PERMIT C52-15816 FOR VCP MAJOR INTERCEPTOR SEWAGE MAIN WITHOUT FLOW FOR PROJECT I I ( tiI,O-. '1-,' ~ ~ ~ ~; D\\~\ \ v~ M1~,~y VI, Slate of Florida DEPARTMENT OF ENVIRONMENTAL REGULATION Pinellas County Sewer East of Tract 60 APPROVAL OF INSTALLATION AND USE OF A SEWAGE COLLECTION/TRANSMISSION SYSTEM FOR AGENCY USE ONLY A.L. Shoemaker City of Clearwater 112 S. Osceola Ave. Clearwater, FL 33516 Approval No.: Issued: Expires: Treatment Facility: C52-15816 December 20, 1978 Aprl1 19/9 City of Clearwater N Dear Mr. Shoemaker: In reference to your recent application to this department for approval of the installation of a sewage collection/transmission system to serve the following project: Project Name: Project Location. Sewer East of Tract 60-Countryside ~ mile SE of Countryside Blvd. & S.R. 586 Project Description: 18" VCP Maj or Interceptor Sewage M_ain for Future No new flow from thlS project Approval of construction only has been granted subject to the following conditions: 1. The design, installation and use of the facilities shall be in accordance with: your applica- tion dated December 15, 1978 ; the Water Pollution Control Federation "Manual of Practice No.9"; appropriate provisions of Chapters 403 and 471, Florida Statutes; and the rules and regulations of the Department of Environmental Regulation. 2. The approval is only for INSTALLATION of a wastewater collection/transmission system and does not relate to any water supply aspects. The engineer of record shall supervise the construction of the engineering features of the system. At the end of construction, but prior to use, the "Certification/Approval to Use" statement (found on Page 2) must be completed and submitted tot his department and a copy forwarded to the local pro- gram (if applicable) of your county. 3. This approval is based on the understanding that adequate reserve capacity, as stated in your application and certified by the trreatment plant owner, will be available at the Ci ty of Cleatwater NE sewerage treatment plant so that the wastewaters generated by this project will be collected, treated and disposed of in compliance with Chapter 403, Florida Statutes and the rules and regulations of this department. 4. Individual connections that will increase flow to the sewage treatment facility are not in- cluded in this approval. DER FormPERM 11-9 (Feb77) Pagelof2 ) ? '...)0 (7'10 OD'::) 00 - 0'\ " I I ,J 5. Before starting construction of this project, approvals from other federal, state, or local departments/agencies may be required. 6. Construction shall commence prior to 7. Where water and sewer mains cross with less than eighteen inches (18") vertical clearance, the sewer will be twenty feet (20' - 0") of either cast iron pipe or concrete encased vitrified clay pipe, centered on the point of crossing. 8. When a water main parallels a sewer main, a separation of at least ten feet (10' - 0") should be maintained where practical. Sincerely, -~ ~~.~-"i:3___ District Manager CERTIFICATION/APPROVAL TO USE This is to certify that, with the exception of the deviations noted in the attached letter dated , the installation of this system has been completed and tested in accordance with the application and approved plans. The system, if properly maintained and operated, shall comply with the W.P.C.F. "Manual of Practice Number 9", Chapters 471 and 473, Florida Statutes, and the rules and regulations of the Department of Environmental Regulation. The initial three months of operation shall be under my engineering supervision. PROJECT ENGINEER CERTIFICATION DER APPROVAL TO USE Signature Date Signature of District Manager Date Florida Registration Number (Affix Seal) cc: Owner of Treatment Plant Project Engineer Local Program Edward Mazur, Jr. TBRPC FPSC Records Center DER Form PERM 11-9 (Feb77) Page20f2 .. ~ ~ ....~, " I I East of Tr 60/Countryside 16~D8'~EijR \ I ... ; DEe 15 1978 'SOUTHWEST DISTRICT: TAMPA . .. - . /--t~ ..-<"""".#-'" "'\..,or="' : \ .. ;/ "'\ "1)-- '\ f'-, '/'1" ~ '. -...),'...1~ \ ~ _~~~ . STATE OF FLORIDA c((.~\')..- \~ ,,\~.!..