Loading...
SGN2004-07009 (2) SGN2004-07009 2436 GULF TO BAY BLVD A]~V ANCE DISCOUNT AUTO PARr ~S PLANNER OF RECORD: NOT ENTERED ATLAS # 290B ZONING: C LAND USE: CG RECEIVED: 07/13/2004 INCOMPLETE: COMPLETE: MAPS: PHOTOS: STAFF REPORT: DRC: CDB: CLWCoverSheet N ~l .. , lB..' JO' I , PLAT (jj1n ~ U JIie Vl!;' Y Ot3'CRhDnON THE WEST 200 FEET OF THE EAST 776.7 FEET OF THE SOUTH JJO FEET OF THE SOUTHWEST QUARTER (SW 1/4) OF THE NORTHEAST QUARTER (NE 1/4) OF SECTION 18, TOWNSHIP 29 SOUTH. RANGE 16 EAST. LESS EXISTING RIGHTS OF WAY, SITUATE: IN PINELUS COUNTY, FLORIDA. CONTAINS 55945 SF OR 1.284 ACRES MORE OR LESS. SHELLY STREET (60' R/W) - f 2' CURB & GunER~ i> . ..... oj S 89'57'26" E 200.03' MEAS 5 89.45'1Cf E 200.00' DESC 5' CW :# ..-- 0.6' CONC CURB T flP- Jp- N 1.6' ~ '" SIT 5/Ef' I.R. ~B 1<<75 ~ 6' WF - r---:::- -17.J' ':' GRAPHIC SCALE - 01 101 201 4cr 60' t-~ I~ l' 20' ( 1fj I f I-- EIP - - ~ ~ NOTES: 1. BEARING STRUCTURE BASED ON THE NORTH R/W LINE OF GULF TO BAY BOULEVARD. 2. THIS SURVEY REFLECTS ONLY MATTERS OF RECORD AS PROVIDED BY THE CLIENT OR CLIENTS REPRESENT A TlVE. J. THIS SURVEY WAS MADE ON THE GROUND. THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA. EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 4. THIS SITE IS NOT IN A FLOOD PRONE AREA. IT IS IN ZONE X. AN AREA OF MINIMAL FLOODING BASED ON FLOOD INSURANCE RATE MAP, PANEL NO. 125096 0128 G. HAVING AN EFFECTIVE DATE OF 9/3/200J. CITY OF CLEARWATER. PINELLAS COUNTY. FLORIDA. 5. ACCORDING TO FLORIDA STATUTES. CHAPTER 472.025. A LAND SURVEYOR SHALL NOT AFFIX HIS SEAL OR NAME TO ANY PLAN OR DRAWING WHICH DEPICTS WORK WHICH HE IS NOT LICENSED TO PERFORM OR WHICH IS BEYOND HIS PROFESSION OR SPECIALTY THEREIN. THEREFORE. WE ARE UNABLE TO CERTIFY AS TO MUNICIPAL ZONING COMPLIANCE, INTERPRETATION OF ZONING CODES OR THE DETERMINATION OF VIOLATIONS THEREOF. 6. THIS SURVEY MADE WITHOUT BENEFIT OF COMMITMENT FOR TITLE. 7. PER CITY OF CLEARWATER, ZONING DEPARTMENT THERE ARE NO CURRENTLY REVISED BUILDING SETBACK LINES. THE EXISTING BUILDING IS GRANDFATHERED IN AS TO WHERE IT EXISTS. ANY CHANGES TO THIS SITE WILL NEED TO BE APPROVED BY SAID ZONING AUTHORITY. ~ ~ ~ ~ :.: ~ ~ u 0 ~ . ( 10 ~ .-s 0 ~ ~ 1XI <:> ~ c:i (.) r,. ,..... ~ C\I ~~ lLJ ~ ~Q:: .. 