PERMIT C52-25758 -FORCE MAINS TO CITY OF CLEARWATER NE SEWAGE TREATMENT PLANT AND INTERCONNECTION OF THE TREATMENT PLANTS
;;;;~
7601 HIGHWAY 301 NORTH
TAMPA, FLORIDA 33610
J~N' E /J. .I
.., If. qt>B GRAHAM
"U '~/98, ;' GOVERNOR
- . r;:H.Wf: 0 JACOB D. VARN
, , ....Sr D ' SECRETARY
lA.a~:" j ~srJQc" DAVID PUCHATV
_.,~ ~ISTRICT MANAGER
DEPARTMENT OF ~:~~:~~o~~~TAL REGULATION ./v>>o~/JJ
I
d'~~.
"',' ",V
$/ '.' ;:-.~...~
~_:c" ;':C~~ .
i~-----'" ".~__l.__,l,
to ;.
..... '.<
", S" (,,/ ,/
'IrE Of fl09-d" '
SOUTHWEST DISTR ICT
Pinellas County - DW
NE/E Interconnect & Alligator
Creek Force Mains
Mr. Anthony L. Shoemaker
City of Clearwater
P.O. Box 4748
Clearwater, Florida 33518
Dear Mr. Shoemaker:
Enclosed is Permit Number
to construct
issued pursuant to Section
DRI C52-25758
, dated 12-28-79
403.087
, Florida Statutes.
Should you object to this permit, including any and all of the con-
ditions contained therein, you may file an appropriate petition for
administrative hearing. This petition must be filed within fourteen
(14) days of the receipt of this letter. Further, the petition must
conform to the requirements of Section 28-5.15, Florida Administrative
Code, (see reverse side of this letter). The petition must be filed
with the Office of General Counsel, Department of Environmental
Regulation, Twin Towers Office Building, 2600 Blair Stone Road,
Tallahassee, Florida 32301.
If no petition is filed within the prescribed time, you will be deemed
to have accepted this permit and waived your right to request an
administrative hearing on this matter.
Acceptance of the permit constitutes notice and agreement that the
Department will periodically review this permit for compliance,
including site inspections where applicable, and may initiate
enforcement action for violation of the conditions and requirements
thereof.
cc: Willam A Cross
TBRPC
FPSC
Records Center
SinCerelY'~
<t~ L:Wu-
I/t:~retary
Enclosure
DER Form 17-1.122(66) Paqe 1 of 2
't-
RULES OF THE ADMINISTRATIVE COMMISSION
MODEL RULES OF PROCEDURE
CHAPTER 28-5
DECISIONS DETERMINING SUBSTANTIAL INTERESTS
28-5.15 Requests for Formal and Informal Proceedings
(1) Requests for proceedings shall be made by petition to the
agency involved. Each petition shall be printed typewritten
or otherwise duplicated in legible form on white paper of
standard legal size. Unless printed, the impression shall
be on one side of the paper only and lines shall be double
spaced and indented.
----l~T - AITpetTEToi1s fllecrunaer fhes-e -rlllesshouldcon-f-airi:
(a) The name and address of each agency affected and each
agency's file or identification number, if known;
(b) The name and address of the petitioner or petitioners;
(c) All disputed issues of material fact. If there are none,
the petition must so indicate;
(d) A concise statement of the ultimate facts alleged, and the
rules, regulations and constitutional provisions which
entitle the petitioner to relief;
(e) A statement summarizing any informal action taken to
resolve the issues, and the results of that action;
(f) A demand for the relief to which the petitioner deems
himself entitled; and
(g) Such other information which the petitioner contends is
material.
DER Form 17-1.122(66) Page 2 of 2
J
I
....;..-- --- --....-....... ....
,
.. .,!
f.
I
,0. E R
J
, A N ~ J9tlO JAqOB D. VARN
-~XH ;'SECRETARY
<".. ' Wt:sr O/S'r-o DAYID PUCHATY
..,. ~~ 1.,If).J'RICT MANAGER
!
