09-37
RESOLUTION NO. 09-37
A RESOLUTION ADOPTING THE FLOODPLAIN
MANAGEMENT PLAN: TRANSMITTING THE PLAN TO
THE FEDERAL EMERGENCY MANAGEMENT AGENCY
AS REQUIRED BY THE NATIONAL FLOOD INSURANCE
PROGRAM'S COMMUNITY RATING SYSTEM;
AUTHORIZING THE CITY MANAGER TO INITIATE
ACTIVITIES AS RECOMMENDED IN THE FLOODPLAIN
MANAGEMENT PLAN; AND PROVIDING AN EFFECTIVE
DATE.
WHEREAS, the National Flood Insurance Program (NFIP) provides federally
supported flood insurance in communities that regulate development in their floodplains,
and the Community Rating System (CRS) reduces flood insurance premiums in those
communities that do more than implement the minimum regulatory requirements; and,
WHEREAS, the City of Clearwater is required to update the Floodplain
Management Plan in order to continue to receive CRS credits for this document; and
WHEREAS, the City Council adopted Floodplain Management Plans in 2000 and
2004, which updated the Repetitive Loss Plan adopted on December 11, 1991; and
WHEREAS, the Floodplain Management Plan updates the 2004 Floodplain
Management Plan in compliance with the 2007 CRS Coordinators Manual; and
WHEREAS, the Floodplain Management Plan as amended is consistent with the
Clearwater's adopted Comprehensive Plan; and
WHEREAS, adopting the Floodplain Management Plan will provide the citizens
of Clearwater access to the Flood Hazard Mitigation Assistance program funds; and
WHEREAS, various City projects, programs, operations and initiatives in the Plan
may lower flood insurance rates for the City residents; now, therefore
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY
OF CLEARWATER, FLORIDA:
Section 1. The Floodplain Management Plan as amended and attached hereto is
adopted.
Section 2. The Floodplain Management Plan shall be transmitted to the Federal
Emergency Management Agency for appropriate action as required under the National
Flood Insurance Program's Community Rating System.
Resolution No. 09-37
Section 3. The City Manger is authorized to initiate activities as recommended in
the Floodplain Management Plan.
Section 4. This resolution shall take effect immediately upon adoption.
PASSED AND ADOPTED this 17th day of September
,2009.
~i/~
Frank V. Hibbard
Mayor
Approved as to form:
Attest:
'~4L
Ji-_D_~ _
--
Leslie K. Douga -
City Attorney
2
Resolution No. 09-37
City of Clearwater
Floodplain Management Plan
City Council Approval: September 17, 2009
Resolution No. 09-37
Clearwater City Council
Frank Hibbard, Mayor
Paul F. Gibson, Vice-Mayor
John Doran
Carlen Petersen
George N. Cretekos
City Administration
William B. Horne II, City Manager
Rod Irwin, Assistant City Manager
Jill Silverboard, Assistant City Manager
Pamela K. Akin, City Attorney
City Staff
Scott Rice, Engineering Assistant Director
Elliot Shoberg, Engineering Stormwater Manager
Muhammad Abdur-Rahim, Stormwater Maintenance Manager
Allison McKinney, CRS Coordinator - Engineering / Stormwater
Ozell George, Public Services Supervisor II
Catherine Lee, Planner II
Heather Shell, Public Communication
James Hersh, Engineering / GIS
Jack Fahey, Plans Examiner - Dev & Neighbor Services
>-
I-
u..
o
u
~ ~learwater
u~
2
s: IESM\StaffiAMcKinney\2009 _FLOODPLAIN _ MANAG EMENT ]LAN12009
FMPI2009 ylan_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Table of Contents
SECTION 1.0 INTRODUCTION ...................... ............ ......... .... ........... ........ .......................5
SECTION 2.0 PLANNING PROCESS... .............. ............... .......................... ..... ..................6
SECTION 3.0 RISK ASSESSMENT ..... ..................... ....... ............ .............. ........... .............. 7
Identifying Hazards. ........... ................................ .................. ...................... ............... .15
Profiling Hazard Events ...... .................... ............... ............... ....... ................ ............ ..16
Assessing Vulnerability..... ..................... .............. ................ ....... ..................... .........18
Identifying Assets..................................................................................................... .23
SECTION 4.0 HAZARD MITIGATION STRATEGY ........................................................26
Evaluation of Previous Plan's Activities ........ ......... .................. .................... ............26
Floodplain Regulations ................................ ........ .................. .......................... ......... .27
Identification and Analysis of Mitigation Measures ............. .................. ................. ..28
Implementation of Mitigation Activities............ ................. ..................... ........ ........ .50
SECTI ON 5.0 PLAN MAINTENANCE... .......... .................. ................................ ............... .52
Monitoring, Evaluation and Updating the Plan .........................................................52
Implementation through Existing Programs ....... ....... ............ .......... ..................... .....53
Reference...................................................................................................................... .........55
On-line Resources... ............ ........ ........ ........... ............. ... ........ .......... .............. ........................57
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendices
Appendix A - Resolution 09-37 Adopting the Floodplain Management Plan......................58
Appendix B - FMPC Meeting Minutes .................................................................................61
Appendix C - Flood Protection Questionnaire ................. ......... ................... ........................ .66
Appendix D - Community Development Code,
Chapter 51 Flood Damage Prevention ...........................................................68
Appendix E - Community Development Code, ArtA, Div. 13,
Land Clearing and Grubbing......................................................................... 84
Appendix F - Engineering Department's Erosion and Siltation Control Policy...... ...........86
Appendix G - Engineering Department's Stormwater Design Criteria ................................118
Appendix H - Engineering Department's Stormwater Management System Policy..... ......134
Appendix I - Clearwater Comprehensive Plan, Stormwater Management
Element............... ......................................................................................142
Appendix J - Application for Non-Substantial Damage/
Improvement Review............ .......... ............ ............................. ...................... .150
Appendix K - Capital Improvement Stormwater Utility Project List..... .............................165
~ @Iearwater
~~
3
S :\ESM\StaftlAMcKinney\2009 JLOODPLAIN _ MANAG EMENT _ PLAN\2009
FMP\2009 -p1an_9 _1_2009 _final.docx
4
S :\ESM\StaffiAMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9 _1_2009 jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Figu res
Figure 1.0 - Clearwater Service Area vs Clearwater Landmass Including SFHA
Comparison
Figure 2.0 - Southwest Florida Water Management District (SWFWMD) Drainage
Basins
Figure 3.0 - SWFWMD Drainage Basins within Clearwater
Figure 4.0 - Clearwater Zoning Boundaries and Drainage Basins
Figure 5.0 - Pine lias County Future Land Use Boundaries and Drainage Basins
Figure 6.0 - Topographic Map
Figure 7.0 - FEMA Special Flood Hazard Areas (SFHA) and SWFWMD Drainage
Basins
Figure 8.0 - Clearwater Waterbodies
Figure 9.0 - Hurricane Evacuation Zones and Evacuation Routes
Figure 10.0 - Hurricane Storm Surge Areas
Figure 11.0 - Special Needs Facilities
Figure 12.0 - Repetitive Loss Property
Figure 13.0 - Critical Facilities
Figure 14.0 - Sanitary Sewer Facilities
Figure 15.0 - Natural Gas Infrastructure
Figure 16.0 - Public and Private Schools
; tlearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
SECTION 1.0 INTRODUCTION
The City of Clearwater is the second largest city in Pinellas County with 26.1
square miles and approximately 110,830 residents. Nearly half of the City's land
is devoted to residential use. The City has undergone considerable growth since
its incorporation in 1897. Between 1970 and 1990, the City's population
increased by 80 percent and the number of housing units within the City doubled.
Since 1990, the City's population has grown by approximately 11 percent and the
number of housing units has grown by approximately 25.9 percent.
Due to the amount of development constructed within the floodplain, as well as
an increase of stormwater runoff as a result of the overall increase of
development since Clearwater's incorporation, floodplain management has
become an important component in protecting the well-being of the City's people
and property. To help decrease the vulnerability of flood damage for thousands
of properties located within the coastal and floodplain areas, the City actively
participates in the Federal Emergency Management Agency's (FEMA), National
Flood Insurance Program's (NFIP), Community Rating System (CRS).
Communities that participate in the NFIP adopt and enforce floodplain
management programs in order to reduce future flood damage. In exchange, the
NFIP provides federally backed flood insurance for property owners and renters
in the participating communities. In addition to providing flood insurance and
reducing flood damage through floodplain management regulations, the NFIP
identifies and maps the Nation's floodplains.
The NFIP has been successful in requiring new buildings to be protected from
damage by a 100-year flood. However, flood damage still results from more
frequent, less intense, flooding episodes and from flooding in unmapped areas.
Under the Community Rating System (CRS), there is an incentive for
communities to do more than just regulate construction of new buildings to
minimum national standards. The CRS adjusts flood insurance premiums to
reflect community activities that reduce flood damage to existing buildings,
manage development in areas not mapped by the NFIP, protect new buildings
beyond the minimum NFIP protection level, help insurance agents obtain flood
data and help residents obtain flood insurance. The objective of the CRS is to
reward communities that are doing more than meeting the minimum NFIP
requirements to help their citizens prevent or reduce flood losses. The CRS also
provides an incentive for communities to initiate new flood protection activities.
The goal of the CRS is to encourage, by the use of flood insurance premium
adjustments, community and State activities beyond those required by the
National Flood Insurance Program to:
1. Reduce flood losses, e.g.:
. Protect public health and safety,
;tlearwater
u~
5
S :\ESM\StafflAMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMP\2009 jllan_9 _]_2009 Jinal.docx
6
S:\ESM\StaffiAMcKinney\2009 _FLOODPLAIN_MANAGEMENT _PLAN\2009
FMP\2009 ylan_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
· Reduce damage to buildings and contents,
. Prevent increases in flood damage from new construction,
· Reduce the risk of erosion damage, and
· Protect natural and beneficial floodplain functions.
2. Facilitate accurate insurance rating, and
3. Promote the awareness of flood insurance.
Initially, the City submitted a Repetitive Loss Plan to FEMA in 1991 to satisfy the
CRS requirements. On September 21, 2000, the City adopted a Floodplain
Management Plan in accordance with the then existing CRS requirements. The
Plan creates a comprehensive strategy for implementing sound floodplain
management activities and was designed in accordance with the 10-step
activities promulgated by FEMA's Disaster Mitigation Act 2000 and adopted in
Section 510 Floodplain Management Planning of the CRS Coordinator's Manual.
The 2000 Plan was updated in 2004 and adopted by the City Council by
resolution on October 21,2004.
In 2009, the City created a Floodplain Management Planning Committee (FMPC)
to review and update the floodplain management activities identified in the Plan.
In accordance with requirements of the CRS program, this 2009 update provides
a reporting of the implementation of the 2004 Plans activities, a description of the
planning process involved with the 2009 update and descriptions of current and
future projects. The City Council adopted this Update to the Plan by resolution
on September 17, 2009 at its regularly scheduled meeting. See Appendix A for a
copy of the resolution.
SECTION 2.0 PLANNING PROCESS
The FMPC was formed to complete this 2009 update and will continue to be
responsible for the review and implementation of the Plan. The FMPC consists
of the CRS coordinator and representatives from Engineering, Planning, and
Public Service Departments. The FMPC held a kick off meeting March 3, 2009
to discuss the planning process and to identify, and assign tasks. A progress
meeting held on March 30, 2009 allowed the FMPC to review technical data,
update progress, and plan a public information meeting. Members of the FMPC
met again on June 10, 2009 to prepare for the public information meeting.
Minutes from the meetings are available in Appendix B.
The public information meeting was held on June 17, 2009 at the Ross Norton
Recreation and Aquatic Complex & Extreme Sports Park located at 1426 S.
Martin Luther King Jr. Ave in Clearwater, Florida. The public information meeting
provided a forum for residents to discuss the natural hazards, problems and
possible solutions specific to their neighborhoods and to offer input on the draft
update to the plan. Representatives from Engineering and Public
; Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Service departments presented information to residents. A flood protection
questionnaire was distributed at the meeting and will be mailed to residents in
September 2009. Information obtained from the public will be incorporated into
the 2010 CRS recertification and Plan evaluation. See Appendix C for the flood
protection questionnaire
In order to enhance the plan to address the flooding needs of the City,
coordination with surrounding communities and county, regional, state and
federal agencies is required. To assist in the understanding of the technical
aspects of the Federal requirements of the 2007 CRS Coordinator's Manual, the
City's assigned CRS Specialist and the Department of Community Affairs (DCA)
Bureau of Recovery and Mitigation staff were contacted. In addition, the
Southwest Florida Water Management District (SWFWMD), the Jacksonville
District of the US Army Corps of Engineers, the Tampa Bay Regional Planning
Council (TBRPC), the Pinellas County Office of Emergency Management and the
City of Largo staffs were all contacted and notified that the Plan was being
updated. Copies of the adopted Plan will be provided to these agencies. The
City's CRS coordinator met regularly with CRS coordinators from neighboring
communities to discuss local hazard mitigation activities and floodplain
management.
Some of the tasks involved in the update of the Plan include verification of
existing data, review of the latest GIS information, review of watershed studies,
census data and Pinellas County Property Appraiser information. Drainage basin
areas and existing floodplain land use have been refined. Repetitive loss
information has been updated. New floodplain regulations have been developed
to reduce damage to buildings and contents and prevent increases in flood
damage from new construction. Information from the current City of Clearwater's
Comprehensive Plan is included under planning goals. The list of stormwater
management projects has been updated to show completed improvements and
describe current and proposed projects.
SECTION 3.0 RISK ASSESSMENT
The City of Clearwater was incorporated in 1897 at which time the area was
important as a trading post. The City remained a small town with a 1930
population of 7,607 until after World War II, when the population doubled to
15,581. Similar to the rest of Florida, Clearwater experienced significant growth
after this time.
Garden Memorial Causeway, now referred to as Memorial Causeway, was
constructed in 1928 and connected mainland Clearwater with Clearwater Beach.
The Causeway replaced an old wooden bridge and allowed for better access to
Clearwater's barrier islands. In the late 1950's, traffic counts by the
; Clearwater
u~
7
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMP\2009 -plan _9_1_2009_ finaldocx
rwater
8
S: \ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMP\2009 -plan _9_1_2009 _finaldocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Florida State Highway Department indicated 6.3 million cars annually traveled
the roadway.
During the 1950's and 1960's, dredge and fill projects were numerous in Pinellas
County. Clearwater's Island Estates neighborhood was the City's most prominent
fill project located between Clearwater Beach and the mainland. This
neighborhood was described as "Venice-type development for exclusive homes".
Although this neighborhood is located on the waterfront, only one repetitive loss
property has been identified.
From 1970 to present, Clearwater's population has more then doubled, with most
of this growth occurring between 1970 and 1990. Clearwater has become
virtually built out and experiences growth primarily through relatively small
annexations and redevelopment projects. The beach is a mix of residential and
commercial uses and is generally redeveloped on a parcel-by-parcel basis.
Figure 1.0 shows the City of Clearwater Service area and the FEMA designated
Flood zones. This figure shows the difference between the floodplain area as
designated by FEMA on the Flood Insurance Rate Maps, May 2005 and the area
of the floodplain located on the land mass within the City of Clearwater service
area. This hazard mitigation plan is concerned with floodplain area located within
the City's land mass.
The majority of resources devoted by the City to address stormwater
management deficiencies are aimed at the following four areas: the Coastal
Basins, which includes Clearwater Beach (Sand Key, North and South
Clearwater Beach and Island Estates) and the areas located adjacent to the
Tampa Bay and Clearwater Harbor; the Stevenson Creek drainage basin; the
Allen's Creek drainage basin and the Alligator Creek drainage basin.
These four locations receive an increased level of concern, as they contain much
of the City's land area and residential population. Other smaller areas of the City
located within the Bishop Creek, Curlew Creek, Jerry Branch, Lake Tarpon Canal
and Mullet Creek drainage basins also receive stormwater attenuation projects to
help alleviate flooding in those specific areas. Since the drainage basins span
municipal and county boundaries, Figure 2.0 shows the overall delineation of the
Southwest Florida Water Management District (SWFWMD) drainage basins
inside and outside the service area. Figure 3.0 illustrates the drainage basins
within the boundary of the City of Clearwater service area.
To minimize the loss of life, human suffering, damage to public and private
property, and economic loss, a complete knowledge of how flooding affects the
City of Clearwater, and the resources affected, must be determined. This hazard
identification and vulnerability assessment is a vital component to a citywide
floodplain mitigation plan. Through the information gathered, the City
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
will be better able to determine and prioritize mitigation initiatives used to prepare
for flooding episodes.
By developing a comprehensive assessment of the City's natural and man-made
resources and providing an analysis of how past flooding episodes affected these
resources, this flood mitigation plan will help to assure that the most beneficial
and cost effective flood mitigation activities are implemented by the City. Future
development potential within the City is illustrated in Figure 4.0, the City Zoning
Map, which is derived from the Pinellas County Future Land Use Map.
These land use categories provide a measurement of the maximum development
potential of current and future land use patterns. See Figure 5.0 for the Pinellas
County Future Land Use Boundaries Map.
General Description
The City of Clearwater is located in central Pinellas County along the west
central coast of Florida, bordered on the west by the Gulf of Mexico and the
Tampa Bay on the east. The city is bordered by the Cities of Dunedin to the north
and Safety Harbor to the east, the Town of Belleair and the Cities of Belleair
Beach and Largo to the south. The City of Clearwater has a total of 28-miles of
coastline.
Natural Features
The topography of the City of Clearwater can be characterized as nearly level to
a gently sloping terrain with the highest areas centrally located in the study area.
High coastal bluffs and white sandy beaches characterize the shoreline. Low
inland areas exist along the Allen's Creek, Alligator Creek and Stevenson Creek
floodplain. Elevations typically range from Mean Sea Level (m.s.!.) up to 104-feet
at its highest point (See Figure 6.0). The vegetation is typical of urban land in a
subtropical climate zone.
Drainage Basins
The City is divided into twelve drainage basins, of which four drain directly to the
Tampa Bay or the Gulf of Mexico. The 1 OO-year floodplain is represented in two
of these drainage basins. See Figure 7.0 for an illustration of the Flood
Insurance Zones, May 2005. All of the basins are multi-jurisdictional and include
unincorporated enclaves. As these basins span municipal and county
boundaries, an increased level of coordination is required among the government
entities involved in mitigation projects.
The Coastal Basin, Stevenson Creek, Alligator Creek and Allen's Creek drainage
basins are the four largest watersheds in the city. The three creeks
~ Clearwater
u ~ 9 S:\ESM\StafflAMcKinney\2009 JLOODPLAIN_MANAGEMENT]LAN\2009
FMP\2009 ylan _9_1_2009 Jinal.docx
Lake ChautauQua
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
drain an area several miles inland, and under specific conditions, tidewaters
generated at their mouths can inundate the creeks upstream and intensify
flooding episodes. See Figure 8.0 for the locations of creeks, lakes, and ponds.
In addition, the Bishop Creek, Curlew Creek, Jerry Branch, Lake Tarpon Canal,
and Mullet Creek drainage basins, all located in the northern portion of the City,
also function as stormwater runoff collectors. Refer to Figure 2.0 and 3.0 for
drainage basin locations. The Coastal Basin, the Stevenson Creek drainage
basin and the Alligator Creek drainage basin will be analyzed thoroughly in the
Repetitive Loss Property section, as these three areas contain repetitive loss
structures.
The Stevenson Creek Watershed, the largest and most urbanized watershed
within the City of Clearwater, drains 6,291-acres of land area in west central
Pinellas County; of this area, 4,605-acres (73%) are within the Clearwater city
limits. Bodies of water located within the Stevenson Creek Watershed are Lake
Bellevue, Lake Lucille, Crest Lake, and Hibiscus Lake.
At a total of 5,594-acres, of which 5,118-acres (91 %) are located within
Clearwater, the Alligator Creek Watershed is the second largest in the region and
most urbanized watershed in the City and includes a
complex basin consisting of four major lakes and seven
tributaries. Alligator Lake and Lake Chautauqua, at 78-
acres and 52-acres, respectively, are the largest interior
water body features located in the City. The two other
main lakes located in this watershed are Beckett Lake
and Harbor Lake.
The Allen's Creek Watershed is approximately 4,871-
acres in area. A total of 2,345-acres (48%) are
located within the south-central section of the City.
The majority of land uses located within this basin are
low-density single family residential. The main lakes
located within this watershed are Venus Lake, Lake
Starcrest, Lake Helen, and Sonny Lake.
At 908-acres, the Bishop Creek Watershed is the smallest basin with a portion of
its area located within Clearwater. The basin's land area within the City totals
just 214-acres (24%) and is located in the northeast section of the City. Nearly
one-third of the basin's land area functions as a school and the remaining uses
are medium-density residential and public/semi-public.
The Curlew Creek Watershed, located in the northern most section of the City,
drains 4,1 09-acres. With 1,390-acres (34%) of this watershed located within the
; tlearwater
o~
10
S :\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MAN AGEMENT ]LAN\2009
FMP\2009 -p1an_9 _1_2009 jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
City, it contributes to a significant drainage area for the overall stormwater
management system of the City.
While the majority of land uses located within this drainage basin function as a
mixture of residential density classifications, which vary from low- to high-density,
property fronting US Highway 19 North is classified as commercial and office.
Located in the north-central portion of the City, the Jerry Branch Watershed is
located between the Stevenson Creek, Alligator Creek, and Curlew Creek
Watersheds. At a total of 2,410-acres, 1,039 (43%) of which are located within
the City, the Jerry Branch drainage basin consists primarily of low- to medium-
density residential, with commercial uses sparsely found along the US Highway
19 and State Road 580 corridors.
The Lake Tarpon Canal Watershed provides a total drainage area of 1,782-acres
for the northeastern most section of the City and portions of Safety Harbor and
Oldsmar. Within the City of Clearwater, the basin totals 1,004-acres (56%).
Much of the area is devoted to low density residential, recreation/open space and
transportation utility uses.
At 1,928-acres, the Mullet Creek Watershed provides the neighboring City of
Safety Harbor with a significant area for stormwater retention. However, with just
581-acres (30%) of the drainage basin located within the City of Clearwater, the
basin manages a limited portion of the City's overall stormwater management
system. Mostly low-density residential land uses exist throughout the entire
drainage basin, while limited public/semipublic uses are located throughout and a
sparse amount of commercial uses are located along the McMullen Booth
corridor.
In addition to the above basins, some basins provide direct runoff to the Gulf of
Mexico, Tampa Bay, or Safety Harbor. These areas, labeled Direct Runoff to the
Gulf and Direct Runoff to the Bay, are shown on Figure 2.0. The Direct Runoff to
the Gulf Basin is the largest, 19,242-acres and includes all of the area known as
Clearwater Beach, as well as the western most portion of the City's mainland.
This western portion includes much of the area included in the City's Downtown
District and Harbor Oaks neighborhood. Figure 3.0 shows the separation of the
larger basin into Coastal Basin 1, Coastal Basin 3, and Coastal Basin Beach, a
total of 2179-acres (11 %) located within the City of Clearwater land mass. The
land uses located in the mainland portion of this basin range from low-density to
high-density residential, recreation/open space, commercial and public/semi-
public uses.
The main portion of Clearwater Beach is made-up of two natural barrier islands,
separated by an inlet that provides access to Clearwater Harbor (the Intra-
Coastal Waterway) and the Gulf of Mexico. These two barrier islands
~ Cllarwater
;;~
11
S :IESM\Staff\AMcKinney\2009 JLOO DPLAIN _MANAGEMENT ]LAN12009
FMPI2009 --p1an_9 _ I _2009 _final.docx
Island Estates
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
extend approximately six-miles along the Gulf of Mexico and consist of the areas
known as Clearwater Beach and Sand Key.
In addition to the two barrier islands, the area known as Island Estates is also
included in the basin. This man-made fill island, created
during the 1960's, contains approximately 210-acres and
10-miles of intra-coastal waterfront property consisting of a
series of islands and peninsulas. All of these areas are
densely populated and almost completely built-out. The
land uses consist of residential properties that vary from
single-family and multi-family condominium and town
homes, hotels and motels, commercial businesses, offices, parks and outdoor
recreation areas, churches and government buildings.
SWFWMD's Direct Runoff to the Bay basin is located along the eastern section
of the City and is 2,484 acres. The basin is separated into Coastal Basin 4 and
Coastal Basin 2 (See Figure 3.0) a total of 2,166 acres (10.5%) within the City
land mass. Coastal Basin 2 provides stormwater retention for various types of
land use in an area approximately east of Highway US 19 and south of State
Road 60. The land use in the basin ranges from low- to high-density residential,
recreation/open space, commercial, office, and public/semi-public. While much
of the basin's elevation does not exceed 30-feet, a small section in the western
most portion rises up to 80-feet.
Coastal Basin 4 located in the northeast area of the City consists primarily of low-
density residential uses.
Climate
The climate in Clearwater is subtropical marine, characterized by long, humid
summers and mild winters. Rainfall is abundant, especially during the summer
months. The annual average rainfall is 51.9 inches, mostly occurring between
June and September. The driest months of the year are April and November.
Snowfall in Clearwater is extremely rare. The maximum-recorded accumulation
was two inches in January 1977.
The average annual temperature is 74.1 degrees Fahrenheit. The average high
temperature is 81.7 degrees Fahrenheit, with an average low of 61.6 degrees
Fahrenheit.
In the winter months, the normal daily fluctuation in temperatures is from the low
50 degrees Fahrenheit to the low 70 degrees Fahrenheit.
; Clearwater
u~
12
S\ESM\S taff\AMcKinney\2009 JLOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 -p1an_9 _1_2009 _finaLdocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
In the summer months, the temperatures range from the low 70 degrees
Fahrenheit to the high 90 degrees Fahrenheit. The number of freezes recorded
at Tampa International Airport is an average of 3.3 days at 32 degrees
Fahrenheit or below per year. Due to Clearwater's exposure to the shoreline, the
average number of freezes tends to be less than those recorded in Tampa.
Clearwater has a very active thunderstorm season during the summer months.
There is an average of 85 thunderstorms per year. Most occur during the
months of June through September. The hurricane season extends from June
1st through November 30th.
Population
Clearwater is the second largest city in Pinellas County and has a population of
approximately 110,830 residents. The current population density is 4,336 people
per square mile. The average household size is 2.19 persons per home and the
average age of Clearwater residents is 41.3, with 25.6 percent of the population
over 60 years of age. Having a population base with 25.6 percent of the
residents over 60 years of age makes it very important to have an evacuation
program in place that considers the mobility limitations of the elderly. See Figure
9.0 for Hurricane Evacuation Level areas and Evacuation Routes.
Housing and Development
The City's total land mass is 20,640 acres. There are 25,611 residential parcels
containing 29,224 structures within the City. Of these, there are 4,547 parcels in
the floodplain, containing 6,048 structures with a total estimated improved value
of $3,467,270,300.
There are 1,321 commercial parcels containing 1,483 structures within the City.
Of these, there are 158 parcels in the floodplain containing 174 structures, with a
total estimated improved value of $155,971 ,800.
There are 644 office parcels containing 590 structures within the City. Of these,
there are 76 parcels in the floodplain containing 75 structures, with a total
estimated improved value of $52,393,200.
There are 1,431 tourist/downtown parcels containing 1,074 structures within the
City. Of these, there are 519 parcels in the floodplain containing 444 structures,
with a total estimated improved value 0 $953,094,900.
There are 233 industrial parcels containing 313 structures within the City. Of
~ Clearwater
u~
13
S\ESM\Staff\AMcKinney\2009 JLOODPLAIN _MAN A GEMENT _ PLAN\2009
FMP\2009 ylan _ 9_1_2009 Jinal.docx
14
S:\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
these, there are 46 parcels in the floodplain containing 80 structures, with a total
estimated improved value of $28,865,500.
There are 354 institutional parcels containing 737 structures within the City. Of
these, there are 96 parcels in the floodplain containing 207 structures, with an
estimated improved value of $126,201 ,800.
There are 153 open space I recreation parcels containing 128 structures within
the City. Of these, there are 97 parcels in the floodplain containing 91 structures,
with an estimated improved value of $25,110,800.
There are 45 parcels designated as preservation within the City. Of these, 32
parcels are located in the floodplain containing 9 structures, with an estimated
improved value of $5,914,700.
The existing residential character of the City is maintained with approximately
6,372-acres or 31 percent of the net land devoted to residential uses at a density
not exceeding 7.5 units per acre. Of this, 816-acres (4%) are located within the
floodplain. Generally, this density is not proposed to change.
Multi-family residential uses (7.6+ units per acre) occupy 2,686-acres or 13
percent of the City, of which 514-acres (2.5%) are located within the floodplain.
Mobile home parks occupy 357-acres (1.7%) of the City, of which 49-acres, or
0.2%, are located within the floodplain.
The majority of new multi-family residential development and redevelopment
projects are occurring on Clearwater Beach and Downtown Clearwater. Motels
located on Clearwater Beach are undergoing redevelopment to multi-family
residential uses on a parcel-by-parcel basis, while the redevelopment of
Downtown Clearwater is also occurring through infill projects on a parcel-by-
parcel basis. The mainly single-family residential area of north Clearwater Beach
is projected to remain low-density. New development and redevelopment is being
built within the permitted density and reviewed in detail for consistency with the
City's flood mitigation requirements.
All new residential development and redevelopment projects proposed within the
floodplain are required to be constructed to current FEMA requirements, limiting
potential flooding.
Development Constraints
1. Clearwater is surrounded by bodies of water to the east and west and no
large developable land areas to the north or south.
~ Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
2. Clearwater has experienced a 10.9 percent increase in population growth
since 1990, increasing from 98,784 to an estimated 110,830 in 2005.
3. There is limited vacant land within the entire City that is developable.
Within the floodplain, 197-acres (5.6%) of vacant land is available for
development.
4. Environmentally sensitive lands are designated Preservation and
Recreation/Open Space on the Clearwater Zoning Boundaries and
Drainage Basins Map (Figure 4).
Preservation and Recreation/Open Space future land use designations amount
to 31.3 percent of the floodplain and 11.0 percent of the entire City land area.
These designations do not permit residential or commercial development.
Despite these constraints, future development is still possible. Redevelopment of
existing properties and the annexation of additional properties currently located
outside of the municipal boundaries present future development opportunities for
the City.
Transportation
A network of state and local roadways service the City of Clearwater with U.S.
Highway 19, Alternate U.S. Highway 19, County Route 1 and County Route 611
providing the major north/south transportation corridors, while State Route 60,
State Road 580 and State Road 590 provide the major east/west transportation
corridors. The City is also serviced by a number of bus routes operated by PSTA,
the Pinellas Suncoast Transit Authority.
Identifying Hazards
Several hazards have been identified that pose a threat to the City's residents. It
was determined that the City of Clearwater is most vulnerable to the following
episodes:
· Tidal Flooding
. Hurricanes and Tropical Storms; and
. Seasonal Flooding.
While all three of these hazards pose a significant threat to the City's residents,
hurricanes and tropical storms are statistically the least likely to impact the City,
but would result in the most severe amount of damage.
; Clearwater
u~
15
S :IESMIStaft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT _ PLAN\2009
FMPI2009 ylan_9 _1_2009 _final.docx
16
S :IESMIS taff\AMcKinneyl2009 JLOO DPLAIN _MANAGEMENT ]LAN12009
FMPI2009 -plan _9_ I _2009_ final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Profiling Hazard Events
Flooding in the City of Clearwater results primarily from rain storms, tropical
storms and hurricanes that cause intense rainfall, excessive runoff and tidal
surge (and associated wave action) in coastal areas. Figure 10.0 provides the
Hurricane Storm Surge Areas located within the City. Although somewhat
protected from the Gulf of Mexico by the offshore islands, the coastline at the
City is subject to abnormally high storm tides. Not all storms that pass close to
the study area produce extremely high tides. Similarly, storms that produce
extreme conditions in one area may not necessarily produce critical conditions in
other parts of the study area.
Stevenson, Allen's and Alligator Creeks are coastal creeks that drain an area
several miles inland. Under certain conditions, tidewaters generated at the
mouths of these creeks can intrude far upstream. Strong consistent winds
associated with intense rain storms and tidal surges, which typically accompany
hurricanes, can aggravate the tidal flood situation, particularly in areas where the
secondary drainage system is poorly developed. Due largely to heavy seasonal
rainfalls and its location directly on the Gulf of Mexico, the City of Clearwater is
subject to periodic flooding and hurricanes. Storms passing in the vicinity of the
City have produced a number of major floods causing significant damage. A
historical review of the City's records from 1921 to 1972 revealed how major
storm events impacted the City.
The following list details these events.
. August 31-September 8, 1935 "Labor Day Hurricane"
This storm, called the "Labor Day Hurricane," was one of the most severe tropical
disturbances ever recorded. The storm was first located east of Turks Island,
traveled toward the Florida Straits, re-curved across the Florida Keys, and then
passed up the west coast of Florida on a broad re-curve that brought it inland
near Cedar Key. Along the beach areas from the City of Sarasota northward to
Clearwater Beach, homes were undermined and badly damaged. Mass
evacuation of those areas was accomplished before the storm.
. September 1-7,1950 "No-name Hurricane"
This hurricane originated over the western Caribbean Sea; passed northward
over Cuba and the Gulf of Mexico, then moved north-northwestward parallel to
the Florida coastline. It made two loops near Cedar Key, moved inland
southeastward, passed approximately 30 miles north of the City of Tampa,
recurved, and traveled northward. Pinellas County beach areas sustained heavy
damage, principally from the long duration of high tides and waves that caused
considerable erosion and recession of the shoreline. In turn, that erosion was
responsible for major structural damage along the beaches. This
(l~arwater
~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
small, but severe hurricane was also accompanied by intense rainfall. A total of
12.7 inches of rain in two days was reported in the City of Clearwater.
. June 4-14,1966 "Hurricane Alma"
Hurricane Alma originated in the Gulf of Honduras, passed between Dry
Tortugas and Key West, and landed in the Apalachee Bay area, causing variable
tides ranging up to 10-feet above normal on the west coast of Florida. Besides
structural damage in west Florida, the mango crop in the southwestern portion of
the state and the grapefruit crop around Pinellas County were severely damaged.
. June 19,1972 "Hurricane Agnes"
Hurricane Agnes originated on the northeastern tip of the Yucatan Peninsula and
traveled westward. The storm was of large diameter, and, although the center of
this storm passed approximately 150 miles west of the Florida peninsula, it
produced a high, damaging tidal surge. In Pinellas County, tides averaged 3 to 6-
feet above normal in the coastal areas. Beaches and causeways were flooded.
Flooding conditions of extreme magnitude occurred in Tampa Bay and caused
an influx of saltwater through the outlet canal into Lake Tarpon. Damage in
Pinellas County from this storm was estimated at $12.5 million.
A review of the flood insurance claims submitted within the City from 1978 to the
present indicates that the majority of claims resulted from the following four
storms and/or tidal events:
. August 31,1985 - September 4,1985 "Hurricane Elena"
Rainfall and high tides over a two-day period resulting in the flooding of 43
homes with insurance.
. September 6,1988 - September 9,1988 Stationary Front
Greater than 15 inches of rainfall in a four day period and high tides resulting in
the flooding of 15 homes with insurance.
. March 13, 1993 Winter No Name Storm
Rainfall and a tidal surge resulting in the flooding of 61 homes with insurance, the
worst event in terms of the number of claims.
. October 6, 1996 - October 8, 1996 Tropical Storm Josephine
Rainfall combined with high tides caused flooding in 32 homes with insurance.
The following list exhibits the dates identified by the NFIP that residents
submitted flood insurance claims following heavy rainfall and/or tidal events:
Date of Event Number of Claims
. May 4,1978 2
. May 8,1979
3
~~learwater
u~
17
S:\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --p1an_9 _1_ 2009 _fina1.docx
Clearwater
~
18
S :\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MAN AG EMENT ]LAN\2009
FMP\2009 ylan _9_1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
· August 29, 1979 1
. September 23-29, 1979 3
· February 8, 1981 1
· August 20 - 21, 1981 1
. February 8, 1981 1
· August9-10,1982 1
· June18,1982 9
. August 18-19, 1982 1
· February 28, 1983 1
· September 11, 1983 1
· September 29, 1984 1
· July 25-26, 1985 1
. August 31, 1985 43
· October 31, 1985 2
· December 31, 1986 1
. July 2,1987 1
. July 20-21, 1987 5
· September 6, 1988 15
· November 22-23, 1988 7
· January 2, 1990 6
. February 28, 1993 1
· March 12, 1993 61
. September 11, 1993 1
. October 4-5, 1995 5
· June 2-4, 1995 1
. July 11, 1995 1
· July 27, 1995 1
· October 7, 1996 32
. June 22-25, 1997 1
· July 5,1997 1
. October 31, 1997 1
· November 22, 1998 1
. January 2-3, 1999 5
. July 15, 2000 5
. December 9,2002 1
. February 22, 2004 1
Assessing Vulnerability
An assessment of the existing resources of the City is crucial to identifying the
vulnerabilities of an area. While it is highly important to understand the location
and demographics of the residential population living within the City,
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
an assessment of the built environment must also be available. A comprehensive
assessment will allow the City to fully understand where floodplain mitigation
strategies will most benefit the City's residents, as well as the built resources that
are critical to the welfare and safety of the residents. In addition, the assessment
needs to provide a description of the areas that are continuously flooded.
Identifying these areas and the structures that are affected by the repeated
flooding will allow the City to efficiently utilize the resources available to help
mitigate the impact of repetitive damages that occur to structures during flooding
episodes.
Residential Population
Identifying the existing number of residents living within the floodplain, as well as
the established hurricane evacuation levels, is crucial to the effectiveness of
understanding how to assess the floodplain management needs of the City. It is
essential that a coastal community establish the number and any age limitations
of residents living within the floodplain area to implement a successful mitigation
strategy.
The tables below identify the number of residents living within the specified Flood
Insurance Zones, established by FEMA, May 2005.
Population Living in Flood Insurance Zones
VE Zone AE Zone A Zone Total
3035 18,645 1,734 23,414
Special Facilities Populations
Home to a significant special needs population, 25.6 percent of the population
over 60 years of age, the City must take special considerations when developing
plans relating to pre-and post-disaster mitigation strategies. In addition,
individual facilities are required to develop hazard mitigation plans specific to the
facility. The table below illustrates the maximum capacity of hospitals, nursing
homes, assisted living facilities (ALF's), and ambulatory service centers (ASC's)
located within the City's Flood Insurance Zones and the maximum capacity at
each facility. See Figure 11.0 for Special Needs Facilities.
~ Clearwater
o~
19
S :\ES MIS taft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN12009
FMP12009 ylan _9_1_2009_ final.docx
Hos ital
Nursin Home
ALF
ASC
Total
1
6
39
3
49
o
1
4
o
5
120
53
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
S ecial Facilities Po ulation in Flood Insurance Zones
In the Cit Located in Flood lain
Total Total Max
Ca acit
173
Areas of Repetitive Loss Properties
Repetitive loss properties are properties that the National Flood Insurance
Program (NFIP) has paid two or more claims of $1,000 or more in any given 10-
year period since 1978. Since the inception of the CRS reporting system, 235
repetitive loss flood insurance claims have been made on 89 properties within
the City, amounting to $4,196,871 in flood insurance compensation (NFIP,
Repetitive Loss Details by Community, June 30, 2007). See Figure 12.0 for
current repetitive loss property locations as of June 30, 2007. The following
section provides an assessment of the reoccurring flood problems and includes
the number of repetitive loss properties, the primary existing land uses, and a
description of the area. Clearwater Beach and Stevenson Creek contain the
majority of repetitive loss claims. Alligator Creek has only five repetitive loss
properties located within its basin.
Coastal Basin
At approximately 2179-acres, the Coastal Basin contains more than half (62%) of
the City's land area located within the 1 OO-year floodplain. The 65 repetitive loss
properties located on Clearwater Beach, eight of which are located on Sand Key
and one on Island Estates, represents 80 percent of the total for the City. Since
the inception of the National Flood Insurance Program, these 74 properties have
produced 192 flood insurance claims, 76 percent of the total claims for the City,
that have amounted to $3,151,860.00 in insurance payments. Land uses within
the Clearwater Beach area are residential and commercial. Many of the
commercial facilities are hotels, motels, restaurants and retail shops catering to
the tourist population. The Island Estates neighborhood and the fingers off
Hamden Drive on Clearwater Beach and Gulf Boulevard along Sand Key were
created through fill activities.
Storm outfalls below mean high tide, lower than desirable building finish floor
elevations and the topography of these areas are all contributing factors to the
repetitive losses, generally caused by tidal flooding. The highest benchmark, 7.4-
feet above m.s.1. NGVD29, on Clearwater Beach is located along the
~ €learwater
(j~
20
S :IESMIStafflAMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMPI2009 -p1an_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Memorial Causeway at Island Way in Island Estates. The beach watershed was
first studied and addressed in the 1997 Clearwater Watershed Action Plan. A
high percentage of impervious acreage, increased channelization and a
decreased headwater depressional storage area have contributed to flooding
problems, which are typical of highly developed urban areas.
Stevenson Creek Basin
There are 10 repetitive loss properties located in the Stevenson Creek Basin.
Since the inception of the National Flood Insurance Program, these 10 properties
have produced 29 flood insurance claims, which amounted to $207,188 in
insurance payments. The Stevenson Creek watershed is highly urbanized with
less than 10 percent of the land area undeveloped. The predominant land use in
this watershed within Clearwater City limits is low-density residential particularly
east of Stevenson Creek and north of Drew Street. Land use west of Stevenson
Creek and south of Drew Street is comprised of mixed urban land uses including
low-density residential, high-density residential, commercial, overnight
accommodations, office and industrial. The Stevenson Creek basin is shared
with the cities of Dunedin, Largo and Pinellas County. The main lakes located
within the watershed, and limits of the City of Clearwater, include Lake Bellevue
(24-acres), Crest Lake (10-acres) and Lake Hobart (12-acres). Lake Bellevue
and Crest Lake are adjacent to low-density residential and recreational uses,
while a large area of low-density residential land use surrounds Lake Hobart.
The gently rolling topography of the Stevenson Creek watershed varies in
elevation from zero to 65 feet above mean sea level. Dense development has
resulted in extensive impervious surfaces and very limited amounts of natural
stream and floodplains. Most constructed channels are inadequate for heavy
storm runoff and are further restricted by small bridges and culverts, which
frequently cross the creek.
Historically, the Stevenson Creek watershed provided
different habitats found in Florida. The mouth of the
creek is estuarine. A weir, constructed at Palmetto
Street along the creek, separates the saltwater
portion from the freshwater portion. South of the
weir, the banks are relatively steep and create only a
small zone for wetland vegetation. This extends to
Court Street, where the creek runs through the Glen
Oaks Municipal Golf Course. Vertical walls confine
the southern end before opening up into a wider
expanse of exotic and nuisance species of vegetation.
examples of many
Stevenson Creek at the Pinellas
Trail
~ Clearwater
;;~
21
S\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 --plan _9 _1_2009 _finaldocx
Nearly 90 percent of the drainage area is within the Clearwater City limits. The
main stem of Alligator Creek originates near the intersection of Keene Road and
Sunset Point Road on the northern edge of a large industrial area adjacent to the
Clearwater Airpark. There are five defined tributaries
which discharge to the main Alligator Creek channel.
The main channel flows easterly, eventually discharging
to Alligator Lake, which in turn discharges into Old
Tampa Bay. Alligator Lake is fitted with a salinity
control structure, which prevents saltwater intrusion into
the lake. Significant lakes within the watershed include
Alligator Lake (80-acres); Lake Chautauqua (50-acres);
and Moccasin Lake (3D-acres). Lake Moccasin Lake
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The stream is controlled by a weir at Druid Road and functions as a long linear
retention area south of Druid Road to Jeffords Street. South of Jeffords Street, a
significant amount of aquatic vegetation occurs in the stream way with wetland
vegetation confined to a narrow bank zone in this channelized section. From
Lakeview Road and beyond, the stream channel is confined to a narrow
easement and is overgrown with exotic and nuisance species until the stream is
piped underground at Bellevue Boulevard.
Several studies have been conducted on the Stevenson Creek watershed over
the last 15 years including two watershed management plans. New projects are
implemented as a result of the latest watershed management plan and as the
projects are completed the City of Clearwater Engineering Department
proactively updates the plan to reflect the mitigation activities.
Alligator Creek Basin
There are five repetitive loss properties in the Alligator Creek watershed, which
have produced 14 flood insurance claims that have amounted to $837,823 in
insurance payments.
