SGN2004-07009 (2)
SGN2004-07009
2436 GULF TO BAY BLVD
A]~V ANCE DISCOUNT AUTO PARr ~S
PLANNER OF RECORD: NOT ENTERED
ATLAS # 290B
ZONING: C
LAND USE: CG
RECEIVED: 07/13/2004
INCOMPLETE:
COMPLETE:
MAPS:
PHOTOS:
STAFF REPORT:
DRC:
CDB:
CLWCoverSheet
N
~l
.. ,
lB..'
JO' I
,
PLAT
(jj1n
~ U JIie Vl!;' Y
Ot3'CRhDnON
THE WEST 200 FEET OF THE EAST 776.7 FEET OF THE SOUTH JJO FEET OF THE SOUTHWEST QUARTER
(SW 1/4) OF THE NORTHEAST QUARTER (NE 1/4) OF SECTION 18, TOWNSHIP 29 SOUTH. RANGE 16
EAST. LESS EXISTING RIGHTS OF WAY, SITUATE: IN PINELUS COUNTY, FLORIDA.
CONTAINS 55945 SF OR 1.284 ACRES MORE OR LESS.
SHELLY STREET
(60' R/W) - f
2' CURB & GunER~
i>
.
.....
oj
S 89'57'26" E 200.03' MEAS
5 89.45'1Cf E 200.00' DESC
5' CW
:# ..-- 0.6' CONC CURB
T
flP-
Jp-
N 1.6' ~
'"
SIT 5/Ef' I.R.
~B 1<<75 ~
6' WF - r---:::-
-17.J' ':'
GRAPHIC SCALE
-
01 101 201 4cr 60'
t-~
I~
l'
20'
(
1fj
I f
I-- EIP
-
-
~
~
NOTES:
1. BEARING STRUCTURE BASED ON THE NORTH R/W LINE OF GULF TO BAY
BOULEVARD.
2. THIS SURVEY REFLECTS ONLY MATTERS OF RECORD AS PROVIDED BY THE
CLIENT OR CLIENTS REPRESENT A TlVE.
J. THIS SURVEY WAS MADE ON THE GROUND. THE UNDERGROUND UTILITIES
SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING
DRAWINGS. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND
UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA. EITHER IN
SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT
THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED
ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS
POSSIBLE FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY
LOCATED THE UNDERGROUND UTILITIES.
4. THIS SITE IS NOT IN A FLOOD PRONE AREA. IT IS IN ZONE X. AN AREA OF
MINIMAL FLOODING BASED ON FLOOD INSURANCE RATE MAP, PANEL NO. 125096
0128 G. HAVING AN EFFECTIVE DATE OF 9/3/200J. CITY OF CLEARWATER.
PINELLAS COUNTY. FLORIDA.
5. ACCORDING TO FLORIDA STATUTES. CHAPTER 472.025. A LAND SURVEYOR
SHALL NOT AFFIX HIS SEAL OR NAME TO ANY PLAN OR DRAWING WHICH
DEPICTS WORK WHICH HE IS NOT LICENSED TO PERFORM OR WHICH IS BEYOND
HIS PROFESSION OR SPECIALTY THEREIN. THEREFORE. WE ARE UNABLE TO
CERTIFY AS TO MUNICIPAL ZONING COMPLIANCE, INTERPRETATION OF ZONING
CODES OR THE DETERMINATION OF VIOLATIONS THEREOF.
6. THIS SURVEY MADE WITHOUT BENEFIT OF COMMITMENT FOR TITLE.
7. PER CITY OF CLEARWATER, ZONING DEPARTMENT THERE ARE NO CURRENTLY
REVISED BUILDING SETBACK LINES. THE EXISTING BUILDING IS GRANDFATHERED
IN AS TO WHERE IT EXISTS. ANY CHANGES TO THIS SITE WILL NEED TO BE
APPROVED BY SAID ZONING AUTHORITY.
~
~ ~ ~
:.: ~ ~
u 0
~ .
( 10 ~
.-s 0
~ ~ 1XI <:>
~ c:i
(.)
r,. ,.....
~ C\I
~~ lLJ
~
~Q::
..
