Loading...
FLS2005-06040 (2) Planning Department CASE #: (_ S oZ Cleamater 100 South Myrtle Avenue DATE RECEIVED: Clearwater, Florida 33756 RECEIVED BY (staff Initials): Telephone: 727-562-4567 ATLAS PAGE #: Fax: 727-562-4865 ZONING DISTRICT: LAND USE CLASSIFICATION: ? SUBMIT ORIGINAL SIGNED AND NOTARIZED APPLICATION SURROUNDING USES OF ADJACENT PROPERTIES: ? SUBMIT 14 COPIES OF THE ORIGINAL APPLICATION including NORTH: 1) collated, 2) stapled and 3) folded sets of site plans SOUTH: WEST: ? SUBMIT APPLICATION FEE $ EAST: oat P6 - oft * NOTE: 15 TOTAL SETS OF INFORMATION REQUIRED (APPLICATIONS PLUS SITE PLAN SETS) URIE FLEXIBLE STANDARD DEVELOPMENT APPLICATION (Revised 12/30/2004) L L) T --PLEASE TYPE OR PRINT-- A. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4-202.A) APPLICANT NAME: ?? Y7 i?? S L- G • G MAILING ADDRESS: Z-6-3Z yp/i/P P7 fo ` fir/ it e- 6/e r ci ' r ?1 3'3761 PHONE NUMBER: 7.z'7 787 - G/ V (, FAX NUMBER: PROPERTY OWNER(S): /;Q . ) q_5 G 17 c/ S c i% L_ . L-• C , (Must inclu e ALL owners as listed on the creed - provide original signature(s) on page 6) AGENT NAME: 61zt_Q gr C? - p e, -,a e,--s Z!q27_'Q r r7 f X MAILING ADDRESS: 9d/ 14erGUlP,s' 14 ye- Sui7?f ??fPrrrcyrtfiPr. I-/ 33;76,S PHONE NUMBER: 7 Z--) - `7``/7 FAX NUMBER: 7Z7 - 1/9 7 y I CELL NUMBER: E-MAIL ADDRESS: B. PROPOSED DEVELOPMENT INFORMATION: (Code Section 4-202.A) STREET ADDRESS of subject site: /,?) -L A_I• /SP?c ?Fr /Cc(• Cleo r afP_[ F1• -3376'?_ LEGAL DESCRIPTION: l Q 7 Z -77Q 7th P wS,//Vi'F 1.51"'.17 RPD/Qt r Pict?' k • / o 9 %?a 1e. 3 Co (if not listed here, plea 3e note the location of this document in the submittal) PARCEL NUMBER: C> /- Z 9-/.S- - S•S!S-O - 0 0 0 - 0 0 Z a PARCEL SIZE: b [ /g r re S /79 O • i (acres, square feet) PROPOSED USE(S) AND SIZE(S): 0,17(- /O/6"0 SF O 0C(-iCe t,??"? t 4 - Z J t aY ?? (number of dwelling units, hotel rooms or square footage of nonresidential se) -- DESCRIPTION OF REQUEST(S): tern-^ 5P ? 6:? r (t r a a e-f P y i'/CJ: 3 . /-/e,`' 19 L IL Attach sheets and be specific when identifying the request (include all requested code deviations; e.g. reduction in req d number arking spaces, specific use, etc.) Page 1 of 6 - Flexible Standard Development Application 2005-0"M I CleaMN 17 2005 AL hip PIA NNit,K; a, i t 3?w( / A 0 • ORIGINAL DOES THIS APPLICATION INVOLVE THE TRAN.;FER OF DEVELOPMENT RIGHTS (TDR), A PREVIOUSLY APPROVED PLANNED UNIT DEVELOPMENT, OR A PREVIOUSLY APPROVE.) (CERTIFIED) SITE PLAN? YES _ NO (if yes, attach a copy of the applicable documents) C. PROOF OF OWNERSHIP: (Code Suction 4-202.A.5) Ilia/ SUBMIT A COPY OF THE TITLE INSURANCE POLICY, DEED TO THE PROPERTY OR SIGN AFFIDAVIT ATTESTING OWNERSHIP (see page 6) D. C1 1. WRITTEN SUBMITTAL REQUIRER`.ENTS: (Code Section 3-913.A) Provide complete responses to the six (6) GENERAL APPLICABILITY CRITERIA- Explain how each criteria is achieved, in detail: The proposed development of the land will bz in harmony with the scale, bulk, coverage, density and character of adjacent properties in which it is located. 1 0on.•.irrC;rA7 DRvt(oamen! Igc!,'rcant %O 2. The proposed development will not hinder or discourage the appropriate development and use of adjacent land and buildings or significantly impair the value thereof. 6A £W, ort 44 ,7 ri ee,? f' Cann c1 S ai" t3cr: / rl s --- 3. The proposed development will not adversely affect the health or safety or persons residing or working in the neighborhood of the proposed use. iD, /.5 h SJr o?-klce ic 4. The proposed development is designed to minimize traffic congestion. -S ce -f-4 Pn7lf-gr- a 01-1 Pi Ci' S 5. The proposed development is consistent with the community character of the immediate vicinity of the parcel proposed for development. C 0 rrr n" C, r G r c( D r -y'e 0 /n F-? f'4 ;-4i r c.,- a 7' 7-6 S %L 6. The design of the proposed development minimizes adverse effects, including visual, acoustic and olfactory and hours of operation impacts, on adjacent properties. n ?-?iG? ?ra:l C?•nc -• yn? 7% ?YIN SIG (t r-t t'JF 07?P_P'C..1 /G?17 U Provide complete responses to the applicable flexibility criteria for the specific land use as listed in each Zoning District to which the waiver is requested (use separate sheets as necessary) -1Explain _ how each criteria is achieved, in detail: j /1 'Q ?dVPr7tt???I ?'VCGIL G? i ?! Le z-r7' O d-eet. - Page 2 of 6 - Flexible Standard Development Application 2005- City 4!JTIUJN D r--10 / 5 PIANra•, & DE Eiof-?rcta3 SVICS F-J aRIGINAL E. STORMWATER PLAN SUBMITTAL REQUIREMENTS: (City of Clearwater Storm Drainage Design Crite Manual and 4-202.A.21) A STORMWATER NARRATIVE MUST BE SUBMITTED WITH ALL APPLICATIONS. All applications that invo addition or modification of impervious surface, including buildings, must include a stormwater plan that demonstrates compliance with I City of Clearwater Storm Drainage Design Criteria manual. A reduction in impervious surface area does not qualify as an exemption this requirement. If a plan is not required, the narrative shall provide an explanation as to why the site is exempt. O? At a minimum, the STORMWATER PLAN shall include the following: _ Existing topography extending 50 feet beyond all property lines; Proposed grading including finished floor elevations of all structures; All adjacent streets and municipal storm systems; _Le' Proposed stormwater detention/retention area including top of bank, toe of slope and outlet control structure; A narrative describing the proposed stormwater control plan including all calculations and data necessary to demonstrate compliance with the City manual. Z Signature and seal of Florida Registered Professional Engineer on all plans and calculations. (3? COPY OF PERMIT INQUIRY LETTER OR SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT (SWFWMD) PERMIT SUBMITTAL (SWFWMD approval is required prior to issuance of City Building Permit), if applicable Q"' Acknowledgement of stormwater plan requirements (Applicant must initial one of the following): /IQ /'i- Stormwater plan as noted above is included Stormwater plan is not required and explanation narrative is attached. At a minimum, a grading plan and finished floor elevations shall be provided. CAUTION - IF APPLICATION REVIEW RESULTS IN THE REQUIREMENT FOR A STORMWATER PLAN AND NONE HAS BEEN SUBMITTED, APPLICATION MUST BE RESUBMITTED AND SIGNIFICANT DELAY MAY OCCUR. If you have questions regarding these requirements, contact the City Public Works Administration Engineering Department at (727) 562-4750. F. SUPPLEMENTAL SUBMITTAL REQUIREMENTS: (Code Section 4-202.A) 1;l,,/ SIGNED AND SEALED SURVEY (including legal description of property) - One original and 14 copies; ? TREE SURVEY (including existing trees on site and within 25' of the adjacent site, by species, size (DBH 4" or greater), and location, including drip lines and indicating trees to be removed) - please design around the existing trees; IRX LOCATION MAP OF THE PROPERTY; ? PARKING DEMAND STUDY in conjunction with a request to make deviations to the parking standards (ie. Reduce number of spaces). Prior to the submittal of this application, the methodology of such study shall be approved by the Community Development Coordinator and shall be In accordance with accepted traffic engineering principles. The findings of the study will be used in determining whether or not deviations to the parking standards are approved; V "'GRADING PLAN, as applicable; ? PRELIMINARY PLAT, as required (Note: Building permits will not be issued until evidence of recording a final plat is provided); ? COPY OF RECORDED PLAT, as applicable; G. SITE PLAN SUBMITTAL REQUIREMENTS: (Section 4-202.A) ITE PLAN with the following information (not to exceed 24"x 36"): r y All dimensions; D r'C, `?? !f North arrow, Engineering bar scale (minimum scale one inch equals 50 feet), and date prepared; I Location map; package; ?1JN 17 ?nC l Index sheet referencing individual sheets included in UJ ' r Footprint and size of all EXISTING buildings and structures; Footprint and size of all PROPOSED buildings and structures; ± 1 All required setbacks; P(W lf? All existing and proposed points of access; All required sight triangles; Identification of environmentally unique areas, such as watercourses, wetlands, tree masses, and specimen trees, including description and location of understory, ground cover vegetation and wildlife habitats, etc; Page 3 of 6 - Flexible Standard Development Application 2005- City of Clearwater Location of all public and private easements; Location of all street rights-of-way within and adjacent to the site; Location of existing public and private ut"ities, including fire hydrants, storm and sanitary and water lines; All parking spaces, driveways, loading areas and vehicular use areas; Depiction by shading or crosshatching of all required parking lot interior landscaped are Location of all solid waste containers, recycling or trash handling areas and outside me Section 3-201(D)(i) and Index #701); Location of all landscape material; Location of all onsite and offsite storm-water management facilities; Location of all outdoor lighting fixtures; and c!/? Location of all existing and proposed sidewalks. Q SITE DATA TABLE for existing, required, and proposed development, in written/tabular form Land area in square feet and acres; sewer lines, manholes and lift stations, gas as; chanical equipment and all required screening (per Number of EXISTING dwelling units; Number of PROPOSED dwelling units; Gross floor area devoted to each use; _ Parking spaces: total number, presentee in tabular form with the number of required spaces; Total paved area, including all paved pa king spaces and driveways, expressed in square feet a id percentage of the paved vehicular area; Size and species of all landscape mate, al; Official records book and page number: of all existing utility easement; Building and structure heights; Impermeable surface ratio (I.S.R.); and ? Floor area ratio (F.A.R.) for all nonresid;,ntial uses. 0,'/REDUCED SITE PLAN to scale (8'r4 X 11) and color rendering if possible; I/OR DEVELOPMENTS OVER ONE ACRE, ?rovide the following additional information on site plan: / One-foot contours or spot elevations on site; r? Offsite elevations if required to evaluate the proposed stormwater management for the parcel; All open space areas; _?? Location of all earth or water retaining walls and earth berms; / Lot lines and building lines (dimensioned); ?/ Streets and drives (dimensioned); ???? Building and structural setbacks (dimensioned); Structural overhangs; Tree Inventory; prepared by a "certified arborist", of all trees 8" DBH or greater, reflecting size, canopy (drip lines) Gnd condition of such trees. H. LANDSCAPING PLAN SUEMITTA_ REQUIREMENTS: (Section 4-1102.A) LANDSCAPE PLAN: All existing and proposed structures; Names of abutting streets; Drainage and retention areas including wales, side slopes and bottom elevations; Delineation and dimensions of all required perimeter landscape buffers; Sight visibility triangles; Delineation and dimensions of all parkir;g areas including landscaping islands and curbing; Proposed and required parking spaces;. Existing trees on-site and immediately adjacent to the site, by species, size and locations, including driplines (as indicated on / required tree survey); J Plant schedule with a key (symbol or label) indicating the size, description, specifications and quantities of all existing and proposed J landscape materials, including botanical and common names; Location, size, and quantities of all existing and proposed landscape materials, indicated by a key relating to the plant schedule; Typical planting details for trees, palms, shrubs and ground cover plants including instructions, soil mixes, backfilling, mulching and protective measures; Interior landscaping areas hatched and or shaded and labeled and interior landscape coverage, expressing in both square feet and percentage covered; - Conditions of a previous development approval (e.g. conditions imposed by the Community Development Board); Irrigation notes. C/' REDUCED LANDSCAPE PLAN to scale (8 % X 11) (color rendering if possible); G IRRIGATION PLAN (required for level two and three approval); El COMPREHENSIVE LANDSCAPE PROGRAM application, as applicable. Landscape associated with the Comprehensive Landscape Program shall exceed minimum Code requirements to offset the areas where minimum Code will not be met. JUN 17 2005 Page 4 of 6 - Flexible Standard Development Application 2005- City of BUILDING ELEVATION PLAN EMMITTAL REQUIREMENTS: (Section 4-202.A.23) Required in the event the application includes a development where design standards are in issue (e.g. Tourist and Downtown Districts) or as part of a Comprehensive Infill Redevelopment Project or a Residential Infill Project. ? BUILDING ELEVATION DRAWINGS - all sides of all buildings including height dimensions, colors and materials; ? REDUCED BUILDING ELEVATIONS - four sides of building with colors and materials to scale (8 % X 11) (black and white and color rendering, if possible) as required. IGNAGE: (Division 19. SIGNS / Section 3-1806) All EXISTING freestanding and attached signs; Provide photographs and dimensions (area, height, etc.), indicate whether they will be removed or to remain. ? All PROPOSED freestanding and attached signs; Provide details including location, size, height, colors, materials and drawing; freestanding signs shall include the street address (numerals) Comprehensive Sign Program application, as applicable (separate application and fee.required). C3 Reduced signage proposal (8 Y2 X 11) (color), if submitting Comprehensive Sign Program application. K. TRAFFIC IMPACT STUDY: (Section 4-202.A.13 and 4-801.C) O Include if required by the Traffic Operations Manager or his/her designee or if the proposed development: • Will degrade the acceptable level of service for any roadway as adopted in the Comprehensive Plan. • Will generate 100 or more new vehicle directional trips per hour and/or 1000 or more new vehicle trips per day. • Will affect a nearby roadway segment and/or intersection with five (5) reportable accidents within the prior twelve (12) month period or that is on the City's annual list of most hazardous intersections. Trip generation shall be based on the most recent edition of the Institute of Transportation Engineer's (ITE) Trip General Manual. The Traffic Impact Study must be prepared in accordance with a "Scoping Meeting" held with the Traffic Operations Manager and the Planning Department's Development Review Manager or their designee (727-562-4750) Refer to Section 4-801 C of the Community Development Code for exceptions to this requirement. Acknowledgement of traffic impact study requirements (Applicant must initial one of the following): Traffic Impact Study is included. The study must include a summary table of pre- and post-development levels of service for all roadway legs an each turning movement at all intersections i entified in the Scoping Meeting. ' r > l 4tSe. cr S j2r j jf.> , ?6T ,Cc 404 Tri%sj Impact Study is not required. `L r AC, 9'' 2-,1J15- 10C fiPaticc e v ci.tv_" t # CYC@l'ec' '?- C'c t7? r veil CAUTION - IF APPLICATION REVIEW RESULTS IN THE REQUIREMENT FOR A TRAFFIC IMPACT STUDY AND NONE HAS BEEN SUBMITTED, APPLICATION MUST BE RESUBMITTED AND SIGNIFICANT DELAY MAY OCCUR. If you have questions regarding these requirements, contact the City Public Works Administration Engineering Department at (727) 562-4750. 4. SIGNATURE: 1,; the undersigned, acknowledge that all representations made in this application are true and accurate to the best of my knowledge and authorize City representatives to visit and photograph the property described in this application. Signature of property owner or representative STATE OF FLORIDA, COUNTY OF PINELLAS Sworn to and subscribed before me this day of 3,,1 A.D. 2005- to me and/or by ff E Q,q s who is personallyknown has produced as w Notary blic, J ARY PUB11C-STkTE OF FLORIDA My commission expires: W T n„rnn Mnnidn Commission #DD398205 Expires; MAR. 30, 2009 Bonded Thru Atlantic Bonding Co., Inc. Page 6 of 7 - Flexible Development Comprehensive Infill Application 2005- City of Clearwater • *ORIGINAL 1. BUILDING ELEVATION PLAN SUBMITTAL REQUIREMENTS: (Section 4-202.A.23) Required in the event the application includes a development where design standards are in issue (e.g. Tourist and Downtown Districts) or as part of a Comprehensive Infill Redevelopment Project or a Residential Infill Project. ? BUILDING ELEVATION DRAWINGS - all sides of all buildings including height dimensions, colors and materials; Q REDUCED BUILDING ELEVATIONS - four sides of building with colors and materials to scale (8 % X 11) (black and white and color rendering, if possible) as required. J. SIGNAGE: (Division 19. SIGNS / Section 3-1806) / l EXISTING freestanding and attached signs; Provide photographs and dimensions (area, height, etc.), indicate whether they will be removed or to remain. ? All PROPOSED freestanding and attached signs; Provide details including location, size, height, colors, materials and drawing; freestanding signs shall include the street address (numerals) ? Comprehensive Sign Program application, as applicable (separate application and fee required). ? Reduced signage proposal (8'%X 11) (color), if submitting Comprehensive Sign Program application. K. TRAFFIC IMPACT STUDY: (Section 4-202.A.13 and 4-801.C) ? Include if required by the Traffic Operations Manager or his/her designee or if the proposed development: • Will degrade the acceptable level of service for any roadway as adopted in the Comprehensive Plan. Will generate 100 or more new vehicle directional trips per hour and/or 1000 or more new vehicle trips per day. • Will affect a nearby roadway segment and/or intersection with five (5) reportable accidents within the prior twelve (12) month period or that is on the City's annual list of most hazardous intersections. Trip generation shall be based on the most recent edition of the Institute of Transportation Engineer's (ITE) Trip General Manual. The Traffic Impact Study must be prepared in accordance with a "Scoping Meeting` held with the Traffic Operations Manager and the Planning Department's Development Review Manager or their designee (727-562-4750) Refer to Section 4-801 C of the Community Development Code for exceptions to this requirement. O Acknowledgement of traffic impact study requirements (Applicant must initial one of the following): Traffic Impact Study is included. The study must include a summary table of pre- and post-development levels of service for all roadway legs and each turning movement at all intersections identified in the Scoping Meeting. Traffic Impact Study is not required. CAUTION - IF APPLICATION REVIEW RESULTS IN THE REQUIREMENT FOR A TRAFFIC IMPACT STUDY AND NONE HAS BEEN SUBMITTED, APPLICATION MUST BE RESUBMITTED AND SIGNIFICANT DELAY MAY OCCUR. If you have questions regarding these requirements, contact the City Public Works Administration Engineering Department at (727) 562-4750- L. SIGNATURE: I, the undersigned, acknowledge that all representations made in this STATE OF FLORIDA, COUNTY OF PINELLAS 'T/A application are true and accurate to the best of my knowledge and Swo?rr to and subscribed before me this 1 y day of authorize City representatives to visit and photograph the property "?'ot 14 IF A. D. 20Q S- to or by described in this application. a a. who is personally known s produ ed as • / /? ny, _ ? identification. J /??i1.