The Alligator Creek watershed lies within three
jurisdictions, including the City of Clearwater, Pinellas
County and the City of Safety Harbor. This is the most
urbanized watershed in the City, with a large industrial
area covering the western portion, low density residential
areas in the central portions and a wide corridor of
commercial land use along U.S. Highway 19 and Gulf-to
Alligator Creek Bay Boulevard. The Alligator Creek watershed is the
second largest watershed within the City of Clearwater
and drains approximately 5,594-acres.
; ~learwater
u~
22
S :\ES M\Staft\AMcKinney\2009 JLOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 -plan _9_ I _2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Chautauqua discharges into a south flowing tributary of the main channel.
Moccasin Lake is located almost centrally along the length of the stream at
Moccasin Lake Park. Runoff is received from the surrounding areas and the lake,
as well as two retention ponds which outfall into a channel and subsequently into
the main channel. Alligator Lake is the most downstream lake in the Alligator
Creek watershed and receives runoff from the entire upstream portion of the
watershed as well as from local residential runoff.
The topography of Alligator Creek is the most dramatic of Clearwater's basins in
that it contains two relatively large areas within its northern region with elevations
over 90 feet, as well as areas within the eastern region that are just above sea-
level. The creek has two main areas of headwaters within the City; one is located
in a topographically high area north of Lake Chautauqua (90-feet above m.s.I.)
and the other is located west of Keene Road (55-feet above m.s.I.).
Several studies have been performed for the Alligator Creek basin over the past
15 years. The first of these studies was conducted in 1981 by HDR for Pinellas
County as part of a countywide comprehensive stormwater drainage master plan.
The U.S. Army Corp of Engineers conducted a detailed study in a portion of the
basin for the City of Clearwater in 1989. In 1997, Parsons Engineering Science,
Inc. performed the most comprehensive study for this basin, and updated the
study in 2005.
There are no repetitive loss properties in the other drainage basins (Allen's
Creek, Bishop Creek, Curlew Creek, Jerry Branch, Lake Tarpon Canal and
Mullet Creek) located within the City.
Identifying Assets
Existing Floodplain Land Uses
The City's floodplain is primarily a mix of single-family and multi-family residential
uses, open space/recreation and preservation, with limited commercial and
industrial uses. Residential land uses (40%) and land designated as
preservation or recreation/open space (31 %) account for 2472-acres (71 %) of
the floodplain. Much of the City's 1 OO-year floodplain is located along the coastal
areas, and at 1130-acres, Clearwater Beach encompasses less than half of the
City's entire floodplain area. See Figure 7.0 for special flood hazard areas. Due
to the natural beauty and recreational opportunities offered by the beach, much
of the Clearwater Beach area is utilized for residential and/or tourist purposes.
The existing land use data analysis shows both positive and negative trends. The
limited amount of land utilized for non-residential purposes (29.1 %) and the
abundant amount of preservation and recreation/open space land uses (31.4%)
within the floodplain shows an encouraging trend. With approximately
~~learwater
u~
23
S\ESM\StafflAMcKinney\2009 JLOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 ylan _9_1_2009 Jinal.docx
~(learwater
0~
24
S :\ESM\Staff\AMcKinney\2009 ]LOO DPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
one-third of a city's land area located within the floodplain utilized for residential
purposes, the importance of the City's continued participation in the pre- and
post-flood hazard programs offered by the Federal government and flood
mitigation planning at the local, regional and state level is reinforced.
An analysis of existing floodplain land uses results in the following findings:
1. 17.0 percent (3,487-acres) of the City land mass is located within the 100-
year floodplain.
2. Residentially developed land within the floodplain totals 1,379-acres
(40.0%), approximately 4,547 residential parcels, containing 6,048
structures.
3. Within the floodplain, 1,093-acres (31.4%) are designated as preservation
or utilized as recreation/open space land uses.
4. Only 651-acres (18.7%) of land area is utilized as commercial, office,
downtown, tourist, mixed-use, industrial and institutional purposes.
5. 197-acres (5.6%) of land located within the floodplain is currently vacant.
Existing floodplain land uses are inventoried and summarized in the table below.
land Use Acres Percent
land Use Type Total Acres in Floodplain % of Floodplain
Residential 1,379 39.5
Commercial/Retail 143 4.1
Office 43 1.2
Tourist / Downtown 239 6.9
Industrial 59 1.7
Institutional 167 4.8
Recreation/Open Space 682 19.6
Preservation 411 11.8
Vacant 197 5.6
Unincorporated 167 4.8
TOTAL 3487 100
Annexation Areas
There is approximately 4,1 08-acres of unincorporated county land located within
the Clearwater's Planning Area, most of which are developed. Only 167 -acres of
unincorporated land exists in the floodplain and is not a concentrated
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
area, but rather a scattered throughout the central portions of the City.
Unincorporated land located within the floodplain exists primarily as low- and
medium density single-residential uses.
Clearwater has a voluntary annexation program that encourages properties
located within the Clearwater Planning Area to annex into the City. The
annexation program is governed under the Pinellas County Ordinance 00-63 and
Florida Statutes, Chapter 171.
Critical Facilities
A critical facility is defined as a facility in either the public or private sector that
provides essential products and services to the general public, is otherwise
necessary to preserve the welfare and quality of life in the City, or fulfills
important public safety, emergency response, and/or disaster recovery functions.
The critical facilities identified in the City include storm shelters, hospitals and
other health care facilities; municipal, county, state and federal government
buildings; airports; gas, electric and communication utilities; water and
wastewater treatment plants; hazardous waste sites; and schools. The following
list exhibits the figures that reference each of the critical facilities:
· Figure 13.0, Critical Facilities (Fire Stations; Police Stations; Hospitals;
Shelters; Special Needs Shelters; Airports; Hazardous Material Storage
Sites)
· Figure 14.0, Sanitary Sewer Facilities
· Figure 15.0, Natural Gas Infrastructure
· Figure 16.0, Public and Private School Facilities
The following table exhibits the number, of the critical facilities located throughout
the entire city, as well as the facilities located within the floodplain.
C"f IF T"
h FI d I "
rI Ica aCI Itles m t e 00 IPI am
# in the
TYPE OF FACILITY # in the City Floodplain
Fire Stations 8 2
Police Stations 9 3
Hospitals 1 0
Storm/Emergency Shelters 4 0
Airports 1 0
Hazardous Material Storage 18 5
Site
Total 52 10
; Clearwater
ij~
25
S :\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMP\2009 ylan_9 _1_2009 JinaLdocx
Prospect Lake Park
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
SECTION 4.0 HAZARD MITIGATION STRATEGY
Three departments within the City's administration guide stormwater
management. The Engineering Department is responsible for identifying
problems and implementing solutions. The Pubic Services Department is
responsible for maintenance of public drainage systems. The Planning and
Development Department, in conjunction with the Engineering Department, are
responsible for the review and approval of private drainage conveyance and
retention. An engineer with the Engineering Department currently serves as the
CRS coordinator. Since its incorporation in the NFIP, the City has been involved
with stormwater management and reduction of flood damages, and the planning,
design and construction of drainage improvements. Historically, the 1981
Alligator Creek Drainage Basin Study and the 1981 Stevenson Creek Drainage
Basin Study, and the subsequent updates, have guided flood management and
built a foundation for implementing mitigation projects.
The Clearwater Comprehensive Plan (2001), the Watershed Action Plan (1997),
the Allen's Creek Watershed Management Plan (1996), the Alligator Creek
Watershed Management Plan (1997) and Update (2005) and the Stevenson
Creek Watershed Management Plan (2001) have guided recent stormwater
management activity. As the projects identified from these studies are
implemented, the plans are updated to include the mitigation activity. Numerous
other supplemental studies have also been completed to address the City's flood
prone areas. As a result of the planning efforts and mitigation projects identified
by the watershed management plans, the City created the Capital Improvement
Stormwater Management Committee (CISMC) to efficiently address effective
stormwater management strategies. The CISMC, comprised of City
representatives from the Engineering and Public Service Departments, regularly
convenes to discuss various issue related to stormwater policy and to address
any deficiencies in the City's Stormwater Management system.
Evaluation of Previous Plan's Activities
Several activities identified through the 2004 version of the Floodplain
Management Plan have been, or are in the process of being implemented. Many
of these activities are continuously updated and are also included in this Plan.
The following is a list of activities and projects identified through the 2004 Plan
that have been completed:
. Kapok Land Acquisition and Restoration Analysis
. Prospect Lake Park (Town Pond) Construction
. Moccasin Lake Habitat Improvement Feasibility
. Stevenson Creek Stormwater Retrofit Project
. North Greenwood Neighborhood Stormwater Project
. Myrtle Avenue Drainage Improvements
Clearwater
~
26
S :\ESM\Staft\AMcKinney\2009 JLOO DPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_ I _2009 jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwa ter
Floodplain Management Plan
. Palmetto Street Drainage Improvements
. Glen Oaks Phase I and II Stormwater and Recreation Improvements
. Alligator Creek Channel B
. Alligator Creek Channel G
. North Beach Drainage Improvements
. NE Coachman Road Bridge Assessment
On-going activities and projects identified through the 2004 version of the Plan
are also referenced in the "Identification and Analysis of Mitigation Measures"
section included in this Plan. The City will continue to monitor the progress of
these ongoing projects to help alleviate the impacts of flooding on residents.
Current and future projects and activities are also identified in this Plan.
Floodplain Regulations
The extent of the flood hazard exposure in developed floodplain areas is largely
due to construction below the 1 DO-year base flood elevation. These properties
are referred to as pre-FIRM because of their construction before the adoption of
Flood Insurance Rate Maps (FIRM) requiring construction above flood elevation.
Formal regulation of floodplain development did not occur until 1980 when the
Flood Damage Prevention Ordinance was passed. The Flood Damage
Prevention Ordinance (Appendix D), contained in the Clearwater Community
Code, regulates coastal construction in all areas of special flood hazard,
consistent with 161 Florida Statutes and the National Flood Insurance Program.
The Ordinance refers to the Federal Emergency Management Agency's (FEMA)
maps in defining the coastal high hazard area. Special construction standards
are required for new development, substantial improvements and the facilities
that service areas vulnerable to flooding. The standards are intended to
minimize impacts on natural features and allow structures to withstand the effects
of a 1 DO-year storm. The majority (58) of the 89 repetitive loss properties are
located on Clearwater Beach, constructed prior to FEMA's current base flood
elevation requirements. Base flood elevation requirements for the North
Clearwater Beach area are generally 11 feet NAVD88. Article 4, Division 13 of
the Clearwater Community Development Code provides strict requirements for
the process of land clearing and grubbing (Appendix E). This section requires
that specific procedures are met prior to the issuance of a permit to clear land
within the City.
The Erosion and Siltation Control Policy was implemented in 1984, and amended
in April 2003 (Appendix F). These measures require erosion and siltation control
methods to be employed during construction. This policy includes measures
such as land clearing and grubbing, stabilization of denuded areas, protection
~ tlearwater
u~
27
S :\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MAN AGEMENT _ PLAN\2009
FMP\2009 ylan _9 _1_2009 _final.docx
28
S\ES M\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -p1an_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
and stabilization of soil stockpiles, protection of existing storm sewer systems
and sediment trapping procedures.
The Design Criteria for Stormwater Drainage was implemented in 1991 and
revised July 2000 (Appendix G). In general, these standards are requirements
set by the Southwest Florida Water Management District and the City of
Clearwater Engineering Department. This document prevents damage from
flooding by reducing peak flows of surface water runoff and ensures water quality
by managing the concentration of pollutants entering surface waters.
The City also utilizes a Stormwater Management System Policy 2002 guidance
manual (Appendix H). This manual is intended to provide water policy guidance
for the development and implementation of programs, projects, rules and plans
relating to City water resources. This manual also establishes the policies and
goals by the City's Engineering Department to address floodplain management.
The Tampa Bay Estuary Program (TBEP) was established in 1991 to assist the
community in developing a comprehensive plan to restore and protect Tampa
Bay. The program is part of a national network of 28 estuary programs
established under the Clean Water Act and administered nationally by the U.S.
Environmental Protection Agency (EPA). Local administrative support is provided
through the Tampa Bay Regional Planning Council. Charting the Course - The
Comprehensive Conservation and Management Plan (CCMP) for Tampa Bay,
provides strategies to repair and protect the Tampa Bay ecosystem in the most
cost-effective manner and according to the principles of ecosystem management.
Clearwater is a TBEP participant and has created an action plan to meet the
goals of the CCMP.
Identification and Analysis of Mitigation Measures
The City of Clearwater has completed and will continue to implement floodplain
management activities that are ongoing, as well as propose new projects. These
fall into the CRS Floodplain Management Activities: planning goals, preventive
activities, property protection, natural resource protection, emergency services,
public information and stormwater management projects. The following activities
were previously identified through meetings with city staff, the flood protection
surveys, coordination with other local, regional and state agencies and the review
of previous City reports and documents. These goals and activities listed below
represent those that would provide the greatest level of hazard reduction to the
City. The City will continue to implement these goals as well as add new goals
through update of this Plan.
Plannina Goals
Planning goals appropriate to the Floodplain Management Plan have been
adopted as part of the City of Clearwater's Comprehensive Plan.
~ Clearwater
ij~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
These community policies have been implemented, will be implemented, or are
ongoing, and are found in the Future Land Use, Coastal Management,
Conservation, Recreation and Open Space, Intergovernmental Coordination, and
Capital Improvement Elements, and the Stormwater Subelement. The evaluation
of these goals is an on-going process. A comprehensive review was conducted
in 2006 through the City's Evaluation and Appraisal Report (EAR) process.
Selected goals directly associated with the mitigation of flooding activities and the
protection of property from flood episodes are provided below.
A. Future Land Use Element
Policy 1.1.5 Stormwater shall be controlled through consistent application of
local, state, and federal regulations, mitigation and management plans, and
permitting procedures for both site-specific and basin-level development
plans.
Policy 1.1.6 All development and/or redevelopment activities in f100dways and
floodplains shall be controlled through consistent application of local, state,
and federal regulations, mitigation and management plans, and the permitting
process.
Policy 1.1.7 New development or redevelopment in the Coastal High Hazard
Area shall be permitted consistent with F.E.M.A. and City Guidelines.
Policy 1.1.8 Mitigation plans for alteration of non-jurisdictional wetlands,
beach dunes, swamps, marshes, streams, creeks, one hundred (100) year
flood plains, or lakes shall require not less than a 1: 1 ratio of mitigation land
(on- or off-site) as approved by the Engineering Department and/or City
Council, and in coordination with the Southwest Florida Water Management
District (SWFWMD).
Policy 1.1.9 The effects of erosion shall be carefully controlled through local
permitting and construction standards, procedures and regulations, and
through the development of local and regional erosion control management
programs.
Policy 1.1.10 The Community Development Code shall provide for on-site
drainage detention and/or retention or payment in lieu thereof for compatibility
with community master drainage plans.
1.2 Objective - Population densities in the coastal storm areas are restricted to
the maximum density allowed by the Countywide Future Land Use
Designation of the property, except for specific areas identified in Beach by
Design: A preliminary Design for Clearwater Beach and Design Guidelines, in
which case densities identified in Beach by Design shall govern. All
(Iiarwater
~
29
S :\ESM\Staft\AMcKinney\2009 ]LOO DPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 ylan _9_1_2009 _final.docx
u~
30
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 Jinaldocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
densities in the coastal storm area and shall be consistent with the Pine lias
County Comprehensive Emergency Management Plan and the Regional
Hurricane Evacuation Study.
Policy 1.2.1 The City shall require new or redeveloped overnight
accommodations uses located within the City's coastal storm area to have a
hurricane evacuation plan, approved by the City, for all guests. This plan shall
require the commencement of evacuation of hotel guests as soon as a
hurricane watch is posted for the City.
Policy 1.2.2 Continue to cooperate with the Tampa Bay Regional Planning
Council and Pinellas County to meet the regional objectives for evacuation of
permanent populations as well as other emergency concerns.
Policy 2.2.2 Residential land uses shall be appropriately located on local and
minor collector streets; if appropriately buffered; they may be located on
major collector and arterial streets. Residential land uses shall be sited on
well-drained soils, in proximity to parks, schools, mass transit and other
neighborhood-serving land uses.
Policy 4.1.1 No new development or redevelopment will be permitted which
causes the level of City services (roads, recreation and open space, water,
sewage treatment, garbage collection, public school facilities, and drainage)
to fall below minimum acceptable levels. However, development orders may
be phased or otherwise modified consistent with provisions of the
concurrency management system to allow services to be upgraded
concurrently with the impacts of development.
B. Stormwater Management Subelement 0.3 (See Appendix I for entire
Subelement 0.3)
Policy 0.3.2.3 All stormwater management improvements should seek to
meet applicable goals, guidelines, and regulations established to provide
flood protection and pollution abatement.
0.3.3 Objective Lower highwater profiles during storm events, as necessary,
to reduce house-flooding occurrences and to lessen the resulting adverse
effects on public health, the natural environment, and public and private
property.
Policy 0.3.3.1 Continue to provide a program of regular maintenance to the
stormwater management system to ensure maximum efficiency and
performance. Ensure that stormwater management plans include measures
to remove trash, sedimentation and other debris which impede flow and
incorporate structural and non-structural measures to reduce or
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
eliminate the discharge of oil, grease, heavy metals, and other suspended
particles into the stormwater management systems.
Policy 0.3.3.2 Natural and man-made wetlands shall be considered as a
means to provide stormwater management wherever possible and shall be
maintained for hydrologic purposes. The efficiency of natural and man-made
systems to convey stormwater runoff shall be protected through the provision
of routine water quality maintenance schedules overseen by city inspections.
Policy 0.3.3.3 Continue to provide multiple use facilities, such as
recreational open space uses, with open channel stormwater management
systems, when appropriate.
Policy 0.3.3.4 Development and redevelopment activities shall comply with
all stormwater management design standards and criteria.
Policy 0.3.3.5 Structural Development shall be prohibited where it is
determined that such development will have an adverse impact on
stormwater storage areas, increase flood prone areas, significantly increase
rates of runoff, or cause other unfavorable drainage conditions. Both man-
made and natural systems shall be treated on an equal basis as a sensitive
preservation area; no distinction shall be made between a natural system and
a man-made or man altered hydrologic system.
Policy 0.3.3.6 Limit development that will result in building(s) constructed
within/or over stormwater retention/detention ponds, streams or channels. All
wetlands, streams, channels, or other hydrologic features, whether wetlands,
ponds or bodies of water having intrinsic hydrologic, biologic and zoological
functions with no distinction made in regard to its status to whether it is man-
made or natural shall be considered for a Preservation Land Use Plan
classification to ensure protection from development.
Policy 0.3.3. 7 Continue active participation and cooperation with the
National Flood Insurance Program and the Florida Emergency Management
Agency for the purpose of recognizing flood prone areas, and establishing
abatement programs that endeavor toward a reduction in damages and
losses due to flooding.
Policy 0.3.3.8 Continue the established requirement of a twenty-five foot
setback from the tops of a bank from all wetlands whether natural or man-
made, and require minimum finished floor elevations in areas adjacent to
lakes, bays, creeks, the Gulf of Mexico, Tampa Bay and Old Tampa Bay, and
other flood prone areas.
; Clearwater
u~
31
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 -'plan _9 _1_2009 jinal.docx
>
G~
rwater
32
S:IESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN12009
FMPI2009 "'plan _9_1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
0.3.4 Objective Continue the implementation of the most cost effective and
efficient plan to reduce the occurrence of street flooding where safety issues
and traffic problems exist as prioritized and set forth in the Capital
Improvement Element, and listed in the stormwater management plans.
Policy 0. 3.4. 1 Identify areas where inadequate stormwater management
easements exist, and obtain proper access to stormwater management
channels, structures and appurtenances for maintenance purposes.
Policy 0.3.4.2 Improve all street stormwater management systems where
deficiencies exist as articulated in the City's annual budget document.
Policy 0.3.5 Objective - Protect and enhance the quality of receiving
waters by the use of "Best Management Practices" in accordance with the
adopted watershed management plans.
Policy 0.3.5.1 The use of "best management practices" shall be required
before, during, and after construction activities to prevent water pollution
resulting from erosion and siltation.
Policy 0.3.5.4 Maximize water recharge potential in designing stormwater
management improvements by utilizing natural wetland areas for stormwater
storage.
Policy 0.3.5.5 Coordinate stormwater management improvements with
other local governments to assist in solving stormwater management
problems of an extraterritorial nature.
0.4 GOAL - STORMWA TER DISCHARGE SHALL BE MANAGED TO
PROVIDE FLOOD PROTECTION FOR THE CITIZENS OF THE CITY OF
CLEARWATER AND TO PRESERVE, PROTECT, AND ENHANCE THE
WATER QUALITY OF RECEIVING WATERBODIES.
0.4.1 Objective - The protection, restoration, and enhancement of water
quality associated with stormwater runoff will be considered a function of the
City's overall stormwater management plans.
Policy 0.4. 1. 1 The City shall incorporate water quality protection and
enhancement criteria into the City stormwater management plans.
Policy 0.4.1.2 The use of natural alternatives, the conservation of natural
stormwater management systems, and the protection and improvement of the
quality of receiving waters shall be a goal of the City's stormwater
management plans.
~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Policy 0.4. 1.3 Management plans shall continue to be developed on an
ongoing basis for waterbodies with known or suspected water quality
problems in the City to include Tampa Bay, Clearwater Harbor, Stevenson
Creek, Allen's Creek, and Alligator Creek.
Policy 0.4.1.4 The City shall systematically and timely prepare watershed
or waterbody specific management plans, and update them as necessary for
waterbodies within the City. Such plans shall include both water quality and
flood control considerations and recommended funding sources.
Policy 0.4. 1.5 The City shall implement all City-approved watershed
management plans.
Policy 0.4.1.6 All City stormwater management plan projects within
watersheds of the City shall comply with applicable SWFWMD, State, and
Federal requirements, including SWIM Plans for that waterbody or watershed.
Policy 0.4.1. 7 The City shall continue to coordinate with and supplement
the County's surface water monitoring program.
C. Coastal Management Element
E.1.1 Objective - Clearwater shall continue to protect beaches and dunes by
use of the State Coastal Construction Control Line as the building and land
alteration setback line for purposes of administering the Community
Development Code. The Florida Building Code, Federal Emergency
Management Agency (FEMA) regulations, and City coastal construction
regulations will continue to govern the structural integrity of new buildings.
1.2 Objective The coastal storm area shall be the area delineated in Map E-1
of the Coastal Management Element, which encompasses all of the following:
(1) the Coastal High Hazard Area (CHHA), which shall be defined by the sea,
Lake and Overland Surges from Hurricanes (SLOSH) model to be inundated
from a category one hurricane, as reflected in the most recent Regional
Evacuation Study, Storm Tide Atlas,
(2) all land connected to the mainland of Clearwater by bridges or causeways
(3) those isolated areas that are defined by the SLOSH model to be
inundated by a category two hurricane or above and that are surrounded by
the CHHA or by the CHHA and a body of water, and
(4) all land located within the Velocity Zone as designated by the Federal
Emergency Management Agency.
~Glearwater
u~
33
S :\ESM\Staft\AMcKinney\2009 ]LOO DPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 -pI an_ 9 _1_2009 _finaldocx
; Clearwater
o~
34
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --p1an_9 _1_ 2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The City shall direct permanent population concentrations away from the
coastal storm area consistent with the goals, objectives and policies of the
Clearwater Comprehensive Plan.
Policy E.1.2.2 Clearwater shall continue hazard mitigation by participation in
the National Flood Insurance Program's (NFIP) Community Rating System,
Pinellas County's Local Mitigation Strategy, administration of building and
rebuilding regulations consistent with City and FEMA regulations, prohibition
of beach sand dune alteration, and restriction of development in flood plains.
Policy E. 1.2.3 The City will encourage natural hazard mitigation actions
recommended by any interagency hazard report that the City deems
appropriate.
Policy E.1.2.4 General hazard mitigation will be encouraged to include the
regulation of building practices, floodplains, beach and dune alteration,
stormwater management, sanitary sewer and septic tanks, and land use to
reduce the exposure of human life and public and private property to natural
hazards; and appropriate recommendation from the Pinellas County Local
Mitigation Strategy will be incorporated into the Clearwater Comprehensive
Plan.
Policy E.1.2.5 The City shall prohibit the location of new hospitals, nursing
homes and assisted living facilities in the Coastal Storm Area and the area
inundated by a category 2 hurricane as depicted by the SLOSH model, as
reflected in the most recent Regional Evacuation Study, Storm Tide Atlas.
Policy E.1.6.1 Redevelopment proposals and plans shall be reviewed for
compliance with the goals, objectives and policies of the Comprehensive Plan
and other appropriate plans including Beach by Design: A Preliminary Design
for Clearwater Beach and Design Guidelines and the City's NFIP Community
Rating System Floodplain Management Plan.
Policy E.2.1 Objective - The City shall continue to protect coastal wetlands,
estuaries and wildlife habitats to maintain or increase the acreage for
threatened and endangered species populations.
Policy E.2.1.1 Restoration and enhancement of disturbed or degraded
estuaries identified by the Surface Water Improvement and Management
(SWIM) program shall be accomplished by strict regulation of proposed
impacts to wetlands and by controls on the operation and installation of
marinas and other water-dependent uses.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Policy E.2.1.2 Development applications shall be reviewed to ensure that
proposed new development or redevelopment will not encroach on or remove
wetlands or beaches. New development and redevelopment shall be guided
away from environmentally sensitive areas and into those most able to
withstand impacts.
Policy E.2.1.3 Marina siting criteria shall restrict marinas and related activities
from areas of environmental significance, which include but are not limited to
the north end of Clearwater Beach, grass beds in Clearwater Harbor,
Cooper's Point, and Clearwater Harbor Spoil Islands 25, Sand Key Park, and
the southern edge of Alligator Lake. Marinas shall only be allowed in these
areas with appropriate and approved mitigation.
Policy E.2.1.4 The City shall work toward reducing the existing quantity and
improving the quality of stormwater runoff to estuarine and surface water
bodies by ensuring that development and redevelopment adheres to the
treatment standards set forth in State Water Policy, and complies with the
retention and treatment requirements of Chapter 62-25 F.A.C., the
Environmental Resource Permitting Rules 400-4,400-40,400-400, F.A.C. of
the Southwest Florida Water Management District (SWFWMD) and with any
more stringent local regulations.
Policy E.2.1.5 The City shall proactively pursue and facilitate coordination and
participation in the implementation of the Tampa Bay Estuary Comprehensive
Conservation and Management Plan (CCMP), and related plans, as a means
of achieving mutual local and regional resource management and restoration
goals for Tampa Bay.
Policy E.2.1.6 The City shall permit passive recreation uses in appropriate
coastal areas as identified in the Future Land Use Element of the
Comprehensive Plan.
Policy E.2.1.7 The City shall coordinate with Pine lias County and other local
governments for water quality monitoring and related program planning.
Policy E.2.1.8 Future land uses which are incompatible with the protection
and conservation of wetlands and wetland functions shall be directed away
from wetlands.
Policy E.2.1.9 The type, intensity or density, extent, distribution and location
of allowable land uses and the types, values, functions, sizes, conditions and
locations of wetlands are land use factors, which shall be considered when
directing incompatible land use away from wetlands.
~Clearwater
u~
35
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --plan _ 9 _1_2009 Jinaldocx
36
S :\ESMlS taftlAMcKinney\2009 _FLOODPLAIN_MAN AGEMENT _PLAN\2009
FMP\2009 ylan _9_1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Policy E.2.1. 10 Land uses shall be distributed in a manner that minimizes the
effect and impact on wetlands. The protection and conservation of wetlands
by the direction of incompatible land uses away from wetlands shall occur in
combination with other goals, objectives and policies in the comprehensive
plan. Where incompatible land uses are allowed to occur, mitigation shall be
considered as one means to compensate for loss of wetlands functions.
Policy E.2.2 Objective - Clearwater's barrier islands include natural resources
which shall be preserved from encroachment and development.
Policy E.2.2.1 Restoration and enhancement of disturbed or degraded dune
and beach areas shall be implemented with the appropriate methods and
quality of material necessary to enable successful reestablishment.
Policy E.2.2.2 The specific and cumulative impacts of development and
redevelopment upon wetlands, water quality, water quantity, wildlife habitat,
and beach and dune systems shall be limited by: strict maintenance of
existing setback requirements, adherence to storm water detention
requirements, retaining all publicly owned natural habitats in their
undeveloped state and transfer of development rights.
Policy E.2.3 Objective - Clearwater Harbor and Tampa Bay are designated
Outstanding Florida Waters and are under a non-degradation rule. Clearwater
will continue to manage stormwater runoff and control erosion during
construction to reduce waterborne sediments. As additional initiatives are
approved under the SWIM program, they will be considered for inclusion in
the Community Development Code.
Policy E.2.3.1 Restoration and enhancement of disturbed or degraded
drainage systems shall be implemented by upstream detention of stormwater,
maintenance of existing drainage channels, widening of bridges, culverts and
other stormwater conveyance structures.
Policy E.2.4 Objective - Clearwater shall seek funding and approval to
renourish eroded beaches on Sand Key and Clearwater Beach when
necessary. Restored beach areas shall be considered public resources
seaward of construction setback lines and shall not be counted as plan
density or buildable lot area.
Policy E.2.4.1 The City shall seek State funding and approval to enable beach
renourishment when necessary.
Policy E. 3. 1 Objective - Clearwater shall administer land development
regulations to protect public and private property and human life from the
effects of hurricane winds and flooding.
~ Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Policy E.3.1.1 The City shall grant building permits in compliance with the
rules of FEMA.
Policy E.3.1.2 Post-disaster redevelopment plans of coastal areas shall be
designed to reduce the vulnerability of public and private property and include
proper elevations.
Policy E.3.2.2 The City shall develop operating policies that address post-
disaster redevelopment needs to facilitate permissible reconstruction in a
timely manner, which includes participating in the Pinellas County local
Mitigation Strategy
Policy E.3.3.9 The City shall not amend the Future land Use Plan map or
Zoning Atlas to permit any mobile home parks to be located within the coastal
storm area.
Policy E.4.1.2 To the maximum extent feasible, sanitary sewer facilities and
lift stations shall be built to resist the infiltration by floodwaters. The hazard
mitigation annex, which covers the wastewater treatment system, shall be
followed in the event of a storm; and hazard mitigation plans shall be updated
as necessary.
Policy E.4.1.3 Immediate repair and clean-up actions after a storm shall be
limited to removal of debris, and repair of existing primary structures to allow
re-occupancy (repairs to allow re-occupancy shall be considered when
damage is limited to less than fifty percent (50%) of the value of the structure
prior to damage). long-term repair and redevelopment shall consist of
upgrading structures and accessory facilities to expand habitable space or
repair of greater than fifty percent (50%) of the value of the structure prior to
damage. Post-disaster redevelopment and long-term repair can only be
permitted consistent with the requirements of FEMA and the Florida Statutes.
Policy E.4.1.4 Damaged infrastructure shall be repaired or rebuilt to minimize
the potential for future damage. Unless the facility is necessary to serve the
population of the coastal storm area, consideration shall be given to
relocating public facilities outside the coastal storm area.
Policy E. 4.1.6 Repair and rebuilding of critical facilities such as water
facilities, sewage treatment plants and lift stations, and other utilities
damaged in future storms shall be reconstructed to minimize hurricane
vulnerability.
; Clearwater
u~
37
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMP\2009 ylan _9_1_2009 jinal.docx
38
S :\ESM\S taftlAMcKinney\2009 _FLOODPLAIN_MAN AGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
D. Conservation Element
F.1.2 Objective - The City shall continue to protect floodplains, drainage
ways, and all other natural areas having functional hydrological
characteristics.
Policy F.1.2. 1 Any construction in the one hundred (100) year floodplain shall
comply with all requirements and standards of the Federal Emergency
Management Agency of the Federal Flood Insurance Administration, and the
City's building codes.
Policy F.1.2.2 Construction and development activities in natural drainage
channels shall be prohibited, except for public flood protection projects
designed to correct specifically identified pre-existing flood conditions and for
which no reasonable alternative flood control measures are available; such
activities shall not increase the flood potential for areas outside the project
target area, nor shall the overall water quality of the affected drainage
channels be reduced as a result of the activities.
Policy F.1.2.3 The City shall support the establishment of Total Maximum
Daily Loads (TMDL) for impaired water and its implementation as appropriate
within the City.
Policy F.1.2.4 Utilize design methods that will trap stormwater sediments
before entering surface waters.
Policy F.1.2.5 Cooperate and coordinate activities with the Southwest Florida
Water Management District (SWFWMD) and the Florida Department of
Environmental Protection (FDEP) in the implementation of the Surface Water
Improvement and Management (SWIM) Program including maintaining and
upgrading the quality of water of Tampa Bay and Clearwater Harbor.
Policy F.1.2.6 Natural filtration techniques and methods such as grassy
swales and natural wetland water storage should be implemented when
appropriate to provide purification of stormwater runoff before entering any
surface waters.
Policy F.1.2.7 Transfer of development rights should be implemented to
provide alternatives to development and degradation of wetlands and other
natural resources.
Policy F.1.2.8 Protect all natural drainage channels from destruction or any
restriction of their functional use and regulate protection through the
Clearwater Community Development Code: this policy may be waived for any
public flood conditions when it can be demonstrated that: (a) No
; Glearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwa ter
Floodplain Management Plan
reasonable alternative flood control measures are available; (b) The project
will not increase the flood potential for areas outside the project target area;
and (c) Overall water quality of the affected drainage channel will not be
reduced as a result of the project
Policy F.1.2.9 Design and approve future redevelopment of Clearwater's
downtown waterfront with consideration of the natural bluff features through
the Future land Use Plan, the Community Development Code, Clearwater
Downtown Redevelopment Plan, and in accordance with the City Charter.
Policy F.1.2.10 Monitor and enforce City requirements for treatment ponds
and environmental mitigation sites.
Policy F.1.8.9 Pesticide dealers, auto paint and repair shops, salvage yards,
and other small quantity generators of hazardous waste identified as per
Florida State law shall provide storage of hazardous products and by
products outside of the elevation of the 25-year flood plain, shall not cause
the direct discharge of runoff from said storage areas into water of the State,
and shall have containment/separation traps of adequate size to prevent any
discharge in case of a spill or accident.
F.2 GOAL - DISCHARGES OF STORMWATER SHAll BE MANAGED TO
PROVIDE FLOOD PROTECTION FOR THE CITIZENS OF THE CITY OF
CLEARWATER AND TO PRESERVE, PROTECT, AND ENHANCE THE
WATER QUALITY OF RECEIVING WATERBODIES.
F.2.1 Objective - The City shall continue to protect, improve and enhance
surface waters from stormwater runoff discharging into both interior and
coastal surface waters.
Policy F.2.1.1 The City shall incorporate water quality protection and
enhancement criteria into all City stormwater management plans.
Policy F.2.1.2 The use of natural alternatives, the conservation of natural
drainage systems, and the protection and improvement of the quality of
receiving waters shall be a goal of the City stormwater management plans.
Policy F.2.1.3 A stormwater utility fee or other adequate funding mechanism
shall be continued to provide the necessary funding mechanism to achieve
this goal.
Policy F.2.1.4 The City shall continue to implement a stormwater ordinance
requiring redeveloped sites other than single-family residential areas, to
incorporate water quantity and quality controls consistent with new
development regulations, recognizing that case-by-case limitations
~ tlearwater
u~
39
S :\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 Jinal.docx
40
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan_9 _1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
may call for partial controls, offsite improvements or payments in lieu of
improvements to achieve this goal.
Policy F.2.1.5 Management plans shall be developed for waterbodies with
known or suspected water quality problems in the City to include Tampa Bay,
Clearwater Harbor, Stevenson Creek, Allen's Creek, and Alligator Creek.
Policy F.2.1.6 The City shall systematically and timely prepare and update
watershed or waterbody specific management plans in accordance with the
Surface Water Improvement and Management (SWIM) program. These plans
shall include both water quality and flood control considerations and
recommended funding sources.
Policy F.2.1.7 The City shall prioritize and implement all City approved
stormwater management plans.
Policy F.2.1.8 All City stormwater management plan projects within
watersheds of the City shall comply with applicable SWIM Plans for that
waterbody or watershed.
Policy F.2.1.9 The City shall coordinate with and supplement the County's
surface water monitoring program.
Policy F.2.1.10 The City will encourage the use of "Low Impact Development"
techniques for stormwater management, such as minimal land disturbance,
the preservation of native vegetation, and the minimization of impervious
cover, through site plan and internal review processes.
E. Recreation and Open Space Element
Policy G 1.4.4 Preserve coastal and interior wetlands, f1oodways, floodplains
and other environmentally significant areas to protect their aesthetic and
environmental qualities which benefit the City.
Policy G 1.4.8 Coordinate recreation planning with other plans concerning
water quality, stormwater management, fish and wildlife management, and
environmental education.
F. Intergovernmental Coordination Element
2.6 Objective Clearwater shall participate on a technical and a policy level in
the preparation, planning, funding, coordination, and implementation of a
master stormwater management plan with other governmental
~ Cllarwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
entities, SWFWMD, State Department of Environmental Protection (DEP) and
other affected parties.
Policy H 2.6.1 The Public Works Department shall continue to coordinate and
oversee preparation of stormwater management plans.
Policy H 2.6.2 Clearwater shall participate in inter local agreements to
implement and fund stormwater management plan improvements.
Policy H 2.6.3 The Engineering Department shall prepare, monitor, and
update watershed plans and coordinate with other jurisdictions.
2.7 Objective Clearwater shall coordinate with Pine lias County's Department
of Environmental Management and with the Department of Environmental
Protection to upgrade and maintain air quality.
Policy H 2.7.2 Clearwater shall continue and seek to expand, as necessary,
joint use agreements for recreational facilities with the Pinellas County School
Board and other recreation facility providers.
G. Capital Improvements Element
I 1.2 Objective Management of Clearwater's coastal zone shall limit public
expenditures to those necessary to serve existing and planned development.
Policy 1.2.1 City infrastructure located in coastal high hazard areas shall be
given first priority in receiving renourishment projects, necessary
maintenance, and repair and replacement projects; the coastal high hazard
area is determined to be evacuation levellA" zone for a Category 1 hurricane
as delineated by Pinellas County and the Tampa Bay Regional Planning
Council.
Policy 1.2.2 Damaged infrastructure shall be replaced or rebuilt to minimize
the potential for future damage. Unless the facility is necessary to serve the
population of the coastal zone, consideration shall be given to relocating
public facilities outside the coastal zone.
Policy 1.2.3 Infrastructure damage in coastal high hazard areas during
previous storms was limited to beach and water-dependent uses. Repairs and
rebuilding of sewage treatment plants and lift stations damaged in future
storms shall be conducted with such methods to minimize hurricane
vulnerability.
Policy 1.2.4 The following infrastructure improvements shall be specifically
considered as part of the local coastal zone management element for
~ Clearwater
;;~
41
S :\ESM\StaftlAMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9 _ I _2009 Jinal.docx
42
S\ESM\Staff\AMcKinney\2009 ]LOO DPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
purposes of consistency with applicable State law: expansion/rebuilding of
Memorial Causeway Bridge and addition of turn lanes; expansion of public
park and beach access facilities; beach renourishment, and addition of
sanitary sewer and street drainage capacities, as needed, to implement water
quality objectives. These improvements are consistent with the local coastal
zone management element and are eligible for State funds, which are now or
may become available.
Policy 1.2.5 Level of service standards will not be the exclusive determinant of
the need for a capital improvement in the coastal high hazard area when a
repair, remodeling, renovation or replacement of an obsolete or worn out
facility, as determined by the City Manager and City Commission, is
necessary or when capital improvements are provided in excess of the
standards adopted in this Plan based upon the following criteria:
1. The capital improvement does not make financially infeasible any capital
improvement of the same type that is needed to achieve or maintain the
standards for levels of service adopted in this Plan; and
2. The capital improvement does not contradict, limit or substantially change
the goals, objectives and policies of any element of this Plan; and
3. The excess capacity is an integral part of a capital improvement that is
needed to achieve or maintain standards for levels of service; or
4. The excess capacity provides economies of scale making it less
expensive than a comparable amount of capacity if acquired at a later
date; or
5. The asset acquired is land that is environmentally sensitive or designated
by the City as necessary for conservation, recreation or protection of
coastal high hazard areas; or
6. The excess capacity is part of a capital project financed by general
obligation bonds approved by referendum.
Preventive Activities
Preventive activities keep flood problems from getting worse by regulating land
use and development through planning, land acquisition and/or regulation.
Project A. 1 The City will continue to participate in the Pinellas County Local
Mitigation Strategy.
~ Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Project A.2 The City will assist the Tampa Bay Regional Planning Council and
Pinellas County with Project Impact implementation such as providing
property information data, and other general support activities. Project Impact
is the FEMA mitigation initiative to reduce local vulnerability to natural
disasters.
Project A.3 As part of the 2007 EAR-based amendments, the Planning
Department will research amending the Comprehensive Plan to prohibit new
construction of hospitals, nursing homes and convalescent homes in the
Coastal High Hazard Area. - Completed
Project A.4 As part of the 2007 EAR-based amendments, the Planning
Department will research amending the Comprehensive Plan to prohibit the
siting of new mobile home parks within the Coastal High Hazard Area. -
Completed
Project A.5 The City will pursue the acquisition of land that has a history of
flooding and is an important component to alleviate localized flooding and
flooding in other areas of the City.
Project A.6 The City will continue to support implementation of the Tampa
Bay Estuary Program's Comprehensive Conservation and Management Plan
for Tampa Bay through its projects and activities.
Project A. 7 As part of the CRS program requirements, the Floodplain
Management Planning Committee will conduct a yearly evaluation of the
goals and activities of the Floodplain Management Plan.
Property Protection
Property Protection activities are usually undertaken by property owners on a
building by- building or parcel basis and are intended to alleviate the damage
inflicted by episodes of flooding.
Project B.I The City will continue to participate in the FEMA Project Impact
program to help reduce the impacts of natural disasters.
Project B.2 The City will continue to provide "Substantial Improvement"
information to property owners in the floodplain (Appendix J). This information
will be updated to reflect changes in regulations as necessary.
Project B.3 The Development Services Department will continue to offer the
public information regarding residential flood protection construction methods.
~ Glearwater
u~
43
S:\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 _plan _9_1_2009 Jinal.docx
44
S\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Project 8.4 The Engineering Department will assist homeowners in obtaining
flood mitigation grants through the Florida Department of Community Affairs.
These grants are available on an annual basis and are given priority to
repetitive loss properties.
Project 8.5 The City will continue to utilize the flood complaint handling
process to better address flood issues (Appendix H).
Project 8.6 The City shall assist residents in preparing FEMA Flood Mitigation
Assistance (FMA) Grants that offer funding for the elevation and
demolition/rebuild of properties that have been damaged by flooding in the
past.
Natural Resource Protection
Natural resource protection activities preserve or restore natural areas or the
natural functions of floodplain and watershed areas.
Project C.1 The Parks and Recreation Department will continue to maintain,
protect and manage natural areas that are under the city jurisdiction as open
space and preservation parks.
Project C.2 The City will designate a representative to field concerns
regarding dune reconfiguration or construction. This representative will
coordinate directly with the region's State DEP agent to facilitate the reporting
of any prohibited actions.
Project C.3 The City will continue to pursue the creation and enhancement of
wetlands that provide compensation for future unavoidable City-incurred
wetland impacts from roadway improvements, drainage improvements and
public utility expansions.
Project C.4 The City will continue to provide support to the U.S. Army Corps
of Engineers (USACOE) for the design and implementation of Stevenson
Creek Estuary Restoration Project.
Project C.5 The Stevenson Creek Watershed Management Plan will continue
to be updated as recommended projects are implemented.
Emergency Services
Emergency Services are post-disaster mitigation measures taken during and
after flooding that helps minimize the negative impact on resident's well-being
and property.
; tlearwater
o~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Project 0.1 The Emergency Management office will work in conjunction with
other City departments and Pine lias County Emergency Management to
update the City's Emergency Operation Plan as needed.
Public Information
Public Information activities advise property owners and residents about the
hazards of the floodplain through several means of advertisement and
information dissemination.
Project E.1 The City will utilize C-VIEW TV, the City of Clearwater television
station, to provide flood mitigation information and hurricane preparedness
information to the public.
Project E.2 The City will continue to provide flood mitigation information to
residents through various City publications and advertisements. These
information mailings will be targeted to repetitive loss properties.
Project E.3 The City will continue to work with neighborhoods experiencing
flooding to provide flood mitigation and procedures information.
Project E.4 The Clearwater Library system, Engineering Department and
Development Services Department will continue to make floodplain
information available to the public.