<'r EPARTMENT OF ENVIRONMENTAL REGULATION ,) ~ ~ ~_"./:(.../ APPLICATION FOR INSTALLATION OF ~~//C;J' C/' SEWAGE COLLECTIONfTRANSMISSION SYSTEM S N Sewer East of Tract 60/Countrys i dec ty ource ame oun Source Location: Street See attached plans City Pinellas " Clearwater 82 o 44 00 Lat: 28 o 01 00 Long.: Appl. Name and Title: City of Clearwater 112 S. Osceola Avenue, Clearwater, Florida 33516 Appl. Address: STATEMENTS BY APPLICANT AND ENGINEER A. Applicant . I, the owner/authorized representative of- C1 ty of Cl earwater am fully aware that the statements made in this application for approval of wastewater collection/transmission facilities are true, correct and complete to the best of my knowledge and belief. Further, I agree to retain t~~ifjR-eRglAeef-,-()f-aRetRer a professional engineer registered in Florida, to supervise construction and the initial three months of operation of the facility. I also agree to maintain and operate the facilities in compliance with the provisions of Chapter 403 Florida Statutes, and all applicable rules regulatio the Department of Environmental Regulation. I understand that an approval, if granted by the Depart en is nontra f ab n WI pty notify the Department upon said or legal transfer of the approved facilities. Signed Date December 7, 1978 A. L. Shoemaker, City Manager Name and Title .. Attach a letter of authorization. B. PROFESSIONAL ENGINEER REGISTERED IN FLORIDA I hereby certify that the engineering features of this wastewater collection/transmission system have been designed by me, in accordance with Chap r 403 Fl' t es and Ch ter 17.6, Rules of the Florida Department of Environmental Regu. lation. Signature Mailing Address: 2280 U. S. Hwy 19 N Su i te 165 Clearwater, Flor1da 33~1~ Name Edward Mazur, Jr., P.E. (Pleese Type) Company Name: Post, Buckley, Schuh & Jerni- 21318 gan, Inc. Florida Registration Number: (Affix Seel) 725-3614 Date: DER Form PE RM 14.3 (Dec. 77) Pege 1 of 4 --..-/' I I . A -,. -..... DIRECTIONS: (1) All items must be comRleted in full in order to aviod delay in processing of this application. (2) All information to be typed or printed in ink. . (3) Four (4) copies of this application and a check for twenty dollars, made out to State of Florida, Department of Environ. mental Regulation, will be submitted with this application when sent to the appropriate District/Subdistrict office. 14) If the project is located in an area under the jurisdiction of a local pollution control and or planning agency, furnish those agencies with a copy of this application prior to submitting to the Department of Environmt(ntal Regulation. Enclose copies of those agencies remarks with application. The planning age'ncy will certify that the proposed project is in conformance with the comprehensive area wide water quality management plan as approved by the Department. (5) This application to be accompanied by one set of engineering drawings, specifications and design data as prepared by a Professional Engineer registered in Florida, under Chapter 471, Florida Statutes. The basis for design will be the W.P.C.F. Manual of Practice, Number 9, and other criteria as approved by this Department. (6) Attach B~" x 11" sketch of the proposed project showing location of the treatment plant and effluent disposal area, its relationship to the entire service area, and how it ties into the existing system. ALL INFORMATION TO BE TYPED OR PRINTED IN INK ALL COPIES OF THE APPLICATION TO BE SIGNED BY: THE APPLICATION, PROJECT ENGINEER AND THE OWNER OF THE SEWAGE TREATMENT PLANT. Pine11as (1) County (2) Date of application December 4, 1978 (3) Applicant (name and title) Ci ty of Cl earwater (4) MailingAddress 112 S. Osceola Avenue, Clearwater, Florida 442-6131 Zip 33516 (5) Telephone Number (6) Description of establishment to be served: See attachment 1 a. Name b. Location (specific)Approx. 1/2 mi. southeast of intersection of Countryside Blvd. & SR 586 c. Type: single family homes * other (describe) d. Total number of units e. Number of units per connection f. Number of bedrooms per unit * g. Population per unit h. Number of connections i. Total population to be served j. Expected average daily flow (7) Details of proposed project: , apartments , mobile homes , motel * Flow: ,* GPD/unit * * * * * GPCD Flow: * * GPM GPD a. List lengths, sizes and material comprising proposed sewer construction mains. Gravity 'fOr'l:! - 1240 18" VCP. 6 manholes Is this application associated with or part of a Development of ~gional Impact (DRI) pursuant to Chapter 380, Florida Statutes, and Chapter 22F.2, Florida Administrative Code? _Yes ~o *See Attachment 1 DER Form PERM 14.3 (Dec. 77) Pege 2 of 4 ,_.<~. ,.