions Response: No response necessary. Comment: This DRC review by Fire is not an approval or review of any construction plans or documents other than site work. Please acknowledge PRIOR TO CDB. Response: Acknowledged. Plans for a building permit will be submitted separately. Comment: The entire property, new dining structure and 18 dwelling units, must be protected by a fire sprinkler system as per NFPA-13. Please acknowledge PRIOR TO CDB. Response: Acknowledged - required per FFPC 2004 (NFPA 101) Chapter 28. Comment: Show on the site plan the FDC (Fire Department Connection) located at least 15 feet off the building and within 40 feet of a fire hydrant PRIOR TO CDB. Response: A location for the proposed FDC has been shown on the Drawings. Due to extremely tight site constraints, the maximum distance the FDC can be located away from the building is approx. 6'. The proposed location is directly across the street from an existing Fire Hydrant, approx. 70 feet away. Site constraints on this site make the installation of an additional Hydrant impractical. Responses to DRC Comments Homeless Emergency Project Page 2 of 4, 8/12/2005 ORIGINAL Comment: Where underground water mains and hydrants are to be installed, they shall be installed, completed, and in service prior to construction as per NFPA-241. Please acknowledge PRIOR TO CDB. Response: Acknowledged. Underground piping shall be installed per NFPA-241 (Standard for Safeguarding Construction, Alteration, and Demolition Operations, 2004 Edition). Comment: Clearances of 7 1/2 feet in front of and to the sides of the fire hydrant, with a 4-foot clearance to the rear of the hydrant, are required to be maintained as per NFPA-1, please acknowledge PRIOR TO CDB. Response: Proposed layout utilizes existing fire hydrants. Proper clearances are provided. Comment: Fire Department Connections shall be identified by a sign that states "No Parking, Fire Department Connection" and shall be designed in accordance with Florida Department of Transportation standards for information signage and be maintained with a clearance of 7 1/2 feet in front of and to the sides of appliance, as per Florida Fire Prevention Code 2004 edition. Please acknowledge PRIOR TO CDB. Response: Acknowledged. The proposed FDC location is on Betty Lane and highly unlikely for parking to occur in front of the FDC. Harbor Master• No Comments No Comments i AUG 1.2005 ; . Land Resources: No Comments ' PLAPVt 5 Lr ?_; I i`iC?l Landsca ip No Comments Parks and Recreation: Comments: No issues - homeless shelter replacing existing dining hall with permanent structure. Response: No response required. Stormwater• Comments: Project is considered redevelopment by City of Clearwater Stormwater Criteria and therefore redeveloped area must meet current criteria for water quality and attenuation. This requirement shall be addressed prior to CDB. Response: Stormwater calculations are shown on the drawings. Stormwater management for water quality has been added to the design in accordance with City of Clearwater Stormwater Drainage Design Criteria. Attenuation on this site is not practical due to the limited site area. The Project shall pay into the city fund in lieu of providing attenuation facilities. ARCHITECTURAL DESIGN SERVICES N STRATEGIC MASTERPLANNING N PROJECT MANAGEMENT LAFFERTY ARCHITECTURE GROUP LLC www.LAFFERTYARCH.COM FL LIC AA 26000901 Responses to DRC Comments *ORIGINAL Homeless Emergency Project Page 3 of 4, 8/12/2005 Solid Waste: Comments: That dumpster enclosure(s) needs to be constructed to City specifications. As a 3yd Dumpster exists on property now. The Black Barrels shown on drawing are not associated with this address. Response: Acknowledged. A dumpster enclosure for a 3-cubic yard dumpster has been shown on the drawings and shall be constructed to City specifications. Due to site constraints, this enclosure is proposed to be located within the required setback, but aligning with adjacent existing building on site. Traffic Engineering: Comments: Proposed parking spaces backing into right-of-way is not allowed under Community Development Code Section 3-1402 C. TO BE ADDRESSED PRIOR TO CDB. Response: Parking has been reconfigured so backing into ROW is not required. Comments: Driveway does not meet minimum spacing requirements of 125' from driveway edge of curb to intersection edge of curb. TO BE ADDRESSED PRIOR TO CDB. Response: Existing parking and drive is within 125' from intersection. Providing the required distance is impossible, as the lot is only 125.03' wide and existing building configurations prohibit drive locations in any other location. Parking has been reconfigured so back-up is not required out of the site, but parallel parking is utilized for only 2 spaces. Notes have been added to the Drawings and application to explain unique parking requ e n !n Plannina• Comments: Provide plan set index to plan sheets. Response: Index has been added to the Drawings. AUG 12 2005 PLANNk' Comments: On the application form, state what the request is specifically, referencing, w(1ijOF C `- code(s) are being requested for deviation, including parking requirements. Response: Application form, Attachment "A" has been revised to show specific codes that are requested for flexibility consideration. Comments: Improve the legibility of the detail shown on the site plan. Response: The Site Plan has been increased in scale, shading has been added, and additional notes have been added to more clearly describe the proposed Scope Of Work. Comments: Provide 8 1/2 by 11" color landscape plan. Response: A color landscape plan has been provided. Comments: Provide greater detail to justify the request, including back-out parking. Response: Parking has been reconfigured so back-up is not required out of the site, but parallel parking is utilized for only 2 spaces. Notes have been added to the Drawings and application to explain unique parking requirements Comments: Increase the plan scale. Response: The Site Plan has been increased in scale, shading has been added, and additional notes have been added to more clearly describe the proposed Scope Of Work. ARCHITECTURAL DESIGN SERVICES - STRATEGIC MASTERPLANNING o+ PROJECT MANAGEMENT LAFFERTY ARCHITECTURE GROUP LLC www.LAFFERTYARCH.com FL LIc AA 26000901 Responses to DRC Comments • Homeless Emergency Project ORIGINAL Page 4 of 4, 8/12/2005 Comments: Provide a "master Plan" of all buildings/sites within this vicinity that are related to the purpose of this site. Such master plan will be helpful in understanding parking needs and availability and other connectivity issues. Response: A "Master Plan" of all buildings/sites within this vicinity that are related to the purpose of this site has been added to the submittal set. Comments: The site plan needs to clearly indicate what is proposed as new versus what will be kept as is. What is changing, other than internal building and exterior building skin and roof changes to the existing outer buildings? Response: The Site Plan has been increased in scale, shading has been added, and additional notes have been added to more clearly describe the proposed Scope Of Work. Comments: Photographs and renderings need to clearly delineate what is new versus what is proposed to remain unchanged. Response: On the photographs and elevation additional notes have been added to more clearly describe the proposed Scope Of Work. We believe that these comments fully respond to all DRC comments. Again, if you have any additional questions or concerns, please do not hesitate to contact us either by telephone or by e- mail and we look forward to proceeding to the Community Development Board on 9/20/05. *Sincerely, en B. Lafferty AIA FL ARCH AR12265/ID3614 SBL/jcs Cc: Barbara Green, Homeless Emergency Project Cry R AUG 22 20Q5 '"? PLANNING g "F % ARCHITECTURAL DESIGN SERVICES - STRATEGIC MASTERPLANNING - PROJECT MANAGEMENT LAFFERTY ARCHITECTURE GROUP LLC www.LAFFERTYARCH.COM FL LIC AA 26000901 0 0 Icarw cater FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT TO: 100 S. MYRTLE AVE., 2nd Floor CLEARWATER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 FAX: L3?? ?7 7 7 FROM: A/ ?1e Reyes 1106 Phone: DATE: SUBJECT: G? Zv?g J'- 6 ? 6 MESSAGE: .ate ?4 ?2 C (/ sof NUMBER OF PAGES(INCLUDING THIS PAGE) I/ 10.45 am Case Number: FLD2005-07•-- 1200 N BETTY LN Owner(s): Homeless Emergency Project 1120 N Betty Ln Clearwater, Fl 33755 TELEPHONE: 727-442-9041, FAX: No Fax, E-MAIL: No Email Representative: Stephen Lafftery 11414 Seminole Blvd Largo, F133778 TELEPHONE: 727-399-1300, FAX: 727-399-5777, E-MAIL: No Email Location: 0.43 acres located on the northwest side of the intersection of Betty Lane and Otis C. Greene Street. Atlas Page: 269B Zoning District: C, Commercial Request: Application for Flexible Development approval to permit a residential shelter as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-704.C. and as part of a Comprehensive Landscape Program under the provisions of Section 3-1202.G. Proposed Use: Assisted living facilities Neighborhood Clearwater Neighborhoods Coalition Association(s): Clearwater, F133761 2544 Frisco Drive TELEPHONE: 727-725-3345, FAX: No Fax, E-MAIL: Djw@gte.net Neighborhood North Greenwood Association, Inc. Association(s): Clearwater, F133755 1201 Douglas Road TELEPHONE: 560-4382, FAX: No Fax, E-MAIL: WADENWADE@AOL.COM Neighborhood Country Club Estates Neighborhood A Association(s): Clearwater, F133755 800 N Betty Lane TELEPHONE: 298-0096, FAX: No Fax, E-MAIL: mark.woolridge@palmettogba.com Presenter: Mike Reynolds, Planner III Attendees Included: Neil Thompson, Mike Reynolds, Scott Rice, Tom Glenn, Anne Blackburn, Rick Albee The DRC reviewed this application with the following comments: General Engineering: 1 . 1. Prior to Community Development Board, show on the plan the location of the grease interceptor if required for this use. General Note: DRC review is a prerequisite for Building Permit Review, additional comments may be forthcoming upon submittal of a Building Permit Application. Environmental: Fire: See stormwater conditions Development Review Agenda -Friday, August 5, 2005 - Page 21 1 . ***PLEASE NOTE*** REVIEW AND APPROVAL BY THE APHORITY HAVING JURISDICTION SHALL NOT RELEIVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE 2004 EDITION. This DRC reveiw by Fire is not an approval or review of any construction plans or documents other than site work. Please acknowledge PRIOR TO CDB. 2. The entire property, new dining structure and 18 dwelling units, must be protected by a fire sprinkler system as per NFPA-13. Please acknowledge PRIOR TO CDB. 3 . Provide and show on the site plan a hydrant within 300 ft of the building. Please acknowledge PRIOR TO CDB. 4. Show on the site plan the FDC (Fire Department Connection) located at least 15 feet off the building and within 40 feet of a fire hydrant PRIOR TO CDB. 5. Where underground water mains and hydrants are to be installed, they shall be installed, completed, and in service prior to construction as per NFPA-241. Please acknowledge PRIOR TO CDB. 6. Clearances of 7 1/2 feet in front of and to the sides of the fire hydrant, with a 4 foot clearance to the rear of the hydrant, are required to maintained as per NFPA-1, please acknowledge PRIOR TO CDB. 7. Fire Department Connections shall be identified by a sign that states "No Parking, Fire Department Connection" and shall be designed in accordance with Florida Department of Transportation standards for information signage and be maintained with a clearance of 7 1/2 feet in front of and to the sides of applliance, as per Florida Fire Prevention Code 2004 edition. Please acknowledg PRIOR TO CDB. Harbor Master: No Comments Legal: No Comments Land Resources: No Comments Landscaping: No Comments Parks and Recreation: 1 . No issues - homeless shelter replacing existing dining hall with permanent structure Stormwater: 1 . Project is considered redevelopment by City of Clearwater Stormwater Criteria and therefore, redeveloped area must meet current criteria for water quality and attenuation. This requirement shall be addressed prior to CDB. Solid Waste: 1 . That dumpster enclousure(s) needs to be constructed to City specifications. As a 3yd Dumpster exists on property now. The Black Barrels shown on drawing are not asscociated with this address. Traffic Engineering: 1 . Proposed parking spaces backing into right-of-way is not allowed under Community Development Code Section 3-1402 C.. 2. Driveway does not meet minimum spacing requirements of 125' from driveway edge of curb to intersection edge of curb. All of the above to be addressed prior to CDB. Planning: Development Review Agenda -Friday, August 5, 2005 - Page 22 1 . 