FLD2008-05013, 100 CORONADO DR, 201, 215,219 S GULFVIEW BLVD - October 21, 2008 - AMENDED STAFF REPORTCDB Meeting Date
Case Number:
Agenda Item:
Owner:
Applicant:
Representative:
Address:
October 21, 2008
FLD2008-05013 (Related to DVA2008-00001)
E 1 (Related to F 1)
K & P Clearwater Estate, LLC
Clearwater Beach Resort Hotel, LLC
E. D. Armstrong III, Esquire, Johnson, Pope, Bokor, Ruppel & Burns, LP
100 Coronado Drive, 201, 215 and 219 S. Gulfview Blvd.
CITY OF CLEARWATER
PLANNING DEPARTMENT
STAFF REPORT
GENERAL INFORMATION:
REQUEST: (1) Flexible Development approval to Terminate the Status of a
Nonconformity for density (200 overnight accommodation units; where
137 overnight accommodation units are permitted today) within the
Tourist District, under the provisions of Section 6-109.C; (2) Flexible
Development approval to permit a 450-unit Overnight Accommodation
use (through an increase of the permitted density of 250 overnight
accommodation units from the density pool created pursuant to Beach by
Design), with a lot area of 119,856 square feet (2.75 acres), a lot width
of approximately 545 feet along Coronado Drive and 227 feet along
proposed Second Street, a front (east along Coronado Drive) setback of
zero feet (to building and pavement), a front (south along proposed
Second Street) setback of 18.83 feet (to building), a front (west and
north along South Gulfview Boulevard) setback of zero feet (to
building), a building height of 150 feet (to roof deck) and either 463
valet-only parking spaces or 455 valet-only parking spaces with eight
public parking spaces at 1.028 or 1.011 parking spaces per hotel room,
respectively, as well as the allowance of a two-year time frame to submit
for a building permit, as a Comprehensive Infill Redevelopment Project,
under the provisions of Section 2-803.C; (3) To reduce the required
foundation landscaping along Coronado Drive and S. Gulfview
Boulevard from five to zero feet (to building and pavement), as a
Comprehensive Landscape Program, under the provisions of Section 3-
1202.G; and (4) Vacation of a portion of S. Gulfview Boulevard (former
bridge landing).
CURRENT ZONING: Tourist (T) District
CURRENT FUTURE LAND Resort Facilities High (RFH)
USE CATEGORY:
PROPERTY USE: Current Use: Vacant (temporary City public parking lot)
Proposed Use: Overnight accommodation use of a total of 450 rooms
(163.6 rooms/acre on total site) and a maximum of
37,000 square feet (0.31 FAR on total site) of amenities
accessory to the hotel at a height of 150 feet (to roof
deck).
Community Development Board - October 21, 2008
FLD2008-05013 - Page 1 of 14
EXISTING
SURROUNDING ZONING
AND USES:
North: Open Space/Recreation
(OS/R) District
South: Tourist (T) District
East: Tourist (T) District
West: Open Space/Recreation
(OS/R) District
Pier 60
Overnight Accommodations
(Aqualea/Hyatt - under construction)
Vacant, Retail Sales and Overnight
Accommodations
Beach and Gulf of Mexico
ANALYSIS:
Site Location and Existing Conditions:
The 2.75 acres is located directly south of Pier 60 between Coronado Drive and South Gulfview
Boulevard, north of Second Street. The subject property is currently vacant, but used as a temporary City
public parking lot. The properties were previously developed with various motels/hotels (Days Inn, Beach
Towers Motel, Spyglass Motel and Golden Beach Motel) and numerous retail sales and restaurant uses.
The overall property includes several vacated and dedicated rights-of-way (see next paragraph for
description).
On October 19, 2004, the Community Development Board (CDB) approved a Flexible Development
application for the construction of a 350-unit hotel with associated amenities and 75 attached dwellings as
a mixed-use development (FLD2004-02013). The City Council approved a companion Development
Agreement on February 17, 2005 (Case No. DVA2004-00001). These development approvals authorized
the following:
¦ Use of 250 hotel rooms from the Beach by Design density pool;
¦ Maximum building height of 150 feet;
¦ Vacation of a portion of the right-of-way for Gulfview Boulevard between Coronado Drive and
proposed Second Street;
¦ Vacation of the First Street right-of-way between Coronado Drive and Gulfview Boulevard;
¦ Dedication of right-of-way for proposed Second Street between Coronado Avenue and Gulfview
Boulevard; and
¦ Dedication of right-of-way for Coronado Drive between proposed Second Street and Gulfview
Boulevard.
On May 17, 2005, the CDB approved a Flexible Development application amending the prior project to
modify the location of an elevated pedestrian walkway over South Gulfview Boulevard (FLD2004-
02013A). On March 16, 2006, City Council approved an amendment to this original Development
Agreement (DVA2004-0000IA), which dealt with issues associated with Beach Walk construction and the
timing of the dedication of land for Relocated 1St Street (to be known as Second Street once constructed), as
well as for the construction of Relocated 1 st Street.
