Loading...
CLEARWATER HIGH AND DRY MARINA MULTI-SITE FEASIBILITY STUDY I I I I I I I I I I I I I I I I I I KCkarwater Z;~ .~ I Clearwater High and Dry Marina Multi-Site Feasibility Study It] WADETRIM I I I I I I I I I I I I I I I I I I I Clearwater High and Dry Marina Multi-Site Feasibility Study Prepared For: The City of Clearwater, Florida January 2007 Prepared By: It] WADETRIM 8745 Henderson Road, Renaissance 5, Suite 220 Tampa, Florida 33634 813.882.8366 Study made possible in part with grant funding from the Florida Fish and Wildlife Conservation Commission Florida Boating Improvement Program I I I I I I I I I I I I I I I I I I I Executive Summary It] WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study The City of Clearwater proposes to develop a high and dry boat marina to meet the growing demand for boat storage within the City and Pinellas County. The goal is to add approximately 250 to 300 high and dry storage spaces including associated trailer and visitor parking, limited marine service, utilities and landscaping with convenient access to the Intracoastal Waterway. The facility is envisioned to serve the storage needs of vessels thirty five (35) feet or less. Over the past five years the City has lost approximately 500 high and dry boat storage slips due to the conversion of new residential developments on Clearwater Beach and the mainland. Three sites were evaluated as potential locations for a new high and dry boat storage facility: · Jack Russell Stadium · Stevensons Creek . Seminole Boat Ramp The study was funded by a grant from the Florida Fish and Wildlife Conservation Commission, Florida Boating Improvement Program. Wade Trim, one of the City's Engineers of Record, was retained in February 2006 to complete the multi-site feasibility study. This is the first phase of what will likely be a three phased project. The study identifies and analyzes a host of factors that contribute to the process of selecting a preferred site. These factors include such things as land ownership patterns, programmed uses for the sites, current and future land use of the property and zoning designation, environmental concerns such as noise and impact on wetlands and seagrasses, existing character of the surrounding area including recently approved projects, location and adequacy of infrastructure, traffic management, neighborhood compatibility and "project perception" by nearby residents. The constraints and opportunities of each site are presented in a Site Evaluation Matrix (See Table 3.1) The Seminole Boat Ramp site is recommended as the preferred site for several reasons: . Has the best waterfront access of the three sites . There are existing facilities already serving the site that could be used for the proposed high and dry (e.g. docks, boat ramps, trailer parking) · City-owned property adjacent to the boat launch facilitating site expansion . Water related uses are promoted in the Downtown Development Plan and this site is identified for improvement as an end destination . Anticipated environmental impacts associated with adding docks are manageable · Traffic patterns in the area are well established c1w2066.01 m\gis-data\reports\feasibility study jan 2007 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study . Adjacent developments include condominiums linked to marinas making the proposed project compatible with the existing redevelopment pattern. . If relocated, the Francis Wilson Theatre could provide for additional surface parking supporting the facility The study also identifies general design and planning standards related to the development of high and dry boat storage facilities including structure types (clear span, rack supported and vertical automated systems). Six alternative concept plans for the high and dry facility were developed for the Seminole Boat Ramp site graphically illustrating a single building or two building footprint. The preferred site plan contains a single building footprint with approximate dimensions of 250 feet by 260 feet. Estimated building height is 50 feet. This could change based on the additional study ofthe preferred method of retrieving and storing the boats (i.e. conventional forklift or automated retrieval and storage). It is recommended that the building employ a "green" roof concept making the building environmentally friendly and enhancing building aesthetics and views from the bluff. The entry drive from Osceola Avenue has been realigned in the concept plans along with improved pedestrian circulation, extensive screen plantings, boat wash area, improved boat launch area including a new dock along the western seawall for vessel staging and improved park area (at the west end of the existing parking lot). The Phase I Concept assumes the Francis Wilson Theatre remains in place. Phase II assumes the future off-site relocation of the theatre, thereby providing additional surface parking and landscaping at the site. Order of magnitude cost estimates in 2006 dollars range from $15,000 to $22,000 per vessel storage space depending upon the type of facility selected. Employing the green roof concept could potentially add approximately $975,000 to the cost of the structure assuming the current footprint. An enhanced building fa<;ade will likewise increase the estimated cost, but is highly recommended for this facility given its proximity to existing and proposed residential development along the bluff. Generalized cost estimates were provided by two recognized vendors: Roof and Rack (conventional) and Vertical Yachts (vertical automated system). More definitive construction costs should be developed in a subsequent phase of the project recognizing this first phase focuses on identifying a preferred site for the proposed high and dry facility. The next study phase should include at a minimum: . A detailed market study documenting existing and future demand . Defining the preferred system of storing and retrieving boats and the detailed costs associated with those facilities · Preparing preliminary engineering studies and preliminary site plan · Developing more detailed construction cost estimate for the preferred system and site improvements · Developing a detailed cost revenue analysis including funding options. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 II I I I Table of Contents It] WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I . S . Executive ummary................. ......... ................. ...................... ..... .......... ............ .... I I I I 1.0 Project Description and Study Methodology.................................................. 1 Map 1.1 Site Locations ....................................................................................2 2.0 Analysis of Site Alternatives ........................................................................... 4 I 2.1 Jack Russell Stadium (Site 1) ........................................................................ 4 Table 2.1 Jack Russell Site: Adjacent Existing Land Use .......................................4 Map 2.1 Jack Russell Stad i u m .... ..................... ......... ..... .......... ........... ........ ......5 Map 2.2 Jack Russell Stadium: Existing Land Uses Adjacent to Site ................ 6 Table 2.2 Jack Russell Site: Adjacent Future Land Use .....................................8 Map 2.3 Jack Russell Stadium: Future Land Use Adjacent to Site ...................9 Map 2.4 Jack Russell Stadium: Zoning Districts Adjacent to Site ..................10 Map 2.5 Jack Russell Stadium: Existing Laneage along Launch Route .......... 11 Table 2.3 Jack Russell Site: Launch Route Existing Land Use.......................... 12 Table 2.4 Jack Russell Site: Launch Route Future Land Use ............................12 Map 2.6 Jack Russell Stadium: Future Land Uses Adjacent to Launch route.. 13 Map 2.7 Jack Russell: Stadium Potable Water ............................................... 15 Map 2.8 Jack Russell Stadium: Reclaimed Water ..........................................16 Map 2.9 Jack Russell Stadium: Storm water .................................................... 17 Map 2.1 0 Jack Russell Stadium: Wastewater ................................................... 18 2.2 Stevensons Creek Shuffle Board and Lawn Bowls Complex (Site 2) ......... 19 Table 2.5 Stevensons Creek Site: Adjacent Existing Land Use ........................ 20 Map 2.11 Stevensons Creek: Existing Land Uses Adjacent (200') to Site ......... 21 Table 2.6 Stevensons Creek Site: Adjacent Future Land Use ...........................23 Map 2.12 Stevensons Creek: Future Land Uses Adjacent (200') to Site ........... 24 Map 2.13 Stevensons Creek: Zoning Districts Adjacent to Site .......................25 Map 2.14 Stevensons Creek: Site Initial Ecological Assessment ......................26 Map 2.1 5 Stevensons Creek: Adjacent Approved Projects ............................... 28 Map 2.16 Stevensons Creek: Existing Laneage along Launch Route ................ 29 Table 2.7 Stevensons Creek Site: Launch Route Existing Land Use .................30 Table 2.8 Stevensons Creek Site: Launch Route Future Land Use ...................30 Map 2.17 Stevensons Creek: Existing Land Uses Adjacent to Launch Route ...31 Map 2.18 Stevensons Creek: Future Land Uses Adjacent to Launch Route ...... 32 Map 2.19 Stevensons Creek: Potable Water ..................................................... 34 Map 2.20 Stevensons Creek: Stormwater ......................................................... 35 Map 2.21 Stevensons Creek: Wastewater ........................................................ 36 2.3 Seminole Launch Ramp (Site 3) .................................................................. 37 Table 2.9 Seminole Boat Launch Ramp: Adjacent Existing Land Uses ............37 Map 2.22 Seminole Boat Ramp: Existing Land Uses Adjacent (200') to Site ...38 Table 2.1 0 Seminole Boat Launch Ramp: Adjacent Future Land Use ................40 Map 2.23 Seminole Boat ramp Site Initial Ecological Assessment...................41 Map 2.24 Seminole Boat Ramp: Adjacent Approved Projects .......................... 43 Map 2.25 Seminole Boat Ramp: Potable Water ...............................................45 I I I I I I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 I I I I I I I I I I I I I I I I I I I It] WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.26 Semi nole Boat Ramp: Stormwater .................................................... 46 Map 2.27 Seminole Boat Ramp: Wastewater ...................................................47 Map 2.28 Seminole Boat Ramp: Downtown Redevelopment Plan Character Districts ..... ......................... .............................................48 2.4 DRI Thresholds for High and Dry Marinas ................................................ 49 3.0 Conclusion on Site Feasibility ....................................................................... 50 3.1 Constraints and Opportunities ................................................................... 50 Table 3.1 Draft 11- Site Evaluation Matrix ........................................................52 4.0 Design and Planning Standards for High and Dry Marina Facilities. .............. 57 4.1 Defining the Building Size: Width, Length and Height. ............................. 57 Table 4.1 Average Boat Sizes .......................................................................... 57 Table 4.2 Typical Aisle Widths..... ........... .......................... .............. ........ ........ 57 Table 4.3 Typical Heights for Rack Levels ....................................................... 58 4.2 Structure Types/ Building Design ............................................................... 58 4.3 Building Ma terials ................ .......... ....... ....... .............. ..... ....... ............ ........ 62 4.4 Site Planning.. ............ ............ .... ..... ....... ................. .... ........ .... ............... ..... 62 5.0 Proposed Faci I ity ...... ............. ...................... .................. .......... ...... ......... ..... 64 5.1 General Development Guidelines ............................................................. 64 5.2 Conceptual Diagrams...... ........ ......... .......... ....... ....... ....... ............ ..... .......... 64 Table 5.1 Existing and Proposed Parking and Boat Storage Capacity.............. 65 Option 1 ..... ..................... .................................. ..............................66 Option 2 .......................................................................................... 67 Option 3 ..... ..................................................................................... 68 Option 4 .......................................................................................... 69 Option 5 ................................................ .......................................... 70 Option 6 .......................................................................................... 71 5.3 Conceptual Site Plan ....... ....... ....... .............. ...................... ..... ... ......... ........ 72 Conceptual Site Plan Phase 1 ..............................................................................73 Conceptual Site Plan Phase 2 ..............................................................................74 5.4 Cost Estima tes .... ..... ....... ............... ........................ .............. ............... ........ 76 Table 5.2 Estimated Cost for Marina Equipment .............................................. 77 6.0 Next Steps. ... ...... .......... ........ .......... .......................... ... ............... ..... ........ ..... 