Project E.5 The City will provide information as necessary to the various
hurricane guides regarding flood safety information.
Project E. 6 The City will provide information as necessary to Verizon that
provides natural hazard information including flood procedures in the
telephone book.
Project E. 7 The City will provide additional flood information on the City's
Website at myclearwater.com.
Project E. 8 The City will submit an application for certification as a National
Weather Service StormReady City. - Pinellas County is StormReady
Stormwater Management Projects
Stormwater Management Projects are capital improvement projects constructed
to reduce flooding potential, enhance drainage and improve
~.Cliarwater
u~
45
S :IESMIStaff\AMcKinneyI2009 JLOODPLAIN _MAN AGEMENT ]LAN12009
FMP12009 --plan _9_ I _2009 _final.docx
The construction contract was awarded to Caladesi
Company on April 15, 2009, in the amount of $ 1,662,525.
began in May 2009 with completion in 2010.
Construction
Construction
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
stormwater quality. The CISMC, comprised of City staff develops and maintains
a master list of improvements.
This list is available in the Implementation of Mitigation Measures section of this
document. The following is a list of CISMC projects that will be overseen, or
continue to be overseen by the Engineering Department.
Project G.1 lake Bellevue Stormwater Management Project
The Lake Bellevue Stormwater Management Project consists of the
expansion of Lake Bellevue to provide additional flood storage capacity and
littoral zone for water quality improvements, within the Stevenson's Creek
Watershed. The expansion requires the excavation of an area of
approximately 8 acres of unutilized areas of Ed Wright Park and Ross Norton
Park. This project includes modification of the lake outfall structure to control
the 100-year flood discharge, elevating the eastern 400 feet of Dempsey
Street, and construction of a low berm through a portion of the park.
Completion of this project is expected to remove 17 dwelling units from the
1 OO-year flood zone.
This design cost for this project was $266,717 and construction costs are
estimated at 1.6 M. The Southwest Florida Water Management is funding
$348,871 of the construction costs and FDEP is funding $366,624 of the
construction costs.
Project G.2 Spring Branch Stormwater Improvements
The improvements will consist of widening approximately 700 feet of the
Spring Branch Channel of Stevenson's Creek downstream of King's Highway
and constructing of a stormwater retention treatment pond. The total area of
the pond will be approximately 2.5 acres and will require acquisition of a 4-
acre parcel from the Sunset Point Baptist Church. This project will reduce the
100 year flood plain, stabilize the conveyance features, provide treatment and
attenuate the runoff in this area of the watershed.
The design and construction estimate of this project is $2,500,00. Design of
this project is ongoing with construction anticipated to commence in October
2009 with completion in 2010. The Southwest Florida Water Management
~'learwater
u~
46
S:\ESM\StafflAMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --plan _9_1 _2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
District and FDEP are cooperatively funding the land acquisition, design and
construction of this project.
Project G.3 Stevenson Creek Estuary Restoration Project
This project will involve the dredging of approximately 196,000 cubic yards of
sediments from the Stevenson's Creek estuary, removal of exotic vegetation
and replanting of native vegetation. The project components will restore
habitat, reduce odors associated with the organic muck, improve area
aesthetics, restore dissolved oxygen levels, increase the channel cross
sections, reduce potential flooding and help reestablish the estuary tidal flow
and food chain base.
The total project cost is estimated at $7,360,987. The USACOE is the lead
agency on this project. The Corp will manage this project and fund 65
percent of the project costs. The City will be responsible for the remaining 35
percent of the project cost.
The contract was awarded in 2009. Construction is scheduled to begin in
2009 and is expected to be complete in 2010.
Project G.4 Tropic Hills Phase I, II, III
Tropic Hills is located within in the Coastal Basin 2 watershed. Tropic Hills
Drainage Improvements Project consists of 3 phases:
Phase I consists of the rehabilitation of an existing outfall channel serving
250-acre drainage basin. The proposed rehabilitation activities including
construction of a gabion wall system for stabilization of the north bank,
installation of the gabion mattress on the bottom of the channel to minimize
scour, and replacement of the existing failing seawall along the south side of
the channel. The design and construction estimate of phase I is $2,500,000.
The project is cooperatively funded by the SWFWMD, SWIM Section and the
City of Clearwater. The City anticipates the construction to start in 2009 with
completion in 2010.
Phase II consists of replacing the 2 undersized 36" pipes under U.S. 19 with a
4'x10' box culvert during the reconstruction from SR 60 to Ham Blvd. The
estimate costs for this phase is $1,114,000 and construction starts in August
2009 and complete by 2012.
Phase III consists of replacing 900' undersized pipe that is upstream of phase
II. The design and construction estimate of this phase is $2,500,000.
~ Clearwater
u~
47
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 --plan _9_1_2009 _final.docx
~ Clearwater
u~
48
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMP\2009 --plan _9_] _2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The City anticipates the construction to start by 2012 and complete by 2013.
When all three phases of the project are complete, the Tropic Hills
neighborhood will have an outfall that reduces the risk of houses and streets
flooding.
Project G.5 Alligator Creek Channel F Improvements
The project includes construction to improve drainage of Alligator Creek
Channel F from Old Coachman Road to approximately 1500 feet upstream.
The work involves realigning approximately 850 feet of channel to the
historical flow path within the City's public utility easement, reinforcing and
stabilizing the channel through the installation of approximately 1800 feet of
gabion structures, replacing existing culverts under Old Coachman Road and
Wetherington Road and reconstructing and paving the disturbed areas of Old
Coachman Road and Wetherington Road.
The Contract was awarded to Keystone Excavators, Inc. in the amount of
$1,432,233. Construction will begin in September 2009 and will be complete
in 2010.
Project G.6 Kipling Plaza Lift Station
This project consists of the rehabilitation of the stormwater pump station at
Kipling Plaza on north Clearwater Beach in the Coastal Basin Beach
watershed. This project will be completed in 2010 at an estimated cost of
$100,000.
Project G.7 Myrtle Avel Seminole Street Northeast Outfall System
This project consists of replacing 900 linear feet of aging corrugated storm
pipe, within the Stevenson's Creek watershed. The present pipe
runs diagonally through the area from Seminole and Vine to Palmetto and
MLK. The proposed project will relocate the pipe out of backyards where
there is no easement and into the adjacent city right of ways.
The estimate for this project is approximately $1,500,000. Construction is
anticipated to begin in 2011.
Project G.B Beachwalk Water Quality Spencer Pond
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The City purchased two adjacent properties on Spencer Avenue that are
approximately 1/3 of an acre total. Two additional property adjacent to
Spencer Avenue was purchased that consists of approximately % of an acre.
A proposed pond will be constructed on the combined properties that will
supply most of the water quality treatment benefits required for the Beachwalk
project.
The neighborhood will directly benefit from a stormwater retention pond at the
lowest point of the basin. It will also remove two properties from FEMA's
repetitive loss list and reduce the risk of flooding to adjacent flood prone
properties. The removal of properties from the repetitive loss list will help the
City to reduce flood insurance costs through FEMA's Community Rating
System (CRS).
The estimated cost of the project is $160,000. Construction of the pond is
expected to start in 2010 and be complete in 2011.
Project G.9 Allen Creek
The project consists of channel improvements to Allen's Creek between
Magnolia Avenue and Sandra Drive. It includes two concrete check dams,
approximately 2,000 feet of bank stabilization by installing gabions on each
side of the creek and grading the creek banks above the gabions at a gradual
slope to blend with surrounding topography.
Pine lias County approached the City to partner with them and Southwest
Florida Water Management District (SWFWMD) for the design and
construction of this project. The County was the lead on the project and will
handle design and construction management. The engineers estimate for
this project was $1,651,500.00.
The County received bids on March 5, 2009. The County awarded the
construction contract to Kamminga & Roodvoets, Inc. in the amount of
$895,690.00 in June 2009. Construction will start in September 2009 and be
complete within 270 days.
Project G.10 Alligator Creek Watershed Plan Update
This is a project to perform the 1) Topographic Information, 2) Watershed
Evaluation, and 3) Watershed Management Plan elements of the District's
Watershed Management Program (WMP) for the Alligator Creek Watershed
(ACWMP). The watershed covers an area of approximately 9 square miles
and is located in Clearwater, and Pinellas County. The District and the City
~ Clearwater
u~
49
S :IESMIStafflAMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMPI2009 --p1an_9 _1_2009 Jinal.docx
50
S\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 Jllan _9_1_2009_ final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
cooperatively funded the 1997 ACWMP and many of the recommended
projects.
The revisions to the ACWMP will include developing projects to reduce
flooding, increase water quality and improving natural systems. The revised
model will be in a District approved format that can be imported into newer
versions as software progresses. In addition the information from
implemented projects will be included, existing data will be verified, the
modeling data will be formatted to District Standards and the FEMA maps will
be revised to reflect the existing conditions flooding risk. The City of
Clearwater is requesting that the Pinellas-Anclote River Basin Board provide
$300,000 from its fiscal year FY2009 budget for the revision to the ACWMP.
Project G.11 Stevenson Creek Watershed Plan Update
This is a project to perform the 1) Topographic Information, 2) Watershed
Evaluation, and 3) Watershed Management Plan elements of the District's
Watershed Management Program (WMP) for the Stevenson Creek
Watershed. The watershed covers an area of approximately 6,286 acres and
is located in Pinellas County. Of the 6,286 acres, 4,057 acres (65 percent)
are within the limits of the City of Clearwater. The remaining 35 percent of
the watershed are within the City of Dunedin (1,287 acres or 20%),
unincorporated Pinellas County (859 acres or 14%) and the City of Largo (83
acres or about 1 %).
The District and the City cooperatively funded the Stevenson Creek
Watershed Management Plan (SCWMP) Federal Emergency Management
Agency (FEMA) Map Revision Data Report in October 2001 and many of the
recommended projects.
The revisions to the SCWMP will include developing projects to reduce
flooding, increase water quality and improving natural systems. The revised
model will be in a District approved format that can be imported into newer
versions as software progresses. In addition, the information from
implemented projects will be included, existing data will be verified, the
modeling data will be formatted to District Standards, and the FEMA maps will
be revised to reflect the existing conditions flooding risk. The City of
Clearwater is requesting that the Pinellas-Anclote River Basin Board provide
$375,000 from its fiscal year FY2009 budget for the revision to the SCWMP
Implementation of Mitigation Activities
; Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The City of Clearwater Engineering and Public Service Departments are the
main entities in charge of implementing and managing the projects and
activities that mitigate the effects of flooding. The work force is comprised of
40 staff members that are separated into two divisions. The Engineering
Stormwater Management Division consists of eight employees and is
responsible for project planning, project prioritization, project design,
regulatory compliance and private development plan review. The Public
Services Department consists of 32 employees and is responsible for street
sweeping, pond and ditch maintenance, storm collection maintenance and
repair and infrastructure inspection. The Engineering Stormwater
Management Division has an annual operating budget of approximately $1.3
million and manages approximately $8 million per year in capital improvement
projects.
The City created the Capital Improvement Stormwater Management
Committee (CISMC). The CISMC, comprised of City representatives from the
Engineering and Public Service Departments, regularly convenes to discuss
various issues related to stormwater policy and to address any deficiencies in
the City's Stormwater Management system.
Appendix K contains the list of projects identified by the CISMC. The list
provides the priority of the project established by the committee, with 1.0
being the highest priority; the Engineering Department staff member selected
as project manager; the project classification type; project location; location's
problem; total cost of project; and the project status. In addition to existing
projects, this list also provides the projects that have been completed since
the last floodplain document was approved. As all of the stormwater
management projects listed are approved capital improvement projects,
funding has already been identified by City Council.
The following table provides an implementation schedule for the activities
identified through this Plan. The table includes the project name and
reference number provided in the "Identification and Analysis of Mitigation
Measures" section; the department responsible for implementing the activity;
a timetable for completion; and the current priority of the activity. All of these
projects will be funded through the operating budget of the identified
department. Capital improvements to the City's Stormwater management
systems identified are included in the above table and will not be repeated.
Activit
De artment
Timetable Priori
Annuall
~ CIUbrwater
0~
51
S\ES M\Staft\AMcKinney\2009 ]LOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 -plan _9_ I _2009_ final.docx
I
City of Clearwater
Floodplain Management Plan
I
2. Assist with FEMA's Project Impact Program Planning and
Ene:ineering Ongoing Hie:h
3. Pursue the acquisition of flood prone land Ene:ineering Ongoing Low
4. Support implementation ofTBEP's CCMP Engineering Ongoing Hie:h
5. Re-evaluate the goals and activities of the Floodplain
Manae:ement Plan City wide Annually Hie:h
ProDerty Protection
1. Assist with Project Impact homeowner's mitigation
grant program Engineering Ongoing Hie:h
2. Provide substantial improvement information Development
Services Ongoing Medium
3. Provide flood proofing information Development
Services Ongoing Medium
4. Maintain flood complaint handline: orocess Engineering Ongoing Low
Natural Resource Protection
1. Maintain, protect and manage the City's natural areas Park and Recreation Ongoing Medium
Activity Denartment Timetable Priority
2. Continue support ofthe USACOE's Stevenson Creek
Estuary Restoration Project Engineering Ongoing Low
3. Updates to the Stevenson Creek Watershed
Management Plan Engineering Ongoing Medium
Emerl!:ency Services
1. Update the Emergency Operations Plan City wide Ongoing High
Public Information
1. Utilize C- View to provide information Public Relations Ongoing Medium
2. Flood information in City publication and
advertisements Public Relations Annually Medium
3. Continued coordination with flood prone
neighborhoods City wide Annually Hie:h
4. Distribute updated information to Library Engineering and
Building As Needed Hie:h
5. Provide information to disaster guides Public Relations and
Engineering As Needed Medium
6. Coordinate information with Verizon Public Relations As Needed Low
7. Provide additional flood information on website IT, Engineering and
Public Relations Ongoing Hie:h
I
I
I
I
I
I
I
I
I
I
I
I
High priority activities identified though the implementation schedule that are not
currently in affect, will be implemented using the operating budget of the
identified City department. Any goals and activities not immediately implemented
will be re-evaluated during the annual evaluation of the Plan.
I
I
SECTION 5.0 PLAN MAINTENANCE
I
; .Cllarwater
u~
52
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 -p1an_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Monitoring, Evaluating and Updating the Plan
In 2009, the City created a Floodplain Management Planning Committee (FMPC)
to review and update the floodplain management activities identified in the Plan.
The FMPC was formed to complete this 2009 update and will continue to be
responsible for the review and implementation of the Plan. The FMPC consists
of the CRS coordinator, representatives from Engineering, Planning, and Public
Service Departments.
The FMPC will be responsible for organizing the annual meeting. The meeting
will be held in June of each year and committee members will be responsible for
monitoring and evaluating the progress of the mitigation strategies in the Plan.
The City will review each goal and objective to determine their relevance to
changing situations in the City, as well as changes in County, State or Federal
policy to ensure that the Plan addresses current and expected conditions. The
committee will also review the risk assessment portion of the Plan to determine if
this information should be updated or modified. The parties responsible for the
various implementation actions will report on the status of their projects and will
include reports on which processes worked well, any difficulties encountered,
how coordination efforts were proceeding and which strategies should be
revised.
The FMPC will then have three months to update and modify the Plan before
submitting it to the CRS Coordinator. If no changes are necessary, the CRS
Coordinator will be given a justification for this determination. Updates will be
provided with the annual CRS re-certification.
Implementation through Existing Programs
The City of Clearwater currently utilizes comprehensive land use planning,
capital improvements planning and building codes to guide and regulate
development in the City. After the adoption of the Floodplain Management Plan,
the City will use this document to continue to address flood hazards in its
Comprehensive Plan and land use regulations. The City's Planning and
Development Department will conduct periodic reviews of the Comprehensive
Plan and land use policies, analyze any plan amendments and implement these
requirements. The capital improvement planning that occurs in the future will
also contribute to the goals of the Floodplain Management Plan.
The City's Planning and Development Department is responsible for
administering the building code throughout the City. After the adoption of the
Floodplain Management Plan Update, the Planning and Development
Department will work with the State Building Code Office to ensure
~ Clearwater
u~
53
S\ESM\StaftlAMcKinney\2009 _FLOO DPLAIN _MANAGEMENT _PLAN\2009
FMP\2009 J'lan_9 _1_2009 _final.docx
54
S :\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9 _ I _2009_ final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
that the City enforces the new building code. This is to ensure that all new
construction in the City meets the identified requirements to limit the effects of
flooding.
The Engineering Department is responsible for project planning, project
prioritization, project design, regulatory compliance and private development plan
review. The FMPC and the CISMC are comprised of City representatives from
the Engineering and Public Service Departments. These committees will
continue to discuss issues related to stormwater policy and address any
deficiencies in the City's Stormwater Management system.
Copies of the City's Floodplain Management Plan will be catalogued and kept on
hand at all branches of the City's public library. The existence and location of
these copies will be publicized. In addition, copies of the Plan and any proposed
changes will be posted on the City's Government website. This site will also
contain contact information and direction on where to submit comments or
concerns. The annual review meeting of the FMPC will be publicized in the
newspaper and will be open to the public. The meeting will provide the public a
forum for which they can express concerns, opinions or ideas about the Plan.
The Engineering Department will publicize, host and mediate this meeting.
; Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
References
"Alligator Creek Watershed Management Plan", City of Clearwater, July 1999, &
Update 2005
"Clearwater Comprehensive Plan", City of Clearwater, July 2001.
"CRS Coordinator's Manua/", Federal Emergency Management Agency, National
Flood Insurance Program, Community Rating System, February 2002.
"Erosion and Siltation Control Policy", City of Clearwater, April 2003.
"Example Plans", Federal Emergency Management Agency, National Flood
Insurance Program, Community Rating System, March 2003.
"Flood Insurance Rate Maps, City of Clearwater, Community Number 125096",
Federal Emergency Management Agency, National Flood Insurance Program,
October 2003.
"Flood Insurance Study, City of Clearwater", Federal Emergency Management
Agency, Aug ust 1991.
"Floodplain Management Plan", City of Clearwater, September 2001.
"Pinellas County Local Mitigation Strategy", Tampa Bay Regional Planning
Council, December 2003.
"The Local Mitigation Strategy: A Guidebook for Cities and Counties", Florida
Department of Community Affairs, January 1999.
"NO ADVERSE IMPACT: A Toolkit For Common Sense Floodplain
Management", Association of State Floodplain Managers, September 2003.
"Repetitive Loss Detail by Community Report", Federal Emergency Management
Agency, National Flood Insurance Program, Community Rating System, July 31,
2003.
"STATE AND LOCAL MITIGATION PLANNING how-to-guide: Getting Started",
Federal Emergency Management Agency, September 2002.
"STATE AND LOCAL MITIGATION PLANNING how-to-guide: Developing the
Mitigation Plan", Federal Emergency Management Agency, April 2003.
"STATE AND LOCAL MITIGATION PLANNING how-to-guide: Understanding
Your Risks", Federal Emergency Management Agency, August 2001.
rwater
u~
55
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --plan _9_ I _2009 jinal.docx
>
u~
rwater
56
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 -p1an_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
"State and Local Plan Criteria Under the Disaster Mitigation Act of 2000", Federal
Emergency Management Agency, July, 2002.
"Stevenson Creek Watershed Management Plan", City of Clearwater, October
2001.
"Stormwater Management Design Criteria", City of Clearwater, July 2001.
;;
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
On-line Resources
Association of State Floodplain Managers,
http://www . floods. orQ/home/d efau It. asp
Pinellas County Property Appraiser's Office,
http://www.pcpao.org/
Climatic Diagnostics Center, http://www.cdc.noaa.aov/index.html
Department of Community Affairs, Bureau of Recovery and Mitigation,
http://www.floridadisaster.ora/brm/
Emergency Management Institute, Community Rating System Resource Center,
http://trainina.fema.aov/EMIWeb/CRS/index.htm
Federal Emergency Management Agency, http://www.fema.aov/
Federal Emergency Management Agency, Map Service Center,
http://www.msc.fema.Qov/
Florida Division of Emergency Management, http://www.f1oridadisaster.org/
National Climatic Data Center, http://www.ncdc.noaa.gov/oa/ncdc.html
National Oceanic and Atmospheric Administration,
http://www.noaa.aov/floods.htm I
Pinellas County Emergency Management,
http://www.pinellascountv.ora/emergencv/default.htm
Tampa Bay Regional Planning Council Emergency Management Program,
http://www . tampabavd isaste r. orQ/
US Census Bureau, http://www.census.aov/
US Army Corps of Engineers, http://www.usace.armV.mil/
~~llarwater
u~
57
S :\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan_9 _ 1_2009 _final.docx
58
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MAN AGEMENT _ PLAN\2009
FMP\2009 ylan _9_ I _2009 JinaI.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix A
Resolution 09-37
Adopting the Floodplain Management Plan
~ Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
RESOLUTION NO. 09-37
A RESOLUTION ADOPTING THE FLOODPLAIN
MANAGEMENT PLAN: TRANSMITTING THE PLAN
TO THE FEDERAL EMERGENCY MANAGEMENT
AGENCY AS REQUIRED BY THE NATIONAL FLOOD
INSURANCE PROGRAM'S COMMUNITY RATING
SYSTEM; AUTHORIZING THE CITY MANAGER TO
INITIATE ACTIVITIES AS RECOMMENDED IN THE
FLOODPLAIN MANAGEMENT PLAN; AND
PROVIDING AN EFFECTIVE DATE.
WHEREAS, the National Flood Insurance Program (NFIP) provides federally
supported flood insurance in communities that regulate development in their floodplains,
and the Community Rating System (CRS) reduces flood insurance premiums in those
communities that do more than implement the minimum regulatory requirements; and,
WHEREAS, the City of Clearwater is required to update the Floodplain
Management Plan in order to continue to receive CRS credits for this document; and
WHEREAS, the City Council adopted Floodplain Management Plans in 2000 and
2004, which updated the Repetitive Loss Plan adopted on December 11, 1991; and
WHEREAS, the Floodplain Management Plan updates the 2004 Floodplain
Management Plan in compliance with the 2007 CRS Coordinators Manual; and
WHEREAS, the Floodplain Management Plan as amended is consistent with the
Clearwater's adopted Comprehensive Plan; and
WHEREAS, adopting the Floodplain Management Plan will provide the citizens
of Clearwater access to the Flood Hazard Mitigation Assistance program funds; and
WHEREAS, various City projects, programs, operations and initiatives in the
Plan may lower flood insurance rates for the City residents; now, therefore
BE IT RESOLVED BY THE CITY COUNCIL OF THE
CITY OF CLEARWATER, FLORIDA:
Section 1. The Floodplain Management Plan as amended and attached hereto is
adopted.
~(l'arwater
u~
59
S :IESM\Staff\AMcKinneyI2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMPI2009 -'plan _9 _1_2009 _finaI.docx
PASSED AND ADOPTED this 17th
day of September
,2009.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Section 2. The Floodplain Management Plan shall be transmitted to the Federal
Emergency Management Agency for appropriate action as required under the National
Flood Insurance Program's Community Rating System.
Section 3. The City Manger is authorized to initiate activities as recommended in
the Floodplain Management Plan.
Section 4. This resolution shall take effect immediately upon adoption.
Frank V. Hibbard
Mayor
Approved as to form:
Attest:
Leslie K. Dougall-Sides
City Attorney
Cynthia E. Goudeau
City Clerk
; Clearwater
u~
60
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANA GEMENT ]LAN\2009
FMP\2009 jllan _9_ I _2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
~(learwater
u~
Appendix 8
FMPC Meeting Minutes
61
S:\ESM\StaftlAMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_ I _2009 JinaLdocx
2009 Floodplain Management Plan
Kick Off Meeting Minutes
March 3, 2009 - MSB 221
Attendees:
Allison McKinney
Elliot Shoberg
Ozell George
Catherine Lee
Scott Rice
Heather Shell
James Hersh
Jack Fahey
Muhammad Abdur-Rahim
CRS Coordinator - Engineering / Stormwater
Engineering Stormwater Manager
Public Services Supervisor II
Planner II
Engineering Assistant Director
Public Communication
Engineering / GIS
Plans Examiner - Dev & Neighbor Services
Stormwater Maintenance Manager
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The meeting began with introductions. The purpose of the meeting was to
discuss updating the existing Floodplain Management Plan (FMP).
Allison began the meeting be describing the NFIP CRS program and explained
that residents can obtain flood insurance & obtain a discount because the City
participates. The City had a cycle visit in 2008 and one of the requirements to
complete the verification visit is to provide the update to the FMP. The schedule
to complete the Plan presented. The Plan must be adopted by City Council by
October 1,2009.
The specific sections of the Plan that would be updated were reviewed and
discussed. Each department that would need to provide the updated information
was determined as follows:
· Planning is responsible for the Community Development Code -
Chapter 51 Flood Damage Prevention and Catherine will provide the
most recent version of the document.
. Planning is responsible for Community Development Code, Art. 4, Div.
13, Land Clearing and Grubbing and Catherine will provide the most
recent version of the document.
. Planning is also responsible for the Clearwater Comprehensive Plan.
The Stormwater Sub-element should be included in the FMP policy
section.
. Catherine will provide the current version of the comp plan and indicate
the policy numbers that deal with stormwater and should be included.
The planning department verified that review of the EAR was completed in 2006.
Catherine will provide the current version of the document and will use this
The Planning department will provide the current application for Non-Substantial
Damage/Improvement Review.
~ Clearwater
u~
62
S :\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MANA GEMENT ]LAN\2009
FMP\2009 Jllan _9 _1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
-
City of Clearwater
Floodplain Management Plan
Each of the following sections were discussed in detail.
· Population & Land Use (pg 1, 5, 9) - Planning will provide updated
information
. Housing and Development (pg 9) - GIS will provide updated data
. Development Constraints (pg 10) - No changes will be made
. Population in Flood Insurance Zones & Hurricane Evacuation Levels (pg
14) - GIS will provide updated data
. Special Facilities Populations (pg 15) - GIS will provide updated data
· Annexation Areas (pg 19) - Planning will provide updated data
· Critical Facilities in City & Replacement Cost (pg 20) - GIS will provide
updated data
. Critical Facilities in Floodplain & Replacement Cost (pg 20) -GIS will
provide updated data -Replacement cost was not going to be included in
this update
At the next progress meeting additional sections would be discussed in detail.
Information from capital improvement project lists would be used to evaluate the
implementation of the 2004 plan activities.
GIS will provide all of the following figures:
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
City Service Area and FEMA Flood Zones
SWFWMD Drainage Basins
Drainage Basins inside the City Service Area
City Zoning Map
Future Land Use Map
Elevation Contours
Flood Insurance Zones, FEMA 2005
Water bodies - Creeks, Lakes & Ponds
Hurricane Evacuation Levels
Hurricane Storm Surge Areas
Special Needs Facilities
Repetitive Loss Property Locations
Critical Facilities
Sanitary Sewer Facilities
Natural Gas Infrastructure
Public and Private School Facilities
Please review and provide updated information by 4/10/2009.
Please provide all information and maps to Allison by 4/10/2009.
63 S\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _PLAN\2009
FMP\2009 -plan _9_ I _2009_ final.docx
2009 Floodplain Management Plan
Progress Meeting Minutes
March 30, 2009 - MSB 227
Attendees:
Allison McKinney
Catherine Lee
James Hersh
CRS Coordinator - Engineering I Stormwater
Planner II
Engineering I GIS
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The purpose of this meeting was to discuss and review the technical data in
the plan. Each major section of the report was reviewed and progress to date
was discussed.
Catherine mentioned that she was not sure what source to use to update the
Housing and Development information under Risk Assessment. The US
Census gives much higher figures for housing unites than does past City
documents (EAR ad Sub-Area Trend Analysis reports). It was decided to use
the Pinellas County Property Appraiser information to report and categorize
the number of parcels and the structures in the City and in the floodplain. It
was also decided to provide the estimated improved value for the parcels.
All data regarding the floodplain would come from GIS analysis.
Catherine reported that there are approximately 1,210 acres of
unincorporated county land located within the City's planning area, most of
which are developed.
Special facilities population refers to the percent of residents over 60 years of
age.
The Community Development Code - Chapter 51 Flood Damage Prevention
has not changed.
The Community Development Code - Article 4, Division 13, Land Clearing
and Grubbing has not changed.
Catherine stated that the Clearwater Comprehensive Plan has been updated
and approved. She indicated the policies from the comp plan and the
stormwater element that should be updated in the plan.
Catherine provided updated population, land use, population growth and
current population density. She also provided updates for the development
~ Clearwater
u~
64
S\ESM\S taff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --plan _9_1_2009 JinaLdocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
-
City of Clearwater
Floodplain Management Plan
constraints section.
The CRS coordinator has reviewed the hazard mitigation strategy section and
provided applicable updates.
The new floodplain management planning committee that was created will
perform plan maintenance. This process will be described in the plan.
The CRS coordinator has updated the CIP list and the stormwater
management project descriptions. This information has been added to the
plan.
Jim will continue to work with Allison directly to update the figures and GIS
data.
; Clearwater
u~
65
S :\ESM\Staff\AMcKinney\2009 _ FLOO DPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 Jinal.docx
Clearwater
~
66
S :\ESM\Staff\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_] _2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix C
Flood Protection Questionnaire
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
City of Clearwater Floodplain Management Plan - 2009 Update
Flood Protection Questionnaire
Property address: Years living at this address:_
1. Has your home or property ever been flooded or had a water problem ( ) yes( ) no
If "yes", please complete the entire questionnaire. If "no", please complete questions 6-11.
2.
In what years did the flood occur, and was it due to a named hurricane or tropical storm? If so, please provide the
name of the storm(s).
3.
Where did you get water and how deep did it get? (In feet)
( ) In crawl space: deep ( ) In yard only:
( ) Over first floor: deep
( ) Water kept out of house by sandbagging or other protective measure
deep
4.
What do you feel was the cause of your flooding? Check all that apply to your situation
( ) Storm sewer backup ( ) Sanitary sewer backup
( ) Sump pump failure/power failure ( ) Standing water next to house
( ) Extreme high tide
( ) Overbank flooding from CreeklLake/lntercoastallGulf
( )Other
5.
Have you installed any flood protection measures on your property?
( ) Sump pump ( ) Gutters
( ) Waterproof walls ( ) Regraded yard to keep water away from
building
() Other
6.
Are there any areas in your neighborhood (streets, yards, vacant lots, etc.) that consistently get flooded during
periods of heavy rain?
If yes, please describe the location of the areas by using intersections or street addresses.
7. What type of foundation does your building have?
( ) Slab
( ) Crawlspace
8. Do you have flood insurance with your homeowner's insurance?
( ) Yes ( ) No
9. Have you ever received information on how to protect your family and home from flooding?
( ) Yes ( ) No
10. If yes, how recently?
( ) Within the last year () Between 1 and 2 years () Between 2 and 5 years () 5 years or more
11. From wthom did you last receive information from about safeguarding your family and home from flooding?
( ) News Media ( ) Insurance agent ( ) Other non-profit agency
( ) City of Clearwater ( ) Utility company ( ) Not sure
( ) Other government agency () American Red Cross ( ) Other
Please include any additional comments you may have about flooding in your area.
City of Clearwater - Engineering Department 100 South Myrtle A venue, #220 Clearwater, Florida 33756-5520
~Clearwater
u~
67
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -p1an_9 _1_2009 _finaldocx
68
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix D
Community Development Code, CH 51 - Flood Damage Prevention
0~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwa ter
Floodplain Management Plan
Community Development Code, CH 51 - Flood Damage Prevention
*Cross references: Buildings and building regulations, ch. 47; minimum floor
elevation for buildings constructed after February 3, 1975, 947.011; restoration
of electrical service to flooded structures, 947.012.
Article I. I n General
Sec. 51.01. Findinqs of fact.
Sec. 51.02. Purpose of chapter.
Sec. 51.03. Definitions.
Sec. 51.04. Interpretation of chapter.
Sec. 51.05. Warninq and disclaimer of liability.
Sec. 51.06. Penalties for violation of chapter.
Sec. 51.07. Lands to which this chapter applies.
Sec. 51.08. Adoption of maps and study.
Sec. 51.09. Development permit required.
Sec. 51.10. Administration. permit procedures. duties of buildinq official.
Sec. 51.11. Variances from chapter.
Article II. Flood Hazard Reduction
Sec. 51.31. General standards.
Sec. 51.32. Specific standards.
Sec. 51.33. Streams without established base flood elevations or floodways.
Sec. 51.34. Subdivision proposals.
Sec. 51.35. Areas of shallow f100dinq (AG zones).
ARTICLE I. IN GENERAL
Sec. 51.01. Findings of fact.
The city commission finds and declares that:
(1) The flood hazard areas of the city are subject to periodic inundation which results in
loss of life and property, health and safety hazards, disruption of commerce and
governmental services, extraordinary public expenditures for flood protection and relief,
and impairment of the tax base, all of which adversely affect the public health, safety and
general welfare; and
(2) These flood losses are caused by the cumulative effect of obstructions in floodplains
causing increases in flood heights and velocities, and by the occupancy in flood hazard
areas by uses vulnerable to floods or hazardous to other lands which are inadequately
elevated, floodproofed, or otherwise unprotected from flood damages.
(Code 1980, S 146.002)
Sec. 51.02. Purpose of chapter.
It is the purpose of this chapter to promote the public health, safety and general welfare
and to minimize public and private losses due to flood conditions in specific areas by
provisions designed to:
(1) Restrict or prohibit uses which are dangerous to health, safety and property due to
water or erosion hazards, or which result in damaging increases in erosion or in flood
heights or velocities;
~ .(learwater
u~
69
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 ylan _ 9 _1_2009 Jinaldocx
70
S\ESM\S taff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 Jllan_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
(2) Require that uses vulnerable to floods, including facilities which serve such uses, be
protected against flood damage at the time of initial construction;
(3) Control the alteration of natural floodplains, stream channels and natural protective
barriers which are involved in the accommodation of floodwaters;
(4) Control filling, grading, dredging and other development which may increase
erosion or flood damage; and
(5) Prevent or regulate the construction of flood barriers which may unnaturally divert
floodwaters or which may increase flood hazards to other lands.
(Code 1980, S 146.003)
Sec. 51.03. Definitions.
The following words, terms and phrases, when used in this chapter, shall have the
meanings ascribed to them in this section, except where the context clearly indicates a
different meaning:
Addition (to an existing building) means any walled and roofed expansion to the
perimeter of a building in which the addition is connected by a common load bearing wall
other than a firewall. Any walled and roofed addition which is connected by a firewall or
is separated by independent perimeter load bearing walls is new construction.
Appeal means a request for a review of the building official's interpretation of any
provision of this chapter or a request for a variance.
Area of shallow flooding means a designated AO or VO zone on the flood insurance rate
map (FIRM) with base flood depths from one to three feet where a clearly defined
channel does not exist, where the path of flooding is unpredictable and indeterminate, and
where velocity flow may be evident.
Area of special flood hazard means the land in the floodplain within the city subject to a
one percent or greater chance of flooding in any given year. The area may be designated
on the FHBM as zone A. After detailed ratemaking has been completed in preparation for
publication of the FIRM, zone A is usually refined into zones A, AO, AI-99, VO and Vl-
30.
Base flood means the flood having a one percent chance of being equaled or exceeded in
any gIven year.
Base flood elevation and BFE mean the elevation above mean sea level as shown in the
Flood Insurance Study.
Basement means that portion of a building having its floor subgrade, i.e., below ground
level, on all sides.
Breakaway wall means a wall that is not part of the structural support of the building and
is intended through its design and construction to collapse under specific lateral loading
forces without causing damage to the elevated portion of the building or the supporting
foundation system.
Building means any structure built for support, shelter or enclosure for any occupancy or
storage.
Building official means the building official of the city within the meaning of the
building code adopted for enforcement within the city.
City engineer means the city engineer of the city.
; Cl@arwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Coastal high hazard area means the area subject to high velocity waters, including but
not limited to hurricane wave wash. The area may be designated on a FIRM as zone V 1-
30, VE or V.
Development means any manmade change to improved or unimproved real property,
including but not limited to buildings or other structures, mining, dredging, filling,
grading, paving, excavating, drilling or storage of materials.
Elevated building means a nonbasement building built to have the lowest floor elevated
above the ground level by means of fill, solid foundation, perimeter walls, pilings,
columns, posts, piers, shear walls or breakaway walls.
Elevation means elevation in relation to mean sea level.
Existing manufactured home park or subdivision means a manufactured home park or
subdivision for which the construction of facilities for servicing the lots on which the
manufactured homes are to be affixed, including at a minimum the installation of utilities,
the construction of streets, and either final site grading or the pouring of concrete pads,
was completed before December 31,1974.
Expansion to an existing manufactured home park or subdivision means the preparation
of additional sites by the construction of facilities for servicing the lots on which the
manufactured homes are to be affixed, including the installation of utilities, the
construction of streets, and either final site grading or the pouring of concrete pads.
Flood and flooding mean a general and temporary condition of partial or complete
inundation of normally dry land areas from the overflow of inland or tidal waters or from
the unusual and rapid accumulation or runoff of surface waters from any source.
Flood hazard boundary map and FHBM mean an official map of the city, issued by the
Federal Emergency Management Agency, where the boundaries of the areas of special
flood hazard have been defined as zone A.
Flood insurance rate map and FIRM mean an official map of the city on which the
Federal Emergency Management Agency has delineated both the areas of special flood
hazard and the applicable risk premium zones.
Flood insurance study means the official report provided by the Federal Emergency
Management Agency which contains profiles, the flood boundary floodway map and the
water surface elevation of the base flood.
Floodway means the channel of a river or other water course and the adjacent land areas
that must be reserved in order to discharge the base flood without increasing the water
surface elevation by a designated height of one foot.
Floor means the top surface of an enclosed area in a building (including basement), e.g.,
top of slab in concrete slab construction or top of wood flooring in wood frame
construction. The term does not include the floor of a garage used solely for parking
vehicles.
Functionally dependent facility means a facility which cannot be used for its intended
purpose unless it is located or carried out in close proximity to water, such as but not
limited to a boat docking or port facility, shipbuilding, or ship repair. The term does not
include long term storage, manufacture, sales or service facilities.
Habitable floor means any floor usable for living purposes, including working, eating,
sleeping, cooking or recreation, or a combination thereof, such as but not limited to
bedrooms, living rooms, laundry rooms, bathrooms, workshops, dens and
; Clearwater
u~
71
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_1_2009_ final.docx
72
S :\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 ylan _9_1_2009_ final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
studies. The term does not include a floor used only for storage or vehicle parking
purposes.
Highest adjacent grade means the highest natural elevation of the ground surface, prior
to construction, next to the proposed walls of a structure.
Lowestfloor means the lowest floor of the lowest enclosed area (including a basement).
An unfinished or flood resistant enclosure, usable solely for parking of vehicles, building
access or storage in an area other than a basement area is not considered a building's
lowest floor, provided that such enclosure is not built so as to render the structure in
violation of the applicable nonelevation design requirements.
Mangrove stand means an assemblage of mangrove trees which is mostly low trees
noted for a copious development of interlacing adventitious roots above the ground and
which contain one or more of the following species: black mangrove (Avicennia nitida);
red mangrove (Rhizophora mangle); white mangrove (Languncularia racemosa); and
buttonwood (Conocarpus erecta).
Manufactured home means a structure, transportable in one or more sections, which is
built on a permanent chassis and designed to be used with or without a permanent
foundation when connected to the required utilities. The term "manufactured home" does
not include a recreational vehicle.
Manufactured home park or subdivision means a parcel or contiguous parcels of land
divided into two or more lots for rent or sale as manufactured home sites.
Market value of the structure means the appraised value of the structure, not including
land, driveways, sidewalks, landscaping, swimming pools and other similar
improvements not related to the basic structure, prior to the start of repair or
improvement or, in the case of damage, prior to the damage occurring.
Mean sea level means the average height of the sea for all stages of the tide. It is used as
reference for establishing various elevations within the floodplains. For purposes of this
chapter, the term is synonymous with National Geodetic Vertical Datum (NGVD).
New construction means structures for which the start of construction commenced on or
after December 31, 1974.
New manufactured home park or subdivision means a manufactured home park or
subdivision for which the construction of facilities for servicing the lots on which the
manufactured homes are to be affixed, including at a minimum the installation of utilities,
the site grading or the pouring of concrete pads, is completed on or after December 31,
1974.
Nonconforming structure means a structure in any area of special flood hazard within the
city which is not elevated or floodproofed to National Flood Insurance Program
standards, as set forth in 44 CFR 59 and 60.
North American Vertical Datum and NA VD, as corrected in 2003, mean a vertical
control used as a reference for establishing varying elevations within the floodplain.
Ready for highway use, as applied to a recreational vehicle, means that the recreational
vehicle is on its wheels or jacking system, is attached to the site only by quick disconnect
type of utilities and security devices, and has no permanently attached additions.
Recreational vehicle means a vehicle which is built on a single chassis, 400 square feet
or less when measured at the largest horizontal projection, designed to be self-propelled
or permanently towable by a light duty truck, and designed primarily not for
~ Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
use as a permanent dwelling but as temporary living quarters for recreational, camping,
travel or seasonal use.
Sand dunes means naturally occurring accumulations of sand in ridges or mounds
landward of the high-water line on the beach.
Start of construction, for other than new construction or substantial improvements under
the Coastal Barrier Resources Act (P. L. 97-348), means substantial improvement, and
means the date the building permit was issued, provided the actual start of construction,
repair, reconstruction or improvement was within 180 days of the permit date. The actual
start of construction means the first placement of permanent construction of a structure
on a site, such as the pouring of slabs or footings, installation of piles, construction of
columns, or any work beyond the stage of excavation or the placement of a manufactured
home on a foundation. Permanent construction does not include land preparation, such as
clearing, grading and filling; installation of streets or walkways; excavation for a
basement, footings, piers or foundations or the erection of temporary forms; or the
installation on the property of accessory buildings, such as garages or sheds not occupied
as dwelling units or not part of the main structure.
Structure means a walled and roofed building that is principally above ground, a
manufactured home, or a gas or liquid storage tank.
Substantial damage means damage of any origin sustained by a structure whereby the
cost of restoring the structure to its before damaged condition would equal or exceed 50
percent of the market value of the structure before the damage occurred.
Substantial improvement means with respect to any property located in an area of special
flood hazard reconstruction, rehabilitation, addition or other improvement of a structure
during a one-year period, the cost of which equals or exceeds 50 percent of the market
value of the structure before the start of construction of the improvement.
For the purposes of this definition, construction is considered to have started when the
first alteration of any wall, ceiling, floor or other structural part of the building
commences, whether or not that alteration affects the external dimensions of the
structure. The term includes structures which have incurred substantial damage,
regardless ofthe actual repair work performed. The term does not, however, include any
project for improvement of a structure to correct existing violations of health, sanitary or
safety code specifications which have been identified by the building official and which
are the minimum necessary to ensure safe living conditions. The term does not include
any alteration of a structure listed on the National Register of Historic Places or the state
inventory of historic places, provided that the alteration will not preclude the structure's
continued designation as a historic structure on such National Register or state inventory.
Variance means a grant of relief from the requirements of this chapter which permits
construction in a manner otherwise prohibited by this chapter where specific enforcement
would result in unnecessary and exceptional hardship.
(Code 1980, 9146.004; Ord. No. 5124, 91,9-5-91; Ord. No. 5265, 91,9-17-92; Ord.
No. 6987-02,9 1,6-6-02; Ord. No. 7213-03, 9 1, 11-20-03)
Sec. 51.04. Interpretation of chapter.
In the interpretation and application of this chapter all provisions shall be considered as
rwater
u~
73
S:\ESM\Staff\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_1_2009 Jinal.docx
; Clearwater
u~
74
S :\ESM\StaftlAMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 "'plan _9_1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
minimum requirements and deemed neither to limit nor repeal any other powers granted
under state laws.
(Code 1980, ~ 146.11)
Sec. 51.05. Warning and disclaimer of liability.
The degree of flood protection required by this chapter is considered reasonable for
regulatory purposes and is based upon scientific and engineering considerations. Larger
floods can and will occur on rare occasions. Flood heights may be increased by manmade
or natural causes. This chapter does not imply that land outside the areas of special flood
hazard or uses permitted within such areas will be free from flooding or flood damages.
This chapter shall not be deemed to create liability on the part of the city or any officer or
employee thereof for any flood damages that may result notwithstanding reliance on this
chapter or any administrative decision made thereunder.
(Code 1980, ~ 146.12)
Sec. 51.06. Penalties for violation of chapter.
