03-19
RESOLUTION NO. 03-19
A RESOLUTION OF THE CITY OF CLEARWATER, FLORIDA,
AUTHORIZING THE EXECUTION OF PIPELINE AND WIRELlNE
CROSSING AGREEMENTS BETWEEN THE CITY OF CLEARWATER
AND CSX TRANSPORTATION, INC., FOR THE INSTALLATION OF
ONE (1) 16" RECLAIMED WATER MAIN WITHIN CSX RIGHT-OF-
WAY, PROVIDING AN EFFECTIVE DATE.
WHEREAS, the City authorizes the execution of Pipeline Crossing
Agreement No. CSX-044933 and agrees to the terms and conditions of the agreement,
copies of which are attached hereto, and
WHEREAS, CSX Transportation Inc. has agreed to allow the City to install
one (1) 16" reclaimed water main in a 30" steel casing at Jeffords Street within their right-of-
way, as stated within the terms of said agreement, and
WHEREAS, the City Manager of the City of Clearwater is hereby authorized
to sign the agreement described in this resolution.
BE IT RESOLVED BY THE CITY COMMISSION OF THE
CITY OF CLEARWATER, FLORIDA:
Section 1. The City Commission hereby accepts and approves the Pipeline
Crossing Agreements between the City of Clearwater and CSX Transportation, Inc.,
allowing the City to install one (1) 16" reclaimed water main within CSX right-of-way.
Section 2. This resolution shall take effect immediately upon adoption.
PASSED AND ADOPTED this
3r:rial1~~
Mayor-Commissioner
Cynthia E. Goudeau
City Clerk
Resolution No. 03-19
AGREEMENT CHECKLIST
Agreement Number: CSX-044933
Please perform the following when executing the attached instrument:
X Sign the signature page in order to execute the agreement. One of the following should apply:
Execution on behalf of a CORPORATION should be accomplished by the President, Vice President or an officer
authorized by Board Resolution to execute legal documents on behalf of the Corporation. (Copy of Board Authorization
should be furnished for anyone signing, other than the President or Vice President.) If the Corporate name is set out
erroneously in the Agreement, the document should be executed and the name corrected and initialed where it appears.
(Municipal Corporation, furnish copy of such Resolution.)
If Agreement is with an INDIVIDUAL, that individual should sign the Agreement exactly as the name is set out in the
caption of the Agreement. If the name is set out erroneously in the Agreement, the document should be executed and
the name corrected and initialed where it appears.
If the Agreement is with a PARTNERSHIP, all general members of the partnership should execute the docum ent unless
one member of the firm has been designated managing partner or expressly by the partnership to execute the
Agreement. (Furnish copy of such authority.)
X The signature(s) must be WITNESSED by ONE (1) witness in the space(s) provided.
X NAME(S) and TITLE(S) of person(s) executing the agreement must be typed or printed in ink directly beneath
signature(s).
X Social Security Number is required if Agreement is with an INDIVIDUAL, if Agreement is with other than an
INDIVIDUAL, a Tax Identification Number is required.
X Furnish Certificate of Insurance which states "CSX Transportation, Inc. as additional insured," which is required
under the INSURANCE Article, to Speed Code J180, 500 Water Street, Jacksonville, FL 32202. Questions regarding
the insurance requirements should be directed to CSXTs Mr. W. D. Tyler, Manager Risk Management (904) 633-5090.
X Initial and date each rider attached to the document following the signature page.
X In returning the Agreement, please furnish the following fee(s) set out in the Article(s) described within the Agreement:
One-time Encroachment Inventory Fee (refer to FEE's Article)
$300.00
$750.00
$1,050.00
Construction Risk Fee (refer to INSURANCE Article)
TOTAL DUE
CSXT Form 2037G - Page 1
Revised May 2002 0
Agreement No. CSX-044933
PIPELINE CROSSING AGREEMENT
THIS AGREEMENT, Made as of February 19,2003, by and between CSX
TRANSPORTATION, INC., a Virginia corporation, whose mailing address is 500 Water Street,
Jacksonville, Florida 32202, hereinafter called "Licensor," and CITY OF CLEARWATER
PUBLIC UTILITIES DEPARTMENT, a municipal corporation, political subdivision or state
agency, under the laws of the State of Florida, whose mailing address is 100 South Myrtle
Avenue, Clearwater, Florida 33756, hereinafter called "Licensee," WITNESSETH:
WHEREAS, Licensee desires to construct, use and maintain a pipeline, solely for the
transmission of reclaimed water, hereinafter called "Pipeline," under or across the track(s) and
property owned or controlled by Licensor at or near Clearwater, County of Pinellas, State of
Florida, located at Valuation Station 1414+26, Milepost SY-875.45, Clearwater Subdivision,
hereinafter called the "Crossing," as shown on print of Licensee's Drawing JL044933, dated
December 31, 2002, attached hereto and made a part hereof; other details and data pertaining to
said Pipeline being as indicated on Licensee's Application Form, dated February 17,2003, also
attached hereto and made a part hereof;
NOW, THEREFORE, in consideration of the mutual covenants, conditions, terms and
agreements herein contained, the parties hereto agree and covenant as follows:
1. LICENSE:
1.1 Subject to Article 17, Licensor, insofar as it has the legal right, power and authority
to do so, and its present title permits, and subject to:
(A) Licensor's present and future right to occupy, possess and use its property
within the area of the Crossing for any and all purposes;
(B) All encumbrances, conditions, covenants, easements, and limitations
applicable to Licensor's title to or rights in the subject property; and
(C) Compliance by Licensee with the terms and conditions herein contained;
does hereby license and permit Licensee to construct, maintain, repair, renew, operate, use, alter or
change said Pipeline at the Crossing above for the term herein stated, and to remove same upon
termination.
1.2 The term Pipeline, as used herein, shall include only the pipes, ducts, casing, vents,
manholes, connectors, fixtures, appliances and ancillary facilities devoted exclusively to the
transmission usage above within the Crossing, and as shown on attached Application Form.