78 APPENDICES APPENDIX 1: Delta Seven - Initial Environmental Assessment APPENDIX 2: Bathymetric Survey Stevenson Creek Site c1w2066.01 m\gis-data\reports\feasibility study jan 2007 I I I I I I I I I I I I I I I I I I I Clearwater High and Dry Marina Multi-Site Feasibility Study It] WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 1.0 Project Description and Study Methodology The City of Clearwater proposes to develop a high and dry boat marina to meet the growing demand for boat storage within the City and Pinellas County. The goal is to add approximately 250 to 300 high and dry storage spaces accessible to the Intracoastal Waterway north of downtown Clearwater including associated trailer parking, limited marine service, utilities and landscaping. The facility is envisioned to serve the storage needs of vessels thirty five (35) feet or less. Over the past five years the City of Clearwater has lost approximately 500 high and dry boat storage slips due to conversion to new residential developments on Clearwater Beach and the mainland. Compounding this loss of boat storage facilities in the City is the growing demand for high and dry storage facilities statewide which is well documented. Three sites were identified as potential locations for a new high and dry marina. (See Map 1.1) They are: . Jack Russell Stadium Site (Site 1) generally located south of Palmetto Street, north of Seminole Street between Dr. Martin Luther King Jr. Avenue and Jefferson Avenue in the Greenwood Neighborhood . Stevensons Creek Site (Site 2) generally located at the intersection of North Fort Harrison Avenue and Calumet Street . Seminole Boat Ramp Site (Site 3) located west of the intersection of Seminole Avenue and Osceola Avenue In February 2006 the City received a grant from the Florida Fish and Wildlife Conservation Commission, Florida Boating Improvement Program to fund this site feasibility study. The City retained Wade Trim, Inc., one of its Engineers of Record, to conduct the site feasibility study. The grant provides an opportunity for the City to complete a cursory site feasibility analysis for the three sites in order to identify a preferred site for the high and dry marina as the first phase in the planning, design, permitting and construction and operation of the needed facility. As specified in the scope of work approved by the City Council and State of Florida, the study includes the following items with respect to the three sites: · Land ownership patterns · The City's programmed uses for the selected sites · Bathymetric survey for the Stevensons Creek site · Cursory mangrove and seagrass surveys for the Stevensons Creek site · Current land use and zoning of each site and neighboring properties c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 1 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 1.1 Site locations I Q. cu ~ CJ) If) rn c: ell 0 4: >- -0 ro ::> () ii5 0 $ -.J i:i) Q) I (/) '" jI ~ M ci 'i 0 w 1<l ::;s '-<roo N .,; ci ~ ~ <{ -'" E-< U ~ mOO i s ci Oc; -~ o c on ~, _ 0 0 UU ci ~; ... ;sti 0 sif I ~ ... CQ)~ .... .... .- "Om s::: I cu~ T"" I ~ .- "0 .c ._ ::::J U).... J:::::Jcum C)~ Q) .- LL. ::I: T"" I I I I I I I I I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 2 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study . Identification of recently approved projects in the area of each site and the perceived impact of those projects on the proposed high and dry marina . Identification of applicable Land Development Code provisions governing the location and construction of the proposed high and dry marina . The location and adequacy of existing infrastructure to serve the marina and associated uses . Review of Chapter 380.06 F.5. regarding DRI thresholds for high and dry marinas and other applicable local, state and federal permitting requirements . Traffic management issues including ingress, egress and cursory assessment of impact on surrounding roadway system. . Identification of potential neighborhood compatibility and/or project "perception issues" . Order of magnitude pre-design construction cost estimates including site demolition and clearing, utility upgrades, if required, to serve the sites, site development costs, seawall construction and bridge replacement costs that cou Id be uniquely associated with the Steven sons Creek site as well as order of magnitude cost estimates for design and permitting processes. . Estimated schedule for design, permitting and construction . Estimated annual operations and maintenance costs and revenue generating estimates A detailed market study and cost revenue analysis are not included in this phase of the project. Once a preferred site has been selected, the next study phase would likely include a detailed market study documenting existing and future demand, a detailed cost revenue analysis including funding options, the preferred system of storing and retrieving boats from the high and dry facility and estimated construction costs associated with those facilities, preliminary engineering studies and preliminary site plan for the preferred site. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 3 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 2.0 Analysis of Site Alternatives 2.1 Jack Russell Stadium (Site 1) 2.1.1 land Use, Zoning and Code Provisions The Jack Russell Stadium Site is located within City of Clearwater Neighborhood District II, specifically the North Greenwood Neighborhood. The site is bounded by the following thoroughfares: Palmetto Street (North), Martin Luther King Jr. Avenue (West) and Seminole Street (South). (See Map 2.1) The 18.8 acre site is composed of four parcels owned by the City of Clearwater. It is considered one of the largest pieces of land with potential for redevelopment in Pinellas County. The current uses of these parcels are recreation/open space and commercial, because of activities developed on the Jack Russell Stadium property. Due to its structural condition, the Stadium is proposed to be demolished in early 2007. The future land use designation for the site is Recreation/Open Space and it is zoned as Recreation/Open Space (R/OS). The proposed high and dry facility will not require changes to the existing land use and zoning designations at this site, since it is considered a recreational use. The immediate area of influence of the site is about 55.12 acres with a variety of land use types. The majority is public/semipublic and residential (single family and multifamily). Table 2.1 and Map 2.2 provide a description of the existing uses surrounding the site. Table 2.1 Jack Russell Site: Adjacent Existing Land Use Existing Land Use Number of Percentage Area Percentage Parcels (Parcels) (Acres) (Area) Commercial 4 4% 1.24 2% Duplex-Triplex 5 5% 0.85 2% Industrial 7 8% 3.17 6% Multi-Family 1 1% 8.24 15% Public/Semi-Public 7 8% 23.66 43% Recreation/Open Space 1 1% 4.55 8% Single-Family 50 54% 10.65 19% Vacant 18 19% 2.76 5% Total 93 100% 55.12 100% Source: Pinellas County GIS, 2005 c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 4 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.1 Jack Russell Stadium I ~ Q; Q) L. LL ~. 0 C Q) c:- o '<t .... .... ~ rn ~ ~ Q) E '0 "C en (J) c w ::E .- "C N "<'""" (J) ::J Z-<r. '" ~ 0 i p;: c: I .c ~.- m .- ::s c. Q) 0:::"0 << ~ CO .- ...... "'" .... co 0 ~~ en .... (j) $ 0 CO .::s::. ...... N ~ . en en ~a ~ .c: ::s CO ~ U(j) ~ .~~ Q) co 0 0 'Of ....., ~ z,' _ 0 uu ::I: u.. ~~ ... 