Loading...
PERMIT C52-12912 FOR 2356 8" VCP 11 MANHOLES TO SERVICE 75 PATIO HOMES t. I I " '. tr~ \oG fV'~4~il0'~ ~,j ~l1 . / I (~) IJJ..' iY \f '?Y~' )/' ,/.~ q 'Y State of Florida DEPARTMENT OF ENVIRONMENTAL REGULATION APPROVAL OF INSTALLATION AND USE OF A SEWAGE COLLECTION/TRANSMISSION SYSTEM Pinellas County Village On The Green Phase 4 FOR AGENCY USE ONLY A. L. Shoemaker City of Clearwater 112 S. Osceola Ave. Cleatwater, Fla. 33516 Approval No.: C 5 2 -12 912 Issu~d: September 27 r 1978 Expires: January '1979 Trea~":,ent City of Clearwater FacIlity: Northeast PCP Dear Mr. Shoemaker: In reference to your recent application to this department for approval of the installation of a sewage collection/transmission system to serve the following project: Project Name: Project Location. Village On The "Green Phase 4 Intersection of Re1cher Rei ~nd T.~llrp.lw()nn nr. Project Description; 75 Patio HO'mes Popul a tion 188 peop 1 e Flow 18,800 GPD Approval of construction only has been granted subject to the following conditions: 1. The design, installation q,nd use of the facilities shall be in accordance with: your applica- tiondated ::leptember 11, 1978 .theWaterPollutionControlFederation - ' . "Manual of Practice No.9" ; appropriate provisions of Chapters 403 and 471, Florida Statutes; and the rules and regulations of the Department of Environmental Regulation. 2. The approval is only for INSTALLATION of a wastewater collection/transmission system and does not relate to any water supply aspects. The engineer of record shall supervise the construction of the engineering features of the system. At the end of construction, but prior to use, the "Certification/Approval to Use" statement (found on Page 2) must be completed and submitted tot his department and a copy forwarded to the local pro- gram (if applicable) of your county. 3. This approval is based on the understanding that adequate reserve capacity, as stated in your application and certified by the trreatment plant owner, will be available at the Ci ty of Clearwater NE sewerage treatment plant so that the wastewaters generated by this project will be collected, treated and disposed of in compliance with Chapter 403, Florida Statutes and the rules and regulations of this department. 4. Individual connections that will increase flow to the sewage treatment facility are not in- cluded in this approval. ~ DER Form PERM ",9 (Feb 77) Page'. of 2 '~. ~~ ,', J,) ~-' ~"' ' :1, -' ,~, 5 ILl I I 5. Before starting construction of this project, approvals from other federal, state, or local departments/agencies may be required. 6. Construction shall commence prior to 7. Where water and sewer mains cross with less than eighteen inches (18") vertical clearance, the sewer will be twenty feet (20' - 0") of either cast iron pipe or concrete encased vitrified clay pipe, centered on the point of crossing. 