A failure to comply with the provisions of this chapter or any of its requirements,
including conditions and safeguards established in connection with grants of variances,
shall constitute a violation. Any person who violates this chapter or fails to comply with
any of its requirements shall, upon a finding of such violation, be fined not more than
$500.00. Each day a violation continues shall be considered a separate offense. Nothing
contained in this section shall prevent the city from taking such other lawful action as is
necessary to prevent or remedy any violation.
(Code 1980, ~ 146.13)
Sec. 51.07. Lands to which this chapter applies.
This chapter shall apply to all areas of special flood hazard within the city.
(Code 1980, ~ 146.005)
Sec. 51.08. Adoption of maps and study.
Federal Emergency Management Agency maps entitled "Flood Insurance Rate Map and
Floodway", and the accompanying study entitled "Flood Insurance Study -Clearwater",
all effective September 3, 2003, and any subsequent revisions, shall be used to provide
the database for this chapter.
(Code 1980, ~ 146.001; Ord. No. 7182-03, ~ 1,8-21-03; Ord. No. 7213-03, ~ 1, 11-20-
03)
Sec. 51.09. Development permit required.
(1) A development permit shall be required in conformance with the provisions of this
chapter prior to the commencement of any development activities.
(2) No structure or land shall be located, extended, converted or structurally altered
without full compliance with the terms of this chapter and other applicable regulations.
(Code 1980, ~ 146.006)
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Sec. 51.10. Administration, permit procedures, duties of building official.
(1) Designation of building official. The building official is hereby appointed to
administer and implement the provisions of this chapter.
(2) Permit procedures. An application for a development permit shall be made to the
building official on forms furnished by him prior to any development activities, and shall
include but not be limited to plans drawn to scale showing the nature, location,
dimensions and elevations of the property; existing or proposed structures; fill; storage of
materials; drainage facilities; and the location of the foregoing. Specifically, the
following information is required:
(a) Application stage.
1. Elevation of the proposed lowest floor, including basement, of all structures.
2. Elevation to which any nonresidential structure will be floodproofed.
3. Certificate from a state registered professional engineer or architect that the
nonresidential floodproofed structure will meet the floodproofing criteria in section
51.32(2).
4. Description of the extent to which any watercourse will be altered or relocated as a
result of proposed development.
5. F or all additions to or alterations of any structure, an appraisal of the market value of
the structure from an MAl (Member, Appraisal Institute) or SRPA (Senior Real Estate
Appraiser) designated appraiser may be provided, along with information showing all
costs involved in the proposed work, including but not limited to materials and labor. If
an appraisal is not provided, then the appraisal of the value of the structure as determined
by the county property appraiser will be used.
6. For all additions to or alterations of any nonconforming structure, information
showing all of the costs of the proposed work shall be provided to the building official.
7. Elevation certificate of the property showing lowest floor and grade elevations duly
certified by a state registered land surveyor.
(b) Construction stage. Provide a floor elevation or floodproofing certification after the
lowest floor is completed, or, in instances where the structure is subject to the regulations
applicable to coastal high hazard areas, after placement of the horizontal structural
members of the lowest floor. Upon placement of the lowest floor or floodproofing by
whatever construction means, or upon placement of the horizontal structural members of
the lowest floor, whichever is applicable, it shall be the duty of the permit holder to
submit to the building official a certificate of the elevation of the lowest floor,
floodproofed elevation, or the elevation of the lowest portion of the horizontal structural
members of the lowest floor, whichever is applicable, as built, in relation to mean sea
level. The certification shall be prepared by or under the supervision of a state registered
land surveyor or, when floodproofing is utilized for a particular building, the certification
shall be prepared by or under the supervision of a state registered professional engineer or
architect, and shall be certified and sealed. Any work undertaken prior to submission of
the certification shall be at the permit holder's risk. The building official shall review the
floor elevation survey data submitted. Deficiencies detected by such review shall be
corrected by the permit holder immediately and prior to further progressive work being
permitted to proceed. Failure to submit the certification or failure to make the corrections
required hereby shall be cause to issue a stop work order for the project.
~
earwater
;:;~
75
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 Jllan _9_1_2009 Jinal.docx
76
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MAN AGEMENT _ PLAN\2009
FMP\2009 -plan _9_ I _2009_ final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
(3) Duties of the building official. The duties of the building official shall include but
not be limited to:
(a) Reviewing all development permit applications to ensure that the permit
requirements of this chapter have been satisfied;
(b) Advising applicants that additional federal or state permits may be required and, if
specific federal or state permit requirements are known, requiring that copies of such
permits are provided and maintained on file with the development permit;
(c) Notifying adjacent communities and the state assistance office for the National Flood
Insurance Program prior to any alteration or relocation of a watercourse, and submitting
evidence of such notification to the Federal Emergency Management Agency;
(d) Ensuring that maintenance is provided within the altered or relocated portion of a
watercourse so that the flood-carrying capacity is not diminished;
(e) Obtaining a certification of the actual elevation of the lowest floor, including the
basement, of all new or substantially improved structures, when certification is required;
(f) Obtaining a certification of the actual elevation to which the new or substantially
improved structures have been floodproofed, when certification is required;
(g) For coastal high hazard areas, obtaining a certification from a state registered
professional engineer or architect that the structure is designed to be securely anchored to
adequately anchored pilings or columns in order to withstand velocity waters and
hurricane wave wash;
(h) For coastal high hazard areas, reviewing plans for adequacy of breakaway walls in
accordance with section 51.32(5);
(i) When floodproofing is utilized for a particular structure, obtaining a certification
from a state registered professional engineer or architect, when certification is required;
U) Making any interpretations which may be needed as to the exact location of
boundaries of the areas of special flood hazard, for example, where there appears to be a
conflict between a mapped boundary and actual field conditions;
(k) Obtaining, reviewing and reasonably utilizing any base flood elevation and floodway
data available from a federal, state or other source whenever base flood elevation data or
floodway data have not been provided as required;
(1) Maintaining all records pertaining to the administration of the provisions of this
chapter;
(m) Promulgating administrative policies and procedures for determining eligible and
ineligible costs for construction or renovation of a structure in the floodplain, consistent
with this chapter and applicable state and federal law. Such administrative policies and
procedures shall be issued before February 1, 1990, and may be amended from time to
time thereafter as circumstances require. Copies thereof shall be provided without cost to
all applicants for building permits in any area of special flood hazard within the city. A
current copy shall be conspicuously posted in a public area of the building official's
office and a current copy shall also be filed in the office of the city clerk.
(Code 1980, S 146.007)
Sec. 51.11. Variances from chapter.
~ Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
(1) The building/flood board of adjustment and appeals shall hear and decide appeals
from decisions of the building official pursuant to this chapter and requests for variances
from the requirements of this chapter. A decision of the board shall be final, subject to
judicial review by common law certiorari in circuit court.
(2) Variances may be granted for the reconstruction, rehabilitation or restoration of
structures listed on the National Register of Historic Places or the state inventory of
historic places, if the proposed reconstruction, rehabilitation or restoration will not result
in the structure losing its historical designation.
(3) In passing upon such applications, the board shall consider all technical evaluations,
all relevant factors, all standards specified in other sections of this chapter; and:
(a) The danger that materials may be swept onto other lands to the injury of others;
(b) The danger to life and property due to flooding or erosion damage;
(c) The susceptibility of the proposed facility and its contents to flood damage and the
effect of such damage on the owner;
(d) The importance of the services provided by the proposed facility to the community;
(e) The necessity of the facility to a waterfront location, in the case of a functionally
dependent facility;
(1) The availability of alternative locations not subject to flooding or erosion damage for
the proposed use;
(g) The compatibility of the proposed use with existing and anticipated development;
(h) The relationship of the proposed use to the comprehensive plan and floodplain
management program for that area;
(i) The safety of access to the property in times of flood for emergency and
nonemergency vehicles;
U) The expected heights, velocity, duration, rate of rise and sediment transport of the
floodwaters and the effects of wave action, if applicable, expected at the site; and
(k) The costs of providing governmental services during and after flood conditions,
including maintenance and repair of public utilities and facilities such as sewer, gas,
electrical and water systems, and streets and bridges.
(4) Conditions for variances:
(a) Variances shall only be issued upon a determination that the variance is the
minimum necessary, considering the flood hazard, to afford relief; and, in the instance of
a historical building, upon a determination that the variance is the minimum necessary so
as not to destroy the historic character and design of the building.
(b) Variances shall only be issued upon a showing of good and sufficient cause, a
determination that failure to grant the variance would result in unnecessary and
exceptional hardship, and a determination that the granting of a variance will not result in
increased flood heights, additional threats to public safety, extraordinary public expense,
the creation of a nuisance or a conflict with existing local laws or ordinances.
(c) Variances shall not be issued within any designated floodway if any increase in flood
levels during the base flood discharge would result.
(5) Upon consideration of the factors listed above, and the purposes of this chapter, the
board may attach such conditions to the granting of variances as it deems necessary to
further the purposes of this chapter.
~ Clearwater
o~
77
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _PLAN\2009
FMP\2009 ylan_9 _1_2009 _finaldocx
78 S:\ESM\Staff\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan_9 _ I _2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
(6) Any applicant to whom a variance is granted shall be given written notice specifying
the difference between the base flood elevation and the elevation to which the structure is
to be built and stating that the cost of flood insurance will be commensurate with the
increased risk resulting from the reduced lowest floor elevation.
(7) The building official shall maintain the records of all appeal actions and shall report
any variances to the Federal Emergency Management Agency upon request.
(Code 1980, S 146.10)
ARTICLE II. FLOOD HAZARD REDUCTION*
*Cross references: Buildings and building regulations generally, ch. 47;
floodproofing certification for the coastal construction zones, S 47.010.
Sec. 51.31. General standards.
In all areas of special flood hazard, the following standards are required,
and compliance with those standards relating to structural stability shall be
certified by an engineer or architect registered in this state:
(1) New construction and substantial improvements shall be anchored to
prevent flotation, collapse or lateral movement of the structure.
(2) Manufactured homes shall be anchored to prevent flotation, collapse or
lateral movement. Methods of anchoring may include but are not limited to use of
over-the-top or frame ties to ground anchors. This standard shall be in addition to
and consistent with applicable state requirements for resisting wind forces.
(3) New construction and substantial improvements shall be constructed with
materials and utility equipment resistant to flood damage.
(4) New construction and substantial improvements shall be constructed by
methods and practices that minimize flood damage.
(5) Electrical, heating, ventilation, plumbing, air conditioning equipment, and
other service facilities shall be located at or above the base flood elevation or
shall be designed or located so as to prevent water from entering or
accumulating within the components during conditions of flooding.
(6) New and replacement water supply systems shall be designed to minimize
or eliminate the infiltration of floodwaters into the system.
(7) New and replacement sanitary sewage systems shall be designed to
minimize or eliminate the infiltration of floodwaters into the systems and
discharges from the systems into floodwaters.
(8) Onsite waste disposal systems shall be located and constructed to avoid
impairment to them or contamination from them during flooding.
(9) Any alteration, repair, reconstruction or improvements to a structure which is
in compliance with the provisions of this chapter shall meet the requirements of
new construction as contained in this chapter.
(Code 1980, S 146.008(a))
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Sec. 51.32. Specific standards.
In all areas of special flood hazard, the following standards are required:
(1) Residential construction (A zone). New construction or substantial
improvement of any residential structure shall have the lowest floor, including the
basement, elevated at or above the base flood elevation. Should solid foundation
perimeter walls be used to elevate a structure, openings sufficient to facilitate the
automatic equalization of flood hydrostatic forces on exterior walls shall be
provided in accordance with the standards set forth in subsection (3) of this
section.
(2) Nonresidential construction (A zone). New construction or substantial
improvement of any commercial, industrial or non-residential structure shall have
the lowest floor, including the basement, elevated at or above the base flood
elevation. Structure located in all A zones may be floodproofed in lieu of being
elevated, provided that all areas of the structure, together with attendant utilities,
below the required elevation are watertight with walls substantially impermeable
to the passage of water and use structural components having the capability of
resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A
state registered professional engineer or architect shall certify that the standards
of this subsection are satisfied.
(3) Elevated buildings (A zone). New construction or substantial improvements
of elevated buildings that include fully enclosed areas formed by the foundation
and other exterior walls below the base flood elevation shall be designed to
preclude finished living space and designed to allow for the entry and exit of
floodwaters to automatically equalize hydrostatic flood forces on exterior walls.
(a) Designs for complying with this requirement shall either be certified by a
state registered professional engineer or architect or meet the following minimum
criteria:
1. Provide a minimum of two openings having a total net area of not less than
one square inch for every square foot of enclosed area subject to flooding;
2. The bottom of all openings shall be no higher than one foot above grade; and
3. Openings may be equipped with screens, louvers, valves or other coverings
or devices provided they permit the automatic flow of floodwaters in both
directions.
(b) Electrical, plumbing and other utility connections are prohibited below the
base flood elevation except as may be required by other codes, or where there is
a more practical location consistent with the intent of another code, and approved
by the building official.
(c) Access to the enclosed area shall be the minimum necessary to allow for
parking of vehicles (garage door), limited storage of maintenance equipment
used in connection with the premises (standard exterior door), and entry to the
living area (stairway or elevator).
(d) The interior portion of such enclosed area shall not be partitioned or finished
into separate rooms.
(4) Manufactured homes and RV requirements.
~
o
rwater
>
0~
79
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009_ finaldocx
80
S :\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 ylan _9_1_2009 jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
(a) New and existing manufactured home parks and subdivisions, new and
existing manufactured homes not located within a new or existing manufactured
home park and subdivision, and recreational vehicles that are located or placed
or substantially improved in either areas of special flood hazard or in coastal high
hazard areas as defined in this chapter shall conform to all requirements of 44
CFR 59 and 60, effective November 1, 1989, and for the purpose of this chapter
such definitions and requirements as are contained therein are adopted in this
section by reference unless specifically set forth in this section.
(b) No floodplain management regulations will apply to a recreational vehicle if
the recreational vehicle was onsite for fewer than 180 consecutive days or was
fully licensed as a motor vehicle and ready for highway use.
(5) Floodways. Located within areas of special flood hazard are areas
designated as f1oodways. Because the floodway is an extremely hazardous area
due to the velocity of floodwaters and erosion potential, the following standards
shall apply in any floodway:
(a) Encroachments, including fill, new construction, substantial improvements
and other developments, are prohibited unless certification, with supporting
technical data, by a state registered professional engineer is provided
demonstrating that the encroachments shall not result in any increase in flood
levels during the occurrence of the base flood discharge.
(b) All new construction and substantial improvements shall comply with all
applicable flood hazard reduction provisions of this section.
(c) The placement of manufactured homes is prohibited except in an existing
manufactured home park or subdivision; however, a replacement manufactured
home may be placed on a lot in an existing manufactured home park or
subdivision provided the anchoring standards and the elevation standards set
forth in this section are met.
(6) Coastal high hazard areas (V zones). Located within the areas of special
flood hazard are areas designated as coastal high hazard areas. Because these
areas have special flood hazards associated with wave wash, the following
standards are required:
(a) All buildings or structures shall be located landward of the coastal
construction control line.
(b) All buildings or structures shall be elevated so that the bottom of the lowest
supporting horizontal structural member, excluding pilings or columns, is located
at or above the base flood elevation level, with all space below the lowest
supporting member open so as not to impede the flow of water. Breakaway walls
may be permitted if designed to wash away in the event of abnormally high tides
or wave action and in accordance with subsection (6)(h) of this section.
(c) All buildings or structures shall be securely anchored on pilings or columns.
(d) All pilings and columns and the attached structures shall be anchored to
resist flotation, collapse and lateral movement due to the effect of wind and water
loads acting simultaneously on all building components. The anchoring and
support system shall be designed with wind and water loading values which
~ ..... rwater
G~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
equal or exceed the 1 DO-year mean recurrence interval or one percent annual
chance flood.
(e) A state registered professional engineer or architect shall certify that the
design, specifications and plans for construction are in compliance with the
provisions of subsections (6)(b), (c) and (d) of this section.
(f) There shall be no fill used as structural support. Limited noncompacted fill
may be used around the perimeter of a building for landscaping or aesthetic
purposes provided the fill will wash out from storm surge, thereby rendering the
building free of obstruction, prior to generating excessive loading forces, ramping
effects or wave deflection. The building official shall approve design plans for
landscaping/aesthetic fill only after the applicant has provided an analysis by an
engineer, architect or soil scientist which demonstrates that the following factors
have been fully considered:
1. Particle composition of fill material does not have a tendency for excessive
natural compaction.
2. Volume and distribution of fill will not cause wave deflection to adjacent
properties.
3. Slope of fill will not cause wave runup or ramping.
(g) There shall be no alteration of sand dunes or mangrove stands which would
increase potential flood damage.
(h) Nonsupporting breakaway walls, open wood latticework or mesh screening
shall be allowed below the base flood elevation provided they are not part of the
structural support of the building and are designed so as to break away, under
abnormally high tides or wave action, without damage to the structural integrity of
the building on which they are to be used and provided the following design
specifications are met:
1. Design safe loading resistance of each wall shall be not less than ten nor
more than 20 pounds per square foot; or
2. If more than 20 pounds per square foot, a state registered professional
engineer or architect shall certify that the design wall collapse would result from a
water load less than that which would occur during the base flood event, and the
elevated portion of the building and supporting foundation system shall not be
subject to collapse, displacement or other structural damage due to the effects of
wind and water loads acting simultaneously on all building components during
the base flood event. Maximum wind and water loading values to be used in this
determination shall each have a one percent chance of being equalled or
exceeded in any given year or 1 DO-year mean recurrence interval.
(i) If breakaway walls are utilized, such enclosed space shall not be designed to
be usable for human habitation but shall be designed to be usable only for
parking of vehicles, building access or limited storage of maintenance equipment
used in connection with the premises.
0) Prior to construction, plans for any structures that will have breakaway walls
shall be submitted to the building official for approval.
(k) Any alteration, repair, reconstruction or improvement to a structure shall not
enclose the space below the lowest floor except with breakaway walls.
; Clearwater
u~
81
S\ESM\Staff\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 _final.docx
o~'
82
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 --plan _9_1_2009 JinaLdocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
(I) The placement of manufactured homes is prohibited except in an existing
manufactured home park or subdivision; however, a replacement manufactured
home may be placed on a lot in an existing manufactured home park or
subdivision provided the anchoring standards and the elevation standards set
forth in this section are met.
(Code 1980, S 146.008(b); Ord. No. 5558-94, S 1,5-5-94; Ord. No. 7213-03, S 1,
11-20-03)
Sec. 51.33. Streams without established base flood elevations or
floodways.
(1) Within the areas of special flood hazard where small streams exist where
base flood data have been provided but where no floodways have been
provided, the following standards apply:
No encroachments, including fill material or structures, shall be located less than
20 feet from the top of the stream bank unless certification by a state registered
professional engineer is provided demonstrating that such encroachments shall
not result in any increase in flood levels during the occurrence of the base flood
discharge.
(2) Within the areas of special flood hazard where small streams exist but
where no base flood data have been provided and where no floodways have
been provided, the following standards apply:
New construction or substantial improvements of structures shall be elevated or
flood proofed to elevations established by the building official utilizing data
available from a federal, state or other source.
(Code 1980, S 146.008(c); Ord. No. 7213-03, S 1,11-20-03)
Sec. 51.34. Subdivision proposals.
All proposed subdivisions, including but not limited to manufactured home
parks and subdivisions and other proposed developments consisting of at least
50 lots or five acres, or both, shall be reviewed by the city engineer to determine
that the following requirements have been or will be satisfied:
(1) All subdivision proposals shall be consistent with the need to minimize flood
damage.
(2) All subdivision proposals shall have public utilities and facilities, such as
sewer, gas, electrical and water systems, located and constructed so as to
minimize flood damage.
(3) All subdivision proposals shall have adequate drainage provided so as to
reduce exposure to flood hazards.
(4) Base flood elevation data shall be provided.
(Code 1980, S 146.008(d))
Sec. 51.35. Areas of shallow flooding (AO zones).
rwater
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Located within the areas of special flood hazard are areas designated as
shallow flooding areas. Because these areas have special flood hazards
associated with base flood depths of one to three feet, where a clearly defined
channel does not exist and where the path of flooding is unpredictable and
indeterminate, the following standards are required:
(1) All new construction and substantial improvements of residential structures
shall have the lowest floor, including the basement, elevated to the depth number
specified on the flood insurance rate map, in feet, above the highest adjacent
grade. If no depth number is specified, the lowest floor, including the basement,
shall be elevated at least two feet above the highest adjacent grade.
(2) All new construction and substantial improvements of nonresidential
structures shall:
(a) Have the lowest floor, including the basement, elevated to the depth number
specified on the flood insurance rate map, in feet, above the highest adjacent
grade. If no depth number is specified, the lowest floor, including the basement,
shall be elevated at least two feet above the highest adjacent grade; or
(b) Together with attendant utility and sanitary facilities, be completely
flood proofed to or above that level so that any space below that level is
watertight with walls substantially impermeable to the passage of water and with
structural components having the capability of resisting hydrostatic and
hydrodynamic loads and effects of buoyancy.
(Code 1980, 9 146.008(e))
~ Clearwater
o~
83
S:\ESM\Staff\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_1_2009 _final.docx
84
S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_ I _2009 _finaIdocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix E
Community Development Code
Article 4 Division 13 - Clearing and Grubbing
; Clearwater
o~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
DIVISION 13. LAND CLEARING AND GRUBBING
Section 4-1301. Permit required.
A land clearing and grubbing permit is required in order to clear or grub any land in the
city. No land clearing and grubbing permit shall be granted prior to issuance of a Level
One or Level Two approval in accordance with the provisions of Article 4, Divisions 3
and 4. If no Level One or Level Two approval is required a land clearing and grubbing
permit shall be granted if the permit request is in conformance with the provisions of this
division or the terms of a prior approval.
(Ord. No. 6526-00, ~ 1,6-15-00; Ord. No. 6928-02, ~ 109,5-2-02)
Section 4-1302. Application/appeal.
A. An application for a clearing and grubbing permit shall be submitted to the
community development coordinator applications forms to be provided, accompanied by
the fee required by Section 4-202(E), and including the following information:
1. A legible scaled drawing or scaled aerial photograph and a tree survey showing
property boundaries, physical or natural features, and limits of the proposed work.
2. Purpose of clearing and/or grubbing.
3. Types of equipment to be used.
4. General description of existing vegetation, topography, and any surface waters
present.
5. Method of debris disposal.
6. Anticipated date of commencement and completion of work.
7. Methods of soil erosion and sedimentation control to be undertaken during earthwork
activities and the means and timing of soil stabilization subsequent to the completion of
the clearing and grubbing activities.
8. No tree statement, no tree removal permit required or tree removal permit required.
B. A denial of a clearing and grubbing permit may be appealed in the manner provided
in Article 4 Division 5.
(Ord. No. 6526-00, ~ 1, 6-15-00)
Section 4-1303. Criteria for issuance.
In determining whether or not to issue a permit to clear or grub land, the community
development coordinator shall consider:
A. The need for vegetation removal on the property for purposes of land surveying or
land preparation for development or other economic uses.
B. Whether visual access is necessary to comply with the tree survey requirements in
Section 4-1302.
C. Whether the applicant has filed a "no tree verification" form or "no tree removal
permit required verification" form stating that there are no protected trees on the site or
that protected trees exist but do not need to be removed for construction purposes.
D. The applicant has provided protective barriers around all protected trees on the site.
E. Whether the applicant has provided soil erosion and sedimentation control as
required in Article 3, Division 7.
(Ord. No. 6526-00, ~ 1, 6-15-00)
~.Clearwater
u~
85
S\ESM\Staff\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan_9 _1_2009 _final.docx
86
S\ESM\StafflAMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 jllan_9 _1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix F
Engineering Department's Erosion and Siltation Control Policy
; Cllarwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
City of Clearwater
Florida
Erosion and Siltation
Control Policy
"IIIIIII,,<tIJI:.
~._"%~~L OF!,yt ~~
*~~ 1 ~"
le:s .....'\ , ~ \
I I
Ie? ~I
\~ - ~I
~4'!; 'L '11-
~""lldl'
Requirements for ALL construction
~ Clearwater
u~
87 S:\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009_ final.docx
; Clearwater
u~
88
S :\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --"Ian _9_1_2009 _final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
sites regardless of type or size of'
construction activity
EROSION AND SILTATION CONTROL POLICY
The following Erosion and Siltation Control Standards and procedures shall apply to all
physical improvement projects, which are subject to the rules and regulations of the City of
Clearwater.
1. SITE PLAN REVIEW: All erosion and siltation control methods to be employed
during construction shall be shown on the final construction plans submitted for approval to
the City.
2. LAND CLEARING AND GRUBBING: All projects that will denude soil (i.e., one
that requires grass and brush removal or asphalt, concrete and building removal prior to
actual construction) or that will involve ground alteration such as excavation shall be
required to have a grubbing and clearing permit prior to any such work (per Part 1, Article 4,
Division 1301, Community Development Code).
3. STABILIZATION OF DENUDED AREAS: No disturbed area may be denuded for
more than thirty (30) calendar days unless otherwise authorized by the City. During inactive
construction periods, denuded areas shall be covered by mulches such as straw, hay, filter
fabric, seed and mulch, sod, or some other permanent vegetation. Within sixty (60) calendar
days after final grade is established on any portion of a project site, that portion of the site
shall be provided with established permanent soil stabilization measures per the original site
plan, whether by impervious surface or landscaping.
4. PROTECTION AND STABILIZATION OF SOIL STOCKPILES: Fill material
stockpiles shall be protected at all times by on-site drainage controls which prevent erosion
of the stockpiled material. Control of dust from such stockpiles may be required, depending
upon their location and the expected length of time the stockpiles will be present. In no case
shall an unstabilized stockpile remain after thirty (30) calendar days.
5. PROTECTION OF EXISTING STORM SEWER SYSTEMS: During construction,
all storm sewer inlets in the vicinity of the project shall be protected by sediment traps such
as secured hay bales, sod, stone, etc., which shall be maintained and modified as
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
required by construction progress, and which must be approved by the City before
installation.
6. SEDIMENT TRAPPING MEASURES: Sediment basins and traps, perimeter berms,
filter fences, berms, sediment barriers, vegetative buffers and other measures intended to
trap sediment and/or prevent the transport of sediment onto adjacent properties, or into
existing water bodies, must be installed, constructed or, in the case of vegetative buffers,
protected from disturbance, as a first step in the land alteration process. Such systems shall
be fully operative and inspected by the City before any other disturbance of the site begins.
Earthen structures including but not limited to berms, earth filters, dams or dikes shall be
stabilized and protected from drainage damage or erosion within one week of installation.
7. SEDIMENTATION BASINS: Areas of 3 acres or more shall be required to have
temporary sedimentation basins as a positive remedy against downstream siltation and will
be shown and detailed on construction plans. During development, permanent detention
areas may be used in place of silt basins, provided they are maintained to the satisfaction of
the City. The contractor will be required to prohibit discharge of silt through the outfall
structure during construction of any detention area and will be required to clean out the
detention area before installing any permanent subdrain pipe. In addition, permanent
detention areas must be totally cleaned out and operating properly at final inspection and at
the end of the one year warranty period. When temporary sedimentation basins are used,
they shall be capable at all times of containing at least one (1) cubic foot of sediment for
each one hundred (100) square feet of area tributary to the basin. Such capacity shall be
maintained throughout the project by regular removal of sediment from the basin.
8. WORKING IN OR CROSSING WATERWAYS OR WATERBODIES: Land
alteration and construction shall be minimized in both permanent and intermittent
waterways and the immediately adjacent buffer of25 feet from top of bank of the waterway.
Construction equipment and vehicles shall be kept out of waterways and the buffer area
whenever possible, and barriers shall be used to prevent access. Where in-channel work
cannot be avoided, precautions must be taken to stabilize the work area during land
alteration, development and/or construction to minimize erosion. If the channel and buffer
area are disturbed during land alteration, they must be stabilized within three (3) calendar
days after the in-channel work is completed.
Silt curtains or other filter/siltation reduction devices must be installed on the downstream
side of the in-channel alteration activity to eliminate impacts due to increased turbidity.
(See Index #609 & 610). Wherever stream crossings are required, properly sized temporary
culverts shall be provided by the contractor and removed when construction is completed.
The area of the crossing shall be restored to a condition as nearly as possible equal to that,
which existed prior to any construction activity.
9. SWALES, DITCHES AND CHANNELS: All swales, ditches and channels leading
from the site shall be sodded within three (3) days of excavation. All other interior swales,
~ Clearwater
o~
89
S\ES M\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 -p1an_ 9 _1_2009 _finaldocx
90
S :\ESM\StafflAMcKinney\2009 _FLOODPLAIN_MAN AGEMENT ]LAN\2009
FMP\2009 ylan _ 9 _ I _2009 jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
etc., including detention areas will be sodded pnor to Issuance of a Certificate of
Occupancy.
10. UNDERGROUND UTILITY CONSTRUCTION: The construction of underground
utility lines and other structures shall be done in accordance with the following standards:
a. No more than 400 lineal feet of trench shall be open at anyone time;
b. Wherever consistent with safety and space consideration, excavated material
shall be cast to the uphill side of trenches. Trench material shall not be cast
into or onto the slopes of any stream, channel, road ditch or waterway.
c. Storm sewer inlets in the vicinity shall be protected.
11. MAINTENANCE: All erosion and siltation control devices shall be checked
regularly, especially after each rainfall and will be cleaned out and/or repaired as required.
12. COMPLIANCE: Failure to comply with the aforementioned requirements may result
in a fine and/or more stringent enforcement procedures such as (but not limited to) issuance
ofa "Stop Work Order". (Part 1, Article 7, Section 101, Community Development Code)
City of Clearwater Standard Detail Drawings No. 601-607 are examples of accepted
methods that may be used or required to control erosion and siltation.
13. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE & EXIT
Definition - A stone stabilized pad located at points of vehicular ingress and egress on a
construction site.
Purpose - To stabilize entrances to the construction site and reduce the amount of sediment
transported onto public roads by motor vehicles or runoff.
Conditions Where Practice Applies - Wherever traffic will be leaving a construction site
and moving directly onto a public road or other paved area.
Plannine Considerations - Construction entrances provide an area where mud can be
removed from construction vehicle tires before they enter a public road. If the action of the
vehicle traveling over the gravel pad is not sufficient to remove most of the mud, then the
tires must be washed before the vehicle enters a public road. If washing is used, provisions
must be made to intercept the wash water and trap the sediment before it is carried off-site.
Construction entrances should be used in conjunction with the stabilization of construction
roads to reduce the amount of mud picked up by construction vehicles.
Desien Criteria -
; Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Aggregate Size - FDOT No.1 Coarse Aggregate (1.5 - 3.5 inch stone)(4 -9 cm) should be
used. Wood chips may be used for single family residential construction, provided that they
can be prevented from floating away in a storm.
Entrance Dimensions - The aggregate layer must be at least 6 inches (15 cm) thick. It must
extend the full width of the vehicular ingress and egress area. The length of the entrance
must be at least 50 feet (20 m). The entrance must widen at its connection to the roadway in
order to accommodate the turning radius of large trucks. (See Index # 60 I).
14. DEWATERING
Definition - Lowering the water table by means of pumping.
Purpose - To allow the construction of structural and stormwater improvements by
removing water from excavation areas and allowing construction by conventional "dry"
methods.
Plannine Considerations - The major planning consideration in dewatering is disposal of
removed water. Volume, quality, and topography are the factors governing the method and
destination of removed water. Discharge from well-point dewatering is relatively clear
except for the initial discharge after installation or inactivity. Water pumped from a sump
hole is thoroughly sediment laden and must always be treated. Turbid water must either be
filtered before leaving the site or must be impounded onsite and allowed to settle. In flat
terrain it is sometimes more economical to impound relatively clean water rather than pipe it
long distances to a receiving water body.
Specifications - The two most common methods of dewatering used in Florida are well-
point systems and sump pumps. A well-point system consists of one or more rows of small
2" (5 cm) collector pipes, which are jetted vertically into the ground near the proposed
excavation. The small pipes are connected by a larger 6" (15 cm) manifold pipe, which is
connected to the pump and discharge line. The sump method is simply a hole in the ground
with a pump drawing all of the water flowing into the hold. Excess water is conveyed to the
sump by open ditches or perforated pipes embedded in sand or gravel.
Sumps and Ditches - The water table is lowered by ditching and conveying water to a
lowered sump hole. Water pumped from a sump hole is usually heavily laden with
sediments. Water flowing over disturbed and saturated ground detaches and transports all
sizes of soil particles into the sump pit to be sucked up by the pump. Saturated liquid soil
(mud) is also drawn into the pump. The discharged water must be treated before release into
a receiving water body or stormwater system. Placing haybales around the pump intake or
outlet is not sufficient filtration by itself. Turbid water must either be impounded long
enough for effective settling of fines, or filtered through a temporary filter or sediment tank.
Initially the water may percolate freely into the ground, however, this will diminish as the
fine particles settle and clog the surface layer of soil. In situations which
~ @learwater
~~
91
S :IESM\Staff\AMcKinney\2009 JLOODPLA1N _MAN AGEMENT ]LAN12009
FMPI2009 -p1an_9 _1_2009 Jinaldocx
92
S:\ESM\StafflAMcKinney\2009 JLOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 ylan_9 _1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
preclude the use of filtration or settlement facilities, and turbid water is discharged directly
into a water body, a suitably designed floating turbidity barrier must be used. Note that this
method does not remove any sediments, it merely allows for dilution to lower the turbidity
level.
Horizontal Wells - This system also consists of a series of ditches leading to a sump hole
or pump. The ditches are filled with sand or gravel surrounding a perforated pipe. A
geotextile may also be used to prevent excessive migration of fines into the system. The
discharged water must be treated before release as described below.
Well-point Systems - The well-point system is the preferred system for dewatering and
should be used whenever possible. The initial discharge yields the sediments displaced by
the installation of the small collector pipes. This can be directed into the excavation, a small
settling or filtration facility, or larger temporary impoundment. Thereafter the water is
generally clear ground water and may be discharged into a receiving water body provided
that there is suitable conveyance.
Maintenance -
1. Any water impoundment must be inspected daily to prevent failure of dikes, berms,
or control structures. Minor problems should be repaired at once. Major problems
will require a redesign and plan modification.
2. Any filtration device must be inspected and cleaned frequently. The discharge
should be monitored daily and whenever the pumps are started. Inspection and
maintenance of the system are best performed when the facility is dry. The first
signs of diminished performance should be an alarm that maintenance is required. If
the facility will no longer drain itself, the untreated water must be pumped back to
its source, rather than by-passing the facility and discharging to the water body or
stormwater system.
3. Floating turbidity barriers shall be maintained as per FLOATING TURBIDITY
BARRIER
15. FLOATING TURBIDITY BARRIER
Definition - A floating geotextile material which minimizes sediment transport from a
disturbed area adjacent to or within a body of water.
Purpose - To provide sedimentation protection for a watercourse from up-slope land
disturbance where conventional erosion and sediment controls cannot be used, or from
dredging or filling within the watercourse.
Conditions where Practice Applies - Applicable to non-tidal and tidal watercourses
; €learwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
where intrusion into the watercourse by construction activities has been permitted and
subsequent sediment movement is unavoidable.
Plannin2: Considerations - Soil loss into a watercourse results in long-term suspension of
sediment. In time, the suspended sediment may travel large distances and affect
widespread areas. A turbidity curtain is designed to deflect and contain sediment within a
limited area and provide enough residence time so that soil particles will fall out of
suspension and not travel to other areas.
Turbidity curtain types must be selected based on the flow conditions within the water body,
whether it be a flowing channel, lake, pond, or a tidal watercourse. The specifications
contained within this practice pertain to minimal and moderate flow conditions where the
velocity of flow may reach 5 feet (1.5 m) per second (or a current of approximately 3 knots).
For situations where there are greater flow velocities or currents, a qualified engineer and
product manufacturer should be consulted.
Consideration must also be given to the direction of water movement in channel flow
situations. Turbidity curtains are not designed to act as water impoundment dams and
cannot be expected to stop the flow of a significant volume of water. They are designed and
installed to trap sediment, not to halt the movement of water itself. In most situations,
turbidity curtains should not be installed across channel flows.
In tidal or moving water conditions, provisions must be made to allow the volume of water
contained within the curtain to change. Since the bottom of the curtain is weighted and
external anchors are frequently added, the volume of water contained within the curtain will
be much greater at high tide verses low tide and measures must be taken to prevent the
curtain from submerging. In addition to allowing slack in the curtain to rise and fall, water
must be allowed to flow through the curtain if the curtain is to remain in roughly the same
place and maintain the same shape. Normally, this is achieved by constructing part of the
curtain from a heavy woven filter fabric. The fabric allows the water to pass through the
curtain, but retains the sediment particles. Consideration should be given to the volume of
water that must pass through the fabric and sediment particle size when specifying fabric
permeability .
Sediment which has been deflected and settled out by the curtain may be removed if so
directed by the on-site inspector or the permitting agency. However, consideration must be
given to the probable outcome of the procedure - will it create more of a sediment problem
by resuspension of particles and by accidental dumping of the material by the equipment
involved? It is, therefore, recommended that the soil particles trapped by a turbidity curtain
only be removed if there has been a significant change in the original contours of the
effected area in the watercourse. Regardless of the decision made, soil particles should
always be allowed to settle for a minimum of 6 - 12 hours before their removal by
equipment or before removal of a turbidity curtain.
; Qlearwater
o~
93
S :\ESM\S taft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 ylan_9 _1_2009 _finaI.docx
94
S :\ESM\Staff\AMcKinney\2009 ]LOO DPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 ""plan _9_1_2009 jina1.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
It is imperative that the intended function of the other controls in this chapter, to keep
sediment out of the watercourse, be the strategy used in every erosion control plan.
However, when proximity to the watercourse makes successfully mitigating sediment loss
impossible, the use of the turbidity curtain during land disturbance is essential. Under no
circumstances shall permitted land disturbing activities create violations of water quality
standards.
Desi2D Criteria
1. Type I configuration (See Index # 609) should be used in protected areas where
there is no current and the area is sheltered from wind and waves.
2. Type II configuration (See Index # 609) should be used in areas where there may be
small to moderate current running (up to 2 knots or 3.5 feet (1 m) per second) and/or
wind and wave action can affect the curtain.
3. Type III configuration (See Index # 609) should be used in areas where considerable
current (up to 3 knots or 5 feet (1.5 m) per second) may be present, where tidal
action may be present, and/or whether the curtain is potentially subject to wind and
wave action.
4. Turbidity curtains should extend the entire depth of the watercourse whenever the
watercourse in question is not subject to tidal action and/or significant wind and
wave forces. This prevents silt-laden water from escaping under the barrier,
scouring and resuspending additional sediments.
5. In tidal and/or wind and wave action situations, the curtain should never be so long
as to touch the bottom. A minimum I-foot (30-cm) "gap" should exist between the
weighted lower end of the skirt and the bottom at "mean" low water. Movement of
the lower skirt over the bottom due to tidal reverses or wind and wave action on the
flotation system may fan and stir sediments already settled out.
6. In tidal and/or wind and wave action situations, it is seldom practical to extend a
turbidity curtain depth lower than 10 to 12 feet (3 to 4 m) below the surface, even in
deep water. Curtains which are installed deeper than this will be subject to very
large loads with consequent strain on curtain materials and the mooring system. In
addition, a curtain installed in such a manner can "billow up" toward the surface
under the pressure of the moving water, which will result in an effective depth,
which is significantly less than the skirt depth.
7. Turbidity curtains should be located parallel to the direction of flow of a moving
body of water. Turbidity curtains should not be placed across the main flow of a
significant body of moving water.
; Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
8. When sizing the length of the floating curtain, allow an additional 10 - 20% variance
in the straight line measurements. This will allow for measuring errors, make
installing easier and reduce stress from potential wave action during high winds.
9. An attempt should be made to avoid an excessive number of joints in the curtain; a
minimum continuous span of 50 feet (15 m) between joints is a good "rule of
thumb. "
10. For stability reasons, a maximum span of 100 feet (30 m) between anchor or stake
locations is also a good rule to follow.
11. The ends of the curtain, both floating upper and weighted lower, should extend well
up into the shoreline, especially if high water conditions are expected. The ends
should be secured firmly to the shoreline to fully enclose the area where sediment
may enter the water.
12. When there is a specific need to extend the curtain to the bottom of the watercourse
in tidal or moving water conditions, a heavy woven pervious filter fabric may be
substituted for the normally recommended impervious geotextile. This creates a
"flow-through" medium, which significantly reduces the pressure on the curtain and
will help to keep it in the same relative location and shape during the rise and fall of
tidal waters.
13. Typical alignments of turbidity curtains can be seen in (Index # 610). The number
and spacing of external anchors may vary depending on current velocities and
potential wind and wave action; manufacturer's recommendations should be
followed.
14. Be certain that the type, location, and installation of the barrier is as shown on the
approved plan and permit. Additional permits may be required in navigable
waterways, especially when the barrier creates an obstruction.
16. CONSTRUCTION SPECIFICATIONS
Materials
1. Barriers should be a bright color (yellow or "international" orange are
recommended) that will attract the attention of nearby boaters.
2. The curtain fabric must meet the minimum requirements.
3. Seams in the fabric shall be either vulcanized welded or sewn, and shall develop the
full strength of the fabric.
rwater
(j~
95
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _ PLAN\2009
FMP\2009 ylan _9 _1_2009 Jinal.docx
96
S :\ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
4. Floatation devices shall be flexible, buoyant units contained in an individual
floatation sleeve or collar attached to the curtain. Buoyancy provided by the
floatation units shall be sufficient to support the weight of the curtain and maintain a
freeboard of at least 3 inches (8 cm) above the water surface level. (See Index #
609).
5. Load lines must be fabricated into the bottom of all floating turbidity curtains. Type
II and Type III must have load lines also fabricated into the top of the fabric. The
top load line shall consist of woven webbing or vinyl-sheathed steel cable and shall
have a break strength in excess of 10,000 pounds (4.5 t). The supplemental (bottom)
load-line shall consist of a chain incorporated into the bottom hem of the curtain of
sufficient weight to serve as ballast to hold the curtain in a vertical position.
Additional anchorage shall be provided as necessary. The load lines shall have
suitable connecting devices, which develop the full breaking strength for connecting
to load lines in adjacent sections (See Index # 609, which portray this orientation).
6. External anchors may consist of 2 x 4 (5 x 10 cm) or 2 - 1/2 inch (6 cm) minimum
diameter wooden stakes, or 1.33 pounds/linear foot (2 kg/m) steel posts when Type I
installation is used; when Type II or Type III installations are used, bottom anchors
should be used.
7. Bottom anchors must be sufficient to hold the curtain in the same position relative to
the bottom of the watercourse without interfering with the action of the curtain. The
anchor may dig into the bottom (grappling hook, plow or fluke-type) or may be
weighted (mushroom type) and should be attached to a floating anchor buoy via an
anchor line. The anchor line would then run from the buoy to the top load line of the
curtain. When used with Type III installations, these lines must contain enough
slack to allow the buoy and curtain to float freely with tidal changes without pulling
the buoy or curtain down and must be checked regularly to make sure they do not
become entangled with debris. As previously noted, anchor spacing will vary with
current velocity and expected wind and wave action; manufacturer's
recommendations should be followed. See orientation of external anchors and
anchor buoys for tidal installation in Index # 610.
Installation
1. In the calm water of lakes or ponds (Type I installation) it is usually sufficient to
merely set the curtain end stakes or anchor points (using anchor buoys if bottom
anchors are employed), then tow the curtain in the furled condition out and attach it
to these stakes or anchor points. Following this, any additional stakes or buoyed
anchors required to maintain the desired location of the curtain may be set and these
anchor points made fast to the curtain. Only then, the furling lines should be cut to
let the curtain skirt drop.
~ Clearwater
u~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
2. In rivers or in other moving water (Type II and Type III installations) it is important
to set all the curtain anchor points. Care must be taken to ensure that anchor points
are of sufficient holding power to retain the curtain under the expected current
conditions, before putting the furled curtain into the water. Anchor buoys should be
employed on all anchors to prevent the current from submerging the floatation at the
anchor points. If the moving water into which the curtain is being installed is tidal
and will subject the curtain to currents in both directions as the tide changes, it is
important to provide anchors on both sides ofthe curtain for two reasons:
a.) Curtain movement will be minimized during tidal current reversals.
When the anchors are secure, the furled curtain should be secured to the upstream
anchor point and then sequentially attached to each next downstream anchor point
until the entire curtain is in position. At this point, and before unfurling, the "lay" of
the curtain should be assessed and any necessary adjustments made to the anchors.
Finally when the location is ascertained to be as desired, the furling lines should be
cut to allow the skirt to drop.