Pier 60 and the public parking lot is to the north of this property and is zoned Open Space/Recreation
(OS/R) District. Properties to the east across Coronado Drive are zoned Tourist (T) District and are (or
were) developed with overnight accommodation uses and retail sales and service uses. At least two of the
properties are currently vacant, as the former overnight accommodation uses have been demolished, but
presently contain temporary construction trailers for the Aqualea/Hyatt project. The Aqualea/Hyatt
Community Development Board - October 21, 2008
FLD2008-05013 - Page 2 of 14
project, which is a 250-room hotel with 18 attached dwellings, is located to the south across proposed
Second Street and is zoned Tourist (T) District.
Development Proposal:
The proposal is to redevelop the site with a 450-unit/room destination resort hotel, consisting of 250
traditional hotel units and 200 vacation/interval ownership (timeshare) units. The proposed resort will
include amenities accessory to the hotel, including a restaurant, lounge, retail sales, pool, spa, ballroom and
meeting space. The proposal changes the architectural style from the prior approved project to a tropical
modern architecture, which is appropriate and aesthetically pleasing for this beachfront property and
complements the tropical vernacular envisioned in Beach by Design, and incorporates pedestrian access
components to Beach Walk. The proposal eliminates the approved pedestrian bridge to Clearwater Beach,
instead providing for the construction of a loggia and a palm court pedestrian area on the west side. The
building mass consists of a four-story base, two 150-foot towers and a 95-foot tall connecting element that
links the towers and base together. The building design incorporates a curved facade on the north side
where public meeting space, ballroom and spa softens and transitions the visual appearance moving east to
west. On the north end, the curved mass of the base is reinforced by one of the two 150-foot towers (hotel
tower). The towers incorporate a similar design where the towers are oriented on an east-west axis with the
tower units angled to give occupants unimpeded views of the Gulf. Timeshare units are located in the
southern tower. A 95-foot tall connecting element is aligned on a north-south axis and includes timeshare
units, providing a transition between the vertical towers and the horizontal base. Smaller scale decorative
trellises, awnings, louvered panels and translucent railings soften the mass of the building. On the west
side of the building the mass of the base is carved back to create a curved public palm court. The palm
court is a landscaped focal point for the hotel, located both on the subject property and within the S.
Gulfview Boulevard right-of-way that will be a walkable part of Beach Walk. A covered loggia is located
along the west side of the building on the subject property, providing pedestrian access to the resort hotel,
the retail shops and restaurant. The palm court and covered loggia are slightly elevated providing a
viewing platform toward the Gulf of Mexico for public use.
The building is designed with the porte cochere and the lower lobby on the grade level. This lowest level
provides building entrance areas on the east side, storage areas and 218 parking spaces. Level 1 is the main
lobby level and includes hotel administrative offices, restaurant, bar, retail sales areas and a 10,500 square-
foot grand ballroom. Level 2 provides an employee office area, 149 parking spaces and eight timeshare
units. Level 3 provides a back of house area, a 5,000 square-foot junior ballroom, meeting rooms, 96
parking spaces and 17 timeshare units. The amenity Level 4 provides a 13,890 square-foot spa, 3,890
square-foot fitness center, 17 timeshare units, the main pool between the two towers and a small timeshare
pool in the southwest portion of the amenity deck south of the timeshare tower. Levels 5 - 9 have 24 hotel
rooms and 22 timeshare units per floor. Level 10 provides 24 hotel rooms and eight timeshare units, as
well as providing access to the rooftop recreation deck on the top of the connector portion of the building
between the two towers. Levels 11 - 14 provide 24 hotel rooms and eight timeshare units for each floor.
The Penthouse Level 15 provides 10 hotel rooms and eight timeshare units. The proposed hotel consists of
four rooftop levels - the amenity deck at 38.67 feet accessible to the guests; the spa roof (inaccessible to
guests) on the north end of the hotel tower at a height of 48.17 feet; the third being the connector element
between the two towers at a height of 95 feet that includes a recreation area for guests; and the fourth being
the roofs of the hotel and timeshare towers having a height of a maximum of 150 feet to the flat roof deck
(inaccessible to guests). That portion of the building exceeding 100 feet in height is separated from the
Aqualea/Hyatt building to the south by 140.67 feet, exceeding the Beach by Design minimum requirement
of a 100-foot separation. The materials and color of the building will support the tropical modern
architecture and its natural surroundings. The building will be painted sand dollar white, accented by
honed gray granite stone veneer. The window mullions, railing caps, louvered panels and trellises will be
Community Development Board - October 21, 2008
FLD2008-05013 - Page 3 of 14
arcadia silver. Balcony railings will be clear glass. The main pool area is located between the two towers
in the west center of the building to minimize noise and visual distractions to the Aqualea/Hyatt resort hotel
to the south. With the height and location of the adjacent Aqualea/Hyatt resort hotel and condominiums,
the proposed hotel design is compatible with the surrounding uses.
Parking for the hotel guests and employees is provided in a parking garage on three levels containing 463
valet-only parking spaces or 455 valet-only parking spaces with eight public parking spaces at 1.028 or
1.011 parking spaces per hotel room, respectively. The parking plan provides the two parking options,
showing the eight public parking spaces should City Council decide to retain the spaces within this garage
or to remove the eight public spaces and all parking in the garage would be private spaces. The
Development Agreement provides an option for the eight public parking spaces to be eliminated from the
parking garage for a payment in lieu of to be placed off-site. The two upper parking levels are accessed by
a ramp located just inside the building on the south side of the building, which is accessed from Second
Street. No guests or other public will access the parking garage; only valet employees will park and
retrieve vehicles from the parking garage. The parking garage will include stacked or tandem spaces,
where another car must be moved to get the stacked or tandem car out, and will employ the stacking of
vehicles in drive aisles to create additional valet spaces when necessary, resulting in a total of 568 parking
spaces in a worst case scenario (full occupancy and a large banquet).