-/ ~ ~.. _"f~' I I , -,' (8) 3. Pumping station data: ",. , . Location '_'U Design Flow GPM . Pump Design Characteristics - . and/or No. -, , Min. Max. Avg. GPM TDH GPM TDH " , No pump station , within this nroiect '. b. Emergency provisions (include tnlatment and disposal of overflow): N/A (9) Construction schedule of proposed project: Start Date December 1978 Estimated completion date December 1978 ExpecteddateofconnectiontoSTP Upon completion of future regional pump station (est. in mid 1979) (10) Estimated costs (show breakdown by components) See attachment "2" (11) Sewage treatment plant serving this project: 3. Name NORTHEAST POLLUTION CONTROL FACILITY b. Location (specific)N . E. corner S. R. 580 and C. R. 593 County pinellas c. Owner City of Clearwater Telephone 442-6131 33518 Zip d. , Mailing address P.o. Box 4748, Clearwater, F la . Phil Janocha e. Plant supervisor g. Full time operator x X class of certification A . Not certified f. Certified operator . Part time operator h. Plant influent loading and treatment data: (1) Flow (MGD) Average last 12 months Average last 30 days 5.08 5.12 (2) Anticipated flow upon completion of this project 7.0 (3) Anticipated flow from all projects approved but not yet connected 1.132 Plant design average 1.0 DE R Form PERM 14.3 (Dec. 77) Pege 3 of 4 I I .~ , ,~. ." .' (4) Treatment efficiencY 5 Day BOD Total Susp. Solids Influent Eff/. Percent Influent E ff/. Percent Ibs./day Ibs./day Reduction Ibs./day Ibs./day Reduction Avg. Last .. , 12 Mos. 712 38 -94.6 827 42 94~9 Avg. Last 923 38 95.8 902 38 :95.7 30 Days Projected upon " , .. , completion this 981 53 94.6 1139 58 94.9 project Projected all 1587 85 projects appd. 94.6 1842 94 94.9 but not tied in PLANT DESIGN A VG. 2086 209 90.0 2086 '. 209 90.0 Note: Increased flow in this interceptor main will be reflected in future permit applications as tie ins to the interceptor are applied for. (12) Statement, sewage treatment plant owner: * The undersigned, owner/authorized representative. of City of Clearwater hereby certify that the above referenced plant has adequate reserve capacity to accept the wastewaters from this project and will provide the necessary treatment and disposal as required by Chapter 403, Florida Statutes and all rules and regulations of the Department. Further, the undersigned verifies that his treatment plant is operating under a valid permit. Signed NameandTitleA. L. Shoemaker, City f-1:gr. Type or PrInt · Attach letter of authorization. * This approval is granted with the clear understanding that such 'approval does not mean that the City of Clearwater will automatically issue building permits to the developer identified in this application as all City sewer treatment plant capacities are apportioned and allocated by a Building Permit 'Review Cormnittee, and approved by the City Manager, before Building Permits can be issued, to assure that plant-capacities are not exceeded, and to insure that all customers have an equal opportunity to obtain such service. DER Form PERM 14-3 (Dec. 77) Pege 4 of 4 STATE OF FLORIDA DrARTMENT OF:~VIRQNMENTAl REGULAIION RECEIPT FOR~PPLlCATION FEES AND MISCELLANOUS REVENUE n ~ Date Dollars $ me & Address '~ venue ."..... . e Application Number By " I I Attachment "1" T . sewer wi e the - -- for the extreme nort eas area of Clearwater. T e Slze, an mlnl- mum slope for the sewer was determined by the consultant for the City of Clearwater, (Briley, Wild & Associates). Their computations showed that the following breakdown of single family, multi-family, and commercial areas will ultimately be connected to this interceptor. Breakdown 1070 Acres - Residential 30 Acres - Light Commercial Estimated equivalent population = 10,000~ Peak discharge through the 18" VCP is 2,300 GPM ~ , I Attachment "2" I (10) Estimated cost - continued Sanitary Sewer (18")......................$17,360 Ma n h ole s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 , 900 To ta 1 $21 ,260 . I I - . ,r.' , . . ---~- ;-~ __ -..,i ''-_f ~,~ ;:~~.~~~f'1;llji_:~,~~~'_~,~I~t1{;~~i=[~' ,::'~! ,.,:,. :.. '. ~ .~ .,;. : ~. > Ol )t- 'to '. ~~-. --:- c: ~ ) >= a V) ~ CURLEW RD I c: ... ~ .., a ~ PROJECT LOCATION MAIN 5T, S R ~80 "',.;--~' '~ !? () I') 7- Il'l \'s~/e'y 1 i\:'\ ~. ~V. .-l.f: -}if:- O::m~o ~ j- t:jr.0 80y -.' ~ a: U) SUNSET POINT Re. S. R. 588 DREW ST. S.R. 590 -: S,R_ ~90 S. R. 60 GlJLF TO BAY BLVD. S.R.60 VICINITY MAP