3. Alwavs attach anchor lines to the flotation device, not to the bottom of the curtain.
The anchoring line attached to the floatation device on the downstream side will
provide support for the curtain. Attaching the anchors to the bottom of the curtain
could cause premature failure of the curtain due to the stresses imparted on the
middle section of the curtain.
4. There is an exception to the rule that turbidity curtains should not be installed across
channel flows; it occurs when there is a danger of creating a silt buildup in the
middle of a watercourse, thereby blocking access or creating a sand bar. Curtains
have been used effectively in large areas of moving water by forming a very long-
sided, sharp "V" to deflect clean water around a work site, confine a large part of the
silt-laden water to the work area inside the "V" and direct much of the silt toward the
shoreline. Care must be taken, however, not to install the curtain perpendicular to
the water current.
5. See Index # 610 for typical installation layouts.
6. The effectiveness of the barrier can be increased by installing two parallel
curtains, separated at regular intervals by 10' (3 m) long wooden boards or
lengths of pipe.
Removal
1. Care should be taken to protect the skirt from damage as the turbidity curtain is
dragged from the water.
; Clearwater
u~
97
S :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_1_2009_ final.docx
98 s :\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
2. The site selected to bring the curtain ashore should be free of sharp rocks, broken
cement, debris, etc., so as to minimize damage when hauling the curtain over the
area.
3. If the curtain has a deep skirt, it can be further protected by running a small boat
along its length with a crew installing furling lines before attempting to remove the
curtain from the water.
Maintenance
1. The developer/owner shall be responsible for maintenance of the filter curtain for the
duration of the project to ensure the continuous protection of the watercourse.
2. Should repairs to the geotextile fabric become necessary, there are normally repair
kits available from the manufacturers; manufacturer's instructions must be followed
to ensure the adequacy of the repair.
3. When the curtain is no longer required as determined by the inspector, the curtain
and related components shall be removed in such a manner as to minimize turbidity.
Sediment shall be removed and the original depth (or plan elevation) restored before
removing the curtain. Remaining sediment shall be sufficiently settled before
removing the curtain. Any spoils must be taken to an upland area and stabilized.
Sheet Flow Application: Silt Fence
This sediment barrier uses standard strength or extra strength synthetic filter fabrics. It is
designed for situations in which only sheet or overland flows are expected. (See Index #
607).
1. The height of a silt fence shall not exceed 36 inches (90 cm). Higher fences may
impound volumes of water sufficient to cause failure of the structure.
2. The filter fabric shall be purchased in a continuous roll cut to the length of the
barrier to avoid the use of joints. When joints are necessary, filter cloth shall be
spliced as described in Figure 6.
3. Posts shall be spaced a maximum of 10 feet (3 m) apart at the barrier location and
driven securely into the ground a minimum of 12 inches (30 cm). When extra
strength fabric is used without the wire support fence, post spacing shall not exceed
6 feet (1.8 m).
4. A trench shall be excavated approximately 4 inches (10 cm) wide and 4 inches (10
cm) deep along the line of posts and upslope from the barrier.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
5. When standard strength filter fabric is used, a wire mesh support fence shall be
fastened securely to the upslope side of the posts using heavy duty wire staples at
least 1 inch (25 mm) long, tie wires, or hog rings. The wire shall extend into the
trench a minimum of 2 inches (5 cm) and shall not extend more than 36 inches (90
cm) above the original ground surface.
6. The standard strength filter fabric shall be stapled or wired to the fence, and 8 inches
(20 cm) of the fabric shall be extended into the trench. The fabric shall not extend
more than 36 inches (90 cm) above the original ground surface.
99 S :\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9 _1_2009_ final.docx
City of Clearwater
Floodplain Management Plan
~ ~IL ~
1.&.1 ",ag I!J
<t; ~ ",I ~
go:::
cr<
OO-z
r;:' 1.&.1 0....1 ~
.0 (7j~w
cr o<t;al
~ 15o::cr
<t; t:l 0
3: >-....11-
0:: cr 0 a..
i:5 ~ ~ t$
....1 Oz 0::
UC) a..o~
~~ ~u~
>-0:::
1-1.&.1
-1.&.1
u~ .Ii
C) :::!jl
ffi ~I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
; Clearwater
u~
'"
co
oc
:g,g
:::l c:
.::ow
III
c: '"
O~
Uv>
{ .... z
'" 0
....
....
0 t-
L;: U
] w
0 tf)
<3
tf)
(f)
0
a:::
u
1;
~
iil
"lJ
~
C
a..
'"
6 g
~.g
:::l c:
J:;w
'"
c: .,
Q;t:'
UlJ)
....
.,
~
....
U1
"lJ
'"
>
o
a..
1 ~
Iw
>
lu
a:::
I~
I~
tf)
10..
~ ~
~
I
I
,
100
S .\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT _PLAN\2009
FMP\2009 ylan_9 _1_2009 Jinaldocx
-
-
CITY Of
n
h
:..')
~
nt
~
o
-
[/l
61
[/l
;
~
OJ
9
;.>
~
()
:>':
S"
:::
'"
'>
'"
o
o
""
1'T1
t""
o
o
o
'"0
'T1t""
~;.>
~z
81~
~~
;;;;.>
I: al
1- ~
I", Z
8(-l
I"" ~
::!1;.>
~ z
;:rJ
o 0
() 0
x ""
-
-
-
2: 1 Slope or
Flatter
-
-
-
-
-
-
-
-
Disturbed Eorth
PLAN VIEW
2'
Min.
Disturbed Eorth
Edge of Chon nels. Ditches.
Swales. Rood Side Slopes,
Etc., Undisturbed
SECTION A-A
T.L.M.
_IV
IIE't 11.\11:
--
_.
-
-
~'Min"
t
TEMPORARY EROSION
CONTROL DIVERSION
BERM
-
-
1 Clf'2
-
-
~~
- ....
g~
Q.O
"C ~
;"~
.... -
= ~
:=~
~ ~
= ~
~ ......
(JQ ~
~ ~
a
~
=
......
~
-
~
=
I
City of Clearwater
Floodplain Management Plan
I
"
\
SEOIMENT BARRIER \
(STRAW BALE TYPE SHOWN)
\
SUPPLY WATER TO WASH
WHEELS IF NECESSAR, I
~ ~.J
==
c
-<
o
~
C
1oloi
>
-<
Cl..
o
z
i=
II)
)(
1oloi
DIVERSION RIDGE REQUIRED
WHERE GRADE EXCEEDS 2%
I
I
EXISTING PAVED
ROADWAY
I
FILTER FABRIC
SECTION A - A
SPILLWAY
NOTE:
USE SANDBAGS, STRAW BALES
OR OTHER APPROVED METHODS
TO CHANEUZE RUNOFF TO BASIN
AS REQUIRED.
/
I
I
I
I
~
O~
,-'--
I
FLOW
I
2"-3" COURSE
AGGREGATE
MIN. 6" THICK
I
I
DIVERSION RIDGE
I
50' HIN.
PLAN
I
NOTES:
1. THE ENTRANCE SHALL BE MAINTAINED IN A
CONDITION THAT WILL PREVENT TRACKING OR
FLOWING OF SEDIMENT ONTO PUBLIC
RIGHTS-OF-WAY. THIS MAY REQUIRE TOP
DRESSING, REPAIR AND/OR CLEAN OUT OF ANY
MEASURES USED TO TRAP SEDIMENT.
~ Clearwater
u~
2. WHEN NECESSARY, WHEELS SHALL BE CLEANED
PRIOR TO ENTRANCE ONTO PUBLIC RIGHT-OF WAY.
3. WHEN WASHING IS REQUIRED. IT SHALL BE DONE
ON AN AREA STABILIZED WITH CRUSHED STONE
THAT DRAINS INTO AN APPROVEO SEDIMENT TRAP
OR SEDIMENT BASIN.
I
REV. DAlE
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
TEMPORARY EROSION
CONTROL
DIVERSION BERM
I
DAlE
7 02
INDEX NQ.
I
DRA~ BY
M.C.
a-IECI<ED BY
B.G.
APP. DESIGNED BY
llESCRIP11ClN
20F'2
I
102
S :\ESM\Staff\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009_ finaLdocx
I
-
- -
CITY 0 f
c::-":)
h
$lo;:)
~
&
-
o
w
f/]
fI1
f/]
;
~
0>
9
>
3:
"
~
:;
:l
"
~
o
o
'D
I
"1
t""'
o
o
o
."
"1t""'
3:>
.,,-
r::;z
813:
'D>
loz
->
Ig; Cl
'Dm
I 3:
-m
IN Z
0'"
01
I'D ~
=<>
Sl Z
;;:r::;
o 0
" 0
" 'D
WlIES:
-------
1. SIngle row of Strawbol.. or SlIt Fence to be placed prior to the .tort of
rough grading.
2. MAINTENANCE: All _Ion ond sntrotlon control dllllie.. shall be cheeked
regularly, eapeclolly after each rainfall ond wDlbe e1eaned out and/or repaired
as req\llred. .-/
.r- LAKE
ADJACENT
HOME
Pl1I .oIlled .. ,_
or StnNbaIoa (~
PROPOSED
FOOTPRINT
OF HOME
ADJACENT
HOME
Ewnlt ...... ...
~ *'~--
fill WIdllI _ Mr
(UIlllIIly 16 feit)
.r- CI1Y STREET.-/
-
- --
- --
~
~
~~
~
~
STRA WBALE SILT BARRIER
~
"'11-1 SIt stop
~l
~ IlaclcIII
~h-~,.v
"""u'" .M."".... , ~
~DfD""j'~~i&I;I~
~ ~ ~
~~
~ ~ ~ ~ ~
~
~
PREASSEMBLED SILT FENCE
.....
CITY OF CLEARWATER. FLORIDA
PUBUC WORKS ADMINISTRATION
ENGINEERING
MIlIIMlU' SINGLE FAMILY HOME
0lIDBI1'f EROSION CONTROL DETAIL
lIlI TEMPORARY STRAWBALE
IW SEDIMENT BARRIER
I IF I
IIA.
.........
_.
- -
~~
- .....
g~
Q..O
~~
S"~
..... -
= ~
:=~
~ ~
= ~
~ ......
(J'Cl ~
~ .,
a
~
=
......
~
-
~
=
-
o
~
CJ:l
Ei1
CJ:l
~
~
'"
9
>
s::
()
;>::
S.
:l
"
'>
to.)
o
o
'-0
1
'T"l
t""'
o
o
o
."
'T"lt""'
s::>
::9z
gls::
~:z
~6
1 tTl
1'-0 s::
I;: ~
0""
:$1."
I:=; s:
6l z
6:N
o 0
() 0
:>< '-0
-
-
-
" Below Throdt Min.
2 Below Throat Max
PLAN VIEW
-
-
-
-
-
-
10' Min.
CROSS SECTION
Clean Out When Sediment
is 6' Below Throat.
Leave Out Block Temporarily,
Insert Tile With Wire Screen
And Grovel Filter.
Circular Shape is Not Essential - Vary Shope To Fit
Drainage Area And Terrain. Observe To Check Trap
Efficiency And Modify As Necessary To Insure
Satisfactory Trapping Of Sediment.
IllY.
MlI
---
-
-
-
T.L.M.
IH!lIlED ..,
CITY OF CLEARWATER. FLORIDA
ENGINEERING DEPARTMENT
"..
TEMPORARY SEDIMENT
TRAP AT STORM
DRAIN INLET
-
-
-
10 18 94
IIlEll Ja.
605
1 elF 1
-
-
~(1
- ....
o .....
o~
Q..O
~~
;"(1
.... -
= ~
~~
~ ~
= ~
~ .....
(J'C:l ~
~ ~
a
~
=
.....
~
-
~
=
-
-
-
-
r
n>
~
~
a
n>
"'"t
-
o
v.
CI:l
f;1
CI:l
;
CI:l
or
9
:>
3::
('")
'"
S'
::l
"
'<
N
o
o
v::>
I
'"'1
l'
o
o
o
'"t:I
'"'1l'
3:::>
::9z
813::
~~
-:>
I~ 0
IV::>~
I;: ~
8(-1
1\0 ~
::11:>
~z
o..N
o 0
('") 0
'" v::>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PLAN VIEW
8' Min.
'I
Water Level During Storm
Overflow Pipe
Sediment Trap
Earth Berm
Min. 2: 1 Slide Slope
Stabilized Slope
Splash Pad and/or Stabilization
Required if Pipe Empties into
Other Than Body of Water.
CROSS SECTION
CITY OF CLEARWATER, FLORIDA
ENGINEERING DEPARTMENT
MY. DA.
T.L.M.
-.,.
.,.
TEMPORARY EROSION
CONTROL SEDIMENT
BASIN
__ lIP.
10 17 94
~r
1 Clf'1
-
-
-
~(j
- ...
o .......
o~
Q..o
~~
;"(j
... -
= ~
~~
~ ~
= ~
~ .......
(JCl ~
~ ..,
a
~
=
.......
~
-
~
=
I
City of Clearwater
Floodplain Management Plan
I
I
SPACING OF POSTS
TO BE 6-10 FEET APART
I
I
I
BACKFILLED TRENCH
FOR ADDITIONAL STRENGTH
FILTER FABRIC MATERIAL CAN
BE ATTACHED TO A 6-INCH (MAX)
MESH WIRE SCREEN WHICH HAS
BEEN FASTENED TO THE POSTS
I
I
FILlER FABRIC
MAlERIAL SECURELY
FASlENEO TO THE
POSTS OR IF USED
THE WIRE MESH
I
ATTACHING TWO SILT FENCES
\
. . LIl- - - l.LU -
I
APPROXIMA lEL Y 8
INCHES OF FILlER
FABRIC MAlERIAL
MUST EXlEND INTO
A TRENCH AND BE
ANCHORED WITH
COMPACTED
BACKFILL MAlERIAL
tuIII-. ---' ",.. ---
PLACE THE END
POST OF THE
SECOND FENCE
INSIDE THE END
POST OF THE
FIRST FEN CE
I
RUNOFF
(" LI..r-"'---
ROTAlE BOTH
POSTS AT LEAST
180 DEGREES IN
A CLOCKWISE
DIRECTION TO
CREA lE A TIGHT
SEAL WITH THE
FABRIC MAlERIAL
I
I
DIRECTION OF RUNOFF WATERS
t
t
DRIVE BOTH
POSTS ABOUT 10
INCHES INTO THE
GROUND AND
BURY FLAP
I
IIill. --'" "", ,,-
I
DESCRlP1IlJ'l
ORA.... BY
BVO
QiECICEtl BY
B.G.
APP. DESIGNED BY
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
INSTALLING A FILTER
FABRIC SILT FENCE
I
REV. DAl<
DAlE
7 02
INDEX NO.
7
1 OF 3
I
~ tlearwater
U~
106
S:\ESM\StaftlAMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan_9 _1_2009 _final.docx
I
I
I
I
City of Clearwater
Floodplain Management Plan
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Clearwater
~
I
1. Set Stakes
2. Excavate a 4" x 4" Trench
Upscale Along The Line Of Stokes
0' Max.
-
3. Staple Filter Material To Stakes
And Extend It Into The Trench
4. Backfill And Compact The
Excavated Soil
Sheet Flow Installation
(Perspective View)
l:J
o
l:J
o
3' Max.
A
Points A Should Be Higher Than Point B
Drainage Installation
(Front Elevation)
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
INSTALLING A FILTER
FABRIC SILT FENCE
REV.
DAlE
7 0
INDEX NO.
7
201'3
DAlE
llEsaapnll'l
107
S :\ES M\Staft\AMcKinney\2009 _FLOODPLAIN_MAN AGEMENT ]LAN\2009
FMP\2009 -plan _9_ I _2009_ final.docx
I
City of Clearwater
Floodplain Management Plan
I
EXTRA STRENGTH
NEEDED WITHOUT
I
I
STEEL OR
WOOD POST
FLOW
:;...--
I
FLOW
-
I
FLOW
-
I
10' MAX. SPACING WITH
~RE SUPPORT FENCE
6 MAX SPACING WITHOUT
WIRE SUPPORT FENCE
I
I
STEEL OR
WOOD POST
36" HIGH MAX.
PONDING HT.
FILTER FABRIC
ATTACH SECUREL Y
TO UPSTREAM
SIDE OF POST
RUNOFF
PONDING HT.
I
12" MIN.
RUNOFF
T
12" MIN.
9" MAX.
(RECOMMENDED)
STORAGE HT.
T
I
I
I
STANDARD DETAIL
TRENCH WITH NAllVE BACKFILL
ALTERNATE DETAIL
TRENCH WITH GRAVEL
I
NOTES:
1. INSPECT AND REPAIR FENCE AFTER EACH STORM EVENT AND REMOVE SEDIMENT
WHEN NECESSARY.
2. REMOVED SEDIMENT SHALL BE DEPOSITED TO AN AREA THAT WILL NOT
CONTRIBUTE SEDIMENT OFF-SITE AND CAN BE PERMANENTLY STABILIZED.
3. SILT FENCE SHALL BE PLACED ON SLOPE CONTOURS TO MAXIMIZE PONDING
EFFICIENCY.
I
REV. DATE
DEsallPlIl>>l
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
INSTALLING A FlL llER
FABRIC SILT FENCE
DAlE
1 02
INDEX NO.
1
3OF3
I
-.
I
~(learwater
U~
108
S :\ES M\Staff\AMcKinney\2009 JLOODPLAIN _MAN AGEMENT _ PLAN\2009
FMP\2009 ylan _9_1_2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
~
A
~Jt
'fJ'"
w
:<:
5
>-
a::
...;:
a::
o
Il.
~
~
PLAN VIEW
ATTACH FILTER FABRIC
SECURELY TO 2"x 4" WOOD
FRAME. OVERLAPPING
FABRIC TO NEXT STAKE
TOP FRAME NECESSARY
FOR STABILITY
2"x 4" WOOD FRAME
4 SIDES OF 0.1.
PONDING HT.
-t
SECTION A-A
NOTES:
1. DROP INLET SEDIMENT BARRIERS ARE TO BE USED FOR SMALL. NEARLY LEVEL DRAINAGE AREAS.
(LESS THAN 5")
2. USE 2"x 4" WOOD OR EQUIVALENT METAL STAKES. (3 FT. MIN. LENGTH)
3. INSTALL 2"x 4" WOOD TOP FRAME TO INSURE STABILITY.
4. THE TOP OF THE FRAME (PONDING HEIGHT) MUST BE WELL BELOW THE GROUND ELEVATION
DOWNSLOPE TO PREVENT RUNOFF FROM BYPASSING THE INLET. A TEMPORARY DIKE MAY BE
NECESSARY ON THE DOWNSLOPE SIDE OF THE STRUCTURE.
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
TEMPORARY SEDIMENT rW2
BARRIER AT DROP INLET INDEX NO.
REV. DAn:
DRA'ltl BY
Novo
C>tEa<ED BY
8.G.
AP!>. DE51~ED BY
lOF2
DESCRlP1lCJl
~ Clearwater
u~
109
S\ESM\Staft\AMcKinney\2009 JLOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 -plan _9_1_2009 jinal.docx
I
City of Clearwater
Floodplain Management Plan
I
I
""
'......
"
"
........
~ "
" '....
................., .....
...., . "",
1.5jAX. "'......, '~~'~h1
~Lh<~,,>>, /,.<.'~-,<C<~I
I..r "'. ~,~...:-,~ ,/'>,/,$>.. .> . ..!j
I. I .....,..- "'""", ,/--~...~t,.' ----_.._~., ........!i I
I '............. .~~~..."' /",- -~<"''''>",,;;< ,,,""1 I I
II I -- -...,.... ........:-....~ ~--....... /1Ii '-'<~"Y ./",< -/ 1,/ 3' MIN.
""", .......~,~" ,,, - .-- ,4'::;;-.- ",'" -/ I I
~) '<~~~~;C/ ~i~
//'r:'f"/
GATHER EXCESS ~ I I :
FABRIC AT CORNERS II )
\\,
2" x 4" WOOD FRAME
1
I.
1
I
I
I
Isometric View
FABRIC ~I.f..(.!-.. '~~7::.~/
1:"/1 --.. I
~t>'i- -
;cl.' <t
______ iil ..... I
-------'..........-.<..I..T==f.
.J......~p.
..... ~
I
I
I
I
Elevation of Stoke and
Fabric Orientation
I
Specific ADDlication
This method of inlet protection is applicable where the inlet drains in a relatively flat area (slope no
greater than 5:11:) where the inlet sheet of overlandflows (not exceeding 1 c. f.s.) ore typical. The
method sholl not apply to inlets receiving concentrated flaws. such as in street ar highway medians.
1
REV.
DATE
IlEsalPllai
DRA"BY
Novo
QiECl<EI) BY
B.G.
OESICNED BY
CITY OF CLEARWATER. FlORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
TEMPORARY SEDIMENT
BARRIER AT DROP INLET
1
_.
20f'2
I
; tlearwater
u~
110
S :IESM\S taftlAMcKinney12009 _FLOODPLAIN_MAN AGEMENT ]LAN12009
FMPI2009 ylan _9 _1_2009 jinaLdocx
I
I
------- -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
5/8 IN. POI.. YPROPYlENE ROPE
1/4 IN. liE ROPE
DEP'Di ACCORDING TO NEED
1/4 IN. CHAIN
ALL SEAMS HEAT SEALED ~
(BLOW-UP OF' SHACKLE CONNEClION) .
TYPE I
GALVANIZED 124 SAFETY HOOK
18 (OR 22) 02. ~NYL COVERED NYLON
PVC SLOT-CONNECTOR
TOP LOAD UNE
5/16 VINYl COATED CABLE
fOLDS EVERY 6 FEET
STRESS BAND
5/16 IN. CHAIN
BALLAST Ie LOAD UNE
STRESS PLA lE
1YPE II
REV. DAlE
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
FLOAllNG TURBIDITY
BARRIERS
TYPE I D TYPE II
DAlE
CHECKED BY
B.C.
N'P. DESIGNED BY
INDEX NO.
DESCflPTlDN
llF2
~
o
earwater
(;~
III
S: \ESM\Staft\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 --plan _9_1_2009 _final.docx
REV. DA1E
DESCl'IP11O!1
ORA"" BY
VD
OlECKED BY
B G.
_. DESIGNED BY
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS AOfollNISTRATION
ENGINEERING
FLOATING TURBIDITY
BARRIER
E II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
TYPE III
22 OZ NYLON REINFORCED VINYL
124 SAFETY HOOK
5/16 VINYL COATING CABLE
(ON BOTH SIDES OF CURTAIN
TO REDUCE STRAIN)
NOTE: ANCHORING YdTH BUOYS.
AS SHOVtM. REMOVES AU.
~nCAL FORCES FROM THE
CURTAIN. HENCE, THE CURTAIN
WIU. NOT SINK FROM YdNO OR I
CURRENT LOADS. " ;-
MI;[; ./
ORIENTAl1ON WHEN INSTAIJ.EI)
(llDAL SllUAl10N - TYPE III)
AUTDMAllC FLASHING
ATTACH UNES/ U GHT (ON AT OUSl<-
TO SHAO<LE OFF AT DAWN) 100'
ON CENTER SHAU. BE
USED IN NAVIGABLE
1 CHANNELS ONLY
" ;-
.....
STANDARD CONTAINMENT
SYSTEMS UGHT BUOY
~ Clearwater
u~
112
S: IESM\Staft\AMcKinney\2009 JLOODPLAIN _MANAGEMENT _ PLAN\2009
FMP\2009 --plan _9_1_2009_ final.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
TYPICAL LA YOUlS
SlREAM5. PONDS. AND LAKES (PROlEClED AND NON-llDAL)
ANaiOR PT.
mEAN~
-+
STAKE OR ANCHOR
EVERY 100' (lYPICAL)
SHOREUNE
~ FILL AREA
· ntlS DISTANCE IS VARIABLE
SHORELINE
ANaiOR PT.
11DAL WATERS AND/OR HEAVY "'ND AND WAVE AC110N
.----
,.---
~ .JI'
EBB ~ flOOD
-
-
-
-
-
,.---
-
.,- ~
EXISTING
CAUSEWAY
-
-
SHORELINE ./
ANCHOR PT.
ANCHOR ,.
ANCHOR BUOY
BARRIER NO\aotENT
DUE TO llDAL aiANGE
~ FILL AREA
· ntlS DISTANCE IS VARIABlE
REV. DATE
ORA"'" BY
DESCRlPl10N
CHECKED BY
B. .
_. DESIGNED BY
~ Clearwater
u~
113
S :\ESM\StafflAMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 jllan_9 _]_2009 _final.docx
I
City of Clearwater
Floodplain Management Plan
I
I
Straw Bales Are To Be Placed 4 Inches
In The Soil. Tightly Abutting With No
Gap. Staked And Backfilled Around The
En tire Ou tside Perimeter.
I
~ B= ~
= = C)
~
0 0
----=:::::: A A
0 0
--:::
I
I
I
- 0 0
~ 0 0 ~-------
= = = = ==-----
~
I
I
I
PLAN VIEW
I
~L Stoked Strow Bale
I
! .r'~'
I
rf ~:;. ~
. .
S CTION
I
.~
. "':"
I
.'
A-A
This method of inlet protection is opplicable where the inlet drains a relatively flot area (slopes no
greater than 5%) where sheet or overland flows (not exceeding 0.5 cfs) are typical. The method
sholl nat apply to Inlets receiving concentrated flows. such as stree or highway medians.
I
REV. DAlE
DESCIlPlIDN
ORAfIN BY
M.C.
(ekED BY
.G
GltED BY
I
N'P.
I
~ Clearwater
u~
114
S\ESM\S taft\AMcKinney\2009 ]LOODPLAIN _MAN AGEMENT ]LAN\2009
FMP\2009 ylan_9 _1_ 2009 Jinal.docx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
x 2" Stoke
Staked and Entrenched
50 Ib (ap prax.) Strow Ba Ie
Compacted Soil to
Prevent
Loden
Properly Installed Strow Bale
(Cross- Section)
1. Excavate the Trench
~ .tlearwater
jj~
~~
Bales Must Be Tightly
Abutting With No Gaps
3. Backfill and Compact the
Excavated Soil
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
REV. DAl[
ORA" BY
Novo
CHECI<ED BY
B.G.
N'f'. DESIGNED BY
DESCRPl1DN
115
S :IESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMPI2009 ylan _9_ I _2009 Jinaldocx
City of Clearwater
Floodplain Management Plan
'Mr. R....torc.cI Staked ond T_
Sit r....,.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
J'MlN.
St,*-.I Oftd r...,n,,""d
Sit r_
~
~&L
."
'NI'
r
II
DOUBLE ROW STAKED SILT FENCE
lit\!. PAn
Q($CRPllCIM
~ ~Iearwater
u~
_.
116
S:\ESM\Staff\AMcKinney\2009 ]LOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_1_2009 _finaldocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
'"
~
~
:>
:>.
[",
~ '...
S'\(>
i%
d
9::'..:t3
'p'
~ i
:i
t:!.
a
~
~
)>>
I:>r-
....
~1i
r-ili
t"')
i
....
~~
~il' I
;:: ~
1f" ~.
1 ~
~
~
~
~
it!
~
~
~
r-
r
f:
"
!S
1+
~ /)
~---I
", i i
at ,'".
D:.~i~]~
h~~
9:it~~
~if:ic;
. ~ -
~,i
~
~
'"
l'
Ulii
:I=il
~~Ii~
ii......
bl!lfo
~i!ll
...,.''''~,Vl
~if~
~ 1'"
;;Jll'lllj
"t..~
l"u
:11!
II
1""
~ifi
~qn~"i'~~
}~iHi'lill;j
if;.!l~b...~,i
it"u~l,..C'lt
~lll"~i.J~I~!.
""'I hh i~
i:~;i!U~d
<;;ii~/l.ltiflp'
;l;g~ _if "l
lii'lil I~,'&i
ill't .,th
lltlt~bfl
'll"'i!hl~ii'
I<<h!'l.h
'~lll.~hll.ai
h'if..' [f
tl" 1--$1
. ~
;;~ T~ {)('(1in (O.tAlln,J
)>
'"
;
~
\l'
!'
..
~f~.~ U
.nh 'tll
"pil~ ~~
!Uli U
tli:i ~~
,8';;1" t!
l;!~i Ii
111;~ .!
ll~~ i
JI~!
;~~
~i' ~I"I: llj "'f-l~~- !i1tf ~i:
I Jl .... ,.a~ .~ft ~[.
u gl f ~ ::"1 ~;" n !oft:
U J!u g ~~~i Idn "'~t
!i ~tl~ ~ li!1 ' It;g~
., i.'f ~a"} ~ 1
i~ ;~~ l!lidi ~ .
~~ h~~' "~:: ill.S'
;;J! it;.i4'... B"i ll.. ~l
h l!'f r i~~ ;11
!~ ht' i ~ III
II ;l.~i i ~ . -l
i' -=\11' ~ i
~. ~-!,' '" ~ ~:r
1. il~ll J i it
l. ~~.!
~" ~
Ii'
11
~
1
".-1
+
)>
"
~
,
ita:
"'~
U
~~i '411Sl\i('"
~~I ~fUti~~
4f1 IIUi!~
U' hJ!f4
"'.... !!~!l~U
Iii ~:i~if;.
l! d,J,u ~
..ia ~::'h1i'i' ~
iflll i~l!l~:; ~
~h ~!b~;; ~
'1'1 '. -'.;;~S'_
~:;.~ ...
!. ~:..9. ",t
:l', UU't:l'
,. ~R .,,-l;~
II ?i:.i..__
b iii.d~
:to ~ i~ .
u
117
S :\ESM\Staft\AMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 -p1an_9 _1_2009 Jinaldocx
;@learwater
u~
118
S:\ESM\StafflAMcKinney\2009 _FLOODPLAIN_MANAGEMENT ]LAN\2009
FMP\2009 ylan _9_1_2009 Jinaldocx
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix G
Engineering Department's Stormwater Design Criteria
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
CITY OF CLEARWATER
DEPARTMENT OF PUBLIC WORKS
STORM DRAINAGE DESIGN CRITERIA
INTRODUCTION
This manual is a guide to assist Engineers in the design of stormwater systems in the City of
Clearwater. In general these standards are a combination of requirements set by the
Southwest Florida Water Management District, and requirements set by the City of
Clearwater, Public Works Department. This manual does not propose to itemize the
requirements of the Southwest Florida Water Management District, but to highlight and
detail the requirements of the City of Clearwater. Where design standards of applicable
regulatory agency's vary, the more restrictive or higher standard will apply. The Designer is
required to be familiar with the current design requirements of the Southwest Florida Water
Management District. The appropriate Southwest Florida Water Management District storm
water permit and other applicable regulatory agency permits will be required prior to any
final construction permit approval by the City of Clearwater.
The Designers attention is called to the City of Clearwater requirement that all development
and redevelopment will require provisions for storm water management. In particular,
redevelopment will be required to provide storm water management facilities in accordance
with the regulations herein.
For the purpose of administering these stormwater management regulations, redevelopment
is defined as the alteration of buildings, parking, or other landform features of a property
which necessitates the Community Development Code review process. Redevelopment of
property for which no stormwater management facilities exists will be required to provide
such facilities in accordance with the methodology contained herein, notwithstanding that
the circumstances of the redevelopment may not result in an increase of stormwater runoff.
L
o
~
119 S\ESM\StaftlAMcKinney\2009 JLOODPLAIN _MANAGEMENT ]LAN\2009
FMP\2009 --plan _9_] _2009 jinal.docx
Ponds, lakes and detention area (wet or dry)
1.00
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
STORMW ATER MANAGEMENT
DESIGN CRITERIA
1. GENERAL:
All construction shall comply with the City of Clearwater Contract Specifications and
Standards. All stormwater facility designs must be designed and certified by a Florida
Registered Engineer.
Record drawings shall be submitted and certified by a Florida Registered Engineer before
final acceptance of project.
Desil:w FreQuencv
(a) - 10 Year - storm systems, culverts
(b) - 25 Year - channels and detention areas with outfalls
(c) - 50 Year - detention areas without outfalls
(d) - I 00 Year - detention areas without outfalls which when capacity is exceeded
overflow onto private property
Runoff Coefficients:
Buildings, paved areas, and other impervious areas
0.95
Turfblock
0.45
Green or pervious areas
0.20
Design coefficients shall be obtained by using the above coefficients on a weighted run off
method for both pre-development and post-development.
2. STORM DRAINAGE:
Detention areas must be built before storm sewers are installed. Slopes shall not be steeper
than four to one (4 : 1) and shall be protected from erosion by sod.
Time of Concentration
Time of concentration to first inlet on a system shall be determined by using velocity of
runoff chart. (Chart attached). A minimum time of 15 minutes to first inlet shall be used.
- 120 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
3. STORM SEWERS. INLETS. AND STREET DESIGN PERTAINING TO
WATER FLOW
Unless specifically approved by the City Engineer, reinforced concrete pipe shall be used in
all easements and street rights-of- way. Minimum size shall be 15" diameter. Design
frequency - 10 year storm. Mannings Roughness coefficient for storm pipe:
(a) RCP
15" - 30" inclusive
36" - 48" "
54" - up
~
0.013
0.012
0.011
(b) CMP or Aluminum
Asphalt coated
0.023
0.018
(c) PVC Storm Drain Pipe
0.009
The slopes for culverts used as storm sewers shall produce a velocity within the following
limits:
Maximum
CMP 10 fp.s.
RCP 12 f.p.s.
Minimum
2 fp.s.
2 fp.s.
Standard hydraulic gradient elevation shall be minimum of 1.0 foot below throat of inlet or
manhole.
Minimum Culvert Size:
(a) - Pipe - 15"
(b) - Box Culvert - 3' x 3'
Maximum length of pipe without access structure:
(a) - (15" - 18") Pipe - 350 ft.
(b) - (24" - 36") Pipe - 400 ft.
(c) - (42" & cover & all box culverts) - 500 ft.
4. INLETS AND MANHOLES:
Vertical throat opening for inlets shall be 5".
Inlets and manholes will be designed so as not to have standing water when not functioning.
- 121 -
5" Throat
Grate Inlet *
(No Wing Type *
(Single Wing Type
(Double Wing Type
- 4 CFS
- 4 CFS
- 6 CFS
- 8 CFS
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
All inlets to have manhole lids in accordance with City standards.
Inlets are not to be placed in curb return.
Pipes are to be cut flush with inside wall of inlet.
Subdrain shall enter structure a minimum of one foot above invert and 2' 6" below top of
structure.
When pipe diameter exceeds 30", inlets shall not be used as junction boxes, limit 3 pipes per
inlet.
For design purposes inlet capacity should be assumed as follows:
* - Subject to City Engineer's approval only.
Standard inlet wings shall be a minimum of four feet in length as per City Standards.
5. STREET DESIGN:
Generally gutter water should not be carried for distances exceeding 600 feet.
Except as where impractical, channeling water across intersections will not be allowed.
Inlet Spacing
Normal Grades - .5% up to 2% - 600 ft.
Steep Grades - greater than 2% - 400 ft.
Where grades exceed 2%, a 6' wing will be required on the inlet. Grades less than 0.5% are
subject to City Engineer's approval only. A minimum of 0.5% grade shall be required for
asphalt drives and parking lots. Right-of-way shoulders shall be sodded three feet behind
curb and remainder, graded, seeded, and mulched. Mulch to be dry or green per F.D.a.T.
current standard.
6. HEADW ALLS:
All inlet and outlet pipes shall be provided with a headwall, mitred end section, or flared end
section. Headwalls shall be reinforced concrete. Pinned Sand/Cement bag structures built
- 122 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
in accordance with City of Clearwater specifications may be permitted only for temporary
use. All outlets shall have an appropriate apron to prevent erosion.
7. CHANNELS AND SWALES:
Roue:hness Coefficient - for a channel with maintained vegetation is .030 to .035.
Normal channel depth shall not be within 10% of critical depth. When velocities exceed
maximum allowable values energy dissipators shall be provided. Plans shall include
undeveloped areas, pre- development drainage, and pre-development discharge at key
design points such as channels, existing ponds, sloughs, etc. Also post- development
calculations for storm runoff and proper detention shall be determined.
Type of Soil
in Flow Line
Maximum Allowable
Velocity (f.p.s.)
Fine Sand
Sandy Loam
Silt Loam
Firm Loam
Fine Gravel
Stiff Clay
Coarse Gravel
Hardpan
1.5
1.8
2.0
2.5
2.5
3.8
4.0
6.0
Major channels (Q greater than 30 CFS) shall have a five foot bottom width. Drainage
swales normally will not be permitted along rear lot lines.
Swales shall be vegetated and designed for a 50 year storm.
8. STORM WATER DETENTION:
This policy is to insure that runoff will not be increased beyond its present state by
development. It is also intended to protect the quality of receiving waters in the City from
additional pollution resulting from new development. The design frequency shall be a 25
year storm based on rainfall intensity graph for the Clearwater area. The duration may be
obtained from the Rational method for areas up to 10 acres. Design variations may be
considered for areas less than one acre. The runoff coefficient differential DELTA C is
obtained by subtracting pre-development coefficient from post-development coefficient.
For projects greater than 10 acres, systems design must incorporate the U.S. Department of
Agriculture Soil Conservation Service Modified Unit Hydrograph, or equivalent as
- 123 -
City of Clearwater
Floodplain Management Plan
determined by the City Engineer, in conjunction with a SCS Type II Florida Modified
rainfall distribution curve.
In the case of redevelopment of land upon which no stormwater attenuation or water quality
feature exists, or upon which the existence of such features do not meet the standards
applicable at the time of redevelopment, the redeveloper will be required to provide facilities
in a manner similar to an original developer and in proportion to the extent to which the site
plan of the property is affected or disturbed by the redevelopment. In the methodology for
calculating stormflow from property undergoing redevelopment, the pre-development
volume of runoff will be calculated by the use of a Weighted Runoff Coefficient taken from
the following table:
PROPERTY DESCRIPTION* WEIGHTED COEFFICIENT OF RUNOFF**
Undergoing redevelopment and not
contributing to an existing flooding 1/2 Actual
problem ***
Undergoing redevelopment and
contributing to an existing flooding .20
problem
Undergoing redevelopment and
contributing to an existing flooding
problem for which an attenuating
stormwater manage-ment project is 1/2 Actual
under construction
* City Engineer shall be the determining authority of the Property Description
** In no case shall the coefficient be less than .20
** To be applied only to area of property undergoing alteration
*** Situation wherein property damage occurs in a 25 year - 24 hour storm
The City of Clearwater standards relative to the provision of water-quality features are, by
this reference, the same as the Southwest Florida Water Management District's, excepting
that where SWFWMD may rule that no water quality features are required, the City's
standard shall require the provision of treatment of 1/2 inch of rainfall as applied over the
entire area of a development project and 1/2 inch as applied over the portion of the site plan
undergoing alteration in the case of redevelopment.
- 124 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
t(Sec.)
.
The design hydrograph is an isosceles
triangle with a time of concentration
equal to one half of the duration.
Detention design shall incorporate
a minimum time of concentration of
one hour & a 25 year storm intensity.
The outfall shall be restricted to
accommodate the pre-development flow
with appropriate overflow facilities
for larger volumes. Detention ponds
will require 0.5' of freeboard.
Q ----------
~Q = ~CIA
Time of
Concentration
Duration
Volume of detention may be established by multiplying time of concentration times DELTA
Q providing the outlet control structure (weir, pipe, etc.) is designed to restrict other than
pre-development Q. An outfall design allowing less than the pre-developed Q to pass is
acceptable if storage is provided.
Discharge to Lake or Wetland
In situations where the pre-developed Q abuts a lake or wetland, the developer may store
additional runoff above that required for water quality treatment in the wetland subject
provided that the following conditions are met:
Wetland with positive outfall has the capacity to store
a 25 year design storm.
Wetland with no outfall has the capacity to store a 50
year design storm.
Wetland has sufficient capacity to absorb additional runoff.
All areas on or off site contributing to a wetland shall be included in the design. Runoff
discharging directly to the wetland shall be transmitted via grassed swales. Runoff from lots
abutting a wetland shall be collected in an interceptor swale designed to drain dry in less
than 24 hours.
The maximum design high water elevation of the wetland shall be one foot below the lowest
floor elevation around the wetland or one foot below the flow line of the nearest adjacent
road, whichever is lower. The design wetland elevation shall be determined by the inflow
and outflow hydro graph method.
- 125 -
- 126 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
The impact to the wetland system will be taken into consideration when reviewing these
applications. Those areas directly outfalling tidal salt water basins will be reviewed for
water quality impacts only.
Dry Detention Systems
Dry detention systems are those that under non storm conditions are dry, ie., has a grassed
bottom and side slopes that can be mowed. These systems shall be designed with no steeper
than 4: 1 side slopes, preferably no deeper than three feet deep and drain dry within 24 hours
or less. The side slopes and bottom shall be sodded. Drawdown may be accomplished by
the use of underdrain according to City specifications or by percolation if the soil conditions
permit. At least one soil boring showing soil profile and the seasonal high water table shall
be provided with the site plan. The soil boring shall be located at the center of the proposed
detention area.
Wet Detention Systems
Wet detention/retention systems are those that under non storm conditions are designed to
have a standing pool of water. The design shall be in accordance with City Details. All wet
systems shall incorporate a vegetated littoral shelf over 35% of the areal cover of the pond
under normal conditions. Drawdown may include an underdrain system, natural percolation
or slow bleed down system. Underground vaults are not allowed as water quality facilities
and are permitable for water quantity storage only as specifically allowed by the City
Engineer.
Detention Pond Walls
The use of vertical walls on the sides of detention ponds or side slopes steeper
than 4:1 are discouraged and will not be permitted except as may be specifically
approved due to reason of undue hardship to the developer. In no circumstance
will vertical walls on detention ponds be permitted adjacent to rights-of-ways,
along the boundaries of adjacent parcels of land, on more than two sides of a
detention pond, or any side of a pond serving only as a water quality facility.
9. SUBMITTALS
In addition to submitting complete plans and specifications, the Engineer shall also
submit the following:
A. - Drainage calculations or computations including hydro-graphs for any
detention areas, retention ponds, complete with cross sections.
B. - A scale map or plat showing each subdivision drainage basin, as an
aid for review of the proposed work. A minimum of 50 feet of
topographical survey shall be required adjacent to the perimeter of the
proposed site.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
C. - Profile of hydraulic gradient for storm pipe system.
D. - All pertinent information of adjoining properties affected by stormwater
from site such as finish floor elevations of buildings, streets, channel or
receiving waters to the final outfall. All adjacent property draining onto the
proposed site is to be shown on the site plan.
Before project is accepted by the Public Works Department, a Registered Engineer must
submit written verification that the project was constructed in accordance with approved
construction plans.
10. ATTACHMENTS:
Rainfall - Intensity/Duration - Clearwater. This Rainfall Intensity Graph shall be used
for 10, 25, and 50 year storms.
Velocitv of Runoff - for use in determining intensity for above grade runoff.
Drainae:e Desie:n Computations - suggested for working out drainage computations
showing required information for submittal to City of Clearwater for approval.
- 127 -
........
N
00
-
-
".-
".-
-E.2nct.!!2tt~ . Conc. Pod
. '- Bas," 4" M' Install 6" (Min.)
Side Slope In. Grovel Bedding
4: 1 (Typ.)
CROSS-SECTION
FOOT TYPE E INLET (Modified)
.& NOlES
1. Fasten skimmer with 4 stainless
steel bolts w/lead anchors
2. Seal 011 edges of skimmer at
contact points with structure with
waterproof caulking or approved
equal
Aluminum
Skimmer
Orifice
Concrete Pad
Under Skimmer
Design High Water Level
Top of Bank
6" Freeboard
Water Quantity
Water Quality
Water Level
-
-
-
-
.
o
I
in
4'-4"
.
<Xl
2 1/4"
3' 0"
.
'"
I
':..t
s"
.
<Xl
Grate
/t1I/'2OO1
Add.t nat.
REV.
DArr
DESalIPl10N
-
-
-
-
-
Outfall Pipe
15" Minimum
Eye Bolts Per
FOOT Index 201
Top of Bonk
A.c.
N'P.
-
I'
3'-4"
.
'"
"
lC) .
. I '"
'" <'l ~
" C ~
I' Xl c
~ g E
I ~ ~ '0
~ N ~ ~
TYPEE
Straight Bors 2" x 3/16"
Reticuline Bars 1-1/4" x 3/16"
Bonds 1-1/2" x 1/4"
Approx. Weight 215 Lbs.
Inlet Wall ~
Pipe
Orifice Opening
ORIFICE DETAIL
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
STORM SEWER
OUTFALL CONTROL
STRUCTURE
W ORIFICE
REDRA\lI'I BY
Novo
cArr
600
INDEX NO.