1. Provide plan set index to plan sheets. 2. On the application form, state what the request is specifically, referencing what code(s) are being requested for deviation, including parking requirements. 3. Improve the legibility of the detail shown on the site plan. 4. Provide 8 1/2 by 11" color landscape plan. 5. Provide greater detail to justify the request, including back out parking. 2. Increase the plan scale. 3 . Provide a "master plan" of all buildings/sites within this vicinity that -are related to the purpose of this site. Such master plan will be helpful in undestanding parking needs and availability and other connectivity issues. 4. The site plan needs to clearly indicate what is proposed as new versus what will be kept as is. What is changing, other than internal building and exterior building skin and roof changes to the existing. outer buildings? 5. Photographs and renderings needs to clearly delineate what is new versus what is proposed to reamin unchanged. Other: No Comments Notes: Development Review Agenda -Friday, August 5, 2005 - Page 23 v • Aug. 01 2005 03:37PM YOUR LOGO CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 93995777 Aug.01 03:36PM 01'26 SND 04 OK TO TURN OFF REPORT, PRESS 'MENU' #t04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEBE CALL 1-800-HELP-FAX (435-7329). a 0 Reynolds, Mike From: Reynolds, Mike Sent: Tuesday, July 19, 2005 12:50 PM To: 'steve@laffertyarch.com' Cc: Watkins, Sherry Subject: RE: FLD2005-07063 - Homeless Emergency Project Steve, The letter of completeness was sent by FAX and regular mail today. I am forwarding your time of day scheduling request to Sherry Watkins. Sherry schedules the cases onto the DRC agenda. We will try to help you, regarding the agenda time. Thank you for your e-mail. Mike Michael H. Reynolds, AICP Planner III Planning Department City of Clearwater Tel. # 727-562-4836 E-mail: mike.reynolds@myclearwater.com -----Original Message----- From: Steve Lafferty [maiIto:steve@laffertyarch.com] Sent: Monday, July 18, 2005 8:26 PM To: Reynolds, Mike Subject: RE: FLD2005-07063 - Homeless Emergency Project Mike - Thanks for your call. I do appreciate it very much. I do not want to ask for anything special, but if they could schedule this DRC review for later in the day after lunch, it would be greatly appreciated. Thanks again. -Steve Lafferty steve@LaffertyARCH.com ...Creating Spaces that Facilitate Impacts upon Peoples' Lives... -----Original Message----- From: Steve Lafferty [mailto:steve@laffertyarch.com] Sent: Monday, July 18, 2005 3:50 PM To: Mike Reynolds Subject: FLD2005-07063 - Homeless Emergency Project Good Afternoon, Mike Just quickly following up to make sure that the Homeless Emergency Project application was received and deemed "Complete...." Could you let me know how it stands and if the DRC has decided or not to add additional meetings to their schedule. THANKS! Stephen B. Lafferty, AIA Lafferty ARCHitcture Group LLC - Architectural Services Lafferty ARCHitecture LLC - Project Management Services 11414 Seminole Blvd., Suite 5 Largo, FL 337778 P - 727-399-1300 F - 727-399-5777 C - 727-647-8697 www.LaffertyARCH.com (professional) www.laffers.com (personal) ...Creating Spaces that Facilitate Impacts upon Peoples' Lives... Author of Project Management @ NetSpeed, available at www.booksurge.com 0 0 Reynolds, Mike From: Steve Lafferty [steve@laffertyarch.com] Sent: Monday, July 18, 2005 8:26 PM To: Reynolds, Mike Subject: RE: FLD2005-07063 - Homeless Emergency Project Mike - Thanks for your call. I do appreciate it very much. I do not want to ask for anything special, but if they could schedule this DRC review for later in the day after lunch, it would be greatly appreciated. Thanks again. -Steve Lafferty steve@LaffertyARCH.com ...Creating Spaces that Facilitate Impacts upon Peoples' Lives... -----Original Message----- From: Steve Lafferty [mailto:steve@laffertyarch.com] Sent: Monday, July 18, 2005 3:50 PM To: Mike Reynolds Subject: FLD2005-07063 - Homeless Emergency Project Good Afternoon, Mike Just quickly following up to make sure that the Homeless Emergency Project application was received and deemed "Complete...." Could you let me know how it stands and if the DRC has decided or not to add additional meetings to their schedule. THANKS! Stephen B. Lafferty, AIA Lafferty ARCHitcture Group LLC - Architectural Services Lafferty ARCHitecture LLC - Project Management Services 11414 Seminole Blvd., Suite 5 Largo, FL 337778 P - 727-399-1300 F - 727-399-5777 C - 727-647-8697 www.LaffertyARCH.com (professional) www.laffers.com (personal) ...Creating Spaces that Facilitate Impacts upon Peoples' Lives... Author of Project Management @ NetSpeed, available at www.booksurge.com • 9 Reynolds, Mike From: Steve Lafferty [steve@laffertyarch.com] Sent: Monday, July 18, 2005 3:50 PM To: Reynolds, Mike Subject: FLD2005-07063 - Homeless Emergency Project Good Afternoon, Mike Just quickly following up to make sure that the Homeless Emergency Project application was received and deemed "Complete...." Could you let me know how it stands and if the DRC has decided or not to add additional meetings to their schedule. THANKS! Stephen B. Lafferty, AIA Lafferty ARCHitcture Group LLC - Architectural Services Lafferty ARCHitecture LLC - Project Management Services 11414 Seminole Blvd., Suite 5 Largo, FL 337778 P - 727-399-1300 F - 727-399-5777 C - 727-647-8697 www.LaffertyARCH.com (professional) www.laffers.com (personal) ...Creating Spaces that Facilitate Impacts upon Peoples' Lives... Author of Project Management @ NetSpeed, available at www.booksurge.com LL 0 } learwater U FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT 100 S. MYRTLE AVE., 2nd Floor CLEARWATER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 TO: FAX: Vf- 1-7 7 7 Phone: FROM: Afe Phone: DATE: 6 Y' SUBJECT:/? ?- g , 6-7 G/ ) MESSAGE: 'et Ao?? Gv? lei, NUMBER OF PAGES(INCLUDING THIS PAGE) 11 .It i E CITY OF C LEARWATER PLANNING DEPARTMENT POST OFFICE BOX 4748, CLEARWATER, FLORIDA 33758-4748 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAx (727) 562-4865 LONG RANGE PLANNING DEVELOPMENT REVIEW July 18, 2005 Mr. Stephen B. Lafferty, AIA Lafferty Architecture Group LLC 11414 Seminole Boulevard, Suite 5 Largo, FL 33778 SUBJECT: FLD2005-07063; 1200 N. Betty Lane; Letter of Completeness Dear Mr. Lafferty: After a preliminary review of your application submittal materials, your application has been determined to be complete. The Development Review Committee (DRC) will consider your application for sufficiency on August 4, 2005, in the Planning Department conference room (216) at 100 South Myrtle Avenue. Please contact Sherry Watkins, Administrative Analyst, at 727- 562-4582 no earlier than one week prior to the meeting date for your approximate agenda time. You or your representative must be present at this meeting. If you have any question, please contact me at tel. # 727-562-4836 or mike.renolds@myclearwater.com Sincerely, Michael H. Reynolds, AICP Planner III S: IPlanning DepartmentlC D BIFLEX (FLD)IPending casesI Up for the next DRCIBetty N. 1200 -Homeless Emergency Project - MHR I Completeness letter.doc FRANK HIBBARD, MAYOR BILL JONSON, VICE-MAYOR JOHN DORAN, COUNCIL\IEMBER HOYT HAMILTON, COUNCHAFMBER ® CARLEN A. PETERSEN, COUNCI11AF-MBER "EQUAL EMPLOYMENT AND AFFIRMATIVI? ACTION EMPLOYER" Jul. 19 2005 11:17AM YOUR LOGO CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 93995777 Ju1.19 11:16AM 00'56 SND 02 OK TO TURN OFF REPORT, PRESS 'MB4J' t#04. THEN SB_ECT OFF BY USING '+' OR FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL i-800-HELP-FAX (435-7329). C ITY OF C LEARWATE R PLANNING DEPARTMENT POST OFFICE BOX 4748, CLEARWATER, FLORIDA 33758-4748 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAx (727) 562-4865 LONG RANGE PLANNING DEVELOPMENT REVIEW July 18, 2005 Mr. Stephen B. Lafferty, AIA Lafferty Architecture Group LLC 11414 Seminole Boulevard, Suite 5 Largo, FL 33778 SUBJECT: FLD2005-07063; 1200 N. Betty Lane; Letter of Completeness Dear Mr. Lafferty: After a preliminary review of your application submittal materials, your application has been determined to be complete. The Development Review Committee (DRC) will consider your application for sufficiency on August 4, 2005, in the Planning Department conference room (216) at 100 South Myrtle Avenue. Please contact Sherry Watkins, Administrative Analyst, at 727- 562-4582 no earlier than one week prior to the meeting date for your approximate agenda time. You or your representative must be present at this meeting. If you have any question, please contact me at tel. # 727-562-4836 or mike.reygolds@myclearwater.com Sincerely, Michael H. Reynolds, AICP Planner III S:Tlanning DepartmenIlC D BIFLEX (FLD) Tending cases )Up for the next DRCIBetty N. 1200 -Homeless Emergency Project - MHRICompleteness letter roc FRANK HIBBARD, MAYOR BILL. JONSON, VLCF-MAYOR JOHN DORAN, COUNCIL INIFNIBER HOYT HAMICCON, COUNCILMFMBER ink CARLFN A. PFTFRSI?N, COUNCIL MEMBER "EQUAL. EMPLOYMENT AND AFFIRMA iii: ACTION EMPLOYER" 0. 9 r Clearwater U FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT 100 S. MYRTLE AVE., 2nd Floor CLEARWATER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 TO: FAX: 3??-- X77 7 Phone: FROM: 1??zd Phone: CITE Z ?6'? DATE: SUBJECT: -Z a,r- O? G 43 MESSAGE: U Q ??.? l-C?r?/.?.? ?d???er, NUMBER OF PAGES(INCLUDING THIS PAGE) 9 0 ?; CITY OF C LEARWA'TER "We = W ?v PLANNING DEPARTMENT POST OFFICE BOX 4748, CLEARWATER, FLORIDA 33758-4748 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAx (727) 562-4865 LONG RANGE PLANNING DEVELOPMENT REVIEW July 6, 2005 Mr. Stephen B. Lafferty, AIA Lafferty Architecture Group LLC 11414 Seminole Boulevard, Suite 5 Largo, FL 33778 RE: Application for Flexible Development approval to permit a residential shelter as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2- 704.C. and as part of a Comprehensive Landscape Program under the provisions of Section 3-1202.G.