PERMIT NUMBER DC52-26605 FOR MODIFICATON OF 5.0 MGD ACTVATED SLUDGE BY ADDITION OF 2 AUTOMATIC BACKWASH SAND FLTERS WTH CHORINATED EFFLUENT DISCHARGED TO OLD TAMPA BAY
POOR
ORIGINAL
I
J
7801 HIGHWAY 301 NORTH
TAMPA, FLORIDA 33810
BOB GRAHAM
GOVERNDR
JACOB D. VARN
SECRETARY
DAVID PUCHATV
DISTRICT MANAGER
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL REGULATION
SOUTHWEST DISTRICT
February 4, 1980
Mr. Anthony L. Shoemaker
City of Clearwater
P.O. Box 4748
Clearwater, FL 33518
Pinellas County
Clearwater East
PCF . . fI " ^ P
QJLP~ - 1:iA
V ct,P.~
(ll' c!;lj t) I~
Dear Mr. Shoemaker:
Enclosed is Permit Number DC52-26605 , dated Feb. 4, 1980 ,
to construct
issued pursuant to Section 403.087 , Florida Statutes.
Should you object to this permit, including any and all of the con-
ditions contained therein, you may file an appropriate petition for
administrative hearing. This petition must be filed within fourteen
(14) days of the receipt of this letter. Further, the petition must
conform to the requirements of Section 28-5.15, Florida Administrative
Code, (see reverse side of this letter). The petition must be filed
with the Office of General Counsel, Department of Environmental
Regulation, Twin Towers Office Building, 2600 Blair Stone Road,
Tallahassee, Florida 32301.
If no petition is filed within the prescribed time, you will be deemed
to have accepted this permit and waived your right to request an
administrative hearing on this matter.
Acceptance of the permit constitutes notice and agreement that the
Department will periodically review this permit for compliance,
including site inspections where applicable, and may initiate
enforcement action for violation of the conditions and requirements
thereof.
cc: TBRPC
FPSC
Richard
Records
Sincerely,
~
aV1d pucha~
District Manager
Southwest District
~
Enclosure
DER Form 17-1.122 (66) paqe 1 of 2
PDP/err
RULES; OF THE ADMINISTRATIVE COMMISSION
MODEL RULES OF PROCEDURE
CHAPTER 28-5
DECISIONS DETERMINING SUBSTANTIAL INTERESTS
28-5.15 Requests for Formal and Informal Proceedings
(1) Requests for proceedings shall be made by petition to the
agency involved. Each petition shall be printed typewritten
or otherwise duplicated in legible form on white paper of
standard legal size. Unless printed, the impression shall
be on one side of the paper only and lines shall be double
spaced and indented.
(2) All petitions filed under these rules should contain:
I
(a) The name and address of each agency affected and each
agency's file or identification number, if known;
(b) The name and address of the petitioner or petitioners;
(c) All disputed issues of material fact. If there are none,
the petition must so indicate;
(d) A concise statement of the ultimate facts alleged, and the
rules, regulations and constitutional provisions which
entitle the petitioner to relief;
(e) A statement summarizing any informal action taken to
resolve the issues, and the results of that action;
(f) A demand for the relief to which the petitioner deems
himself entitled; and
(g) Such other information which the petitioner contends is
material.
DER Form 17-1.122(66) Page 2 of 2
,
I
.~
'"'.:-~ .-,..
I
:~
~~l
''-""... ClI' ftI:II-.'-
I
BOB GRAHAM
GOVERNOR
JACOB D. VARN
SECRETARY
DAVID PUCHATY
DISTRICT MANAGER
'.
7601 HIGHWAY 301 NORTH
TAMPA, FLORIDA 33610
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL REGULATION
SOUTHWEST DISTRleT
APPLICANT:
Mr. Anthony L. Shoemaker
City of Clearwater
P.o. Box 4748
Clearwater, FL 33518
PERMIT/CERTIFICATION
NO. DC52-26605
COUNTY: pinellas
PROJECT: Clearwater East PCF
This pe[r1Jjt i~ issued under the provisions of Chapter 403.087 , Florida Statutes, and Chapter
..L /- 4 , Florida Administrative Code. The above named applicant, hereinafter called Permittee, is hereby authorized to
perform the work or operate the facility shown on the approved drawing(s). plans, documents, and specifications attached hereto and
made apart hereof and specifically described as follows:
Modification of a 5.0 MGD activated sludge wastewater treatment plant by
the addition of two automatic backwash sand filters with chlorinated
effluent"discharged to Old Tampa Bay.
Location:3141 Gulf to Bay Boulevard (S.R. 60)
Clearwater, Florida
Latitude: 270 571 40"
Longitude: 820 491 40"
Inf.Sta.No.: 2404-2101
Eff.Sta.No.: 2404-2102
Segment No.: 24.4 EA
Station ID No.: 52 M 00691
1 4
PAGE OF
DEA FOAM 17-1.122(63) 1/4 (1/801
"
1 t,.