The site is designed with two driveways on Coronado Drive. The northern driveway will be an entrance
only, providing access to the porte cochere for the valet service. A loading area is provided on the south
side of the site off Second Street, providing three loading spaces and access to the compactor for solid
waste trucks. Valet drivers will access the parking garage by a driveway provided off Second Street on the
southwest portion of the site.
The applicant is requesting a two-year development order due to market conditions. Section 4-407
specifies that an application for a building permit must be submitted within one year of the date the CDB
approves the project, unless otherwise specified under this approval.
The proposal includes the proposed vacation of the former pedestrian bridge landing at the northwest
corner of the property. This right-of-way is no longer necessary. While action on this vacation request is
solely a decision by the City Council, the request has been included with this application to show the
relationship of the proposal to street rights-of-way and to include the land area into the overall site area for
calculation purposes.
Density: Pursuant to the Countywide Future Land Use Plan, the maximum density for properties with a
designation of Resort Facilities High is 50 overnight accommodation units per acre. Based on the 2.75
acres zoned Tourist District, a maximum of 137 overnight accommodation units are permissible under
current regulations. The overall site was formerly developed with a total of 200 units, which was
nonconforming to current regulations. The applicant is requesting Termination of Status of Nonconformity
for density to maintain the same number of overnight accommodation units in a conforming manner (see
discussion below). Additionally, this site was originally granted 250 hotel rooms from the hotel density
pool created by Beach by Design under Case Nos. FLD2004-02013/DVA2004-00001. The overall density
for this project is 163.6 overnight accommodation units/rooms per acre.
Termination of Status of Nonconformity: The development proposal includes a request for Termination of
Status of Nonconformity for density (200 overnight accommodation units; where 137 overnight
accommodation units are permitted today). The nonconforming status of the prior hotel density has been
determined to still be valid, even though all motels/hotels on the overall property have been demolished, due
Community Development Board - October 21, 2008
FLD2008-05013 - Page 4 of 14
to the status of the approval of Case Nos. FLD2004-02013/DVA2004-0000 L An important factor in this
case is the ability to retain an overnight accommodation use on the beach where many hotels/motels have
been lost to condominium (attached dwelling) construction. The criteria for Termination of Status of
Nonconformity, as per Section 6-109 of the Community Development Code and outlined in the table below,
including compliance with perimeter buffer requirements, the provision of required landscaping for off-
street parking lots and bringing nonconforming signs, lighting and accessory uses/structures into
compliance with the Code will be met with this development proposal.
Consistent I Inconsistent
1. Perimeter buffers conforming to the requirements of Section 3-1202.1) of the N/A
Community Development Code shall be installed.
2. Off-street parking lots shall be improved to meet the landscaping standards N/A
established in Section 3-1202.E of the Community Development Code.
3. Any nonconforming sign, outdoor lighting or other accessory structure or accessory X
use located on the lot shall be terminated, removed or brought into conformity with
this development code.
4. The comprehensive landscaping and comprehensive sign programs may be used to X
satisfv the requirements of this section.
Pursuant to Section 3-1202.1), there are no perimeter buffers required in the Tourist District. The
temporary City public parking lot will be removed upon construction of this proposal. All proposed
parking will be within a parking garage, where landscaping is not required. Any prior nonconforming
signs, outdoor lighting or other accessory structures/uses have already been removed with the demolition of
the motels/hotels from the overall property. A Comprehensive Landscape Program has been submitted for
this proposal, as the foundation landscaping requirement is not met and reductions are requested. Should
the applicant desire attached or freestanding signage in excess of minimum Code requirements, the
Comprehensive Sign Program may be used for proposed signage.
Impervious Surface Ratio (LS.R.): Pursuant to Section 2-701.1 of the Community Development Code, the
maximum allowable I.S.R. is 0.95. The overall proposed I.S.R. is 0.92, which is consistent with the Code
provisions.
Minimum Lot Area and Width: Pursuant to Table 2-803 of the Community Development Code, the
minimum lot area and width for overnight accommodation uses ranges between 10,000 - 20,000 square
feet and 100 - 150 feet respectively. The subject property is 119,856 square feet (2.75 acres) in area and
has approximately 545 feet of frontage along Coronado Drive and approximately 227 feet of frontage along
proposed Second Street. The proposal is consistent with these Code provisions.
Minimum Setbacks: Pursuant to Table 2-803 of the Community Development Code, the minimum front
setback for overnight accommodations can range between zero - 15 feet, the minimum side setback can
range between zero - 10 feet and the minimum rear setback can range between zero - 20 feet. This site
encompasses an entire block of property, therefore only front setback requirements are applicable. The
proposal includes a front (east along Coronado Drive) setback of zero feet (to building and pavement), a
front (south along proposed Second Street) setback of 18.83 feet (to building) and a front (west and north
along South Gulfview Boulevard) setback of zero feet (to building). There are no required setbacks for a
Comprehensive Infill Redevelopment Project use.