(.Lcte_._ Signatur f property own or epresen ative Notary p My co Ission expires: 0 NOTARY PUBLIC- STATE OF FLORIDA 1, -1 COMMISSION # DD275254 EXPIRES 01/03/2008 ? ''??CC BONDED THRU 1-888-NOTARYI e of -?1j exible 3ta 5d De o ent Application 2005- City of Clearwater FLANN:NG & DF%-? LO'-.' ,,! ri' T S'JCSI _-- _. CITY OF Q _r ?: ,Y Y- ,n T 0 IGINAL AFFIDAVIT TO AUTHORIZE AGENT: Rep/\-j 7' Sj3 Lf-(Names of all property owners on deed - please PRINT full names) 1. That (I am/we are) the owner(s) and record title holder(s) of the following described property (address or general location): 2. That this property constitutes the property for which a request for a: describe request) 3. That the undersigned (has/have) appointed and (does/do) appoint: Co j c Z' y pc'-41?-41 a-) as (hisAheir) agent(s) to execute any petitions or other documents necessary to affect such petition; 4. That this affidavit has been executed to induce the City of Clearwater, Florida to consider and act on the above described property; 5. That site visits to the property are necessary by City representatives in order to process this application and the owner authorizes City representatives to visit and photograph the property described in this application; 6. That (IAve), the undersigned authority, hereby certify that the foregoing is true and correct. Property ner Property Owner Property Owner Property Owner STATE OF FLORIDA, COUNTY OF PINELLAS Before me the undersigned, an officer duly commissioned by the laws of theAt to orida, on this /L1 7? day of `TL f ???G ZO personally appeared 6FiA445 E e /9-)/P f' who having been first duly sworn Deposes and says that he/she fully understands the contents of the affidavit that he/she signed. N aryublic My Commission Expires: JOHN SITETZAKI-S COMMISSIOSTATE D275254 EXPIRES 01/0312008 90NCED THRU 1-8WNOTARYI SAPlanning 0epartmenttApplication Formsldevelopmcnt reviewltlexible standard development application 2005.doc 1 ? l l y JU14 17 2005 PLANNING & DE" CITY QF Page 6 of 6 - Flexible Standard Development Application 2005- City of Clearwater • LL () Planning and Development Services rw ater 100 South Myrtle Avenue >- Clearwater, Florida 33756 ?Clea 'u Telephone: 727-562-4567 U Fax: 727-562-4576 ? SUBMIT ORIGINAL SIGNED AND NOTARIZED APPLICATION ? SUBMIT 1 COPY OF THE ORIGINAL APPLICATION including folded site plan CAPE #: DATE RECEIVED: RECEIVED BY (staff initials): ATLAS PAGE #: ZONING DISTRICT: LAND USE CLASSIFICATION: ZONING & LAND USE CLASSIFICATION OF ADJACENT PROPERTIES: NORTH: / SOUTH: / WEST: / EAST: / ORIGINA-1 COMPREHENSIVE LANDSCAPE PROGRAM REQUIREMENTS (Revised 9/1912001) D. APPLICANT, PROPERTY OWNER AND AGENT INFORMATION: (Code Section 4-1001) 7 APPLICANT NAME: `I A C- APPLICANT ADDRESS: ? 3 Z-. Ve- ) '/ E'''C ?-S J2 ' PHONE NUMBER: 7 7- j? PROPERTY OWNER(S): (Must Include ALL owners) FAX NUMBER: AGENT NAME: (Contact Person) MAILING ADDRESS:.( 3 r PHONE NUMBER: 7 . 7^ FAX NUMBER: ( 7 7 / y 7 ' The landscaping requirements of Article 3 Division 12 may be waived or modified as a part of a Level One or Level Two Approval, as the case may be, if the application for development approval includes a Comprehensive Landscape Program, which satisfies the following criteria. The use of landscape plans; sections/elevations, renderings and perspectives may be necessary as supplementary information in addition to the information provided on this worksheet: 1. Architectural Theme. a. The landscaping in a Comprehensive Landscape Program shall be designed as a part of the architectural theme of the principal buildings proposed or developed on the parcel proposed for the development. The Landscape is in concert with the local development maximizing Landscape treatment and enhancing architectural themes. V - .U1 ZUU5 PLAt N;N; 3 C EV , :I SVCS Page i of c1l'y Q C?, t t t OR • ORIGINAL 2. b. The design, character, location and/or materials of the landscape treatment proposed in the Comprehensive Landscape Program shall be demonstrably more attractive than landscaping otherwise permitted on the parcel proposed for development under the minimum landscape standards. The Landscape treatment has been maximized on the property without jeopardizing drainage patterns, underground or overhead utilities, and the function of the building. Lighting. Any lighting proposed as a part of a Comprehensive Landscape Program is automatically controlled so that the lighting is turned off when the business is closed. Lighting will be controlled to be respectful of neighboring properties. 3. Community Character. The landscape treatment proposed in the Comprehensive Landscape Program will enhance the community character of the City of Clearwater. Landscape treatment is designed to give years of benefits without the disruption of building function, drainage and utilities. L? (,1-3 s U ??N1f2 Page 2 of 3 4. Property Values. The landscap*eatment proposed in the Comprehensive Landscape Program will have a beneficial impact on the value of the property in the immediate vicinity of the parcel proposed for development. The Landscape treatment will benefit value by providin aesthetically pleasing views while providing climate control for building and parking areas. 5. Special Area or Scenic Corridor Plan. The landscape treatment proposed in the Comprehensive Landscape Program is consistent with any special area or scenic corridor plan which the City of Clearwater has prepared and adopted for the area in which the parcel proposed for development is located. Please return checklist for review and verification. 6. That (1/we), the undersigned authority, hereby certify that the foregoing i e and correct. t 145 Property Owne Property Owner STATE OF FLORIDA, C0174W OF PMLLAS Before me the undersigned, ersigned, an officer duly commissioned by the laws of the State of Florida, o' s `? personally appeared ?L E ? &0"'1 -C, poses and says that helshe lly understands the contents of the affidavit that he/she sig My Commission Expires: C. ANTHONY EKONOIMIpE8 0 ?r can" o00n"s fig*" l/tr"e ` a ?a1d?d riu (!O )=4254 ?'f °uw?I?f fioAda Nowy Assn.. ft S: application forms/development review/comprehensive landscape program application.doc 1 L. been first d 1 7 2005 IdF jui, i j I PfAPJN;NO & D? t L r .. Ts- QTY Q7 Page 3 of 3 - T, TOWNSHIP 29 Ir4sG i iw t 1dw ar di?IKi P't+jtaf d f IttO44 aetr? OR V.aYdd MNS'aA W ?pnd.? Iw t aaenry.4tntnCmnellW mmW Q4 d. b /KG lw ? C y i w 1 172 ecrrt're+slm Tt VNGt] mr.l Au ]1ia.aemoc MNMAMD Un war. +'0.G, 1Ci]M1 4161 . A ><6 ? 7 wNlna a1p?t _, 12. . ail I 5UMOWLf 3JULEYAhO + ????s- AtY iYm x w x I. ' ICB tiA^M 66dd JP OV QV Durrm f° 25 35 35 TTRM 35 20 _ f'15HRUn PIANIW4DCfA1L 35' O.C. PA TJV 1 {' A N 17 2M5 `T Ii. Nyotns u .ruwwaca?c?.www.wwr. w..+r. trtltetsD211 Ta FERTILIZATION '.AtW tld Troe N hs N AW.H N NdN W W)b.r E013a lr'ttl tsW natddeYKN p°l^ rdiMmdttKtlIWI. TiIY. ftllN?gaabnl/eold tlK rmtV K.dryK dMd IdaM Yt n{!. N btbte d Y. Ieot N. An?.lohotl xft I mt- 1•tl netts l ab Cram t•QI }?FAYb 1 aba0- a•tl nnaMo 14"Captri 4-tl dren taWY Tnw stNk4 pr aKS 1111dk-dY QrKar WahoiWOKmd1 NWr`.NYSiw ww..aw =I w ?M awy.we r•y~ A .e Mr ew Iti tlM1M MIe• /l TR!!.' pt WnW DLTAIL TRQ PnnlecrtoN DRNL Plant Matenal5 Schedule awA. aW at.r NtK faav a wa t. aeaerw.br aen.4xa.V er ]µ.W.14' a4 W beNpv aKA Nan OwKlw ]1t.ip.W U NIN I+ee. Ntal Mras• I «.. Ir M.Ir /. 10! uN laetw newt T.leeltiw Irt.1rN:, Iran. 4 ll I.yafnwu Ma at..MW a'K.Yq?, rat a I.R N!+'••'ll•• N!e°•°Tti 4be.MY•.rai 4. IDl -T-"- Zia t Ju1mKn•avu Iraan AeN apL.Ir.IC IQ! IA fteNaa./I. rleQ+re ]K•21'N:. ]4'M. IO OY Oa rYee+ WOK 1r N..4'.rr.•I.a'nye m law n,ta..n+.?• rme.Tw 2M,Wr.u•tl,•. ii TN r.dWtemn?- Vr.fd..Y6' ]rt•Irll..la'ar.. Ih TAI TNda./tnt. wl,e.law?f D..4 GOnk1ed11uM1•. 11t.ON.. lr y.. i Y atdr•? OYY1fY It] w Nwaww e•Pe°^ ] Irew vtn.• 3IC24 p. P4'tA•94t41 M• a w l,+et Ne. a +a?. wll.. t.a •atna arise la•x ICx avaa. " >o o< aYx Wx xx w is eb IV- !Yx I' x a 2a-a -- I dIF Il l? 0, z J co Lu 'V rp U O? v a E UJ U0 V) LL o a c ONC Li ~ D d Gw m U C 6 ? N a d CDA p oartxauor i LANDSCAPE T /1Vi ARCHITECTS d NYa taptNlw ty]ap-grl.lersleu te..TnT aster T.em n+417 ]oIT m w om foara.xwsla SHEET L-I 3ENMRALLANDSCAPE NOTE5 Ndei etNt WlNlloJtll ae W+Ntd.IbY{.tnan/dtMY. M1K. aNIN Prepared by and return to: George G. Pappas, P.A. 901 N. Hercules Ave., Ste. C Clearwater, FL 33765 GRANT OF EASEMENT '0 ORIGINAL KEN BURKE, CLERK OF COURT PINELLAS COUNTY FLORIDA INST# 20051233810410412005 at 01:39 PM OFF REC BK: 14219 PG: 1820-1823 DocType:EAS RECORDING: $35.50 THIS GRANT OF EASEMENT is made this P_ d y of March, 2005, by and between Pappas & Sons, L.L.C., a Florida limited company, whose address is 2632 Velventos Dr., Clearwater, FL 33761, herein referred to as first party, and Dimitrios and Anna Loukataris, husband and wife, whose address is 1868 Ridgeway Dr., Clearwater FL 33755, herein referred to as second party. WITNESSETH: That first and second party, for and inconsideration of $10.00 and other valuable consideration, the receipt and sufficiency of which is hereby acknowledged by first and second party, by these presents do hereby grant unto each other, their successors and assigns, a perpetual, nonexclusive easement over and upon all paved portions of that certain property located in Pinellas County, Florida, described as follows: See Exhibit "A". attached hereto and by reference made a part hereof. such easement to be used solely for the purpose of providing parking spaces for the vehicles of the first and second parties, their respective heirs, assigns, successors in interest, tenants, invitees, licensees or guests of occupants of the dominant estate together with the right of ingress and egress for both vehicular and pedestrial traffic thereto. First and Second Parties hereby represent and warrant that each granting party is authorized to enter into this Grant of Easement. First and Second Party each reserves and retains all right, title, interest and privilege in the full use and enjoyment in, over, and across the easement for all purposes not inconsistent with the uses and rights granted hereafter. First Party further reserves and retains the rights to construct upon their respective parcel real property improvements including but not limited to enclosed building structures, driveways, walkways, landscape areas and other improvements which shall not constitute a violation of this agreement or action contrary to the interest of Second Party. Second Party further grants unto first party the rights, benefits and privileges to connect to and use all existing underground stormwater drainage lines and stormwater retention areas which shall run for the benefit of first and second party. Any created stormwater retention areas constructed upon First Party's parcel shall also be utilized for the benefit of Second Party. This easement is granted and accepted by First and Second Party subject to the following conditions that Grantee covenants and agrees to perform: 1. To use the said easement with due care and good faith. 2. To cause no unnecessary or unreasonable obstruction in the use of either,Rartys, rea?. property. U T5 ?(.JUN 17 fU85 F PuiNl: t t. _ f I SW ORIGINAL 3. To use the easement granted hereunder in such manner as to prevent the creation of any obstruction or condition that is or may become hazardous to either party, their guests, employees, invitees, licensees, or the general public. 4. To mutually indemnify and hold each other harmless from any and all claims for the payment of any compensation or damages for injury to persons (including wrongful death) or damage to property resulting from the use by the benefited party of the easement herein granted, together with any and all court costs and attorney's fees incurred by the granting party in connection with such claims. 5. Each party shall assume all liability and bear all expenses for the repair and maintenance of the easement property on each of their respective real property parcels. Notwithstanding, each party shall reimburse the respective burdened grantor for costs or repair and maintenance caused by the negligence of the benefited party, their guests, employees, invitees, licensees, heirs, assigns or successor in interest. 6. First and Second Party understand and agree that this easement is a nonexclusive easement and agrees to use the same with due consideration for the rights of the property owner and other easement holders, if any. -b- EXECUTED this instrument this a5 day of March, 2005. Witnesse , 1 Printed Name: 2 Printed NameL;15P-. re.c.JS STATE OF FLORIDA COUNTY OF PINELLAS First Party: Pappas & Sons, L. L. C. By , pa-Rl ? George E. Pappas, Managing Member The foregoing instrument was acknowledged before me this da arch, 2005, by George E. Pappas, Managing Member of Pap F & Sons, L.L.C., who is onall known to e or who has producedl . ,F1- as identification. LISA K. ANDREWS Notary Public, State of Florida NOTA UBL - My Comm. ExpiresAug. 17,2008 No. 00347694 Print Name: Commission No: My Commission Expires: ?Tr EXECUTED this instrument this4S d of March, 2005. JUN 17 2005 Second Party: PLAN t?i*J & Dl 4 z?:;....<r. -i r Dig rtos Louka aris A/1 q 4 z (J &?/ Anna' Lo'?kaiai;is 2 ORIGINAL STATE OF FLORIDA COUNTY OF PINELLAS The foregoing instrument was acknowledged before me this a"'? day of March, 2005 by Dimitrios and Anna Loukataris, w are personally known to me or who have produced as identification. LISA K. ANDREWS NO UBLI Notary Public, State Of Florida My Com nNo. . OD347694 1 7,2008 Name: Commission No: My Commission Expires: ORIGINAL EXHIBIT A AS TO FIRST PARTY: Lot 2, Mathews/Nielsen Replat, according to the map or plat thereof, as recorded in Plat Book 109, Page 36, of the Public Records of Pinellas County, Florida And A Portion of Lot 1, map or plat entitled Mathews/Nielsen Replat as recorded in Plat Book 109, Page 36 of the Public Records of Pinellas County, Florida; bounded and described as follows: Beginning at the Southwest corner of Lot 2, Mathews/Nielsen Replat and run 1) along the North right-of-way line of Sunnydale Boulevard, N 89°30'35" W, a distance of 23.67 feet; thence 2) leaving said right-of way line, through Lot 1, N 00°27'02" W, a distance of 112.00 feet; thence 3) continue through said Lot 1, S 89°30'35" E, a distance of 24.71 feet to the Northwest corner of Lot 2; thence 4) along the West boundary of said Lot 2, S 00°05'04" W, a distance of 112.00 feet to the point of beginning, said parcel containing 2709 square feet more or less. AS TO SECOND PARTY: Lot 1, Mathews/Nielsen Replat, according to the map or plat thereof, as recorded in Plat Book 109, Page 36, of the Public Records of Pinellas County, Florida Less and Except A Portion of Lot 1, map or plat entitled Mathews/Nielsen Replat as recorded in Plat Book 109, Page 36 of the Public Records of Pinellas County, Florida; bounded and described as follows: Beginning at the Southwest corner of Lot 2, Mathews/Nielsen Replat and run 1) along the North right-of-way line of Sunnydale Boulevard, N 89°30'35" W, a distance of 23.67 feet; thence 2) leaving said right-of way line, through Lot 1, N 00°27'02" W, a distance of 112.00 feet; thence 3) continue through said Lot 1, S 89°30'35" E, a distance of 24.71 feet to the Northwest corner of Lot 2; thence 4) along the West boundary of said Lot 2, S 00°05'04" W, a distance of 112.00 feet to the point of beginning, said parcel containing 2709 square feet more or less. jUN 17 2005 03/3012005 11:53 FAX U005 • State: FL County: Pinellas ORIGINAL Order #: 05-3144 3 Plant #: Commitment # Effective D ime: insurance #: Agent #: 3065`05-3144 Marc , 2005 @ 8:00 r C04-19749 A. Schedule A 1. Policy or Policies to be issued: ALTA LOAN (10-17-92) Proposed Insured Loan: Amount 2nd Proposed Insured Loan: Amount ALTA OWNER'S (10-17-92) Proposed Insured Owners: Amount PAPPAS AND SONS, LLC $300,000.00 2. The estate or interest in the land described or referred to in the Commitment and covered herein is: FEE SIMPLE and is at the effective date hereof vested in: ROGER W. MATHEWS, JR. and JACQUELYN F. MATHEWS, his wife 3. The land is described as follows: Lot 2, MATHEWS/NIELSEN REPLAT, according to the map or plat thereof, as recorded in Plat Book 909, Page 36, of the Public Records of Pinellas County, Florida. AND, A PORTION OF LOT 1, MAP OR PLAT ENTITLED MATHEWS / NIELSEN REPLAT, AS RECORDED IN PLAT BOOK 109, PAGE 36 OF THE PUBLIC RECORDS OF PIi ELL. kCOUNTY, FLORIDA; BOUNDED AND DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF LOT 2, MATHEWS / NIELSEN REPLAT AND RUN 1) ALONG THE NORTH RIGHT-OF-WAY LINE OF SUNNYDALE BOULEVARD, N 89°30'35" W, A DISTANCE OF 23.67 FEET; THENCE 2) LEAVING SAID RIGHT-OF-WAY Issued By: 2166'C04-19749 U--A-?--?