BoB GRAHAM
POVERNOR
7601 HIGHWAY 301 NORTH
TAMPA, FLORIDA 33610
I
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL REGULATION
SOUTHWEST DISTRICT
PE RM IT /i;:f IilXlf iCJM'iON
NO.
DRI C52-25758
COUNTY: Pinellas
NE/E Interconnect
PROJECT:
& Alligator Creek
This perm it is issued under the provisions of Chapter 403 . 087 , Florida Statutes, and Chapter For c e Ma ins
17- 4 . Florida Administrative Code. The above named applicant, hereinafter called Permittee, is hereby authorized to
perform the work or operate the facility shown on the approved drawing(s). plans. documents, and specifications attached hereto and
made a part hereof and specifically described as follows:
APPLICANT:
Anthony L. Shoemaker
City of Clearwater
P.O. Box 4748
Clearwater, Florida
33518
9,900 feet of 30 inch n,I.p. and 1,370 feet of 24 inch n.I.p. force
mains to the City of Clearwater NE sewage treatment plant and inter-
connecting the City of Clearwater NE and Clearwater East sewage
treatment plants.
Location: Primarily along McMullen-Booth Road, Clearwater, Florida
GENERAL CONDITIONS:
1. The terms, conditions, requirements, limitations, and restrictions set forth herein are "Permit Conditions:, and as such are bind-
ing upon the permittee and enforceable pursuant to the authority of Section 403.161( 1), Florida Statutes, Permittee is hereby placed
DER FORM 17-1.122(63) Pag.1 of3
..., f.'L ,- ") .' i
,.
I..... I
PERMIT NO.:
APPLICANT:
DRI C52-25758
Anthony L. Shoemaker
on notice that the department will review this perm it periodically and may initiate court action for any violation of the "Permit Con-
ditions" by the permittee, its agents, employees, servants or representatives.
2. This permit is valid only for the specific processes and operations indicated in the attached drawings or exhibits. Any unautho-
rized deviation from the approved drawings, exhibits, specifications, or conditions of this permit shall constitute grounds for revoca-
tion and enforcement action by the department.
3. If, for any reason, the permittee does not comply with or will be unable to comply with any condition or limitation specified in
this permit, the permittee shall immediately notify and provide the department with the following information: (a) a description of
and cause of non-compliance; and (b) the period of non-compliance, including exact dates and times; or, if not corrected, the antici-
patedtlme the non-compliance is expected to continue, and steps being taken to reduce-, eliminate, and prevent recurrence of the non-
compliance, The permittee shall be responsible for any and all damages which may result and may be subject to enforcement action by
the department for penalties, or revocation of this permit.
4. As provided in subsection 403.087(6). Florida Statutes, the issuance of this permit does not convey any vested rights or any ex-
clusive privileges. Nor does it authorize any injury to public or private property or any invasion of personal rights, nor any infringe-
ment of federal, state or local laws or regulations.
5. This permit is required to be posted in a conspicuous location at the work site or source during the entire period of construction
or operation.
6. In accepting this permit, the permittee understands and agrees that all records, notes, monitoring data and other information re-
lating to the construction or operation of this permitted source, which are submitted to the department, may be used by the depart-
ment as evidence in any enforcement case arising under the Florida Statutes or department rules, except where such use is proscribed
by Section 403.111, F .S.
7. In the case of an operation permit, permittee agrees to comply with changes in department rules and Florida Statutes after a
reasonable time for compliance, provided, however, the permittee does not waive any other rights granted by Florida Statutes or de-
partment rules.
8. This permit does not relieve the permittee from liability for harm or injury to human health or welfare, animal, plant, or aquatic
life or prolwlty and rwnalitil~s tlwrefllw caused by the construction or operation of this permitted source, nor dOl:S it allow the per-
mittee to caUSI! pollution in cllnlravl~ntion of Florida Statutes and department rules, except where specifically authoriwd by .m order
from the department granting a variance or exception from department rules or state statutes.
9. This permit is not transferable. Upon sale or legal transfer of the property or facility covered by this permit, the permittee shall
notify the department within thirty (30) days. The new owner must apply for a permit transfer within thirty (30) days. The permittee
shall be I iable for any non-compl iance of the perm itted source until the transferee applies for and receives a transfer of permit.
