Loading...
PERMIT DC52-2515 FOR CONSTRUCTION OF POLLUTION SOURCE ~ tN~1 STATE OF FLORIDA DEPARTME'T OF ENVIRONMENTAL REGULATION I RECEIPT FOR APPLICATION TO OPERATE/CONSTRUCT POLLUTION SOURCES ~ n.t f'h/lAll/(:rH-<.) o.te /Yl.AALAJ.,2, /9 f ~.I~ (lJ/AA.L/~'/./A) r;1/.d. 3a5/? Dollars $ 8r:J. rfJD / I , t4AHlt/v {if!, 5"tP ~ 0104 r-' (J~~ By REUBIN 0'0 ASKEW GOVERNOR I ,'"., JfLII Wit;ll.Ufu tW~ilIt~ STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL REGULATION SOUTHWEST DISTRICT 9721 EXECUTIVE CENTER DRIVE. NORTH, SUITE 200 !l:~)frl~ ST. PETERSBURG. FLORIDA Ja~ 33702 March 9, 1976 Pinellas County DW Clearwater Northeast PCF JOSEPH W LANDERS. JR seCRETARY Mr. Picot B. Floyd City Manager City Hall Clearwater, Florida 33518 Dear Mr. Floyd: Pursuant to your recent application, please find enclosed a permit (No.DC52-2516) dated 3/9/76 to construct~ the subject pollution source. This permit will expire on 12/30/78, and will be subject to the conditions, requirements and restrictions checked or othcr~ise indicated in the attached sheet "Construction/~ Permit Conditions". This permit is issued under the authority of Florida Statute 403.061(16). The time limits imposed herein are a condition to this permit and are enforceable under Florida Statute 403.161. You are placed on Notice that the Department ~i1l review this permit before the scheduled date of expiry and will seek court action for violation of the conditions and requirements of this permit. You have ten days from Lhe date of receipt hereof within which to seek a review of the conditions and requirements contained in this permit. Failure to file a written request to review or modify the conditions or requirements contained in this permit shall be deemed a waiver of any objections thereto. Your continued cooperation in this matter is appreciated and in future communication please refer to your permit number. B~/ AP/smw ~c:~entral Files J. F. Dennis, P.E. Tampa Bay Regional Planning Council Sincerely, Ba~e~t.~d District Manager Southwest District ....'. .. ,-'), ',').j ;' t )C I I . ~ ... ~... ~... ~... ~... ~... ~... ~... ...... ~ ... ~... ~... ~ ... ... ... ~... ~ ... ... ... ",', ... ~... ~... ...... ...... ...... ~ ... ...... ~ ... ...... ~ ...' STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL REGULATION CONSI:RMeTION PERMIT , ,,',., ,>:, :/""-'''", ", "; ;:,::,:; ""':~":" ,:::;:;pf','",'''' fClearwater PCF) d'!i PERMITNO. DC 52-2516 ) . ' DATE OF ISSUE March~;~> 1976 "I 'i,::' ,','" ::'''. '(,,,, , PURSUANT TO THE PROVISIONS OF SECTIONS 403.061(16) AND 403.707 OF CHA~~~ 4~FLORIDA STATUTES AND CHAPTERS 17-4 AND 17-7FLOA;IDA ADMINISTRATIVE CODE, THIS PERMIT ISf~\JED TO: Mr,.'Picot Floyd, City~~n~ger ii' ., "',:.,i !ctivatedSl,u.dge Sewag~ chlorinated effluent.b .~ .' . : .1. .; East of McMullen }!~6th r' d IN ACCORDANCEWITrl THE AP1"LICATIONDAT:13li!'l:(l~~~9'a ty 16, 1976 ,"1"0;.";,,' ,.'< ";'1 ,~i'< 0"" ANY CONDITIONS OR PROVISOS WHICH AIJE'ATk EQ.HERI;!TO ARE INCORPORATED INTO AND MADE A .; PARk OF THIS PERMIT AS THOlJQt-l FULLY SEt U'RTH HEREIN. FAILURE TO COMPLY WITH SAID CONDITIONS OR PROVISOS SHALL cONs1;lT~"~'t,YIP~.ATION OF THIS PERMIT AND SHALL SUBJECT THE APPLICANT TO SUCH CIVIL AND CRIMINAL PENALTIES AS PROVIDED BY LAW. THIS PERMIT SHALL BE EFFECTIVE FROM THE DATE OF ISSUE UNTIL December 3 0, 1978 ...y~ '.........~......................~...~...~...~.........~...~...~...~...~...............~...~ DER FS 7 8/75 I I STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL REGULATION CONSTRUCTION PERMIT CONDITIONS DOMESTIC (MUNICIPAL) WASTE SOURCES PERMIT # DC 52-2516 DATE March 9, 1976 (X) 1. Construction of this installation shall be completed by 6/30/78 (X) 2. This construction permit expires on 12/30/78 ,following an initial period of operation for appropriate testing to determine compliance with the Rules of the Florida Department of Environ- mental Regulation. (X) 3. All applicable rules of the Department including design discharge limitations specified in the application shall be adhered to. The permit holder shall also comply with county, municipal, federal or other state regulations prior to construction. (X) 4. The applicant shall continue the retention of the engineer