0 ~
~~I
~ ~,
~
~
~
lB.J'
~
~
I-'~
1.2'
aw
;/CC(J/(/CI/f S(J!?fffS
THIS SURVEY MEETS THE "MINIMUM TECHNICAL
STANDARDS" AS REQUIRED BY CHAPTER 61 G 17 -6,
FLORIDA BOARD OF lAND SURVEYORS, PURSUANT TO
SECTION 472.027 OF THE FLORIDA STATUTES.
DATE: 7-z.-01
P//c()L
ROBERT c. JOHNSON PSM 5551
"NOT VALJD WfTHOUT THE SIGNATIJRE AND THE ORIGINAL RAISED
SEAL OF THIS FLORIDA LICENSED SURVEYOR AND MAPPER..
~
A. of ,O~lando Inc.., ,L!J. 4.475 1
2012 E. Robinson St.
Orlando, Florida 32803
PHONE FAX
407 894-6314 897-3777
0.6' CONC CURB
5 PS
7 PS
.I.
-
ASPHALT
CONC
DUMPSTER PAD
)L
~
~
LIFT
0.6' CONC CURB \
65.9' \
\,
1 PS
CONC
5 PS
-0.6' CONC CURB
E{P --1 __
& ~ J6.7' ___
...
.0
124.2'
(@
(ji
~
I"')
@~
C\j
ai....
1 STORY BLOCK
ADDRESS # 2436
I-
~
~
~ :.:<9
lICl ~ <i
01
..=
@
@
@
@
~tl @
I I ,/lU 124.2' sInn
CONC J
/ /
0- / /
ffPS / 6- V
L L
10'
Do
ASPHALT
1 0.6' CONC CURB
~
lJ PS
-f
iJl--- RAISED
~ SIGN
lEI! ,.S'!5' (' I')' yncnu~"t
~ 0.6' CONC CURB
190.00' D&M
I
-EIP
~
N B9.45'10~ W
,."
5' CW
ow ow ~
-0q
ow
CONC
APRON
ow
ow
ow
/
2' CURB & GUTTER~
~
~
f-
GULF TO BAY BOULEVARD
(100' R/W)
(S.R.
60)
...",- uP,
~C\
C'<
I
'(1.i'" - - t I
[IJ - E/P
lXl
.....
il)
I')
I")
4.8'
~..
C\j
..t
C\j
.....
ow
\,
(.)
~
o~
.. ~
0..
~~
O.
Q:)C
C"ID;)
~
~~
It ~
0_
0"
.. 0)
O)l()
It)c
· C
o
OV)
C/)
-"
I
v
I-t:>
:;;!~
~
~~
I
/
0.5' CONC CURB
.
L ~20.0~S~
f ;-..
oj
"'-- E/P
o
I<)
NOT PLAnED
VICINITY MAP
I
N. T. S.
10 FND. 4")(4" CM
cO NO I
~05~CONC CURB
~ 25.4'
'{6' WF
9.B'
5.9'
Do
t
E/P-
e.
(
~
:::>
(.)
u
. ~ ~
..... (.)
r-.: ~ rm
lXl
Or
!
~
~
....
'"
....
.~ - EIP
~~ - -0.5'1
EAS11000 DR
N
MASH ST
II\{
~ ~
~ ~
S i
~
SHWLY ST
SITE
1lIJII1U1lJan...
.
~
II
4111 ST
l!I
5TIlSl
z
..