- PAPPAS TITLE CORPORATION 28950 US 19 N., SUITE 102 JIM 1 f 2005 Countersigned Authorized Signatory C'LEARWATER, FL 33761 . r svc NOTE: This Commitment consists of insert pages labeled in Schedule A, Schedule B-Section 1, and Schedule BSectlon 2. This com`mdtnenlis of no force and effect unless all schedules are Included, along with any Rfdar pages incorporated by reference In the insert pages. Underwrller: TICOR TITLE INSURANCE ,, o3 i3o/?2005 11:53 FAX LO 006 LINE, THROUGH LOT 1, N 00°27'02" W, A DISTANCE OF 112.00 FEET; THENCE 3) CONTINUE THROUGH SAID LOT 11 S 89°30'35" E, A DISTANCE OF 24.71 FEET TO THE NORTHWEST CORNER OF LOT 2; THENCE 4) ALONG THE WEST BOUNDARY OF SAID LOT 2, S 00°05104" W, A DISTANCE OF 112.00 FEET TO THE POINT OF BEGINNING. SAID PARCEL CONTAPtING 2709 SQUARE FEET MORE OR LESS. ORIGINAL [tr?L?_UUIt ? 17 2005 '61 y Q:- NOTE: This Commitment consists of insert pages labeled in Schedule A, Schedule B-Section 1, and Schedule B-Section 2, This commitment is of no force and effect unless all schedules are included, along with any Rider pages incorporated by reference in the insert pages. Commitment #: File #: 05-3144 03/39/2005 11:54 FAX t60 0 7 Schedule B- Section 1 ORIGINAL The following are the requirements to be complied with: Instrument(s) creating the estate or interest to be insured must be approved, executed and filed for record to wit: a. Warranty Deed from ROGER W. MATHEWS, JR. and JACQUELYN F. MATHEWS, his wife to PAPPAS AND SONS, LLC conveying the land. b. Recording of cross parking ingress and egress burdening and benefiting Lot 2. NOTE: Spouse of individual(s), if any, to join in the above required instrument(s) OR the document must state that captioned property is not the homestead of the grantor/mortgagor. Payment of the full consideration to, or for the account of, the grantors or mortgagors. Payment of all taxes, charges, assessments, levied and assessed against subject premises, which are due and payable. Satisfactory evidence should be had that improvements and/or repairs or alterations thereto are completed; that contractor, subcontractors, labor and materialmen are all paid. Exceptions 3 and 4 of Schedule B - Section 2 of this commitment may be amended in or deleted from the policy to be issued if a survey, satisfactory to the Company, is furnished to Company. 6. Partial Release of Mortgage recorded in Official Records Book 8069, Page 5 and Consolidation, Modification and Spreader Agreement in O.R. Book 8069, page 14; Modification in O.R. Book 9558, page 1693 and O.R. Book 12016, page 848, of the Public Records of Pinellas County, Florida. Partial Release of that certain Assignment of Rents and Leases recorded in Official Records Book 8069, at Page 36, and Consolidation, Modification and Spreader Agreement in O.R. Book 8069, page 14; Modification in O.R. Book 9558, page 1693 and O.R. Book 12016, page 848, as to the land. Verification that taxes for the year 2004 and all prior years are paid in full. Company will require proof that ROGER W. MATHEWS, JR. and JACQUELYN F. 9. VXA HEWS, his wife were married continuously and without interruption from the date they d title to the captioned property to the current date. ire r JUN 17 2005 Pl.At,.. l {:SIY ... NOTE: This Commitment consists of Insert pages labeled in Schedule A, Schedule "action 1, and Schedule B-Section 2. This commitment is of no force and effect unless all schedules are Included, along with any Rider pages incorporated by reference In the Insert pages. commitment 9: File #: 05-3144 o3,,30!2005 11:54 FAX Lo 00.9 Schedule B -Section 2 ORIGINAL. Exceptions Schedule B of the policy or policies to be issued will contain exceptions to the following matters unless the same are disposed of to the satisfaction of the Company. Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date the proposed insured acquires for value of record the estate or interest or mortgage thereon covered by this Commitment. 21 Rights or claims of parties in possession not shown by the Public Records. Encroachments, overlaps, boundary lines disputes, and other matters which would be disclosed by an accurate survey and inspection of the premises, sements or claims of easements not shown by the Public Records. Taxes or special assessments which are not shown as existing liens by the public records. 6. Taxes and assessments for the year 2005 and subsequent years, which are not yet due and payable. 7. Restrictions, reservations and easements as indicated and/or shown on that certain Plat recorded in Plat Book 109, at Page 36, of the Public Records of Pinellas County, Florida. 8. Ingress/Egress Easement as contained in Deed recorded in O.R. Rook 8069 at Page 1, of the public records of Pinellas County, Florida. 9. Any future special lien/assessments imposed by City, County, and/or State. 10. Rights or claims of parties in possession under unrecorded Leases, if any. 11, All licences, inventory, fixtures, accounts receivable, accounts payable, trade names, matters deemed personal property and all other items connected with the on-going business conducted on the insured premises not normally considered real property are excluded from the terms and conditions of this commitment. NOTE: TAX ID#01 -29-15-55950-000-0020; Payment information for 2004 taxes; UNPAID; Gross amount $2,228.03. C_ r «UW11 117 2005 PIANNUVG & IiEk, l- ,2-0D3 ? ?.`{3J. bJ NOTE: This Commitment consists of insert pages labeled In Schedule A. Schedule B-Section 1, and Schedule B-Section 2 This commitment is of no force and effect unless all schedules sire included, along with any Rider pages incorporated by reference in the insert pages. Commitment #: File #: 05.3144 03130.12005 11:54 FAX IgL 003 ORIGINAL 1 Payment of any pending or certified charges/special lien/assessments including, but not limited to: Sanitation, Utility, Road Paving, Wastewater imposed by City, County, and/or State. NOTE: This county may have special lien/assessments imposed by the local municipality. These lien/assessments are not discovered in a title search or shown above. These special assessments typically create a lien on real property. The municipality which governs subject property must be contacted to verify payment status. 11. If requested, all applicable ALTA endorsements will be issued with the final loan policy, including, but not limited to, 4 X6,41 .9 Q, G. 11, 6.2, and . The Florida Endorsement F.9=-S. will be atthed to the final loan policy when issued without any deletions subject to compliance of all nderwriting requirements of company, receipt by company of survey meeting the requirements of Sec. 627.7842(1) (a), and subject to the Florida Department of Insurance Rules governing its issuance. If a deletion of any provision of the Form 9 Is required, no funds of the proposed insured lender will be disbursed by company or its policy issuing agent without first notifying the proposed insured lender of the deletion and then obtaining approval of the deletion from the proposed insured lender. If the proposed insured lender does not approve the deletion, company or its policy issuing agent shall be authorized to return the proposed insured lenders funds to the proposed insured lender and cancel this commitment. r f0 (b ???? i? zoos ?; NOTE: This Commitment consists of insert pages labeled in Schedule A, Schedule B-Section 1, and schedule B-Section 2. This commitment is of no force and effect unless all schedules are Included, along with any Rider pages incorporated by reference in the insert pages. Commitment #: File #: 05-3144 )3!301LO0a 11:55 FAX Prepared by Pappas Tide Corporation 28050 U.S. Highway 19 North, Suite 102 Clearwater, Florida 33761 File Number: C04-19749 • 0 General Warranty Deed Made this March 29, 2005 A.D. By Roger W. Mathews, Jr., and Jacquelyn Mathews, husband and wife, whose address is: , hereinafter called the grantor, to Pappas & Sons, LLC,a Florida Limited Liability Company, whose post office address is: 901 N. Hercules Avenue, Clearwater, FL 33765, hereinafter called the grantee: (Whenever used herein the term "grnntor and "grantee" include all the parties to this instrument and the heirs, legal representatives and assigns of individuals. and the successors and assigns of corporations) Witnesseth, that the grantor, for and in consideration of the stun of Ten Dollars, ($10.00) and other valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens, remises, releases, conveys and confirms unto the grantee, all that certain land situate in Pinellas County, Florida, viz: Lot 2, MATHEWS/NIELSEN REPLAT, according to the map or plat thereof, as recorded in Plat Book 109, Page 36, of the Public Records of Pinellas County, Florida. AND, A PORTION OF LOT 1, MAP OR PLAT ENTITLED MATHEWS / NIELSEN REPLAT, AS RECORDED IN PLAT BOOK 109, PAGE 36 OF THE PUBLIC RECORDS OF PINELLAS COUNTY, FLORIDA; BOUNDED AND DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF LOT 2, MATHEWS / NIELSEN RE-PLAT AND RUN 1) ALONG THE NORTH RIGHT-OF-WAY LINE OF SUhfNYDALE BOULEVARD, N 89°30'35" W, A DISTANCE OF 23.67 FEET; THENCE 2) LEAVING SAID RIGHT-OF-NAY LINE, THROUGH LOT 1, N 00°21'02" W, A DISTANCE OF 112.00 FEET; THENCE 3) CONTINUE THROUGH SAID LOT 1, S 89°30'35" E, A DISTANCE OF 24.71 FEET TO THE NORTHWEST CORNER OF LOT 2; THENCE 4) ALONG THE WEST BOUNDARY OF SAID LOT 2, S 00005'04" W, A DISTANCE OF 112.00 FEET TO THE POINT OF BEGINNING. SAID PARCEL CONTAINING 2709 SQUARE FEET MORE OR LESS, Parcel ID Number: Together with all the tenements, hereditarrtents and appurtenances thereto belonging or in anywise appertaining. To Have and to Hold, the stone in fee simple forever. And the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee simple; that the grantor has good right and lawful authority to sell and convey said land; that the grantor hereby fully warrants the title to said land and will defend the same against the lawful claims of all persons whomsoever; and that said land is free of all encumbrances except taxes accruing subsequent to December 31, 2005 . In Witness Whereof, the said grantor has signed and sealed these presents the day and year first above written. Signed, sealed and delve • in our presence: witness Printed Name 006O Z f' Q DEEE) Individual Warranty Decd . Legal on Face Closers' Choice ORIGINAL ...,QTY QF r t 5', oai3o: suus' FAX Prepared by: Pappas Title Corporation 28050 U.S. Highway 19 North, Suite 102 Clearwater, Florida 33761 File Number. C04-19749 County of Pinellas ORIGINAL The foregoing instrument was aciaio%vledged before me this Match 2 by Roger W, Mathew Jr., and Jacquelyn Mathews, husband and wife, who is/are personally }no- n to me or who has produced hoto id identification. Notary hli Print Name My Commissiou Expires: LISA K. ANDREWS Notary Public, State of Florida My Comm. Expires Aug.17, 2008 No. DD347694 I1 11j\I ?I?e??'JN Vi. . e VYVV CITY QF Z',f ... a :_? DEFT) Indiwidual Warrsnry Decd • Legal on Fuce Closers' Choice 0 G.J. HO mann Phone: (727) 844-7686 Professional Engineer Fax: (727) 844-7626 8620 Airway Blvd., New Port Richey, FL 34654 ORIGINAL. Q June 16, 2005 << JUN1720M $Ij 1V11?Otu City Of Clearwater - Municipal Service Bldg. °?. :S'i Planning and development Services, Building & Inspections Division PLANK ??? 100 South Myrtle Ave. #210 (2"d floor) Clearwater, Florida 33758-4748 Re: Proposed office Bldg. Located at 1822 N. Belcher Road, Lot 2 Flexible Standard Design Dear Mr. Perry: Enclosed is the following: 1. 15 sets of site construction plans with landscape plans 2. 15 sets of flexable standard development forms 3. 15 sets of Survey 4. Proof of Ownership Should you have questions, please contact me. Thank you for your assistance in this matter. Sincerely, Galen J. Hofma n, PE ?A1N 6/20/2005 •'I` Receipt #: 1200500000000005671 11:38:42AM Date: 06/20/2005 r Line Items: Case No Tran Code Description Revenue Account No Amount Paid FLS2005-06040 03 Flex Std-Commercial 010-341262 475.00 Line Item Total: $475.00 • Payments: Method Payer Initials Check No Confirm No How Received Amount Paid Check PAPPAS & SONS LLC jmc 1010 In Person 475.00 Payment Total: $475.00 0 THIS IS NOT A PERMIT. This is a receipt for an application for a permit. This application will be reviewed and you will be notified as to the outcome of the application. cReceipupt Page 1 of 1 solo, ORIGINAL FLS2005-06040 1822 N BELCHER RD Date Received: 06/20/2005 PAPPAS & SONS ZONING DISTRICT: IRT LAND USE: IL ATLAS PAGE: 262B PLANNER OF RECORD: NOT ENTERED CLWCoverSheet LONG RANGE PLANNING DEVELOPMENT REVIEW December 5, 2005 Mr. George Pappas 901 Hercules Avenue Suite C Clearwater, FL 33765 • C ITY OF C LEARWATER PLANNING DEPARTMENT POST OFFICE BOX 4748, CLEARWATER, FLORIDA 33758-4748 MUNICIPAL SERVICES BUILDING, 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE (727) 562-4567 FAX (727) 562-4865 SITE PLAN APPROVE CASE CASE TYPE DRC DATE E °?o - CDB DATE SIGNATURE DATE I RE: Development Order regarding case FLS2005-06040 at 1822 Belcher Road Dear Mr. Pappas: This letter constitutes a Development Order pursuant to Section 4-202.E of the Community Development Code. On August 4, 2005, the Development Review Committee (DRC) reviewed your application for Flexible Standard Development approval to construct a 10,150 square foot, two-story office building. The request includes an increase to the maximum building height from 25 feet to 36.5 feet, a side (north) setback reduction from 10 feet to three feet (to building), a side (north) setback reduction from 10 feet to zero feet (to pavement), a side (west) setback reduction from 10 feet to zero feet (to pavement), a front (east setback reduction from 25 feet to 20 feet (to pavement), and a front (south) setback reduction from 25 feet to 20 feet (to pavement), per Section 2-703.I. The DRC recommended approval of the applications with the following bases and conditions: Bases for Approval: 1. The proposal complies with Office criteria under the provisions of Section 2-703.I; 2. The plan complies with General Applicability Criteria under the provisions of Section 3-913; and 3. The proposed development is compatible with the surrounding area. Conditions of Approval: 1. That a tree preservation plan prepared by a Certified Arborist be provided, prior to the issuance of a site or building permit 2. That the tree survey and landscape plan be revised to show all replacement trees in the same location from which they were inadvertently removed, prior to building permit 3. That a sewer lateral constructed in accordance with City of Clearwater Contract Specifications and Standards Index # 305 shall be installed at developer's cost, prior to the issuance of a building permit; 4. That a Pinellas County right-of-way permit is required for all work taking place in Belcher Road right-of-way; FRANK HIBBARD, MAYOR BILL. JONSON, VICE-MAYOR JOHN DORAN, COUNCIL\iFa1BIiR HOYr HAMILTON, COUNC,I.MFMBER CAREEN A. PFTERSEN, COUNCILMEMBER "EQUAL EMPLOYMENT AND AFFIRMAT[VI? ACTION EMPLOYER" December 5, 2005 FLS2005-06040 Page 2 5. That cross-sections of existing and proposed grades at property lines showing no adverse impacts be provided prior to the issuance of a site or building permit; 6. That modifications of the SWFWMD permit be provided prior to the issuance of a site or building permit; 7. That a 35% Littoral Zone concentrated near the pond outfall be provided prior to the issuance of a site or building permit; 8. That a written narrative, including discussion on methodology, history, hydrology, hydraulics and basis for all assumptions made, to accommodate storm water calculations be provided prior to the issuance of a site or building permit; 9. That a recorded copy of cross drainage agreement addressing water treatment on adjacent property be provided prior to the issuance of a site or building permit; 10. That the site plan be revised to show turning template for a passenger car maneuvering at turns prior to the issuance of a site or building permit; 11. That the site plan show parking spaces comply with City standard dimensions, including angle in degrees used, prior to the issuance of a site or building permit; 12. That the site plan show an accessible path from a building's accessible entrance to a public sidewalk and to multiple buildings on site compliant with Florida Accessibility Code for Building Construction Chapter 11, Section 11-4.3.2, prior to the issuance of a site or building permit; 13. That sight visibility triangles at the driveways be shown on the site and landscape plans, prior to the issuance of a site or building permit; 14. That a copy of the recorded cross-access parking agreement binding upon successive property owners be provided, prior to the issuance of a Certificate of Occupancy, 15. That all site revisions including but not limited to: storm water, landscaping, and tree preservation, required for 1834 Belcher Road be approved and completed, prior to the issuance of a Certificate of Occupancy for 1822 Belcher Road; and 16. That all signage meet Code requirements and be architecturally integrated into the design of the site and buildings. I concur with the findings of the Development Review Committee and, through this letter, approve your application for Flexible Standard Development with above 15 conditions. The approval is based on and must adhere to the application dated received June 17, 2005 and revised site plans and building elevations dated received November 17, 2005. Pursuant to Section 4-303, an application for a, building permit shall be made within one year of Flexible Standard Development approval (December 5, 2006). All required certificates of occupancy shall be obtained within two years of the date of issuance of the building permit. Time frames do not change with successive owners. An extension of time may be granted by the Community Development Coordinator for a period not to exceed one year and only within the original period of validity. The Community Development Coordinator may approve an additional extension of time not to exceed one year for good cause shown and documented in writing. The coordinator must receive the request for this extension within the one-year period of validity after the original time extension. The Community Development Coordinator may approve an additional extension of time not S:IFlanning DepartmentICD BIFlex Standard (FLS)Ilnactive or Finished CasesWelcher Rd N 1822 (C) JYSIFLS2005-06040 Development Order.doc A December 5, 2005 FLS2005-06040 Page 3 to exceed on year for good cause shown and documented in writing. The coordinator must receive the request for this extension within the one-year period of the validity after the original extension. The issuance of this Development Order does not relieve you of the necessity to obtain any building permits or pay any impact fees that may be required. In order to facilitate the issuance of any permit or license affected by this approval, please bring a copy of this letter with you when applying for any permits or licenses that require this prior development approval. If you have any questions, please do not hesitate to call John Schodtler, Planner I at 727-562-4547. Sincerely, Michael elk, Al Planning Director S: (Planning DepartmentlCD BlFlex Standard (FLS)Ilnactive or Finished CaseslBelcher Rd N1822 (C) JYSIFLS2005-06040 Development Order.doc a ? Dec. 08 2005 10:08AM YOUR LOGO YOUR FAX NO. 7275624865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 94474989 Dec.08 10:07AM 01'24 SND 03 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX (435-7329). Land Resource Condition A 0 Conditions Associated With FLS2005-06040 1822 N BELCHER RD Rick Albee 727-562-4741 07/25/2005 7/25/05-Provide a Tree Preservation Plan prepared by a certified arborist, consulting arborist, landscape architect or other specialist in the field of arboriculture. This plan must show how the proposed building, parking, stormwater and utilities impact the critical root zones (drip lines) of trees to be preserved and how you propose to address these impacts ie; crown elevating, building lintels, root pruning and/or root aeration systems. Other data required on this plan must show the trees canopy line, actual tree barricade limits (2/3 of the drip line and/or in the root prune lines if required), and the tree barricade detail. And any other pertinent information the arborist feels relates to tree preservation. Provide prior to building permit. ---?11/30/05-Could not locate plan drawings as indicated. Provide prior to building permit. 