of record for the inspection of the construction of this project. Upon completion the engineer shall inspect for conformity to construction permit applications and associated documents. A report of such inspection shall be submitted by the engineer to the Department of Environmental Regulation for consideration toward the issuance of an operation permit. (X) 5. This construction permit is issued with the understanding that there will be no discharge to area surface waters and that all plant effluent will be retained on the owner's property~ (or to deep well at a site to be determined). () 6. The evaporation-percolation/polishing pond shall be enlarged as necessary and sufficiently maintained to insure against discharge to area surface waters. Two shallow sampling wells will be installed located in the watertable, hydraulically downstream from the pond (ref. Chapter 17-19.08 FAC). eX) 7. The STP's treatment process shall include design features which will result in total compliance with Chapter 17-3 of the Florida Administrative Code, which requires 90% or better reduction in BOD (5-day) and Suspended Solids. (X) 8. The chlorine residual in the effluent must be maintained at (~xix~~~ (1.0 ppm) minimum, after 15 minutes contact, at maximum flow. (X) 9. If found to be necessary for protecting downstream/receiving waters, tertiary treatment for nutrient removal and/or additional BOD reduction shall be provided. PbkMIT It DC 52-25161 I (x) 10. This construction permit is issued with the understanding that there are no water supply wells closer than 100 feet from the effluent disposal area which would be endangered. (X) 11. Construction for expansion to a larger capacity shall not be initiated prior to application to and permitted by the DER. ( ) 12. When an areawide district/metropolitan collection and treatment system becomes available, the DER will require the permittee to connect the source to such a system within a specified period of time. It will then be incumbent upon the permittee to comply with such requirements, cease operation of the permitted source and remove the permitted plant from its site. (X) 13. Before an operation permit is issued, the applicant shall submit evidence that an operator certified under Chapter 17-16 Florida Administrative Code is retained for day-to-day maintenance and operation of the treatment facilities. This plant will be classified as a Level II, Class A plant. As such, it will require that a Class x-operator be-on site 24 hours/day, 7 da s week -- en app Ylng or an operatIon permIt, provI e name an icate number of plant operator. (X) 14. The following characteristics of the wastewaters shall be tested (ref. Chapter 17-19 FAC). PARAMETER SAMPLING POINT FRE UENCY Influent E fluent In luent & E' luent In luent & Eluent Eluent Eluent Eluent Eluent E uent uent luent luent lnlmum samp lng perlo 24 hours, composited at hourly intervals (flow proportioned) A sufficient number of results of analyses and flow measurements to substantiate compliance with applicable provisions of the Florida Administrative Code shall be provided this Department prior to the issuance of an operation permit. Continuous Continuous Dail Dail Con tinuous X ee ly Initial test results are to be received no later than six weeks after the treatment plant has been placed in operation. These results shall be submitted, on a monthly hasis, the the DER Southwest District Office, 9721 Executive Center Drive North, Suite 200, St. Petersburg, Florida 33702. ( ) 15. Collection system related to this project IS hereby approved. I I PERMIT #DC 52-2516 (X) 16. Parameters listed in condition (14) are subject to change and will be finalized by the time applications are received for an operation permit. (X) 17. Operation Permit No. DO 52-2126 is hereby revised by changing its expiration date to December 30, 1978 in order to coincide with the expiration date of this construction permit. .-,~ ! . ' ,. I I D.