214
1 OF 1
CHwcr.
A~.BY
-
-
-
-
'I
'0
C
C
ro
-
110
0::+
0'<
C.O
"0.....
cuO
-. -
~ (1)
s:Q)
Q) ~
~ Q)
Q)r+
(C~
(1)
3
(1)
~
r+
"tJ
-
Q)
~
-
-
-
-
tv
\.0
-
-
-
-
-
-
Aluminum Skimmer
Concrete Pod
Under Skimmer
-
-
-
-
6" U.D.
.
o
'I
in
.
<Xl
4'-4"
I~
2 1/4" 2-1/4"
3JO"
.
<0
I
<t
a"
PLAN VIEW
Design High Water level
Top of Bonk
6" Freeboard Grote
Water Quootity
5-3/4"
Eye Bolts Per
FOOT Index 201
Water Quality
Weir
Aluminum Skimmer
Pond Bottom
----
CROSS-SECTION
FOOT TYPE E INLET (Modified)
Added nata
DESatPllON
-
-
-
-
'" 31_4*' "
~
"-
II) .
. I <0
<0 N "-
" 0 ..,
~ .. 0
J " (
0 ..
0 ...
I 0. 0
Vl CD "0 "0
<t N N c C
N 0 0
[Il [Il
TYPE E
Straight Bars 2" x 3/16"
Reticuline Bars 1-1/4" x 3/16"
Bands 1-1/2" x 1/4"
Approx. Weight 215 lbs.
&. NOTES
1. Fasten skimmer with 4 stainless
steel bolts w/lead anchors
2. Seal 011 edges of skimmer at
contact points with structure with
waterproof caulking or approved equal
REDRA" BY
Novo
CIIECl<EIlIlY
!.\.D.O.
NIP. DES1~. BY
~.c.
CITY OF CLEARWATER, FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
STORM SEWER
OUTFAll CONTROL
STRUCTURE
W UNDER DRAIN
D~1E
6 00
~DEx NO.
215
1 Of 1
-
-
-
"TIO
0::+
0'<
C.O
-0-'"
aro
-. -
~ (I)
3:0)
0) ~
~ 0)
O)r+
(Q~
(I)
3
(I)
~
r+
"'C
-
0)
~
w
o
-
-
Aluminum Skimmer
.
o
I
in
Slot Or
V-Notch
Concrete Pad
Under Skimmer
Design High Water Level
Top of Bank
6" Freeboard Grote
Water Quantity
Weir
Slot Or V-Notch
Aluminum Skimmer
Normal Water Level
,/
Pond Bottom..... ~ Basin
Side Slope
4: 1 (Typ.)
12"
24"
4'-4"
.
<0
2 1/4"
3'-0"
.
CD
I
~
~
8"
.
<0
Eye Bolts Per
FOOT Index 201
_ Top ~ Bonk
" 3'-4" 'I
.
CD
"-
It') .
. I <0
<0 l'l "-
"- @ "l
'i en 0
Cl (
0 ~
"" 0
0.. 0
Vl lD .., ..,
~ N l'l c: c:
l'l 0 0
lD lD
TYPE E
Straight Bars 2" x 3/16"
Reticuline Bars 1-1/4" x 3/16"
Bands 1-1/2" x 1/4"
Approx. Weight 215 Lbs.
Inlet Wall
Outfall Pipe
15" Minimum
&. NOlES
1. Fasten skimmer with 4- stainless
steel bolts w / lead anchors
2. Seal all edges of skimmer at
con tact points with structure with
waterproof caulking or approved equal
#4 Bars
C 12" Ctrs.
Install 6" (Min.)
Gravel Bedding
-
-
CROSS-SECTION
FDOT TYPE E INLET (Modified)
-
-
-
-
&. O1/llV/2D01
REV. DAlE
Addod notal
DESCRIPTION
-
-
-
-
A.c.
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
STORM SEWER
OUTFALL CONTROL
STRUCTURE
W SLOT OR V-NOTCH
REDRAIIN BY
NollO
CMEOCEO BY
M.D.Q.
APP. DESlll'lED BY
A.C.
DAlE
6 00
INDEX NO,
216
1 OF ,
-
-
-
-
-
"TIO
- -.
0....
0'<
0.0
"C....
iirO
-. -
~ ~
~~
~ C)
C)....
(Q~
CD
3
CD
~
....
."
-
C)
~
-
-
-
-
l..N
-
- -
- -
-
Outfall Structure I
DETENTION POND
N.T.S.
-
- --
- --
- -
Sand Grown Sod
Sand Filter Medium Per Section
902.13 F.D.O. T. Standard Specification
For Rood And Bridge Construction.
Uniformity Coefficient 1.5 Or Greater.
Effective Groin Size Of 0.20 To
0.55mm In Diameter. (T)plcal)
Line trench and cover aggregate
with unwoven filter fabric.
(Mlrafl 140-N or equal.)
6" P. V.C. Underdrain
A.S. T.M. D3034. &.
F 949 Or Equal
As Approved By
City Engineer.
I- 12' l 24'
Max. Max.
l
NOTES: 1) FOOT standard underdrain Is
acceptable Ytith 6" minimum pipe.
2) No ADS pipe shall be used for &.
underdraln on City projects.
SECTION A-A
N.T.S.
-I
SECTION 8-8
N.T.S.
12'
Max.
6" Underdraln
CITY or CLEARWATER, FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
&.
REV.
RIljf::' BY
5/03 Add _ DIg. AST\! II. B...... ai~~ BY
DAlE DESl3PTIDN APP. DESGHED BY
UNDERDRAIN DETAil FOR
DRY DETENTION AREAS
DAlE
300
tlDEX ND.
217
1 ($ ,
- -
"TIO
0;:+
0'<
0.0
"'C""'ft
ero
:;" CD
s:C)
C) ~
:::s C)
C)r+
(Q~
(I)
3
(I)
:::s
r+
'"tJ
-
C)
:::s
w
IV
Perimeter of aggregate
to be fully wrapped with
Non DegradIng Fiberous
Filter T)'pe Material as
Directed by Engineer.
Mlrafi 140 N or approved equal.
Filter aggregate for underdrains shall be as
specified in the FOOT Standard SDecificatlons.
Section 901 - Course A99reqate. and shall
be either 16 or 157. If 157 Is used. it must
be washed and screened to remove fines.
The aggregate may be stone. slag. or
crushed gravel.
"TIC")
- -.
Or+
0'<
0.0
"'C....
arC")
:i' CD
s:Q)
Q) ~
~ Q)
Q)r+
(Q~
(1)
3
(1)
~
r+
Overlap filter material lB-
across top of aggregate.
Backfill trench with select
pervious Moteriol.
""C
-
Q)
~
Unless otherwise noted.
underdrain pipe shall be B- min.
diameter PVC with perforations
down - See Technical Specifications
for details.
TYPICAL SUBDRAIN SECTION
NON-ROADWAY
REV. OAlE
IlESClllP1lON
REllRAWN BY
B.V.D.
CHU?i'Y
_. ~BY
CITY OF CLEARWATER. FLORIDA
PUBLIC WORKS ADMINISTRATION
ENGINEERING
UNDERDRAIN
DETAIL
NON-ROADWAY
OA
3 00
INDEX NO.
219
1lF 1
-------------------
-
- -
-
-
- --
- --
-
- -
- --
CROSS SECTION
LAKE/POND
N.T.S.
-
w
w
H.W.L.
H.W.L.
N.W.L.
11
6
15' -18'
LITTORAL SHELF
N.T.S.
REV. DAn:
IlESCRll'llCH
soo
1. Uttoral shelf and upland areas to
be vegetated per city requirements.
2. Outfall structure shall Incorporate
sub drain with Inverts no lower than
normal water elevation. Overflow
shall be set at high water elevation.
water elevation.
3. Length to width ratio of pond
shall be no greater than 3: 1.
4. Exceptions to this design may be
with approval of the city engineer,
on a case by case basis only.
CITY OF" CLEARWATER, F"LORIDA
PUBUC WORKS ADMINISTRATION
ENGINEERING
REDRAWN BV
8.\1.0.
a-lEClCEI) BV
M.D.a.
1oPP. DESGNEI) BV
R.JM.
wn DETENTION
RETENTION POND
-
-
"T1(")
0::+
0'<
0.0
-0"'"
er(")
:i. n;-
s:Q)
Q) ~
::1 Q)
Q)r+
(Q~
(I)
3
(I)
::1
r+
"'tJ
-
Q)
::1
- 134 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix H
Engineering Department's
Stormwater Management System Policy
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Updated August 17,2007
CITY OF CLEARWATER
ENGINEERING & PUBLIC SERVICES
STORMWATER MANAGEMENT SYSTEM POLICY
Guidance Manual
DECLARATION AND INTENT:
. The surfac~ water ofthe City of Clearwater is a natural resource and must be conserved and protected
to maintain It's scenic beauty, and to achieve the fUll beneficial use of the rl1110Urce for the citizens and
visitQrS otthe City. This manual is intended to provide a surface water policy for the development and
Implementation of plans, programs, projects, and rules relating to the City's surface water resource.
Thill docUm,.,t shall not cOIlstitute "standards" or "criteria"; rather this dOCUment is intended only to be
a reterence guide. Specific stormwaler drainage design shall contin.ue to be developed in accordance
with the City Design Criteria, codified by City ordinance. Speclflc goals, obJectives, and policies that
guide project implementation Ire clearly defined by the City's National Pollutant Discharge Elimination
System (NPOES) permit, the City Comprehensive Plan Drainage Policies (Goals No, 16 and 11), and
State Water Policy and Law.
POLICY GUiDELINES
It shall be the policy of the Engineering and Public Services Oepartmltnts that:
I. GENERAL SURFAce WATER. PROTECTION AND MANAGEMENT
The Englneerlng and Public Services Departments shall provide an effective stonnwater management
program tQmlnlmize advne Impacts on the City's natural systems, property, public health, safety and
welfare for the citizens of Clearwater. Inadequate management of stormwater increases stormwater
f1QWS and vtlocltles, contribute. to erotlon and sedimentation, overtaxes the carrying capacity of
str,ams and other conveyances, disrupt. the function. of naMal system., undermines floodplain
management and flood control effortt In downstream communities, reduce$. groundwater recharge,
thr.atens PUblic h.alth and safety, ancl Is th.prlmary.ouree of the pollutant load to CI.arwater's
natural coastal water resources, As a result, water quality is degraded and beneficial use of the
resource's lost.
. EffectIVe stormwatermanagement shall require Maintenance and Operation by the City of Clearwater of
drainage Infrastructure, consisting of City-owned land and land on which the City has an easement or
right-of-way, for purposes of maintaining water flow to prevent flooding.
. Engln.erlngand Public Services Departments surface water management programs shall protect,
preaerve and restore the quality. quantity and environmental values for existing and new water resource
drainage systems to the maximum extent practicable.
. EngIneering and Public Services Departments, stormwater management projects shall maintain, to the
maximum extent practicable, during and after construction, the prll-development stormwater
charaoteristlcs of the site; to reduce stream channel erosion, pollution, siltation, sedimentation, and
flooding: to reduce pollutant loading that dimInish beneficial usesi to reduce the 10lSI of freshwater by
encouraging stonnwater reuse, and to address stormwater management on a watershed basis. thereby
providing cost effective water quality and quantity solutions to specific watershed problems,
10fT
- 135 -
I
City of Clearwater
Floodplain Management Plan
I
Updated August 17, 20()7
I
I
. All operation and maintenance activiti" undertaken by Engineering and Public SeNlc~s Departments In
City Stormwater systems, all capital Improvement projects developed by Engineering and Public
S.rvlces Depa~ments, and private development projects which are re'(iawed in Engineering and Public
Service$ Oepal'tments within City StormY/ater systems shall conform to the requirements of State Water
Polley as required by the City NPDES MS4 Permit.
I
. All stormwater related maintenance and capital improvements shall conform to the specific goals,
objectives, and policies contained within the City Comprehensive Plan, with particu.lar aU-ention being
given to compliance with prescribed levels of Service which have been established to determine the
availability of facility capacity and demand created by new or redeveloped projects.
I
I
. E:ffectlve stormwater management shall require maintenance and operatlon of drainage Infrastructure
.dedlcateu to the City of Clearwater for purposes of maintaining flow to prevent flooding.
. Wtlen determining the impact on surface water resources of the City, in the development of all
stol1l1Water related projects by Engineering and Public Services Departments, staff shall consider the
impact of thefaeilltle. on water quality, flShand wildlife, environmentally sensitive lands, reasonable-
beneficial uses of water, recreation, nevlgation, saltwater or pollution Intrusion, andfactol'$ related to
erosion and Sedlmentatlon, public health, safety, and welfare to minimize adverse Impacts.
I
. Stormwater facility project developmentahlll encourage interagency cooperation and alternate funding
sources for Implementation whenever feaSible.
I
n. $TORMWATER MANAGeMENT IMPLEMENTATION
I
I
The Engineering and Public Servlct$ Departments shall fully develop stormwater programs end capital
improvement projects with implementation sucCe$$ In mind. Inappropriate implementation of stormwater
management programs and projects, and the management of project construction, monitoring, reporting and
related permit or agreement conditions can lead to Ineffective and costly project delays or impesedpenalties.
. The cOnstruction and operation of City ttotmwaterfacilitles which manage or store surface waters, Of
other '<itlllt!es wh leh drain, divert, Impound, discharge Into, or otherwise impact waten In the State, and
the improvements served by such facilities, shall be consistent with all Stat. and regional permitting
requirements.
. All stormwater facilities and related Improvements must provide. adequate proviSion to avoid Increased
damage to off.site properties, water resources, natural systems or the pUblic caused by:
I
I
I
. All $Iormwater faelllties project development shall meet applicable design or performanQe standards,
with particular attention being given to whether adequate provlslonsexlstfor the continued satisfactory
operation and maintenance of the planned facllltles after construction has been completed.
(1)
(2)
(3)
(4)
(5)
(6)
floodplain development, encroachment or other alteration;
retarding, accelerating or diversting of flowing water;
reduced natural attenuation;
lack of adequate maintenance acces.;
facility failure; or
other actions that could adverselyaffeet off-$Ite water flows or levels.
I
I
. All stormwater facility repairs shall be performed in a manner that does not exacerbate existing
storm water problems.
I
2017
I
- 136 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Updated August 17,2007
. ErosIon and sedIment control plans detalllng appropriate methods to retaIn sediment on-site shall be
required for all land disturbIng activIties. Sediment control plans shall be fully Implemented and
maintained during construction.
. Where conflicts may reasonably be expected to exist between public and private stormwater facilities
during commercial site plan review, resolution of those conflicts shall be resolved by the Capital
Improvements Stormwater Management Committee (CISMC).
. There shall be a Capital Improvements Stormwater Management Committee that shall meet at least
quarterly and is to be made up of at le..t two representatives from Environmental Stormwater
Management, (ESM) and Public Services. The purpose of this Committee Is to consider significant
operational Issues, address polley changes needed to facilitate stormwater management for the City
and to establish capital project recommendations annually, by January. each year.
. Stormw..ter .ystem management In Clearwater shall be categorized as either Stormwater Maintenance
orStormwater Capital Improvements. Stormwater Maintenance shall be funded as a Uneltem while
Stormwater CapItal Improvements shall be funded as discrete projects based on annual prioritization
through the annual watershed management planning and evaluatlon process, subject to
recommendation by the Capital Improvements Stormwater Management Committee
annually,Admlnlstratlon of the Stormwater System shall be facilitated by a geographic information
system database that shall be created and maintained by Engineering with direct input by Public
Services.
. A rainfall, water quality, and flow monitoring network shall be instaUed and maintained by Engineering
for the purpo$es of model calibration, monitoring system response, and permit program compliance
(NPOES & Tampa Bay Estuary Program).
. Engineering shall maintain a current and calibrated hydrologicJhydraulic model for the monitoring of
existing conditions and the evaluation of proposed altemative solution. to stormwater problem..
Ill.
STORMWATER MAINTENANCE
The establishment of these maintenance policies for Public Services is critical to the overall effectiveness of
unit operation and accountability, and will serve as a guide to meeting the compliance requirements of NPDES
to further enhance the present MS4 system operation and maintenance programs.
. NPDES Permit Compliance: Procedures for maintenance of roadway. and stormwater runoff shall
operate in compliance with NPOES, MS4 Permitting.
. Stormwater Ponds: lake/Pond maintenance shall be re.trlcted to City owned systems or those portIons
of systems owned by the City only, and shall be limited to only those controls needed to satisfy an
Immediate problem. system operation, or to comply with provisions of agreement to remove slit and/or
nuisance or exotlc plant species where all appropriate licenses, permits, or exemptions have IIl'$t been
obtained. The City shall not be responsible for maintenance of private lakes or ponds. All repair work
shall be recorded on appropriate forms.
. Conveyance Systems: Shall not be enlarged or enhanced from the existing condition without prior
approval from Engineerlng. Repaln and Installation of equivalent plpe(s) shall be limited to a maximum
of 200 feet In length and up to 24 Inches In maximum diameter, no deeper than 5 feet (SUb-drain and
storm pipes). Ditches, swales. and channel creeks shall be maintained within their original design
parameters through silt removal and ditch bank grading on a frequency of no less than once every fly.
years. Ditch cleaning and cutting shall occur twice a year. Stormwater pipe cleaning by machine such
as VactorNaccon and hand rods shall be on a regular basis.
30fT
- 137 -
City of Clearwater
Floodplain Management Plan
Updated August 17, 2007
. Inlets, Curbs and Gutters: Street sweeping operations shall cx:cur on all residential streets twice a year.
Some areas of the City may be addressed more frequently than others at the discretion of the Public
Senllees Director. Street sweeping all City main arterials shall cx:cur on a regular basis. Curbs and
gutters affected by stormwater construction shall be restored to "As-Suilt" conditions for lengths less
than 200 feet. Any pedestrian ramps affected by stormwater con.truetion are to meet the ADA
requirements for proper grade, slope, and landing. Design of inlets, catch basin boxes, and silt boxes
shall be within these established maintenance guidelines. Whenever possible, inlets and catch basins
shall not be Installed within sidewalks.
. Paved and Unpaved Streets: Maintenance and operational reporting shall be reported. as defined under
StormwaterManagement Implementation guidelines. Litter control shall be provided by Public Services
on only those streets that maintain an active "Adopt-A-Street" or an "Adopt-A- Pond" Program.
. Drainage Easements: Maintenance and operation of City lakes and streams rights-of-way and
easements and asscx:iated City stormwater facilities shall be the responsibility of Public Services.
. Citizen Support: Public Services shall be the point of first cOntact by citizen response requests to
Inve.,tlgate stormwater problems In Clearwater. Public Services shall record and respond to all citizen
requests for inspection of a problem within 48 hours of receipt (Attachment A). Response shall either
include a maintenance resolution or follow-up request in writing to ESM for further investigation as a
potential candidate to capital improvement.
I
I
I
I
I
I
I
I
I
. Stormwater Certification: All Engineering and Public Services Department employees working with I
stormwater and drainage shall be certified In sedimentation and erosion control. Furthermore, It shall
be a requirement that all Public Services stormwater personnel are "C" licensed and/or sedlmentatlon
erosion control certified stormwater technicians within two years of hire.
IV. STORMWATER CAPITAL IMPROVEMENTS I
The City Comprehensive Plan requires that stormwater management be Implemented in the most cost
effective and efficient manner possible. The City has developed a Watershed Management Action Plan I
Intendedj to prevent eXisting water te$Ource problems from becoming worse, to reduce existing flOOding
problems, to improve ex'lsting water quality, and to preserve or restor. the values of City natural ecosystems.
Therefore, all stormwater related problems that are not defined as Stormwater Maintenance shall be
considered as a Stormwater Capital Improvement and shall be prlorltlz.ed (Attachment B) and funded in I
accordance with the City Watershed Management Action Plan annually. This shall be accomplished upon
recommendation by the Capital Improvements Stormwater Management Committee and approved by the City
Engineer, Public Services Director, City Manager and City Commission.
. All projects received by ESM shall be evaluated and ranked according to the problem classlflcation
established by the City Watershed Management Action Plan and Included In the project database for
quarterly review by the Capltallmprovements Stormwater Management Committee. Category Code and
Watershed Basin shall be used to sort all projects provided to the Committee for their review and
approval.
. Implement project development and construction in accordance with Committee recommendations and
appropriate City approvals.
4of7
- 138 -
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
I
upaatoa June 1.'>1, I.\lUf
V. EMERGENCY PROVISIONS
I
There shall come from time to time, those situations which result from unforeseen circumstances that
shall require staff the flexibility to accommodate resolution of an immediate problem, Implementation
of any project relative to this section shall be recommended by the Capital Improvements Stormwater
Management CommIttee and approved by the City Engineer and Public Services Director whenever:
I
. The Florida Department of EnvIronmental Protection has declared a shoreline emergency,
consistent with Chapters 628-33,014 or 628-49.009.
I
. A project requires immediate action to protect life and property, prOVided that EITHER condition
exists:
I
_' The condition of any stormwater management system, dam, impoundment, reservoir,
appurtenant work, or works is so dangerous to the safety of life or property as hot to permit
time for the Issuance and enforcement of an order relative to maintenance or operation; OR
I
:;,::;. The condition of passing or Imminent floods that threaten the safety of any stormwater
management system, dam, impoundment, reservoir, appurtenant work, or works; AND
I
THE FOLLOWING GUIOELINES ARE ALSO TRUE:
. There are no operational changes appropriate or available to alleviate the emergency.
I
. The project will not result in the creation of any new lanQS or permanent structures that did not
exist before the emergency.
I
. Project construction Is minimized to only that Which Is absolutely necessary to prevent the
imminent collapse of a structure or improve circumstances that threaten human safety or life.
I
. An after-the.fact permit shall be required for all work completed that clearly, Is not temporary In
nature.
I
I
7f~6~
CityenginHf
'7-2~-o ~7
Date
I
~.
07/27/61
Date
I
Public Services Director
I
I
5 of 7
- 139 -
I
City of Clearwater
Floodplain Management Plan
Updated August 11, 2001
Attachment "A"
CITIZEN COMPLAINT I CONCERNS
PROJECT REVIEW PROCESS
1. Citizen calls in complaint/concern Go to 2.
~~ ~~M~~~~~_~,_.~~~~______V____~M'cv"V"~~~M_~"~'~'"
2. Call goes to Stormwater Maintenance, Go to 3.
562-4950, and data Is logged >~_._>--_._-----
_._- nm~M_~'
3. Stormwater Maintenance determines concern Is a maintenance Got04
Issue
"_~_______~'__.___~",_._~_.~~..c_,'_m....c_.~____w__m_.
4. Stormwater Maintenance resolves Issue with in-house staff Stop
<<..'W<<m__~__ mm________" "'_'MM~ """~'- .m__m"'<< u_...______________........._......__.........____...____._..""
5. Stormwater Maintenance determines concern Is not a Goto6
maintenance issue.
,""'..'''''''--.......-- ......--...-- ..._-_.~,_._..._-,-- n_________..
6. rn/issue and Inspection report Is submitted to ESM Go to 7
. -~ -->~~>-->>>-~~>~--~>~-
7. ESM Inspects site Go to 8 or 11
.> ->--- w_.______............_____.._____.......____.m..m.m....
8. Problem/concern/issue determined to require R&R solution Goto9
9. Develops contract Go to 10
<"""",.......... .......m................_ ...........................----............-.
10 Out to bid, give to Construction Stop
...____N_'_..__......._,v_____.w~~~_,~_.~~~.. .~._.~~~~~.~_......~..-,-~-~~~- .-,-.,
11 Problem/concern/Issue determined to require CIP $olutlon Go to 12
-,-"-"-~"~~~~~~
12 Hire consultant or being In.house design Go to 13
-~~~~ ,_~_"'~_~.m~_~_,_.,"_.__~
13 Review project, 30/60/90/100 % Go to 10
6 of7
- 140 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Updated August 17, 2007
Attachment "B"
Project Priority List from Engineering
7 of7
- 141 -
- 142 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix I
City of Clearwater Comprehensive Plan - 2008
Stormwater Management Element
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Stormwater Management Element
. The City of Clearwater will continue to monitor the stormwater management utility
fee rate structure and amend it as required to remain competitive and maintain
an adequate funding source to provide revenue for flood control, maintenance,
retrofitting, and treatment of stormwater. In addition to the hydraulic
improvements, this would improve the quality of stormwater discharging into
surface waters, and will complement the measures proposed in the Surface
Water Improvement and Management (SWIM) program and the Tampa Bay
Estuary Program to improve surface water quality standards.
· The City of Clearwater needs to take advantage of any alternative funding
opportunities that may become available from any State agency with regard to
watershed management and/or general stormwater improvements.
· The City of Clearwater needs to continue to reduce flooding problems and strive
for abatement of flood damage to houses and streets.
· The City of Clearwater needs to continue to coordinate stormwater management
improvement efforts with Pinellas County and other incorporated areas adjacent
to Clearwater City limits for both water quality and attenuation.
· The City of Clearwater needs to continue to maintain, correct deficiencies and
improve, where necessary, current levels of service. Maintenance and
improvement of the City stormwater management system must be recognized as
a service provided by the City on a regular and continuous basis.
· The City of Clearwater needs to continue to prepare stormwater management
plans which will identify and prioritize the implementation of programs to improve
and enhance stormwater quality and quantity.
· Natural and man-made wetlands need to be utilized for stormwater storage and
protected as natural resources. Wetlands provide a natural wildlife habitat and
groundwater recharge functions which are pivotal characteristics of the natural
and urbanized environment. Such features are firmly established within
Clearwater's quality of life values.
· The City of Clearwater must continue to obtain appropriate permits from all
environmental regulatory agencies prior to implementation of water resource
projects.
· The City of Clearwater needs to research and develop new methods that are
technically, environmentally, and economically viable of treating stormwater
runoff before final discharge to improve and enhance local surface waters.
- 143 -
Service
Stormwater Management
Facilities
Level of Service Standards
Design storm
10 - year storm frequency for all new street
development using the rational design method.
25 - year storm frequency with positive outfall for
major storm systems with basin time of intensities
controlling the duration. *
50 - year storm frequency when no outfall and
discharge is to street right-of-way.*
100 - year storm frequency when no outfall and
discharge is across private property.*
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
· Prospect Lake will continue to serve as a basin for stormwater attenuation and
water quality management, as well as enhancing the aesthetic beauty of the
downtown area.
· The City of Clearwater needs to continue to participate in the National Flood
Insurance Program's Community Rating System (NFIP/CRS). Clearwater has
been an active participant since 1990.
STORM WATER
D.3 GOAL - PROVIDE THE MOST COST EFFECTIVE AND EFFICIENT
PROVISION OF STORMWATER MANAGEMENT INCLUDING THE
IMPROVEMENT AND ENHANCEMENT OF STORMWATER QUALITY
DISCHARGING INTO LOCAL RECEIVING WATERS, AND PROVIDE
MAXIMUM PRACTICAL PROTECTION TO PERSONS, PROPERTY, AND THE
NATURAL ENVIRONMENT.
D.3.1 Objective - To maintain adequate levels of service for existing and future
populations through the year 2020.
Policies
0.3.1.1 The following level of service standards have been established for the City of Clearwater
and shall be used in determining the availability of facility capacity and the demand
created by new development and shall be applied to all new development, redevelopment,
and for all City facilities through 2020.
* Design standards for stormwater quality treatment/storage quantity shall
conform to the current SWFWMD requirement [Presently being the SCS Unit
Hydrograph design method, using the design storm frequency and a twenty-four (24)
hour duration for sites ten (10) acres or more, and the rational design method for
sites under ten (10) acres]. .
- 144 -
I
I
City of Clearwater
Floodplain Management Plan
I
D.3.2 Objective -The City of Clearwater shall continue to develop watershed
management plans which should seek to identify, evaluate and implement the
most cost effective and cost efficient programs for storm water management,
including stormwater quantity and quality. These plans should also address
any projects included in the Pinellas County Surface Water Management Plan
for the implementation of all stormwater management, as well as
recommended funding sources.
I
I
I
Policies
I
0.3 .2.1 Coordinate and cooperate with appropriate local, State, regional, and
Federal agencies implementing the Pinellas County and City of
Clearwater storm water management plans.
I
0.3.2.2 Continue to Provide a stormwater management system throughout the
City that will afford the most economically feasible protection to
residents and property.
I
0.3.2.3 All stormwater management improvements should seek to meet
applicable goals, guidelines, and regulations established to provide flood
protection and pollution abatement.
I
0.3.2.4 Participate in interlocal agreements to study and evaluate stormwater
quality and storm water runoff management issues consistent with the
National Pollutant Discharge Elimination System (NPOES).
I
0.3.2.5 Coordinate and cooperate with Southwest Florida Water Management
District policies and regulations.
I
0.3.2.6 Continue to require new development to detain water on site and control
quantity, quality, and rate of flow being released into the receiving
drainage systems.
I
D.3.3 Objective - Lower high water profiles during storm events, as necessary, to
reduce house flooding occurrences and to lessen the resulting adverse effects
on public health, the natural environment, public and private property.
I
Policies
I
0.3.3.1 Continue to provide a program of regular maintenance to the stormwater
management system to ensure maximum efficiency and performance.
Ensure that storm water management plans include measures to remove
trash, sedimentation and other debris which impede flow and incorporate
structural and non-structural measures to reduce or eliminate the discharge
of oil, grease, heavy metals, and other suspended particles into the
stormwater management systems.
I
I
I
- 145 -
I
I
City of Clearwater
Floodplain Management Plan
I
D.3.3.2 Natural and man-made wetlands shall be considered as a means to provide
storm water management wherever possible and shall be maintained for
hydrologic purposes. The efficiency of natural and man-made systems to
convey storm water runoff shall be protected through the provision of
routine water quality maintenance schedules overseen by city inspections.
I
I
D.3.3.3 Continue to provide multiple use facilities, such as recreational open space
uses, with open channel storm water management systems, when
appropriate.
I
D.3.3.4 Development and redevelopment activities shall comply with all
stormwater management design standards and criteria.
I
D.3.3.5 Structural Development shall be prohibited where it is determined that
such development will have an adverse impact on storm water storage
areas, increase flood prone areas, significantly increase rates of runoff, or
cause other unfavorable drainage conditions. Both man-made and natural
systems shall be treated on an equal basis as a sensitive preservation area;
no distinction shall be made between a natural system and a man-made or
man altered hydrologic system.
I
I
D.3.3.6 Limit development that will result in building(s) constructed within/or over
stormwater retention/detention ponds, streams or channels. All wetlands,
streams, channels, or other hydrologic features, whether wetlands, ponds
or bodies of water having intrinsic hydrologic, biologic and zoological
functions with no distinction made in regard to its status to whether it is
man-made or natural shall be considered for a Preservation Land Use Plan
classification to ensure protection from development.
I
I
I
D.3.3.7 Continue active participation and cooperation with the National Flood
Insurance Program and the Florida Emergency Management Agency for
the purpose of recognizing flood prone areas, and establishing abatement
programs that endeavor toward a reduction in damages and losses due to
flooding.
I
D.3.3.8 Continue the established requirement of a twenty-five foot setback from
the tops of a bank from all wetlands whether natural or man-made, and
require minimum finished floor elevations in areas adjacent to lakes, bays,
creeks, the Gulf of Mexico, Tampa Bay and Old Tampa Bay, and other
flood prone areas.
I
I
D.3.4 Objective Continue the implementation of the most cost effective and efficient
plan to reduce the occurrence of street flooding where safety issues and traffic
problems exist as prioritized and set forth in the Capital Improvement
Element, and listed in the stormwater management plans.
I
I
I
- 146 -
I
I
I
I
City of Clearwater
Floodplain Management Plan
I
Policies
I
0.3 04.1 Identify areas where inadequate storm water management easements exist,
and obtain proper access to storm water management channels, structures
and appurtenances for maintenance purposes.
I
0.304.2 Improve all street stormwater management systems where deficiencies
exist as articulated in the City's annual budget document.
I
D.3.5 Objective - Protect and enhance the quality of receiving waters by the use of
"Best Management Practices" in accordance with the adopted watershed
management plans.
I
Policies
I
0.3.5.1 The use of "best management practices" shall be required before, during,
and after construction activities to prevent water pollution resulting from
erosion and siltation.
I
0.3.5.2 Vegetated swales, sodding, and appropriate landscaping will be required as
components of the drainage system for natural filtration before final
discharge into receiving waters.
I
0.3.5.3 Monitor major storm water management outfalls and receIvmg water
bodies to identifY the quality of storm water runoff and the impact on
receiving bodies.
I
0.3.504 Maximize water recharge potential in designing stormwater management
improvements by utilizing natural wetland areas for storm water storage.
I
0.3.5.5 Coordinate stormwater management improvements with other local
governments to assist in solving storm water management problems of an
extraterritorial nature.
I
I
0.3.5.6 Continue to identifY impaired bodies of water and prioritize them for
improvement and enhancement.
I
0.3.5.7 Water resource projects shall be consistent with the policies of the
Conservation Element and with adopted watershed management plans.
I
0.3.5.8 All stormwater management plan projects of the City of Clearwater shall
comply with the Florida Surface Water Improvement and Management
(SWIM) program and the National Estuary Program.
I
0.3.5.9 The City of Clearwater shall continue to upgrade and retrofit City-owned
drainage system facilities and include stormwater treatment for water
quality in accordance with the proposed storm water management plan.
I
- 147 -
I
0.3.7.3 The City of Clearwater shall pursue a system of regional stormwater
management which is both economically and environmentally sound.
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
D.3.6 Objective - Continue to provide sound fiscal management of the storm water
management systems to include maintenance, operation, and construction in
accordance with the watershed management plans and concurrent with its
implementation.
Policies
0.3.6.1 Operation and maintenance of the stormwater management systems may
be financed through revenues from the City's storm water utility fee.
D.3.7 Objective - Provide economic development incentives that promote water
resource protection and enhancement.
Policies
0.3.7.1 Methods of financing stormwater management system improvements and
new stormwater infrastructure construction should be evaluated to
determine the most feasible and equitable arrangement, both city-wide and
in local problem areas.
0.3.7.2 The City of Clearwater shall continue to seek and be on notice of financial
support for system improvements through grant programs administered by
appropriate State and Federal agencies.
Policies
I
I
I
I
D.4
GOAL - STORMW A TER DISCHARGE SHALL BE MANAGED TO PROVIDE
FLOOD PROTECTION FOR THE CITIZENS OF THE CITY OF CLEARWATER
AND TO PRESERVE, PROTECT, AND ENHANCE THE WATER QUALITY OF
RECEIVING WATERBODIES.
D.4.1 Objective - The protection, restoration, and enhancement of water quality
associated with stormwater runoff will be considered a function of the City's
overall stormwater management plans.
0.4.1.1 The City shall incorporate water quality protection and enhancement
criteria into the City storm water management plans.
0.4.1.2 The use of natural alternatives, the conservation of natural stormwater
management systems, and the protection and improvement of the quality
of receiving waters shall be a goal of the City's stormwater management
plans.
I
I
- 148 -
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
D.4.1.3 Management plans shall continue to be developed on an ongoing basis for
waterbodies with known or suspected water quality problems in the City to
include Tampa Bay, Clearwater Harbor, Stevenson Creek, Allen's Creek,
and Alligator Creek.
D.4.1.4 The City shall systematically and timely prepare watershed or waterbody
specific management plans, and update them as necessary for waterbodies
within the City. Such plans shall include both water quality and flood
control considerations and recommended funding sources.
I
I
I
I
I
I
D.4.1.5 The City shall implement all City-approved watershed management plans.
D.4.1.6 All City storm water management plan projects within watersheds of +the
City shall comply with applicable SWFWMD, State, and Federal
requirements, includin~SWIM Plans for that waterbody or watershed.
D.4.1.7 The City shall continue to coordinate with and supplement the County's
surface water monitoring program.
I
I
I
I
I
I
I
I
- 149 -
- 150 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix J
Application for Non-Substantial Damage/Improvement Review
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
~ Clearwater
Development and Neighborhood Services Department
100 S. Myrtle Avenue, Suite 210
Clearwater, FL 33756
Telephone: (727) 562-4567 Fax: (727) 562-4576
www.myclearwater.com
u
APPLICATION FOR
NON-SUBSTANTIAL DAMAGE I IMPROVEMENT REVIEW
Parcel Number:
Property Address:
Owner's Name:
Co-Owner's Name:
Owner's Mailing Address:
Owner Phone Number:
FIRM
Panel:
Flood Zone:
BFE:
Lowest Floor Elevation (excluding
garage):
I am attaching an appraisal report of my property, or
I am not submitting an appraisal report of my property
I accept the County's Estimated Market Value.
Initials
Initials
Initials
I accept the attached estimated cost of construction as a fair cost of repair or improvement for my home.
Initials
SIGNATURES:
Owner:
Date:
Co-Owner:
Date:
Contractor:
Date:
- 151 -
City of Clearwater
Floodplain Management Plan
~ 'Iarwater
Development & Neighborhood Services Department
100 S. Myrtle Avenue, Suite 210
u
Clearwater, FL 33756
Telephone: (727) 562-4567 Fax: (727) 562-4576
www.myclearwater.com
SUBSTANTIAL IMPROVEMENT/DAMAGE
NOTICE TO PROPERTY OWNERS
'~re you rebuilding your home after a storm?"
'~re you making an addition, renovating or remodeling your home?
Here is information YOU need to know about the 50% Rule.
If your home or business is below the 1 DO-year flood elevation, Clearwater has flood damage
prevention regulations that may affect how you remodel, renovate, or add on to your building. If your
home or business sustained structural and or interior damage, these regulations may affect how you
rebuild. These laws are required by the National Flood Insurance Program to protect your lives and
investment from future flood damages. Your community must adopt and enforce these laws in order
for federally-backed flood insurance to be made available to community residents and property
owners.
Inform yourself and save time, aggravation, and money. Please read the following information.
Substantial Damage means damage of the origin sustained by a structure whereby the cost of
restoring the structure to its before damaged condition would equal or exceed 50 percent of the
market value or replacement cost of the structure before the damage occurred. (Note: the cost of the repairs
must include all costs necessary to fully repair the structure to its before-damage condition.)
Substantial Improvement means any reconstruction, rehabilitation, addition, or other improvement of
a structure, the cost of which equals or exceeds 50 percent of the market value of the structure before
the "start of construction" of the improvement.
If a building is "substantially damaged" or "substantially improved", it must be brought into compliance
with Clearwater's flood damage prevention regulations, including elevating the building to or above
the 1 DO-year flood elevation.
Clearwater, following National Flood Insurance Program requirements, has the responsibility to
determine "substantial damage" and "substantial improvement" and has implemented the following
procedure to do so:
- 152 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
1. Development & Neighborhood Services will estimate Market Value by using the tax
assessment value of your structure (excluding the land).
If you disagree with this estimate of Market Value, you may hire a state licensed appraiser
and submit a comparable property appraisal for the depreciated value of the structure.
2. You must submit to Development & Neighborhood Services a detailed and complete cost
estimate for the addition, remodeling, reconstruction, or repair of all damages sustained by
your home, prepared and signed by a licensed general contractor. The contractor and you
must sign separate reconstruction or improvement affidavits indicating that the costs
estimate submitted includes all damages or all improvements to your home, not just
structural.
Development & Neighborhood Services will evaluate the cost of improvements or repairs
and determine if they are fair and reasonable. For damage repairs, pre-storm prices and
rates will be utilized. The cost of improvements or repairs does not include items not
considered a permanent part of the structure. (i.e., Plans, surveys, permits, sidewalks, pools, screens,
gazebos, fences, etc.) (See attached copy.)
3. If your home is in the designated flood zone, then an Elevation Certificate must be
submitted to determine the lowest flood elevation. Garages and carports are not
considered the "lowest floor".
4. Substantially damaged or substantially improved structures with the lowest floor below the
1 DO-year flood elevations are required to be elevated to or above that level. Likewise, all
electrical and mechanical equipment (heating and cooling, etc.), bathrooms, and laundry
rooms must be elevated to or above the 1 DO-year flood level. Only parking, building
access, and limited, incidental storage is allowed below the flood level. Non-residential
buildings may be "flood-proofed" instead of being elevated.
If the lowest floor, electrical and mechanical, equipment, laundry and bathroom are already
above the 1 DO-year flood elevation, the building can be repaired and reconstructed without
further modifications.
5. Building plans must be prepared to show how the building is to be elevated. These plans
must be prepared and certified by a registered professional engineer or architect.
6. Following a Presidential disaster declaration, the Small Business Administration may make
loans available for both homes and businesses for purposes of elevating the structure to or
above the 1 DO-year flood elevation. Proof of "substantial damage" from Clearwater
Development & Neighborhood Services is required.
- 153 -
City of Clearwater
Floodplain Management Plan
ITEMS TO BE INCLUDED
All structural elements including:
./ Spread or continuous foundation footings and pilings
./ Monolithic or other types of concrete slabs
./ Bearing walls, tie beams and trusses
./ Wood or reinforced concrete decking or roofing
./ Floors and ceilings
./ Attached decks and porches
./ Interior partition walls
./ Exterior wall finishes (e.g., brick, stucco, or siding) including painting and decorative
moldings.
./ Windows and doors
./ Re-shingling or re-tiling a roof
./ Hardware
All interior finish elements, including:
./ Tiling, linoleum, stone, or carpet over sub-flooring
./ Bathroom tiling and fixtures
./ Wall finishes, e.g., drywall, painting, stucco, plaster, paneling, marble, or other decorative
finishes.
./ Kitchen, utility, and bathroom cabinets
./ Built-in bookcases, cabinets, and furniture
./ Hardware
All utility and service equipment, including:
./ HV AC equipment
./ Repair or reconstruction of plumbing and electrical services
./ Light fixtures and ceiling fans
./ Security systems
./ Built-in kitchen appliances
./ Central vacuum system
./ Water filtration, conditioning or re-circulation systems
ALSO:
./ Labor and other costs associated with demolishing, removing or altering building
components
./ Overhead and profit
- 154 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
ITEMS TO BE EXCLUDED
Plans and specifications
Survey costs
Permit fees
Debris removal (e.g., removal of debris from building or lot, dumpster rental, transport fees
to landfill and landfill tipping fees), and "clean-up" (Le., dirt and mud removal, building dry
out, etc.).
Items not considered real property such as: throw rugs (carpeting over finished floors),
furniture, refrigerators, stove not built-in, etc.
Outside improvements, including:
Landscaping
Sidewalks
Fences
Yard lights
Swimming pools
Screened pool enclosures
Sheds
Gazebos
Detached structures (including garages)
Landscaping irrigation systems
ITEMS REQUIRED TO DETERMINE SUBSTANTIAL DAMAGE:
The following must be included in the application submittal (please keep a copy for your files)
1. Completed application
2. Detailed cost of improvement/reconstruction estimate and affidavit, signed by a general
contractor
and a copy of his license certificate.
3. Elevation certificate
4. Current photos, or photos before and after the storm (if available)
5. Existing floor plan drawing (if available)
6. Owner's reconstruction improvement affidavit signed and dated.
7. Contractor's reconstruction improvement affidavit signed and dated.
- 155 -
City of Clearwater
Floodplain Management Plan
~ ~learwater
Development & Neighborhood Services Department
100 S. Myrtle Avenue, Suite 210
u
Clearwater, FL 33756
Telephone: (727) 562-4567 Fax: (727) 562-4576
www.myclearwater.com
GUIDELINES TO COMPLETE
THE RECONSTRUCTION IMPROVEMENT COST ESTIMATE FORM (attached)
Reconstruction/Repair = Percentage of item that must be repaired or reconstructed.
(Example: A house has 20 windows, only 10 were damaged and being replaced; ratio should equal 50%)
ITEMS
RECON/REPAIR OFFICIAL
COST USE
RATIO OF WORK
LABOR +
MATERIALS
Concrete, Form, ETC $4,500.00 40%
Carpentry Material (r) $9,004.00 100%
DoorslWindows, Shutters $2,046.00 50%
- 156 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
~ ~.arwater
Development & Neighborhood Services Department
100 S. Myrtle Avenue, Suite 210
u
Clearwater, FL 33756
Telephone: (727) 562-4567 Fax: (727) 562-4576
www.myclearwater.com
ARCHITECT/ENGINEER
RECONSTRUCTION/IMPROVEMENT AFFIDAVIT
Parcel #: / / /
Property
Address:
Arch itect
Name:
Address:
/
/
License #:
Phone:
I have reviewed the contractor's list of work to be done with the plans prepared by my office. The list
accurately reflects the scope of work indicated on my plans and specifications. The proposed
estimated cost is in line with current average industry standards for the work reflected in my plans and
specifications.