07/25/2005 7/25/05-The tree survey in inaccurate, the trees south of the Belcher Rd.entrance drive have been removed without a permit. Show replacements prior to D.O. 11/3/05- The Holly 7 Holly south of the Belcher Rd.entrance drive has been removed. Remove from ALL plans and show a replacement on the Landscape Plan. A second Holly was also removed from this buffer and a replacement shall be shown on the Landscape Plan. Show replacements prior to D.O. ---? 11/30/05- Show the replacement trees in the same location from which they were removed prior to building permit. 07/25/2005 7/25/05-Show to be removed and replaced the three diseased Holly trees. Two flanking the Sunnydale Blvd. entrance drive and the one north of the Belcher Rd. entrance drive (shown as a 5" Oak tree). Provide prior to D.O. 11/3/05-Show to be removed and replaced the three diseased Holly trees. Two flanking the Sunnydale Blvd. entrance drive and the one north of the Belcher Rd. entrance drive. Show to be removed from ALL plans and show the replacements on the Landscape Plan. Provide prior to D.O. --X11/30/05- Show the replacement trees in the same location from which they were removed prior to building permit. Print Date: 12/01/2005 Not Met Not Met Not Met CaseConditons Page 1 of 1 0 } Clearwater FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT 100 S. MYRTLE AVE., 2nd Floor CLEA R WA TER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 TO: G'Eo2GE PAOPA S FAX: LI 4 ,7 ~ y 1 6 FROM: d 4r? <,rkADC-,ff- Phone: DATE: 12- O ! o !?- SUBJECT: / 2 Z r66L,446rLjp l.52-OVS - OG 0 .10 MESSAGE: R =*.AA< a t tJ G NUMBER OF PAGES(INCLUDING THIS PAGE) 0 NO. OTHER FACSIMILE START TIME c w • Dec. 01 2005 03:51PM YOUR LOGO YOUR FAX NO. 7275624865 USAGE TIME MODE PAGES RESULT 01 94474989 Dec.01 03:50PM 00'56 SND 02 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX (435-7329). 94 G.J. Ho ann Professional Engineer vem8fiR4,4 y Blvd., New Port Richey, FL 34654 Phone: 727 844-7686 Fax: (727) 844-7626 Ms. Sherry Watkins City Of Clearwater - Municipal Service Bldg. Planning and development Services, Building & Inspections Division 100 South Myrtle Ave. #210 (2' floor) Clearwater, Florida 33758-4748 Re: Proposed office bldg. Located at 1822 N. Belcher Road, Lot 2 Dear Ms. Watkins: Enclosed are 7 sets of revised plans. The following changes have been made based on comments received: FIRE CONDITION 1. Fire Hydrant is shown on plans LAND RESOURCE CONDITION 1. Tree preservation plan is enclosed 2. Replacement for removed trees now shown on landscape plan J? ORIGINAL RECENED No? 7 2005 PLANNING DEPAR' ERT CITY OF CLEA M 3. Diseased Holly trees shown to be removed and replaced on landscape plan 4. All trees with canopies now shown on proposed grading plan ZONING CONDITION 1. Revised set of building elevations enclosed 2. Drive aisle location adjusted on plans Should you have questions, please contact me. Thank you for your assistance in this matter. Sincerely, Galen J. Ho ann, 4 t. G.J. Ha mann Professional Engineer 8620 Airway Blvd., New Port Richey, FL 34654 October 2005 Ms. Sherry Watkins City Of Clearwater - Municipal Service Bldg. Planning and development Services, Building & Inspections Division 100 South Myrtle Ave. #210 (2' floor) Clearwater, Florida 33758-4748 Re: Proposed office Bldg. Located at 1822 N. Belcher Road, Lot 2 Dear Mr. Perry : Enclosed are 7 sets of revised plans together with: a. Cross easement Agreement b. Drainage Narrative In reply to your questions, the following is provided: General Engineering 1. Sidewalks Now Shown 2. Dumpster Now shown Prior To Building Permit 1. Note added 2. Note added 3. R.O.W. Permit applied for Environmental. Phone: (727) 844-7686 Fax: (727) 844-7626 1. Hydrant added ORIGINAL Fire Dept 1. Understood 2. Emergency 20' wide Drive now shown 3. Turning radius now shown 4. Note added 5. Understood. Sprinkler system will be used 6. Hydrant shown Land Resources 1. Trees to be removed 2. Tree preservation plan enclosed 3. Survey accurately depicted on site plans 4. Survey on site plans now complete 5. Holly trees removal on plan 6. Canapes shown 7. Trees to be removed Landscaping 1. Note removed Stormwater 1. Cross sections added to plans 2 SWEWNID Permit will be forwarded when received /? ? . -" L= k 3. Litoral shelf now shown NUV 0 1 2005 4. Narrative enclosed PLANNING DEPARTMENT CITY OF CLEARWATER 5. Easement enclosed ORIGINAL Traffic 1. Flows reversed 2. Template shown 3. Dimensions now added 4. Curb radii shown 5. Access path shown 6. Sight triangles added 7. Loading space added 8. Note added 9. Sidewalk added 10. Notes added 11. R.O.W. applied for Planning 1-12 see attachment Should you have questions, please contact me. Thank. you for your assistance in this matter. Sincerely, J Galen J. Hofmann, PE 1,jLn! i.NUV 01 1005 t LA WINO DEPARTMENT CITY OF CLEARWATER 0Mt?9NAL PROPOSED OFFICE - DRAINAGE NARRATIVE The existing stormwater system served only the Old Roger's Restaurant site. The proposed stormwater pond has been modified in the following manner to include the proposed office site. a. side sloped changed to 2 to 1 slopes b. control structure modified c. grate inlets and piping added to connect to existing site system d. fence added around pond RECEIVED " 01 2005 PLANNING DEPARTMENT CITY OF CLEARWATER ORIGINAL Planning Responses Case No. FLS2005-06040 1822 N. Belcher Rd. 1. Harmony with scale, bulk, coverage, density and character of adjacent properties. The building proposed is 8,280 square feet in size, consisting of two stories. It is less than the maximum buildable height. Adjacent constructs have features with heights in excess of 20 feet. The two story construction will be within 10 feet of the adjacent structures in overall height. The coverage on the first level is 3,600 square feet, to permit additional ground area for parking. The adjacent properties consist of bank, restaurant, and office/warehouse uses. The proposed office is consistent with the character of adjacent properties in that all but the restaurant contain similar uses, in that they all contain offices. 2. How will office use not discourage or hinder appropriate development and use of adjacent land and buildings or significantly impair the value thereof? The office use is consistent with the land use, and has no negative impact on adjacent land or buildings, and will not impair the value of those properties. The adjacent restaurant site will be impacted through common use of driveways and retention, however, will be improved during construction to improve/increase retention and will further benefit from cross parking rights on the office site. 3. How will the office use not adversely affect the health or safety or persons residing or working in the neighborhood? There are no persons residing in the neighborhood. The office project will not create any odors or hazardous emissions and will have minimal adverse impact on the health or safety of persons working in the area. The property will improve public access in that sidewalks will be installed to permit pedestrian traffic along the West side of N. Belcher. 4. How is the office use designed to minimize traffic congestion? The office utilizes existing curb cuts that service the adjoining restaurant, and keeps traffic flow contained within the office and restaurant site. The flow is directed around the proposed office in a one-way flow to minimize hazards and congestion to get around the structure. Parking is evenly placed at the rear and front of the office to avoid parking congestion. The office shall benefit from an easement for ingress/egress over the adjoining restaurant site which aids traffic flow around office site. How is the office use consistent with the community character of the immediate vicinity? : C ( 31=D NO of zoosORIGINAL PLANNING DEPARTMENT CITY OF CLFAPMfATFR The office use is consistent with the land use and zoning for both Clearwater and County use. 6. How does the office use minimize adverse effects, including visual, acoustic, olfactory, and hours of operation impacts, on adjacent properties? The office use doesn't adversely affect the adjacent property visually as the office use is the cleanest use for the site. Solid waste is minimal, and traffic is minimal and typically vehicular (not truck traffic). Acoustically, there are no sounds that would emanate from the office, except for external mechanical units servicing the structure which would be minimal. There are no odorous emissions anticipated from the proposed office. Waste would be clean, non-odorous (primarily paper) solid waste. The proposed use anticipates office hours of operation primarily weekdays between 8 AM to 6 PM, which is complimentary to the hours of operation of the adjacent restaurant which has higher use at evening and weekend hours. All other adjacent properties would be minimally impacted by the proposed office hours of operation, except to the increase in trips. 7. How is Flexibility Criteria being met: (building height) vs. site plan. Also, address roof deck/parapet height-altered roof. The proposed office will use a gable type roof, not parapet as originally proposed. The overall building height is expected to be approximately 25'-28'. 8. How does side setback meet Flexible Criteria-emergency vehicle access. Emergency vehicles will have access to the entire perimeter of the proposed building, on three sides from within the building site, and on the fourth side (North side) from the adjoining restaurant site which is used for shared parking and driveways. 9. How side setback Flexibility Criteria being met. Reduction in side rear setback- parking and design issues. The parking and drive lanes have been designed to spread the parking between the front and rear of the parcel, and to keep the traffic flow one direction around the proposed structure. This will maximize the green space on the Belcher and Sunnydale right of way sides which will permit enhanced aesthetics through larger greenbelts and planting areas. There is a buffer between the North and West boundary lines of the office and restaurant site which is consistent with the typical parking islands on the restaurant site. 10. How side setback Flexibility Criteria being met-reduction of side and rear setback does not reduce the amount of landscape area otherwise required. See No. 9 above. RN17ZC E ???D "UV ol'SRIGINAL PLANNING DEPARTMENT CITY OF CLEARWATER 11. Estimated project value for the development. The estimated project value for the development including lot and improvements is $950,000.00. 12. Proposed signage-location of signs and integration with landscaping plan. The proposed sign at the corner of N. Belcher and Sunnydale will not interfere with any landscaping, as none exists presently on the site. All new plantings will be around the proposed pylon sign and will enhance the site. LD NUV 01 2005 PLANNING DEPARTMENT CITY OF CLEARWATER ORIGINAL VJ 9, Fire Condition s • Conditions Associated MAP FLS2005-06040 1822 N BELCHER RD James Keller 562-4327 x3062 07/29/2005 Provide and show on the site plan a fire hydrant within 300 feet. Please acknowledge intent to Not Met comply PRIOR TO D.O. Land Resource Condition Rick Albee 727-562-4741 07/25/2005 Provide a Tree Preservation Plan prepared by a certified arborist, consulting arborist, landscape Not Met architect or other specialist in the field of arboriculture. This plan must show how the proposed building, parking, stormwater and utilities impact the critical root zones (drip lines) of trees to be preserved and how you propose to address these impacts ie; crown elevating, building lintels, root pruning and/or root aeration systems. Other data required on this plan must show the trees canopy line, actual tree barricade limits (2/3 of the drip line and/or in the root prune lines if required), and the tree barricade detail. And any other pertinent information the arborist feels relates to tree preservation. Provide prior to building permit. 07/25/2005 7/25/05-The tree survey in inaccurate, the trees south of the Belcher Rd.entrance drive have been Not Met removed without a permit. Show replacements prior to D.O. 11/3/05- The Holly 7" Holly south of the Belcher Rd.entrance drive has been removed. Remove from ALL plans and show a replacement on the Landscape Plan. A second Holly was also removed from this buffer and a replacement shall be shown on the Landscape Plan. Show replacements prior to D.O. 07/25/2005 7/25/05-Show to be removed and replaced the three diseased Holly trees. Two flanking the Not Met Sunnydale Blvd. entrance drive and the one north of the Belcher Rd. entrance drive (shown as a 5" Oak tree). Provide prior to D.O. 11/3/05-Show to be removed and replaced the three diseased Holly trees. Two flanking the Sunnydale Blvd. entrance drive and the one north of the Belcher Rd. entrance drive. Show to be removed from ALL plans and show the replacements on the Landscape Plan. Provide prior to D.O. 07/25/2005 7/25/05-Show ALL of the trees with their canopies on ALL civil and landscape plans prior to D.O. Not Met 11/3/05-Show all or the trees to be preserved, with their canopies, on the Proposed Grading plan prior to D.O. Zoning Condition John Schodtler 727-562-4547 07/08/2005 Provide a revised set of building elevations (dimensioned) showing the new roof design. 07/08/05 Not Met Address how Flexibility Criteria is being met: (Building Height) The increased height results in an improved site plan, landscaping area in excess of the minimum required or improved design and appearance. Code provisions provide for parapet walls to be no more than 30" inches above the top of roof deck for a flat roof. Proposal includes a parapet of 8.foot, 10 inches above the top of the roof deck. Provide the justification for such an increase. 11/08/2005 Revise. The drive aisle along sunnydale to meet a 15 foot setback (add three feet between the Not Met property line and the drive aisle and subtract three feet from the distance from the building and the drive aisle). Does not look like it will cause any problems with parking, landscaping, or fire's drive aisle requirements. Print Date: 11/08/2005 CaseConditons Page 1 of 2 MYKILC 36 S t 5L` ? c.Tv. Llt . w v ?'/ EOCE 1F, AS>'B t FX K ! ; / 'R A8fshry LT -?? y ?, EX. GRAPE 4 i fD.QE OF' L 3 MYKTL.E Y ?•a y ?` i ? tl_/ ? 1. _ PE jJ?r: f sr 9' .4?.5?- ?` fr I ,'?QO ti Ex, OLL 46" CRAPE: °A , x .; ., ` IMY?TLE i ' 3" PROQbSE[1'C NCf?T ;'SE154IOR To )Y5k6fi , r4 ' .? /! ,'/ /. ''' . '//;' /. i i % / / is ' .• /. / / % 'i ?/? ji, /x /Z 7,10 IDE Arils y"' /"... ?' /.% /i"• , ?/ .!i'// it •'/ ' %' i !' /? i' j /: ! ! r/! !..- / ?/ / !/ /? //' ,'/ ' i j%. s so'i ?(Pl ?9 .oa' / I 60.00' ! .& -3, 1 ...... 1 ! w FIRST FLOOR = 3,600 S.F. oz 3 i OC . ' ` SECOND FLOOR = 4,680 S.F. I r ° TOTAL AREA = 8,280 S.F. b I i OFFICE BUILDING ' F. F. - 53.10' e ! s r„ Z l I 01-29-15-55950-000-0020 a ' ONE ?A ONE WAa---------------'?-- 0 ° WAY ER,.CI. 3? WAY' 10' VS BUFFER LINE 94 08,(P&M) 6 'N t .4.0.'d SIDEWALK' - - - - - - - - - - - - - - - - - - - - -- 4 - SANITARY 2' CONCRETE VALLEY CURB APPROXIMATE SIGNAGE LOCATION. r ALL SIGNAGE TO BE IN CONFORMANCE O'C oZ WITH THE CITY OF CLEARWATER REGULATIONS. NO SIGNAGE TO BE INSTALLED WITHOUT Clearwater FAX COVER MEMO CITY OF CLEARWATER PLANNING DEPARTMENT 100 S. MYRTLE AVE., 2nd Floor CLEARWATER, FL 33756 (727) 562-4567 FAX: (727) 562-4865 TO: GEo2.GC G' PAPP 4S FAX: 4q7- q of b9 Phone: FROM: 10 H c.?l OraTtrE K Phone: DATE: !! o 8 0 5 SUBJECT: FL.s Zo o 5- o (-o 4 u f 8z? N3E?E4?i2 MESSAGE: U P DAIS=-, GpM M6 NT S NUMBER OF PAGES(INCLUDING THIS PAGE) 15 Nov. 08 2005 02:21PM YOUR LOGO CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 94474989 Nov.08 02:19PM 01'48 SND 03 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-FE LP-FAX C435-7329). CITY OF CLEARWATER DEVELOPMENT SERVICES DEPARTMENT Post Office Box 4748, Clearwater, Florida 33758-4748 Municipal Services Building, 100 South Myrtle Avenue, Clearwater, Florida 33756 Telephone (727) 5624567 Fax (727) 562-4576 October 25, 2005 GEORGE G PAPAS, ATTORNEY 901 N HERCULES AVE STE C CLEARWATER, FL 33765 RE: FLS2005-06040 (LOCATED AT 1822 N BELCHER RD) Dear Owner/Representative: There has been no activity with regards to your application, under case number (FLS2005-06040) in the last thirty (30) days. Please find attached comments related to this case that are still outstanding. Please contact our office with the status of your resubmittal prior to November 1, 2005. Please contact Sherry Watkins at 727-562-4582 should you have any questions. Thank you for your assistance in this matter. Sincerely, John Schodder, Planner I Cc: File C:\Documents and Settings\john.schodtler\Desktop\30DayLtrPing.rpt :0- s Engineering Condition .Conditions Associated With FLS2005-06040 1822 N BELCHER RD Steve Doherty 07/19/2005 1. Show sidewalk(s) to be installed within all right-of-way(s) adjacent to this site per City's Not Met Standards and Specifications. Sidewalks must be installed prior to issuance of a C.O. per Community Development Code Section 3-1701. (4-foot wide on Sunnydale Street and 5-foot wide on Belcher Road). 