- E. R. "~J ; j I q^R 2 ~ ,) I i STATE OF FLORIDA .suUfH WEST DISTRiCt DEPARTMENT OF EN'iIRONMENTAL REGULATlOrJT... ~ET"URG . -'APPLlCATI'ON TO Qlf(~CO-NSTRUCT ll~X)QVMUN c W ASTEW ATER POLLUTION SOURCES TO BE FILLED IN BY APPLICANT Type application: Status Source: [ ] Operation [x] New [ ] Temporary Operation [ ] Existing [x] Construction [ ] Modification Source Name: Clearwater Northeast Wastewater Treatment Faci I ity County: Pi nellas Road Source Location: Street: North of S.R. 580, East of McMullen Booth City: Clearwater (Water Source Only) Lat: 28 01 15 Long: 82 42 00 (Air Source Only) UTM: East North Appl. Name and Title: Appl. Address: City of Clearwater City Hall , Clearwater. Florida 33518 II TO BE FILLED IN BY REGION (*BY BUREAU OF PERMITTING) Control No: Region County Type *Project .. --4 Type P~rmit Date Rec'd *Permit No. *Issue Date *Compl. Date *Exp. Date Source Description: Control Equipment: Receiving Body Code: Station No.: Influent: Water Pennits Surface Water Code: Effluent: Effluent: Average Design %.Reduction Flow rate, MGD BOD,lbs!day Susp. SoL, Ibs/day Other: Air Pennits Crrating Time: [] Continuous hel: Type Incinerator: Capacity, tons/day Mfg. & Model Pollutant Emissions,lbs/day Actual Particulate Sulfur Oxides Other: [ ] Intermittent M-BTU/hr. In Put Type Waste Design Allowable = Implementation: Estimated AppL Filing Date Estimated Start of Const. Estimated Compliance Date J I I DESCRIPTION OF PROPOSED PROJECT A. Describe the nature and extent of the proposed project. Refer to existing pollution control facilities. DER permits, conditions, orders and notices, expected improvement in performance of the facilities and state whether the proposed project will result in full compliance of the source. Attach additional sheet if necessary. The Clearwater Northeast Wastewater Treatment Facility will provide capacity to process an avera!:le of 8 MGD of raw wastewater to the required de!:lree of secondary treatment. The plant wi II include mechanical screenin!:l, aerated !:lrit removal, odor control, primary clarification. conventional activated sludge. secondary clarification and disinfection processes. Sludges.will be digested aerobically and beneficially applied to the land in a controlled manDer for fertilization and soil conditionin9 Durposes. The project will provide the required dearee of treatment preparatorv to effluent disposal by deep well injection; the plannina. desian and construction of which will roceed concurrentl with the construction of the subject treatment system. T e project will result in full compliance of the source. B. Schedule of Project Covered in this Application (Construction Permit Application Only). Federally or State Financed Projects only: Planning Complete December , 1975 Financing Program Complete February, 1976 Indicate other local, state and/or federal agency approvals and dates FDER project certification-December 17. 1975 All projects: Start of Construction June, 1976 Completion of Construction 730 days C. Costs of Construction (Show a breakdown of costs for individual components/units of the proposed project serving pollution control purpose only}. Information on actual costs shall be furnished with the application for operation permit. Wastewater Treatment Facit ity $6.250.000 D. Innicate any previous DER permits, issuance dates, and expiration dates. E. Indicate the relationship between this project and area regional planning for sewage treatment. List steps to be taken for this sewage treatment plant to become part of an area wide sewerage system. The project is in compliance with the Regional Water Quality Management Plan as developed by the Tampa Bay Regional Planning Council. The proiect will provide service to the nearby City of Safety Harbor. fS36-2 OJ .~ I I DOMESTIC W ASTEW A TER TREATMENT PROCESS A. General 1. Present Population: 2. Population Served by Existing Plant: 3. ~ew Design Population to be Served: 4. Present Approved Capacity of Plant: 5. New Design Capacity Proposed: B. Wastewater Treatment Process 74.000 estimated City-wide 2.000 80.000 MGD 8 MGD 1. Describe treatment process and identify treatment units: Mp.chanicaI screening. aerated Qrit removal, primary clarification, conventional activated sludge. secondary clarification, and disinfection. 