1.3 No additional pipeline or other facilities shall be placed, allowed or maintained by
Licensee in, upon or along the Crossing except upon separate prior written consent of Licensor.
CSXT Form 2037G - Page 2
Revised May 2002 '"
Agreement No. CSX-044933
2. ENCROACHMENT INVENTORY FEE:
2.1 In lieu of annual payments and in consideration of Licensor's waiver of future fee
increases, Licensee shall pay Licensor a one-time nonrefundable Encroachment Inventory Fee of
THREE HUNDRED AND 00/100 U.S. DOLLARS ($300.00) upon execution of this Agreement.
Licensee agrees that the License Fee applies only to the original Licensee under this Agreement.
In the event of a successor (by merger, consolidation, reorganization and/or assignment) or if the
original Licensee changes its name, then Licensee shall be subject to payment of Licensor's
current administrative and document preparation fees for the cost incurred by Licensor in
preparing and maintaining this Agreement on a current basis.
2.2 However, Licensee assumes sole responsibility for, and shall pay directly(or
reimburse Licensor), any additional annual taxes and/or periodic assessments levied against
Licensor or Licensor's property solely on account of said Pipeline or Crossing.
2.3 This Agreement shall be effective upon the date first written above. License shall
be revocable only, as herein provided, but shall also terminate upon (a) Licensee's cessation of use
of the Pipeline or Crossing for the purpose(s) above, (b) removal of the Pipeline, and/or
(c) subsequent mutual consent.
2.4 In further consideration for the license or right hereby granted, Licensee hereby
agrees that Licensor shall not be charged or assessed, directly or indirectly, with any part of the
cost of the installation of said Pipeline and appurtenances, and/or maintenance thereof, or for any
public works project of which said Pipeline is a part.
3. CONSTRUCTION, MAINTENANCE AND REPAIRS:
3.1 Licensee shall construct, maintain, relocate, repair, renew, alter, and/or remove said
Pipeline, in a prudent, workmanlike manner, using quality materials and complying with: any
applicable standard(s) or regulation(s) of Licensor (A.R.E.M.A. Specifications) and Licensee's
particular industry, and/or any governmental or regulatory body having jurisdiction over the
Crossing or Pipeline.
3.2 Location and construction of Pipeline shall be made strictly in accordance with
design( s) and specifications furnished to and approved by Licensor, and of material( s) and size( s)
appropriate for the purpose( s) above recited.
3.3 All Licensee's work and exercise of rights hereunder shall be undertaken at time(s)
satisfactory to Licensor and so as to eliminate or minimize any impact on or interference with the
safe use and operation of Licensor's track(s).
CSXT Form 2037G - Page 3
Revised May 2002 0
Agreement No. CSX-044933
3.4 In the installation, maintenance, repair and/or removal of said Pipeline, Licensee
shall not use explosives of any type or perform or cause any blasting without the separate express
written consent of Licensor. As a condition to such consent, a representative will be assigned by
Licensor to monitor blasting, and Licensee shall reimburse Licensor for the entire cost and/or
expense of furnishing said monitor.
3.5 Any repairs or maintenance to Pipeline, whether resulting from acts of Licensee, or
natural or weather events, which are necessary to protect or facilitate Licensor's use of its property,
shall be made by Licensee promptly, but in no event later than thirty (30) days after Licensee has
notice as to the need for such repairs or maintenance.
3.6 Licensor, in order to protect or safeguard its property, rail operations, equipment
and/or employees from damage or injury, may request immediate repair or renewal of the Pipeline,
and if the same is not performed, may make or contract to make such repairs or renewals, at the
sole risk, cost and expense of Licensee.
3.7 Neither the failure of Licensor to object to any work done, material used, or method
of construction or maintenance of said Crossing, nor any approval given or supervision exercised
by Licensor, shall be construed as an admission ofliability or responsibility by Licensor, or as a
waiver by Licensor of any of the obligations, liability and/or responsibility of Licensee under this
Agreement.
3.8 Licensee hereby agrees to reimburse Licensor any loss, cost or expense (including
losses resulting from train delays and/or inability to meet train schedules) arising from any failure
of Licensee to make repairs or conduct maintenance as required by Section 3.5 above or from
improper or incomplete repairs or maintenance to Pipeline.
4. PERMITS, LICENSES:
4.1 Before any work hereunder is performed, or before use of the Crossing for the
contracted purpose, Licensee, at its sole cost and expense, shall obtain all necessary permit(s)
(including but not limited to zoning, building, construction, health, safety or environmental
matters), letter(s) or certificate(s) of approval. Licensee expressly agrees and warrants that it shall
conform and limit its activities to the terms of such permit(s), approval(s) and authorization(s), and
shall comply with all applicable ordinances, rules, regulations, requirements and laws of any
governmental authority (state, federal or local) having jurisdiction over Licensee's activities,
including the location, contact, excavation and protection regulations of the Occupational Safety
and Health Act (OSHA) (20 CFR 1926.651(b), et al.), and State "One Call" - "Call Before You
Dig" requirements.
4.2 Licensee assumes sole responsibility for failure to obtain such permit(s) or
approval(s), for any violations thereof, or for costs or expenses of compliance or remedy.
CSXT Form 2037G - Page 4
Revised May 2002 '"
Agreement No. CSX-044933
5. MARKING AND SUPPORT:
5.1 With respect to any subsurface installation or maintenance upon Licensor's
property, Licensee, at its sole cost and expense, shall:
(A) Support track(s) and roadbed of Licensor, in a manner satisfactory to
Licensor;
(B) Backfill with satisfactory material and thoroughly tamp all trenches to
prevent settling of surface of land and roadbed of Licensor; and
(C) Either remove any surplus earth or material from Licensor's property or
cause said surplus earth or material to be placed and distributed at location(s) and in such manner
as Licensor may approve.