2. How is solid waste to be handled? All of the above prior to CDB. Prior to building permit: 1. A sewer lateral constructed in accordance with City of Clearwater Contract Specifications and Standards Index # 305 shall be installed at developer's cost. 2. The City of Clearwater will provide water tap, set the water meter and a B.F.P.D. (back flow preventor device) if applicable. Applicant is responsible for all associated fees and all other installation fees. 3. Please note, a Pinellas County right-of-way permit is required for all work taking place in Belcher Road right-of-way. FIRE CONDITON 07/19/2005 07/22/2005 Fire Condition General Note: DRC review is a prerequisite for Building Permit Review, additional comments may be forthcoming upon submittal of a Building Permit Application. Ann Downes-Blackburn 562-4327xt3025 Provide and show on the site plan a fire hydrant within 300 ft. Please acknowledge intent to comply PRIOR TO D.O. No Issues Ann Downes-Blackburn 562-4327xt3025 Not Met Not Met 07/19/2005 ***PLEASE NOTE*** REVIEW AND APPROVAL BY THE AUTHORITY HAVING JURISDICTION Not Met SHALL NOT RELEIVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE 2004 EDITION. This DRC review by Fire is not an approval or review of any construction plans or documents other than site work. Please acknowledge PRIOR TO D.O. 07/19/2005 Provide and show on the site plan 24 ft wide driveway and drive aisles for emergency vehicle Not Met ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 07/19/2005 Provide and show on the site plan minimum 30 degree turning radii for emergency vehicle Not Met ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 07/19/2005 All grates and drain covers in drive aisles must meet HS-20 specifications, to support live loads of Not Met 80,000 lb. emergency vehicles. Please acknowledge intent to comply PRIOR TO D.O. 07/19/2005 Depending on type of construction used in the building, a fire sprinkler system may be required to Not Met accommodate ground level parking of vehicles under second story overhang. Please acknowledge intent to comply PRIOR TO D.O. 07/29/2005 Provide and show on the site plan a fire hydrant within 300 feet. Please acknowledge intent to Not Met comply PRIOR TO D.O. Landscape John Schodtler 562-4773 727-562-4547 07/29/2005 Clarify. There is a note on the landscape plans indicating there "NORTH: 5' WIDE BUFFER, 1 Not Met TREE 360.C., 100% SHRUBS." The site plan indicates there is only 3 feet between the building and the property line. Land Resource Condition Rick Albee 727-562-4741 Print Date: 10/25/2005 CaseConditons Page 1 of 4 r: FLS2005-06040 1822 N BELCHER RD • Land Resource Condition Rick Albee 727-562-4741 07/25/2005 The proposed building and stormwater extension is too close to the Oak trees north of the Not Met proposed building. Either reroute the storm line and relocate the building or remove the trees. If this is unobtainable the trees will need to be removed and replaced on the property on which they were removed at an inch for inch ratio or payment in lieu of replacement at $48 per inch. Resolve prior to D.O. 07/25/2005 Provide a Tree Preservation Plan prepared by a certified arborist, consulting arborist, landscape Not Met architect or other specialist in the field of arboriculture. This plan must show how the proposed building, parking, stormwater and utilities impact the critical root zones (drip lines) of trees to be preserved and how you propose to address these impacts ie; crown elevating, building lintels, root pruning and/or root aeration systems. Other data required on this plan must show the trees canopy line, actual tree barricade limits (2/3 of the drip line and/or in the root prune lines if required), and the tree barricade detail. And any other pertinent information the arborist feels relates to tree preservation. Provide prior to building permit. 07/25/2005 The tree survey in inaccurate, the trees south of the Belcher Rd.entrance drive have been Not Met removed without a permit. Show replacements prior to D.O. 07/25/2005 The tree survey in incomplete, show the existing Creape Myrtle trees in the existing landscape Not Met islands prior to D.O. 07/25/2005 Show to be removed and replaced the three diseased Holly trees. Two flanking the Sunnydale Not Met Blvd. entrance drive and the one north of the Belcher Rd. entrance drive (shown as a 5" Oak tree). Provide prior to D.O. 07/25/2005 Show ALL of the trees with their canopies on ALL civil and landscape plans prior to D.O. Not Met 07/25/2005 The proposed "Top of Bank" is too close to all of the existing Oak trees. The existing grade shall be left undisturbed at least 7 feet away from each tree. Recommend utilizing the 15' landscape buffer for to obtain the additional retention volume. Resolve prior to D.O. Parks S Recs Condition No issues - office building on less than one acre Storm Water Condition Jason Kinney 562-2604 07/1812005 Prior to building permit the following items to be addressed: 1. Provide cross-sections at property lines, show no adverse impacts. 2. Provide SWFWMD Modification of Permit 3. Provide a 35% Littoral Zone concentrated near the pond outfall. 4. Provide a written narrative to accommodate calculations. Narrative should include discussion on methodology, history, hydrology, hydraulics and basis for all assumptions made. 5. Provide recorded copy of cross drainage agreement to address water treatment on adjacent property. Traffic Eng Condition Bennett Elbo 562-4775 Not Met Not Met Not Met 07/15/2005 Reverse the one-way flow and angle parking thereby eliminating 3-way stop. Not Met 2. Show turning template for a passenger car maneuvering at turns. 3. Show dimensions for angled parking spaces including angle in degrees used. Angled parking must comply with City standard dimensions. 4. Provide curb radius and driveway width compliant with the City's Fire Department requirements. 5. Provide an accessible path from a building's accessible entrance to a public sidewalk and to multiple buildings on site compliant with Florida Accessibility Code for Building Construction Chapter 11, Section 11-4.3.2. Print Date: 10/25/2005 CaseConditons Page 2 of 4 FLS2005-06040 1822 N BELCHER RD Traffic Eng Condition Bennett Elbo 562-4775 6.Show 20'x 20' sight visibility triangles at the driveways. (City's Community Development Code, Section 3-904). 7. Provide a 12'x 35' loading space per City's Community Development Code, Section 3-1406 B.1.. 8. Overhang must be a minimum of 8'2" vertical clear to accommodate H/C van. 9. Provide sidewalk(s) along the property's frontage on SunnyDale Boulevard and Belcher Road. (Development Code Sections 3-1701 and 3-1907 and Clearwater Contract Specifications and Standards, Article 30) 10. All substandard sidewalks and sidewalk ramps adjacent to or a part of the project must be upgraded to City standards, including A.D.A. 11. Obtain an approved right-of-way permit from Pinellas County for any work in a county right-of-way required prior to issuance of a building permit. All of the above to be addressed prior to a D.O.. Prior to C.O.: 1. Applicant needs to provide a copy of the recorded cross-access parking agreement binding upon successive property owners. General note: Transportation Impact Fee of 10,150 sq.ft. x ($3,292/1,000 sq.ft.) =$33,413.80 to be paid priort o a C.O.. General Applicability Criteria #1 John Schodtler 07/08/2005 Clarify. How is the office use in harmony with the scale, bulk, coverage, density, and character of adjacent properties? Reply to each seperately. General Applicability Criteria #2 John Schodtler 07/08/2005 Clarify. How will the office use not discourage or hinder the appropriate development and use of adjacent land and buildings or significantly impair the value thereof? General Applicability Criteria #3 John Schodtler 07/08/2005 Clarify. How will the office use not adversely affect the health or safety or persons residing or working in the neighborhood? General Applicability Criteria #4 John Schodtler 727-562-4547 07/08/2005 Clarify. How is the office use designed to minimize traffic congestion? General Applicability Criteria #5 John Schodtler 727-562-4547 07/08/2005 Clarify. How is the office use consistent with the community character of the immediate vicinity? General Applicability Criteria #6 John Schodtler 727-562-4547 727-562-4547 727-562-4547 727-562-4547 Not Met Not Met Not Met Not Met Not Met 07/08/2005 Clarify. How does the office use minimize adverse effects, including visual, acoustic, olfactory, and hours of operation impacts, on adjacent properties? Reply to each seperately. Zoning Condition John Schodtler 727-562-4547 07/08/2005 Address how Flexibility Criteria is being met: (Building Height) The increased height results in an improved site plan, landscaping area in excess of the minimum required or improved design and Not Met Not Met CaseConditons Print Date: 10/25/2005 Page 3 of 4 FLS2005-06040 1822 N BELCHER RD Zoning Condition John Schodtler 727-562-4547 appearance. Code provisions provide for parapet walls to be no more than 30" inches above the top of roof deck for a flat roof. Proposal includes a parapet of 8 foot, 10 inches above the top of the roof deck. Provide the justification for such an increase. 07/08/2005 Address how the side setback Flexibility Criteria are being met: The reduction in side and rear Not Met setback does not prevent access to the rear of any building by emergency vehicles; 07/08/2005 Address how the side setback Flexibility Criteria are being met: The reduction in side and rear Not Met setback results in an improved site plan, more efficient parking or improved design and appearance. 07/08/2005 Address how the side setback Flexibility Criteria are being met: The reduction in side and rear Not Met setback does not reduce the amount of landscaped area otherwise required. .07/26/2005 Provide an estimated project value for this development. Not Met 07/29/2005 Is signage to be proposed? The location of freestanding signs can often cause conflict with Not Met landscape plans. Print Date: 10/25/2005 CaseConditons Page 4 of 4 Tram i ss i on- Report Date/Time 10-2S-OS;12:06PM Local ID 7275624796 Local Name Company Logo This document was confirmed. (reduced sample and details below) Document Size Letter-S CITY OF CLEARWATER DEVELOPMENT SERVICES DEPARTMENT Post Office Boa 4748, Clearwater, Florida 33758-4748 GO Municipal Services BuildirW, 100 Sonth Myrtle Avenue, Clearwater, Florida 33756 Telephoae(727)562.4567 Pax(727)5624576 October 25, 2005 GEORGEG PAPAS, ATTORNEY 901 NHERCUIESAVE STEC CLEARWATER, FL 33765 RE: FMO05-06040 (LOCATED AT 1822 N BEI.CFDTR RD) Deer ownedRepresentative: There bas been nn activity with regards to y= application, under case number (FL.92005-06940) in the last thirty (30) days. Please find attached comments related to this case that are still outstanding. Please contactour office with the stains of yourresubmitted priorto November 1, 2005. Please contact SherryWadkins at 727-562-4582 should you have any questions. Thank you for your asaittance in this matter. Sincerely, John Schodtler, Planner I Cc: File C:1Doeem cnts and settingayohn.srJiodaee?nesklap?loDaYl trPlag.rpt Total Pages Scanned : 5 Total Pages Confirmed : 5 No. DOC Remote Station Start Time Duration Pages Mode Comments Results 1 2 34 34 94474989 94474989 10-25-05;12:02PM 12:OSPM 49 1'15 1/ 5 S/ 5 EC EC R 0513 26.4 CP 24.0 Notes . EC: Error Correct RE: Resend PD: Polled by Remote MB: Receive to Mailbox BC: Broadcast Send MP: Multi-Poll PG: Polling a Remote PI: Power Interruption CP: Completed RM: Receive to Memory DR: Documen t Removed TM: Terminated by user HS: Host Scan HP: Host Print FO: Forced Output WT: Waiting Transfer HF: Host Fax HR: Host Receive FM: Forward Mailbox Doc. WS: Waiting Send 0 0 CITY OF CLEARWATER PLANNING DEPARTMENT Post Office Box 4748, Clearwater, Florida 337584748 Municipal Services Building, 100 South Myrtle Avenue, Clearwater, Florida 33756 Telephone (727) 562-4567 Fax (727) 562-4576 August 02, 2005 PAPAS, ATTORNEY, GEORGE 901 N HERCULES AVE STE C CLEARWATER FL 33765 RE: FLS2005-06040 LOCATED AT 1822 N BELCHER RD - PAPPAS & SONS Dear GEORGE PAPAS, ATTORNEY: The following are comments generated at the City's Pre-Development Review Committee (PRE-DRC) meeting regarding your case number: FLS2005-06040. These comments are generated early to give you assistance in preparing responses to the comments for the upcoming DRC Meeting on August 4, 2005. Please be prepared to address these comments and any others that may be generated at the DRC meeting. Resubmittals will not be accepted at the meeting, please make arrangements to resubmit to Sherry Watkins after the DRC meeting. If you have any questions about times or location, please contact Sherry Watkins, at 727-562-4582. Sincere , 7 Jo TSchodtler Planner I Cc: File 11:00 am • Case Number: FLS2005-060 1822 N BELCHER RD r Owner(s): George G Papas, Attorney 901 N Hercules Ave Ste C Clearwater, FI 33765 TELEPHONE: 727-447-4999, FAX: 727-447-4989, E-MAIL: No Email Applicant Papas & Sons, Llc 2632 Velventos Drive Clearwater, F] 33761 TELEPHONE: 727-787-6146, FAX: No Fax, E-MAIL: No Email Location: 0.499 acres located at the northwest corner of the intersection of Belcher Road and Sunnydale Blvd. Atlas Page: 262B Zoning District: IRT, Industrial, Research and Technology Request: Flexible Standard Development approval to construct a 10,150 square foot, two-story office building. The request includes an increase to the maximum building height from 25 feet to 36.5 feet, a side (north) setback reduction from 10 feet to three feet (to building), a side (north) setback reduction from 10 feet to zero feet (to pavement), a side (west) setback reduction from 10 feet to zero feet (to pavement), a front (east setback reduction from 25 feet to 20 feet (to pavement), and a front (south) setback reduction from 25 feet to 20 feet (to pavement), per Section 2-703.1. Proposed Use: Offices Neighborhood Clearwater Neighborhoods Coalition Association(s): Clearwater, F] 33761 2544 Frisco Drive TELEPHONE: 727-725-3345, FAX: No Fax, E-MAIL: Djw@gte.net Presenter: John Schodtler, Planner I Attendees Included: The DRC reviewed this application with the following comments: General Engineering: 1 . 1. Show sidewalk(s) to be installed within all right-of-way(s) adjacent to this site per City's Standards and Specifications. Sidewalks must be installed prior to issuance of a C.O. per Community Development Code Section 3-1701. (4-foot wide on Sunnydale Street and 5-foot wide on Belcher Road). 2. How is solid waste to be handled? All of the above prior to CDB. Prior to building permit: 1. A sewer lateral constructed in accordance with City of Clearwater Contract Specifications and Standards Index # 305 shall be installed at developer's cost. 2. The City of Clearwater will provide water tap, set the water meter and a B.F.P.D. (back flow preventor device) if applicable. Applicant is responsible for all associated fees and all other installation fees. 3. Please note, a Pinellas County right-of-way permit is required for all work taking place in Belcher Road right-of-way. General Note: DRC review is a prerequisite for Building Permit Review, additional comments may be forthcoming upon submittal of a Building Permit Application. Environmental: 1 . Provide and show on the site plan a fire hydrant within 300 ft. Please acknowledge intent to comply PRIOR TO D.O. 2. No Issues Fire: Development Review Agenda - Thursday, August 4, 2005 - Page 23 • 1 , ***PLEASE NO#** REVIEW AND APPROVAL BY THE AUTHORITY HAVING JURISDICTION SHALL NOT RECEIVE 1 HE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE 2004 EDITION. This DRC review by Fire is not an approval or review of any construction plans or documents other than site work. Please acknowledge PRIOR TO D.O. 2. Provide and show on the site plan 24 ft wide driveway and drive aisles for emergency vehicle ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 3 . Provide and show on the site plan minimum 30 degree turning radii for emergency vehicle ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 4. All grates and drain covers in drive aisles must meet HS-20 specifications, to support live loads of 80,000 lb. emergency vehicles. Please acknowledge intent to comply PRIOR TO D.O. 5. Depending on type of construction used in the building, a fire sprinkler system may be required to accommodate ground level parking of vehicles under second story overhang. Please acknowledge intent to comply PRIOR TO D.O. 6. Provide and show on the site plan a fire hydrant within 300 feet. Please acknowledge intent to comply PRIOR TO D.O. Harbor Master: No Comments Legal: No Comments Land Resources: 1 . The proposed building and stormwater extension is too close to the Oak trees north of the proposed building. Either reroute the storm line and relocate the building or remove the trees. If this is unobtainable the trees will need to be removed and replaced on the property on which they were removed at an inch for inch ratio or payment in lieu of replacement at $48 per inch. Resolve prior to D.O. 2. Provide a Tree Preservation Plan prepared by a certified arborist, consulting arborist, landscape architect or other specialist in the field of arboriculture. This plan must show how the proposed building, parking, stormwater and utilities impact the critical root zones (drip lines) of trees to be preserved and how you propose to address these impacts ie; crown elevating, building lintels, root pruning and/or root aeration systems. Other data required on this plan must show the trees canopy line, actual tree barricade limits (2/3 of the drip line and/or in the root prune lines if required), and the tree barricade detail. And any other pertinent information the arborist feels relates to tree preservation. Provide prior to building permit. 