While the proposal has been advertised with setback reductions to zero feet along Coronado Drive on the
east and along S. Gulfview Boulevard on the north and west, the building does not extend fully to the zero-
Community Development Board - October 21, 2008
FLD2008-05013 - Page 5 of 14
foot setback for the entire street frontages. Along Coronado Drive, the structural fins for the two towers
are located at a zero-foot setback. Actual floor area between these structural fins is located approximately
five feet from the property line. Balconies for units between these structural fins for the amenity Level 4
through Level 15 extend, however, to the property line. The facade of the building north and south of these
towers varies 6 - 16 feet in distance to the property line. At the porte cochere, the facade of the lobby is
approximately 46 feet from the property line, although pavement for the porte cochere is located at a zero-
foot setback. Along the north side adjacent to S. Gulfview Boulevard, only the northwest corner of the
building is located at the advertised zero-foot setback. The curved wall of the ballroom, junior
ballroom/meeting room and spa terrace is located approximately six feet to the north property line. The
building is located at a zero-foot setback along S. Gulfview Boulevard on the west side. Along the south
side adjacent to Second Street, the building is located 18.83 feet from the property line, exceeding the
required front setback of 15 feet. The previously approved project under FLD2004-02013 also included
setback reductions to zero feet along all frontage to the building. Setback reductions sought are a result of
right-of-way dedications for street relocations, provision of a dedicated turn lane on Coronado Drive and
incorporation of the project into Beach Walk. Landscaping improvements within the rights-of-way and on-
site will reduce impacts due to the reduced setbacks. Along the west side, the travel lanes for S. Gulfview
Boulevard curve away from the subject property, creating the large Beach Walk promenade area west of
the subject property, such that the setback reduction will not be visually apparent.
Maximum Building Heim Pursuant to Table 2-803 of the Community Development Code, the maximum
allowable height for overnight accommodation uses is 100 feet. Beach by Design permits buildings up to a
maximum of 150 feet through the use of bonus hotel units from the density pool, which this proposal has
been previously awarded. The proposed hotel consists of two towers at a height of 150 feet (a hotel tower
on the north side and a timeshare tower on the south side). A timeshare connector between the two towers,
which also extends south of timeshare tower, has been designed at a height of 95 feet. The amenity deck,
which includes the two swimming pools, is at a height of 38.67 feet. The height of the roof of the spa on
the north side of the hotel tower is 48.17 feet. That portion of the building exceeding 100 feet in height is
separated from the Aqualea/Hyatt building to the south by 140.67 feet, exceeding the Beach by Design
minimum requirement of a 100-foot separation. The proposed height of the lower and taller portions of the
tower is consistent and compatible with the height of the Aqualea/Hyatt project. This site is located within
the Beach Walk District of Beach by Design, which is the primary "beachfront" destination on Clearwater
Beach. The applicant has submitted documentation indicating compliance with the Beach by Design
criteria for no more than two buildings more than 100 feet in height within 500 feet of each other. The
proposal also complies with the Code requirements under the definition of "Height, Building or Structure"
for elevator and stair overruns and mechanical rooms, which are permitted to extend a maximum of 16 feet
above the otherwise permitted height. The timeshare connector between the two towers is designed to
provide a recreation area for guests. The definition of "Height, Building or Structure" permits structures
permanently affixed to the roof that permit rooftop occupancy only if such structures are within the
maximum allowable height of 100 feet. Since this timeshare connector is designed at a roof height of 95
feet and provides rooftop occupancy by guests, such structures can only be five feet in height. To ensure
any such structures envisioned with this proposal or in the future after construction is completed, any
approval of this application should be conditioned on such a structure height limitation. The design of this
project creates a form and function that will be consistent with and enhance the character of this area.
Minimum Off-Street Parking: Pursuant to Table 2-803 of the Community Development Code, the
minimum required parking is one parking space per unit, or 450 parking spaces. Parking for the hotel
guests and employees is provided in an on-site parking garage on three levels containing either 463 valet-
only parking spaces 1.028 parking spaces per unit/room) or 455 valet-only parking spaces (1.011 parking
spaces per unit/room) with eight public parking spaces, which will be 100 percent valet parked. Full valet
Community Development Board - October 21, 2008
FLD2008-05013 - Page 6 of 14
service will be provided so that guests and overnight visitors will not have to wait for spaces or circle the
garage looking for a parking space, therefore allowing traffic to flow smoothly into the parking garage off
the public street. The 463 parking spaces will be provided on the various parking levels as follows: Grade
Level - 218 spaces; Level 2 - 149 spaces; and Level 3 - 96 spaces. On the Grade Level, one option is to
provide eight public parking spaces, located in the southwest corner of the parking garage. Depending on a
decision by City Council, and set out in the Development Agreement, the public parking spaces could be
eliminated from the parking garage under a payment in lieu of providing the spaces. Of the 463 parking
spaces provided, 162 spaces are designed as stacked or tandem spaces where another car must be moved to
get the stacked or tandem car out. The submitted Parking Study demonstrates that stacking of vehicles in
drive aisles to create additional valet spaces when necessary will result in an additional 105 parking spaces
for a total of 568 parking spaces in a worst case scenario (full occupancy and a large banquet). The
submitted Parking Study also demonstrates that adequate parking will be available for guests, visitors and
employees. The companion Development Agreement sets out a parking protocol in Exhibit M to ensure
adequate parking is available and to minimize traffic backups at the porte cochere. The owner will also
record a covenant (Development Agreement, Exhibit F) to implement a trip generation management
program prior to the issuance of the Certificate of Occupancy to reduce trips to and from the site to ensure
adequate on-site parking is available for guests and employees. The parking garage must comply with the
Building Code and have a vertical clear height for all parking garage levels of not less than seven feet
including the entrance and exit. This clear height includes any structural beams, fire sprinkler pipes and
heads, electrical conduits and lighting, drainage pipes and any other building elements.