10. The permittee, by acceptance of this permit, specifically agrees to allow access to permitted source at reasonable times by de-
partment personnel presenting credentials for the purposes of inspection and testing to determine compliance with this permit and
department rules.
11. This permit does not indicate a waiver of or approval of any other department permit that maybe required for other aspects of
the total project.
12. This permit conveys no title to land or water, nor constitutes state recognition or acknowledgement of title, and does not consti-
tute authority for the reclamation of submerged lands unless herein provided and the necessary title or leasehold interests have been
obtained from the state. Only the Trustees of the Internal Improvement Trust Fund may express state opinion as to title.
13. This permit also constitutes:
[ ] Determination of Best Available Control Technology (BACT)
[ ] Determination of Prevention of Significant Deterioration (PSD)
[ ] Certification of Compl iance with State Water Quality Standards (Section 401, PL 92.5001
SPECIFIC CONDITIONS:
I
J
~ ."
----~....~
~- ~ -:.
I
PERMIT NO.:
APPLICANT:
DR! C52-25758
Anthony L. Shoemaker
EXJ.liration Date: February 1982
cc: Willam A. Cross
TBRPC
FPSC
Records Center
DER FORM 17-1.122(63) Page 3 of 3
I
Issued this 28111 day of ~1J1-"
79
,19_.
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL REGULATION
STA.:rE OF FLORIDA '
):>EPAR'TMENT'd'tt~ONMENTAL REGU~TION ]
RECEIPT FOR APPLICATION FEES AND MISCELLANEOUS REVENUE
n
, ~-'
I ; ,r;~'1-:
>, " ~", ,.',.'. '-"*
Dilte
V ~/
'",, I
I'
-
,.. 'j
;.../
Dollars $
me & Address
\ ~
....
~enue
I' ,;,'
,:... /
',~ J /' -t
.
/' "
..~
1_
e
/
Application Number
'~- _. '~....
.~
('I
,t ,! t# '
'I
By I
I
-----.....--
'-...
~~
_,_,~:.:J
~I,
~:~-.........r
....
I
;;f:'.~;''1~~
~ ~ ............v "
f /-.~.~J]';c~~~
~~~~
'..,,fl:4rEOF FlO!~~'
STATe OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL REGULATION
APPLICATION FOR INSTALLATION OF
SEWAGE COLLECTION/TRANSMISSION SYSTEM
.<IIl,:.
,
.
)1
D.E,~
'tJ 'C ')
..
,~'
NO 11 :1',"
~l}l~Vr.-('-: '
l..,,'1 l t, 'I
.,. '.
.J;t~ ~,;.'..,
"Y'-''r'..'"
'.,...
lC.,.
Source Name Northeast/East Interconnect and Alligator Creek Forctounty Pinellas
h 9 Main
Source Location: Street Bays ore Dr,Drew St,S.R,5 3,C.R.48, City Clearwater
Latitude: ~0-2L'~" C.R. 77 Longitude~o~'~"
Appl. Name and Title: City of Clearwater
Appl.Address: City Hall. P.O. Box 4748. Clearwater. Florida 33518
STATEMENTS BY APPLICANT AND ENGINEER
A. Applicant
I, the owner/authorized representative* of The City of Clearwater
am fully aware that the statements made in this application for approval of wastewater collection/transmission facilities are true,
correct and complete to the best of my knowledge and belief. Further, I agree to retain the design engineer, or another profes-
sional engineer registered in Florida, to provide observation of construction and, if applicable, the initial three months of opera-
tion of the facili I also agree to maintain and operate the facilities in compliance with the provisions of Chapter 403, Florida
Statutes, and a Ii able rules and regulati the Department of Environmental Regulation. I understand that an approval, if
granted by th de artme t, is nontransf n' promptly notify the department upon sale or legal transfer of the ap-
proved facili es.
Date
Iftf!
Signed
* Attach a letter of authorization.
B. PROFESSIONAL ENGINEER REGISTERED IN FLORIDA (where required by Chapter 471, Florida Statutes)
I hereby certify that the engineering features of this wastewater collection/transmission system have been designed by me in ac-
cordance with Chapter 403, Florida Statutes, and all applicable rules and regulations of the Department of Environmental
Regulation.