8. Wher:\ a water main paraHels a sewer main, a separation of at least ten feet (10' - 0") shouidbe maintained where practical. Sincerely. /? t:~ dt ~ r District Manager P. David Puchaty CERTIFICATION/APPROVAL TO USE This is to ,certify that, with the exception of the deviations noted in the attached letter dated , the installation of this system has been completed and tested in accordance with the application and approved plans. The system, if properly maintained and operated, shall comply with the W.P.C.F. "Manual of Practice Number 9", Chapters 471 and 473, Florida Statutes, and the rules and regulations of the Department of Environmental Regulation. The-initial three months of operation shall be under my engineering supervision. PROJECT ENGINEER CERTIFICATION DER APPROVAL TO USE Signature Date Signature of District Manager Date Florida Registration Number (Affix Seal) cc: Owner of Treatment Plant Project Engineer Edward Mazur, Jr. local Program TB RP C FPSC Records Center DE R Form PERM 11.9 (Feb 771 Page 2 of 2 '.. DEP ARTMENT<U~VJ. RONMENT AL R EGU lA TION RECEIPT FORJAPPLI~ATlON FEES AND MISCELLA1EOUS REVENUE Received from " ViJ ,I age on the Green Phase 4 " :~:;05>iW I /52S-0/}_ I ;;~ffi!?/(2c:$ ./,,!) L.S - '--' / ~ ,r.<'"o'''~;'.':' < OVh .; I . of J.t ' STATE OF FLORIDA i 1y11-~ IS;] DEPARTMENT OF ENVIRONMENTAL REGULATION 1;;;';- D APPLICATION FOR INSTALLATION OF ';:;."1 YSI'I?/i . . SEWAGE COLLECTION/TRANSMISSION SYSTEM Ct -~.:::...- .-4.=:~'"':!".-=-"=- SU\lrCC Na IlIC __Village _on the Green P-hase.. 4 _ _ County _ Pi nelJas____ __ _ StlUfI:C lOI:;ation: Street_ .see_ A ttached_ P-lans _ _ _ __. _ __ __{'ity Lat: 28 0 01 15 Long.: City of Clearwater 112 S. Osceola Avenue, Clearwater, Florlda 330lb rlp;!rw;!tpr_ 84 0 44 05 App. Name and Title:. Appl. Address: A. STATEMENTS BY APPLICANT AND ENGINEER Applicant .. /" . )f* City of Clearwater I. theXl~ll(r authorized rcpresent;atlve ( _ ___ _ _. ___.__. . _ _._ _ am fully aw;ue th;at the statements nude in this appl.il:ation fur approval of w;astew;ater collection/tr;ansmission facilitics arc truc. correct allll completc tothe he~t of my knuwlcdgc ;and helief. Further. I agrel' 10 rct:linlhc design engincer. or another profe~ion:ll cnginccr rl'gislered in Hurida. to supervisc conslrul:tion and the inilial thrce months of upcr:lliun of Ihe bdily_ I :llso :lgrec 10 m:linl:lin :lnd oper;alc Ihe f:ldlitics inl:ompli:lncc with the provisiotls of ('I\;Jptcr 403 Flu. _ rida St:ltules. and :III ;applic;able rules and rcgulations of thc Departmcnt of Environmcnt:ll Rcgulation. I undcrstand th:lt :In :lPPHlVtia. if 'rallled by the p:lrtm Itr:lnsfcr:lble and will prumplly notify the Dep-,utment upon said or legal transfer of t :I?mv~ fa .1" es_ Si!!nl'd (:::5( _ l):lle __~ If> /tf-;Y ~~~:I:~~: ~itt:;; ,," Sutk1l"iL~\~~,ratlt ~~1rpM!\M.~rtifjcate of Good Slanding must be S~b~lilled' with application. This may be obtained for a S5.00 c11:lrg~. from the Secretary of State. Bureau of Corporate Records, Tallahassee. Florida 32304. B. PROFESSIONAL .ENGINEER REGISTERED IN FLORIDA I her~by certify that the engineering features of this W"Jst~water collection/transmission system have been designed by me. III accordance with Chaptcr 403 Flori' Stat.tttes :lnd {1I:1pter 17-6. Rules of the Florida Deparlment of Environ- ment:ll Rcgu~_ ~ ~ I / . s,~,;" "" " <-<2-, · (1"- M,H "'. Add",,, 2 280 U.S. Hwy 1 9 N 5 U 1 te 1 65 _ _. _ __ Clearwater, Florida 33515 Name _~ward Mazur,_ Jr.-L1..' . __ _ __.-:-______________ (PleasClype) Cotnp:lny N:lme:_Po~t.!_ ~~~kl~y,~h~hI&--___ Telephone No.:_ J2_5~~61~ ____ Jernlgan, nc. Florid:l Rcgislraliotl Number: (Affix 5.:all 21318 I}Jte: _ _ __ ._.M~y 12, 1978 DER Form PERM 14-3 (Apr 76) Pa~ 1 or 4 I ... I DIRECTIONS: (I) All items must be completed in full in order to avoid delay in processing of this application. 