0 Sd' I I I I I I I I I I I I I I I [I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 5 II III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.2 Jack Russell Stadium: Existing land Uses Adjacent to Site I ~ '- CQ)~ ~~ "'Cen C I cu= =~ .- "'C .c ._ :J m~ .c:JCUen 0') ~ Q) .- u.. J: N . N C. CU ~ ~ E ~ (/) ::> ::> .- <vn::"'O :=: co (f).::t:.- u(f) co J (/) <V <V (/)- :JU) "'00 c- co...... ---lC <V OlU C co 00:0- 'x <( w ~ " Q. .2 f/) x :0 c ~ w ~ ~ f1J >.0.. 0:-8- :J Ei=~~ 'Ec ""C (to.... E l:? ro Q) .Q ; ~ i ~ ~ ~ ~ ~ c ...J~~g-:g~=':c~~ ~ 0 ~ 0 ~ U ~ ~ ~ ~ ~~D(lIIDDID ;; " LL o co .. I o N 3 i'l ,; :::is ] C2 U ~ ~~ 0 (Jl? ~ 'Of ~ ~5 UU ~; ~ H_ UJ I '-<rID ~ o .. N o I I I I I I I I I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 6 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I I I I I I General View of the Site I I I I I Jack Russell Stadium I I I I I Greenwood Apartment Complex I Dr. Martin Luther King Jr. Streetscape Improvements '1 I ........ r-"- ~- · -, :-- ":1._ _~~ ~~ 77"'~. -' -- j. '1 ~ ;.~~ Industrial Uses Adjacent to the Site I L__ c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 7 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Public facilities adjacent to the site include the North Greenwood Library and North Greenwood Recreation and Aquatic Center (west of the site). In addition, the Greenwood Apartment Complex is located to the northwest of the site. Major future land uses adjacent to the site include: Institutional, Residential High, Residential Urban. (See Table 2.2 and Map 2.3). Table 2.2 Jack Russell Site: Adjacent Future Land Use Category Number of Percentage Area Percentage Parcels (Parcels) (Acres) (Area) Commercial General 13 14% 1.99 4% Institutional 7 8% 23.83 43% Industrial Light 8 9% 3.47 6% Residential/Office General 1 1% 0.29 1% Recreation/Open Space 1 1% 4.55 8% Residential High 1 1% 8.24 15% Residential Medium 16 17% 2.49 5% Residential Urban 46 49% 10.26 19% Total 93 100% 55.12 100% Source: Pinellas County GIS,2005 Major zoning designations adjacent to the site promote Industrial, Medium High Density Residential, Medium Density Residential (15 dwelling units per acre) and Low Medium Density Residential (7.5 dwelling units per acre). (See Map 2.4) 2.1.2 Projected Development There are currently no projected development projects identified for the Jack Russell Stadium site or area adjacent to the site. The City is looking to develop alternatives to redevelop the site to bring economic development and job growth to the area. 2.1.3 Environmental Constraints. There were no environmental constraints identified for the Jack Russell Stadium site. 2.1.4 Transportation The Jack Russell Stadium site is located 0.55 mile east of the closest launch destination (Seminole Boat Ramp). The corresponding launch route is Seminole Street, a two lane city collector street (See Map 2.5) c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 8 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.3 Jack Russell Stadium: Future land Use Adjacent to Site I ~ ~ CQ)~ .... .... .- "'COO- t: I CU~ M . N C. CU :E ~ E ~C/)::> ::> .- (1)0:::"0 - ro U5~- uU) ro --, C/) (1) (1)_ C/) .- ::::>U) "OE c_ ro c ---l(1) (1) U ...... ro ::> .~ _"0 ::><( LL " ~ ~ E ~~ ~ >- ~ ~~~~~ ~ ~ w ~ ~ I Q ~ ~ 0 .Q ~ ~ ~ ~ ~ .~ ~ ~ ~ ~ ; ~~ii~~.i~",~ -;:~~~&&8~&E~ ~!D[JIIID[J[]D Oi .1:' o <Xl .. I z-\rOO =::: o .. N 'i o ~ ~ ~ .. ~~ ~ . ~a U~ oc "'", _ 0 UU gi fj,~ ~ E2 ~ ~ ... I ~ .- "'C .c ._ ::J tn.... .t:::JcuOO C):E Q) .- LL. ::I: w o N o I I I I I I I I I I I I I I dw2066.01 m\gis-data\reports\feasibility study jan 2007 Page 9 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.4 Jack Russell Stadium: Zoning Districts Adjacent to Site ~ ~ CQ)~ ~~ .- "'COO c: I CU~ g; g 13 ~ -ci -0 c o.~~~ ~ .g~~q, ~ en c l/) ID Q.) $~~O Q; ~ -0 iii -& ~ 1i _ ~ ~ I tj; .~].!~-gi ~ E 2 ~ 0:: :: (( ~ ~ 8 ~ I- 0 '" 0 0 _ !lllaoiiil o ;; W lL o <0 M CJ) Q) -- u .- .;: (f) -0 CJ)_ 0- C O>Q) C U .- en c .~ 0"0 N<!: ~ . N C. CU ~ ~ .; ~ 0( U j~ u 'Of ~g uu ~~ H ::E ~ E--- ~ ~ ... ~ E ~CJ)::J ::J.- Q)O:::"O :::: en (f)~- u(f) en J ~ .- "'C .c ._ ::J tn~ oC::JCUOO C)~ Q) .- LL. ::I: w ,-\>-- ~ o 0> on 0> c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 1 0 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.5 Jack Russell Stadium: Existing laneage along launch Route I >- (/)~ L. ;; >- ~ C Q) Q) :) u. 0 ~ ~ Lt) Q) c 0 Q) '" ;,; Cl m ~ .- .- >- . (/) E roO:::: 11l .. w 'C en - N . . (/) ....J Q) Q) '" '" '" z-<r- ,; :;E .- 'C ..- :) .c l: c: ~ ~ CIl ~ ~ c: I .c :).- .. <: <: <: Q)O::::u O'lu n:s ...J .!!l .!!l .!!l <: CU .- ~ Q, c c ...J Cl '" M "<t U ~ ~ .- :::: ro .!: U> ~ (f).::s:.- :) [ II '" CU - ra u; to- ~ui en u(f) (/) ro ... <3~ ~ .c: ~ CU .)( ~ ~ ro 'x ....J w '" o'E .~~ Q) -, ...: ;,.' w- M _ 0 '" l>l> LL ro 8'; ~ J: ~"ii 0 S.f I I I I I I I I I I II II I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 11 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I I There are 32 parcels along this launch route. Predominant existing land uses of these parcels are single family (34%); vacant (27%); commercial (19%) and public/semipublic (10%). The largest lot frontage along the launch route corresponds to single family and vacant lots. (See Table 2.3) I Table 2.3 Jack Russell Site: Launch Route Existing Land Use I North Side South SIde Total EXlstmg Land Use Number of Frontage Number of Frontage Number of Frontage Percentage Parcels (Feet) Parcels (Feet) Parcels (Feet) Vacant 3 608 5 692 8 1,300 27% i Commercial 3 611 2 296 5 907 19% Single-Family 5 788 6 868 11 1,656 34% Industrial 1 77 1 231 2 308 6% Recreation/Open Space 1 62 1 116 2 178 4% DuplexIT riplex 0 0 1 47 1 47 1% I Total 14 2,270 18 2.588 32 4,858 100% Public/SemI-Public 124 2 338 3 462 10l{, I I Source: Pinellas County GIS, 2005 I I Future land uses along the launch route are mainly Residential Urban (7.5 dwelling units per acre), Central Business District and General Commercial. (See Map 2.6 ) Table 2.4 Jack Russell Site: Launch Route Future Land Use I NORTH SOUTH Total Future Land Use Number of Frontage Number of Frontage Number of Frontage Parcels (Feet) Parcels (Feet) Parcels (Feet) Percentage Central Business District 7 758 6 804 13 1,562 32% Municipal, No FLU 1 63 1 116 2 179 4% Institutional 0 0 1 353 1 353 7% Residential Urban 13 1,042 13 1,088 26 2,130 44% Commercial, General 3 414 3 228 6 642 13% Total 24 2,277 24 2.589 48 4,866 100% I I Source: Pinellas County GIS, 2005 I The use of this site for the proposed High and Dry Boat Storage will require mitigating transportation impacts such as traffic, noise and road wear along the launch route and adjacent major roads. Another concern will be providing transportation means for the high and dry users from the proposed site to the Seminole Boat Ramp. I I I I I I c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 12 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.6 Jack Russell Stadium: Future land Uses Adjacent to launch route I I ~ L. CQ)~ ..... ..... -Cen C I ns~ ~ .- -C .c ._ :s W..... .c:snsen C') ~ Q) .- LL. J: U) . N c.. ns ~ E ~ .:? u-o ro ro ...., ....... ..(f) w Z-\r" ~ o '" .. ~ .,; ::E j E2 I~ ~ ~~ l5 ~i ~~ ~g UU ~; ~ H_ I "'"""= Q) Q) .......