(Case Number FLD2005-07063, 1200 N. Betty Lane). Dear Mr. Lafferty: The Planning staff has reviewed your application for Flexible Development approval as listed above for property located at 1200 N. Betty Lane. After a preliminary review of the submitted documents, staff has determined that the application is incomplete. Section 4- 202 of the Community Development Code states that if an application is deemed incomplete, the deficiencies of the application shall be specified by Staff. No further development review action shall be taken until the deficiencies are corrected and the application is deemed complete. In order to stay on the current schedule for review for sufficiency by the Development Review Committee (DRC) on August 4, 2005, the following information is required to be submitted by 12:00 pm (Noon) on July 11, 2005 (should you be unable to meet this time frame, the next submittal deadline is July 29, 2005 [noon] to be reviewed for sufficiency by the DRC on September 1, 2005, if the application is deemed complete): The following items and/or information are required in order to make your application complete (submit one original and 14 copies): 1. Submit a Comprehensive Infill Redevelopment Flexible Development Application. The application form that you submitted is not for Comprehensive Infill. 2. On the application form, state what the request is specifically, referencing what code(s) are being requested for deviation, including parking requirements. FRANK HIBBARD, MAYOR BILL JONSON, VICE-MAYOR JOHN DORAN, C0lJNC11,11F\113FR HOY"I' HAMILTON, COUNCa1.MEMBER C,ARLEN A. PETFRSP.N, COUN;ILMEM BER "FQUAL EMPLOYMENT AND AFFIRMATIVI? ACTION EMPLOYER" July 6, 2005 Lafferty- Page 2 3. The site plan does not show setback distances by dimensional arrows (in linear feet) from property lines to pavement and building. 4. Address the stormwater application submittal requirements. 5. Adequate site data table needs to be provided on the site plan, stating all code requirements, what exists, and what is proposed. Please note that this letter addresses completeness items only. Sufficiency will be determined upon receipt of a complete and correct application form. If you have any questions, please do not hesitate to call me at 727-562-4836. You can access zoning information for parcels within the City through our website: www.myclearwater.com. Sincerely, -'oc irr Michael H. Reynolds, AICP Planner III S: (Planning Departmentl C D BIFLEX (FLD)IIncompletelBettyN. 1200- Homeless Emergency Project - MHRIBetty N. 1200 Incomplete Letter.doc 14 0 naermoin•ygy?g? Jul. 07 2005 10:31AM YOUR LOGO : CityOFClearwater-Plan Dept YOUR FAX NO. : 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 93995777 Jui.07 10:30AM 01'11 SND 03 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-FOP-FAX (435-7329). C I'T'Y OF C LEARWATER PI ANNING DEPARTMENT POST ClI`FICE I30X 4748, CLEARWATER, FLORIDA 33758-4748 Mu.NICIPAI. SERVICES BUILDING, 100 SOUTH MYRTLI. AVI NUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAX (727) 562-4865 LONG RANGE PLANNING DEVELOPMENT REVIEW July 6, 2005 Mr. Stephen B. Lafferty, AIA Lafferty Architecture Group LLC 11414 Seminole Boulevard, Suite 5 Largo, FL 33778 RE: Application for Flexible Development approval to permit a residential shelter as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2- 704.C. and as part of a Comprehensive Landscape Program under the provisions of Section 3-1202.G.(Case Number FLD2005-07063, 1200 N. Betty Lane). Dear Mr. Lafferty: The Planning staff has reviewed your application for Flexible Development approval as listed above for property located at 1200 N. Betty Lane. After a preliminary review of the submitted documents, staff has determined that the application is incomplete. Section 4- 202 of the Community Development Code states that if an application is deemed incomplete, the deficiencies of the application shall be specified by Staff. No further development review action shall be taken until the deficiencies are corrected and the application is deemed complete. In order to stay on the current schedule for review for sufficiency by the Development Review Committee (DRC) on August 4, 2005, the following information is required to be submitted by 12.00 Rm (Noon) on July 11, 2005 (should you be unable to meet this time frame, the next submittal deadline is July 29, 2005 [noon] to be reviewed for sufficiency by the DRC on September 1, 2005, if the application is deemed complete): The following items and/or information are required in order to make your application complete (submit one original and 14 copies): 1. Submit a Comprehensive Infill Redevelopment Flexible Development Application. The application form that you submitted is not for Comprehensive Infill. 2. On the application form, state what the request is specifically, referencing what code(s) are being requested for deviation, including parking requirements. FRANK I l It BAHI ). 1 A) i H: RU.i. Ic,x s, vicia-M,%1'o1:. IOM', I)URA%, (" ,WNCIIA1i:."•IMT IIUY1 IIAd?iiltHV_ t;nrn?:u.;ar uua; 0 CAM 1-N A- Plr'l tt:tirti, (:i)[ 1Nt HAII?. BFIi "EJ)i'n1. riA!) A!'1'noi1 , i ivi. Al i Tk i:.: ?%n,," r July 6, 2005 Lafferty- Page 2 3. The site plan does not show setback distances by dimensional arrows (in linear feet) from property lines to pavement and building. 4. Address the stormwater application submittal requirements. 5. Adequate site data table needs to be provided on the site plan, stating all code requirements, what exists, and what is proposed. Please note that this letter addresses completeness items only. Sufficiency will be determined upon receipt of a complete and correct application form. If you have any questions, please do not hesitate to call me at 727-562-4836. You can access zoning information for parcels within the City through our website: www.myclearwater.com. Sincerely, Michael H. Reynolds, AICP Planner III S: (Planning Depnrtmen6C D BIFLEX (FLD)IIncompleteWetty N. 1100 - Homeless Emergency Project - MHRIBetty N. 1200 Incomplete Letter.doc 0 >' j lealvater Michael L. Delk, AICP r t. Planning Director i Tel.: (727) 562-4561 PLANNING DEPARTMENT michael.delk@myclearwater.com // 2 v N, B??Ty G?l.uE 16. lvle"Oov 100 South Myrtle Ave. W .?• FT Clearwater, FL 33756 !/ 1 J Q3 see ??' tE?1a?h .?tle;?.. - TERRANCE MCABEE - Mhe ^ Director of Marketing f - HELPING PEOPLE FIELP THEMSELVES OFFICE (727) 442-9041 x 114 f ._._ FAX (727) 446-1516 CELL (727) 631-2196 EMAIL tmcabee@ethep.org - - -? _ ?08Ut`?G>71 i1i ?#/ dSB4 ? I'?.l ??'?5? ? ? ?. ?. u CDB Meeting Date: Case Number: Agenda Item: Applicant: Representative: Address: September 20, 2005 FLD2005-07063 F14 Homeless Emergency Project, Inc. Stephen B. Lafferty, 1200 North Betty Lane CITY OF CLEARWATER PLANNING DEPARTMENT STAFF REPORT GENERAL INFORMATION: 0 4rl REQUEST: Flexible Development application to permit the redevelopment and expansion of an existing residential shelter (including the expansion of the kitchen and dining area), in the Commercial District, to maintain the existing front, side and rear setbacks with the exception of a front (south) setback of 4 feet (to dumpster enclosure), and to permit off site parking, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G. EXISTING ZONING/LAND USE: C, Commercial District; CG, Commercial General Category PROPERTY SIZE: 0.43 acres PROPERTY USE: Current Use: Residential Shelter Proposed Use: Residential Shelter ADJACENT ZONING/LAND USES: North: Commercial District; Thrift Store West: Commercial District; Retail, storage East: Commercial District and Low Medium Density Residential District; Stevenson Creek, Single-family residential South: Commercial District; Church CHARACTER OF THE IMMEDIATE VICINITY: Single-family dwellings are to the east, with limited commercial uses on the east and west sides of North Betty Lane south of Stevenson Creek. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 1 • • ANALYSIS: Site Location and Existing Conditions: The 0.43-acre overall site is located on the northwest side of the intersection of North Betty Lane and Otis C. Greene Street. On site, there is an existing 8,750 square foot emergency shelter with 18 dwelling units. There is 2,020 square feet of kitchen and dining area. Proposal: What is proposed is an expansion of the kitchen and dining area to 4,003 square feet, new roofing, painting the building's exterior, landscaping, and re-allocation/designation of some parking spaces. Existing front, side, and rear setbacks will be maintained, with the exception of a front (south) setback to a dumpster enclosure. Off-site parking will be provided. Code Enforcement Analysis: There are no outstanding enforcement issues associated with this site. C'nMPI.IANCE WITH,STANDARDq AND CRITFRIA? (Certinns 2._7(11.1 and 7._7(ldl• STANDARD PROPOSED CONSISTENT INCONSISTENT MAXIMUM FLOOR N/A X AREA RATIO (FAR) 0.55 /A IMPERVIOUS 0.79 X SURFACE RATIO ISR 0.95 LOT AREA 0.43 acres; 18,730 square feet X minimum /A) LOT WIDTH 125 feet X minimum /A) FRONT SETBACK four feet to dumpster enclosure X* 25 feet /A four feet to building REAR SETBACK (20 0.6 feet to building X* feet) (N/A) SIDE SETBACK (10 West: 0.6 feet to building X* feet) (N/A) East: 5.3 feet to building HEIGHT (25' 18 feet X maximum /A PARKING (N/A) 2 spaces X *See Analysis. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 2 • • COMPLIANCE WITH COMPREHENSIVE INFILL CRITERIA (Section 2-704 C): Consistent Inconsistent 1. The development or redevelopment of the parcel proposed for X development is otherwise impractical without deviations from the use, intensity and development standards. 2. The development of the parcel proposed for development as a X Comprehensive Infill Redevelopment Project will not reduce the fair market value of abutting properties. 3. The uses within the Comprehensive Infill Redevelopment Project are X otherwise permitted in the City of Clearwater. 4. The use or mix of uses within the Comprehensive Infill X Redevelopment Project is compatible with adjacent land uses. 5. Suitable sites for development or redevelopment of the uses of mix of X uses within the Comprehensive Infill Redevelopment Project are not otherwise available in the City of Clearwater. 6. The development of the parcel proposed for development, as a X Comprehensive Infill Redevelopment Project will upgrade the immediate vicinity of the parcel proposed for development. 7. The design of the proposed Comprehensive Infill Redevelopment X Project creates a form and function that enhances the community character of the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. 8. Flexibility in regard to lot width, required setbacks, height and off- X street parking are justified by the benefits to community character and the immediate vicinity of the parcel proposed for development and the City of Clearwater as a whole. 9. Adequate off-street parking in the immediate vicinity according to the X shared parking formula in Division 14 of Article 3 will be available to avoid on-street parking in the immediate vicinity of the parcel proposed for development. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 3 • COMPLIANCE WITH GENERAL STANDARDS (Section 3-913): Consistent Inconsistent 1. Development of the land will be in harmony with the scale, bulk, X coverage, density and character of adjacent properties. 2. Development will not hinder or discourage development and use of X adjacent land and buildings or significantly impair the value thereof. 3. Development will not adversely affect the health or safety of persons X residing or working in the neighborhood. 4. Development is designed to minimize traffic congestion. X 5. Development is consistent with the community character of the X immediate vicinity. 