121 All infurmalinn tn be Iypcd ur printed in ink. 131 Fnllr 141 cllpil"5 Ilf this applicalion and a check for twenty dollars. made oul 10 State of J-lorida , Department of Environmental Rl"J:ulalinn. will he submilh:d with this applicatilln when !lCnt tn the appropri:lle Distriet!Subdistrict office. 141 If Ihe prnjecl is hx:aled in an area under the jurisdiction of a 1Ul.";!1 pollution control and/or planning agency, furnish those agencies wilh a l'npy nf Ihis arplkalion rrim tn submiuinl! to the Department of Environmental Regulation. Enclose copies of those agencies re- marks with applicalinn. The planninj! al!t:nl-Y will certify that the proposed project is in conformanloc with the comprehensive area wide wah:r cluali.ty mana~elllent rlan as'approved by the Ikpartment. I~) Thisapplio:atinn to be an"llmranied by nne selllf engineering drawings, srecificatio", and desi~n dala as prerared by a Professional Engineer registered in Rorida, under Chapter 47 I. Flllrida Statules. The basis for design will be the: W. P. C. F. Manual of Practice. Num- ber 9. and nlher crileria as approved by this Deparlment. " I'" Allach RW' x I I' sketch nf the prupnsed project showing location of the treatmenl rlant and ernuent disposal area, its relalionship tn Ih., ,'nlill' sc:rvi.... area...mt hnw i1tic's inln the e\islin!: 'ysll'lIl. ALL INFORMATION TO HE TYPED OR PRINTED IN INK ALL COPIES OF THE APPLICATION TO BE SIGNED BY; THE APPLICANT. PROJECT ENGINEER AND THE OWNER OF THE SEW AGE TREATMENT PLANT. (I) ('ounty____ Pinell a~__ (1) (}JtcofOlpplicOltion Mav 12. 1978 (3) ApplicOlnt (name Olnd title)__City of C1 ea rwater 112 S. Osceola Avenue, Clearwater, 442-6131 (4) Mailing Addrcss Florida Zip 33516 (5) Telephone Number (6) Description of establishment to be served: a. Name_.1j}! age on the _ Green Phase 4 . "- Intersection of Belcher Road (future) and Laure1wood Drive h. LocalJon (specll,,:) . _..____..__-,_ _________.h____ _____.~.---______"___.___ c. Typc: single family homcL__. apartments_~: mobile' hom6L---':~, rri~tel__. X other (describe) Patio Homec; 75 o Flow: 250 GPO/unit d. Total number of units c. Number of ullits per connection_ _ 1 .----~ .-'''~ I '. f. Number of bedrooms pcr unit 2 ~. PopulOltion pcr uniL___ 2.5 h. NlIlIllll.'r IIr CIlII I1l'Ct illlls 75 i. TotOlI population tll bc served___ --J..BB....__-Flow: 100 GPCO ,i. Expcclcd Olverage daily !low 13.0 '(avg.) GPM 18,800 GPO ( 7) Iktails of proposed projcct: a. list lengths. sizes and material comprising proposed sewer construction mains. Gravity Forcc_. 2356 8" V.C.P., 11 Manholes Is this application llsoc:iated with or pan of a Development of RCJional Impact ( DRI ) pursuant to Chapter 3110, Florida Statutel, and Chapta 22F.2. Florida Administrative Code! .........ye' ...