(/) (f)~ 0::: (/) Q) Q) (/) ..... ::JO::J ""'0 -0""'0::: c c roQ).c ---lUU ro Q)'~ c ~-O::J ::J <( ro ....... ---l ::J u.. 5: => '0 C u ., !O ~ ~ c Cii i:5.2 <<l c: U):::J ~ 5~ ~~ ::J .;;; Z -g ~ 1 l .E ~ ~~~g~i:~ i!Dloio ;; '" u.. o N 0> o '" N o I I I I I I I I I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 1 3 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 2.1.5 Infrastructure Availability The Jack Russell Site has good provision of infrastructure services since the site is located within the urban fabric. The site has access to potable water lines owned by the City on Dr. Martin Luther King Jr. Avenue (West), Palmetto Street (North) Street and Seminole Street (South). Reclaimed water lines and water fixtures run along Dr. Martin Luther King Jr. Avenue and Seminole Street (South). In addition, storm water lines are available along Dr. Martin Luther King Jr. Avenue, Palmetto Street and Seminole Street. A stormwater pond is located in the northwest part of the site along Palmetto Street. Wastewater collection and transmission lines are located along Martin Luther King Jr. Avenue, Palmetto Street and Seminole Street. Additional stormwater facilities would be required by the City and SWFWMD to accommodate development on the site Maps 2.7, 2.8, 2.9 and 2.10, show the provision of infrastructure services to the Jack Russell Site. 2.1.6 Neighborhood Compatibility The Jack Russell Stadium Site is within a consolidated urban area north of the Downtown District. It is bordered by an industrial and commercial area (South of the site) as well as by single family and multifamily housing. The adjacent neighborhood has been the target of numerous planning efforts and investments as a means of revitalizing the existing fabric and improving the conditions for existing residents. Some of the most recent City investments are: . The North Greenwood Recreation and Aquatic Complex · The North Greenwood Library . The Dr. Martin Luther King Avenue traffic calming and streetscape improvements . The expansion of the reclaimed water system into the neighborhood Over the last five years, the Jack Russell Stadium Site has been the subject of discussion for redevelopment. Any redevelopment proposal should take into consideration important issues raised by neighborhood residents such as building scale and architectural character, as well as traffic and noise. . According to the North Greenwood Economic Redevelopment Strategy prepared by the Economic Development Department of the City completed in 2003, some of the potential uses recommended for the Jack Russell Site were: . Health Care Uses, particularly assisted living for the lower income elderly population and related health care facilities to serve neighborhood and area residents while providing on-site employment opportunities. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 14 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.7 Jack Russell: Stadium Potable Water ~ Q; '" L. (/) lL ~ Q) 0 C Q) '- <:: 0 Q) ::J " .... .... ..... Q) ...... ~ ~ . E m C:- Qj " en en S m ~ UJ ;:;s .- " N ~ en -c '-\roo '" :J <:: !! ~ c: I .0 :J .- :l t .- ::::J C. Q) 0:::"'0 Q) 0 Q) <( ~ CU ...... Ol :c ~~ .... .- m 0 U> .... (j) .0 .~ m 0 CU .:x. ...... (5 N ~ . J: ::::J CU en U(j) m V> 0- ~5 ~ ~ ...... ~ u~ .~~ Q) m 0 []I 0 oC: ~ ~, J CL .~ 0 uu J: LL ~~ ... 0 ~~ c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 1 5 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.8 Jack Russell Stadium: Reclaimed Water ~ Q; ..... ~ .. ~ u. ~ Q) ::> Q) 0 C Q) - x c 0 u: :.:::; ... .., .., CO ro i .- ~ . Q) E S Q; Q; -C CJ) ~ ~ UJ ;:;s UJ .- -C N CJ) c:- z-</-. " ::l "0 III ~ 02 t: I .c ::l .- '0 '0 '0 Q) Q) c Q) Q) <( . .- ~ c. - 0:::"0 ::> E E ~"' E-- CO .- E 0 0 *~ .., tn .., (f) ro CD '0; '0; 0 t=:l CO .:::t:. - "0 "0 N ~ . J: ~ CO UJ ()(f) ro ~ Q) Q) ~~ 0 ~ (/) 0: 0: ~ ~'" ~ .~~ Q) ro () Do I 0 o c J Q) 5:! "'~ _ 0 UU LL 0::: i\.i'" :I: ~~ ... 0 So: c1w2066.01 m\gis-data\reports\feasibility Sludy jan 2007 Page 1 6 I I I I I I I I I I II I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.9 Jack Russell Stadium: Stormwater ~ Q; ., ~ u- ~ C1> "0 0 C CD <= 0 0. 0 '" ...... ...... 0') '- c:- o:: a. ~ .- .- ~ Q) E Q) III Q; Q; "C - . (/) ....... "0 W ::;s CJ) N ro <= ;;; ;;; .; .- "C .,.- (/) :::J z-<r. ::J 3 0 ;;: ;;: ~ i:2 c I .c Q) ::J-- m E E .- ::::s c. IY"O E <( . E--< C'O .- ....... 2 .8 .8 "''' 0 ~~ ...... en ...... Cf) ro '- Ui 0 ~ . w C'O ..::s::........ lIJ lIJ N CJ) uCf) 0 []\ ~~ Cl .c ::::s C'O :E ....... D ~ ~ .~:E CD ro Cf) 0 o~ S' l;-' -, _ 0 UU LL iaj'" :I: 0'" ~ ". 0 ~cr c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 1 7 I I I I I I I I I I I I I I I I I I. I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.10 Jack Russell Stadium: Wastewater ~ c;; Vl ., L- ID LL ~ 0 C (1) 0 Vl Q; 0 Q) " .... .... L.- a. iii .- .- ~ ~ Q) Q) ~ a: ....J ~ -c - (f) E - III Q; UJ ~ en .- -c .,...- (f) ro "0 Q; iii Z~W ~ N ::l ~ c ro !! 52 s::: I .c Q) ::l'- :> 3: 1: ;;; ~ 0:::"0 0 " . CO .- .- - Q) III Q) Q) "'" ~ .... C. ro - en en 0 ~~ tn .... Cf) 2 0 ~- (f) ~ ~ N ~ . en CO in mOO ~ .c ~ CO uCf) ro 5(3 :! ro S [] I] ~ ~ 'Of .~:! (1) 0 ~ ""~ ...., _ 0 t)U :I: LL ~~ ... 0 S,f c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 1 8 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Multifamily Housing, including for-sale town homes and rental apartments primarily targeting the needs of low and moderate income households. Mixed or Multiple Uses, recognizing that the 16-acre site is large enough to accommodate two or more urban uses." The City is still studying the best re-use of this site, which is as previously noted one of the largest vacant properties in Pinellas County, a county where land scarcity has become an issue. . Educational and Training Uses, including occupational training for youth and adults, extension courses and home and family education and counseling services. Industrial and Service Uses, including one large user or multiple small firms in owner occupied or multi-tenant buildings involved in light manufacturing or service-type activities, such as building maintenance, security, pest control, cable services and heating and air conditioning contracting. Office Uses, particularly small users in multi-tenant flex/office space. Sports, Recreation and Entertainment Uses, including retention of the stadium and related open areas as a public asset for amateur baseball!softballleagues and tournaments, other outdoor events and recreational uses . . . . . The proposal of a high and dry facility at this site may have to contented with the identified neighborhood concerns (character, traffic, noise, etc.) as well as competition with other redevelopment proposals that could generate larger sources of revenue and future job growth within the North Greenwood Neighborhood. 