The site is designed with two driveways on Coronado Drive. The northern driveway will be an entrance
only, providing access to the porte cochere. The porte cochere drive will be one-way only travel (north to
south), two lanes wide with a separate additional lane for buses and be serviced by valet only. Airport
shuttles, taxis and limousines will use the drop-off area under the porte cochere on Coronado Drive. A
total of 21 vehicles can be stacked within the porte cochere area. There is a valet exit from the grade level
parking garage on the north side of the porte cochere, designed to minimize vehicular movement on the
public streets. Instead of a turn lane the entire length of the project along Coronado Drive, the turn lane
starts south of the drop-off area to provide access to Second Street for both this project and the
Aqualea/Hyatt project to the south. A landscape island with public sidewalk projects into the Coronado
Drive right-of-way to the travel lanes, providing a turn lane into the porte cochere. A loading area is
provided on the south side of the site off Second Street, providing three loading spaces and access to the
compactor for solid waste trucks. This loading area is across Second Street from a similar loading area for
the Aqualea/Hyatt project on the south side of Second Street. Valet drivers will access the parking garage
by a driveway provided off Second Street on the southwest portion of the site. The applicant will construct
sidewalks of a width and material within the adjacent rights-of-way according to that specified by Beach
Walk. The sidewalk along Second Street will be partially on the subject property and an access easement
will need to be recorded for this sidewalk prior to the issuance of the Certificate of Occupancy.
Mechanical Equipment: Pursuant to Section 3-201.D.1 of the Community Development Code, all outside
mechanical equipment must be screened so as not to be visible from public streets and/or abutting
properties. The applicant is proposing mechanical equipment to be located within mechanical enclosures
on top of the towers or on top of the flat roofs of the timeshare connector or spa, where the building
parapets will screen views of such mechanical equipment. Based upon the above, the development proposal
is consistent with the Code with regard to screening of outdoor mechanical equipment.
Sight Visibility Triangles: Pursuant to Section 3-904.A of the Community Development Code, to minimize
hazards at the driveway and street intersections on S. Gulfview Boulevard, Coronado Drive and Second
Street, no structures or landscaping may be installed which will obstruct views at a level between 30 inches
Community Development Board - October 21, 2008
FLD2008-05013 - Page 7 of 14
above grade and eight feet above grade within 20-foot sight visibility triangles. The proposed site and
landscape design meet this requirement.
Utilities: Pursuant to Section 3-911 of the Community Development Code, for development that does not
involve a subdivision, all utilities including individual distribution lines shall be installed underground
unless such undergrounding is not practicable. The civil site plan for this proposal indicates that all on-site
electric and communication lines for this new building will be placed underground in conformance with this
Code requirement.
Landscaping: Pursuant to Section 3-1202.1) of the Community Development Code, there are no perimeter
buffers required in the Tourist District for this site. This proposal includes a reduction to the required
foundation landscaping along Coronado Drive and S. Gulfview Boulevard from five to zero feet (to
building and pavement) through the Comprehensive Landscape Program. The foundation landscaping
reductions occur at the structural fins on Coronado Drive and at the northwest corner of the building on S.
Gulfview Boulevard. The reduction to the on-site foundation landscaping requirement is most evident
along the west side of the proposed building and its loggia. However, Beach Walk promenade landscaping
adjacent to the building will act as the foundation landscaping along this building edge. The site along the
north, east and south otherwise complies with the five-foot wide foundation landscaping requirement.
The applicant has worked with City Staff to ensure proposed landscaping and sidewalk improvements both
within the City's rights-of-way and on-site work together with the landscape design for Beach Walk to
ensure a seamless interface between this project and Beach Walk features reinforcing the pedestrian
oriented beach community. Medjool date palms will be installed along Coronado Drive and to the west
along S. Gulfview Boulevard, including the proposed palm court. Cabbage and Washington palms and
other salt-tolerant landscaping will be planted within the rights-of-way and on-site. Landscaping assists
with softening and reducing building massing to both pedestrians and motorists.
Solid Waste: The proposal will utilize hotel housekeeping staff to remove trash from units and transport
the trash to the trash compactor located on the south side of the property. Trash trucks will back in from
Second Street to access the compactor dumpster. The proposal has been found to be acceptable by the
City's Solid Waste Department.
Signage: No freestanding or attached signage is proposed at this time for this overnight accommodation
use. Freestanding signage in the Tourist District is restricted to a maximum height of four feet, or six feet
through a Comprehensive Sign Program. Any approval of this application should include a condition
allowing for freestanding signage, where such future freestanding signage must be a monument-style sign
meeting Code requirements and be designed to match the exterior materials and color of the building.