5.2 After construction or maintenance of Pipeline, Licensee shall:
(A) Restore said track(s), roadbed and other disturbed property of Licensor; and
(B) Erect, maintain and periodically verify the accuracy of aboveground
markers, in a form approved by Licensor, indicating the location, depth and ownership of Pipeline
or related facilities.
5.3 Licensee shall remain responsible for any settlement ofthe track(s) or roadbed for a
period of one (1) year subsequent to completion of installation.
6. TRACK CHANGES:
6.1 In the event that Licensor's rail operations and/or track maintenance result in
changes in grade or alignment of, additions to, or relocation of Licensor's track(s) or other
facilities, or in the event future use by Licensor of right-of-way and property necessitate any
change oflocation, height or depth of Pipeline or Crossing, Licensee, at its sole cost and expense
and within thirty (30) days after notice in writing from Licensor, shall make changes in Pipeline or
Crossing to accommodate Licensor's track(s) or operations.
6.2 If Licensee fails to do so, Licensor may make or contract to make such changes at
Licensee's cost.
7. PIPE CHANGES:
7.1 Licensee shall periodically monitor and verify the depth or height of Pipeline and
Crossing in relation to Licensor's tracks and facilities, and shall relocate Pipeline or change
Crossing, at Licensee's expense, should such relocation or change be necessary to comply with the
minimum clearance requirements of this Agreement or of any public authority.
CSXT Form 2037G - Page 5
Revised May 2002 0
Agreement No. CSX-044933
7.2 If Licensee undertakes to revise, renew, relocate or change all or any part of
Pipeline (including any change in circumference, diameter or radius of pipe or carrier pipe, change
in operating pressure, or change in materials transmitted in and through said pipe), or is required by
any public agency or court order to do so, plans therefor shall be submitted to Licensor for
approval before any such change is made. After approval the terms and conditions of this
Agreement shall apply thereto.
8. INTERFERENCE WITH RAIL FACILITIES:
8.1 Although the Pipeline/Crossing herein permitted may not presently interfere with
Licensor's railroad operations or facilities, in the event that the operation, existence or maintenance
of said Pipeline, in the sole judgment of Licensor, causes: (a) interference (physical, magnetic or
otherwise) with Licensor's communication, signal or other wires, powerlines, train control system,
or facilities; or (b) interference in any manner with the operation, maintenance or use by Licensor
of its right-of-way, track(s), structures, pole line(s), devices, other property, or any appurtenances
thereto; then and in either event, Licensee, upon receipt of written notice from Licensor of any
such interference, and at Licensee's sole risk, cost and expense, shall promptly take such remedial
action or make such changes in its Pipeline as may be required in the reasonable judgment of
Licensor to eliminate all such interference. Upon Licensee's failure to remedy or change, Licensor
may do so or contract to do so, at Licensee's sole cost.
8.2 Without assuming any duty hereunder to inspect Licensee's Pipeline, Licensor
hereby reserves the right to inspect same and to require Licensee to undertake necessary repairs,
maintenance or adjustments to Pipeline, which Licensee hereby agrees to make promptly, at
Licensee's sole cost and expense.
9. RISK, LIABILITY, INDEMNITY:
With respect to the relative risk and liabilities of the parties, it is hereby agreed that:
9.1 Licensee hereby assumes, and, to the fullest extent permitted by State law
(Constitutional or Statutory, as amended), shall defend, indemnify, and hold Licensor harmless
from and against any and all liability , loss, claim, suit, damage, charge or expense which Licensor
may suffer, sustain, incur or in any way be subjected to, on account of death of or injury to any
person whomsoever (including officers, agents, employees or invitees of Licensor), and for
damage to or loss of or destruction of any property whatsoever, arising out of, resulting from, or in
any way connected with the construction, presence, existence, repair, maintenance, replacement,
operations, use or removal of Pipeline or any structure in connection therewith, or restoration of
premises of Licensor to good order or condition after removal, EXCEPT when caused solely by the
willful misconduct or gross negligence of Licensor. HOWEVER, during any period of actual
construction, repair, maintenance, replacement or removal of pipeline, wherein agents, equipment
or personnel of Licensee are on the railroad right-of-way, Licensee's liability hereunder shall be
absolute, irrespective of any joint, sole or contributory fault or negligence of Licensor.
CSXT Form 2037G - Page 6
Revised May 2002 ""
Agreement No. CSX-044933
9.2 Use of Licensor's right-of-way involves certain risks ofloss or damage as a result of
Licensor's rail operations. Notwithstanding Section 9.1, Licensee expressly assumes all risk of loss
and damage to Licensee's Property or Pipeline in, on, over or under the Occupancy, including loss
of or any interference with use thereof, regardless of cause, including electrical field creation, fire
or derailment arising out of Licensor's rail operations. For this Section, the term "Licensee's
Property" shall include pipe contents as well as property of third parties situated or placed upon
Licensor's right-of-way by Licensee or by such third parties at request of or for benefit of Licensee.
9.3 To the extent permitted by State law, as above, Licensee assumes all responsibility
for, and agrees to defend, indemnify and hold Licensor harmless from: (a) all claims, costs and
expenses, including reasonable attorneys' fees, as a consequence of any sudden or nonsudden
pollution of air, water, land and/or ground water on or off the Crossing area, arising from or in
connection with the use of this Crossing or resulting from leaking, bursting, spilling, or any escape
of the material transmitted in or through said Pipeline; (b) any claim or liability arising under
federal or state law dealing with either such sudden or nonsudden pollution of air, water, land
and/or ground water arising therefrom or the remedy thereof; and (c) any subsidence or failure of
lateral or subjacent support of Licensor's tracks arising from such Pipeline leakage.
9.4 Obligations of Licensee hereunder to defend, indemnify and hold Licensor
harmless shall also extend to companies and other legal entities that control, are controlled by,
subsidiaries of, or are affiliated with Licensor, and their respective officers, agents and employees.
9.5 If a claim is made or action is brought against either party, for which the other party
may be responsible hereunder, in whole or in part, such other party shall be notified and permitted
to participate in the handling or defense of such claim or action.