0 ~ ~~I ~ ~, ~ ~ ~ lB.J' ~ ~ I-'~ 1.2' aw ;/CC(J/(/CI/f S(J!?fffS THIS SURVEY MEETS THE "MINIMUM TECHNICAL STANDARDS" AS REQUIRED BY CHAPTER 61 G 17 -6, FLORIDA BOARD OF lAND SURVEYORS, PURSUANT TO SECTION 472.027 OF THE FLORIDA STATUTES. DATE: 7-z.-01 P//c()L ROBERT c. JOHNSON PSM 5551 "NOT VALJD WfTHOUT THE SIGNATIJRE AND THE ORIGINAL RAISED SEAL OF THIS FLORIDA LICENSED SURVEYOR AND MAPPER.. ~ A. of ,O~lando Inc.., ,L!J. 4.475 1 2012 E. Robinson St. Orlando, Florida 32803 PHONE FAX 407 894-6314 897-3777 0.6' CONC CURB 5 PS 7 PS .I. - ASPHALT CONC DUMPSTER PAD )L ~ ~ LIFT 0.6' CONC CURB \ 65.9' \ \, 1 PS CONC 5 PS -0.6' CONC CURB E{P --1 __ & ~ J6.7' ___ ... .0 124.2' (@ (ji ~ I"') @~ C\j ai.... 1 STORY BLOCK ADDRESS # 2436 I- ~ ~ ~ :.:<9 lICl ~ <i 01 ..= @ @ @ @ ~tl @ I I ,/lU 124.2' sInn CONC J / / 0- / / ffPS / 6- V L L 10' Do ASPHALT 1 0.6' CONC CURB ~ lJ PS -f iJl--- RAISED ~ SIGN lEI! ,.S'!5' (' I')' yncnu~"t ~ 0.6' CONC CURB 190.00' D&M I -EIP ~ N B9.45'10~ W ,." 5' CW ow ow ~ -0q ow CONC APRON ow ow ow / 2' CURB & GUTTER~ ~ ~ f- GULF TO BAY BOULEVARD (100' R/W) (S.R. 60) ...",- uP, ~C\ C'< I '(1.i'" - - t I [IJ - E/P lXl ..... il) I') I") 4.8' ~.. C\j ..t C\j ..... ow \, (.) ~ o~ .. ~ 0.. ~~ O. Q:)C C"ID;) ~ ~~ It ~ 0_ 0" .. 0) O)l() It)c · C o OV) C/) -" I v I-t:> :;;!~ ~ ~~ I / 0.5' CONC CURB . L ~20.0~S~ f ;-.. oj "'-- E/P o I<) NOT PLAnED VICINITY MAP I N. T. S. 10 FND. 4")(4" CM cO NO I ~05~CONC CURB ~ 25.4' '{6' WF 9.B' 5.9' Do t E/P- e. ( ~ :::> (.) u . ~ ~ ..... (.) r-.: ~ rm lXl Or ! ~ ~ .... '" .... .~ - EIP ~~ - -0.5'1 EAS11000 DR N MASH ST II\{ ~ ~ ~ ~ S i ~ SHWLY ST SITE 1lIJII1U1lJan... . ~ II 4111 ST l!I 5TIlSl z .. !9 ORIGINAL LEGEND o - AJR RELEASE VALVE ~ - AUTO SPRINKLER BB - BOTTOM OF BANK BC - BACK OF CURB .. - BACKFlOW PREVENTER BLK - BLOCK BM - BENCHMARK @ - BOLlARD BPC - BURIED POWER G.J.BLE CALC - CALCULATED CdeM - CALCULATED de MEASURED A - CENTRAL ANGLE CBW - CONCRETE BLOCK WALL CC - COVERED CONCRETE CF - CONCRETE flUME CHW - CONCRETE HEAD WALL CJ.