Additional Beach by Design Guidelines: Section B.3 requires the floorplate of any building exceeding 45
feet in height to be limited to a maximum of 25,000 square feet between 45 - 100 feet and a maximum of
10,000 square feet between 100 - 150 feet, but allows deviations to these floorplate requirements provided
the mass and scale of the design creates a tiered effect and complies with the maximum building envelop
allowance above 45 feet. The largest floorplate between 45 - 100 feet is approximately 48,212 square feet
and between 100 - 150 feet it is approximately 27,292 square feet. The applicant requests such deviations
to the floorplate restrictions. The Design Guidelines provide that no more than 60 percent of the theoretical
maximum building envelop located above 45 feet be occupied by a building. The applicant has calculated
the overall building mass between 45 - 150 feet at 38.0 percent, approximately two-thirds of the maximum
permissible.
Community Development Board - October 21, 2008
FLD2008-05013 - Page 8 of 14
Section C.1 requires buildings with a footprint of greater than 5,000 square feet to be constructed so that
no more than two of the three building dimensions in the vertical or horizontal planes are equal in length.
The proposed building footprint is approximately 96,110 square feet. The project's overall horizontal
plane dimensions are approximately 447 feet along South Gulfview Boulevard and 237 feet along the north
side, while the vertical plane is approximately 158 - 159 feet from grade to the top of the tallest roof.
None of these dimensions are equal. Modulation of the building massing also provides considerable
dimensional variation.
Section C.2 requires no plane or elevation to continue uninterrupted for greater than 100 feet without an
offset of more than five feet. Although the base extends nearly the length of the property, it is highly
articulated. Within 50 feet of the north and south ends of the building, the towers interface with the lower
structure as they reach the ground. To the east, the center of the base has structural fins that extend up
from the ground to support the building above the drop-off porte cochere and continue up to the roof of the
timeshare connector. To the west, the base is carved back to create the public palm court. The north side
is curved, creating a continuously curving facade and therefore, no plane is continuous for more than 30
feet. The two towers are oriented on an east-west axis, with the tower units angled for the occupants with
balconies to view the gulf, creating a saw tooth edge on both sides of the towers.
Section C.3 requires at least 60 percent of any elevation to be covered with windows or architectural
decoration. The applicant has calculated that the north elevation is at 65 percent, the east elevation at 68
percent, the south elevation at 60 percent and the west elevation at 71 percent.
Code Enforcement Analysis: There are no outstanding Code Enforcement issues associated with the
subject property.
Community Development Board - October 21, 2008
FLD2008-05013 - Page 9 of 14
COMPLIANCE WITH STANDARDS AND CRITERIA: The following table depicts the consistency
of the overnight accommodation use proposal with the standards as per Section Tables 2-801.1 and 2-803
of the Community Development Code:
Standard Proposed Consistent Inconsistent
Density 50 overnight accommodation units per 450 overnight X
acre (maximum of 137 units) accommodation units
(163.6 OVU/acre)i
I. S.R. 0.95 0.92 X
Lot Area 10,000 - 20,000 se 119,856 square feet (2.75 X
acres)
Lot Width 100 - 150 feet 545 feet along Coronado X
Dr.; 227 feet along
proposed 2nd St.
Setbacks Front: Zero - 15 feet East (along Coronado Dr): X3
Zero feet (to building and
pavement)
South (along proposed 2nd
St): 18.83 feet (to building)
North and West (along
South Gulfview Blvd):
Zero feet (to building)
Height 35 - 100 feet 150 feet (to roof deck) X3
Off-Street One space per room/unit (450 spaces Either 463 valet-only X3
Parking required) parking spaces (1.028
parking spaces per hotel
room) or 455 valet-only
parking spaces with eight
public parking spaces
(1.011 parking spaces per
hotel room)
i Per Termination of Status of Nonconformity of 200 units/rooms and 250 units/rooms from the Beach by Design density pool
2 Based on Overnight Accommodation use in the Tourist (T) District
3 See analysis in Staff Report
Community Development Board - October 21, 2008
FLD2008-05013 - Page 10 of 14
COMPLIANCE WITH FLEXIBILITY CRITERIA: The following table depicts the consistency of the
development proposal with the Flexibility criteria as per Section 2-803.C of the Community Development
Code (Comprehensive Infill Redevelopment Project):
Consistent Inconsistent
1. The development or redevelopment is otherwise impractical without deviations X1
from the use and/or development standards set forth in this zoning district.
2. The development or redevelopment will be consistent with the goals and policies of X'
the Comprehensive Plan, as well as with the general purpose, intent and basic
planning objectives of this Code, and with the intent and purpose of this zoning
district.
3. The development or redevelopment will not impede the normal and orderly X'
development and improvement of surrounding properties.
4. Adjoining properties will not suffer substantial detriment as a result of the X1
proposed development
5. The proposed use shall otherwise be permitted by the underlying future land use X'
category, be compatible with adjacent land uses, will not substantially alter the
essential use characteristics of the neighborhood; and shall demonstrate
compliance with one or more of the following objectives:
a. The proposed use is permitted in this zoning district as a minimum standard,
flexible standard or flexible development use,
b. The proposed use would be a significant economic contributor to the City's
economic base by diversifying the local economy or by creating jobs,
c. The development proposal accommodates the expansion or redevelopment of an
existing economic contributor,
d. The proposed use provides for the provision of affordable housing,
e. The proposed use provides for development or redevelopment in an area that is
characterized by other similar development and where a land use plan
amendment and rezoning would result in a spot land use or zoning designation;
or
f The proposed use provides for the development of a new and/or preservation of
a working waterfront use.