10. INSURANCE:
10.1 Prior to commencement of surveys, construction or occupation of Crossing
pursuant to this Agreement, Licensee shall procure, and shall maintain during the continuance of
this Agreement, at Licensee's sole cost and expense, a policy of Commercial General Liability
Insurance (CGL), naming Licensor as additional insured and covering liability assumed by
Licensee under this Agreement. A coverage limit of not less than THREE MILLION AND 00/100
U.S. DOLLARS ($3,000,000.00) Combined Single Limit per occurrence for bodily injury liability
and property damage liability is currently required as a prudent minimum to protect Licensee's
assumed obligations. The evidence of insurance coverage shall be endorsed to provide for thirty
(30) days' notice to Licensor prior to cancellation or modification of any policy. Mail CGL
certificate, along with agreement, to CSX Transportation, Inc., Speed Code 1180,500 Water Street,
Jacksonville, FL 32202. On each successive year, send certificate to Speed Code J907 at the
address listed above.
CSXT Form 2037G - Page 7
Revised May 2002 0
Agreement No. CSX-044933
10.2 If said CGL policy does not automatically cover Licensee's contractual liability
during periods of survey, construction, maintenance and continued occupation, a specific
endorsement adding such coverage shall be purchased by Licensee. If said CGL policy is written
on a "claims made" basis instead of a "per occurrence" basis, Licensee shall arrange for adequate
time for reporting losses. Failure to do so shall be at Licensee's sole risk.
10.3 Notwithstanding the provisions of Sections 10.1 and 10.2, Licensee, pursuant to
State Statute(s), may self-insure or self-assume, in any amount(s), any contracted liability arising
under this Agreement, under a funded program of self-insurance, which fund will respond to
liability of Licensee imposed by and in accordance with the procedures established by law.
10.4 Securing such insurance shall not limit Licensee's liability under this Agreement,
but shall be additional security therefor.
10.5 Specifically to cover construction and/or demolition activities within fifty feet (50') of
any operated railroad track(s) or affecting any railroad bridge, trestle, tunnel, track(s), roadbed,
overpass or underpass, Licensee shall pay to Licensor the sum of SEVEN HUNDRED FIFTY AND
00/100 U.S. DOLLARS ($750.00), to cover the cost of adding this Crossing to Licensor's Railroad
Protective Liability (RPL) Policy for the period of actual construction.
11. GRADE CROSSINGS; FLAGGING:
11.1 Nothing herein contained shall be construed to permit Licensee, or any contractor
of Licensee, to move any vehicles or equipment over track(s) of Licensor, except at public road
crossing(s), without separate prior written approval of Licensor (CSXT Form 7422).
11.2 If Licensor deems it advisable, during the progress of any construction,
maintenance, repair, renewal, alteration, change or removal of said Pipeline, to place watchmen,
flagmen, inspectors or supervisors at the Crossing for protection of operations of Licensor or others
on Licensor's right-of-way, and to keep persons, equipment and materials away from Licensor's
track(s), Licensor shall have the right to do so at the expense of Licensee, but Licensor shall not be
liable for failure to do so.
11.3 Subject to Licensor's consent and to Licensor's Railroad Operating Rules and
existing labor agreements, Licensee may provide such flagmen, watchmen, inspectors or
supervisors, during all times of construction, repair, maintenance, replacement or removal, at
Licensee's sole risk and expense; and in such event, Licensor shall not be liable for the failure or
neglect of such watchmen, flagmen, inspectors or supervisors.
12. LICENSOR'S COSTS:
12.1 Any additional or alternative costs or expenses incurred by Licensor to
accommodate Licensee's continued use of Licensor's property as a result of track changes or pipe
changes shall also be paid by Licensee.
CSXT Form 2037G - Page 8
Revised May 2002 0
Agreement No. CSX-044933
12.2 Licensor's expense for wages ("force account" work) and materials for any work
performed at the expense of Licensee pursuant hereto shall be paid by Licensee within thirty (30)
days after receipt of Licensor's bill therefor, subject to Licensee's budgetary rules.
12.3 Such expense shall include, but not be limited to, cost of railroad labor and
supervision under "force account" rules, plus current applicable overhead percentages, the actual
cost of materials, and insurance, freight and handling charges on all materials used. Equipment
rentals shall be in accordance with Licensor's applicable fixed rate(s).
12.4 If any amount due pursuant to the terms of this Agreement is not paid by the due
date, it will be subject to Licensor's standard late charge and will also accrue interest at eighteen
percent (18%) per annum, unless limited by local law, and then at the highest rate so permitted.
13. DEFAULT, BREACH, WAIVER:
13.1 The proper and complete performance of each covenant of this Agreement shall be
deemed of the essence thereof, and in the event Licensee fails or refuses to fully and completely
perform any of said covenants or remedy any breach within thirty (30) days after receiving written
notice from Licensor to do so (or within forty-eight (48) hours in the event of notice of a railroad
emergency), Licensor shall have the option of immediately revoking this Agreement and the
privileges and powers hereby conferred, regardless of encroachment inventory fee(s) having been
paid in advance for any annual or other period. Upon such revocation, Licensee shall make removal
in accordance with Article 14.
13.2 No waiver by Licensor of its rights as to any breach of covenant or condition herein
contained shall be construed as a permanent waiver of such covenant or condition, or any
subsequent breach thereof, unless such covenant or condition is permanently waived in writing by
Licensor.
14. TERMINATION, REMOVAL:
14.1 All rights which Licensee may have hereunder shall cease upon the date of:
(a) revocation, (b) termination, (c) subsequent agreement, or (d) Licensee's removal of Pipeline
from the Crossing. However, neither revocation nor termination of this Agreement shall affect any
claims and liabilities which may have arisen or accrued hereunder, and which at the time of
termination or revocation have not been satisfied; neither party, however, waiving any third party
defenses or actions.