See Attached Itemized List
Total Labor and Materials $
Overhead & Profit $
Total $
AFFIDAVIT
STATE OF FLORIDA
COUNTY OF PINELLAS
PERSONALLY APPEARED before me, the undersigned authority,
- 157 -
SWORN TO AND SUBSCRIBED before me this
A.D.
day of
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
who, being duly sworn, deposes and says that he/she has read, understands, and agrees to comply
with all of the aforementioned conditions.
Architect/Engineer's Signature
Date
Notary Public-State of
Florida
Commission Expiration Date
- 158 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
~ Clekrwater
Development & Neighborhood Services Department
100 S. Myrtle Avenue, Suite 210
U Clearwater, FL 33756
Telephone: (727) 562-4567 Fax: (727) 562-4576
www.myclearwater.com
ESTIMATED COST OF RECONSTRUCTION/IMPROVEMENT
Parcel
#
/
/
/
/
/
Property
Address:
This Cost Estimate of Reconstruction/Improvement must be prepared and signed by a licensed General Contractor
COST
ITEMS LABOR + MATERIALS
COMMENTS
Concrete Form ETC
Caroentrv Material (rouah)
Caroentrv labor (rouah)
Roofina
Insulation & Weather Stria
Exterior Finish (stucco)
Doors Windows & Shutters
Lumber Finish
Caroenter labor (finish)
Hardware ltinish)
Hardware (rouah)
Cabinets (built-in)
Floor coverina (tilelrua)
Plumbina
ShowerlTublToilet
Electrical
Liaht Fixtures
Built-in Aooliances
HVAC
Paint
- 159 -
City of Clearwater
Floodplain Management Plan
Demolition and Removal
Overhead and Profit
TOTAL
Contractor Name:
(PLEASE ATTACH ANY ADDITIONAL INFORMATION)
Address:
Siqnature:
- 160 -
Contractor Lic. #:
Phone #:
Date:
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
~ Cl~arwater
Development & Neighborhood Services Department
100 S. Myrtle Avenue, Suite 210
u
Clearwater, FL 33756
Telephone: (727) 562-4567 Fax: (727) 562-4576
www.myclearwater.com
CONTRACTOR
RECONSTRUCTION/IMPROVEMENT AFFIDAVIT
Parcel #:
/
/
/
/
/
Property
Address:
Contractor
Name:
License #:
Address:
Phone:
I attest that I, or a member of my staff, personally inspected the above-described property and
produced the attached itemized list of repairs, reconstruction and/or remodeling. This list is submitted
for a Substantial Damage or Improvement Review. These damages/improvements are ALL OF THE
DAMAGES /IMPROVEMENTS sustained by this structure, and that all additions, improvements or
repairs proposed on the subject building are included in this estimate.
I understand that I am subject to enforcement and penalties if an inspection of the property reveals
that I have made repairs or improvements NOT INCLUDED ON THE ATTACHED LIST. This includes
any non-conforming or illegal structures/additions, or repairs made to the existing structure without
having presented plans for such work. I understand that any permit issued by the City of Clearwater
pursuant to this affidavit does not authorize the reconstruction, repair or maintenance of any illegal
additions, fences, sheds, or non-conforming uses or structures on the subject property.
(See Attached Itemized List)
Total Labor and Materials $
Overhead & Profit $
Total $
AFFIDAVIT
STATE OF FLORIDA
COUNTY OF PINELLAS
Before me this day personally appean::~rl
- 161 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
who, being duly sworn, deposes and says that he/she has read, understands, and agrees to comply
with all of the aforementioned conditions.
Date:
Contractor's Signature
SWORN TO AND SUBSCRIBED before
me this
day of
Florida
Notary Public-State of
Date
Commission Expiration
- 162 -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
~ Clearwater
Development & Neighborhood Services Department
100 S. Myrtle Avenue, Suite 210
u
Clearwater, FL 33756
Telephone: (727) 562-4567 Fax: (727) 562-4576
www.myclearwater.com
OWNER
RECONSTRUCTION/IMPROVEMENT AFFIDAVIT
Parcel #:
/
/
/
/
/
Property
Address:
Contractor Name:
License #:
Address:
Phone:
I attest that I, or a member of my staff, personally inspected the above-mentioned property and
produced the attached itemized list of repairs, reconstruction and/or remodeling. This list is submitted
for a Substantial Damage or Improvement Review. These damages/improvements are ALL OF THE
DAMAGES /IMPROVEMENTS sustained by this structure, and that all additions, improvements or
repairs proposed on the subject building are included in this estimate.
I understand that I am subject to enforcement and penalties if an inspection of the property reveals
that I have made repairs or improvements NOT INCLUDED ON THE ATTACHED LIST. This includes
any non-conforming or illegal structures/additions, or repairs made to the existing structure without
having presented plans for such work. I understand that any permit issued by the City of Clearwater
pursuant to this affidavit does not authorize the reconstruction, repair or maintenance of any illegal
additions, fences, sheds, or non-conforming uses or structures on the subject property.
(See Attached Itemized List)
Total Labor and Materials $
Overhead & Profit $
Total $
AFFIDAVIT
STATE OF FLORIDA
COUNTY OF PINELLAS
Before me this day personally appeared
who, being duly sworn, deposes and says that he/she has read, understands, and agrees to comply
with all of the aforementioned conditions.
- 163 -
City of Clearwater
Floodplain Management Plan
Owner's Signature
Co-Owner's Signature
SWORN TO AND SUBSCRIBED before
me this
Florida
Date
- 164 -
day of
Date:
Notary Public-State of
Commission Expiration
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
Appendix K
Capital Improvement Stormwater Utility Project List
- 165 -
City of Clearwater
Floodplain Management Plan
Item 10 yr 25yr 100 yr TOTAL
KIO PM Class Status WS Location PROBLEM COST STATUS
# Structure Structure Structure est.
Begin design
of phase I
Tropic Hills Drainage 4/07, FDOT
PV F-1 PI in D CZ2 Improvement Project Property & Street Flooding. $5,600,000 implementing
(Burma) phase II,
Phase 3 in out
ears
2 ES F-1 P ALC Property & Street Flooding. $100,000 On hold
(regrading)
Remove 8 structures/ 17 dwelling 100% Design
3 MM F-1 3 11 18 D STC units from 100yr flood $3,800,000 ( Construction
1 0-07)
(School board
property not
available,
4 ES F-1 2 3 20 P STC Remove 21 structures/ 21 dwelling $1,760,000 scope will be
units from 100yrflood reduced and
design will
begin in 07,
Const 08
- 166 -
-------------------
- - - - - - - - - - - - - - - - - - -
City of Clearwater
Floodplain Management Plan
Design in 07,
Remove 5 structures from 100yr construction
5 MM F-1 1 2 6 0 STC $3,800,000 begin in 08
flood and complete
in 09
Remove 4 structures from the Project 10,
6 ES F-1 1 4 P STC 100yrflood $850,000 add inlets on
Bermuda
7 ES F-1 0 0 2 P STC Remove 2 structres from the 100yr $850,000 Project 50
flood
8
ES
F-1
o
2
2
o
AGC
9
1
EC
F-1
o
1
P
AGC
- 167 -
Remove 5 structures from 100yr
flood. Improve LOS at Old $7,000,000
Coachman Road.
Phase II
Improvements,
design
complete in
07,
construction
begin in 08
and complete
by 09
Remove 1 structure from the 100 yr
flood. Improve LOS at NE
Coachman Road.
Must be
replaced
$1,680,000 before
channel F
im rovements
City of Clearwater
Floodplain Management Plan
10 EC F-2 0 0 0 D AGC Improve LOS at Old Coachman Rd. $1,999,000
11 ES F-1 0 2 41 P STC Remove 42 structures from 100yr $2,530,000 Project 4A
flood
Major storm pipe failure imminent
12 RJM F-1 P STC and present system is undersized $1,200,00 Tak
and under homes.
13 RJM F-2 P ALC 415 North Duncan Undersized pipe with major street $126,000 Collection
flooding. System
14 RJM F-2 P AGC Marilyn St., off N.E. Insufficient storm sewer system
Coachman
15 RJM F-2 P 1729 Jade Ave Water backed up for years
16 RJM F-2 P Rainbow/Mars Street Undersized pipe with major street
Flooding flooding.
Byram Pond Dredging
& Expansion - Spring
17 ES E-1 P STC Branch Stabilization Water Quality / Maintenance $831,636
Union St to Byram
Pond
18 ES E-1 P STC Upper Stevensons Erosion $1.415,843
Creek Stabilization
Betty Lane Forested Verify needs
20 ES WQ-1 P STC Habitat Preservation Water Quality $1,100,000 to be
Site Removed
100% Design
Mandalay Outfall Beach pump station removed & (Advanced
21 ES 0-1 P BCH Improvements new box culvert outfall $500,000 Engineering)
construction
on hold
- 168 -
-------------------
-------------------
City of Clearwater
Floodplain Management Plan
22 0-1 P BCH Storm Lift Station Beach pump station needs retrofit $880,000
Rehab-Kippling Plaza
23 PV 0-1 STC Transfer Yard Upgrade FDEP Compliance issue $326,000
26 EC WQ-1 AGC Alligator Lake Complince with FDEP consent $874,000
order
28 EC WQ-1 AGC Alligator Lake Compliance with FDEP consent $874,000
order
Stevenson Creek
29 ES F-1 STC Watershed Update with improvements and 10 5250,000
Management Plan new or revised projects
Update
I Alligator Creek
I 30 EC F-2 AGC Watershed Update with improvements and 10 $250,000
[ Management Plan new or revised projects
Update
Ditch was
31 ES STC St Thomas to Bellevue 950' of failing CMP closed in and
piped
RJM R&R box repair
!- 1551 Jeffords 3015
5 RJM R&R box repair
IA 1015 Tuscawilla St 1075-1065
RJlv1 R&R box repair
, Causeway & East Shore (seditment need to be remove from Bay)
i- RJM R&R barnacles
5
- 169 -
City of Clearwater
Floodplain Management Plan
1-4 Papaya & East Shore 3070 (seditment need to be remove from Bay)
RJM R&R barnacles
1-4 2986 Fernham Dr Asset #71 05
RJM R&R repair through liner
1- RJM Downing St. (3155&3161) Storm pipein easmtbetweenhomes Replace pipe between houses pipe relocate to front of property.
5 R&R
I- . t~m,J~t Thomas pipe replacement
5 RJM R&R
1- St. .4056 pipe replacement
5
1- ._, lane Asset#8090 pipe replacement
5 RJM R&R
1- .1000 Lakeview Asset #1 090 to #1065 pipe replacement
5 RJM R&R
1- Drew StlCoachman to Nash (United MethodistChurch) 200' CMP pipe replacement
3 RJM R&R
I. WPC
5 RJM R&R seawall/headwall
1- RJM Bay Cove seawall/headwall
5 R&R
RJM Progress Energy ROW .7005 liner
5 R&R
1- RJM R&R 2076 Ridge Ln CMP
5
1- RJM R&R AGC Landmark Dr. North of Green Meadow Ct. PipeJaHure
4
1- RJM R&R 3353 lake Shore Lane 24" into 30" RCP
4
- 170 -
-------------------
-------------------
City of Clearwater
Floodplain Management Plan
1- RJM R&R 2632 Brandy Wine Dr 18" RCP
4
1- RJM R&R 2951 Meadow HillDr Sinkhole at box, 18" RCP
4
- 171 -
City of Clearwater
Floodplain Management Plan
Priority
F-1 IStucture Flooding
F-2/Street Flooding
Discuss these for removal from the CIP List
C-1 IRegulatory Compliance
r
o
j
e
2007
2008
0-1/0ther
2009
F-3/Bridge Flooding
E-1/Major Erosion
2010
WQ-1 I Water Quality
2011
R&R 07(ongoing)
and/or
Completed Projects
Infrastructure - 1 - New
Infrasturcture - 2 - Fair
Infrasturcture - 3 -Average
Infrasturcture - 4 - Bad
Infrasturcture- 5 - Failure
-172-
-------------------
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
City of Clearwater
Floodplain Management Plan
END OF REPORT
- 173 -
City of Clea,rwater Floodplain Management Plan 2009
~
'\j Q)
L.;::b
01
jj'
,I ~
~o
'I .
Gulf
of
Mexico
OLDSMAR
01 :~
. -jU
''TTI
II'
" .1, I
"
DUNEDIN,
'<,
'\
o
--
'>
I P", 'Dc?' ~ -
I ~. c, '"
~! ~,..l:, ')
rill:]) P' ~ G
at r'" 'l'.~,f' ;-,.. ""-; D
a.</ l.)
.
'c..~., Q 0
~)
!,
I: rT.1
II
II'
'J
:t P
BELLE~IR I
"'I;
LARGO
..." 9
I
~c5 ~
-.:
~
N
w-<?- E
S
Scale: N.T.S.
Clearwater Service Area
vs
Clearwater Landmass
Including SFHA
Comparison
Figure: 1
Date: 5/19/2009
Source: Clearwater Eng. Dept./ May 2009
Legend
D Clearwater Service Area (Municipal Boundary)
34398 Acres Total
~ FEMA SFHA (Total SFHA coverage based
on 2007 FEMA reporting)
6126 Acres Total
:" '..: Clearwater Landmass (The Land-Only portion
... .
of the Clearwater
Service Area)
20640 Acres Total
Land-Only FEMA SFHA (The Land-Only
portion of the SFHA)
3487 Acres Total
IL C~ Prepared by:
o Engineering Department
>- .learwater Geographic Technology Division
I- ~. , 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
----
--- - --
City of Clearwater Floodplain Management Plan 2009
I
;-f
I. JI.~
l I~ .
'\: ;,
, ,
. .
. .
.. .
. ,
. ,
Ii:;:
,1,
.' .
. .
. '.
:',.,
I.: ".
. .
.J;,. 'f""
If"" .
..:-," .
i'" ,.
" -"'.
'.. ~ I
I.... C..< .
'. .
.,,,,, ., i' ". .'.
. Jd I' ....
. . . ....
. UJ . I r. .'
.':S: . ....
: q:~: : ::~~~
. ).. . . I....
: ,,5 : :_,::~:~ ~
,)",'9:. . (J) I' ~. .
: ~(~: \t;. ~~ ~~ ~
'f ~. .' I' I' .
: ~..: ~ .;. ~.;
. :'JUR' . ,',-Ill' .--
:[?~ .,: ::"~_.::~~'.
./lt.....} :~ ~.-...
BAYMOJJT t.~ '.....~..... .....
. ~-. "".. . .. .
: /""l: ...:;- \ ~.. ~ ~ I, : 't
:t ": tj.:..-~::~::::~
:~ '., ...... <, ::~l: :::::
_:~ -: ~.'.,' L.....~...
. ill d.... .....:...]' :'1.,.,1,',:
:/0', ......:..:::::::
'~,.::o ~'..... I, I, ... I, .
::'~::."..'.' ":'4,~.11l'~:
.lb...... ,-,=1,0
;yfC).......:~ ~"'~
\:t~.~ .::;:::-.....: ~.~,~<' C'
~'. "",~dl~ ...... ..:..~~
/ ", ~:~......._.... ...:"
J "~':. J':;. - .-' ..f
"'r..... ..........
I, ....
.... II ".
.. '.. ~"
, ~ .
. .
.... \ ..- ~
.. ~l ~<:;)' ...
: >~"...
: -uS Y,:
.. (j ...
. .
. .
. .'
. ,
, .
. .
, .
... ..
: !(:
. /,.
. I ,
. ,/.
: /;':
. .
. ,', .
.. 1/ .'
. .
. ,
. .'
.. H.....
..:.I..~......:.
. '. .... ., '.
jf~..:....{:
{
_ ~URLEWRD, :.....;....~~.~~~{IL..:....Un2:':'......
. ~ .
III .
_ ~ III? LAKE T~RPON z
. liJ,} lud[ C . 'Z'
I: _\ ,0 'ANAL
. I :'foRrl!,~/DE [ . .
~ I: C..D/? - 11/,1/ ..:
~ CURLEW; CliE~Kj -:~> z~ 0 o~, / ; L,
= uj ::::0> ~I":~~ ~I( ~ ......:...:
~ -"co I:~~ _ lc- ~ ..':1';;
';:' l
~
\.
\
/
(
.
~
Clearwater
Harbor
DIRECT RUNOFF
TO GULF
\\
I
II
I\OJ
I,')>
,v<
l'Ul
1\0
'1m
\IOJ
\~
\,0
"Gl
\Im
\\
N
w-<?- E
s
Seale: N.T.S.
./
"
\'
,I
\1
Southwest Florida
Water Management
District (SWFWMD)
Drainage Basins
Figure 2
Date: 4/17/2009
SWFWMD I June 2002
Source: Parsons Enaineerina I Dee 2000
Legend
Drainage Basin
_ ALLEN CREEK
_ ALLIGATOR CREEK
BELLEAIR GOLFCLUB RUN
BISHOP CREEK
_ DIRECT RUNOFF TO GULF
DIRECT RUNOFF TO BAY
_ CURLEW CREEK
_ JERRY BRANCH
_ LAKE TARPON CANAL
_ LONG BAYOU
_ MULLET CREEK
STEVENSON CREEK
r::.: Clearwater Landmass
Outside Clearwater City Limits
IL c- Prepared by:
0, Engineering Department
Geographic Technology Division
~~ learnrater 100 S, Myrtle Ave, Clearwater, FL33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is fumished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient with the
understanding that the data received was co/iected for the purpose of
developing a graphic infrastructure inventory, As such. the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
~
H'
Ii
i\
)J~.
gD[J~i
I}JOOru.l~i~
J1tilOI . ~
].~1O ~..\I
~~~ {i~\\1
COASTAL !~~b ~\~\
BASIN BEACH S~~! ~~~
BAYMoIT3Ej ~~
i ~U/j ~'~l\'\ r
)&~)tf,ll.11
ql~.'.. ..~.~/tAnJ
~~\C.~~
'~~~.)
i' .._~
~ '~.., . Clearwater
\~.....
COASTAL \.....Q.J Harbor
; 'C" l
BASIN BEACH ~ -0"~'/.:.~
J0 .jl'
,~'
/;'1'
., , 1Jf
I"
/i
/.I;;~
J,.l!ir;';i
~!f.'1
Gulf
of
Mexico
CURLEW RD.
s.",
'r. 58.,
OLDSMAR
MICHIGAN BLVD
g
n::
~
(J
~
~
DUNEDIN
@
f-
C/)
~
ijj
2:
ii:
SOLON AVE
o
:::i
/..:
-.J
"
SAN CHRISTOPHER DR
51.
~~~
VIRGINIA
ST.
'"
'"
I()
~
OJ
~
1Jl
o
m
OJ
~
o
Gl
m
N
W~E
!!ARGO
s
Seale: N.T.S.
SWFWMD Drainage
Basins within
Clearwater
Figure 3
Date: 4/17/2009
SWFWMD I June 2002
Source: Parsons Enaineerina I Dee 2000
Leaend
[] Drainage Basins within Clearwater
D Ponds, Lakes, Rivers, Creeks
r::.: Clearwater Landmass
Outside Clearwater City Limits
lL - Prepared by:
o({:l t Engineering Department
Geographic Technology Division
~ . ..earnra er 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory, As such, the City of Clearwater
makes no wa"anties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
Gulf
of
Mexico
OLDSJYlAR
DUNEDIN
'.
SAFETYjHARBOR
BELLEAIR
N
w-<?- E
s
Scale: N.T.S.
Clearwater Zoning
Boundaries and
Drainage Basins
Figure 4
Date: 4/17/2009
Sou ree: Clearwater Planning Dept I June 2008
Legend
[J Drainage Basins within Clearwater
Clearwater Zoning Districts
D LOR - LOW DENSITY RESIDENTIAL
D LMDR - LOW MEDIUM DENSITY RESIDENTIAL
D MDR - MEDIUM DENSITY RESIDENTIAL
. MHDR - MEDIUM HIGH DENSITY RESIDENTIAL
. HDR - HIGH DENSITY RESIDENTIAL
~ MHP - MOBILE HOME PARK
. C - COMMERCIAL
. T - TOURIST
. 0 - DOWNTOWN
D 0 - OFFICE
. 1- INSTITUTIONAL
. IRT - INDUSTRIAL, RESEARCH, TECHNOLOGY
D OSR - OPEN SPACE, RECREATION
. P - PRESERVATION
r::.: Clearwater Landmass
Outside Clearwater City Limits
11. C:7"t..} Prepared by:
01 11 '\ Engineering Department
Geographic Technology Division
~~ . ~ar\V'ater 1005. Myrtle Ave. Clearwater, FL33756
U~ Ph: (727)562-4750, Fax: (727)526-4755
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department, and must be eccepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory, As such, the City of Clearwater
makes no W81T8nties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
assodated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009:
Gulf
of
Mexico
OLDSMAR
DUNEDINj,
~
i: I
SAFETYfHARBOR
Clearwater
Harbor
BELLEf,\IR
N
w-<r'
s
LARGO
III
Scale: N.T.S.
Pinellas County Future
Land Use Boundaries
and Drainage Basins
Figure 5
Date: 4/17/2009
Source: Pinellas Planning Council/ Jun 2007
Legend
C Drainage Basins within Clearwater
Residential and Mixed Use
. RE - RESIDENTIAL ESTATE
. RS - RESIDENTIAL SUBURBAN
. RL - RESIDENTIAL LOW
L RU - RESIDENTIAL URBAN
. RLM - RESIDENTIAL LOW MEDIUM
. RM - RESIDENTIAL MEDIUM
. RH - RESIDENTIAL HIGH
. RlOL- RESIDENTIAUOFFICE LIMITED
RlOG- RESIDENTIAUOFFICE GENERAL
. RlO/R- RESIDENTIAUOFFICE/RETAIL
. RFH- RESORT FACILITIES HIGH
. CN - COMMERCIAL NEIGHBORHOOD
CL - COMMERCIAL LIMITED
. CG - COMMERCIAL GENERAL
. CBD - CENTRAL BUSINESS DISTRICT
IL - INDUSTRIAL LIMITED
. IG - INDUSTRIAL GENERAL
. P - PRESERVATION
. RlOS - RECREATION/OPEN SPACE
. INS - INSTITUTIONAL
~ T/U - TRANSPORTATION/UTILITY
. CRD-COMMUNITY REDEVELOPMENT DISTRICT
r::.: Clearwater Landmass
Outside Clearwater City Limits
II. - Prepared by:
oCI t Engineering Department
Geographic Technology Division
~~, ~arwa er 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)6624760, Fax: (727)6264766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient with the
understanding that the data received was colieeted for the purpose of
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
compieteness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Ciearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
-....... .. -=r:f1rftij' tL<ul~~ ~..c .!kC'!r:EWRD, __) ~~:,~ . I jj I
~I . l"~ '\'~., ..-..EIi:l....1y' ti
MiJIIG ~'/ ", .- 'l~\' '",. - -
*~,2~~-!J ~t~))~-~f ,~Hs'"E --- ~I'I~ ~~ 1~4.J.. ~.~ :;501"\
'J C>.\../CJJ..I' 18 ffi ~ · I?I ~ i\ ',.~
!r2.1 ~~}~ ?' << P\ ~ r.- ..)1 ~ . '" ~ o~, '~ ~ ~ ~ ~ ~ 0 ~
o:rM~. ~1(c?1~() '~,...--?= } l.i 111 lil, 4 .J..,t~ ~ .:...~'\~.; :'~ '~
"iN tJy<!cL.' ~J r '1~4 J I, 'lI) ~ \;
D ~lJZf ;:1,1 · , lQ. illl SOLO AIi~ '.:::J ~
'il 'w, .~ -, ,... ~ '., \t\ "
~ ~ ,{ r~,,F;JTO:;;':'~- · :~~~_~__u mu ~ V :&.\~,) ~),"
~r_1 CV~t<Ir ~ · · . s~'" . ~ / ~:.,.
, · 2';.'~ !o.!\', ' '='l ~~cou."":o. ~ . :~..Il{/<.-'-l!1
I~.... ',. . i~ 3/~/A Q 'tf. 1J, I ~<P. 0 hltG' WOOD ~1 H :e, ~,_ ~,i.
~ ~ '~l~ ~~ _ ~ IT . ~. ~,ENTERPRISE RD, :!!-.. ~ . L'" "IJill r.,. ; J"
~. ~ L 0 ~ ~\"I} ~ \.
ll_u; ~ ~~e: i!:'1l _ ..~ .1'_. ~{~
~ ' ~~ I VIRGINIA G~'f;: : 0....: SAFT'ETY>HARBORo, ~~ --
cr 1 ~F 0 .", - .. ~.... - _.~ I
rr"-..J. ~ ~. 'Q rfA, ,LA.. Q -a-,a; ~ ............ ~ · ~ ---- f. ~ 0 ~ l1gj) ,,"':
g ~~, ; I - ~ ~ If ~'"!k~' ~ ~ ~ f l , ~~ . ~ ~ ,~. , ..
~ ~[L.,._...:;, ._.....~~.~. :~.s.Pl~ . ~ UNIONsr; , (~ %'--<I~' ~~,:,
l:! ~,~'~ c::::r'":. -{ ! ...l'>., '
I 'U /, r~ ~ ~~~14 ~ ~ )V ~ MONTCLAIR RD. ~ ~ (7"" 0 I,
g 8 '1, ~,'~.A'f: ~I! ~ ./ / ~ ~=- ~A/i.?T. ,~ "},
/Jj 'I]' ! . UNSET POINT RD, SUNSET POINT .~. 'JIll ............ r, I ""'" .Milor;
~ ~\ J~~",~ t~~r., ) ~ f3" :g . l.. -\~. J'>'~
""If, ~~. . p [~~~ "'J "b~ ~ I J"" ~ . d Jilrt'l'!'-?'
~11-~ n r~'.1l! ~ '? l2~ ~ ~ ~"~. ~.ik~.fIt lE .. SR.590 . -~ ',. 1;:..,.<:,~'
~ \))1 ~\~ ~J.Od:!o~.J v . ,~~ ~~~~ '.\ I,
~~ ~ h~l. ~\.~~. .Jo~~. _ "il... ~.
u ~,' ~PA'a, O~ ST. ?/jVJ1.EJ:T..Q ~ .~'-~~ . I~ . \. I ~ UJ ~'I\'
'f! rA'~~ ~.!!5 ~ '~f,rD ~.~.~.;\ ~..1~11 ' - \ )~:.
.;,{ . r ~- J"I : ~ ~iI"; -- '" - "'I~. '
~-", ,D1 p ST /~," -l u~ iJk~SI.( " ;1.pirJ1: ..t~"."';:"
1 ::"\~ J 'J L:E l!A 0 ST ,- ~ 411..... '-'" ~' ....:.@.'":'.
l 9 ~ 0 hll~~ ~,'" ,,' If'- ,:
~ ~ 0.... 0 -." 1 L ;-
. a! ~ '\. ll.l ..... ~ .~~'" f . . . . . . . '_
T. ~~... .. "-~'):r:(l ........,......-
it:' . CO Ii.. . GU TO BAY RI VD .te'''' Ail' con_~^' . . ';('''' ~ 4',,' ..... .
· .... i\ ~ ~ ~ .~ ~ '<~..-''-'!: If'
" .15, ~ rt: RD. .. "~Ir' ;y - (1\
~~,l..i'~ ~~ ~f~~~~ ~~~. I ~ ~~I: IV:;, ~I~ 'J,
,"ll."~ J ~I J~d" :S.r 10 .@ ~ 1~ ....-. ,1.1. 'Fe ~'" J!
· c 4':.... ~ fj" :.. '1'. 'A' ~ Ell: II R "'\~~ , ."11 ~ ~ ~ ~ J~'?/
~ s..: {:<I ~ l' ~ t , ' ~ ~ ~:\ ~ '7!)'- '~~~~l A~~~1 \t>.,~
AT Y':": rJ.:~~ }IJ ~ ! I ~ . i ~ I" ~ _ ~J ~~; ~ ... ~ ~rJ~r .EO :~
t!J? } ~ -.lE '~ -. (if' ~ ~ :x: -::. . . 'i"I . NURSERY ~11Qc:~ lJd~~~ ~~
~~.. "J7l~' : l ... ~~ ~ ( Q ~Ql.l: '11 ~CSfQ 1.j}iiit
j,:~B~LEA~...... i_~). :~;,.::;. ~r~- : l~d~R' rt~~ ~Q; ~. 'u' . """F 1"llJ"'.
- / .. ..-, -<tt~.~;~ .'I!.A~G0'1 ~ '~~"~ ~ (....." i@jl r:...., c;;,..;~~
" '!'!'i. ......." _. .1.____, ~,"""~ ,I!o;; ~~ ....Ii ~ '" ,,_ ."
rl
Gulf
of
Mexico
{~:
f.<.
r:7
~,~~
.;:~i ~,~'\.
.~). ~
f.l {];;'
.w' w ...,
~~
l!I;"~
. '\
i'l~rJ~
i:~J~Mi;
,f~~gQ~('. ., i \'
f,',: t lil. : '" ~
11 . " ~ ~,
':~ ~~}, - ~ ~\
I~~ ~., ~i ,~~..'~
:~~ I ~~,
I;~'t ,~~,~ -~? .,.
BAYM]~ ~o" .:~~
if;t 'J ~~T",\ ~~' '" .
~,~;, ~W.. .~.
~}" ~'" ..~%;'~~t,~l~li
~J R \1 "1
:~:-~ ~,of,.,".
.. , ~of,., .~
1=!J5t~~~ ~ o~
'_I "..~_ ~ '~~ '9('
h~, . ~ " O<p.
~~o."~fj' "", .
:..; . . ~,'"
.~ . ~,"-'
.~ ..~.. ~
....Jr~,. C/ea.water
~/~~.l;~~~.: Harbor
'. ~'i
, (~
tJ~.. .~
M~rl ~..
".' ~
.
t
A;-
I~
;<i
~~l
. ....
\~
~.,~
. :: 'fU
/I~'~~
.~~~~
. ~~.~
, :58
.. ~-
'~~
.~ .~
~~
Ul
~
lJ)
'5
m
Ul
;0
'5
Gl
m
N
w-<?- E
s
Scale: N.T.S.
Topographic Map
Figure 6
Date: 4/17/2009
Source: Pinellas County I May 2005
This Clearwater Topographic Map is a
representation only. Surface contours were
derived from airborne L1DAR data, and are
not equivilant to surveyed elevations.
LeQend
Contours
ELEVATION (ft)
~2
~4
~6
~8
~10
~15
~20
~25
~30
~35
'"'-' 40
'"'-' 45
~...~ 50
60
70
80
90
100
::::::::: Clearwater Landmass
Outside Clearwater City Limits
Il. - Prepared by:
o 'el t Engineering Department
. Geographic Technology Division
~ ea1'\\Ta er 100 S, Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department. and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory, As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use, Furthermore. the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
Gulf
of
Mexico
-f-,
, ~u
.\
~
\).
./.1
/jf1J
'/
~
~
~
~~.
~
~.
BA
~
~
'/ ,
~ '/
I
'<< ?
:; ,/'
7'
'i'
"/ .
II!) II J~)J ~ ~ ~_' L'; CURLEWRD] ~ 1'1 ;: .........~~.~e~)u\:S.o \\ /" _ _ . '"-0;,.Li1 r??;,"':;:-';);
~l -" r:O I ~ ~l _ J 1.1 ~( ::,11; I; -- :~il~ ~'n;~~j~-- ..:.......~.........~.... - ~~ ~ b~~"-~--.;::~~~~&~~ JCJ~[o'3[
tr t. I J II' [ -:.:::~~ II IL 1:_IG'~11 L" Q..l. tAKE ~tIIRPON ~ ~ ~~ ~
, if ~ I' I'i r ' . 1111 'ii P 'I ~ 1 to: D,~~ ,J --.;::
~?1 &--L~:?/~g,JmJ~ - '~I _- I IL~_JliJJ l~:_~;,\ ,'- I 'c CA~L - " 0 '8 ~ OLDS!VIAR /(~
nnrl7f1nnnnll'\~ nnc::::sl .' I:~ ,.f?f?THSIDEm- S"" \ ~ ...... l- ~ 00= \ \(f (( 'IJ/tj---u.
W~u~uuUUUt(6H7GANBoVDj~ UU~ ~ .~:~ J ~ -a~~{~ 1~~'-~ / ~ 4- ..~ .. ,<-fj; r ~ ~ \~'(\~~~
~~'~i ~~i~ :t CURLEW: IC'REEKJ ,.:J -' 1 '" o~. :,.. "'i 'J~" / d~~-Q/~~JL
, 'JiflL Eill=: U IgiJ 3 """a, J,,:' .,.L:"" ,6 ' · '- ': m.,::,n,"., ' vfh1'\.'\.~"<::\;:;:~11ti'
. :r~ ~ =0:,=0?~ ~Mj~r fJJ I:'d~f[ r7' C/ :.c:' .... :,." I J-' O~'\)'~,>. J1!
l cl/lJfi!l DUNEDIN :=~ J~ SOWN AVE -_ ftl U'lli~O!-\ ~ ~J L 'J, c~ _ L~l ~ v~7 ~~~~
'" ,-, U/J 0=-" ~ ' ~=<ri'>;" - 1"" 1 [JI!;:;J -/'=~~lmJI
," ~.~. illI it .ill1' 1') "'" . !3L,' J, I J'" f- '= CJ l
" ~II rl"'I] < ~ ',,"" ':;/~ ~_ :' '> :s -:= 'f'
(." ~ J I - ~ -' ~ ~:;? Ie;:: I' - ~ ~ _ JI!,r , .~Sfk580 /
~I~,' lIid[',%l::-llll\~~ u=! I ~ - : [J, ~. ;'P~ ~\9r.JI ~'r~L P9r-,
=' i I . ~ _~ SA~ ~~R,'S,TO~,?ER DR oill __ '2s::"" r= - 11 - - ~ - - 1 L \t\~D'REC1 ~UNOF~.l'.l 0 ~~ ==:=ier \ \
'DIRECT~Rl:J~(}ERr,IJ ID~I~Dt~ -- 1~~I.r,I: l- rrJf!JM;}jjj!iiJdiY~: ~~\~~J/~!irlJ~ \
'I 'liO Glul!'il~lfif. ~C=l~~ j, -J SR-5BO :ll I 1C7-'~1 lnJUliUlr"=. ,/LJ. .~su " ~_~ Cj;\~ ">>\
/;~L ,I /' J~' S1~~~1 [J~'l - - .;;- -=-.:......~\~.....~_J_ =-~~l @n ~ ~~=r~~ .!lDr~ <v,~\J
I. ~L]JL"J ~t~ o~u ~~ ~ : ~ ~ l'liP.'l~.r - ?i) ~'$'~ O~ :tFn~l:CREI ~nnQ,.\ \
J,J[ rn[-I\/')'.r n". - :";"l~ GOU.~I, "" ~\2l~'i1~ ,~"lQJ eJ~~~~~)
~Jll. E: ~L ~ ~ . -<) ,4 \...'2: '-~\. ~ 1~:H~u.~~'1~: L " "" J) 0 ti ~'~
~.--' ';.c:::: [] VIRGINIA ST. L r-:;: ' ''% ~ I~O-::,\,;:' WO~OQ !~~ .~~~.~: 0 '---.JIg \\
:::t~-a ~t~~6g~gOn~[ I~f/ JERR't :sEtiGG'H.< '~'1:"~ -'j}j/~'RDml :i:C"1 ,'f[ 1-' I /1 r7.r--l
~[]l ~'JI2J~gDlillQU~ ~-~ - ~)';; ~~ .il 11/6 't~'... ' I E"f,1:~ER~/St.:J J J '.:: ;.;..::' ci c!: ::-:J Jl .-:;, r, 'II .....r--.J =-'t[]OD~' "____.
l....Jui. ~=r\- ~ ;:::;;J nIP-Po J "'-t" - ,/ ..,-;Jl1f - _.ct:- - 1,.,1,. ~ U )
- J:;>, OW ~UL [j}5)JO v;2~€>""- II"';:"'" - "" / ~, I" ir:==-, ';1:-1 ( "'r. '[r- 0 (
Ic~JLJ[J~'~ DO[;IDDD'~;~~1IRGINIA ,,~~~: :~~'"III'-:~I~~ ~ ~~/~::IJJ' r~5/:13fU-U/IL-L'k'r,r;'~I: /1",- ,,-l:~:t, '>
.. ,- CIIl ., ~:~~ '-;if' ",...~~~~..........., ;:-Cf, ~ . >~~U ,- -: g M &;;;,~'I" /. c 1_1c li::J~ /
) f)1U~, f;? =i:~l1 ('ci;~ ~.~~ -:, '''- ,ESt " ~fi ?/~ - ~ )'1 7)// ~/ LL': ~ CREEK'" "- .I~.:.-.' \ 'f-"~. ~CI)J ,
"J~-~ -'~'= ~,~~j=:> ~~.':;3 "--~ ~"J ~ ~=- 'r:::: .::. .::~ "..n//;,1J ~::j - .j. l.riJi]O"'? :1
%~. - ~;:'''l: c- c~::=~ ~:rlnnrn"i=\ ~. ). ' = -::. U' -:" '''is . -- y /.17"')1:- (, -, - ': ~ S~FEToY1HARBOR r ~~o nri~aj
'< ," 1,'= I J\lIl1t:::I".1---1 ' - ~ .... ~"""""" '''''!!' -'~ CJ '.:lJ - ... ... I;JiJU/j
l~ ,..,........ --. n UNIONST.I--J (2) ~ & llJ """"'" = - = ~u" 'It: c 0... ), .::!;, r 1\ r..o '\ry,
..............~O............IIl...,}..... - - t ;;:'''::Q)''::;''''''''' ---I~ <;oj::;~ ~ UNIONST.. - '- ~.. I ~I vA
m%7,~r!.~!r.~~~~DW~nll5li11 JS'2.~ID~ ~ I.S.-::,,, ""':!F"''j'i -:~--."''-;:lI-' €'" :"- -"';::"0 '1'"',:, r n;.: j, '" J~~~~~:;:
~// ~oo 5: l! 2JUtI F,%:.o...su[:j U al 5::' Jr-:oNTCLAIR RD~ -.. ~ ~ ." I~ r II b.. '>,.$:/'
'///// l<I~ 'O~ ~(W'P ..... ;z:-;;---'FJ eo ~~ "";;~.l ~:5 . .:, - ~ "I ~ ' -'- ,Jl >{I
'i"/~.;; 1M @~~~ -'~~~~~~Ifff~ /NT. ., __ -"- 4 ~ _ ~~~ ~ CI) = _ =~ ~ ;~~A~ST. ~~~gg8mf '>
'/// 'l'/ 'l'// ~ ,) DIfDrc X/ Ar::::::::::lDD~~~~~~~. ~/,_= - ~'~-"'~ ." ~. .SUNS 'rar.,NT. - RD. ~. oooo90c..
(~.;; "// . LJ ~igU II~"""" CI) ~ ~..,,., r/f II. \>--. ~ , OODI',~~
,/~. " InO Cl)1~ 0 jl! I/JA ~ -- :g - -" -"- (,! t ~r~gs...
//~ ' '~l . ,j IJ "I cO - - ~ - ~ ~ - ~ ci:"'~ ~ ~ " ggg:-'
W '/: -1~' ' '~iN, ~%~~~S ~~IW~~~ ~' -" "'" ~ ,A ~ -= ~ . c:i d CI) !/ -:". ~ ~ ,"
~<< ~~JJI~~}~ ~~~~~~~(,i]2Q~.'~OOUDO~J11~ . U2J-.~ '" ct:A""'tt'L'IG"'A"TO-R"CRr: K~"SR~:O~==..,,==,!'J ~ :,~~ "t
. C/ V ~71fJ ;='Sl~ ~,<==.;=::.; ~ ,-,=OD~Dr JbfJJ~' ~~ "-/ r;;. ~ _ . #~ ,c-.
'i \'/ t,. /J J DDDD~~ ~v /)l..-=:J = =gOI, ~U " ~ ~ ~ '" ~ ..7J, 1" - : ",;;' -,' ~- V
'. '/ !"Ol~~~~ Iff' ~.,..~~ 2~~ Illm\ -.. - ffi~ii'~~~~' ~ ~ ~ , 'J J~~~'.i;i"
"/'/ :< r,~n,~~AAriITD PAL:8 ~~~Il!.U>T.II~I'.L~~- - PALMETTO ~ '_ ~~ "1':\ :" ~ ~~ ~ l'rWj~~
"/ ~"l L';'j'~f/'-' II .. -----'I - A!lO==t~ & UJ:': ~ 1\.- V ~l . '/
.,. /,7, CI)',~ " "''''':=:J ./'10== h;". ~ _~ (l) 'I>~ ""-<( ~~"" ~ .
,;,qi~;~~~=jl~=:=J 'v--.ru81t! ~tJ Cp~0 c:; i1):t ~~W 7?'& =c::J~g~ .
. 'N ;) ~.~ ~I Yi~~UUULJI(l) ~IDDDElnc: ~UlfUI"'1 .:: A\~' 1 t> 0 I l' - r.(d, ~ To
X " /: "l: ~ ~'I ..:tElDm3kE'WJDJ~' 2JD~BU~ m S7;:L l J ~ c . ~'1l -= "J 8 ~ ;;:!" DREWS ~~ // '/.
C// '// J l"[J I I~~~]" aowinn ~rwn6~6g6= I II ~ "II r, --I ~1d~~ z .. V/ '4
SI.0 ~ZQ r [~'~, :;'~ ~= f~~ ~~~~=~O=~ :1'" l' J1/lsT111, 9 ~ ~' ~~/. ~ F1
//:V/ ~ J -~~=\~r ~~.:.j '\(!)' PlJtr, 1 I ~m_,;1I\.;InJ BK"J '/ J .'1 I II' I 'I, I - 0 h:i 0 ~, ~
/'/ L OCOURT{ n ~I @:Jri ;:,== ~ ' j IU ~ ~ HIlI 0 ' "'
~r ~SR-60-lt ~.;J ISt~ _ST.~81 ' r-l GULF TO BAY BLVD '1 ~ tnnrn. U SR 60 0 ,- ~ '/ .
'J~CHE$TfYUTL 1 c, ~I== . r l' 1'8iB - ~~ffl'" ,,~
~~ ~'IUJJ._~I~. '1Ir[ {~~"'1i' I;,X';J., h~8DODOOD lW;.I. ,J" ".. I I ~~'l~ II,rIHt\,....'@?
/// " L c " ~, RUID:J= ~~' RD ' . R UN d.~.'
'/ ~;. ~~".~ ~.- ~.:i:.-~.~jgUQ::.'.' ~g I III [JOnill' ~R I ~.U.. D.O' D~~~;l-.J'L'i ~"" lJ. ci'U.. 'jnr'r'. J/::)~ V '<Z/ \~ Old
~.o-~[~~~ ~.'lD ~ =!!{ ,).Lc:?llil!J ~n2 I ~nntnh!D Ji" n~" ct: ni''$' [J' ~.:7f.JJ/ 'Tampa
'/ ~,::.!~~:~ 1~r'~o. D~'oonrD~~~~n'~lJllBI~:~" l' .:.," <I"~ ~~)~:j ~rn~OI~I~[}~i~ \\0> Bay
~'~1 "'" ':,L..~j1' . ~ ,Iooorll:i I ii~ ~~~ ,'~~~~r I 5 ,[ ct: I w.r;z, BLVD. :::J ~ r~~ ":i~
. ~-;:~Cl '" 0 "-::JL ~ lcr :lll 'fl -:5'=='''l:]= ~'~ I I I I I 0 I ~ ill 'I ( /' I I ~ r/,-<< 1\0
,\ ~;:, ~ BELLEVk~.;Ja v;z. I~~~g ~(l) 'J ~-=~i~~5= ,L d 1 ; II ~ :1, ~, I,!J 'Pi I ~. \\~
.,// ~~(.l8~F~I6" ~~[lZillJDDUllii~ I ~:z:~E5i I =- dl,l, /IJ '1 _ Mj r ~\," " ~,~
I ~-JL ~=::::::JJiJ'91l1 ~ o~ \,\' ==;;" NURSERY,,,, VR'CI L r[ , i\Gl
I cl><,//:\lfu JOO~IlJI]O~uDOD ')~.. ~ :~: I : I ( ,I JiAU.EN CRE~ )J...,. - \r
'/
,J'L1G;r' ~~. 'OOOrJlJ[,lo.!: fiTA!i ~ ~. III 1'1' I
'I, 1 tilL:Je ','LU ,]e; ILWIVl.1 =:~.~~ l~!!..G..Q~ I )' I
r ,'-, ,,)~, 17/ InfUN. .la~DDDU]~[]CEi4YOt, O:-"\( I ,
''\
oX.