3 . The tree survey in inaccurate, the trees south of the Belcher Rd.entrance drive have been removed without a permit. Show replacements prior to D.O. 4. The tree survey in incomplete, show the existing Creape Myrtle trees in the existing landscape islands prior to D.O. 5 , Show to be removed and replaced the three diseased Holly trees. Two flanking the Sunnydale Blvd. entrance drive and the one north of the Belcher Rd. entrance drive (shown as a 5" Oak tree). Provide prior to D.O. 6. Show ALL of the trees with their canopies on ALL civil and landscape plans prior to D.O. 7. The proposed "Top of Bank" is too close to all of the existing Oak trees. The existing grade shall be left undisturbed at least 7 feet away from each tree. Recommend utilizing the 15' landscape buffer for to obtain the additional retention volume. Resolve prior to D.O. Landscaping: 1 . Clarify. There is a note on the landscape plans indicating there "NORTH: 5' WIDE BUFFER, 1 TREE 35' O.C., 1.00% SHRUBS." The site plan indicates there is only 3 feet between the building and the property line. Parks and Recreation: 1 . No issues - office building on less than one acre Stormwater: 1 , Prior to building permit the following items to be addressed: 1. Provide cross-sections at property lines, show no adverse impacts. 2. Provide SWFWMD Modification of Permit 3. Provide a 35% Littoral Zone concentrated near the pond outfall. 4. Provide a written narrative to accommodate calculations. Narrative should include discussion on methodology, history, hydrology, hydraulics and basis for all assumptions made. 5. Provide recorded copy of cross drainage agreement to address water treatment on adjacent property. Development Review Agenda - Thursday, August 4, 2005 - Page 24 Solid Waste: • No Comments Traffic Engineering: 1 . Reverse the one-way flow and angle parking thereby eliminating 3-way stop. 2. Show turning template for a passenger car maneuvering at turns. 3. Show dimensions for angled parking spaces including angle in degrees used. Angled parking must comply with City standard dimensions. 4. Provide curb radius and driveway width compliant with the City's Fire Department requirements. 5. Provide an accessible path from a building's accessible entrance to a public sidewalk and to multiple buildings on site compliant with Florida Accessibility Code for Building Construction Chapter 11, Section 1] -4.3.2. 6.Show 20'x 20' sight visibility triangles at the driveways. (City's Community Development Code, Section 3-904). 7. Provide a 12'x 35' loading space per City's Community Development Code, Section 3-1406 B.1.. 8. Overhang must be a minimum of 8'2" vertical clear to accommodate H/C van. 9. Provide sidewalk(s) along the property's frontage on SunnyDale Boulevard and Belcher Road. (Development Code Sections 3-1701 and 3-1907 and Clearwater Contract Specifications and Standards, Article 30) 10. All substandard sidewalks and sidewalk ramps adjacent to or a part of the project must be upgraded to City standards, including A.D.A. 11. Obtain an approved right-of-way permit from Pinellas County for any work in a county right-of-way required prior to issuance of a building permit. All of the above to be addressed prior to a D.O.. Prior to C.O.: 1. Applicant needs to provide a copy of the recorded cross-access parking agreement binding upon successive property owners. General note: Transportation Impact Fee of 10,150 sq.ft. x ($3,292/1,000 sq.ft.) _ $33,413.80 to be paid priort o a C.O.. Planning: 1 . Clarify. How is the office use in harmony with the scale, bulk, coverage, density, and character of adjacent properties? Reply to each seperately. 2. Clarify. How will the office use not discourage or hinder the appropriate development and use of adjacent land and buildings or significantly impair the value thereofl 3 . Clarify. How will the office use not adversely affect the health or safety or persons residing or working in the neighborhood? 4. Clarify. How is the office use designed to minimize traffic congestion? 5 . Clarify. How is the office use consistent with the community character of the immediate vicinity? 6. Clarify. How does the office use minimize adverse effects, including visual, acoustic, olfactory, and hours of operation impacts, on adjacent properties? Reply to each seperately. 7. Address how Flexibility Criteria is being met: (Building Height) The increased height results in an improved site plan, landscaping area in excess of the minimum required or improved design and appearance. Code provisions provide for parapet walls to be no more than 30" inches above the top of roof deck for a flat roof. Proposal includes a parapet of 8 foot, 10 inches above the top of the roof deck. Provide the justification for such an increase. 8 . Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback does not prevent access to the rear of any building by emergency vehicles; 9. Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback results in an improved site plan, more efficient parking or improved design and appearance. 10. Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback does not reduce the amount of landscaped area otherwise required. 11 . Provide an estimated project value for this development. 12. Is signage to be proposed? The location of freestanding signs can often cause conflict with landscape plans. Development Review Agenda - Thursday, August 4, 2005 - Page 25 Other: fir/ No Comments Notes: Insufficient. Please address comments and resubmit seven sets of revisions to Sherry Watlkins, Administrative Analyst, Planning Department (562-4582) Development Review Agenda - Thursday, August 4, 2005 - Page 26 4H-1- L+g 8 g wr V Aug. 02 2005 10:38AM YOUR LOGO : CityOFClearwater-Plan Dept YOUR FAX NO. : 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 94474989 Aug.02 10:36AN 01'56 SND 05 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX (435-7329). ?S ,' . _% 0 Case Number: FLS2005-06040 -- 1822 N BELCHER RD Owner(s): George G Papas, Attorney 901 N Hercules Ave Ste C Clearwater, Fl 33765 TELEPHONE: 727-447-4999, FAX: 727-447-4989, E-MAIL: No Email Applicant Papas & Sons, Llc 2632 Velventos Drive Clearwater, Fl 33761 TELEPHONE: 727-787-6146, FAX: No Fax, E-MAIL: No Email Location: 0.499 acres located at the northwest corner of the intersection of Belcher Road and Sunnydale Blvd. Atlas Page: 262 o Zoning District;.IRT, Industrial, Research and Technology Request: Flexible Standard Development approval to construct a 10,150 square foot, two-story office building. The request includes an increase to the maximum building height from 25 feet to 36.5 feet, a side (north) setback reduction from 10 feet to three feet (to building), a side (north) setback reduction from 10 feet to zero feet (to pavement), a side (west) setback reduction from 10 feet to zero feet (to pavement), a front (east setback reduction from 25 feet to 20 feet (to pavement), and a front (south) setback reduction from 25 feet to 20 feet (to pavement), per Section 2-703.I. Proposed Use: Offices Neighborhood Clearwater Neighborhoods Coalition Association(s): Clearwater, Fl 33761 2544 Frisco Drive TELEPHONE: 727-725-3345, FAX: No Fax, E-MAIL: Djw@gte.net Presenter: John Schodtler, Planner I Attendees Included: The DRC reviewed this application with the following comments: General Engineering: 1 . 1. Show sidewalk(s) to be installed within all right-of-way(s) adjacent to this site per City's Standards and Specifications. Sidewalks must be installed prior to issuance of a C.O. per Community Development Code Section 3-1701. (4-foot wide on Sunnydale Street and 5-foot wide on Belcher Road). 2. How is solid waste to be handled? All of the above prior to CDB. Prior to building permit: 1. A sewer lateral constructed in accordance with City of Clearwater Contract Specifications and Standards Index # 305 shall be installed at developer's cost. 2. The City of Clearwater will provide water tap, set the water meter and a B.F.P.D. (back flow preventor device) if applicable. Applicant is responsible for all associated fees and all other installation fees. 3. Please note, a Pinellas County right-of-way permit is required for all work taking place in Belcher Road right-of-way. General Note: DRC review is a prerequisite for Building Permit Review, additional comments may be forthcoming upon submittal of a Building Permit Application. Environmental: l , Provide and show on the site plan a fire hydrant within 300 ft. Please acknowledge intent to comply PRIOR TO D.O. 2. No Issues Fire: e^ oa ni ??p -1-to '? '??2?Lk PG. ?.IQlrCJ1?lAT10/?5L (3?pwpitg Op LoAC?.?a Zov??6 lot?6A ?, J SS uGS tAn -ru PA-Da ?xl ?. ool?- G61 u,3f?Yt? Development Review Agenda - Thursday, August 4, 2005 - Page 29 -. • • I . ***PLEASE NOTE*** REVIEW AND APPROVAL BY THE AUTHORITY HAVING JURISDICTION SHALL NOT RELEIVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE 2004 EDITION. This DRC review by Fire is not an approval or review of any construction plans or documents other than site work. Please acknowledge PRIOR TO D.O. 2. Provide and show on the site plan 24 ft wide driveway and drive aisles for emergency vehicle ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 3 . Provide and show on the site plan minimum 30 degree turning radii for emergency vehicle ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 4. All grates and drain covers in drive aisles must meet HS-20 specifications, to support live loads of 80,000 lb. emergency vehicles. Please acknowledge intent to comply PRIOR TO D.O. 5 . Depending on type of construction used in the building, a fire sprinkler system may be required to accommodate ground level parking of vehicles under second story overhang. Please acknowledge intent to comply PRIOR TO D.O. Harbor Master: No Comments Legal: No Comments Land Resources: I . The tree survey in inaccurate, the trees south of the Belcher Rd.entrance drive and east of the Sunnydale Blvd entrance drive have been removed without permits. Show replacements prior to D.O. 2. The tree survey in inaccurate, show the existing Creape Myrtle trees in the existing landscape islands prior to D.O. 3 . Show to be removed and replaced the three diseased Holly trees. Two flanking the Sunnydale Blvd. entrance drive and the one north of the Belcher Rd. entrance drive (shown as a 5" Oak tree). Provide prior to D.O. 4. Show ALL of the trees with their canopies on ALL civil and landscape plans prior to D.O. 5. 6. The proposed "Top of Bank" is too close to all of the existing Oak trees. The existing grade shall be left undisturbed at least 7 feet away from each tree. If this is unobtainable the trees will need to be removed and replaced on an inch for inch ratio or payment in lieu of replacement at $48 per inch. Recommend utilizing the 15' landscape buffer for additional retention volume. Resolve prior to D.O. 7. The proposed building and stormwater extension is too close to the Oak trees north of the proposed building. Either reroute the storm line and relocate the building or remove the tree. If this is unobtainable the trees will need to be removed and replaced on an inch for inch ratio or payment in lieu of replacement at $48 per inch. Resolve prior to D.O. 8 . Provide a Tree Preservation Plan prepared by a certified arborist, consulting arborist, landscape architect or other specialist in the field of arboriculture. This plan must show how the proposed building, parking, stormwater and utilities impact the critical root zones (drip lines) of trees to be preserved and how you propose to address these impacts ie; crown elevating, building lintels, root pruning and/or root aeration systems. Other data required on this plan must show the trees canopy line, actual tree barricade limits (2/3 of the drip line and/or in the root prune lines if required), and the tree barricade detail. And any other pertinent information the arborist feels relates to tree preservation. Provide prior to building permit. Landscaping: No Comments Parks and Recreation: No issues - office building on less than one acre Stormwater: 1 . Prior to building permit the following items to be addressed: 1. Provide cross-sections at property lines, show no adverse impacts. 2. Provide SWFWMD Modification of Permit 3. Provide a 35% Littoral Zone concentrated near the pond outfall. 4. Provide a written narrative to accommodate calculations. Narrative should include discussion on methodology, history, hydrology, hydraulics and basis for all assumptions made. Solid Waste: No Comments Development Review Agenda - Thursday, August 4, 2005 - Page 30 Traffic Engineering: • Reverse the one-way flow and angle parking thereby eliminating 3-way stop. 2. Show turning template for a passenger car maneuvering at turns. 3. Show dimensions for angled parking spaces including angle in degrees used. Angled parking must comply with City standard dimensions. 4. Provide curb radius and driveway width compliant with the City's Fire Department requirements. 5. Provide an accessible path from a building's accessible entrance to a public sidewalk and to multiple buildings on site compliant with Florida Accessibility Code for Building Construction Chapter 11, Section 11-4.3.2. 6.Show 20' x 20' sight visibility triangles at the driveways. (City's Community Development Code, Section 3-904). 7. Provide a 12'x 35' loading space per City's Community Development Code, Section 3-1406 B.1.. 8. Overhang must be a minimum of 8'2" vertical clear to accommodate H/C van. 9. Provide sidewalk(s) along the property's frontage on SunnyDale Boulevard and Belcher Road. (Development Code Sections 3-1701 and 3-1907 and Clearwater Contract Specifications and Standards, Article 30) 10. All substandard sidewalks and sidewalk ramps adjacent to or a part of the project must be upgraded to City standards, including A.D.A. 11. Obtain an approved right-of-way permit from Pinellas County for any work in a county right-of-way required prior to issuance of a building permit. All of the above to be addressed prior to a D.O.. Prior to C.O.: 1. Applicant needs to provide a copy of the recorded cross-access parking agreement binding upon successive property owners. General note: Transportation Impact Fee of 10,150 sq.ft. x ($3,292/1,000 sq.ft.) _ $33,413.80 to be paid priort o a C.O.. Planning: 1 . Clarify. How is the office use in harmony with the scale, bulk, coverage, density, and character of adjacent properties? Reply to each seperately. 2. Clarify. How will the office use not discourage or hinder the appropriate development and use of adjacent land and buildings or significantly impair the value thereof? 3 . Clarify. How will the office use not adversely affect the health or safety or persons residing or working in the neighborhood? 4. Clarify. How is the office use designed to minimize traffic congestion? 5 . Clarify. How is the office use consistent with the community. character of the immediate vicinity? 6. Clarify. How does the office use minimize adverse effects, including visual, acoustic, olfactory, and hours of operation impacts, on adjacent properties? Reply to each seperately. 7. Address how Flexibility Criteria is being met: (Building Height) The increased height results in an improved site plan, landscaping area in excess of the minimum required or improved design and appearance. 8. Address how Flexibility Criteria is being met: (Building Height) The increased height will not reduce the vertical component of the view from any adjacent residential property. 9. Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback does not prevent access to the rear of any building by emergency vehicles; 10. Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback results in an improved site plan, more efficient parking or improved design and appearance. 11 . Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback does not reduce the amount of landscaped area otherwise required. 12. Provide an estimated project value for this development. Other: No Comments Notes: Insufficient. Please address comments and resubmit seven sets of revisions to Sherry Watlkins, Administrative Analyst, Planning Department (562-4582) Development Review Agenda - Thursday, August 4, 2005 - Page 31 n 1% • • Case Number: FLS2005-06040 -- 1822 N BELCHER RD Owner(s): George G Papas, Attorney 901 N Hercules Ave Ste C Clearwater, Fl 33765 TELEPHONE: 727-447-4999, FAX: 727-447-4989, E-MAIL: No Email Applicant Papas & Sons, Llc 2632 Velventos Drive Clearwater, Fl 33761 TELEPHONE: 727-787-6146, FAX: No Fax, E-MAIL: No Email Location: 0.499 acres located at the northwest corner of the intersection of Belcher Road and Sunnydale Blvd. Atlas Page: 262B Zoning District: IRT, Industrial, Research and Technology/G' druA?i4t% Request: Flexible Standard Development approval to construct a 10,150 square foot , two-story office building. The request includes: an increase to the maximum building height from 25 feet to 36.5 feet, a side (north) setback reduction from 10 feet to three feet (to building), a side (north) setback reduction from 10 feet to zero feet (to pavement), a side (west) setback reduction from 10 feet to zero feet (to pavement), a front (east setback reduction from 25 feet to 20 feet (to pavement), and a front (south) setback reduction from 25 feet to 20 feet (to pavement), per Section 2-703.I. Proposed Use: Offices Neighborhood Clearwater Neighborhoods Coalition Association(s): Clearwater, Fl 33761 2544 Frisco Drive TELEPHONE: 727-725-3345, FAX: No Fax, E-MAIL: Djw@gte.net Presenter: John Schodtler, Planner I Attendees Included: The DRC reviewed this application with the following comments: General Engineering: 1 . 1. A sewer lateral constructed in accordance with City of Clearwater Contract Specifications and Standards Index # 305 shall be installed at developer's cost. 2. The City of Clearwater will provide water tap, set the water meter and a B.F.P.D. (back flow preventor device) if applicable. Applicant is responsible for all associated fees and all other installation fees. 3. Need sidewalk(s) installed within all right-of-way(s) adjacent to this site per City's Standards and Specifications, and must be installed prior to issuance of a C.O. per Community Development Code Section 3-1701. (4-foot wide on Sunnydale Street and 5-foot wide on Belcher Road). 