2.2 Stevensons Creek Shuffle Board and Lawn Bowls Complex (Site 2) 2.2.1 land Use, Zoning and Code Provisions. The Stevensons Creek site is located at the intersection of N. Fort Harrison Avenue and Calumet Street just south of the Ft. Harrison Avenue Bridge crossing Stevensons Creek. This site is also located within Neighborhood District II of the City of Clearwater. The site is approximately 8.41 acres in size and is owned by the City. The existing use of the site is recreational and open space, currently hosting the City's Lawn Bowls and Shuffleboard Complex. Although the site has significant shoreline on Stevensons Creek, the site is not currently oriented toward the water or water-related activities. Adjacent submerged lands are believed to be owned by the State of Florida. The future land use designation for the site is Recreation/Open Space and it is zoned as Recreation/ Open Space (R/OS). Page 19 c1w2066.0l m\gis-data\reports\feasibility study jan 2007 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study The proposed high and dry facility will not require changes in land use and zoning designations since it is considered a recreational use. The immediate area of influence of the site is about 8.43 acres. Predominant existing land uses within the site's area of influence are: single family residential, commercial and multifamily residential. Commercial activities are located west of the site along N. Ft. Harrison Avenue, while residential uses are located towards the south along Calumet Street. (See Table 2.5 and Map 2.11) Table 2.5 Stevensons Creek Site: Adjacent Existing Land Use Category Number of Percentage Area (Acres) Percentage (Area) Parcels (Parcels) Single-Family 26 84% 5.10 61% Duplex-Triplex 1 3% 0.19 2% Multi-Family 1 3% 0.86 10% Commercial 3 10% 2.28 27% Total 31 100% 843 100% Source: Pinellas County GIS, 2005 The commercial activities towards the west of the site are related to condominium and seasonal rental units on property owned by the Church of Scientology. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 20 I. III WADETRIM I Map 2.11 City of Clearwater High and Dry Marina Multi-Site Feasibility Study Stevensons Creek: Existing land Uses Adjacent (200') to Site I ~ L. CQ)~ ... ... - ~';; = ~ - v, .- 'C C I .0 tV ~.- :J ",'" oC:JtVcn C)~ Q) .- L1. J: ~ a.> a.> '- U Nc a.> 0 (J) (j)c a.> > a.> ...... (j) 'or"'" 'or"'" I N Co tV ~ I I I I I I I I I I I I I I (J) a.>.- (J) - :)0 o "DNa.> c-...... ro......Ci) -.JC a.> 0 O'lu...... C ro u;:o 'x <( w " '" u. o re Ql x ~ en Q) .{g=> c.~ c: "C n; ~ ~ OE ~; .~.~ 0 (1. N...J E '-+ ~ Q.l i!!Cl~~:,gg.~ ~~JiiDD g ~ ,; ::;E j E2 t~ ~ J?<l ~ n ~ t>t> ;> ~.; ~ H_ w z-<r. ~ o .. o ... o I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 21 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I I I I Stevensons Creek I '" I - - I I \ ~ -~- I I . - Existing Bridge Over Stevensons Creek (View 1) .. - - I I I I North Fort Harrison A venue (West of Site) I I I I Shuffleboard & Lawn Bowls Complex Page 22 I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Stevensons Creek I , ..... ---- ...-~ ,. Existing Bridge Over Stevensons Creek (View 2) Calumet Street (South of the Site) Clearwater Shuffleboard Club I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Major future land uses adjacent to the site include: Residential Urban (7.5 dwelling units per acre) and Resort Facilities High (30 Dwelling Unit per acre and FAR 1 .2). (See Table 2.6 and Map 2.12 ) Table 2.6 Stevensons Creek Site: Adjacent Future Land Use Source: Pinellas County GIS, 2005 Zoning designations adjacent to the site promote low medium density residential (5 dwelling units per acre) and tourism. (See Map 2.13) 2.2.2 Environmental Constraints The site includes approximately 1,500 feet of mangrove shoreline averaging 30 feet wide, from the most waterward tree to the most upland tree (See Map 2.14 or Appendix). Other shore vegetation at the site is comprised primarily of sporadic oak trees, palm trees and exotics such as Brazilian Pepper. Such presence of a continuous mangrove shoreline would require a permit from Pinellas County Environmental Management to remove and trim mangroves at the site in order to facilitate development. Some mangroves may be protected completely from trimming or impact by this permit. No seagrasses were observed during a field survey conducted by Delta Seven, Inc. in March 2006 (See Appendix 1). The State of Florida will likely require a seagrass survey during growing season to verify that seagrasses are not present should this site be selected. Water depth is a constraint at the Stevensons Creek site (See Bathymetric Survey in Appendix 2. This survey was conducted in concert with the Stevenson Creek Environmental Restoration project). If navigation is desired to and from the site, dredging will be necessary. Depths at the site are less than the required three feet of water at Mean Low Water. Permits will be required and obtaining such permits may prove difficult, especially within an Aquatic Preserve such as Stevensons Creek. Additionally, the bridge to the north of the site significantly limits the height of vessels entering and exiting Stevensons Creek to very low profile vessels. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 23 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.12 Stevensons Creek: Future land Uses Adjacent (200') to Site ~ .:::.::. rJ> ~ Q) Q) ---.. ..r: v Q) ~ '" " C N Q) rJ>e, I u. c 0 ..... ..... "- :)0 >- .. '" ., ~ .- "'f""" 0 i;; (II -e Q) N .- ~ "0 ~2 1II ::J ~ w f;l ::s "C en - '0 ::> .,; c '13 "-\roo .- "C N N C C .- ::> Iii .. ~ ~ C I .c 0 co~(/) 0 '0 .E "- Q) lD c: Q) '" ~ to ~~ ~ CU .- .- - rJ> --l N III '0 0 ..... c. Q) 0 .& -' ~ in '" J ~ fn ..... c Q) Q) 0 en (/) Q) Q) u- Vi (II 0 0: 0: ;! j~ ~ J: ~ CU CU > "- co D~ JOI ~ ~~ :E :J .~ .~:E Q) Q) _"0 0 l;-' - ... _ 0 :J<( UU U. (/) " . LL 0-" ... J: 0 ~~ c1w2066.0l m\gis-data\reports\feasibility study jan 2007 Page 24 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.13 Stevensons Creek: Zoning Districts Adjacent to Site I I ~ L. CCD~ .... .... .- .- 'O(/)- C I ns~ (II') ~ ~ Q) Q) '- en Q) ...... ...... u .- .~ en eno .- ...... 0...... C 0lQ) C U .- co C .~ 0-0 N<( .,; c: "0 (ij .2 Q) ~ (0 a:: '" '" oj ~ M c: '" a:: ~ cr 'OJ ,,<Ii ~ ~ ~~ ~5 ~ ~ c ~ 5 o~ ~i::E ~ ~ ~ ~ 0 ~ .~ N ~ a:: ~ ~ ~ ~ .!! :E01(fj1. ~JIDD[]iiD "$ LL o 00 '" I ~ .- '0 .c ._ ::::s tn.... J:::::Sns(/) O)~ CD .- LL J: z-<?-. ~ o ... ~ j ~ U ~ ~~ ~Q ~~ ~ 00 ~5 u<.> .., ~ !5~ Sa: N C- ns ~ o NC Q) 0 en enc Q) > Q) ...... en UJ o ... I I I I I I I I I I I I I I c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 25 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.14 Stevensons Creek: Site Initial Ecological Assessment ~~#~ Mangrove dominated shoreline ~ Navigation limited by depth Stevenson Creek site o I 125 250 I 500 Feet I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 26 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 2.2.3 Projected Development There are three development projects proposed or recently completed in proximity to Stevensons Creek site (See Map 2.15): . 1925 Edgewater Drive: Bayview Condominiums, which proposes 62 residential units to the north across the creek from the site, . 1860 Fort Harrison Avenue: Villa del Mar, which proposes 24 residential units at the northwestern edge of the site (project is complete), . 