PERMIT NO.:
APPLICANT:
DC52-26605
Mr. Anthony L. Shoemaker..
GENERAL CONDITIONS:
1. The terms, conditions, requirements, limitations, and restrictions set forth herein are "Permit Conditions:, and as such are bind,
ing upon the permittee and enforceable pursuant to the authority of Section 403.161(1), Florida Statutes. Permittee is hereby placed
on notice that the department will review this permit periodically and may initiate court action for any violation of the "Permit Con-
ditions" by the permittee, its agents, employees" servants or representatives.
2. This permit is valid only for the specific processes iindoperations indicated in the attached drawings or exhibits. Any unautho-
rized deviation from the approved drawings, exhibits, specification1i, or conditions of this permit shall constitute grounds for revoca-
tion and enforcement action by the department.
3. If, for any reason, the. permitt8e does. not comply with or will be unable to comply with any condition or limitation specified in
this permit, the "ermittee shall immediately notify .and j)rovide the department with the following information: (a) a description of
and cause of non-compliance; and (b) the period of non-compliance, including exact dates and times; or, if not corrected, the antici-
pated time the non-compliance is e>Epected to continue, and steps being taken to reduce, eliminate, and prevent recurrence of the non-
compliance. The permittee shall be responsible for any and all damages which may result and may be subject to enforcement action by
the department for penalties or revocation of this permit.
4. As provided in subsection 403.08.7(6), Florida Statutes, the issuance of this permit does not convey any vested rights or any ex-
clusive privileges. Nor does it authorize any injury to public or private property or' any invasion of personal rights, nor any infringe-
ment of federal, state or local laws or regulations.
5. This permit is required to be posted in a tonspicuous location at the work site or source during the entire period of construction
or operation.
6. In accepting. this permit, the permittee understands and C\grees that all records, notes, monitoring data and other information re-
lating to the construction or OPeration of this permitted source, which are submitted to the department, may be used by the depart-
ment as evidence in any enforcement ca.se arising under the Florida Statutes or department rules,exceptwhere such use is proscribed
by Section 403,111, F.S.
7. In the case of an operation permit, permittee agrees to comply with changes in department rules and Florida Statutes after a
reasonable time for compliance, provided, however, the permittee does not waive any other rights granted by Florida Statutes or de-
partment rules.
8. This permit does not relieve the permittee from I iabi.1 ity for harm or injury to human health or Welfare, animal, plant, or aquatic
life or property and penalities therefore caused by the construction or operation of this permitted source, nor does it allow the per-
mittee to cause pollution in contravention of Florida Statutes and department rules, except where specifically authorized by an order
from the department granting a variance or exception from department rules or state statutes.
9. This permit is not transferable. Upon sale or legal transfer of the property or facility covered by this permit, the permittee shall
notify the department within thirty (30) days. The new owner must apply for a permit transfer within thirty (30) days. The permittee
shall be liable for any non-compliance of the permitted source until the transferee applies for and receives a transfer of permit,
10. The perm ittee, by acceptance of this permit, specifically agrees to allow access to perm itted source at reasonable times by de,
partment personnel presenting credentials for the purposes of inspection and testing to determine compliance with this permit and
department rul.es.
11. This perm it does not indicate a waiver of or approval of any other department permit that may be requ ired for other aspects of
the total project.
12. Th is perm it conveys no title to land or water, nor constitutes state recognition or acknowledgement of title, and does not consti,
tute authority for the reclamation of submerged lands unless herein provided and the necessary title or leasehold interests havo huon
obtained from the state. Only the Trustees of the Internal Improvement Trust Fund may express state opinion as to title,
13. This permit also constitutes:
[ ] Determination of Best Available Control Technology (BACT)
[ ] Determination of Prevention of Significant Deterioration (PSD)
[ ] Certification of Compliance with State Water Quality Standards (Section 401, PL 92-500)
2 4
PAGE _OF_.
DER.FORM17-1.122(63) 2/4 (1/80)
1
I
~
..
I
I
'.
.
PERMIT NO.: DCS2-2660S
APPLICANT: Mr. Anthony L. Shoemaker
Specific Conditions:
1) The compliance schedule for this source is:
Completion of 'Operational Analysis and Full Compliance - January 31,1983
2) The discharge limits for BODS and suspended solids during the term of
of TOP are:
BODS and Suspended Solids - 82S#/day
Ultimate disposal shall be in accordance with the Central Pinellas 201
Facilities Plan.
3) Monitoring shall be provided in accordance with Chapter 17-19 F.A.C.
Expiration Date: November 21, 1980
Issued this ~ day of t:eb.,.~ ,19~.
cc : TBRPC
FPSC
Richard B. Gassett,
Records Center
STATE OF FLORIDA
DEPARTMENT OF ENV~TAL REGULATION
P~~.
. avid Puchaty
District Manager
DER FORM 17-1.122(63) P8g8, 3 013
PDP/err