~....No m:R I'onn PERM 1....3 (Apr 76) Page 2 of 4 -~ I I (8) a. Pumping station dala: 1.oc.:.1I ion and/or No. Design Flow GPM Min. Max. Avg. Pump Design Charac.:tcristic.:s GPM TDH GPM TOIt No P.S. proposed under this project b-: Emergency provisions (include treatment and disposal ~f overflow): (9) Construction schedule of proposed project: Start Date June 1978 Estimated completion date September 1978 Expected date of connection to STP Seotember 1978 (10) Estimated costs (show breakdown by components) (See Attachment III II) (II) Scwagc treatmcnt plant scrving this projcct: a. Name Northeast Pollution Control Facility NE corner SR 580 and CR 31 b. Location (specific) City of Clearwater County Pine lIas c. Owner Telephone 442 6131 d. Mailing address P.O. Box 4748 33518 Zip____ ___ e.P1ant supervisor" Phil Janocha f. Certified operator x class of certification A , Not certified g. Full time operator x . Part time operator / I h. Plant influcnt loading.and treatment data: (I) Flow (MGD) Avcragc last I:! months Avcragc last 30 days _ (2) Anticipated flow upon completion of this project .5Q.._.. . .420 :4-97--- --_. - (3) AntiCIpated flow from all projects approved but not yet connec.:ted 9IL_ _ _ Plant design average 1.0 DER Form PERM 14.3 (Apr 76) Pille 3 of 4 I I :) (4) Treatment efficiency Influent Ibs./.day 5 Day BOD Ern. Percent __Ihs./day _ __ Reduclion Influent Ibs./day Total Susp. Solids Ern. Percent Ihs./daX_ _ Reduction Avg. l~ut J 2 Mos. - -- -_.-- Avg. ust 30 Days Projeci"ed upon completion -this pr~je_c!. . _______ Projected all projects appd. but not tied in ---95.4--- PLANT DESIGN AVG. .0 95.2 r ----T 95,2 II 9o~L 993 46 95.4 , i .\ - I -1723- I ---79----f---95+-4--- ---- . I 2086 -L--2e9-~-~.-o (J 2) Statement. sewage treatm~nt plant owner: * The undersigned. qwner/authorized representative* of --C.1 ty of Clearwa ter hereby certify that the above referenced plant has adequate reserve capacity to accept the wastewaters from this project and will provide the necessary treatment and disposal as required by Chapter 403. Florida Statutes and all rules and regulations of the Dcparlmef\t. Further, the undersigned verities that his treatm~nt plant is operating under a valid permit, No.PC-52-25l6 _, Dated. __.3....~6__ _____.__. issue h the Deparlment. and Ihe connecliun of thcpropused project will nul be in viola I ion uf any con - 'ons of sai p r nit. Signed Name and Tille_ - A L Shoe"':,) "" C1t.1-Ma.nager - - - Type or Priri't *Attach lelter of authorization. * This approval is granted with the clean under- standing that such approval does not mean that the City of Clearwater will automatically issue building permits to the developer identified in this application as all City sewer treatment plant capacities are apportioned and allocated by a Building Permit Review Committee, and approved by the City Manager be60re Buil~ing Permits can be issued to assure that plant capacities are not exceeded and to insure that all customers have an equal opportunity to obtain such service. DER Form PERM 14-3 (Apr 76) Page 4 or 4 . '.. I I ATTACHMENT "1" (10) Estimated Cost - Continued Sanitary Sewer (8") .......................... $14,200 Manho 1 es :.................................... 6,600 Service Lines and Connections................. 8,600 TOTAL $29,400 I ci It C"L c A If..ATE" ... ~'-If__ _'\.. .~ ,. A,n '" _ jtRC~ ~T _ ~l ... ... 'It TO eAr .'11';).< 411"RGINA ~ DDlIGLAS ,/' -Ave- ~~i I ~ i - - UH~OIt:' " ST. I 1~"" .. .. .. ... '" ':OllrT S r I CUL' ~ TO DUNCDIIt SR '.0 PFrOJECT LOCATIO:' "Ollt 1 S/I .0 VICINITY MAP I CIf 102 I r I~ ", C~::~UQ~i cS' l:t ct UNION S1 I'" -- ~.... ...1 II'~ 51 ~ ~~_ s.!!. J:a. _ ~/I '.0 I.INe /P. If. 113 TIIII/,.A c:i It ... ... ~ ~ ... ~~ N