Signed $(d~ /~
Mailing Address Briley. Wild & Associates
Name (please type) William A. Cross
Company Name, Briley, Wild & Associates
P.O. Box 607
Ormond Beach, Florida
32074
_FlorldlFlegtstrltlon Number
85%0
(904)672-5660
Telephone No.
October 29, 1979
Date
---- ''''''--
'-::::
-(Affix Seal)
"-' --
DER FORM 17,1,12<l(3) Page 1 of4
DIRECTIONS: - ~ --
-- -
(1) All items lJlu.stbecompleted in full in order to avoid delay in processing of this application.
-
(2) All jnforma.ti.on is to be typed or printed in ink.
(3) Four (4) copies of this application and a check for twenty dollars ($20). made out to the State of Florida, Department of En.
vironmental Regulation, will be submitted with this application when sent to the appropriate District/Subdistrict office.
(4)
If, the project is located in an area under th, e jUriSdictio, n of a local pollution control and/or planning agency, furnish those agenC--
cies with a copy of this application prior to submitting to the Department of Environmental Regulation. Enclose copies of those \
agencies' remarks with application. The planning agency will certify that the proposed project is in conformance with the com. \
prehensive area wide water quality management plan as approved by the Department.\
(5) This application is to be accompanied by one set of engineering drawings, specifications and design data as prepared by a Pro.
fessional Engineer registered in Florida, where required by Chapter 471, Florida Statutes. The basis for design will be the
W.P.C.F. Manual of Practice, Number 9, and other criteria as approved by this Department.
\
\
(6) Attach 8%" by 11" sketch of theproposedprpjectshovllinllJocation_of the treatment plant and effluent disposal area, its rela,
tionship to the entire service area, and how it ties into the existing system.
NOTE: FOR ASTERICK NOTATIONS SEE LAST PAGE
ALL INFORMATION TO BE TYPED OR PRINTED IN INK. ALL COPIES OF THE APPLICATION TO BE SIGNED BY: THE
APPLICANT, PROJECT ENGINEER AND THE OWNER OF THE SEWAGE TREATMENT PLANT.
(1) County Pinellas
(2) Date of application October 29, 1979
(3) Applicant (name and title) City of Clearwater, Clearwater. Florida
(4) Mailing Address Ci ty Hall, Clearwater, Florida
(5) Telephone Number (813) 462-6500
Zip: 33518
(6) Description of establishment to be served:
Name Portion of City of Clearwater Service Area
a.
b. Location (specific) See Attached Map
c. Type: single family homes K)q, apartments lXX, motel XXI, mobile homes [xX, other (describe) <;;€lIH~ral COllllllercial
d. Total number of units Varies Flow: Varies GPD/unit
e. Number of units per connection
Varies
f. Number of bedrooms per unit
Varies
i.
Varies
Al11gator creeK:FOrce Ma1n - Approx1mately 20,300
Number of connections Northeast/East Interconnect - N/ A *
Alligator Crk. Ft M.,,~5*000 Alligator Crk, F.M. - Approx. 225
Total population to be served NE; t: Interconnec FloW A NE/E Interconnect - N/ A * GPD/unit
Al11gator Crk, F.M. - 3820 Alligator Crk. F.~1. 5.5 million
ExpectedaveragedailyflowNE7E Interconnect- N/A** GPMNE/E Interconnect - N/A** GPD
g.
h.
Population per unit
j.
(7) Details of proposed project:
a. List lengths, sizes and material comprising proposed sewer construction mains. Gravity
None
Force 30 inch D. I . P. - 9,900 ft.
24 inch D,I.P. - 1,370 ft.
Is this application associated with or part of a Development of Regional Impact (DR I) pursuant to Chapter 380, Florida Statutes, and
Chapter 22F.2, Florida Administrative Code? !XK Yes [] No
.
',. ...'"'"_....
~,R FORM 17 1.122(3) PaQo 2014.
...