Community Development Board - October 21, 2008
FLD2008-05013 -Page 11 of 14
Consistent I Inconsistent
6. Flexibility with regard to use, lot width, required setbacks, height and off-street X'
parking are justified based on demonstrated compliance with all of the following
design objectives:
a. The proposed development will not impede the normal and orderly
development and improvement of the surrounding properties for uses permitted
in this zoning district,
b. The proposed development complies with applicable design guidelines adopted
by the City,
c. The design, scale and intensity of the proposed development supports the
established or emerging character of an area,
d. In order to form a cohesive, visually interesting and attractive appearance, the
proposed development incorporates a substantial number of the following
design elements:
? Changes in horizontal building planes;
? Use of architectural details such as columns, cornices, stringcourses,
pilasters, porticos, balconies, railings, awnings, etc.,
? Variety in materials, colors and textures,
? Distinctive fenestration patterns,
? Building stepbacks; and
? Distinctive roofs forms.
e. The proposed development provides for appropriate buffers, enhanced
landscape design and appropriate distances between buildings.
1 See analysis in Staff Report
COMPLIANCE WITH GENERAL STANDARDS FOR LEVEL TWO APPROVALS: The
following table depicts the consistency of the development proposal with the General Standards for Level
Two Approvals as per Section 3-913 of the Community Development Code:
Consistent I Inconsistent
1. The proposed development of the land will be in harmony with the scale, bulk, X'
coverage, density and character of adjacent properties in which it is located.
2. The proposed development will not hinder or discourage development and use of X'
adjacent land and buildings or significantly impair the value thereof.
3. The proposed development will not adversely affect the health or safety of persons X1
residing or working in the neighborhood.
4. The proposed development is designed to minimize traffic congestion. X'
5. The proposed development is consistent with the community character of the X1
immediate vicinity.
6. The design of the proposed development minimizes adverse effects, including X'
visual, acoustic and olfactory and hours of operation impacts on adjacent
1 See analysis in Staff Report
SUMMARY AND RECOMMENDATION:
The Development Review Committee (DRC) reviewed the application and supporting materials at its
meetings of June 5, 2008, and September 4, 2008, and deemed the development proposal to be sufficient to
move forward to the Community Development Board (CDB), based upon the following findings of fact and
conclusions of law:
Findings of Fact:
Community Development Board - October 21, 2008
FLD2008-05013 - Page 12 of 14
I . The 2.75 acres is located directly south of Pier 60 between Coronado Drive and South Gulfview
Boulevard, north of Second Street;
2. On October 19, 2004, the Community Development Board (CDB) approved a Flexible Development
application for the construction of a 350-unit hotel with associated amenities and 75 attached dwellings
as a mixed-use development (FLD2004-02013). The City Council approved a companion
Development Agreement on February 17, 2005 (Case No. DVA2004-00001);
3. On May 17, 2005, the CDB approved a Flexible Development application amending the prior project
to modify the location of an elevated pedestrian walkway over South Gulfview Boulevard (FLD2004-
02013A);
4. On March 16, 2006, City Council approved an amendment to this original Development Agreement
(DVA2004-00001A), which dealt with issues associated with Beach Walk construction and the timing
of the dedication of land for Relocated 1St Street (to be known as Second Street once constructed), as
well as for the construction of Relocated 1 st Street;
5. The properties were previously developed with various motels (Days Inn, Beach Towers Motel,
Spyglass Motel and Golden Beach Motel) and numerous retail sales and restaurant uses. All of the
buildings containing these uses have been demolished;
6. The subject property is currently vacant, but used as a temporary City public parking lot;
7. The nonconforming status of the prior 200-unit hotel density has been determined to still be valid, even
though all of the motels/hotels have been demolished, due to the status of the approval of Case Nos.
FLD2004-02013/DVA2004-00001;
8. The proposal is to redevelop the site with a 450-unit/room destination resort hotel, consisting of 250
traditional hotel units and 200 vacation/interval ownership (timeshare) units and including amenities
accessory to the hotel of a restaurant, lounge, retail sales, pool, spa, ballroom and meeting space;
9. The proposal eliminates the approved pedestrian bridge to Clearwater Beach, instead providing for the
construction of a loggia and a palm court pedestrian area on the west side;
10. The building mass consists of a four-story base, two 150-foot towers and a 95-foot tall connecting
element that links the towers and base together;
11. The proposed hotel consists of four rooftop levels - one being the amenity deck at 38.67 feet; the spa
on the north end of the hotel tower at a height of 48.17 feet; the third being the connector element
between the two towers at a height of 95 feet; and the fourth being the hotel and timeshare towers
having a height of a maximum of 150 feet to the flat roof deck;
12. That portion of the building exceeding 100 feet in height is separated from the Aqualea/Hyatt building
to the south by 140.67 feet, exceeding the Beach by Design minimum requirement of a 100-foot
separation;
13. Parking for the hotel guests and employees is provided in a parking garage on three levels containing
463 valet-only parking spaces or 455 valet-only parking spaces with eight public parking spaces at
1.028 or 1.011 parking spaces per hotel room, respectively, which will be 100 percent valet parked;
14. Of the 463 parking spaces provided, 162 spaces are designed as stacked or tandem spaces where
another car must be moved to get the stacked or tandem car out;
15. This site was originally granted 250 hotel rooms from the hotel density pool created by Beach by
Design under Case Nos. FLD2004-02013/DVA2004-00001;
16. The proposal includes a front (east along Coronado Drive) setback of zero feet (to building and
pavement), a front (south along proposed Second Street) setback of 18.83 feet (to building) and a front
(west and north along South Gulfview Boulevard) setback of zero feet (to building);