308 Venetian Drive: Venetian Cove Townhomes, which proposes 6 residential units to the southwest of the site. In total 92 additional residential units are approved for the area surrounding the site. 2.2.4 Transportation The Stevensons Creek site is approximately one (1) mile north of the closest launch destination (Seminole Boat Ramp). The corresponding launch route is composed of two roads: . North Fort Harrison Avenue (0.96 mile), a minor arterial under the City's jurisdiction and . Calumet Street (0.04 mile) which is a local city street of two lanes. (See Map 2.16) According to the Pinellas Metropolitan Planning Organization in 2005, Fort Harrison Avenue operated at level of service C or better. North of the bridge at Stevensons Creek, Edgewater Boulevard operated at level of service F. These levels of service should be taken into consideration as constraints when proposing a future High and Dry facility at Stevensons Creek. Predominant existing land uses along the described launch route are commercial (42%); single family (17%), duplex/triplex (12%), vacant (11 %) and public/semipublic (10%). c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 27 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.15 Stevensons Creek: Adjacent Approved Projects I ~ (J) L. ....... CQ)~ U CIl It') (1) 1:' 0 .... .... II> c: .~ ll> '0' .- ~ ~ 0 .......0 '0 c:: 'Ct/) c: "- c N (J)..::t:. :::J .- 'C N (1)0.... 0 '0 c: I c: (1) []) II> .c (1) (1) (1) U-o 15 CO:;:; .- ~ N C. > "- .~ (1) ~ a. fn"" (/) (1)0 Cl -0> en <( .c: ~ COt/) CO ....... <C 0 [0]1 :E (/) "- en:E Q) 0- .- u.. 0- J: <C I I I I I I I I I I I I I I I v '" u.. 0 ill w z-<?-. 0 ~ ~ '" '" ~ ~ I ~ ~ ~ ~ 0 ~ " ." ~\1!; ~ ~~~ ~ lllOOfr 0 ~H ~ 58~ ;> Hiii I c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 28 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.16 Stevensons Creek: Existing Laneage along Launch Route I I ~ .::s::. (l) (l) Q; ~ '" (l) 0>- I/) lL C Q) ~ (l) Q) 0 (0 cu ::> 0 ... ... '- (l) 0 t: CI.I "! 'i 0 Cl 0 .- .- ~ ~ ccr: ca l\l W ~ "C en - ...J CI.I '" '" '" .,; ::E .- "C N C CU..c l: '" '" Cl> z~. ~ N l\l c: c: c: l:2 c I .c 0 -lu M ...J .!l1 .!l1 .!l1 ::J (l) - ClN '" " -< E-- .- (/) I/) ~~ C'CS .- C. - o>C ~ 0 ... tn ... c ::> Q) I II 0 ~ . ~ (/') (l) c t: .. "' olll ~ .c: ::J C'CS en C'CS .- cu ca .;( :i: ~~ > cn-l w ~ (l) ...J 8 o 0 .~~ Q) >-' := 0 - x- '" UU LL (/') WCU r' ~.; ~ J: :;ii 0 S,f I I I I I I I I I I I I I I I c1w2066.0l m\gis-data\reports\feasibility study jan 2007 Page 29 I. III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Table 2.7 Stevensons Creek Site: Launch Route Existing Land Use I. WEST EAST Total EXisting Land Use Number of Frontage Number of Frontage Number of Frontage Parcels (Feet) Parcels (Feet) Parcels (Feet) Percentage Public/Semi-Public 1 531 3 438 4 969 10% Vacant 7 483 10 627 17 1,110 11% Multi-Family 4 310 0 0 4 310 3% Commercial 24 2,560 15 1,550 39 4,110 42% Single-Family 6 442 21 1,198 27 1,640 17% Industrial 2 229 0 0 2 229 2% Recreation/Open Space 2 39 1 317 3 356 4% DuplexIT riplex 5 397 8 744 13 1,141 12% Total 51 4991 58 4874 109 9865 100% I I I I Source: Pinellas County, GIS, 2005 I There are 109 parcels along the launch route. The largest lot frontage along the launch route corresponds to commercial uses and single family residences. (See Map 2.17) Future land uses along the launch route are mainly Commercial General, Residential Urban (7.5 dwelling units per acre) and Resort Facilities High (30 dwelling units per acre, FAR 1.2). (See Map 2.18) I Table 2.8 Stevensons Creek Site: Launch Route Future Land Use I WEST EAST Total Future Land Use Number of Frontage Number of Frontage Number of F rontag e Parcels (Feet) Parcels (Feet) Parcels (Feet) Percentage Central Business District 3 574 7 417 10 991 10% Institutional 1 355 0 0 1 355 4% Commercial - General 37 2,900 33 3,077 70 5,977 62% Resort Facilities - High 10 989 0 0 10 989 10% Residential - Urban 0 0 18 1,268 18 1,268 13% Total 51 4818 58 4762 109 9580 100% I I Source: Pinellas County, GIS, 2005 I 2.2.5 Infrastructure Availability I The Stevensons Creek Site is adequately served by infrastructure services. The site has access to potable water lines owned by the City along N. Ft. Harrison Avenue (West) and Calumet Street (South). Reclaimed water service is not available at the site or surrounding areas. Stormwater collection facilities are available south of the site at Calumet Street and within the site itself. Wastewater collection and transmission facilities are located along N. Ft. Harrison Avenue and Calumet Street. I I I I I c1w2066.01 m\gis-data\reports\feasibilitystudy jan 2007 Page 30 I I I I I I I I I I I I 'I I I I I : I I. III WADETRIM City of Clean1'ater High and Dry Marina Multi-Site Feasibility Study Map 2.17 Stevensons Creek: Existing land Uses Adjacent to launch Route ~ ~ en ;; ~ Q) Q) Q) Q) Q) ~ If) Q) 0 "- C I' Q) .. 0 :J Q. N .... .... "- 0 ::> .!1 If) ~ .- .- ~ U - ClI x :0 c ~ "0 0 Ul Q) => " w "'C en - cc~ => ~ ~ ~ Q. z-<?-. ,; ::E .- "'C N N C "C E .= ~ ;;; E Q ~ ~ s::: .c roQ).!:; E 'u c I Q) 0 c: .. 5 ~ ;;; " .2 <( .- ::::J ...J()() lU "- x .. ~ !Q c;; !;~ ~ C'G .- C. - en ...J " " ~ .!1 " E .... tn .... c O'J.~ c ~ 0> Q. E => :0 t .. 0 ~ (f) Cl c => '5 0 '0 => Q) 0 :g ~cri ~ en C'G Q) C"O ::> ~ 0 ill 0 ::;; u c Q. D:: ~ ~~ .s::: ::::J C'G > :;:: <( ro Ul !DDIIDDID ~ :E Q) Ox 0 o 0 .~:E Q) en ...J <0 "'~ _ 0 - W N uU u.. (f) x 8'; ii :I: w "'}i 0 Sa: c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 31 I I I I I I I I I I I I 'I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.18 Stevensons Creek: Future land Uses Adjacent to launch Route ~ C... (1) ~ .., .., - ~';; = ~ ..., VI .- "C c: I .c CU ~.- ~ W.., J:~CUcn C) ~ (1) .- LL. ::I: Q; ~ lL o N ~ Q) Q) '- o Ne Q) 0 _en (f)e Q) > Q) - (f) en Q) Q) en _ :JO:::l -0 -O-a:: e e roQ),L: --lUU ro Q)'~ e '- -0 :::l :::l <( ro - --l :::l u.. ~ ~ c: r ~ D.. C"ll l1J C l1J g: 5~<3 ~ :::> ~.umm.~ "C 'E ~ "E .~ m C Q) (V ro I'll 'OoE2J= ...J~'~:g;; i!Diioi co "'f"'" w ~ /;l J ~ u ~ H ~~ ~g UU ~jp ~ H_ z-<r. ~ N C. CU ~ o '" '" o ~ o c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 32 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Maps 2.19, 2.20 and 2.21 show the provision of infrastructure services to the Stevensons Creek Site. 2.2.6 Neighborhood Compatibility The Stevensons Creek Site is within the Navajo Park Neighborhood. The area is comprised of single family residential and condominiums along the shoreline. Considering that the proposed High and Dry facility implies an enhanced level of activity (noise, traffic, etc.) than the City's Lawn Bowls and Shuffleboard Complex, it is expected that the neighborhood may show opposition to the project. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 33 I I I I I I I I I I I, I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.19 Stevensons Creek: Potable Water Q; '" >. ... 1Il 0 ~ (lJ l(J Q) >. '- c C en Q) :::i ..., ..., c:: .- Qj ~ ~ .- .- >. 0r- a ro ~ ro W "C U) - S "0 Z-\r. N :::s .