6. Design of the proposed development minimizes adverse effects, X including visual, acoustic and olfactory and hours of operation impacts on adjacent properties. SUMMARY AND RECOMMENDATION: The Development Review Committee reviewed the application and supporting materials on August 4, 2005. The Planning Department recommends APPROVAL of the Flexible Development application to permit the redevelopment and expansion of an existing residential shelter (including the expansion of the kitchen and dining area), in the Commercial District, to maintain the existing front, side and rear setbacks with the exception of a front (south) setback of 4 feet (to dumpster enclosure), and to permit off site parking, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G. for the site at 1200 North Betty Lane, based upon the recommended findings of fact, conclusions of law and conditions of approval as follows: Recommended Findings of Fact: 1. Subject property is 18,730 square feet (0.43 acres), approximately 125 feet wide; 2. The site is within the Commercial (C) District and the Commercial General (CG) future land use plan classification; 3. Applicant seeks to redevelop and expand an existing residential shelter, including the expansion of the kitchen and dining area, maintaining the existing front, side, and rear setbacks with the exception of the front (south) setback of four feet (to dumpster enclosure) and to permit off-site parking as a Comprehensive Infill Project under the provisions of Section 2- 704.C and as a Comprehensive Landscape Program, under the provisions of Section 3- 1202.G.; Other improvements include the provision of a loading space and handicap parking space at the front of the building, landscaping, new roofing, exterior painting, and bicycle parking; and 4. No other changes are proposed for the site or building. Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 4 • • Recommended Conclusions of Law: 1. Staff finds the proposal compliant with the General Purposes of the Code per Sections 1- 103.A, B.2, E.9 and E.12; 2. Staff finds the proposal compliant with the Flexible Development criteria per Section 2-704.C 3. Staff further finds the proposal compliant with the Flexible Development criteria as a Comprehensive Infill Redevelopment Project per Section 2-704.C and General Applicability Standards per Section 3-913; and 4. Staff recommends Board approval of FLD2005-05038 based on the recommended findings of fact and conditions as stated. Recommended Conditions of Approval: 1. That all signage meet Code, including the removal/redesign of any existing nonconforming signs, through building permits prior to the issuance of a certificate of occupancy for the applicable site; 2. All Fire Department comments are to be met prior to any building permit issuance; 3. That a Right-of-Way utilization permit be obtained prior to building permit issuance; 4. That prior to building permit issuance, the site plan be revised, to the satisfaction of City staff, to show 23 feet in length parallel parking spaces; and 5. That the applicant make payment in lieu fir stormwater attenuation prior to building permit issuance. Prepared by: Planning Department Staff:/ !??` c??'LJ Michael H. Reynolds, AICP, Planner III ATTACHMENTS: Aerial Photograph of Site and Vicinity Location Map Future Land Use Map Zoning Atlas Map Application S:IPlanning DepartmentlC D BIFLEX (FLD)IPending cases)Up for the next CDBIBetty N. 1200 - Homeless Emergency Project (C) - 9-20-05 CDB - MfIMBetty N 1200 Staff Report.doc Staff Report - Community Development Board - September 20, 2005 - Case FLD2005-07063 - Page 5 u • qq SPRING U DR 3 5 g A _ ? TKV" tl ? W vLV7A vur JOEL u CALUMET N?s eem.ev IV) ?kOKOMIS rc 24 4n y V oTrEN ST GFWEN EA LEBENI ] CAROLYN ~ ?? RWUOIS $ NEAVEN CAIiOLYNN 9 . SANDY U SENT LA SANDY ?rn 0 3SS ?QI O ?a q(F ?.?SANDY (A m PLEASANT MARY L ROSEMONT OR a ? _ ?°d a z PRO JECT ST Y _ FAIRNON7 pZ tD CLARE S TE NPfEBECI?TT I ou « ?Q<O< y ¢ ? R INE ST ? Gi?W OR GnAtx ST ? 1; Wfl go o DO o ; st j 0 0 Y ST ?g RUSSELL S7 OVERIEA ST (? (?`?'? a ENE 1? ? <) 3 TANGERINE S< `J -ROLL Sf 37 ( Q ENGMMI Z p Sf ENGNAN Sf F06BROOK OR LASALLE ST ¢ MMIRAL CLARK ST { ,gz yT O; PN.N SLUFF Sr 2? 6?* N "B'S"'S PALAI BLUFF By g W?QQ LEVE1a7 ST E ® CT ? S Sr WI BAR MIBISIX7$ Si s sW ? f3 S O Q G-J O ? Z ? ?? ?? d ? f SONN^R Sf FIT PALIETTO ST C.R. 'S48 ? ? ?oU ST ?? ? q NG70LSON Sf Nlk NICNOISON ? W_ :J Y ? ? ?9 EIAtNAIOD ST ST ? a ED- 0 0 (aa O ICE sr I EtDPolW a 1 a l Q F ? o `_J ? LEE sr NAf\.E ?, sT PLAZA aa AN7 PoDGEWppD S7 a < < OaQa?? DA ? T A JACKSON RD FOREST RD a HART > S! PINEWOOD N s 3 ?$?? 8 CRESMEW Sr ST SR, 590 ? ?a flQ ? a? El I E S7?/,.jj? ?qa+w? ???aas < a ? L.....-J ?? LAU A ?I = r-1 ? R si nE. u p LAURA T? El E-1 ? o a ?? ?Qo El g ? ? Q F] FP n CLEVELAND I F_ Location Map Owner. Homeless Emergency Project, Inc. Case: FLD2005-07063 Site: 1200 N Betty Lane Property Size(Acres): 0.43 acres PIN: 10/29/15/26550/003/0070 Atlas Page: 2698 • • 0S/j? // r---- I ; L 409 k 1 i '+ _ i I ! ? I 1 1 I I 1 1 I I I 1 I I 11 I I I Y V 14 ? ?? _ i ? ," I ---I -'L-i --- i I 1 1 - I 1315 I I I `? 1311 L ------I I I I ; I 1 `? ?? 1301 1250 L1 1 I r-1 I 1 I ; I OlVIR I I I 1 ! ,o1N la ; I 1 Imdl ??ur--_ i I 1215 N N OB I r 1 1223 ---_ 1222 1221 I 1 z I 1 / I 1221 1217 i I , 1218 1216 1 i, J , __I `?? 1213 x1214 1215 --,1214 209 1 ?. / }209 1 4214-- --- -1 1 1 1 1 _1 1 _1 1 T1 r 1207 10 1205 % i r I, 1 r T 1205 j 1 ? r ;; I f 1 1 1 ?? ?? 120 i 1201 ?__ N 4-___t Sr 1 1119 LS ?-1' 1016 1128 1 1117 , 101 1127 ; - 1125 , 725-- i L ' , 1 1 ; 1126 - 1 r 1121 -- ]23 1 1124 1 1 --- 1 1 1122 11t?'1 -1-.1012 1011-1 , I 1 l 1 1 ? - 1 -J 1 1117 L 1117 1 __ ---- 0 1113 17"4 1 2 1 1115 1116 1113 r \.-? 101 1Q08"\ 1109 1 1 } 11110 1 1109 i 1 1148 \ \1008 1105 101 i _; r ?ao6 1101-- ?- 11 1120 - 1 ------ 1101 11100 1 _J 1 i L " F --1024 r I 1 I -- -J j --1022 •- -- - I 1015 1 L 0 r 7020 1021 : ` --1 ' i --? I 1 Lim I?10i6 1 1009 1 -004 007 1 --1101 1007 F-1 1002 Zoning Map Owner. Homeless Emergency Project, Inc. Case: FLD2005-07063 Property Site: 1200 N Betty Lane 0.43 acres Size(Acres): 10/29/15/26550/003/0070 PIN: Atlas Page: 269B u r---- 1 ? ic [1411 r--o? 1 °.? W ^ar1 a N I N I_ --? - -? i OVERLEA ST I I I I I I I ?n 14 =_ 1 11--? `? \\ 1315 , I I1 1 `\ 1311 1 -_J-_-' i'At1ta hed ; _ ; `\ ••,? W m 1301 1250 ?;d?ve >as1a I I ps---- mo , ' -_-' EN GMAN ST ? 1215 ? 11223 T ? R < Z gftidentl 1 , `• 1221 11 11221 I e , I I J , 1217 14D S a r J? p I 1213 r1'f?4 1215 1 _ _ _ 1214 11L _ ?? 11209 i 131 1209 1 _ y ' ' i etach I 4 d ---,9- '"--i ? ,? Vacant 7 4 a ntia 1205 2t7r , I r l I W d ?? 1 ; 1 j 11 1 ---' 1205 1---J , ? 1 ^° 1t20 dentia ' 1 1201 w . -- r - 1129 OT/S C. GREEN DR 111 -i' 1018 1 W r 1117 L' 1014 1127 --? I ` i -i 1 1125 1 .1. m f775-----l 1128 L_I- 1 `-- ?., J23 I N 1124 11?j"'1 1121 , .. 2f I ' ?--- fi 1173 1 3 --1_ _' r_ -j012 10f f I J 1 I 1117 rl 11 16 Ll-1 1117 1 --- - 1_- 1 L- - 1113 17J'A4 11112 1115 116 PI ce of 1113 1010 b 19W\ 1109 ,, Z \ \ 1 0 r \\ ' 1109 4 ,, 68 11 -1 11 orn ip m , , c e w , ,10}jwellings ? "°06 0 ,toy 1--- ? rLfl01 -I 1 , 100 1101-- o `- 11J)2 , , 1 1 I ' 1120 t• ? 7% ------ 1101 1 1 1 100 1 1 1 L.; r--1 1 _J a _ J I 1 _ 1en4 , ' , i 1 i -_ CEDAR ST _J 1 r---, 1022 1015 1 __J ----% ^ ?- l -1 020 ,__ 10.11 -.V 7020 1 I I 1 1 1 I-1? x'10 8 1 1009 `-' 1 -? 007 --1 1 --I 101 lets--+ r--apt 1007 F-1 1002 Existing Land Use Map Owner. Homeless Emergency Project, Inc. Case: FLD2005-07063 Site: 1200 N Betty Lane Property 0.43 acres Size(Acres) : 10/29/15/26550/003/0070 PIN: Atlas Page: 269B 0 • R/OS r---- ! I 141 1 , 1 1409 .°. L ?' I 1 1-? I t- t L t ? L r- --? - s OVERLEA ST IV I i I ( I 1 I 1 4Y \. ..1 ??? C F_ I l- ? ??/?,\ t-i?j \\ .\ 13 f5 I , ? ? IIr?V \ 1311 I \ I I L-- -- . \ W L------t _ I i \\ ..ice M i 1301 I ; RIOS 1250 1136 EN GMAN ST 1215 ? 1221 .N.. I ; ; 11223 r- 11. t f j < Z r----, % ?j -1 --' _I 1217 t--' , ' 1218 1218 1 t-----1 - ---- - -- 12LL---- 1213 I 12 t 1215 1214 1 109 C f 1209 1 y -- -- L-- ??2 RU I ---- 12ul-I I j 1207 1205 I t 4 f 1205 t 1 l I i I t 1 I ? ?`1 % ^\. fivs 1201 W 1- -- ' 120 ---, J \ I 1129 Z OTIS C. GREEN DR L,S 1018 I ot -- ; 7zf j 1 L r 1 1125 9 2tF .7 126--- t t 1 ? 104 ( 1128 -- l t_ r ti 1 1 j23 1 1124 11t? 1 -- p 1121 1 R W 1I --- i - 112a i w r- _=012 101'( - Z 1117 1117 t 1_-J ---- 0 1113 111 1115 1118 1113 .O 1 1109 r \?? ,01 t 1 INS F", 199.90 ;;11 RU j t4 11LJ 1105 ,008 p t 110;--- 1120 i i rj (----- 1101 1! I ,_J L __j ~; r A ' I , -102 1 I r-i? r 1 CEDAR ST i '- --I ; t j ---t I 1(? _ kn -_? --? j 10151 L- 1 ' -`_w0 7020 02i? -N I 1 t ___l I - ?1 1 t I ; , I_i? 8 1009 `-t S _1004 007 ---110 W-3- r--109 1007 F -I 1002 Future Land Use Map Owner: I Homeless Emergency Project, Inc. Case: FLD2005-07063 Property Site: 1200 N Betty Lane 0.43 acres Size(Acres): 10/29/15/26550/003/0070 PIN: Atlas Page: 269B •?',j,:,5sc?.??. _ ."nos ?,,t? i - "y :.....? View to the north, along N. Betty Lane w 1200 North Betty Lane FLD2005-07063 Looking northeast toward subject property. Looking southwest at property Looking northwest toward subject property. Owner. I Homeless Emergency Project, Inc. ? Case: FLD2005-07063 Site: 1200 N Betty Lane Property Size(Acres): 0.43 acres 10/29/15/26550/003/0070 I i PIN: r Atlas Page: 269B I'--? o1vv J --) ' 11 U (69 - I A N ? k I ?• i I a I TFFT TT' ,Iml VVV 14 13 n n n ,. « n LI Clarwater k!' «Y t a ] n li $" L" , i ms U n • w srREET PREPARED BY PUBLIC WORKS ADMINISTRATION " « tL • o a° ENGINEERING/GIS 100 S. Myrtle Ave., Clearwater, FL 33756 /e Ph.: (727)562-4750, Fax: (727)5264755 A ° $ , Al www.MyClearwater.com u 1 ' z ! n r? r n nr " s E otow- ' ,• n 0 • , ' PARKt1'000: °TREEf R,oac kv-fbndam 1.d w by ele C,ry d Cnan,em, . •-•? pl " _ Aubac Wales AdmfiYSfreO'aVEngirreedllg. andmusr De eccgfed I b ' - and l6Sdby lReleCp'erA wiN dm mMersMndarg 9.1 Nedala recakeC wes tneadedfor/ha dde ?. P I 6 , ! " ! Y •] i ` -kpv T ,r ] 1 . • aYresiruarae adnaaly. Aa ud the of ear largPWA'E T? • ? • ?'- " me.mnonana M, egaes.5ed or tmyred.-nagIft eaunry, GORPrderess. taaadY e ? _ .- orRnanaryd?N 1PWAarry j 6t asamneessW fiaDaoy W ?oeYer -W 9 dle usem nn> e ? • t ? wWD00SWE STREET H wd bE 1E.a ?, 1 r .v.r ..J 1 r E ,? i; uWa J ?Y,/ mo roo D Or• r ? ? En <c «. ? 8 ? ? F S ' "'? a . , A" " RESOEMMLI]ISTRIOTs IDR lowO Ny RmH OV/R + 1. M? '• w WODME STREET LtAOR Low MedemO avIWO- L-W r• 'T NOR mde "pe"R?mIEnIW t • a Y r? ' H10 Dm" Rmre,nvl '. L T ., 5 . . ]" a r F Nr LbOBp11 RPe] ? n c cRncOD-fcYRrIWI RH,OI'k1pOvN00d0onwrvalun wwoo Surd Esinm Ndprnomaod COneennpn ,f 4 , ' „ ? OWdaY tl91W ?? .3 • ?• ?'? y 1t ' +r ' a+] 5 n ?• } F ,r a , r ?! COMMERDUL DISTWGTS SPECIAL USE oSTRCTS ! dR 0-dlb IRT.hdu9naL iMVwrrtn aM T.cnndaSy A ., n T . iawkm I. om ^nuu,w ' +rr. STREET C. COmrertltl OSA.Ope Spam R,RMliOna D - DOmOewn P. R-1Lm W.a 4 i . b l City Owned Property TZ, 5L It ? C. Agreement to Annex RW 1]50 , aP' •I n ? Eaw.. n ! l r .? ! O D Annexation o Deannexation i $ * Correction c Rezoning ® STREET ns 1 n ", r•,:a , _ Czsl= SUB NUMBER "'• om JJ (' • Refer to Plot) n D! ' E E •'.., roy d ?, " ra D ' g a O BLOCK NUMBER Wna I Iw, r>s ! A ? " ? , ] SUB PARCEL NUMBER I [rmr . _ r J-P lnr? E ~• 'r t r 'o'q wooosoN x 1ANE ?r o „DMlnu • s?NZ PARCEL NUM n nu x" F i1° ,» r ° a ! r• LAND HOOK (COMMON OwNEWSHIP)l c u E e P n ",rm E ,„, 1 ? ; ' ,! r ] ,? I "' '? n !