!9
ORIGINAL
LEGEND
o - AJR RELEASE VALVE
~ - AUTO SPRINKLER
BB - BOTTOM OF BANK
BC - BACK OF CURB
.. - BACKFlOW PREVENTER
BLK - BLOCK
BM - BENCHMARK
@ - BOLlARD
BPC - BURIED POWER G.J.BLE
CALC - CALCULATED
CdeM - CALCULATED de MEASURED
A - CENTRAL ANGLE
CBW - CONCRETE BLOCK WALL
CC - COVERED CONCRETE
CF - CONCRETE flUME
CHW - CONCRETE HEAD WALL
CJ.{ - CHAIN liNK FENCE
f. - CENTERLINE
CM - CONCRETE MONUMENT
CMP - CORRUGATED METAL PIPE
CO - CLEAN OUT
CONC - CONCRETE
COVD - COVERED
CP - CONCRETE PAD
CW - CONCRITE WALKWAY
DdeM - DEED/DESC de MEASURED
DE - DRAINAGE EASEMENT
DESC - DESCRIPTION
~ - DDT INLIT
DP - DUMPSTER PAD
DW - DRIVEWAY
<lJP - ELECTRIC METER
EB - ELECTRICAL BOX
ESMT - EASEMENT
EIP - EDGE OF PAVEMENT
FIRM - flOOD INSURANCE
RATE MAP
FFE - FINISHED FLOOR ElEVA TION
FH - FIRE HYDRANT
FL - FLOW LINE
FND - FOUND
FOC - rlBER OPTIC CABLE
of? - FLAG POLE
-G- - GAS liNE
aID - GAS METER
>- - GUY WIRE ANCHOR
~ - HANDICAP PARKING
HR - HANDICAP RAMP
INV - INVERT ELEVATION
IP - IRON PIPE
IR - IRON ROD
QID - STORM JUNCTI' 'lOX
L - ARC LENGTH
~ - LIGHT POLE
LSA - LANDSCAPED AREA
MEAS - MEASURED
MF - METAL fENCE
MS - METAL SHED
~ - MITERED END ~'-~TlON
~ - MONITORING II
Nt!lD - NAIL t!l DISK
NGVD - NATIONAL GEODETIC
VERTICAL DATUM
NTS - NOT TO SCALE
OHE - OVERHEAD ElECTRIC
OL - ON LINE
ORB - OFFICIAL RECORDS BOOK
OW - OVERHEAD WIRE
OWK - OVERHEAD WALKWAY
PB - PLAT BOOK
PC - POINT OF CURVATURE
POOT - PER DEPARTMENT OF
TRANSPORTATION R/W MAP
PEP - PER ENGINEERING PLANS
PG - PAGE
PI - POINT OF INTERSECTION
PdeM - PLAT de MEASURED
POB - POINT OF BEGINNING
POC - POINT OF COMMENCEMENT
PP - POWER POLE
PS - PARKING SPACES
PT - POINT OF TANGENCY
PVC - PLASTIC PIPE
R - CURVE RADIUS
RCP - REINFORCED CONCRETE PIPE
R/W - RIGHT OF WAY
8) - SANITARY MANHOLE
SAN - SANITARY UNE
SN - SIGN
00.00 - SPOT ElEVATION
-SD- - STORM/DRAIN UNE
~ - STORM MANHOLE
-T- - UNDERGROUND TELEPHONE
[I] - STORM INLET
TB - TOP OF BANK
TP - TRAFFIC POLE
-"- - TRAFFIC SIGN
[I] - TRANSFORMER/JUNCTION BOX
TR - TElEPHONE RISER
TSB - TRAFFIC SIGNAL BOX
TSW - TRAFFIC SIGNAL WIRE
TV - CABLE TV RISER
TYP - TYPICAL
UE - UTILITY EASEMENT
UP - UTILITY POLE
-W- - WATER LINE
WF - WOOD FENCE
WS - WOOD SHED
-0- - WATER METER
... - WATER VALVE
# - NUMBER
(j) - EASEMENT NUMBER
I . LINE CHART
~- N 44.23'05" W 14.05' D&M
SE CORNER
PARCEL 1
18-29-16-00)00-130-0800
FND. S/Ef' IR
NO I
.320.06' MEAS_ ~
o
ll)
9M 2CO~ -bl7COC}
Current BOUNDARY SURVEY DA TE:
per Florida Statutes 61 G 1 7- 6. 003 2d
OA TE: REVISION
6-22-04
BY:
SIT 51Ef' I.R.
~' LB 14475
...
<7 ~ ~
" ")C. 1)..' 0
Q~;-..\:)q I
aw .
~ 01 'Ie\.
','
I-
I: ,
, ,
, - ,
BOUNlJARY &- LOCATION SURVEY
i -:-.
ir.~:
! .
C~ #16-29-18-AAP
APPROVED BY:
DRAWN BY: ML oeM
SCALE: 1"= 20'
FIELD DATE: 6-22-04
PREPARED FOR:
INTERPLAN, LLP
, .
LOCATION: 2436 GULF TO BAY BOULEVARD.
CLEARWATER, PINEL LAS COUNTY. FLORIDA
FILE NUUBER:
18-29-16
~~ 3(.p Qu\fto'Oo.y~\vc!