14.2 Within thirty (30) days after revocation or termination, Licensee, at its sole risk and
expense, shall (a) remove Pipeline from the right-of-way of Licensor, unless the parties hereto
agree otherwise, (b) restore property of Licensor in a manner satisfactory to Licensor, and (c)
reimburse Licensor any loss, cost or expense of Licensor resulting from such removal.
CSXT Form 2037G - Page 9
Revised May 2002 0
Agreement No. CSX-044933
15. NOTICE:
15.1 Licensee shall give Licensor's Chief Regional Engineer (Florida Business Unit, 5656
Adamo Drive, Tampa, FL 33619-3240) at least five (5) days written notice before doing any work
on Licensor's right-of-way, except that in cases of emergency shorter notice may be given to said
Chief Regional Engineer.
15.2 All other notices and communications concerning this Agreement shall be addressed
to Licensee at the address above, and to Licensor at the address shown on Page 1, c/o CSXT
Contract Administration, 1180; or at such other address as either party may designate in writing to
the other.
15.3 Unless otherwise expressly stated herein, all such notices shall be in writing and sent
via Certified or Registered Mail, Return Receipt Requested, or by courier, and shall be considered
effective upon: (a) actual receipt, or (b) date of refusal of such delivery.
16. ASSIGNMENT:
16.1 The rights herein conferred are the privileges of Licensee only, and Licensee shall
obtain Licensor's prior written consent to any assignment of Licensee's interest herein; said consent
shall not be unreasonably withheld.
16.2 Subject to Sections 2 and 16.1, this Agreement shall be binding upon and inure to
the benefit of the parties hereto and their respective successors or assigns.
16.3 Licensee shall give Licensor written notice of any legal succession (by merger,
consolidation, reorganization, etc.) or other change of legal existence or status of Licensee, with a
copy of all documents attesting to such change or legal succession, within thirty (30) days thereof.
16.4 Licensor expressly reserves the right to assign this Agreement, in whole or in part, to
any grantee or vendee of Licensor's underlying property interests in the Crossing, upon written
notice thereof to Licensee.
16.5 In the event of any unauthorized sale, transfer, assignment, sublicense or
encumbrance ofthis Agreement, or any of the rights and privileges hereunder, Licensor, at its
option, may revoke this Agreement by giving Licensee or any such assignee written notice of such
revocation; and Licensee shall reimburse Licensor for any loss, cost or expense Licensor may incur
as a result of Licensee's failure to obtain said consent.
16.6 In the event of sale or other conveyance by Licensor of its Right-of-Way, across,
under or over, which the Crossing is constructed, Licensor's conveyance shall be made subject to
the right of Licensee to continue to occupy the Crossing on the specific segment of Right-of-Way,
and to operate, maintain, repair, renew thereon and to remove therefrom the facilities of Licensee,
subject to all other terms of this Agreement.
CSXT Form 2037G - Page 10
Revised May 2002 0
Agreement No. CSX-044933
17. TITLE; LIENS, ENCUMBRANCES:
17.1 Licensee understands that Licensor occupies, uses and possesses lands, rights-of-
way and rail corridors under all forms and qualities of ownership rights or facts, from full fee
simple absolute to bare occupation. Accordingly, nothing in this Agreement shall act as or be
deemed to act as any warranty, guaranty or representation of the quality of Licensor's title for
any particular Right-of-Way in the Crossing occupied, used or enjoyed in any manner by
Licensee under any rights created in this Agreement. It is expressly understood that Licensor
does not warrant title to any Right-of-Way in the Crossing, and Licensee will accept the grants
and privileges contained herein, subject to all lawful outstanding existing liens, mortgages and
superior rights in and to the Right-of- Way, and all leases, licenses and easements or other
interests previously granted to others herein.
17.2 The term "license," as used herein, shall mean with regard to any portion of the
Right-of- Way which is owned by Licensor in fee simple absolute, or where the applicable law of
the State where the Crossing is located otherwise permits Licensor to make such grants to
Licensee, a "permission to use" the Right-of-Way, with dominion and control over such portion
ofthe Right-of-Way remaining with Licensor, and no interest in or exclusive right to possess
being otherwise granted to Licensee. With regard to any other portion of Right-of-Way
occupied, used or controlled by Licensor under any other facts or rights, Licensor merely waives
its exclusive right to occupy the Right-of-Way and grants no other rights whatsoever under this
Agreement, such waiver continuing only so long as Licensor continues its own occupation, use
or control. Licensor does not warrant or guarantee that the license granted hereunder provides
Licensee with all of the rights necessary to occupy any portion of the Right-of-Way. Licensee
further acknowledges that it does not have the right to occupy any portion of the Right-of-Way
held by Licensor in less than fee simple absolute without also receiving the consent of the
owner(s) of the fee simple absolute estate. Further, Licensee shall not obtain, exercise or claim
any interest in the Right-of-Way that would impair Licensor's existing rights therein.
17.3 Licensee agrees it shall not have nor shall it make, and hereby completely and
absolutely waives its right to, any claim against Licensor for damages on account of any
deficiencies in title to the Right-of-Way in the event of failure or insufficiency of Licensor's title to
any portion thereof arising from Licensee's use or occupancy thereof.
17.4 Licensee agrees to full and completely indemnify and defend all claims or litigation
for slander of title, overburden of easement, or similar claims arising out of or based upon
Licensee's facilities placement, or the presence of Licensee's facilities in, on, or along the Crossing,
including claims for punitive or special damages.
17.5 Licensee shall not at any time own, or claim any right, title or interest in or to
Licensor's property occupied by the Crossings, nor shall the exercise of this Agreement for any
length of time give rise to any right title or interest in License, to said property other than the
license herein created.
CSXT Form 2037G - Page 11
Revised May 2002 0
Agreement No. CSX-044933
18. GENERAL PROVISIONS:
18.1 This Agreement, and the attached specifications, contains the entire understanding
between the parties hereto.
18.2 Neither this Agreement, any provision hereof, nor any agreement or provision
included herein by reference, shall operate or be construed as being for the benefit of any third
person.
18.3 Neither the form of this Agreement, nor any language herein, shall be interpreted or
construed in favor of or against either party hereto as the sole drafter thereof.