2. Advanced Waste Treatment: Not Applicable [ ] Nitrogen Removal [ ) Phosphate Removal [ ] BOD/Suspended Solids Removal [ ] Other C. O1Iorination Points of Application: Contact chamber, raw wastewater, !:Iri t chamber em uent. Chlorine Dosage: 1.5 to 30'mQIL with laraest chlorinator out of service. D. List sludge treatment units: Aerobic diqestion and !:Iravity thickenin!:l E. Volume, Composition, and Site and Method of Ultimate Disposal of Sludge (provide name and address of carrier, if applicable.) Di!:lested slud!:le at 30,800 !:Ipd and about 3% solids will be land spread on parks, fields and golf courses totalling about 390 acres. F. Mcthod(s) and location(s) of flow measurement Venturi - type flow meterinq located between the !:Irit chambers and the primary settlin!:l to n ks . G. Describe practices to be followed to insure adequate treatment and disinfection during emergencies such as power and equipment failures. Dual power supply from two separate substations has been orovided. All critical process and equipment units have been provided at least in duolicate. FS36-3 3 '-' I I ,"~ "" DOMESTIC W ASTEW A TER CHARACTERISTICS Information furnished in this section for Construction Permit shall be based on reasonable prediction and good professional judgment. However. actual data shall be submitted when applying for an operation permit. A. Flow (MGD) Average 8 MGD B. Water Quality Characteristics Parameter Inf1uent Emuent Per Cent ppm (Before Chlorination) Removal I ppm Ave. Design lbs./day Ibs.fday 5-day BOD 210 20 1.340 1 335 90+ Total Solids: Total: 850 600 40 000 ----- 29 Volatile: 650 450 30,000 ----- 31 Suspended Solids: Total: 210 20 1.340 1 335 90+ Volatile: 160 15 1.000 1.000 90+ Total Nitrogen (N)* Total Phosphorus (P)* . Other: I *This requirement, if necessary, will be specified in construction permit. C. Average Chlorine Residual in Effluent 1.0 ppm D. List industrial wastes, if any, treated in combination with domestic wastes: None 1=536-4 4 ~, I I ULTIMATE EFFLUENT DISPOSAL (See note, page 6) A. Type of Receiving Body J. Surface waters: Fresh Salt or Brackish I ] I [ ] 2 2. Ground Waters: Surface or Sub-surface Irrigation Ponding and Percolation Recharge Wells Deep Well Injection Evaporation to Atmosphere [ ] 6 3 4 5 x 3. B. If discharge is to surface waters complete the following: Not Applicable 1. Drainage Ditch [ ] I Small Stream [ ] 5 River [ ] 2 Man.made Canal [ ] 6 Landlocked Lake [ ] 3 Lake with Outlet [ ] 7 Tidal Estuary [ ] 4 Ocean or Gulf [ J 8 2. Identify and describe the drainage path of effluents to major body of water: 3. Use and Florida's Water Quality Classification of the Receiving Waters: C. Description of Outfall to Area Surface Water Not Applicable I. Approximate Water Depth at Outfall During Low Flow: 2. Approximate Depth Below Outfall Invert: 3. Diameter of Outfall: 4. Approximate Length of Outfall from Shoreline: D. If discharge into ground waters is involved during treatment or disposal, furnish the following information. 1. Surface or Sub.surface Irrigation Not Applicable a) Description of Disposal Structme(s) b) Area Under Irrigation Total: Per Rotation: c) Irrigation Rate: d) Percolation Rate: e) Ultimate Disposal of Surface Sub-surface Runoff FS36-S 6 -' I I t) Cover Crop: g) Number and Locations of Groundwater Monitoring Wells: 2. Seepage Ponds Not Applicable a) Area of the Pond{s): b) Depth of Water in the Pond: c) Percolation Rate: d) Indicate if there will be any overflow during rainfall: e) Groundwater table elevation in relation to pond bottom: t) Number and locations of groundwater monitoring wells: E. Environmental Data on Pollution Source Site is relatively isolated from residential or other Character of Area Within One Mile of Plant: r1l'!vl'!lnpmp.nt. Closest residence is about 1,000 feet south Qf main processin!