I
~.~'r ~
I
--
.~
,.
j--" "
I
I
(8) a. Pumping station data: N/ A
Design Flow GPM Pump Design Characteristics
Location and/or No.
Min. Max. Avg. GPM TDH GPM TDH
b. Emergency provisions (include treatment and disposal of overflow):
N/A
(9) Construction schedule of proposed project:
Start Date: March, 1980
Estimated Completion Date: September, 1981
Expected Date of Connection to STP: September, 1981
(10) Estimated Costs (show breakdown by components):
SEE ATTACHED
(11) Sewage Treatment Plant serving this project:
a. Name:
Northeast Plant
b. Location (specific): N. of S. R. 580 , E. of McMullen Booth Road County: Pinellas
c. Owner: City of Clearwater Telephone: (813) 462-6500
d. Mailing address: City Hall, Clearwater, Florida Zip: --13518
e. Plant supervisor:
F. J. Janocha
f. Certified operator: Ral ph Johns
Class of Certification: Class A
Not certified:
g.
Full- time operator: (1) Class A, Cerfificate #512
Part-time operator: (1) Class A, Cert. #509; (2) Class A, Cert. #3785; (3) Class C, Cert.
#4458.
h. Plant influent loading and treatment data: * * *
(1 )
Average last 30 days:
(2)
(3)
AII1Rator creek ~orce Maln - ~,5 MGU
Nortfieast/East Interconnect - N/A**
Anticipated flow upon completion of this project:
Anticipated flow from all projects approved but not yet connected:
Plant design average: 8 MGD
OER FORM 17-1.122(3) Page 3 of 4
(4) Treatment efficiency:
5 Day BOD Total Susp. Solids
Influent Effluent Percent Influent Effluent Percent
Ibs/day Ibs/day Reduction Ibs/day Ibs/day Reduction
Avg. Last 1050.8 53.3 95% 1067.2 84.3 92%
12 Mos.
Avg. Last 1237.3 23.5 98% 1229.5 96%
30 Days 54.8
Projected upon 9200.6 920.1 90% 9341. 1 934.1 90~6
completion this project
Projected all projects
appd. but not tied in
--
PLANT DESIGN AVG. 13,340 1,330. 90 13 , 340 1,330 90
(12) Statement, sewage treatment plant owner:
The undersigned, owner/authorized representative* of The City of Clearwater
hereby certifies that the above referenced plant has adequate reserve capacity to accept the wastewaters from this project and
will provide the necessary treatment and disposal as required by Chapter 403, Florida Statutes and all rules and regulations of
the department, Further, the undersigned verifies that his treatment plant is operating under a valid permit, No. DC5Z -17616,
dated 3/7/79 ", issued by the department, the connection of the project will not be in
violation of any conditions of said permit.
Signed:
L. Shoemaker, City Manager
(Please Type)
Name and Title:
* Attach letter of authorization
NOTES:
*Northeast/East Interconnect will either a). Carry effluent from Northeast Plant to East
Plant for disposal or b). Pump Sewage from East to Northeast Plant for treatment.
**Northeast/East Interconnect will vary depending on actual direction of flow. 5.3 MGD raw
sewage for flow from East to Northeast or 18.6MGD effluent from Northeast to East.
***Data given is for recently phased out 1.0 MGD Northeast Interim Treatment Plant. Northeast
Plant has just been increased to 8 MGD and no monthly operating reports are available at
this time.
'. ~
DER FORM 17-1.122(3) Page 4 of 4
..'
I
I
I':'''~
;,~-:-.11
-~
'-"rir- w
''f' .
~
~ I
I
I
I
I
.
I
I .
~------~
()
,-------.,
&._------'
===::J
1"- ==:::1 rl"-"-+
c::::=:5 ~--; I C R 102
~~==4
l --II d=::J
".I~'"
C2'o -#----
I'.;e~
: ~-:~u --
, 14.. hf. III
. I~~D
: =-::'-=:1 c=:::J D
, e-!"--"1' C::::=J 0
: ~i-'C=S C-::J D:
I , ", ..~ ~ .IoUOul .~~o 4-
. -==::1 c=:J'
,:~ ":!. C;==1.
r=-::'J C=:J ~
t=!::..-'j' C==:J
'-1 .~"'~=]:~d
I : r;..--d I .