{ - CHAIN liNK FENCE f. - CENTERLINE CM - CONCRETE MONUMENT CMP - CORRUGATED METAL PIPE CO - CLEAN OUT CONC - CONCRETE COVD - COVERED CP - CONCRETE PAD CW - CONCRITE WALKWAY DdeM - DEED/DESC de MEASURED DE - DRAINAGE EASEMENT DESC - DESCRIPTION ~ - DDT INLIT DP - DUMPSTER PAD DW - DRIVEWAY <lJP - ELECTRIC METER EB - ELECTRICAL BOX ESMT - EASEMENT EIP - EDGE OF PAVEMENT FIRM - flOOD INSURANCE RATE MAP FFE - FINISHED FLOOR ElEVA TION FH - FIRE HYDRANT FL - FLOW LINE FND - FOUND FOC - rlBER OPTIC CABLE of? - FLAG POLE -G- - GAS liNE aID - GAS METER >- - GUY WIRE ANCHOR ~ - HANDICAP PARKING HR - HANDICAP RAMP INV - INVERT ELEVATION IP - IRON PIPE IR - IRON ROD QID - STORM JUNCTI' 'lOX L - ARC LENGTH ~ - LIGHT POLE LSA - LANDSCAPED AREA MEAS - MEASURED MF - METAL fENCE MS - METAL SHED ~ - MITERED END ~'-~TlON ~ - MONITORING II Nt!lD - NAIL t!l DISK NGVD - NATIONAL GEODETIC VERTICAL DATUM NTS - NOT TO SCALE OHE - OVERHEAD ElECTRIC OL - ON LINE ORB - OFFICIAL RECORDS BOOK OW - OVERHEAD WIRE OWK - OVERHEAD WALKWAY PB - PLAT BOOK PC - POINT OF CURVATURE POOT - PER DEPARTMENT OF TRANSPORTATION R/W MAP PEP - PER ENGINEERING PLANS PG - PAGE PI - POINT OF INTERSECTION PdeM - PLAT de MEASURED POB - POINT OF BEGINNING POC - POINT OF COMMENCEMENT PP - POWER POLE PS - PARKING SPACES PT - POINT OF TANGENCY PVC - PLASTIC PIPE R - CURVE RADIUS RCP - REINFORCED CONCRETE PIPE R/W - RIGHT OF WAY 8) - SANITARY MANHOLE SAN - SANITARY UNE SN - SIGN 00.00 - SPOT ElEVATION -SD- - STORM/DRAIN UNE ~ - STORM MANHOLE -T- - UNDERGROUND TELEPHONE [I] - STORM INLET TB - TOP OF BANK TP - TRAFFIC POLE -"- - TRAFFIC SIGN [I] - TRANSFORMER/JUNCTION BOX TR - TElEPHONE RISER TSB - TRAFFIC SIGNAL BOX TSW - TRAFFIC SIGNAL WIRE TV - CABLE TV RISER TYP - TYPICAL UE - UTILITY EASEMENT UP - UTILITY POLE -W- - WATER LINE WF - WOOD FENCE WS - WOOD SHED -0- - WATER METER ... - WATER VALVE # - NUMBER (j) - EASEMENT NUMBER I . LINE CHART ~- N 44.23'05" W 14.05' D&M SE CORNER PARCEL 1 18-29-16-00)00-130-0800 FND. S/Ef' IR NO I .320.06' MEAS_ ~ o ll) 9M 2CO~ -bl7COC} Current BOUNDARY SURVEY DA TE: per Florida Statutes 61 G 1 7- 6. 003 2d OA TE: REVISION 6-22-04 BY: SIT 51Ef' I.R. ~' LB 14475 ... <7 ~ ~ " ")C. 1)..' 0 Q~;-..\:)q I aw . ~ 01 'Ie\. ',' I- I: , , , , - , BOUNlJARY &- LOCATION SURVEY i -:-. ir.~: ! . C~ #16-29-18-AAP APPROVED BY: DRAWN BY: ML oeM SCALE: 1"= 20' FIELD DATE: 6-22-04 PREPARED FOR: INTERPLAN, LLP , . LOCATION: 2436 GULF TO BAY BOULEVARD. CLEARWATER, PINEL LAS COUNTY. FLORIDA FILE NUUBER: 18-29-16 ~~ 3(.p Qu\fto'Oo.y~\vc!