=l are.a. . . Distancefrom the Nearest Municipality: site is approximafely J miles north of City of Safety Harbor. Owner of Land (if different from applicant): Owned bv appl i cant Availability of space for expansion of plant: Site has ample space for future expansion Indicate the number of (potable) water supply wells within 500 feet of efnuent disposal area, the depths of these wells and their approximate distances from the disposal area: FS36-6 6 "'" ..... I I CERTlFICA TION OF COMPLETION OF CONSTRUCTION Domestic/Industrial Wastewater Treatment and Disposal Systems (for Application to Operate Only) DER Project No.: County: Name of Project: Name of Owner: Name of Engineer: Scope of Project: Cost: Estimated S Actual Plant Design: Flow: gpcd MGD PopulatIOn No. of Connections Deviations from Plans Approved by the DER Effluent Drainage Path from Plant: Address & Telephone No. of Plant Name(s) of Operator(s): Date Plant Placed in Operation: This is to certify that, with the exception of deviations noted above, the construction of the project has been cllmpkted in accordance with the plans authorized by Construction Permit No,: Dated Date: Signature of PrllJcct Engllleer FS36-7 7 '"'" .....~ . I I STATEMENTS BY APPLICANT AND ENGINEER A. Applicant The undersigned owner or authorized repre;entative of * The Ci ty of CI ea rwa ter is fully aware that the statements made in this application for a construction permit are true, correct and complete to the best or his knowledge and belief. Further, the undersigned agrees to maintain and operate the pollution source and pollution control facilities in such a manner as to comply with the provisions of Chapter 403 Florida Statutes and all the rules and regulations of the Department or revisions thereof. He also understands that a permit, if granted by the Department, will be non-tra erable and he will promptly notify the Department upon sale or legal transfer of the permitted establishment. o the Owner or Authorized Representative _ Picot B Floyd. City ManaQer Name and Title (please Type) Date:IbJ M /6 197 b * Attach a letter of authorization V / Telephone No.: 813/442-6131 B. Professional Engineer Registered in Florida: This is to certify that the engineering features of this pollution control project have been designed/examined by me and found to be in conformity with modern engineering principles applicable to the treatment and disposal of pollutants characterized in the permit application. There is reasonable assurance, in my professional judgment, that the pollution control facilities, when properly maintained and operated, will discharge an effluent that complies with all applicable statutes of the State of Florida and the rules and regulations of the Department. It is also agreed that the undersigned will furnish the applicant a set of instructions for the proper maintenance and operation of the pollution control facilities and. if applicable, pollution sources. .. S;gn""" ~~- ~ 7t...,(Jo- Name: Steven E. Thayer (please type) Mailing Address: Bri lev, Wild .g. Associates P.O. Box 607 Ormond Beach, Florida 32074 Telephone No.: 904/672-5660 Florid:: Registration Number (please affIx seal) 18055 Date: ,-;,,~ j 9 1976 ) FS36-8 8 (J~ ...JLNj(0 ~. I I STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL REGULATION SOUTHWEST DISTRICT 9721 EXECUTIVE CENTER DRIVE, NORTH, SUITE 200 ~.~~~~P2~~ ST. PETERSBURG, FLORIDAX3U~ 33702 REUB IN on ASKEW GOVERNOR JOSEPH W LANDERS. JR. SECRET ARY March 9, 1976 Pinellas County DW City of Safety Harbor Mr. James W. Macfarlane Franklin Engineering, Ltd. 2630 West Bay Drive Belleair Bluffs, Florida 33540 Dear Mr. Macfarlane: We are in receipt of your request for an extension of the Temporary Operation Permit for the subject project. Based on the information submitted, we are hereby extending the expiration date of the Temporary Operation Permit No. TP 52-2340 from April 1, 1976 to December 30, 1978. A permit has been issued to the City of Clearwater to expand their present 1.0 MGD facility to 8.0 MGD. Construction completion is scheduled for June 30, 1978 with permit expiration set at December 30, 1978. It is recommended that the implementation schedule submitted with your request be slightly accelerated in order for construction completion of connecting transmission facilities to coincide with completion of plant construction and full phase-out of the Safety Harbor plant to occur by December 30, 1978. Any time delays applicable to Clearwater's construction program will be automatically applied to the Safety Harbor schedule. Please contact this office if you have any questions. ~'~P/smw Jf~. Central Files City of Safety Harbor Picot Floyd John Dennis Tampa Bay Regional Planning Council V~UlY yours, Banks B. ts~~.J District Manager Southwest District