4. Please note, a Pinellas County right-of-way permit is required for all work taking place in Belcher Road right-of-way. 5. How is solid waste to be handled? Environmental: 1 . Provide and show on the site plan a fire hydrant within 300 ft. Please acknowledge intent to comply PRIOR TO D.O. 2 . No Issues Fire: 15", f i? I P, C OL tA) A-,4 Development Review Agenda - Thursday, August 4, 2005 - Page 87 Y. , • • 1 , ***PLEASE NOTE*** REVIEW AND APPROVAL BY THE AUTHORITY HAVING JURISDICTION SHALL NOT RELEIVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE 2004 EDITION. This DRC review by Fire is not an approval or review of any construction plans or documents other than site work. Please acknowledge PRIOR TO D.O. 2. Provide and show on the site plan 24 ft wide driveway and drive aisles for emergency vehicle ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 3 . Provide and show on the site plan minimum 30 degree turning radii for emergency vehicle ingress and egress. Please acknowledge intent to comply PRIOR TO D.O. 4. All grates and drain covers in drive aisles must meet HS-20 specifications, to support live loads of 80,000 lb. emergency vehicles. Please acknowledge intent to comply PRIOR TO D.O. 5. Depending on type of construction used in the building, a fire sprinkler system may be required to accommodate ground level parking of vehicles under second story overhang. Please acknowledge intent to comply PRIOR TO D.O. Harbor Master: No Comments Legal: No Comments Land Resources: No Comments Landscaping: No Comments Parks and Recreation: I . No issues - office building on less than one acre Stormwater: I . Prior to building permit the following items to be addressed: 1. Provide cross-sections at property lines, show no adverse impacts. 2. Provide SWFWMD Modification of Permit 3. Provide a 35% Littoral Zone concentrated near the pond outfall. 4. Provide a written narrative to accommodate calculations. Narrative should include discussion on methodology, history, hydrology, hydraulics and basis for all assumptions made. Solid Waste: No Comments Traffic Engineering: Development Review Agenda - Thursday, August 4, 2005 - Page 88 Reverse the one-way flow and angle parking thereby eliminating 3-way stop. 2. Show turning template for a passenger car maneuvering at turns. 3. Show dimensions for angled parking spaces including angle in degrees used. Angled parking must comply with City standard dimensions. 4. Provide curb radius and driveway width compliant with the City's Fire Department requirements. 5. Provide an accessible path from a building's accessible entrance to a public sidewalk and to multiple buildings on site compliant with Florida Accessibility Code for Building Construction Chapter 11, Section 11-4.3.2. 6.Show 20' x 20' sight visibility triangles at the driveways. (City's Community Development Code, Section 3-904). 7. Provide a 12'x 35' loading space per City's Community Development Code, Section 3-1406 B.1.. 8. Overhang must be a minimum of 8'2" vertical clear to accommodate H/C van. 9. Provide sidewalk(s) along the property's frontage on SunnyDale Boulevard and Belcher Road. (Development Code Sections 3-1701 and 3-1907 and Clearwater Contract Specifications and Standards, Article 30) 10. All substandard sidewalks and sidewalk ramps adjacent to or a part of the project must be upgraded to City standards, including A.D.A. 11. Attain an approved right-of-way permit from Pinellas County for any work in a county right-of-way required prior to issuance of a building permit. All of the above to be addressed prior to a D.O.. General note: Transportation Impact Fee of 10,150 sq.ft. x ($3,292/1,000 sq.ft.) _ $33,413.80 to be paid priort o a C.O.. Planning: 1 . Clarify. How is the office use in harmony with the scale, bulk, coverage, density, and character of adjacent properties? Reply to each seperately. 2. Clarify. How will the office use not discourage or hinder the appropriate development and use of adjacent land and buildings or significantly impair the value thereof? 3 . Clarify. How will the office use not adversely affect the health or safety or persons residing or working in the neighborhood? 4. Clarify. How is the office use designed to minimize traffic congestion? 5 . Clarify. How is the office use consistent with the community character of the immediate vicinity? 6. Clarify. How does the office use minimize adverse effects, including visual, acoustic, olfactory, and hours of operation impacts, on adjacent properties? Reply to each seperately. 7. Address how Flexibility Criteria is being met: (Building Height) The increased height results in an improved site plan, landscaping area in excess of the minimum required or improved design and appearance. 8. Address how Flexibility Criteria is being met: (Building Height) The increased height will not reduce the vertical component of the view from any adjacent residential property. 9. Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback does not prevent access to the rear of any building by emergency vehicles; 10. Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback results in an improved site plan, more efficient parking or improved design and appearance. 11 . Address how the side setback Flexibility Criteria are being met: The reduction in side and rear setback does not reduce the amount of landscaped area otherwise required. Other: No Comments Notes: St? Qop lQ?l-J& 1 N6 SXGa ? ?tLB'bt. 12?'S?90fLA ? (T ErJ6 ' I ,.? G e,ssS?EGRGs5 S»WrW VWO - o r "'Y 0vJ 0+4E s14>5 ? (-6a b /YD ASS 6s S 'T? WXi ri 15WAYLAt-06 Development Review Agenda - Thursday, August 4, 2005 - Page 89 • f/ lbommunity Response Team Planning Dept. Cases - DRC Case No. VLS5- OO Meeting Date: ?Nlo? Location: 1 11 -P-)e &-C r Rd ? Current Use: ? Active Code Enforcement Case (0 yes: ? Address number (yes) (no) acant -Ian-- ? Landscaping (yes) Rio ? Overgrown es ? Debris & (no) ? Inoperative vehicle(s) (yes) n° ? Building(s) (good) (fair) (poor) scant Ian ? Fencing on )) (good) (dilapidated) (broken and/or missing pieces) X Paint (good) (fair) (poor) (garish) ? Grass Parking (yes) no ? Residential Parking Violations (yes) o Signage ok (not ok) (billboard) ,(§? ? Parking n/a (striped) (handicapped) (needs repaving) ,)KC Dumpster (enclosed) (not enclosed) ? ,Outdoor storage (yes) no Comments/Status Report (attach any pertinent documents): Date:-' OS Reviewed by: Co Telephone: 4'79`1. Revised 01-29-0-1; 02-04-03 0 • LL CITY OF CLEARWATER ° Clearwater PLANNING DEPARTMENT MUNICIPAL SERVICES BUILDING 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE: (727) 562-4567 FAX: (727) 562-4576 W WW.MYCLEARWATER.COM July 21, 2005 RE: NOTICE OF FILING OF AN APPLICATION FOR FLEXIBLE STANDARD DEVELOPMENT APPROVAL AT 1822 N BELCHER RD (FLS2005-06040) To Surrounding Property Owners: As a property owner within 200 feet of 1822 N BELCHER RD, the City of Clearwater Planning Department gives notice that an application for Flexible Standard Development approval to construct a 10,150 square foot , two-story office building. The request includes: an increase to the maximum building height from 25 feet to 36.5 feet, a side (north) setback reduction from 10 feet to three feet (to building), a side (north) setback reduction from 10 feet to zero feet (to pavement), a side (west) setback reduction from 10 feet to zero feet (to pavement), a front (east setback reduction from 25 feet to 20 feet (to pavement), and a front (south) setback reduction from 25 feet to 20 feet (to pavement), per Section 2-7031. On August 04, 2005, the Development Review Committee (composed of the City's professional staff) will review and determine whether the application demonstrates compliance with the City's Community Development Code. Following that review and determiniation, the Planning Director will issue a Development Order approving, approving with conditions, or denying the application. The earliest date that the City will make a decision on the application will be August 04, 2005. The City encourages you to participate in the review of this application. You may contact me at 727-5624547 or John.Schodtler@myclearwater.com for further information, visit our office to review the files and/or submit written comments to be considered in the City's review of the application. Please be advised that the applicant may submit additional or new information regarding this case; which you may review during regular business hours. However, no further notice will be provided to you should the application be amended. An appeal of the decision of the Planning Director may be initiated by the applicant or property owners within the required notice area who present competent substantial evidence at, or prior to, the Development Review Committee meeting on August 04, 2005 . An appeal must be filed, including an appeal fee, with the Planning Department within seven days of the date of the Development Order. Thank you for your interest in the City of Clearwater's development review process. You may access our Planning Department through the City's website: www.myclearwater.com. Sincerely yours, John Schodtler Planner I Letter of Notification - FLS2005-06040 - 1822 N BELCHER RD FOUNTAINS BAYWAY INC BAYWAY MANAGEMENT INC 3802 S WESTSHORE BLVD TAMPA FL 33611 - 1002 MINIERI SEMINOLE INC 29656 US HIGHWAY 19 N STE 100 CLEARWATER FL 33761 - SWOPE, RUSSELL H SWOPE, DORIS J 2101 SUNSET POINT RD # 1002 CLEARWATER FL 33765 - 1278 ANDRE, PATRICIA A 2101 SUNSET POINT RD # 1401 CLEARWATER FL 33765 - 1250 WOOD, JACK B WOOD, DOROTHY M 2101 SUNSET POINT RD # 1404 CLEARWATER FL 33765 - 1250 YOST, L MARTIN YOST, ELISABETH A 1431 RIDGETOP WAY CLEARWATER FL 33765 - 1733 Clearwater Neighborhood Coalition Doug Williams P O Box 8204 Clearwater, Fl 33758 0 RUTZ, CHARLES J THE RUTZ, JANET C THE 2694 BRATTLE LN CLEARWATER FL 33761 - 1200 NISK, ALICE H THE NISK, RONALD P THE 2170 SUNNYDALE BLVD STE W CLEARWATER FL 33765 - 1212 SOVRAN ACQUISITION LTD 6467 MAIN ST BUFFALO NY 14221 - 5856 BOLLENBACK, BARBARA 2101 SUNSET POINT RD # 1003 CLEARWATER FL 33765 - 1278 SNYDER, MELISSA A PO BOX 16685 CLEARWATER FL 33766 - 6685 CICATELLO, THOMAS F CICATELLO, THERESA A 2101 SUNSET POINT RD # 1405 CLEARWATER FL 33765 - 1250 BELCHER POINT ASSN INC 1831 N BELCHER RD STE G-3 CLEARWATER FL 33765 - 1453 FLS2005-06040 FL- Sa-avs-v 6 o e-16 197/?v SOURCE RESEARCH INC 2160 SUNNYDALE BLVD CLEARWATER FL 33765 - 1203 MATHEWS, ROGER W JR MATHEWS, JAQUELYN F 6851 66TH ST PINELLAS PARK FL 33781 - 5037 SETLOCK, MARION L THE 2101 SUNSET POINT RD # 1001 CLEARWATER FL 33765 - 1278 WOOD, ERNEST P WOOD, MURIEL C 2101 SUNSET POINT RD # 1004 CLEARWATER FL 33765 - 1278 HELM, MARION H THE 2101 SUNSET POINT RD # 1403 CLEARWATER FL 33765 - 1250 DAZA, ARMANDO 2101 SUNSET POINT RD # 1406 CLEARWATER FL 33765 - 1250 `Clearwater U July 08, 2005 George G Papas, Attorney 901 N Hercules Ave Ste C Clearwater, F133765 t CITY OF CLE RWATER r PLANNING DEPARTMENT MUNICIPAL SERVICES BUILDING 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE: (727) 562-4567 FAX: (727) 562-4576 W W W . MYC LEARW AT ER. C OM RE: FLS2005-06040 -- 1822 N BELCHER RD -- Letter of Completeness Dear George G Papas, Attorney : The Planning Staff has entered your application into the Department's filing system and assigned the case number: FLS2005-06040. After a preliminary review of the submitted documents, staff has determined that the application is Complete. The Development Review Committee (DRC) will review the application for sufficiency on August 04, 2005, in the Planning Department conference room - Room 216 - on the second floor of the Municipal Services Building. The building is located at 100 South Myrtle Avenue in downtown Clearwater. Please call Sherry Watkins, Administrative Analyst, at 727-562-4582 no earlier than one week prior to the meeting date for the approximate time that your case will be reviewed. You or your representative (as applicable) must be present to answer any questions that the DRC may have regarding your application. Additional comments may be generated by the DRC at the time of the meeting. If you have any questions, please do not hesitate to contact me at 727-562-4604 or John. Schodtler@myclearwater.com. Sincerely yours, John Schodtler Planner I Letter or Completeness - FLS2005-06040 - 1822 N BELCHER RD `i'-F) el %, I *so Jul. 08 2005 01:35PM YOUR LOGO CityOfClearwater-Plan Dept YOUR FAX NO. 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 94474989 Jul.08 01:35PM 00'43 SND 01 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX (435-7329). FROM 1'Gji' ; .. _ c'2, '?• a°d' 1=? T? rm: mi. !Fi? 41I.5'S C• a?; ?+l'?3 + o? } ate PLANNING•DE.PARTM, ENT A ,MWAL SERVICES Bi.IILDIN(J E? 100 SOUTTI MYRTLn AVENUE, *~ PARWATER, FLORIDA. 33756 TELEPHONE: (727) 562-4567 FAX: (727) 562-4576 W WV.MYCLEARWATER.CUM ?uly 05, 2000 Ceor?e 0 Papas, Attorney 901 N enulem Ave Me C C'.learwater, , r11.3765 RE., FLS2005-WO40 --1822 N BELCHER Rte -- Letta.r of Incomplewiess Dear George G J'apas, Anamay The Ylnm zg Staff haA Offered your application ir?to5 the Departmcnt's filing system attd.,migr:ed the case nu=bw 1,1,;2nd5-W1 40, Aft-or a. pre'itWwry review of the suhii- tted docutnott*.s, staff has that the application is I? with the foL'owin& cor?inants. !. NoCd one Sxgtaerl.lrJraci Sealed survey. V2. Traffic Tmpact Sa idy a6mowledgment on page S of the ?Mlication was not addressed (see 3tctiozi K.). Section 4.202 of tho Cotnuzuaity Devclopmeot Code states Oita if all appiicati,oc: ;M deemed imomplere, tlx: deficiencies of the application shai 1 be specified by Staff. No furti-ior dayclopmani mvicw action sha11 be taken until the def.aicncics are corrccted and the applicatiom is de-wined c:o pletc, T'lcaso resubi t by T csday, July 12, 2005 (12:00 notnl). If you have arly tltwst4c7 u, pleaw do tiot hciitatc to couttict. inc at 727-562-44604 at Johu.S chodd,er@myelaarw ater,ccim. Sincmly ysyttnl+, jahu Schodt:le'r Plancer I i/iatnv o/'7naa?rerr.9?? FL?sra:??,7?r?r,• /a?: r: arr::r;;,RF;; Clearwater U July 05, 2005 George G Papas, Attorney 901 N Hercules Ave Ste C Clearwater, Fl 33765 *fte CITY OF CLEiRWATER PLANNING DEPARTMENT MUNICIPAL SERVICES BUILDING 100 SOUTH MYRTLE AVENUE, CLEARWATER, FLORIDA 33756 TELEPHONE: (727) 562-4567 FAX: (727) 562-4576 WW W.MYCLEARWATER.COM RE: FLS2005-06040 -- 1822 N BELCHER RD -- Letter of Incompleteness Dear George G Papas, Attorney : The Planning Staff has entered your application into the Department's filing system and assigned the case number: FLS2005-06040. After a preliminary review of the submitted documents, staff has determined that the application is Incomplete with the following comments. 1. Need one Signed and Sealed survey. 2. Traffic Impact Study acknowledgement on page 5 of the application was not addressed (see section K). Section 4-202 of the Community Development Code states that if an application is deemed incomplete, the deficiencies of the application shall be specified by Staff. No further development review action shall be taken until the deficiencies are corrected and the application is deemed complete. Please resubmit by Tuesday, July 12, 2005 (12:00 noon). If you have any questions, please do not hesitate to contact me at 727-562-4604 or John. Schodtler@myclearwater.com. Sincerely yours, John Schodtler Planner I Letter oflncompleteness - PLS2005-06040 - 1822 N BELCHER RD i Jul. 05 2005 04:22PM YOUR LOGO : CityOfClearwater-Plan Dept YOUR FAX NO. : 727 562 4865 NO. OTHER FACSIMILE START TIME USAGE TIME MODE PAGES RESULT 01 94474989 Jul.05 04:22PM 00'40 SND 01 OK TO TURN OFF REPORT, PRESS 'MENU' #04. THEN SELECT OFF BY USING '+' OR '-'. FOR FAX ADVANTAGE ASSISTANCE, PLEASE CALL 1-800-HELP-FAX C435-7329). Pinellas County Property Appraiser Information: 01 29 15 55950 000 0010 Page 2 of 4 Q 01 / 29 / 15 / 55950 / 000 / 0010 28-Jul-2005 Jim Smith, CFA Pinellas County Property Appraiser 15:28:57 Ownership Information Non-Residential Property Address, Use, and Sales LOUKATARIS, DIMITRIOS OBK: 14219 OPG: 1818 LOUKATARIS, ANNA 1868 RIDGEWAY DR CLEARWATER FL 33755 EVAC: Nan-EUAC Comparable sales value as Prop Addr: 1834 B'EL CHER'RD N of Jan 1, 2004, based on Census Tract; 267.02 sales from 2002 - 2003: 0 Sale Date OR Book/Page Price (Qual/UnQ) Vac/Imp Plat Information 4 /2,005 14,219/1,818 800,000 (Q) I 1993: Book 109 Pgs 036- 0 /0 0/ 0 0 { } 0000: Book Pgs - 0 /0 0/ 0 0 { ) 0000: Book Pgs - 0 /0 01 0 0 { } 2004 Value EXEMPTIONS Just/Market: 640,000 Homestead: NO Ownership .000 Govt Exem: NO Use %: .000 Assessed/Cap; 640,000 Institutional Exem: NO Tax Exempt %: .000 Historic Exem: 0 Taxable: 640,000 Agricultural: 0 2004 Tax Information District; Cu Seawall: Frontage: Clearwater View: 04 Millage: 22.9694 Land Size Unit Land Land Land Front x Depth Price Units Meth 04 Taxes: 14,700.42 1) 0 x 0 6.00 68, 069.80 S Special Tax .00 2) 0 x 0 .00 .00 3) 0 ,x 0 . 00 .00 Without the Save-Our-Homes 4) 0 x 0 .00 .00 cap, 2004 taxes will be ; 5) 0 x 0 .00 .00 14, 700.42 6) 0 x 0 .00 .00 Without any exemptions, 2004 taxes will be ; 14,700.42 Short Legal MATHEWS/NIELSEH REPLAT PT OF LOT 1 DESC BEG SW Description CDR LOT i TH N 325.41FT TH S89DE 290.27FT TH CUR LT Building Information http://pao.co.pinellas.fl.us/htbin/cgi-scr3?o=l&a=.l &b=l &r-&s=l &u=0&p=01+29+15+5... 7/28/2005 Pinellas County Property Appraiser Information: 01 29 15 55950 000 0010 Page 3 of 4 0 0 Property and Land Use Code descriptions 01 / 29 / 15 / 55950 / 000 / 0010 :01 28-Jul-2005 Jim Smith, CFA Pinellas County Property Appraiser 15:28:57 Commercial Card 01 of i Improvement Type: Rest/Lounge/Drive-in Property Address: 1834 BELCHER RD N Prop Use: 325 Land Use: 21 Structural E1?msnts Foundation Continuous Footing Floor System Slab on Grade Exterior Wall Conc Block/Wood Height Factor 0 Party Wall None Structural Frame None Roof Frame Gable & Hip Roof Cover Composition Shingle Cabinet & Mill Average Floor Finish Carpet Combination Interior Finish Drywall Total Units 0 Heating & Air Heating&Cooling Pckg Fixtures 15 Bath Tile None Electric Average Shape Factor Rectangle Quality Average Year Built 1,993 Effective Age 10 Other Depreciation 0 Function Depreciation 0 Economic Depreciation 0 Siu13 Aromas Description Factor Area Description Factor Area 1) Base Area i. 00 5, 073 7) . 