~
'/
'/
~
''l/
'l
'/
. .
~. .
/
.
....~4~',.... - I
" ""?~;(.
" .,"..,
.' ...-.t,;,
?)()({)~~/.
r'/ i
'/
~',
">
~~I v
/~~ ~ '9/
j' /f4~
~ ~
) 1fi~ ~
j/j .' ~ 0
t _ r/ /)'//1
t A' . <<~
! J~l" ~ ~,
,f '~il.!; /;((
~.
'~/"'7; / '/ /:L
~
'/
)
')
N
w4'
jt.
~,
','
I\.
\i
\\
\\
Scale: N.T.S.
s
FEMA Special Flood
Hazard Areas (SFHA)
and SWFWMD
Drainage Basins
-
Figure 7
Date: 4/17/2009
Source: FEMA 1 May 2007
LeQend
FEMA Special Flood Hazard Areas (SFHA)
ZONE
~A
~AE
IZj AH (No Occurance within Clearwater)
mVE
Drainage Basin
. ALLEN CREEK
. ALLIGATOR CREEK
BELLEAIR GOLFCLUB RUN
BISHOP CREEK
. DIRECT RUNOFF TO GULF
-- DIRECT RUNOFF TO BAY
. CURLEW CREEK
. JERRY BRANCH
. LAKE TARPON CANAL
. LONG BAYOU
. MULLET CREEK
STEVENSON CREEK
r::.: Clearwater Landmass
Outside Clearwater City Limits
.. C~ Prepared by:
O' 'I -, Engineering Department
JI learwater Geographic Technology Division
!::~.. ,-. 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information dala is furnished by the City of Clearwater Engineering
Department. and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
asSOCiated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
""\'~'ID' 0
:... L--tjG.CS]il:-~lijjr~~Fr:~
~ 0 I ~2S~~~~~~f~:
: O~~Ot]r:::&~C:::=J (')lc1
, it'll~~\~~JIU LJ~<s~, (2 .vc,
i~~i~@.fJfl~~~~dO)/~~0.;
~ I t::3f.DD01l!l)/0 '2J" D) >, nt~'
Cl: ." .~, I~C-.,~' "!.<2' J;j} "c:::J~-: ~ '(1
~ I : g ~~~(~@;df?J. i .
a ..J 0) I I C~"d'I;;:/ :;) ~.....".{:j: ,u::
Cl: ~..... D , '>dr, 4. "'iJ, '" I" ,
.... rh d.'l r.$l( C> I :
DUNEDINI, CIl SOLON AVE ~ 0:-' ~ " -~ u I '
~ ~ II r", t? ~~ ~I ~~'G7 ,rI11tg:1IQ\H::-~ : "
ili I: I ML ~'5'~ = ~ I ,VP~:
~ l: f'o,'"iI r'J~ ~ >0 ~'.. c ~rl ~.:'...., SR-580
SAN CHRISTOPHER DR '; I 1~\~0~- ~ ~;; L11. '.
. I '\l:iM?~1 '01 .
: U l' 'I J~) J J'c-o., ::;':
, ...~~~:~O...~ ~~a~~'~ ,,~g:~:
s1, :S~I I 'is\of>~. )2L['~q . \0r:~rJI, "'::= .
-J-~~ :~~I \ \ u1'l1~ {~/,:\\~~ -~10,~0 <1:~
VIRGINIA ST. ~llD\61~>~~-j~~ljD~~~J~': .-J ~
~ )MI~~~~i'r~o'~~~~~I~:r
~ jI ~ :.~:G~N~~~~~...t~~~~~J ~ 1:1~ ~ ~~&~~ 1.0
:::> ~ c:i'~C7 ~ LJj ~ Cl:] c-= II - ll\1~
LJj ~ ~ Cl: :r:=' rt ~ ~ ffi (J I ~ I :l' ~ .
~ ~ ~ Jr 1f ~ : I~ lJ 9 ~ ~~~C(~lr;k-r~tllr L" SAFETV;~HARBOR
UNION ST. : 0 n · IJ.J 1~R]~d1~ UNION s'P. \, .
~ :~~'~'~':.:i~-j~';': l~:r,-":""'ji"~~;;';:iU}r' ~~ 1iqNOi} ~ ~ [~r "- OQ'O'~' IglO
ff:~=J~I;~t?2~ ~~ ,ro~~ ~~~Du,~,~~l~0Jo ..~ f?;. U( m1!~ ~ J I! :1
(jJ.- ~:::> U-.lJ:: -- L..,. =~~~ 1 /-~n-I' lC;tJ~ 1st I:.:J lO 0 ['L... F'i~._~
gl -~~,Si ~!=- ~DIT,,~I~[L~~ull;,t!'C?I~~l .~~~~ "l'il ~~II, lCJ Oil.. .CIll Il (.-'l]J~~~ MAINST.
lj]" ~~ljJI t"'";' r--- 1c:...'Jll=" c::SUN~ _.~I'!L~OI!>'~1~l",,",U:1D.JJ[])~~ Jilll- roJ~~ r.'SUNSEt~POINTrF ~TIDJl~:'
(;~~ I,W~r 1~! ~1[QKJlu~~~~~~ .' ~:~~J!'lI:t-! ~.f1'. ~""]I}'i~ lr
Msg'/\-~~R1' o~~~(~jG['-~~~~~~~~~~ --O:::r:J!I!F~I:~r.:~,1Brr~ ~rv.~~I~M[[ ~ ~~rr~-i~ II:
:~D521.jJ&. ~~1b~ j5'~ ~/ -000000 ~~I Da_~{ ~"~ )l1Ji -mt&:.R~=~ 'j:
:JDA7~~jJ~DD~~., V"v ~~1~i:li ~~UDDDDD~D< al ~ J~ ;o/llLJUU~~~I~, [11 = 01: ~ .
:'l~/Ld~~~~r- ~~=J~l LnGooO~~~D: '~~FA _~,Cl:_ ~~~<n It] lllh .Je.:71 Lir>:c2o~' ...~.,
:'J'Cf~~~~~~ I~~! r~ <~ ~r--"-'I Jnl~1 ~'~ fJr-' II~ ~ ~v/(jl-~ I J~~~'<' fn ~__ ~~~:
....:fi&~,~.~~AWJL!'AL"! ~J;;J!G'A{3f~~rfQ]P.!ill~ "s rcPALM.~l"T01!~ ~ ~ , U6U~~~!/ d 'l;;r=(:=Jfrg~~f/ ~'I.'~..
.:..J~O[1crh,~.::J~,~l',---Jr=-lr '" CJL:Je:=,QW I~~ <0 i'\ IL ~l~~0"'-J-.JGJpjO,~ ' ~'~===corl .... '.
'. JDCo.::::" <(~CJ,!!i:-JI' - lc..-J?l ~ r\ :~\ 'm ~(i l!ono~ I~ ~V&"\{'.J!"i'211 t:> ===C:~ll' . ..r
hl~'CUjl~~='2i=-'iLk~ '- JL J[',"\i J J ~_ '1t>.11 __, Cv=.. ~.-JJ:: P Q,16}~ 3~~=~SY~~' ..' /
:!ti flT1(~,~L JL '_J' 'UUiCll IDO~8~s.::J lIU r.llnrnlll:yI~~~'c:JDOO@~. I . ~ I ~L "", T~[ ~~. ~~. .'
.:::; ru~uc:JD Itl[ rn';lr DODD 21n~noo ~I O?' 115el ~SlOD~G:/'~' 10 I v...., = .'0;' .'
.~<(DCJI]IO'OCJD ~DREW'L1L _J DO ~U~Lt.,;;, ~r: ll'~-1[-'~OD-/ ~ _ J~'DJL '_ DRE~~~-{)__ ~.:L,. ..:'.... .t..
.t~B~~I~~~Ep3r~M~~i~\~~~~I:-~~~~~OD~~~[jDn~A~~~~~~~Do~~ 0 ~t J:i-IO"r' .~~~ -bl:i!l- .., {,,'1!~':' ....:
'~'o\'UD~t~tR.17~~1'~J' J%<J~nC~9~.... ~n (Jg~U UII.IP ..LiI/i. D.ODDOD~~lXJ u. ~nn161"'. l~: II n.illTTFi?i1\l~l! .:.. f.'- ........::::::::::.
.~~O. ~S. R.'60~.~_~L~.:o~gto~ "ST.~o,5~,._ .JDDllDCG1'-LB[7:0/:aA~rB'ZvBUL5DD. ol!5nL .. JLo .::!uld!l~lJ;Cl~r; lit: L.. .Jt.Z:::::........
:.::JooCCH.$TNC.t7."L_Y .:=l;:;i?-6 lTIc:::J=[JDuODDl 'IGD[f.l~n~D~" ~ -J'J II' - :-' lr-::Ill:I\W t>lIO~r'" .
:J!!norulo~~DC-lt..c.f~l~ \Zj~~REiD[lODDDD;r.I'c:=;:;lUa\Jl.-,\!11 I( . ..~.JUl'.:,~'"
'~Uoro[ - ",.JDLJl':SLujL':i~ ORUID.:J= IP~ UDOf. u: = ~ '..-
i~g~~:~~~~ggr1Bfjll,~~nlfann:ir 1'='H:~~U~~~Q.[ IUD~~~~~~!llJ,[ -~ - ..~..,
".J=C!!?I[\IJ~DD ~ =!1!tt \Ic-.JU~I ~n5!MQ ~~ l)ggg;:S~OD ~ =~~ . ~.,
<&''i]~ ~,~~:~g! fl~~i':hnn~j~~~tgn ~A:P~~': ,," [~'I[@~~li~1i1:~ l
~ 1>}~::i~~[)~IDOOO~t'~nr~c[" _IE; ~ J~ ~ RD~-"-'i~, = J~~::~UYD. 1~ !
~ a ~ d:~~\ ,OODSa: ~I ~~ <{ 5 ~ 0 ~ j I~~ _ i3J~' I~U~(F~J ~....
"BELLEVIf.'~~ J ~c5 e~ \/'p ~ ~ I lJt@1 lfuj, )01 ur~ I ~:
~ t~J\lnou,ln[~~~~~~~ >\F1-~ ;NURJE'!.-YJLE'!"~~Th\~~)I'1 ~:i~.:::~~)
BELLEblRJJ :;'U}\lD~~,~~~~~:"'''~;f''~.:''~': ::.B.'F!'J"FA/.R.u... . '!E. __ : ~~..~~:~......~.:..(-= :'.:>'
.~'.n..:.' ~.. . . '. 'I..~.
L.f' ~...~~. LARGO
........
Gulf
of
Mexico
I.
. .
. .
I r..
, .
','
. .
. .
...
'I'
I"
:,:
, .
. .
. \+
: \\"'.
jlDD~':
:nO'&)j :
:,0000"1:
,), O'
. '0 .
. . I"...,
'DO OL ')1' ',"
'Or':!O" . I' .',
:O'~IO: :I,'~.~"~
:D,<l:ln: "(I:":i~
. I)- IJ' . \ 1'1'.' '.
:O::5:J: :_ :~~~i~
'; OCC:JI . (/).\.,. ~."
'~C:h. '..t;.,l\"".'"
:~~]: i;Z,\~~\ ..:\I~
.=~~.. tC)'......\.
:gu '.s ~\\~.\..I.'..
.= Rn. .........,___...
.c=!ouu. ,....~\- ":.~.'
: q~..." .~~\\;;:;;:
BAYMOe'"GL: ...~~.. .......~.
. :Ju.f" '.'\~' II.. .\' I'
1..:])1 ....!- ",'~.'\:,,'
"lDI: I;..:~'-;~ ~ :: :\: :,:
. I' . h~'(~l\"'I' 'I' "
: }.o....!J.. '" '+;-~LJ ~:~ :.: ,'':1:
:-d~. ...::.:g-:~1~'~1'.'.1:
:~O.. ....~~..: :.: :i:: :
, (::0)"......... ";'. ~..J,
: ..0/:........ ....."!'~ . ~,..
: ,I.~,._..... 't!~.:.r,..o~
. t1......-.. . O1!-".-1;%
. rOJI~~~-"IIIt:..... ~~~~,-'~<
. :.J .......- -~........-. u~.,..o~
'. <t~ ....... .~.~,:"fb-
'''. - ~':............ ..~~~..
.............................:JC::Jc.:::::::>). .Ill,
........ f2J-;-..
..t ....
.~..
.. \ ...
..\ .....
...\ ........
, .
, .
. /~
'. ~<:)'~.
: ~ 'fl.
: \)V /~~.
: (j .,.~..
. ,'.
$: ,to
;p. .;.
'. .
"I .
. / .
~'. 'I:
: (1--:
. !.
. "
: 1/:
. f o.
: 1/:
: /A,j..
.'~N"..'
.. ~'.-:..........
/.:::?;.~.
.......-'..~,
Clearwater
Harbor
CURLEW RD.
MICHIGAN BLVD
:?!
'4
:;:j
!-.:
..,
'"
UJ
~
lJl
'5
m
UJ
';ll
'5
Gl
m
~
$.1;> ..
. "'8.,
OLDS~AR
c
0)
II)
~
N
w-<?- E
s
Scale: N.T.S.
Clearwater
Waterbodies
Figure 8
Date: 4/17/2009
Source: Clearwater Eng. Dept.1 Apr 2009
Leqend
D Waterbodies - Lakes, Ponds, Rivers,
Creeks, Ditches,
and Swales
r::.: Clearwater Landmass
Outside Clearwater City Limits
ll. C'-1 P'epared by:
o ' Engineering Department
Geographic Technology Division
~~ .earwater 100 S. Myrtle Ave, Clearwater. FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City 01 Clearwater Engineering
Department, and must be accepted and used by the recipient with the
underslanding that the data received was collected for the purpose 01
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability 01 this data for any other particular
use. Furthermore, the City of Clearwater assumes no /Jabl/Jty whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
Gulf
of
Mexico
.
@
~
.....
~
..
-
,\~ .
Clearwater
Harbor
~
~
o
.
""'"
0:>
~
CJl
o
m
0:>
':xl
o
Gl
m
N
W~E
I
I
s
Scale: N.T.S.
Hurricane Evacuation
Zones and
Evacuation Routes
Figure 9
Date: 4/17/2009
Tampa Bay Regional
Source: Plannina Council I Jun 2006
Le{:lend
Evacuation Zone Category
Zone
.A
.B
.C
I I D
.E
- Evacuation Routes
r::.= Clearwater Landmass
Outside Clearwater City Limits
u. - Prepared by:
a(CI t Engineering Department
Geographic Technology Division
~ . ~arwa er 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)6624760, Fax: (727)6264766
~ www.MyClearwater.com
Disclaimer.
Public information data is furnished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodpl~in Management Plan 2009
'.
'. t
. .
o "
00
00
0'
:.:.:
o .
,0
00
o a
a a
a~a
a a
::, a'a ,
a a
a .
a '.
o '.
It .
~ :
.. 0
~'t~ ! ~:.: ~\
. u.i . '" ..
. ::s . :.'.~~~
: ,f~ : : ::~.~ ~
,5 :_~~.~\
1~,. ~ f :~""~ ~~ ~
: <:: . l,t~..
. 5(' \0 ~~ -;."'~
: ~.'.: '.~~."'....
. : .:."..- ..'
: ...~. ':~~~:::
BAYMONT I. ': :..~;.:. :"N.,
~: : .~ II ~,'. ~~'. .,
: : ,. :.-:. ~ : ~': ~T: :'~:
. . ~ I,' )> . .' ",a 0 a
I . .'~ < ',,~.' .'
: ~. ~....'.~ ~:.i:~: :.: :
. ..... .... ;;.......OI! ~:-. '''I ..,.
: :... ...!,'''~~;:~:: ::;:
~~:".... '.:~:~.""'::::
· 0 .......: '._ ~~... .....
~~~ :...... I, '.~O ..
o tl.......~~ ~ ~~
. 0 ......~.. ~..t_..7<
I, .......'.:-~.... ~.,~.;._C'\P.
.... ~~~.. ..... .~.:~
", _ ..~:.:a:...: ..~"'.!
.. ....... ....
:'~'Q""'iI.. ...... ClaalWatar
a a Harbor
1', _' ~<:). .,'
h,.: 9)" II'
1--.. ~~ .
::,,~\)~.,
. .'
. ..
.. ~:
. ~.
.:n.
'/{O'
.i.. :
. .
.i"{ .-
'/'1!
:~-:
..~:...
.- !JtAa..
~Jm!~.'
:,.... ~r.~:
: .~~ .:.." .....
Gulf
of
Mexico
fit
~
.
OJ
~
lfl
'5
m
OJ
~
'5
Gl
m
N
W~E
s
LARGO
Scale: N.T.S.
Hurricane Storm
Surge Areas
Figure 10
Date: 4/17/2009
Tampa Bay Regional
Source: Plannina Council I Mav 2006
Legend
Storm Surge Areas
Storm Category
.1
.2
3
.4
.5
r::.: Clearwater Landmass
Outside Clearwater City Limits
u. - Prepared by:
o{{;l ' t Engineering Department
Geographic Technology Division
~ earwa er 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)6624760, Fax: (727)6264766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department. and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodpl~in Management Plan 2009
Gulf
of
Mexico
(\
----~~
\"I/'::"::=- ,-
N
W~E
S
Scale: N.T.S.
Special Needs
Facilities
Figure 11
Date: 5/4/2009
Source: Florida Agency for Health
Care Administration I May 2009
LeQend
rn Hospital
II Ambulatory Surgical Center
a Assisted Living Facility
. Nursing Home
FEMA SFHA (Floodplain)
~A
.AE
. AH (No Occurance within Clearwater)
.VE
1':"1 Ponds, Lakes, Rivers, Creeks
r::.: Clearwater Landmass
Outside Clearwater City Limits
IL -.. Prepared by:
O~'Cl t Engineering Department
Geographic Technology Division
~ ~arnra er 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department. and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory. As such. the City of Clearwater
makes no warranties, expressed or implied. concerning the accuracy,
completeness, reliability, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
~..
.' '.
! .~
. .
.. ..
. ..
,. .
:(
. I
~~
: -..
.
..
.
.
.
.
.
.'
.
.
.
~
,. I ri~'!
., ! ~ ~\
.. -.: I i~ ~
: ; ili'\\
Jt tu; \\h
: <: ~~t~
COASTAL : ~8. ~ 1 ~~
BASIN BEACH Se ,.\ ~:~;~:.~..
~ ~.r. ':;) !)~-rft'
BA YMO~T .., :),:~f" I-! ..~,
. ., f' ,,~,'~~
.. i' .... ..,\..u.
~ .r ....<.,''i...':IIJ
· l' I;...... <; '1i~" .i.....
: ~ ,~~h'r~" "H~)
: ' ..-~:, ~~,. .:, . ~i U~
II ct....... ..~.~.., J6f Pr." /'-..
: o~. ......1J,:1 :, 1; f
~ ;0 "'bot....~ "... -0,; . ..: ,
.. 0 ~P"..wt" ..,~~.~. ~
:~! ....~ ....
. -,s "_,"-.J~~ ',h '. o~
;.J:'~~~ 1t. ~.~~<
~, ~.........~~~ oo,.."..C'~
'\ . .~~. . ~~~h_
... -.. ..~. ...~'-t-
'~"". - ~~_."'~~J; , .'t..~
".'!~~ ~
~ './
.'"'. ....1IIrI.'!
e. '~,
... ~.~.
..~. ~,~
COASTAL \~' -4Q'}
: '0" of'
BASIN BEACH l \')v /'
.~ (j .r
l' .~
Ij"
/."
l~"''I,
lit
.-,'r:
.~ 1.1
" ~
.' . t'I~....
l!~~r-:r;'
, ':''J.!;' '~l'
~~"'~.'''JI .' r.
~~ ~-
Gulf
of
Mexico
CURLEW RD.
~I? $8-
."1
OLDS!JIAR
MICHIGAN BLVD
c:i
Q:
~
u
iiJ
lD
~
o
::;)
f..:
..,
"
DUNEDINI
IE
I-
C/)
Q:
:::>
~
ii:
~
SOLON AVE
SAN CHRISTOPHER DR
I'
51,
I{>~
'"
VIRGINIA
ST.
ll.i
:s
"
ll.i
:s
q:
~
S
~
:::!
SAFETX~HARBOR
ll.i
:s
q:
S;
U
~
rE
<:)
01
10
~
MAIN ST.
Clearwater
Harbor
tll
~
(fl
'6
m
tll
J;)
'6
Gl
m
N
W-\r E
S
Scale: N.T.S.
Repetitive Loss
Properties
Figure 12
Date: 4/30/2009
Source: Clearwater Eng. Dept.1 Apr 2009
Legend
e Repetitive Loss Locations
FEMA SFHA (Floodplain)
ZONE
~A
.AE
. AH (No Occurance within Clearwater)
.VE
[J Drainage Basins within Clearwater
D Waterbodies - Lakes, Ponds, Rivers,
Creeks, Ditches,
and Swales
~.::.: Clearwater Landmass
Outside Clearwater City Limits
.. - ~ Prepared by:
O(CI t Engineering Department
Geographic Technology Division
~ .' e_arnra er 100 S, Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipienl with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory, As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliability, or suitabifity of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
Gulf
of
Mexico
;~
. .
. ((...
. .
: .'~
..
.,'
. .
. .
.,
:\~1~
I. \'
~1f:',
:~. ":.;
I, ::--: i-".
: ... .uJ.':
. . -.
..... ~ L. .
:~~'-'"*;: ,., ,fI',
'Ii,o. ., '.'
'e . r-.. I'...
'" W . " II
:ll:S : : :.,- ~
: e '~ : ::: ~ ~ ~
: rl 5_: :_:~ ~ ~ ~
.~/g;:. IU) II ,I'
:~q: '.~ I:..~ I,
I-=: ~...J' .,2 i.' '" ..
:~~i.' ~.~ :.;
:~~n ~ '..~:::.*..:.
:~~.-;; ':. (..~':.:.":
BAYMON~ ,::-.:.~....:...
: =if.. -: :" ...... :'.. II ~ .
: 5, I~ : .. :..r\~ ~\ ~ : ~ ~ ~ :
. -,. ~. 'J:..'~>',\.' :. . ~ .'
:, I, ..~(~I::::I.::
-.,.... f4..... ,., '.~ JI ,.......
:-j,~.~ -..:-.:_.. / :. .',1,', :
~'?5' '. ..' .......
: ~;f) ~'..... I.: ::.. ',,::: :
.(0'...... ...4,~....
: ~.:...... .:....:.t,..o ..
I r().:..... ~ ~ '.~
. ,0 ~ ~~...: -r:.~~~ ~<
,.\ \\;..;:.-....::;::: u~.~~~'~U"H_
I, ~'0. -.. !':J-
. ..... p .... . I, I,
. _'.:: _-.. --::._..' ~ It..
_. '. .J.
'\'.. .... "
\\ .. ...
.....~ .[........ i' Clearwater
. '.
. r . Harbor
\tA/
:' ;S~
.._ (j\S _..+
. .
. .
._<t
. .
...-:t:....
... ~:.,
:2:
. .
. .
-, .
. , .
: ,~~:
. - _1.4'"
. 'iH....
/l..~......:.
:.'.::::.. :
,.,....,.:,.- --
),I~.P
. /a~ rN Ii~ ."
Q
I.
I'
I'.
N
w-<?- E
S
Scale: N.T.S.
Critical
Facilities
Figure 13
Date: 5/4/2009
Source: Clearwater Eng. Dept. I Apr 2009
Pinellas County I Apr 2009
Legend
~ Fire Station
o Police Station
m Hospital
.. Shelter
.. Special Needs Shelter
U Airport
A Hazardous Material Storage Site
FEMA SFHA (Floodplain)
~A
.AE
. AH (No Occurance within Clearwater)
.VE
D Ponds, Lakes, Rivers, Creeks
r::.: Clearwater Landmass
Outside Clearwater City Limits
u. c- Prepared by:
o ' " Engineering Department
Geographic Technology Division
~~l~1'\V'ater 100 S. Myrtle Ave, Clearwater, FL 33766
O~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliabifity, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodplain Management Plan 2009
Gulf
of
Mexico
'.
. '.
:'
,
,
,
,
.
,
,
,
,
,
.
.
"
,~.:
,
,
,
,
,
,
: :.:':',
. ....
p';: " I'
oe:( -. : ....: ~
>- I ... '. .
:5 : : :~:~ ~
<(0: :~~ ~ ~ ~
',. .~ ~~ ~
~. ,"- ,'" .
~.: '.q ,'ra.
: ". 'I ,':-.' '..
I . ..........
. . ..~..~...
. . -.' :.... ..-
B'^YMO',', bI'~ ~ ...... as
J'1 "" ........ s- " .
. ': I, .........
. . .... .. . . . . .
: : I..:..~'.;~:::~:
. . ~':'", j",,!< II. . . .'
. . . .. .' . . .
II' 'r~:."'~".' I,. I
. ...4..iW'.II .... :. .'. ,', :
. '''. .... ....,..
: Q;s.l.... .... .....::::
. eJ'f'....: .:. ~~.....
: ~ :...... -:'.,'4,0 ...
I C)....... ~ ~'.~
: 0 .:::::::....~ '6-0:.7<(\
I, <t~ ..... I,. "~~
", ..1'......... -'.:--,
.....~__ ..' -.II.
...~....
:',
'I ",
. '.
I. ".
'I. .' ....
. .
. '
\ _ ..f>:..-
. ... to" .
. ~. ,
/(j..:jV....
. .
. .
. .'
. .
. .
. .
:~~.
: ..!!J
. .
. ,
, .
. ,
, ,
, o.
.: I~:II
.. . .....
. H....
.: J..,:......:.
. S'. .. .
,...~.. :'.!.{.--
Clearwater
Harbor
;:p
CURLEW RD.
$.",
'T. $8.,
OLDSMAR
MICHIGAN BLVD
c:i
ll:
ll:
'~
(J
-.I
llj
::!
o
::;;
I...:
....
<{
DUNEDIN:'
~
....
C/)
ll:
:::>
~
0:
SOLON AVE
SAN CHRISTOPHER DR
1
oJ-~~
,
~
~' 51.
VIRGINIA ST.
~
<{ ~
lJj <{
:$
C
0>
It)
~
tll
~
(f)
"5
m
tll
:Il
"5
Gl
m
N
w-<?- E
~
.......
~.--;-;-..
b\RGO
S
Scale: N.T.S.
Sanitary Sewer
Facilities
Figure 14
Date: 4/17/2009
Source: Clearwater Eng. Dept.1 Apr 2009
Legend
Water Treatment Plants
m WPC - East Plant
. WPC - Marshal St Plant
[I] WPC - NE Plant
Sanitary Structures
.. PUBLIC LIFT STATION
.. PRIVATE LIFT STATION
FEMA SFHA (Floodplain)
ZONE
1721 A
.AE
. AH (No Occurance within Clearwater)
.VE
D Ponds, Lakes, Rivers, Creeks
r::.: Clearwater Landmass
Outside Clearwater City Limits
IL. Cl7"'>.. Prepared by:
o ' Engineering Department
Geographic Technology Division
~{11~arwater 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department. and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphic infrastructure inventory. As such. the City of Clearwater
makes no warranties. expressed or implied. concerning the accuracy.
completeness, reliability. or suitability of this data for any other particular
use. Furthermore. the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
Cit of Clearwater Floodplain Management Plan 2009
\W ~~w\J~lillill)\C:~URLE~t.j~~l. -JilU~~~'I~:.~.\ ..__~~'. . ~ .~....,. ~ i~~ .t= ~~~~.
/~.j7J/~. . ru~5UULY2~ I~~OQ1l~~ WJI.-~.-..I- I' - p~ ~)OO~D[ ~ ~1~fS,;~~~1~...~ .~~ ,~t?,$8~, = J(j ",
(, .~. = (~---' Is;: ~ I :J~oo - c:s~~~~ @:ji~ . ~a:i~) '''.
! ~~r rnn[SJ~ nfl\\"'~ ;~M SfD ~ \ )"'~ ~)( ~~, ~" lE 00= ~ <<' 1J::YL)
1.~~1,~~~~~~ErGi7GAf/B[V03LYJuu~D~~~-!~~ .1fS--'~iUt~ ..~I.\Wlt~~L/./~,i~J l~; JfJ,..' ~ <~~0~. -~~
..~],~nll[~jCl~ - 'l~~l!:l! ~, "T:=lll J . 'e f::,~ ~f;:f.l;':'&w. ~ '-111111 j rrl \ ,,,.)~.;f41'5'~
:<t1~~/. = u U g.~r= (lJ 2)01 (\~L'~~~ .JlW. ~g h\11~-1 - r~. ...J2't:l~:~. .'\ 'v 0,)~"';>~':'''';~~I[c
(1.,-;';, <!, " /~Q s:=I'fl 1~ LJl'" ~ f'1'("""C'::::::J . C' f:i' ,'>l!/I 0..... oj I.' 'ODL. . 't:lA'/'-,,""-. ".~.-'? - U
v,^ .! =....=0 L::: 51. D =. ., = C::.\I ll: C:>.'" '0= '0. \\-tJ J ,~
VD1$hD JU\LJUln1lil:f~ ~ i Sffi-co [il~ :/'Ji"'= d~'){~I^ '~1~ '-.;~ ~\
::J~@QI!~W~~gw~~~g=.1TI~'I-~~mr.~ rr=. i. ..... .~. l~~t I L..l.~.~.c?~.~~.~:ij.7~1....?r J~~l!l~!i~' \
d JI ~r=lln'D]~2J ~ l~Jrrnr~nnli I -{:II I ~ N~.-J~L! -/ n~~bJI=ij//Jlill\ \
i~, ~IIII!: D~t~ ~nj~~~EnO-J~JL 1~-~c:nJ[j I~.~.'" r~)~nf(~~1 . I~':~ DO ~ ')
. ~ If' j= /nfIUJJ) ~ - JII~ll I lnnnnnnnr'~ ~/l1 ~S\~'-2M;ot01[~ a l~~ ~~ J 1J1[@B7, ~?Sr1 Q ~\
!~~CJd~~~m O~~~~ . rJ. J!WUUlJ~~ \\G~1~\7~~~.j L ~3' '.(I~.. ~~ ~.~~tn~
J8~~Qrc:W~N~ ,ill! ""' IJ ~IT~ .r~\bJ\~{-;1\j>~~~~l~r~h,s-.~l~" Ul,
lEi~~. ~~~, ~.3. T ~~..~IJ.. .... ii~l~~.' "~~K. ~W;~ I,~';; ~~(fJ\. J.))ll~I~I~~='~~'~ 'i
~~~r~~J~n .~~~J<G INIA.... .~~~~.~m~l. ~ ~ t\-~J~~~"t ~I=~ ~~j".:~ t~~L ~. i~h /~
ZJ~W '-. ~~~9rrrIT~ ~ CO ".'1" U1ljljii.";~~ ~~ ~. ~~ ' ", ,~ (] ~. i . @1~~D .~. ~k~
ln~!JJ-1,~,~~:~jr ~! .,'=~~~~~ OE1!1'5'~ ::~' 'lirt L,'_ ~ 1;; 1'~-"1JU'\}~g671
g:../LJ~~~.. c:::!'=. . Cf.:'i;':t~ . : '. ~L noon:g., ,,[i:J.~ ~ P.'""' ...,~. ..,.ca."c~ ~ ~. .11 '\S I~:\IDJ~
Q/ D : "~~~~I 0 IIEln :'.. II _ U' ^J[~N=".~ i='. ~C:l (' LI '0-;- 0'''' I ~~=, '
12~~N~=>,cr~ I ~r~N'c:cv~~r8:~~ !~O~'- ," [~i3~_~ . ~c~~~u~ t 1~ ~~~", . \ "'~)/
~:~ i~~li ~l. B)5 ~!, l,;..- u~ J.MONTi:;LAi~i '~~\;S;;.- ~ ~':5. . = ~ ~Oln.o'lI I . WU~'<.ss;':l
(jj'~ ::::.~ ,. -' - "--""bl.Ul';;,;- ~~,. -~ "'TI!l;;;; "11 .:J' co'" r"...-- (I I"H-'~ ~ ::JoO[joooo~-:v~
': 0'0'-" '.:>. ) ll.-----J ~lC [lTI"TI1 !~JD '/: D i,l CI)' ';) ".. II C1~C1 PO'f2l00000 /1 '
& L..- ~~, ~ "'l'C.. ~v2~~gD1JJI'~;, '9,1; I~ Y, ~J~f .~ i iJg III~ }~ .~S~~SG~ ~;OINT~7~~ _______~~!t-'J~lJg~ ggggg~[~~ (
,'i.P..;\ Q!ll<.... ;;Y..': ""'., .~~.~u. ~~~.,"'.!r~.==~~.. ~ ~~~IOO~ ....~.IH.~"'Y,.o~~..J:~_.D.O="'.~. 'r!iJ~rj!l. i!~gg!g~r'"
t "JY.~~~~C!l~~~~~W::~~:i,~rJ' ~~j.~~~ '1.Ra~~J ~",i1rw~~'
jOO~'.~.IJ,~..~.,..~.~ooLot:n.~~.:7Jj/~'~.."-~.~~~.~f.'~::\ ~.L-..'~~.~. .' 1..Jrt......,I~..(~.V)..I..IL.. .i~I!;I~.,~ul' lll"."~.~I... 1....ll~~7 '.D.'" ..~
.-ljflJ!h~~~~~\,.:'/;~ 'g~~~1j~l, ~ =L .- ~ ll:~~~ ~~~:d >L I:!f'UJ ~:=/;;J . r q..~. ~ ..... "i~;
i}/D{7~ DD'~~ ~y~ ==;P"ntl "'. - -.J ~.~.. ~"<-~ = I 1~I!n~!II(,~' 'n8,."*'" --cw,:
u}lODi~~ ,llJiD pl~ ~~)JR~m;o~D~'c-!. ~\~:=---I\""r;~ . J~~",,~ -,~'_F'qlll~{'J-'J l . ---:/ ....'~..
.:..I~~nD gEe,:;,~r.!lJ..~i 'lI'.1.1 Jlif="". ~ ~ ~~'~.~,'O:==I. l. ~~\. It:-. .~~ ~:~ u ~~.~ ~~f~h!l . ..... ~.~. .~'6.K il~. .' . ,'/ ,:' ..
1.fj['!JOf:J'<f.-:JDC .qt6!.!~ ~ m - ~~O~J loIJJ. Of' :-u; '0~V"11filj1 !I.l I, . .... ....
h~' l[JOiD=)[:~~ ll~) I .~. .. ~u '- ..:t Ii.!. '/;'':I~ !3~ ~c--u- =I'i '.~i:' ..'
I'H'TID II II Cll DODD ~CJ lJ IT 0 1DISC ODD 17:.;-.7-": QtJL == . . rf ~ r--.;l ~...:t' '.:
..1~i RggnOIQi;,f\fJO'l( OgrJll[ Ilm~l~o~ ~f ggGt? .~,~]i~4 : ,j ;-l: ' . ~'?,)oD-~'.... .....~,/
~~i~~g~.=~~~m[krw.aQIJ~l~g~~DDD mCm9DD 0 tlh IJ JL ln~~f'-I.fl.i-r-r ~r~~ 6 fJ c-~ ar./1i~.:'. )
~J.djJDoD,;=~nI]DDO~~o,==D L!~lll;'lIl'mJ IIIII Irll lRiLJ UUUU 0 I.~ I~ '. ,
1:::}'C1IDg~~(== c. [~J ~l~f.~~~ ~~LJl.JW ~ n ~III ulJ I~I ~. 65'" i y, ~ _ . .::.:':..-.!'~::::::::::::::::'
I.' \'0:5R"1", ~~~g<X1<lBLsEilJillS OO[U.UL^~ri'f8A~Ill2CBII[Ei= 0 CJrnOJD ir n" - filE ~ ,IP- ....~.........
:' DDlt:R$T@~.=:Jq~B~BDD[DDIUi\r1nmD~llJJTII'l~rlll ~ ~ ~ v;r,:;.;......
:~ ~~~~~~~~~7JR~/~~DDm prJD Dnow~~ obbU~~~t lL ~~)... ....~~
,:n=c~]ECSmi2D!I1. ~ml' [fOrIf~nn;~ ~IID ODO~D~ cr]~~~~~~~6 i h='. ! ~~:...
"~P~~:~ "'~8 ~ ~;u .=!I t= [6JmWJ~ gggi~iDDr~~~ ul~ 111El"\i ~i'
~~;;-JIll:I[]IPIn1!: DO ~ -- w - ~L 'I' d=:5'/, =QC' - I ~n~ ~t
'i.i:.~";s;r.lr ,~fS...., : ~ '!ITlH ~~~ " ,\!; gEl I ~~1S.[: [~'~ UUUUl!!uDI"" .-
) ~--, c::C:j,=,,~:r'1 k' , ~ cI:!!K. li~ <::::; = ;tiCJ[RO.t-- ~~ Ih i
; f~r~'?J~~ I aaU~I~ /~II~ ~:~ ~ ~l!I,~~~~~@"~rS~~~ LJQ); C ~ ~L.
/~~ne.~.~~lB~g~~.:1 - ~ :~i'f~ ~~.U =gl~~~~-:~~~ 1~I~m~~ @II ~g ~. ~I~.... l-:-J:~':::;:~~
I(())j \ C'i\G3lo=d4= ~I rir!2lJuoonr,. ~~.I~'3tQ ~~NU~SERII~ 1-,l1Ol LllJ ~.!~-- .1?:.............'"
\.:;" I r- ll:~J"~ DDDtJuu~DDilll\~ ~I V!l:~O('~Ll:-'~ "~tilgJI,l ~\ I~.~ I ~ . I' .' I 1'"- .-- !
) BELLEl'IRJ~:~.} D[~ '11DDDrnQ~U~ ~ I (Ilj .~.i~t";.~~~kll~ F~i ,p].. ~", .....~~f: 01 ,'Writ ~~1~,.;r
.' ~)"{;ul \\\jS\/:~~".'':~(~WUUU,~~ ~llucrt ~I c:r ~I' Ilfl' "g IlUlf "f.> I I 115"
}J;~~2J~~gmll~Q.l>_ J~~[sl 1, ~DDDDDm .;:::. ~ .J~GO ~~,:, i\" !f\~ F'21-'U~~ C>;11= ')Jh -? ~~d"',
/(P!J;:~r;:;;/7~~ Ufln 1:=lfl nnr ~n~l,o-,:' I( ==::::51 '" ')1 -,If II '"" ) l'~=~)k T i (/<' ~ '.
Gulf
of
Mexico
~h
( '.1-)
, .
, : c:.
, .
I..
I .
,',
, .
. :r:
Ii'
l:~
I: \\
: \~.:
:~lr\
. L ..
',c.:.''>'1
:,r-r-. 1:
:'f ~:
I., .
. ro'
:~ :! Ii): :-:':',
:c w : :,: ~ ~
:~ ~ : :.:..: ~
.r>-. ~t,"..'
:J.q:: :r:~'~~
If!...J J, I_V' .'
t, ~ <:(. I (J) ,.' ., .
.~a. le,,'- 's.
:~<:: \z ,~~ II ~
'~~.,. . ..~ "",.
:1::3.1111 -, II '.... '..
I at': It. ~..:.:.'.
:cr...1 'tllt ~~~.
.-~-.~. ..~.-'"
BAYMON!'. :....,..,... !; II.
: ~-t'!': : '.~. '" ....,.. ~ .
1-, "'.._\l_~"~".'_
.- . I'..-t,.;~.......
: - : ~"".:tf'f<. ~" :.: ~
fJ:~~~.:..:::t ...H.f~;1 ~
.C\..-.. .. .. .. . . . " .
.,.....: I, -t,~....
: ( I!....l -s. :.t,o..
=(Jl .un..~ <S'1!~~
,\f; ..... "UCJ+'" 7<
II ~~ .........::.. ..",..
.... .... ...!.Jl.. .....:...
........ ... - :.- $? ....
-. ....
I\#tt . ..
\..~..[.......... .. Clearwater
',. /. Harbor
.. ~..
~_. ~
'~ ,
/(j\5 ....
, .
, .
, .'
. .
. ,
. .
. .
. ,
, .
. .
. .
, .
. .
. .
, .,
, ,
. ,
. 0,
. ,
. .
. "
. '4"
II ,.....
II ......
. ...
. ,
: ::....':
j' Il.' __"-:,'. -- (j
,. i !IIT'\:~'~'
\Jl
~
(/)
o
m
\Jl
7J
o
Gl
m
N
w4'
s
Scale: N.T.S,
\',
,I
Natural Gas
I nfrastructu re
Figure 15
Date: 5/1/2009
Source: Clearwater Gas System I Apr 2009
LeQend
[] LP Bulk Storage Tank (3ea)
- High Pressure Gas Line
... Gas Transmission Main
FEMA SFHA (Floodplain)
ZONE
~A
.AE
. AH (No Occurance within Clearwater)
.VE
D Ponds, Lakes, Rivers, Creeks
r::.: Clearwater Landmass
Outside Clearwater City Limits
II. i7"">.. Prepared by:
atel . t Engineering Department
Geographic Technology Division
~ _ earwa er 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is furnished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient wilh the
understanding that the data received was collected for Ihe purpose of
developing a graphic infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy,
completeness, reliabilily, or suitability of this data for any other particular
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.
City of Clearwater Floodpl~in Management Plan 2009
Gulf
of
Mexico
~
L '..
1 : (?:.
. .
'Ll
. .
. '.
. .
. .
.i'
i'l'
rj\.
: ~v .....
. '0. .>.
:,Ir,.,"1,:
:i~l~ ~.:
.~ .
:1'./:.... : :-:':',
:0 ~ J: :: ~ ~
.' :s .' '" .
:(q:-': :::-:.~~
. ~). . . II...
:,r S..J: :_ ':~ ~~ ~
.:t~JI 'U)\..~.,
:~ ~~: \~ '.~ ~~',
:~ ~-~: .~ ~~ ';' ~
::; ~~. ", \ :....,...
:~~: :::.-.::~~'.
.c.-.'" :~ ~.....
BAYMO~it'..... .... ..' ....
'--",,1 ....~......
,-.If"!'" 's ......
. ~. ... \ . .. . . ~ : ,
:=:;: -: ~.:..-~ ~{.::. ~:
: tl :.,"f<~~:::::
_._:_ :;~_: :'.', I, -.:!- fl......
. ~d.... .....:.:.... :. .'. r,',:
.~{O 'I ........: : : : : : :
. ~ ...... '..,' It. I"
. (0 ,...... .... ~~ I, . .
: )~ :...... .:...~o ...
. (c, .......... ~ ~ '.~
: \p .::-~::::._..: ~o.'~7< 0
.... .....<t~... .....
I, _-:" ::.."'.......
........:~.J..=::.-... itv
.. .... '2. .
''\- .... .
"_\ -.. ....
...~ ~.........." Clearwater
'. I : Harbor
\ ~Q:.'
: <<'9,",,:
. -.)" //..
:.0.:~.
: / ,,,.
. .
.~/
. ~.~.
.:t// :
. ..
. .
.:l~' .:
. ....
./'L..,.....
/11..........:.
.'..'" . .
:,,~-. .:.i~.__
//&~5
//a~~~-J,_
N
w-<?- E
S
Scale: N.T.S.
Public I Private
School Facilities
Figure 16
Date: 5/1/2009
Source: Clearwater Gas System I Apr 2009
Leaend
Public and Private Clearwater Schools
~ ACADEMY
.t SCHOOL
. COLLEGE/UNIVERSITY
.t OTHER
.t SPECIAL NEEDS
FEMA SFHA (Floodplain)
ZONE
j72JA
.AE
. AH (No Occurance within Clearwater)
.VE
G Ponds, Lakes, Rivers, Creeks
r::.: Clearwater Landmass
Outside Clearwater City Limits
II.. - Prepared by:
o~.Cl ~ t Engineering Department
Geographic Technology Division
~ _ ,garwa er 100 S. Myrtle Ave, Clearwater, FL 33766
U~ Ph: (727)662-4760, Fax: (727)626-4766
~ www.MyClearwater.com
Disclaimer:
Public information data is fumished by the City of Clearwater Engineering
Department, and must be accepted and used by the recipient with the
understanding that the data received was collected for the purpose of
developing a graphiC infrastructure inventory. As such, the City of Clearwater
makes no warranties, expressed or implied, concerning the accuracy.
completeness, reliability, or suitability of this data for any other partiCUlar
use. Furthermore, the City of Clearwater assumes no liability whatsoever
associated with the use or misuse of such data.