18.4 This Agreement is executed under current interpretation of applicable Federal, State,
County, Municipal or other local statute, ordinance or law(s). However, each separate division
(paragraph, clause, item, term, condition, covenant or agreement) herein shall have independent and
severable status for the determination of legality, so that if any separate division is determined to be
void or unenforceable for any reason, such determination shall have no effect upon the validity or
enforceability of each other separate division, or any combination thereof.
18.5 This Agreement shall be construed and governed by the laws of the state in which
the Pipeline and Crossing are located.
19. RIDERS:
The following Rider(s) is/are herewith attached and included herein:
[ X ] Telecommunication Cable or Fiber Optic line
CSXT Form 2037G - Page 12
Revised May 2002 0
Agreement No. CSX-044933
IN WITNESS WHEREOF, the parties hereto have executed this Agreement in duplicate
(each of which shall constitute an original) as of the date and year first above written.
Witness for Licensor:
CSX TRANSPORTATION, INC.
By:
Print/Type Name:
Print/Type Title:
Witness for Licensee:
CITY OF CLEARWATER PUBLIC
UTILITIES DEPARTMENT
By:
Countersigned:
Who, by the execution hereof, affirms that he/she
has the authority to do so and to bind the Licensee
to the terms and conditions of this Agreement.
Print/Type Name: William B. Horne II
Brian J. Aungst
Mayor-Commissioner
PrintlType Title: City Manager
Tax Identification Number:
,", ,/
Authority under Ordinance or
Resolution No. 03-19
dated
ATTEST:
Cynthia E. Goudeau
City Clerk
COMMUNICATIONS CABLE OR FIBER OPTIC LINE PROTECTION RIDER
1. No construction of any type pursuant or related in any way to this Agreement shall
be commenced by Licensee, or by any agent, representative, contractor, subcontractor of Licensee,
without Licensee first giving at least thirty (30) days written notice to the following Parallel Cable
Occupier(s):
("MCI")
Mr. Bryan Tooley
MCI Telecommunications Corporation
2250 Lakeside Blvd
Dept 42855 Location 642
Richardson, TX 75082
Phone No. (800) 624-9675
or (972) 656-5159
(NOTE: WRITTEN CONSENT OF MCI IS ALSO
REQUIRED)
2. The notice shall be accompanied by drawing(s) showing the general plan, elevation,
details and methods of Licensee's proposed construction, and the location ofOccupier(s)' cable or
facilities in relation to Licensee's proposed construction.
3. Prior to any construction, Licensee must locate and identify, any existing cable,
wire or fiber optic line (including any appurtenances thereto) of said cable occupier(s) traversing or
located in, on, or immediately adjacent to the proposed Crossing, at Licensee's sole risk.
4. Any changes, alteration, relocation or protection ofwire(s), cable(s) or facilities of
such Occupier(s), required by said Occupier(s), shall be at Licensee's sole expense except as
otherwise negotiated between Licensee and said Occupier(s).
5. Licensee shall be solely responsible and liable for any damage to (e.g., cutting,
dislocating, etc.) said wire(s) or cable(s), and appurtenances thereto, resulting in any way from
Licensee's exercise of rights or privileges under this Agreement.
6. Licensee shall defend, indemnify and hold Licensor harmless from any such
damage claims and any relocation or protection costs of said Occupier(s).
CSX TRANSPORTATION, INC.
Licensor:
(Initial)
(Date)
CITY OF CLEARWATER PUBLIC
UTILITIES DEPARTMENT
Licensee:
(Initial)
(Date)
FORM CSXT 7455 -Rev. 11/01/02 (page 1 oi2)
APPLICATION FOR PIPELINE
CROSSING OR PARALLELING PROPERTIES AND TRACK
Submit one original and one copy of both the application and drawing along with a $650.00 nonrefundable
Application Fee to CSX Transportation, Property Services 1180,500 Water Street, Jacksonville, FL 32202.
Application and plans must be approved and written authority received from the Railroad before construction is begun.
Your proposal and construction must be in accordance with CSXT's Specifications, the American Railway
Engineering and Maintenance-of-Way Association (AREMA) and any current governing laws orregulations. Note:
Specifications furnished in the Application Package are to be used as a guideline only. CSXT reserves the right to
approve or decline any application.
PLEASE SIGN BEFOR.E COMPLETING:
Agreement No.:
I affIrm the information I am furnishing in this application will comply with the current AREMA Standards, governing
laws or regulations, and accurately reflects the prop sed construction plans:
~.. .
Application Date:
.' -. ".
2..-i7-03
Signature:
lProj ect Owner Information:1 ~ Check here if agreement should be mailed to this address
1. Complete Legal Name of applicant as it would appear in a legal document (inaccurate information Will delav
your request): . . .
City of ClearWiterPublic Utilities Department
2. Company Contact Name: Michael D. Quillen, P .E.
Title: City Engineer
3. Telephone: (llli. 562-4960 Fax: ~ 562-4755 E-Mail: mquillen@clearwater-f1.com
4. Street Address: 100 S. Myrtle A venue City: Clearwater State: FL Zip: 33756
5. Type of business:
o Corporation (State of incorporation )
o Partnership (Type and State of Partnership )
o Individual 0 Developer IX. Municipality 0 Other
!Engineer/Consultant Information:1 0 Check here if agreement should be mailed to this address
6. Company Name: McKim & Creed. P. A.
7. Company Contact Name:Norman J. Scally
8. Telephone: 0z.2s) .442-7196 Fax: C111> 461-3827
9. Street Address: 601 Cleveland Street #205 City:
Title: Project Engineer
E-Mail: nscally@mckimcreed.com
Clearwater State: FL Zip: 33755
!project Information:1 (Note: Metric Information will NOT be accepted.)