17. The application includes a request for deviations to the floorplate restrictions;
18. There are no outstanding Code Enforcement issues associated with the subject property.
Conclusions of Law:
Community Development Board - October 21, 2008
FLD2008-05013 - Page 13 of 14
1. That the development proposal is consistent with the Standards as per Section 2-801.1 and Table 2-803
of the Community Development Code;
2. That the development proposal is consistent with the Flexibility criteria as per Section 2-803.C of the
Community Development Code;
3. That the development proposal is consistent with the General Standards for Level Two Approvals as
per Section 3-913 of the Community Development Code;
4. That the development proposal is consistent with the Design Guidelines of Beach by Design; and
5. The proposal is compatible with the adjacent land uses.
Based upon the above, the Planning Department recommends APPROVAL of the (1) Flexible
Development application to Terminate the Status of a Nonconformity for density (200 overnight
accommodation units; where 137 overnight accommodation units are permitted today) within the Tourist
District, under the provisions of Section 6-109.C; (2) Flexible Development approval to permit a 450-unit
Overnight Accommodation use (through an increase of the permitted density of 250 overnight
accommodation units from the density pool created pursuant to Beach by Design), with a lot area of
119,856 square feet (2.75 acres), a lot width of approximately 545 feet along Coronado Drive and 227 feet
along proposed Second Street, a front (east along Coronado Drive) setback of zero feet (to building and
pavement), a front (south along proposed Second Street) setback of 18.83 feet (to building), a front (west
and north along South Gulfview Boulevard) setback of zero feet (to building), a building height of 150 feet
(to roof deck) and either 463 valet-only parking spaces or 455 valet-only parking spaces with eight public
parking spaces at 1.028 or 1.011 parking spaces per hotel room, respectively, as well as the allowance of a
two-year time frame to submit for a building permit, as a Comprehensive Infill Redevelopment Project,
under the provisions of Section 2-803.C; (3) To reduce the required foundation landscaping along
Coronado Drive and S. Gulfview Boulevard from five to zero feet (to building and pavement), as a
Comprehensive Landscape Program, under the provisions of Section 3-1202.G; and (4) Vacation of a
portion of S. Gulfview Boulevard (former bridge landing), with the following conditions:
Conditions of Approval:
1. That approval of this Flexible Development case is subject to the approval of an amended Development
Agreement with the City (Case DVA2008-00001);
2. That approval of this Flexible Development case is subject to the vacation of the pedestrian bridge
landing right-of-way by the City prior to the issuance of any permits;
3. That the final design and color of the building be consistent with the conceptual elevations approved by
the CDB;
4. That application for a building permit to construct the approved project be submitted no later than
October 21, 2010, unless time extensions are granted pursuant to Section 4-407;
5. That a Declaration of Unity of Title for Condominiums be recorded in the public records prior to the
issuance of any permits;
6. That any structures permanently affixed to the roof of the timeshare connector between the two towers
or south of the timeshare tower that permit rooftop occupancy be only permitted if such structures are
within the maximum allowable height of 100 feet above BFE (five feet above the designed 95-foot
height of the roof of the timeshare connector);
7. That sea-turtle friendly light fixtures be employed with the site design, with compliance demonstrated
on plans acceptable to the Environmental Engineering Division, prior to the issuance of building
permits;
8. That, prior to the issuance of the building permit, the vertical clear height of all the parking garage
levels be not less than 7 feet including entrance and exit (Florida Building Code 2004, Section
406.2.2);
Community Development Board - October 21, 2008
FLD2008-05013 - Page 14 of 14
9. That any future freestanding sign be a monument-style sign and be designed to match the exterior
materials and color of the building. The maximum height shall be four feet, unless approved at six feet
high through a Comprehensive Sign Program;
10. That, prior to the issuance of the Certificate of Occupancy, an easement be recorded in the public
records for the sidewalk along Second Street partially on the subject property;
11. That, prior to the issuance of any permits, compliance with all requirements of General Engineering,
Traffic Engineering and Stormwater Engineering be met;
12. That any applicable Public Art and Design Impact Fee be paid prior to the issuance of any permits;
and
13. That all Parks and Recreation fees be paid prior to the issuance of any permits.
Prepared by Planning Department Staff:
Wayne M. Wells, AICP, Planner III
ATTACHMENTS:
? Location Map
? Aerial Map
? Zoning Map
? Existing Surrounding Uses Map
? Photographs of Site and Vicinity
S: )Planning DepartmentlC D BIFLEX (FLD) )Pending cases) Up for the next CDBICoronado 0100 Clearwater Beach Resort & Hotel (T) -
10.21.08 CDB - WWICoronado 0100 StaffReport - 10.21.08 CDB. doc
Community Development Board - October 21, 2008
FLD2008-05013 - Page 15 of 14