00 0 2) Open Porch .30 800 8) .00 0 3) Canopy .25 344 9) .00 0 4) .00 0 10) .00 0 5) .00 0 11) .00 0 6) .00 0 12) .00 0 GC)rnMsrcial Extra FEE3aturBs Description Dimensions Price Units Value RCD Year 1).ASPHALT 82SPACE 1.50 16,400 24,600 24,600 999 2) FENCE 126LF 16.00 126 2,020 1,370 1,993 3) .00 0 0 0 0 4) 00 0 0 0 0 5) .00 0 0 0 0 6) 00 0 0 0 0 TOTAL RECORD VALUE: 25,970 http://pao.co.pinellas.fl.us/htbin/cgi-scr3?o=1 &a=1 &b=1 &r-&s=1 &u=0&p=01+29+15+5... 7/28/2005' Pinellas County Property Appraiser Information: 01 29 15 55950 000 0010 Page 4 of 4 1w Back to Search PaLe An explanation of this screen http://pao.co.pinellas.fl.us/htbin/cgi-scr3?o=l &a=1 &b=1 &r-&s=1 &u=0&p=01+29+15+5... 7/28/2005 ? w .4y MOM (Cri, I.oNG VANGE Pi.ANNINCi 1)rVGUJI1tiTl'.NT REVIEW December 5, 2005 Mr. George Pappas 901 Hercules Avenue Suite C Clearwater, FL 33765 FAX NO. :7275624865 Dec. 08 2005 10:07Af1 P1 CITY OF C'LEARWATER PLANNING DEPARTMENT Vosti . Orpicr•. Box 474.5, I.1,A14WATVRj l'101111M 33758-4745 .MI.INICIT'AT. S[.Rviu--% RTIILDING, 3.00 Soirni MYk'I'I.Ii.Avi-mlF, CT.p.ARWNrEll, FLORIDA 33756 TL'L1.111'1QNK (727) 562-4567 FAX (727).562-4.965 GL!b [E Od[E JAN 2 5200& N EC 11 ?C?L E?Af A T EiE 8 RE: Development Order regarding case FLS2005-06040 at 1822 Belcher Road :pear Mr. Pappas: This letter collsti.tUtes a Development Order pursuant to Section 4202.E of the Community Development Code. On August 4, 2005, the Development Review Committee (DRC) reviewed your application for Flexible Standard Development approval to construct a 10,150 square foot, two-story office building. The, request includes an increase to the rn'aximum building height i'rom 25 feet to 36.5 feet, a side (north) setback reduction from. 10 feet to three feet (to building), a side (north) setback reduction from 10 feet to zero feet (to pavement), a side (west) setback reduction ft6m. 10 feet to zero feet (to pavement), a front (east setback reduction from 25 feet to 20 feet (to pavement), and a front (south) setback reduction from 25 feet to 20 feet (to pavement), per. Section 2-7031 The DRC recommended approval of the applications with the following bases and conditions: Bases for Ap rp oval: 1. The proposal complies with Office criteria under the provisions of Section 2-703.1; 2, The plan complies with General Applicability Criteria under the provisions of Section 3-913; and 3. The proposed development is compatible with the surrounding area. Conditions of Ag ro oval: 1. That a tree preservation plan prepared by a Certified Arborist be provided, prior to the issuance of a site or building permit 2. That the tree survey and landscape plan be revised to show all replacement trees in the same location from which they were i.naldvertently removed, prior to building permit .3. That a sewer lateral constructed in accordance with City of Clearwater Contract Specifications and Standards Index # 305 shall be installed at developer's cost, prior to the issuance of a building permit; 4. 't'hat a Pinellas County right-of-way permit is required for all work taking place in Belcher Road right-of-way; (-*RANK ii11WAR ), MAYOR I.W.IJONSON, VIf.R•MAYOR jonN D mm, coki,%I iimi.&m tR i iONT HAMII.IYIN, I_rnINCILMENHIRI( ® CARLEN A, nR msEN, COUNCHAlh.NWEN 'T*Q1IAL F:1%4I'LC)YM1:Mr AND ARRII<wxivli ACTION VMVIDYHR" FROP1FAX NO. :7275624865 Dec. 08 2005 10:07RM P2 December 5, 2005 FLS2005-06040 Page 2 _5. That cross-sections of existing and proposed grades at property lines showin.g .uo adverse impacts be provided prier to the issuance of a site or building permit, 6. That modifications of the SWFWMD pennit be provided prior to the issuance of a. site or building permit.; 7. 'That a 35% Littoral Zone concentrated near the pond outfall be provided prior to the issuance of a Site or building permit; 8. That a written narrative, including discussion on mehodology, history, hydrology, hydraulics and basis for all assumptions made, to accommodate storm water calculations be provided prior to the issuance of a site w building permit; 9. That a recorded copy of cross drainage agreement addressing water treatment on adjacent property be provided prior to the issuance of a site or building permit; 10. That the site plan be revised to show turning template for a passenger car maneuvering at turns prior to the issuance of a site or building permit; 11. That the site plan show parking spaces comply with City standard dimensions, including angle in degrees used., prior to the issuance ofa site or building-permit; 12. That the site plan show an accessible path from a building's accemible entrance to a pcabl..ic sidewalk and to multiple buildings on site compliant with Florida Accessibility Code for Building Construction Chapter 11, Section 11-4.3.2,.prior to the issuance of a site or building permit; 1, 3. That sight visibility triangles at the driveways be shown on the site and landscape plaits, prior to the issuance of a site or building permit; 14. That a copy of the recorded cross-access parking agreement binding upon succe"Sive property . owners lie provided, prior to the issuance of a Certificate of Occupancy; 15. 't'hat all site revisions including but not limited to: storm water, landscaping, and tree preservation, required for 1834 Belcher Road be approved and completed, prior to the issuance of a Certificate of Occupancy for 1822 Belcher Road-, and 16. That all signagc meet Code requirements and be architecturally integrated into the design of the site and buildings. I concur with the findings of the Development Review Committee and, through this letter, approve your application for Flexible Standard Development with above 15 conditions. The approval is based on and must adhere to the application dated received Tune 17, 2005 and revised rite plans and building elevations dated received November 17, 2005. Pursuant to Section 4-303, an application for a building permit shall be made within one year of Flexible Standard Development approval (December 5, 2006). All required certificates of occupancy shall be obtained within. two years of the date of i4uance of the building permit. Time frames do not change with successive owners. An extension of time may be granted by the Community Development Coordinator for a period not to exceed one year and only within the original period of validity. T.he Community Development Coordinator may approve an. additional extension of time not to exceed one year for good, cause shown and documented in writing. The coordinator must + receive the request for this extension within the one-year period of validity after the original time extension. The Community Development. Coordinator tnny approve an additional extension of tirtie not s; ?rt?„:„?,, t,?:f,,,r ??,rn/1G'P ItV7cx S/undard (FL S)Vn(r rive or Finished CavrABrIcher Rd N 1822 (C) JVMLS2005-06040 Devolopment Ordandor. i. 1 i FROPi-? FAX NO. :7275624865 Dec. 08 2005 10:00AM p3 Deeerriber 5, 2005 FI S2005-06040 Page 3 ' to exceed on year for good Qause shown and documented in writing. The coordinator niu,tit receive the request for this extension within the one-yeas period of the validity after the original extension. The issuance of this Development Order does not relieve you x)f the necessity to obtain any building permits or pay any impact fees that may be required. In order to facilitate the issuance of any pennlt or license affected. by this approval, please bring a copy of this letter with you when applying for tuiy permits or licenses that require this prior developractit approval. 1f you have any questions, please do not hesitate to call John Schodtlcr, Planner I at 727-562-4547. Sincerely, Michael elk, Al . Planning Director s SAPlnnnln,i; C?e?CUallgandC U DU7ex titandnrd (FJ S)Unaetive or h'ln4ckpd CauceslJlelrher Rd N 1822 (C)1K571.72005-06010 Development nrder.doc Revised Shared Parking Calculations for 1822 North Belcher Road. Eh Minimum Minimum USE #1 USE #2 WEEKDAY WEE KEND Office Night Midnight - Restaurant 6 a.m. Day 9 a.m. - 4 p.m. Evening 6 p.m. midnight Day 9 a.m. - 4 p.m. Evening 6 p.m. mi night 3-4/1000 GFA 5% 100 % 10% 10 % 5% 28 41 1 2 28 41 3 4 3 4 1 2 37 76 4 8 19 38 37 76 19 38 37 76 7-15/1000 fa 10% 50% 100% 50% 100% 65 117 5 10 47 79 40 80 21 42 38 78 A minimum of 80 parking spaces are required per the Shared Parking Calculations. The proposal is for 95 parking spaces. I-f 0313o1v r it Pappas Out Parcel 4 I C; L-Ln w¢a rfi Existing Data Total Area = 0.499 acres Assume No development and design system for both parcels C=0.2 Cn = 73 (weeds, Brush, D-soil) tc = 120'= 279 sec = 4.65 minutes, use 15 minutes (min) 0.43 S = 50-',49 =.83% 120 .5 V=.47(.83)=.43 NONW??. 0 '''' r ., rn Co s - IS.1 m g Iii n CO O t*J "6 G) m CD ICod, cn :5- 1 II"I" I 0 op IAN, co a irn a G) d ;d00 N ° N W Proposed Data Total Area = 0.499 acres Impervious Proposed Bldg Proposed asphalt & Curb Pond 4,680 sf = 10,395 sf 2,303 sf 17,378 sf = .399 acres Proposed C = .399 ac x 1.0 = .399 +.100 acx0.2= .020 ------ --------- 0.499 ac .419 Proposed C = 0.419 =.84 0.499 Proposed Cn = .399 ac x 100 = 39.90 + .100 ac x 73= 7.30 ------- ------- 0.499 ac 47.2 Proposed CN = 47.20 = 94.6 0.499 ac Proposed tc = 15 minutes (min) 3' r Pond Data 3&4 / 1 slope El (ft) Area Volume 49 26 0 50 934 480 51 2,303 2,099 SHWT = 49.0' First 1" = .5 x .499 ac x 43560 = 906 cf 2 12 Set weir @ Bottom 1/2" Volume = 0 SF + 0.906 sf = 906 sf or Elev. 50.26' Horizontal Permeability = 2.0 Ft/Day W/S.F. = 2.0 L = 190' W= 12' PONDS Version 3.2.0108 Retention Pond Recovery - Refined Method Copyright 2000 Devo Seereeram, Ph.D., P.E. Proiect Data Project Name: Simulation Description: Project Number: Engineer : Supervising Engineer. Date: Aquifer Data PAPPAS 25 YR 24 HR STORM 01 HOFMANN HOFMANN 2-9-06 Base Of Aquifer Elevation, [B] (ft datum): Water Table Elevation, [WT] (ft datum): Horizontal Saturated Hydraulic Conductivity, [Kh] (ft/day): Fillable Porosity, [n] (%): Vertical infiltration was not considered. Geometry Data Equivalent Pond Length, [L] (ft): 190.0 Equivalent Pond Width, [W] (ft): 12.0 Ground water mound is expected to intersect the pond bottom Stage vs Area Data Stage Area (ft datum) (ft2) 49.00 26.0 50.00 934.0 51.00 2303.0 Discharae Structures Discharge Structure #1 is active as weir Structure Parameters Description: RECTANGULAR WEIR Weir elevation, (ft datum): 50.4 Weir coefficient: 3.33 Weir length, (ft): 1.5 Weir exponent: 1.5 Tailwater - disabled, free discharge PAPPAS 46.00 48.00 2.00 30.00 02-09-2006 09:43:45 Pagel PONDS Version 3.2.0108 Retention Pond Recovery - Refined Method Copyright 2000 Demo Seereeram, Ph.D., P.E. Discharge Structures (contd.) Discharge Structure #2 is inactive Discharge Structure #3 is inactive PAPPAS 02-09-2006 09:43:46 Page 2 F i PONDS Version 3.2.0100 Retention Pond Recovery - Refined Method Copyright 2000 Devo Seereeram, Ph.D., P.E. Scenario Input Data • Scenario 1 :: FIRST 1/2" OF TREATMENT VOLUME Hydrograph Type: Slug Load Modflow Routing: Routed with infiltration Treatment Volume (W) 906 Initial ground water level (ft datum) default, 48.00 Time After Time After Storm Event Storm Event (days) (days) 0.100 2.000 0.250 2.500 0.500 3.000 1.000 3.500 1.500 4.000 Scenario 2 .: EXISTING 25YR 24 HR STORM Hydrograph Type: Inline SCS • Modflow Routing: Not routed Repetitions: 1 Basin Area (acres) 0.499 Time Of Concentration (minutes) 15.0 DCIA (%) 0.0 Cure Number 73 Design Rainfall Depth (inches) 9.0 Design Rainfall Duration (hours) 24.0 Shape Factor UHG 256 Rainfall Distribution SCS Type II Florida Modified Initial ground water level (ft datum) default, 48.00 No times after storm specified. Scenario 3 :: PROPOSED 25 YR 24 HR STORM Hydrograph Type: Inline SCS Modflow Routing: Routed with infiltration Repetitions: 1 ' Basin Area (acres) 0.499 Time Of Concentration (minutes) 15.0 DCIA (%) 0.0 Cure Number 94.6 Design Rainfall Depth (inches) . 9.0 Design Rainfall Duration (hours) 24.0 Shape Factor UHG 256 Rainfall Distribution SCS Type II Florida Modified • Initial ground water level (ft datum) default, 48.00 No times after storm specified. PAPPAS 02-09-2006 09:43:47 Page 3 PONDS Version 3.2.0108 Retention Pond Recovery e Refined Method Copyright 2000 Devo Seereeram, Ph.D., P.E. Summary of Results :: Scenario 1 :: FIRST 1/2" OF TREATMENT VOLUME Time Stage Rate Volume (hours) (ft datum) (ft3/s) (TP)_ Stage Minimum 96.000 48.74 Maximum 0.002 50.36 Inflow Rate - Maximum - Positive 0.002 Rate - Maximum - Negative None Cumulative Volume - Maximum Positive 0.002 Cumulative Volume - Maximum Negative None Cumulative Volume - End of Simulation 96.000 Infiltration Rate - Maximum - Positive 0.002 Rate - Maximum - Negative None Cumulative Volume - Maximum Positive 48.000 Cumulative Volume - Maximum Negative None Cumulative Volume - End of Simulation 96.000 Combined Discharge Rate - Maximum - Positive None Rate - Maximum - Negative None Cumulative Volume - Maximum Positive None Cumulative Volume - Maximum Negative None Cumulative Volume - End of Simulation 96.000 Discharge Structure 1 - simple weir Rate - Maximum - Positive None Rate - Maximum - Negative None Cumulative Volume - Maximum Positive None Cumulative Volume - Maximum Negative None Cumulative Volume - End of Simulation 96.000 Discharge Structure 2 - inactive Rate - Maximum - Positive disabled Rate - Maximum - Negative disabled Cumulative Volume - Maximum Positive disabled Cumulative Volume - Maximum Negative disabled Cumulative Volume - End of Simulation disabled Discharge Structure 3 - inactive Rate - Maximum - Positive disabled Rate - Maximum - Negative disabled Cumulative Volume - Maximum Positive disabled Cumulative Volume - Maximum Negative disabled Cumulative Volume - End of Simulation disabled Pollution Abatement: 36 Hour Stage and Infiltration Volume 36.000 49.02 72 Hour Stage and Infiltration Volume 72.000 48.82 151.0000 None 0.0442 None None None None None disabled disabled disabled disabled 906.0 None 906.0 906.0 None 906.0 None None 0.0 None None 0.0 disabled disabled disabled disabled disabled disabled 905.2 906.0 PAPPAS 02-09-2006 09:43:47 Page 4 r PONDS Version 3.2.0108 Retention Pond Recovery - Refined Method Copyright 2000 Devo Seereeram, Ph.D., P.E. Summary of Results Scenario 2 :: EXISTING 25YR 24 HR STORM Time Stage Rate Volume (hours) (ft datum) (ft3/s) (ft) Stage Minimum Not Available Not Available Maximum Not Available Not Available Inflow Rate - Maximum - Positive 12.067 1.5383 Rate - Maximum - Negative None None Cumulative Volume - Maximum Positive 25.467 10331.5 Cumulative Volume - Maximum Negative None None Cumulative Volume - End of Simulation 25.533 10331.5 Infiltration Rate - Maximum - Positive Not Available Not Available Rate - Maximum - Negative Not Available Not Available Cumulative Volume - Maximum Positive Not Available Not Available Cumulative Volume - Maximum Negative Not Available Not Available Cumulative Volume - End of Simulation Not Available Not Available Combined Discharge Rate - Maximum - Positive 12.067 1.5383 Rate - Maximum - Negative None None Cumulative Volume - Maximum Positive 25.467 10331.5 Cumulative Volume - Maximum Negative None None Cumulative Volume - End of Simulation 25.533 .10331.5 Discharge Structure 1 - inactive Rate - Maximum - Positive disabled disabled Rate - Maximum - Negative disabled disabled Cumulative Volume - Maximum Positive disabled disabled Cumulative Volume - Maximum Negative disabled disabled Cumulative Volume - End of Simulation disabled disabled Discharge Structure 2 - inactive Rate - Maximum - Positive disabled disabled Rate - Maximum - Negative disabled disabled Cumulative Volume - Maximum Positive disabled disabled Cumulative Volume - Maximum Negative disabled disabled Cumulative Volume - End of Simulation disabled disabled Discharge Structure 3 - inactive Rate - Maximum - Positive disabled disabled Rate - Maximum - Negative disabled disabled Cumulative Volume - Maximum Positive disabled disabled Cumulative Volume - Maximum Negative disabled disabled Cumulative Volume - End of Simulation disabled disabled Pollution Abatement: 36 Hour Stage and Infiltration Volume N.A. N.A. N_A. 72 Hour Stage and Infiltration Volume N.A. N.A. N.A. PAPPAS 02-09-2006 09:43:47 Page 5 r PONDS Version 3.2.0108 Retention Pond Recovery - Refined Method Copyright 2000 Devo Seereeram, Ph.D., P.E. Summary of Results :: Scenario 3 :: PROPOSED 25 YR 24 HR STORM Time Stage Rate Volume (hours) (ft datum) _ _ (ft3?s) (ft3) Stage Minimum 2.000 48.87 Maximum 12.167 50.92 Inflow Rate - Maximum - Positive 12.067 2.0714 Rate - Maximum - Negative None None Cumulative Volume - Maximum Positive 25.467 15119.0 Cumulative Volume - Maximum Negative None None Cumulative Volume - End of Simulation 25.533 15119.0 Infiltration Rate - Maximum - Positive 3.633 0.0371 Rate - Maximum - Negative None None Cumulative Volume - Maximum Positive 25.533 1523.8 Cumulative Volume - Maximum Negative None None Cumulative Volume - End of Simulation 25.533 1523.8 Combined Discharge Rate - Maximum - Positive 12.133 1.8706 Rate - Maximum - Negative None None Cumulative Volume - Maximum Positive 25.367 12636.9 Cumulative Volume - Maximum Negative None None Cumulative Volume - End of Simulation 25.533 12636.9 Discharge Structure 1 - simple weir Rate - Maximum - Positive 12.133 1.8706 Rate - Maximum - Negative None None Cumulative Volume - Maximum Positive 25.367 12636.9 Cumulative Volume - Maximum Negative None None Cumulative Volume - End of Simulation 25.533 12636.9 Discharge Structure 2 - inactive Rate - Maximum - Positive disabled disabled Rate - Maximum - Negative disabled disabled Cumulative Volume - Maximum Positive disabled disabled Cumulative Volume - Maximum Negative disabled disabled Cumulative Volume - End of Simulation disabled disabled Discharge Structure 3 - inactive Rate - Maximum - Positive disabled disabled Rate - Maximum - Negative disabled disabled Cumulative Volume - Maximum Positive disabled disabled Cumulative Volume - Maximum Negative disabled disabled Cumulative Volume - End of Simulation disabled disabled Pollution Abatement: 36 Hour Stage and Infiltration Volume N.A. N.A. N.A. 72 Hour Stage and Infiltration Volume N.A. N.A. N.A. PAPPAS 02-09-2006 09:43:48 Page 6