I ~ l..~ ,C::=::J
,.J ~f'
.,. .. ~ f c::;::J c:::=J
~-;;'-=;.(Q c:::=J
[===:J c::::=J c:::::J
-n ~
j ....UA 1 I
tj _____r-- _.Il :
~ ' , ~l j
Ld P [:_-_-~ {.lL--___________]~.
-----1 [1r~:A---- - - - - -TrJ--'.i--mu....
~'i=:JlC=:::> 09 , rrn~. ,I
P'11 __,,".. A ( ! I~ I~. o,~
r------------
~ I II
I
I
I
I
______J
.
.
! I
I
~'''''''''I NORTHEAST
:~~~T~~ ~~~~~~~~ETR
I ~ FfCILlTY
~
:::.:::
w
w
o::Z
u-
<!
0::2:
Ow
!-u
<!o::
~O
..JlL.
..J
<(
')
I-
Zw
Wz
:)-
.J-l
lL.z
lL.
w~
I-~
(/)-
<!~
W(/)
IZ
1-<(
0::0::
01-
Z
;\~~:[
~~~~'~~I
~ ~.~OJrlOlll
~~.
.A :.. la.l._
<&:7 :o~ ~c;;;::
~J l=.r-
SHEET I of 2'
.. '.~
:J CJ
...
~
------,
,
,
,
,
I
.
" I-----......
.... - - - - - - --
r- -,
I I
!
,.;
~
J
.-.-
EAST P.C.F.
..... ,",
",-' "
. . ,
. . - - - - - -. - ., " "
I rK"'.J.~""~"h' ) 'w'
,)) , ,-
, , , r
':~~~~i f
I I'
I
- I
~. ,----
SHEET 2 of 2
I
E-2
I
,.~... ..
.'
I
I
NORTHEAST EFFLUENT TRANSMISSION LINE
AND
ALLIGATOR CREEK FORCE MAIN
CLEARWATER, FLORIDA
Item Unit
No. Description Quantity Unit Price Amount
6. Pavement Replacement
a. Construct Stabilized
Subgrade 6-inches
thick 7,300 Sq. Yd. $ 1.17 $8541. 00
b. Construct limerock
base course 6-inches
thick with prime coat 6,700 Sq. Yd. 3.39 22713.00
c. Construct all-
weather surface
course prior to
complete surfacing 6,700 Sq. Yd. 2.12 14204.00
d. Construct Asphaltic
Concrete Surface
Course Type S-l
l~-inches thick 13,360 sq. Yd. 2.44 32598.00
e. Asphalt Pavement
Patch 350 Sq. Yd. 11. 82 4137.00
f. Concrete Sidewalk 200 Sq. Yd. 12.35 2470.00---
g. Concrete Pavement 90 Sq. Yd. 13.52 1217.00
h. Concrete Curb 100 Lin. Ft. 9.75 975.00
---.-,.
Total - Part I $894,151. 00
PART II
EPA ELIGIBLE
7. Furnish & Install
Ductile Iron Pipe
Force Main
a. 30-inch by open cut 30,725 Lin. Ft. 45.58 1,400,446.00
b. 24-inch 5,240 Lin. Ft. 37.10 194,404.-1)0
c. 16-inch 50 Lin. Ft. 26.50 1,325.00
d. 3D-inch by Jacking 120 Lin. Ft. 212.00 25,440.00
8. Furnish & Install
Cast Iron Fittings 18 Ton 3366.00 60588.00
E-3
., . . . .