10. Is this installation: XI New 0 Revision to existing 0 Attachment to existing 0 Upgrade to existing
11. If not a new installation, furnish existing Agreement Number: N I A
12. If this installation is to be a supplement to your master (general) agreement, furnish:
Agreement Number: N I A Date: N / A
13 . Your Reference Number: N I A
14. Work to be performed by:
o Applicant's employees Is Applicant an Aegis member? 0 Yes 0 No
KI Contractor Contractor Name: To he selected by City
15. Town Location: Clearwater County: Pinellas StateIProvince: FL
(Form continued on Page 2)
/proj ect Information Cont'd:1
FORM CSXT 7455 - Rev. 11/01/02 (page 2 of2~
16. Product to be Conveyed: Reclaimed Water Flammable: 0 Yes [X No
Temperature: 75 deg- F
17. Maximum Working Pressure: 100 p>:;; Field Test Pressure: J 50 p1=:i Type Test: hvdrostatic
18. Location of Shut-Off Valves: 600'. W. of centerline of tracks & 335' E _ of centerline of tpFlC'l
19. Number: 0 Manholes-.N1A.. 0 Other (describe) N / A
to be located within Railroad corridor. Manholes shall be flush with top of ground and dimensions
of ancillary structures are required on dra'wing.
20. Distance from manholes/other to nearest track: N / A
21. Angle of Crossing: 90 deg Number of Tracks to be crossed: one
22. PIPE SPECIFICATIONS: CARRIER PIPE: CASING PIPE:
Material Ductile Iron Steel
Material Specifications & Grade ANSI/AWWA CI51/A21.51 ASTM A139 Grade E
Minimum Yield Strength of Material PSI 42 , 000 35 , 000
InSide Diameter 16.80 inches 29 _] HR incheR
Wall Thickness 0.30 inch 0.406 inch
Outside Diameter 17.40 inches 30 inches
TypeofSeam Straig-ht Strai~ht
KindofJoints Mechanicallv Restrained Butt Weld
Tq1:8l Length Within Railroad RJW 50 feet 50 feet
Tunneling (Liner Plates) N / A Note: Attach manufacturer's ShOD detail and computations that
include plate thickness and eaee;
Vepts: Number N / A Size N / A Height aboveground N / A
Seals: 0 One End IX Both Ends
Bury depth: Base ofrail to top of casing: 6 feet 5 inches
. Not beneath tracks: 6 feet 4 inches
(Below ditches) Nl A feet, N / A inches
Cathodic Protection: 0 Yes ~ No Protective Coating: Q{Yes (Kind) Hot Coal Tar EnamelD No
23. Method of installation: Bore and Jack
24. Temporary track support or riprapping required? D.. Yes IX No (Describe and Detail on Drawing)
25. Wires, poles, obstructions to be relocated? 0 Yes El No (Describe and Detail on Drawing)
26. Is this both a Crossing and Parallelism? 0 Yes ~ No
27. Crossing location: 2.380 feet South (direction) from Railroad Milepost: 875
Ifknown: Valuation Station: N / A Valuation Map Number: N / A
If known: Latitude/Longitude: N / A
Ifknown: StreetAddress ofCrossin~~: Jeffords St.- and CSX ROW.
28. Parallelism location: Beginning: N / A feet N / A (direction) from RR Milepost: N / A
and Ending: N / A' feet N / A (direction) from RR Milepost: N / A
29. Total length on Railroad R/W: 50 ft Length Crossing: 60 feet Length Paralleling: N / A
30. Will1inebeentirelywithinapublicroadR/W?~ Yes 0 No DOT/AARCrossingNo.: 626-796-F
**Ifyou answered yes, road name, number, and width of public right-of-way are required on drawing
31. a) Will this occupancy connect to an existing facility within Railroad corridor? 0 Yes IX No
b) If Yes, name facility owner(s): N / A
/Railroad Use Only:1
Division
Absolute No.: /'-) ;;~ 7 ,~~. 7
Valuation Station: \. I iftLl ~';:: <~:~
Milepost: ~ '/- rl"?5'.4-':.:;
l~:......~' ::;'Y, !
. f ....:~; .ll,.
SubdiVl'sl'on (i. /(,;,.~tJ (J I.' a:h-y,o
IL._- . __Vi.J "'JJf::::.~~I'L.
Valuation SectioIllMap No.:
No. ofCrossin~s: I
~J "7" (..", ;.'.' I i'":'P ...)
., .., / 1// ", ... ,"': )'.'.
~_... Il...._. ~... _,.. ...;:,") #>
.
Roadmaster No.:
Contr. Type:
Fiber?
RR XING
RR XING SIGNAL ~ GATE AR
._.--.L..cONCJlALK__._UGT.'.__:l-=-:_._
~ - X DRAIN A:' INlET~ r
~ TOP EL = 37.70
o INY 12"X18- RCP (N) =35.17
8 INY 12"X18" RCP (S) =35.01 I
~ INY 12"X18" RCP (W) =35.35 I
;::::
......
-
N
o
z
:5
c..
DRAINAGE MANHOLE
RIM EL = 37.80
INV 12"X18" RCP (E) =35.47
INV 6" PYC (W) =35.38
____ 3' HEDGE
UNK CLUST. 3"-5"
o
DRAINAGE MANHOLE
RIM EL = 38.13
INY 24" RCP (N) =34.54
INV 12"XI8" RCP (S) =34.95
INV 12"XI8" RCP (W) =34.67
0PA 14"
VIDEO
CAMERA POLE
RAILROAD \
CROSSING \
Cm.JTROL ~
BOX 0
DRAINAGE MANHOLE
RIM EL = 37.84
INY 6" PYC (0 =34.12
TOP B" CIP WATER LINE (E&W) =34.53
INY 24"X38" RCP (5) =32.60
Lx
x
x
JEFFORDS S"'ffiETI -:~. - - - - - - - -
... . . . co
129+00. x
- - - - - - - - - - - - - - - - - - .~- -8"SS- - - - -
CE &: METER BOX ~ 30'
B:
'-..
130+00 0:::
,
,
f
/
--------
o -----7'------
L()
i
- - - -1Z"x18"SD- - _
....-..-..-m--GHW.__
i
!