-"• PLATTED SUBDIVISION BOUNDARY .m] a w a. n a i s ? ? a •.. t 9 I w ," a ?,. Q COUNTY HIGHWAY "ISM STREET j ] • . « n.d M U STATE HIGHWAY ! '" ' 4 r '°& y r'°°' L • ! t? J Nor .• i ] ,]ma a A rr « n } r • ( ? ," m ., is U.S. HIGHWAY I 9, Outside City of Clearwater g w,w J , PALMETTO _- _____-- --- ??...• ... w.•wr BTREE .?. S « S ! n e " Sep 03, 2004 NE 114 o110.29-15 • a i 8 ? 26913 of ( Map Request Planner Name: Mike Reynolds Case Number: FLD2005-07063 Date Requested: August 31, 2005 Date Requested for: September 6, 2005 Maps Needed ® Aerial Photograph ? Proposed Annexation ® Existing Surrounding Uses Basemap ® Location Map ® Zoning/Flexible Development Map ? 2" x 2" Location Map for Newspaper ® Future Land Use Required Documents ® Legal Description ® Survey ® Map with Proposed Site Highlighted Maps Request Owner: Homeless Emergency Project, Inc. Case: FLD2005-07063 Site: 1200 N Betty Lane Property Size ( Acres) : 0.43 acres PIN: 10/29/15/26550/003/0070 Atlas Page: 2698 / Community Response Team Y Planning Dept. Cases _ DRC Case No.VLbaC05 _U_101 .%` Meeting Date: Location: lam be,4L4 La.- u Current Use: 1 Li i Fa C?Ltkis ? Active Code Enforcement Case no yes: ? Address number (yes) n (vacant land) ? Landscaping (yes) 6d ? Overgrown (yes) ? Debris (yes) (no ? Inoperative vehicle(s) (yes) (a ? Building(s) (good) ( air (poor) (vacant land) ? Fencing' on ) (good) (dilapidated) (broken and/or missing pieces) ? Paint g o) (fair) (poor) (garish) ? Grass Parking (yes) 0) ? Residential Parking Violations (yes) (?jo ? Signage (none) 0) (not ok) (billboard) ? Parking (n/a) (striped) (handicapped) (needs repaving) ? Dumpster (enclosed) of enclose ? Outdoor storage (yes) Comments/Status Report (attach any pertinent documents): Date: a Q6Reviewed by: QUO' Vic' Telephone: Z4 1) Revised 031-29-0f; 02-04-03 Case Number: FLD2005-07063 -- 1200 N BETTY LN f C Owner(s): Homeless Emergency Project t-'_ 1120 N Betty Ln G Clearwater, F133755 d./ TELEPHONE: No Phone, FAX: No Fax, E-MAIL: No Email -? Location: 0.43 acres located on the northwest side of the intersection of Betty Lane and Otis C. Greene Street. Atlas Page: 269B Zoning District: C, Commercial Request: Application for Flexible Development approval to permit a residential shelter as a Comprehensive Infrll Redevelopment Project, under the provisions of Section 2-704.C. and as part of a Comprehensive Landscape Program under the provisions of Section 3-1202.G. Proposed Use: Assisted living facilities Neighborhood Clearwater Neighborhoods Coalition Association(s): Clearwater, FI 33761 2544 Frisco Drive TELEPHONE: 727-725-3345, FAX: No Fax, E-MAIL: Djw@gte.net Neighborhood North Greenwood Association, Inc. Association(s): Clearwater, 17133755 1201 Douglas Road TELEPHONE: 560-4382, FAX: No Fax, E-MAIL: WADENWADE@AOL.COM Neighborhood Country Club Estates Neighborhood A Association(s): Clearwater, Fl 33755 800 N Betty Lane TELEPHONE: 298-0096, FAX: No Fax, E-MAIL: mark.woolridge@palmettogba.com Presenter: Mike Reynolds, Planner III Attendees Included: Neil Thompson, Mike Reynolds, Scott Rice, Tom Glenn, Anne Blackburn, Rick Albee The DRC reviewed this application with the following comments: General Engineering: 1 . 1. Prior to Community Development Board, show on the plan the location of the grease interceptor if required for this use. General Note: DRC review is a prerequisite for Building Permit Review, additional comments may be forthcoming upon submittal of a Building Permit Application. Environmental: I . See stormwater conditions Fire: Development Review Agenda - Thursday, August 4, 2005 - Page 41 r• Notes: 1. ***PLEASE NOTE*** REVIEW AND APPROVAL BY THE AUTHORITY HAVING JURISDICTION SHALL NOT RELEIVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE 2004 EDITION. This DRC reveiw by Fire is not an approval or review of any construction plans or documents other than site work. Please acknowledge PRIOR TO CDB. 2. The entire property, new dining structure and 18 dwelling units, must be protected by a fire sprinkler system as per NFPA-13. Please acknowledge PRIOR TO CDB. 3 . Provide and show on the site plan a hydrant within 300 ft of the building. Please acknowledge PRIOR TO CDB. 4. Show on the site plan the FDC {Fire Department Connection) located at least 15 feet off the building and within 40 feet of a fire hydrant PRIOR TO CDB. 5 . Where underground water mains and hydrants are to be installed, they shall be installed, completed, and in service prior to construction as per NFPA-241. Please acknowledge PRIOR TO CDB. 6. Clearances of 7 1/2 feet in front of and to the sides of the fire hydrant, with a 4 foot clearance to the rear of the hydrant, are required to maintained as per NFPA-1, please acknowledge PRIOR TO CDB. 7. Fire Department Connections shall be identified by a sign that states "No Parking, Fire Department Connection" and shall be designed in accordance with Florida Department of Transportation standards for information signage and be maintained with a clearance of 7 1/2 feet in front of and to the sides of applliance, as per Florida Fire Prevention Code 2004 edition. Please acknowledg PRIOR TO CDB. Harbor Master: No Comments Legal: No Comments Land Resources: No Comments Landscaping: No Comments Parks and Recreation: I . No issues - homeless shelter replacing existing dining hall with permanent structure Stormwater: Solid Waste: Project is considered redevelopment by City of Clearwater Stormwater Criteria and therefore, redeveloped area must meet current criteria for water quality and attenuation. This requirement shall be addressed prior to CDB. That dumpster enclousure(s) needs to be constructed to City specifications. As a 3yd Dumpster exists on property now. The Black Barrels shown on drawing are not asscociated with this address. Traffic Engineering: I , Proposed parking spaces backing into right-of-way is not allowed under Community Development Code Section 3-1402 C.. 2. Driveway does not meet minimum spacing requirements of 125' from driveway edge of curb to intersection edge of curb. All of the above to be addressed prior to CDB. Planning: 1 . 1. Provide plan set index to plan sheets. 2. On the application form, state what the request is specifically, referencing what code(s) are being requested for deviation, including parking requirements. 3. Improve the legibility of the detail shown on the site plan. 4. Provide 8 1/2 by I V color landscape plan. 5. Provide greater detail to justify the request, including back out parking. Other: No Comments Development Review Agenda - Thursday, August 4, 2005 - Page 42 Reynolds, Mike From: Rice, Scott Sent: Wednesday, August 17, 2005 3:01 PM To: Reynolds, Mike Cc: Elbo, Bennett; Kinney, Jason Subject: FLD2005-07063 - 1220 N. Betty Lane Mike, Engineering has completed review of the subject resubmittal and updated Permit Plan. Approval conditions: Prior to building permit, a right-of-way utilization permit shall be obtained. Prior to building permit, parallel parking spaces shall be revised to be 23-feet long. Prior to building permit, applicant shall make payment in lieu for stormwater attenuation. D. Scott Rice Land DeveL Engr. Manager 727-562-4781 scott.rice@MyClearwater.com Revised 09/19/2005 CONSENT AGENDA COMMUNITY DEVELOPMENT BOARD Date: Tuesday, September 20, 2005 Time: 10:00 a.m. Place: 112 South Osceola Street, 3rd Floor Clearwater, Florida, 33756 (City Hall Council Chambers) Welcome the City of Clearwater Community Development Board (CDB) meeting. The City strongly supports and fully complies with the Americans with Disabilities Act (ADA). Please advise us at least 72 hours prior to the meeting if you require special accommodations. Assisted listening devices are available. An oath will be administered swearing in all participants in public hearing cases. If you wish to speak please wait to be recognized, then state and spell your name and provide your address. Persons speaking before the CDB shall be limited to three minutes unless an individual is representing a group in which case the Chairperson may authorize a reasonable amount of time up to 10 minutes. Kindly refrain from conducting private conversations, using beepers, cellular telephones, etc. that are distracting during the meeting. Florida Statue 286.0105 states: Any person appealing a decision of this Board must have a record of the proceedings to support such appeal. Community Development Code Section 4- 206 requires that any person seeking to: personally testify, present evidence, argument and witness, cross-examine witnesses, appeal the decision and speak on reconsideration requests should request party status during the case discussion. Party status entitles parties to: personally testify, present evidence, argument and witnesses, cross-examine witnesses, appeal the decision and speak on reconsideration requests. If you have questions or concerns about a case, please contact the staff presenter from the Planning Department listed at the end of each agenda item at 727-562-4567. Make Us Your Favorite! www.myclearwater.com/gov/depts/planning Community Development Board Consent Agenda - September 20, 2005 - Page 1 of 14 A. CALL TO ORDER, INVekTION, PLEDGE OF ALLEGIANCE B. ROLL CALL: Chair Gildersleeve, Vice Chair Plisko, Members Coates, Johnson, Milam, Fritsch, Tallman, Alternate Member (Dennehy), City Staff C. APPROVAL OF MINUTES OF PREVIOUS MEETING: August 16, 2005 D. DIRECTOR'S ITEM (Item 1): 1. Expert Witness List Addition - Franklin Cky Ready, Planner H E. REQUEST FOR CONTINUANCE (to a date uncertain) (Item 1): 1. Case: DVA2004-00002A - 229 and 301 South Gulfview Boulevard and 230, 300 and 304 Coronado Drive Level Three Application Owner/Applicant: Crystal Beach Capital, LLC Representative: Stepehn J. Szabo, III, Foley & Lardner, LLP (100 North Tampa Street, Suite 2700, Tampa, FL 33601; phone: 813-229-2300; fax: 813-2214210; email: sszabo a)foley.com). Location: 1.63 acres located between South Gulfview Boulevard and Coronado Drive at Third Street. Atlas Page: 276A. Zoning District: Tourist (T). Request: Review of, and recommendation to the City Council, of an amended Development Agreement between Crystal Beach Capital, LLC (the property owner) and the City of Clearwater (previously approved DVA2004-00002 by City Council on December 2, 2004). Approved Use: Hotel of 250 rooms (153.37 rooms/acre on total site), 18 attached dwellings (11.04 units/acre on total site) and a maximum of 70,000 square feet (0.98 FAR on total site) of amenities accessory to the hotel, at a height of 150 feet (to roof deck). Neighborhood Association: Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767; phone: 727443-2168; email: papam=hy@aol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Diw(& e.net). Presenter: Gina L. Clayton, Assistant Planning Director F. CONSENT AGENDA (Items 1-16): 1. Case: FLD2005-05043 - 651 Bay Esplanade Level Two Application Owners: Ardent International, LLC and P. Vasiloudes Applicant: M3B Development, LLC. Representative: Robert Szasz (1860 North Fort Harrison Avenue, Clearwater, FL 33755; phone: 727-467-0730; fax: 727-467-0732; email: rbszasz@aol.com). Location: 0.491 acres located at the southeast corner of Bay Esplanade and Poinsettia Avenue. Atlas Page: 258A. lJ Zoning District: Tourist (T) District. Request: Flexible Development approval to permit 14 attached dwellings with an increase to building height from 35 feet to 59 feet (to roof deck) with an additional 3.5 feet for perimeter parapets (from roof deck) and reductions to the rear (south) setback from 20 feet to seven feet (to pool deck) and from 20 feet to 11 feet (to pool), as part of a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-803.C. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: djw(a?gte.net); Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767; phone: 727-443-2168; email: papamurphy@aol. com). Presenter: Robert G. Tefft, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 2 of 14 2. Case: 171,1)2005-050 1254 Grove Street IW. Level Two Application Owner/Applicant: Pia A. Bilotta & Lorri S. Ritter; LOPA, L Representative: Patricia A. Bilotta Location: 0.172 acres located at the northwest corner of Grove Street and South Betty Lane. Atlas Page: 287B. Zoning District: Medium High Density Residential (MHDR) District. Request: Flexible Development approval to permit three attached dwellings with a reduction to the front (south) setback from 25 feet to 23 feet (to pavement), a reduction to the front (east) setback from 25 feet to 14 feet (to building), a reduction to the side (north) setback from 10 feet to zero feet (to building) and a reduction to the required number of parking spaces from 1.5 spaces per dwelling unit G (5 spaces) to 1.33 spaces per dwelling units (4 spaces), as a Residential Infill Project, under the provisions of Section 2-404.F, and a reduction to the landscape buffer along the north side from 10 feet to zero feet, as part of a Comprehensive Landscape Program, under the provisions of Section 3- 1202.G. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Diw e.net). Presenter: Robert G. Tefft, Planner III. 3. Case: FLD2005-07064 - 621 Bay Esplanade Level Two Application Owner/Applicant: Coates 1, Inc. Representative: Keith Zayac; Keith Zayac and Associates (701 Enterprise Road, Suite 404 Safety Harbor, FL 34695; phone: 727-793-9888; fax: 727-793-9855; email: keith(a)keithzayac.com). Location: 0.37 acres located along the east side of Bay Esplanade and west of Cypress Avenue. Atlas Page: 258A. Zoning District: Tourist (T) District. Request: (1) Termination of Status of Nonconformity for density (18 existing overnight accommodation units to be converted to 13 attached dwelling units, where a maximum of 11 dwelling units would be permitted under current Code), under the provisions of Section 6-109; and (2) Flexible Development approval to permit 13 attached dwellings with an increase to building height from 35 feet to 53.25 feet (to roof deck) with an additional nine feet for perimeter parapets (from roof deck) and an additional 22 feet for architectural embellishments (from roof deck), a reduction to the rear (east) setback from 20 feet to 15 feet, as part of a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-803.C. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: papamurphyna aol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djw@gte.net). Presenter: Robert G. Tefft, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 3. of 14 4. Case: FLD2005-07065 -Way Esplanade and 566 Bay Esplanade Level Two Application Owner/Applicant: Bay Esp anade Properties, LLC. Representative: Keith Zayac; Keith Zayac and Associates (701 Enterprise Road, Suite 404 Safety Harbor, FL 34695; phone: 727-793-9888; fax: 727-793-9855; email: keith@keithzayac.com). Location: 0.55 acres located at the northeast corner of Bay Esplanade and Cypress Avenue. Atlas Page: 258A Zoning District: Tourist (T) District. Request: (1) Termination of Status of Nonconformity for density (15 existing overnight accommodation units to be converted to 13 attached dwelling units, where a maximum of eight dwelling units would be permitted under current Code) at 64 Bay Esplanade, under the provisions of Section 6-109; and (2) Flexible Development approval to permit 21 attached dwellings within the Tourist (T) District with an increase to height from 35 feet to 52 feet (to roof deck) with an additional 11 feet for perimeter parapets (from roof deck) and an additional 19 feet for architectural embellishments (from roof deck), and a reduction to the front (east) setback from 15 feet to zero feet (to pavement) as part of a Comprehensive Infill Redevelopment Project under the provisions of Section 2-803.C. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: papamurphy@aol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: D,jw>e.net). Presenter: Robert G. Tefft, Planner III. 5. Case: FLD2005-06058 - 1242 Cleveland Street Level Two Application Owners: Raim Tzekas. Applicant/Representative: A Very Important Pet, Jaycee Roth (330 Duncan Loop Building 27, #207, Dunedin, FL 34698; phone: 727-459-4400; fax: none; email: jaycee5552002gyahoo.com). Location: 0.48 acres located at the northwest corner of the intersection of Cleveland Street and North Lincoln Avenue. Atlas Page: 287B. Zoning District: Downtown (D) District (East Gateway Subdistrict). Request: Flexible Development approval to allow pet grooming and outdoor dog training in conjunction with a pet supply store and to permit a six-foot tall fence located in front of the building (approximately five feet back from the North Lincoln Avenue frontage), as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-903.C. Proposed Use: Pet Grooming/Outdoor Training Facility. Neighborhood Associations: Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: diw@ tg e.net). Presenter: John Schodtler, Planner I. Community Development Board Consent Agenda - September 20, 2005 - Page 4 of 14 6. Case: FLD2005-06050DR2005-07023 - 691 South Gulfview B evard Level Two Application Owner: Seawake Motel, Ltd. Applicant: Enchantment, LLC. Representative: E. D. Armstrong 111, Esq., Johnson, Pope, Bokor, Ruppel & Burns, LLP (P.O. Box 1368, Clearwater, FL 33757; phone: 727-461-1818; fax: 727-441-8617; e-mail: eda@jpfirm.com). Location: 1.459 acres located on the south side of South Gulfview Boulevard, approximately 700 feet west of Gulf Boulevard. Atlas Page: 285A. Zoning Districts: Tourist (T) and Open Space/Recreation (OS/R) Districts. Request: (1) Termination of Status of Nonconformity for density (110 existing overnight accommodation units to be converted to 82 attached dwellings units, where a maximum of 40 dwelling units are permitted under current Code); (2) Flexible Development approval to permit 90 attached dwellings with reductions to the front (north) setback from 15 feet to seven feet (to entry sidewalk) and from 15 feet to zero feet (to trash staging area), reductions to the side (west) setback from 10 feet to three feet (to trash staging area), reductions to the rear (south) setback from 20 feet to 15.7 feet ( to sidewalk) and from 20 feet to 14 feet (to cantilevered balconies), an increase to building height from 35 feet to 150 feet (to roof deck), a deviation to allow a building within visibility triangles and a deviation to allow direct access to an arterial street, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-803.C; and (3) Transfer of Development IN Rights (TDR2005-07023) of three dwelling units from 125 Brightwater Drive, four dwelling units from 161 Brightwater Drive and one dwelling unit from 321 Coronado Drive, under the provisions of Section 4-1402. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Point 1 Beach House 16 (845 Bayway Blvd, Clearwater, Fl 33767; phone: 727-535-2424); Clearwater Point 3 Marina House 17 (868 Bayway Blvd #212, Clearwater, F1 33767); Clearwater Point 4 Island House 1(895 S Gulfview Blvd, Clearwater, Fl 33767; phone: 727-530-4517); Clearwater Point 5 Admiral House 19 (825 S Gulfview Blvd #104, Clearwater, F1 33767; phone: 727-447-0290); Clearwater Point 7 Inc, Yacht House (851 Bayway Blvd, Clearwater, Fl 33767; phone: 727-441-8212; e-mail: cpoint7Qknology.net); Clearwater Point 8 Shipmaster, Sail (800 S Gulfview Blvd, Clearwater, Fl 33767; phone: 727-442-0664; e-mail: clwpt864t`ampabay.rr.com); Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: papamurphyAaol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725- 3345; email: DjwA e.net). Presenter: Wayne M. Wells, AICP, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 5 of 14 7. Case: FLD2005-07072 - - 655 South Gulfview Boulevard Level Two Application Owner/Applicant: Clear er Grande Development, LLC Representative: Housh Ghovaee, Northside Engineering Services, Inc. (601 Cleveland Street, Suite 930, Clearwater, FL 33755; phone: 727-443-2869; fax: 727-446-8036; email: nestechQmindspring com). Location: 1.437 acres located on the south side of South Gulfview Boulevard approximately 1,200 feet west of Gulf Boulevard. Atlas Page: 285A. Zoning District: Tourist (T) District. Request: (1) Termination of Status of Nonconformity for density (91 existing overnight accommodation units to be converted to 68 attached dwellings units, where a maximum of 43 dwelling units permitted under current Code); and (2) Flexible Development approval to permit 68 attached dwellings with a reduction to the side (east) setback from 10 feet to 6.3 feet (to sidewalk), a reduction to the side (west) setback from 10 feet to 6.8 feet (to sidewalk), reductions to the rear (south) setback from 20 feet to 18 feet (to building), from 20 feet to 17.6 feet (to open stairs) and from 20 feet to 8.8 feet (to pool deck), an increase to the building height from 35 feet to 99.5 feet (to roof deck) with an additional 11.5 feet for perimeter parapets (from roof deck) and an additional 16.67 feet for architectural embellishments (from roof deck), a deviation to allow the building within U the sight visibility triangles and a deviation to allow direct access to an arterial street, as a l) Comprehensive Infill Redevelopment Project, under the provisions of Section 2-803.C. C Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Point 1 Beach House 16 (845 Bayway Blvd, Clearwater, Fl 33767; phone: 727-535-2424); Clearwater Point 3 Marina House 17 (868 Bayway Blvd #212, Clearwater, Fl 33767); Clearwater Point 4 Island House 1(895 S Gulfview Blvd, Clearwater, Fl 33767; phone: 727-530-4517); Clearwater Point 5 Admiral House 19 (825 S Gulfview Blvd #104, Clearwater, Fl 33767; phone: 727-447-0290); Clearwater Point 7 Inc, Yacht House (851 Bayway Blvd, Clearwater, Fl 33767; phone: 727-441-8212; e-mail: cpoint7Aknology.net); Clearwater Point 8 Shipmaster, Sail (800 S Gulfview Blvd, Clearwater, Fl 33767; phone: 727-442-0664; e-mail: clwpt8(a)tampabay.rr.com); Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: papam11Mhy(a,aol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725- 3345; email: Diw(a_),Qte.net). Presenter: Wayne M. Wells, AICP, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 6 of 14 8. Case: FLD2005-0706801, 411 and 421 South Gulfview Boule Level Two Application Owners: Canterbury erty Management, Inc., TLS Holding c., Canterbury Oaks, Inc. and Dorothy C. Boldog, Trustee for M & J Trust. Applicant: Canterbury Property Management, Inc. Representative: E. D. Armstrong III, Esq., Johnson, Pope, Bokor, Ruppel & Burns, LLP (P.O. Box 1368, Clearwater, FL 33757; phone: 727-461-1818; fax: 727-441-8617; e-mail: eda@jpfirm.com). Location: 1.994 acres located between South Gulfview Boulevard and Coronado Drive at the intersection with Fifth Street. Atlas Page: 276A. Zoning District: Tourist (T) District. Request: (1) Termination of Status of Nonconformity for density (127 existing overnight accommodation units to be converted to 95 attached dwellings units, where a maximum of 54 dwelling units are permitted under current Code); and (2) Flexible Development approval to permit 100 attached dwellings with reductions to the front (west along South Gulfview Boulevard) setback from 15 feet to 5.45 feet (to building), from 15 feet to zero feet (to decorative architectural pavement pedestrian plaza) and from 15 feet to zero feet (to dumpster staging area), a reduction to the front (north along Fifth Street) setback from 15 feet to 3.63 feet (to building), a reduction to the front (east along Coronado Drive) setback from 15 feet to zero feet (to pavement), a reduction to the rear (west) setback from 20 feet to 15 feet (to building) and an increase to building height from 35 feet to 100 feet (to roof deck) with an additional 8.5 feet for perimeter parapets (from roof deck) and an additional 21 feet for architectural embellishments (from roof deck), as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-803.C. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: papamurphy(a,aol.com); 440 West, Inc. Condominium (Fred White, 440 South Gulfview Boulevard, #203, Clearwater, FL 33767; phone: 727-461-2885; fax: 727-442-6628; email: et440@juno.com); Continental Towers (675 South Gulfview Boulevard, #1002, Clearwater, FL 33767; phone: 727-449-9189; email: fandjnassif da webtv.net); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djwkgte.net). Presenter: Wayne M. Wells, AICP, Planner III. 9. Case: FLD2005-07061 - 229 Coronado Drive Level Two Application Owner: Sunrise on the Beach, Inc. Applicant: Mark International, LLC Representative: Keith Zayac; Keith Zayac and Associates (701 Enterprise Road, Suite 404 Safety Harbor, FL 34695; phone: 727-793-9888; fax: 727-793-9855; email: keithQkeithzayac.com). Location: 0.454 acres located on the north side of Third Street between Coronado Drive and Hamden Drive. Atlas Page: 276A. Zoning District: Tourist (T) District. Request: (1) Termination of Status of Nonconformity for density (22 existing overnight accommodation units to be converted to 16 attached dwellings units, where a maximum of 13 dwelling units permitted under current Code), under the provisions of Section 6-109; and (2) Flexible Development approval to permit 16 attached dwellings with reductions to the minimum lot width from 100 feet to 90 feet along Coronado Drive and Hamden Drive, a reduction to the front (south) setback from 15 feet to zero feet (to trash staging area), a reduction to the side (north) setback from 10 feet to six feet (to sidewalk), an increase to building height from 35 feet to 53.5 feet (to midpoint of roof) and to allow the building within the sight visibility triangles, under the provisions of Section 2-803.B. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: pMamurphy(i?aol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djw@ e.net). Presenter: Wayne M. Wells, AICP, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 7 of 14 10. Case: LUZ2005-05009 32 S. Highland Avenue and a portion of?6 S. Highland Avenue Level Three Application Owner/Applicant: Aubrey and Caroline Wilkes. Representative: Denise Giarratano, Charles Rutenberg Realty. Location: 0.4121 acres on the west side of South Highland Avenue, beginning at 700 feet north of the intersection of Highland Avenue and Belleair Road. Atlas Page: 315A Request: (a) Future Land Use Plan amendment from the Residential Low (RL) Category to the Residential/Office General (R/OG) Category (1532 S. Highland Avenue and a portion of 1536 S. Highland Avenue); and f , 1 (b) Rezoning from the Low Medium Density Residential (LMDR) District to Office (O) District (1532 South Highland Avenue only). C Proposed Use: Offices. Type of Amendment: Small Scale. Neighborhood Association(s): Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djw@a Rte.net). Presenter: Michael H. Reynolds, AICP, Planner III. 11. Case: ANX2005-04015 - 2695 2nd Avenue S. Level Three Application Owner: Rottlund Homes. Representative: Robert Pergolizzi, 13825 ICOT Boulevard, Suite 605, Clearwater, FL 33760; phone: 727-524-1818; fax: 727-524-6090. Location: 4.86-acre property consisting of four parcels, located on the east side of Chautauqua Avenue, between 2nd Avenue S. and 3rd Avenue S. Atlas Page: 244A. Request: (a) Annexation of 4.86-acres of property and abutting 2nd Avenue S. and 3`d Avenue S. rights-of-way to the City of Clearwater; (b) Future Land Use Plan amendment from the Residential Suburban (RS) and Preservation (P) Categories (County) to the Residential Suburban (RS) and Preservation (P) Categories (City of Clearwater); and (c) Rezoning from the RR, Rural Residential District (County) to the Low Density Residential (LDR) and Preservation (P) Districts (City of Clearwater). Proposed Use: New Single-Family Dwellings. Neighborhood Association(s): Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: DjwgP_te.net). Presenter: Gina L. Clayton, Assistant Planning Director. 12. Case: ANX2005-06020 - 3137 San Jose Street Level Three Application Owner: Adam Saldana. Location: 0.22-acre property consisting of one parcel, located on the south side of San Jose Street, between Madera Avenue and McMullen Booth Road. Atlas Page: 283A. Request: (d) Annexation of 0.22-acres of property to the City of Clearwater; (e) Future Land Use Plan amendment from the Residential Urban (RU) Category (County) to the Residential Urban (RU)) Category (City of Clearwater); and (f) Rezoning from the R-3, Residential District (County) to the Low Medium Density Residential (LMDR) District (City of Clearwater). Proposed Use: Single-Family Dwelling. Neighborhood Association(s): Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: DiwQ te.net). Presenter: Cky Ready, Planner IJ. Community Development Board Consent Agenda - September 20, 2005 - Page 8 of 14 13. Case: ANX2005-0602' 1715 Keene Road Level Three Application Owner: City of Clear w. Location: 0.36-acres of property consisting of one parcel, located on the south side of Flagler Drive, between N. Keene Road and Hercules Avenue. Atlas Page: 262A. Request: (a) Annexation of 0.36-acres of property and abutting N. Keene right-of-way (0.06-acres) to the City of Clearwater; (b) Future Land Use Plan amendment from the Industrial Limited (IL) Category (County) to the v Industrial Limited (IL) Category (City of Clearwater); and (c) Rezoning from the M-l, Manufacturing and Industry District (County) to the Industrial, Research and Technology (IRT) District (City of Clearwater). Proposed Use: Existing Public Service Facility. Presenter: Cky Ready, Planner II. 14. Case: ANX2005-06023 - 1932 Summit Drive Level Three Application Owner: Corinne Davis. Representative: Judy Lehan, 204 S. Jupiter Avenue, Clearwater, FL 33755; phone: 727-423-5875. Location: 0.17-acres of property consisting of one parcel, located on the west side of Summit Drive, between W. Skyline Drive and Ridgemont Drive. Atlas Page: 254B. Request: (a) Annexation of 0.17-acres of property to the City of Clearwater; (b) Future Land Use Plan amendment from the Residential Low (RL) Category (County) to the Residential Low (RL) Category (City of Clearwater); and (c) Rezoning from the R-3, Residential District (County) to the Low Medium Density Residential (LMDR) District (City of Clearwater). Proposed Use: Single-Family Dwelling. Neighborhood Association(s): Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: G Diw(a) tg e.net). Presenter: Cky Ready, Planner 11. 15. Case: ANX2005-07024 - 2275 McMullen Booth Road Level Three Application Owner: Gus DiGiovanni, Renaissance Oaks, LLC. Representative: Ronald Letize, 1928 Valencia Way, Clearwater, FL 33764; phone: 727-433-1143; fax: 727-447-6811. Location: 20-acres of property consisting of one parcel, located on the west side of McMullen Booth Road, between Crest Drive and Marlo Boulevard. Atlas Page: 245A. Request: (a) Annexation of 20-acres of property to the City of Clearwater; (b) Future Land Use Plan amendment from the Residential Suburban (RS) Category (County) to the Residential Suburban (RS) Category (City of Clearwater); and (c) Rezoning from the R-1, Residential District (County) to the Low Density Residential (LDR) District (City of Clearwater). Proposed Use: Multi-Family Dwelling. Neighborhood Association(s): Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djw@ tg e.net), and Oakbrook Estates of Pinellas HOA (Kathy Rampolla, 3036 Oakbrook Circle, Clearwater, FL 33759; phone 727-712-1271; email: GRAMPOLLA@tampabay.rr.com). Presenter: Cky Ready, Planner II. Community Development Board Consent Agenda - September 20, 2005 - Page 9 of 14 IC: Case: FLD2005-07063 00 North Betty Lane Level Two Application Owner/Applicant: Hon ss Emergency Project, Inc. Representative: Lafferty Architecture Group, LLC/Stephen B. Lafferty, AIA (11414 Seminole Boulevard, Suite 5, Largo, Florida 33778) Location: 0:43acres located on the northwest side of the intersection of Betty lane and Otis C. Greene Street. Atlas Page: 269B. Zoning: C, Commercial District. Request: Flexible Development application to permit the redevelopment and expansion of an existing residential shelter (including the expansion of the kitchen and dining area), in the Commercial District, to maintain the existing front, side and rear setbacks with the exception of a front (south) setback of 4 feet (to dumpster enclosure), and to permit off site parking, as a Comprehensive Infill (v, Redevelopment Project, under the provisions of Section 2-704.C and as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G. Proposed Use: Residential shelter of 18 units. Neighborhood Associations: Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djw Q e.net). Presenter: Michael H. Reynolds, AICP, Planner III G. RECONSIDERED ITEM (Item 1): 1. Case: FLD2005-01004 - 1874 North Highland Avenue Level Two Application Requester: City of Clearwater. Request: Reconsideration of the attached sign approved through the Comprehensive Sign Program application contained within the Flexible Development Comprehensive Infill Redevelopment Project application that approved a problematic use for Amscot Financial in this location. Owner: Mexico Grande, Inc. Applicant: Amscot Financial. Representative: Todd Pressman (28870 US Highway 19 North, Clearwater, FL 33761; tel: 727-726- .,8683' fax: 727-669-8114; email: pressinc@aol.com). Location: 0.39-acres located on the west side of North Highland Avenue, approximately 250 feet south of Sunset Point Road. Al Atlas Page: 261 A. w n I Zoning District: Commercial (C) District. Proposed Use: Problematic Use (Amscot). Neighborhood Associations: Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 .,? , Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djw(a) e.net); Fountain Square Condo Association (1799 Highland Ave, # 147 Q, Clearwater, FL 33755; phone: 442-7335). Presenter: Robert G. Tefft, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 10 of 14 H. LEVEL TWO APPLOTIONS (Items 1- 4): Case: FLD2005-06056/PLT2005-00015 - 475 East Shore Drive Level Two Application Owner: Parkdale, LLC. Applicant: Belleair Harbor, LLC Representative: Bret Krasman, P.E.; Krasman and Associates (31564 US 19 North, Palm Harbor, FL 34684; phone: 727-787-4684; fax: 727-781-3345; email: Bret a,krasen rg com). Location: 0.19 acres located on the east side of East Shore Drive, approximately 300 feet south of the intersection of East Shore Drive and Baymont Street. Atlas Page: 267A. Zoning District: Tourist (T) District. Request: Flexible Development approval to permit attached dwellings with