, ' I
I
NORTHEAST EFFLUENT TRANSMISSION LINE
AND
ALLIGATOR CREEK FORCE MAIN
CLEAffi'lATER, FLORIDA
Item Unit
No. Des~~iption Quantity Unit Price Amount
9. Furnish & Install
Valves
a. 16-inch Plug
Valve 1 Each $ 2968.00 $ 2968.00
10. Construct Special
Crossings
a. Highway Crossing
No. II-I 1 Lump Sum ~920 ..QL..
b. Highway Crossing
No. II-2 1 Lump Sum 33,920.00
c. Water Main
Crossing No. II-A 1 Lump Sum 14,840.00
d. Water Main
Crossing No. II-B 1 Lump Sum 16,960,00
e. Water Main
Crossing No. II-C 1 Lump Sum 7,844.00
f. Water Main
Crossing No. II-D 1 Lump Sum 14,840.00
g. Water Main
Crossing No. II-E 1 Lump Sum 14,840.00
lI. Subsoil Excavation 625 Cu. Yd. 5.30 3,313.00
12. Special Refill
Material 750 Cu. Yd. 10.60 7,950.00
13. Lumber & Sheathing
l,e ft in Place 30 MBF 530 :00 15,900.00
14. Connections to
Existing Mains
a. 30-inch 1 Each 2,120.00 2,120.00
b. 24-inch 2 Each 1,590.00 3,180.00
15. Furnish & Install
Air Release Valves
with Manholes
a. 30-inch diameter main 12 Each 1,696.00 20,352.00
b. 24-inch diameter main 2 Each 1,643.00 3,286,00
E-4
'. ' . .
c' ,
. ' I
I
NORTHEAST EFFLUENT TRANSMISSION LINE
AND
ALLIGATOR CREEK FORCE MAIN
CLEARWATER, FLORIDA
Item Unit
No. Description Quantity Unit Price Amount
16. Pavement ~eplacement
a. Construct Stabilized
Subgrade 6-inches
thick 25,100 Sq,. Yd. $1.17 $29,367.00
b. Constructlinierock
base course 6-inches
thick with prime
coat 23,200 Sq. Yd. 3.39 78,648.00
c. Construct all-
weather surface
course prior t.o
complete surfacing 23,200 Sq. Yd. 2.12. 49,184.00
d. Construct Asphaltic
Concrete Surface
Course Type S-I
1~-inches thick 43,300 Sq. Yd. 2.44 105,652.00
e. Asphalt Pavement
Patch 400 Sq. Yd. 11. 82 4.728. OQ_"
f. Concrete Sidewalk 100 Sq. Yd. 12.35 1,235.00
g. Concrete Pavement 40 Sq. Yd. 13,78 551. 00
h. Concrete Curb 40 Sq. Yd. 10.60 424.00
Subtotal - Part II
EPA Eligible
$ 2 .148.225.00
PART II
CITY FINANCED
17. Furnish & Install
Ductile Iron Pipe
Water Main
a. 12-inch
12 ,710
Lin. Ft. 21.20
269,452.00
18. Furnish & Install
Cast Iron Fittings
5
Ton 3,366.00
16,830.00
19. Furnish & Install
Gate Valves Complete
With Boxes
a. 12-inch
10,176.00
12
Each 848.00
E-5
.
... . ..,~ .
I
I
NORTHEAST EFFLUENT TRANSMISSION LINE
AND
ALLIGATOR CREEK FORCE MAIN
CLEARWATER, FLORIDA
Item Unit
No. Descriptior. Quantity Unit Price Amount
20. Furnish & Install
Fire Hydrants 25 Each $1. 007 . 00 $25.175.00
2l. Cut-ins & Connections
- to existing mains
a, 12-inch x l2-inch
cut-in 1 Each 2,279.00 2,279.00
b. 20-inch connection 1 Each 1,378.00 1,378.00
22. Subsoil Excavation 750 Cu. Yd. 5.30 3,975.00
23. Special Refill
Material 1,000 Cu. Yd. 10.60 10,600.00
24. Pavement Replacement
a. Asphalt Pavement
Patch 200 Sq. Yd. 11. 82 2,364.00
b. Concrete Sidewalk 100 Sq. Yd. 12.35 1,235.00
c. Concrete Pavement 30 Sq. Yd. 13.78 413,00
d. Concrete Curb 40 Lin. Ft. 10.60 424.00
e. Asphaltic Concrete
Surface Course
Type S-l 300 Sq. Yd. 2.44 732.00
Subtotal - Part II -
City Financed $ 345 .033.00
Total Part II $2',493,258.00
E-6