.~f;
.........-OH\
BORE AND JACK
60 LF. OF 30- SlEEl CASING
/ASPHAL T
DRIVE
DRAINAGE INLET
TOP EL = 37.74
INY 24"X38" RCP (N) =33.39
INY 24"X38" RCP (S) =33.63
DRAINAGE MANHOLE
RIM EL = 37.85
INV 24X38"ERCP (N) =32.65
INV24X38'-1:RCF'W-=.JT.8
N
SPHALT
, AVEMENT
ci
==
"C
ex:
a::
X
en
u
:E
.~
Q)
c..
Iii
Cl
c
'i
!!
Q
o
co
~
o
......
.9
SI
en
52
cij
.6. 'P.I'T/n. I&CREED .~~,("Y~.I\ 11" f.' r <)41
~~Y"'-.NJ.Vl _ _l[:.J..LtA..I, I'.. . \ , ~
601 Cleveland Street. Suite 205 -J L Cj Jql! .:S ~S',
~~~~~~rfmt!lih596. 1. ;Z)r'~..:=i\
MOO02B67 EBOOOBe91
www.mckimcreed.com
o 20'
~
SCALE: 1"= 20'
HARBOR OAKS
RECLAIMED WATER TRANSMISSION
AND DISTRIBUTION SYSTEM
BORE AND JACK
JEFFORDS ST. & CSX RR
PLAN
DAlE:
MCE PROJ. I
ORAlItl
DESIGNED
CHECl<EIl
PROJ. MGR.
12/31 /02
0992-01114
JIll
NJS
NJS
[AM
FIGURE 1
....
"
38 CSX RAILROAD
- 38
----n-tJ- -
I-- - f-- - - - -
36 r\ 12"x1S SD 36
\i UGT
0
f\ 24"x3S"SD
34 34
>.
,.
. .. .. ...
-,-,.. " c., . ~ ...
BORE AND J) CK - F'-
32 60 L.F. OF 3 bIt z a:: .'32
'., .. . ---. - ~ <P- H ... .. ..
.. oJ. .~~L.. '-'r>...." , \ Co ....JI--
...- U
.....
.. .. V / / / / / / / / / / / / / / /j / / / ..
..
V/7/// '/7// / / / / / / / / // /.
30 30
V/77/ 7777/77////////
V//// ///////////////
28 / l ) ~ 28
- '"
'"' '"' '"' ""
a:: a:: a:: a::
w ~ ~ w
26 > >
......., ......., ......., ......., 26
0 I~ ~ ~
z
w w " " w w
a CD v CD 10 Z 10 Z co CD a CD
N N. n ;n 0> in 0 ...-
~ LOO 0\ LOa + 'b<(~ + <{ 6 LOO 6 LOa
vI") vI") 0> no..... 0> II UN vI") vi'
N N N N o i' I") n
24 - . z-'~ 1")....Ja:j - . 0,..,-)
...- o~ ...- o~ ...- ...- ...- o~ ...- 24
-w WN i-ri
~I:: II ~ II II ;:: w~ ~ ;:::: z~ II ~ II II ~. II II
(/) ~w (J') COw (/) CD (/) (J') W (/) !:! (/) COw (/) COw
...-- .....- .....-
129+00 130+ 00
.lvR<IM&CREED '. Lxc...'.I/1.1 L.? j lV~ :Ef HARBOR OAKS DAlE: 12/31/02
RECLAIMED WATER TRANSMISSION liCE PROd. I 09112-01 D4
_.j L {} {i- (tIl ;{ ~J DRAM JID
501 Cleveland Street. SuIte 205 AND DISTRIBUTION SYSTEM DESIGNED NJS
OfEa<ED NJS
Clearwater. FL 33755 -T .. i) .3 BORE AND JACK
Phone: (72lJ442-7195. PRO.I. IIGR. EAIl
Fax: (727) 1-3827 ~. tY-t ~.,. JEFFORDS ST. & CSX RR
MGOO28117 EBaacl88111 PROFILE FIGURE 2
w_.meklmcreed.eom
CARRIER
& CASING SIZES
CASING/
WALL
THICKNESS
.188
.188
.219
.250
.281
.344
.406
'...
~
CARRIER PIPE (RCW)
SPACERS REQUIRED
AS NOTED ABOVE
CARRIER CASING
4" 12"
6" 14"
8" 16"
10" 18"
12" 20"
14" 24"
16" 30"
SECTION A-A
25~ MIN.
OU.TSI.,.DE .RAIL,. ..........
CROSS- TIE .. \
't. RAILROAD TRACKS
25' MIN.
RAIL BED (BALLAST)
o::~
: Oz
<0 u...-
z I -.J
~ LnZZ
~<(
~
i-r>
CASINl CARRIER
PIPE PIPE A ~
~:dt:: ~
A.J
12"12"
10' -0"
ENDS OF CASING TO BE
SEALED
CARRIER PIPE SPACERS (ONE SPACER REQUIRED
MAX. 1'-0" FROM EACH SIDE OF JOINT. MAX.
DISTANCE BETWEEN SPACERS=10'-0")
CSX PIPELINE CROSSING DETAIL
NOT TO SCALE
.~&CREED
"beLLtd t ui2. r:.:h.
'l "\ I.~(t'{/. ~~.',<
,_..1.._ l.! '1;-" - ",'~ .._~
.:.2,."1 ,L\
HARBOR OAKS
RECLAIMED WATER TRANSMISSION
AND DISTRIBUTION SYSTEM
601 Ceveland Street, Suite 205
Cearwater, . Fl 33755
Phone: (727)442-7196,
Fax: (727)461-3827
MOOO2887 EIlCIOCle8I1
w_.mcklmcreed.com
CSX PIPELINE CROSSING DETAIL
DAlE: 1/2/03
liCE PRO.l, 0992-0104
DRAlWl JTD
DESlGNED N.lS
CHEa<ED N~
PROJ.IIGR. EAII
FIGURE 5