a reduction to the minimum lot area requirement from 10,000 square feet to 8,171 square feet, a reduction to the minimum lot width requirement from 100 feet to 60 feet, a reduction to the front (west) setback from 15 feet to zero feet (to pavement), a reduction to the side (north) setback from 10 feet to five feet (to building), a reduction to the side (south) setback from 10 feet to five feet (to building), a reduction to the rear (east) setback from 20 feet to zero feet (to pool deck) and from 20 feet to 10 feet (to pool), and to permit parking that is designed to back out into the public right-of- way, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-803.C. and Preliminary Plat approval for two lots. Proposed Use: Attached dwellings (two units). Neighborhood Associations: Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: papamurphy(a aol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Diw(a ge.net). Presenter: Michael H. Reynolds, AICP, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 11 of 14 2. Case: FLD2005-07070 -" Bayway Boulevard Level Two Application Owner/Applicant: Harbor5ide Condominiums, LLC Representative: Housh Ghovaee, Northside Engineering Services, Inc. (601 Cleveland Street, Suite 930, Clearwater, FL 33755; phone: 727-443-2869; fax: 727-446-8036; email: nestech@mindspring.com . Location: 0.35 acre located on the north side of Bayway Boulevard, approximately 300 feet west of Gulf Boulevard. Atlas Page: 285A. Zoning District: Tourist (T) District. Request: (1) Termination of Status of Nonconformity for density (16 existing attached dwelling units; 15 attached dwelling units proposed, where a maximum of 10 dwelling units permitted under current Code), under the provisions of Section 6-109; and (2) Flexible Development approval to permit 15 attached dwellings with reductions to the front (south) setback from 15 feet to 12.4 feet (to pavement) and from 15 feet to three feet (to trash staging area), a reduction to the side (east) setback from 10 feet to five feet (to pavement), reductions to the side (west) setback from 10 feet to 8.3 feet (to pavement) and from 10 feet to 4.3 feet (to sidewalk), reductions to the rear (north) setback from 20 feet to 18 feet (to building), from 20 feet to 10.8 feet (to pavement) and from 20 feet to 6.8 feet (to sidewalk) and an increase to building height from 35 feet to 87.25 feet (to roof deck) with an additional 8.67 feet for perimeter parapets (from roof deck), under the provisions of Section 2-803.B. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Point 1 Beach House 16 (845 Bayway Blvd, Clearwater, Fl 33767; phone: 727-535-2424); Clearwater Point 3 Marina House 17 (868 Bayway Blvd #212, Clearwater, Fl 33767); Clearwater Point 4 Island House 1(895 S Gulfview Blvd, Clearwater, Fl 33767; phone: 727-530-4517); Clearwater Point 5 Admiral House 19 (825 S Gulfview Blvd #104, Clearwater, Fl 33767; phone: 727-447-0290); Clearwater Point 7 Inc, Yacht House (851 Bayway Blvd, Clearwater, Fl 33767; phone: 727-441-8212; e-mail: cpoint7@knology.net); Clearwater Point 8 Shipmaster, Sail (800 S Gulfview Blvd, Clearwater, Fl 33767; phone: 727-442-0664; e-mail: clwpt8(d,tampabay.rr.com); Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: papamurphy-(i4aol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725- 3345; email: Diwna,Qte.net). Presenter: Wayne M. Wells, AICP, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 12 of 14 3. Case: FLD2005-0706342 Hamden Drive and 343 Coronado T Level Two Application Owner/Applicant: Je? and Teresa Tas. Representative: Keith Zayac; Keith Zayac and Associates (701 Enterprise Road, Suite 404 Safety Harbor, FL 34695; phone: 727-793-9888; fax: 727-793-9855; email: keithLa)keithzayac.com). Location: 0.35 acres located on the south side of Brightwater Drive between Coronado and Hamden Drives. Atlas Page: 276A. Zoning District: Tourist (T) District. Request: (1) Termination of Status of Nonconformity for density (27 existing overnight accommodation units to be converted to 20 attached dwelling units, where a maximum of 10 dwelling units would be permitted under current Code), under the provisions of Section 6-109; and (2) Flexible Development approval to permit 20 attached dwellings within the Tourist (T) District with an increase to building height from 35 feet to 83 feet (to roof deck) with an additional seven feet for perimeter parapets (from roof deck) and an additional 18 feet for architectural embellishments (from roof deck), a reduction to the front (north) setback from 15 feet to 14.94 feet (to building) and zero feet (to pavement), a reduction to the front (west) setback from 15 feet to 14.88 (to building/pavement), a reduction to the side (south) setback from 10 feet to zero feet (to pavement), and a reduction to the minimum lot width from 100 feet to 67.5 feet along Coronado Drive and to 71.64 feet along Hamden Drive as part of a Comprehensive Infill Redevelopment Project, under the provisions of Section 2-803.C. Proposed Use: Attached dwellings. Neighborhood Associations: Clearwater Beach Association (Jay Keyes, 100 Devon Drive, Clearwater, FL 33767: phone: 727-443-2168; email: pqpamurphy(@,aol.com.); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-7253345; email: Djw(&e.net). Presenter: Robert G. Tefft, Planner III. Community Development Board Consent Agenda - September 20, 2005 - Page 13 of 14 4. Case: FLD2003-08039 - ep, 1470 and 1480 South Missouri Avenu Level Two Application Owners/Applicants: Peter and Kelly L. Nascarella and KP23 Enterpri s, Inc. Representative: Gerald A. Figurski, Esquire (2550 Permit Place, New Port Richey, FL 34655; phone: 727-942-0733; fax: 727-944-3711; email: figgfhlaw.net). Location: 2.31 acres located on the west side of South Missouri Avenue, south of Bellevue Boulevard and 200 feet north of Woodlawn Street. Atlas Page: 314A. Zoning District: Commercial (C) District and Low Medium Density Residential District. Request: Flexible Development approval (1) to permit vehicle sales/display and an automobile service station in the Commercial District with reductions to the front (east) setback from 25 feet to five feet (to pavement), from 25 feet to 13.7 feet (to existing building) and from five feet to zero feet to retain existing signage (to the leading edge of the sign), reductions to the side (south) setback from 10 feet to 5.8 feet (to carport) and from 10 feet to 3.9 feet (to pavement), reductions to the rear (west) setback from 20 feet to 3.5 feet (to pavement and existing building), a reduction to required parking from 55 spaces to 30 spaces, an increase to sign height from 14 feet to 15 feet (for existing signage), a deviation to allow vehicle sales/display contiguous to residentially-zoned property, a deviation to allow the display of vehicles for sale outdoors and a deviation to allow direct access to a major arterial street, as a Comprehensive Infill Redevelopment Project, under the provisions of Section 2- 704.C, and reductions to the landscape buffer width along South Missouri Avenue from 15 feet to five feet (to pavement) and from 15 feet to 13.7 feet (to existing building), a reduction to the landscape buffer width along the south property line from five feet to 3.9 feet (to pavement), a reduction to the landscape buffer width along the west property line adjacent to single family dwellings from 12 feet to 5.8 feet (to pavement), a reduction to the landscape buffer width along the west property line adjacent to a nonresidential use from five feet to 3.5 feet (to pavement and existing building), a reduction to the foundation landscaping adjacent to buildings from five feet to zero feet and a reduction to reduce the interior landscape area from 10 percent to 7.45 percent of the vehicular use area, as a Comprehensive Landscape Program, under the provisions of Section 3-1202.G; and (2) to permit non-residential off-street parking in the Low Medium Density Residential District, with a deviation to allow landscaping on the inside of a perimeter fence, as a Residential Infill Project, under the provisions of Section 2-204.E. Proposed Use: Vehicles display and sales. Neighborhood Associations: South Clearwater Citizens for Progress (Duke Tieman, 1120 Kingsley Street, Clearwater, FL 33756; email: duketiemangaol.com); Clearwater Neighborhoods Coalition (Doug Williams, President, 2544 Frisco Drive, Clearwater, FL 33761; phone: 727-725-3345; email: Djw@ e.net). Presenter: Wayne M. Wells, AICP, Planner III. 1. ADJOURNMENT S: (Planning Department)C D &4gendas DRC & CDBICDBI2005W9 September 20, 20051CDB Consent Agenda September 20, 2005.doc Community Development Board Consent Agenda - September 20, 2005 - Page 14 of 14 FLD2005-07063, (42) BAKER, GREGORY IRARNES, ENOCH IRENNETT, JASON BAKER; CHERYL R BARNES, RUBYE L 1015 N BETTY LN 1116 ?AIRBURN AVE 1020 N BETTY LN CLEARWATER FL 33755 - 3302 CLEARWATER FL 33755 - 3318 CLEARWATER FL 33755 - 3301 BIRT, ANNIE W BLUNT, ALICE BRADLEY, TERRY A 1009 N BETTY LN BLUNT, DERICK E BRADLEY, KAREN T CLEARWATER FL 33755 - 3302 1201 FAIRBURN AVE 1010 PINEBROOK DR CLEARWATER FL 33755 - 3321 CLEARWATER FL 33755 - 3432 BULLOCK, ELVENA CARPENTER, DONALD C CARTER, W MILES THE 1107 N BETTY LN CARPENTER, CONNIE J 1115 N BETTY LN CLEARWATER FL 33755 - 3304 1008 PINEBROOK DR CLEARWATER FL 33755 - 3304 CLEARWATER FL 33755 - 3432 Clearwater Neighborhoods Coalition COOPER, WAYNE H DE BUSK, PEGGY A Doug Williams, President MAJOR-COOPER, CHERYL 1315 OVERLEA ST 2544 Frisco Drive 1020 FAIRBURN AVE CLEARWATER FL 33755 - 3423 Clearwater, FL 33761 CLEARWATER FL 33755 - 3316 DILLARD, GEORGE DIMAS, WILLIAM C DOYLE, EVELYN M MOONEY, LUCRETIA A 1117 N BETTY LN 1325 LOTUS DR N 1525 STEVENSON DR CLEARWATER FL 33755 - 3304 DUNEDIN FL 34698 - 5410 CLEARWATER FL 33755 - 2648 EVANS, CASTELLA E EVERYBODY'S TABERNACLE INC FLOYD, THOMAS SR 1214 FAIRBURN AVE 1120 N BETTY LN FLOYD, ELIZABETH O CLEARWATER FL 33755 - 3320 CLEARWATER FL 33755 - 3303 1471 FAIRMONT ST CLEARWATER FL 33755 - 2753 GODWIN, JACQUELINE L HOMELESS EMERGENCY PROJECT KIRTLEY, JAMES L 1231 PALMETTO ST INC KIRTLEY, CAROL CLEARWATER FL 33755 - 4334 1120 N BETTY LN 1018 PINEBROOK DR CLEARWATER FL 33755 - 3303 CLEARWATER FL 33755 - 3432 Lafferty Architecture Group, LLC LUDEKER, CATHERINE MC ABEE, DAVID Stephen B. Lafferty, AIA 1016 PINEBROOK DR MC ABEE, PATRICIA 11414 Seminole Boulevard, Suite 5 CLEARWATER FL 33755 - 3432 1204 FAIRBURN AVE Largo, Florida 33778 CLEARWATER FL 33755 - 3320 PATELLA, RONALD PINELLAS BD OF PUB INST PINELLAS BD OF PUB INST PATELLA, ELIZABETH M PO BOX 2942 PO BOX 2942 1022 PINEBROOK DR LARGO FL 33779 - 2942 LARGO FL 33779 - 2942 CLEARWATER FL 33755 - 3432 POLLOCK, ALBERT EST PUGH, HENRIETTA W RICHARDSON, SHERI C 1021 FAIRBURN AVE 1208 FAIRBURN AVE JONES, ESSIE M CLEARWATER FL 33755 - 3317 CLEARWATER FL 33755 - 3320 1124 FAIRBURN AVE CLEARWATER FL 33755 - 3318 RICHEY, AT F WERGEANT ALLEN MOORE COMNTY *SGT ALLEN MOORE COMNTY 1309'?JVERLEA ST PT PTNSHP CLEARWATER FL 33755 - 3423 1201 N BETTY LN 1201 N BETTY LN CLEARWATER FL 33755 - 3306 CLEARWATER FL 33755 - 3306 STAGG, JAMES E 3332 OLD COX RD CHASE CITY VA 23924 - THOMAS, CALVIN E WATTS, BARBARA 1012 PINEBROOK DR CLEARWATER FL 33755 - 3432 TINSLEY, JAMES S 1408 N BETTY LN CLEARWATER FL 33755 - 2607 WHARRAN, WILLIAM WHEATON, JOANNE M WHITE, JENNIFER D WHARRAN, LYNN 4632 FRANKLIN AVE 1101 N BETTY LN 1014 PINEBROOK DR LOS ANGELES CA 90027 - 4202 CLEARWATER FL 33755 - 3304 CLEARWATER FL 33755 - 3432