- "C N cn.:s:. c ~ N Q) ::l !! ~ t: I .c c:: (lJ . Q) Q) ::0 0 '" "" .- ~ .- Q) Q) al N ~~ ~ CO .- C. > '- - ro ..., fn ..., (/) .0 '0 2 Q)O (ij ~ . U) CO ro 0- m'" ~ .t: ~ CO .- I[) s: '" .!la (/) .- u~ ~ N a '" oc .~~ Q) a.. -~g uu LL ..~ ... :I: 5i .g~ c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 34 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.20 Stevensons Creek: Stormwater '" ;; Q) '" ~ .~ ... '0 ~ ~ C N Q) ~ ::> C 0 0 ...... ...... ... m N c (1) c ;,; .- .- ~ Q) 'w w ~ "C - 0 ....... a. z-<?-. ~ en . N cn.:::t:. ro >- ii: III ~ .- "C N Iii m ~ C I .c c (1) ~ Q; Q; ~ (1) (1) '0 '" " .- ::::s (1) E c Cii Cii ~ CO .- ....... ::> ~ ~~ ...... a. > ... 0 :;: :;: en ...... (f) (1)0 ... m E E L ~ en 0 mOl ~ .c ::::s CO CO ....... ....... 2 E E ~ '" ~a ~ (f) (f) i:7i (/) (/) N 'O? .~~ Q) 01 '" '"', D _ 0 uu LL ~.~ ... J: ~= , . bld' c1w2066.Olm\gis-data\reports\feasibility study jan 2007 Page 35 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.21 Stevensons Creek: Wastewater '" '" ~ u. '" 0 ~ m l(J ~ Qj '" C Q) Q) 'or"'" '- ro 0. .... .... c ~ a: ~ .- N (I) -.J W ~ 0 +-' co Qj Qj "OUJ - "0 z-<?-. :;s . N (j').:x. ro c:: ro ro ~ c: .- "0 N c (I) ~ ::J ~ ~ ~ l:2 I .c (I) 0 (I) (I) (I) a:l Q) Q) '" '" ~ cu:;: ._ :J +-' u; u; ~ ~ c.. > '- +-' 2 I fA.... (J) (1)0 (j') ~ ~ w cuuJ CU ro iii ~ ~ .c :J +-' []I ~ '" (3 ~ (J) s ~ N '0 .~~ Q) '" ~ u L1. ~ J: ~ ... ~ c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 36 I I I I I I ,I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 2.3 Seminole Launch Ramp (Site 3) 2.3.1 Land Use, Zoning and Code Provisions The Seminole Launch Ramp Site is located west of Osceola Avenue, at the end of Seminole Street at Clearwater Harbor and the Intracoastal Waterway. This site is also located within Neighborhood District II of the City of Clearwater. The site is approximately 5.9 acres in size and is owned by the City of Clearwater. The site has significant shoreline and it is currently used for water-related activities. The existing use of the site is recreational and open space and includes a boat ramp facility and large parking area for boat trailers. There is a parcel immediately adjacent and to the west of the site that is owned by the West Coast Inland Navigation District and currently functions as a small passive park. The future land use designation within the Downtown Redevelopment Plan for the site is Central Business District. The site is currently zoned as Recreation/Open Space (R/OS) allowing uses such as Public/Private Open Space and/or Recreation Facility; Beach/Water Access. The immediate area of influence of the site is about 10.63 acres. Predominant existing land uses within the site's area of influence include: commercial, vacant and multifamily. Most uses are aligned along Osceola Street. There are only three single family residences within the site's area of influence. (See Table 2.9 and Map 2.22) Table 2.9 Seminole Boat Launch Ramp: Adjacent Existing Land Uses Category Number of Percentage Area Percentage (Area) Parcels (Parcels) (Acres) Vacant 1 6% 3.59 20% Commercial 7 41% 9.48 53% Duplex-Triplex 1 6% 0.15 1% Marinas 1 6% 0.70 4% Multi-Family 2 12% 2.06 12% Public/Semi-Public 2 12% 1.56 9% Single-Family 3 18% 0.27 2% Total 17 100% 17.82 100% Source: Pinellas County GIS, 2005 c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 37 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.22 Seminole Boat Ramp: Existing land Uses Adjacent (200') to Site ~ L. CQ)~ ..., ..., - ~~ = ~ '-' VI -- "C C I .c CO :;.- ::::J en"" J:::::JCOcn C'):E Q) .- u.. J: (/) Q)---.. (/) - ::)0 o "DNQ) c""""'- ro-U) .....I c Q) 0 OlU_ c ro ~U 'x <( w Q; " lL o '" N N N . N C. CO :E " n; cu ~ u ~ >-~ ~~ 'C ~'::~n;EE ~ ~ 0 ~ e ~" 0 w ~ ~ ~ ~ ~ ~,,~ ~ ~ .~ % ~ g ~ ~ .Eg,()jo::;oa.~::; ~~D[]II[]DD n. Q) E c.-;oro Q) .~ 0::: -E- .- ro (/)Q)o (/)co ~ ~ J ~ u ~ ~tri 0 ~~ ~~ o < ~5 00 H~ w '-<roo ~ o '" on '" o c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 38 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I I I I I I View to the Boat Ramp I I I I Launch Facility at the Site I I I I Adjacent Single Family Residential I I I View to the Boat Ramp Francis Wilson Theater Property . '..' ~ '. ~..:o.-.~I'''' I' ..... a ,.,. ... ..... ., .. . 111 :-~l - il Ii <' "r.!!'= ... -.' -..... I r.;,. _lJIIOOt H .... ." ... Ir'l~. .."" II ~ 700 Osceola, Bayview Condominiums I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 39 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study The future land use for parcels adjacent to the site is Central Business District. The Downtown Redevelopment Plan permits Residential; Office; Retail; and Public/Semi-Public uses in the Central Business District. Table 2.10 Seminole Boat Launch Ramp: Adjacent Future Land Use Central Business District Source: Pinellas County GIS, 2005 The area immediately adjacent to the site is zoned Downtown (D) and the shoreline of the site is zoned as Preservation (P). The proposed high and dry facility is recognized as marina/marina facilities which are allowed within the Downtown Redevelopment Plan as a Flexible Development (FLD) use, requiring Community Development Board (CDB) approval. 2.3.2 Environmental Constraints Due to the existing use of the site, environmental constraints at the Seminole Boat Ramp are limited. The property is bounded at the water by an existing seawall and no mangrove vegetation is present. The seawall is largely intact except for a small 50 foot area just west of the existing launch ramp that is covered with palms and shore grass. In March 2006, Delta Seven, Inc. conducted a cursory environmental assessment of the site (See Appendix). No seagrass beds were observed within the submerged lands immediately south of the boat ramps and southward toward the southern seawall of the property. At the southern seawall of the property and extending south of the seawall is a small linearly oriented oyster bed established on submerged debris (See Map 2.23) Approximately 100 feet south of the southern seawall of the site is an extensive seagrass bed that extends southward toward the Drew Street Fishing Pier (See Map 2.23). The seagrass bed covers the extent of the shallow flats in this area and would severely inhibit the development of a marina facility within the confines of the grass bed; however, this grass bed does not extend into the basin at the base of the existing boat ramps. Therefore, it is not likely that the seagrass bed will impede the permitting of accessory docks or boat launches associated with a high and dry facility. Also due to the existing use of the Seminole Boat Ramp site, water depth is not a constraint so long as boat launching and navigation activities do not change significantly from their current patterns of ingress and egress. Water depth along the western seawall near the parking lot is sufficient to allow the construction of docking facilities for use by boats launched from a high and dry facility. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 40 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I I Map 2.23 Seminole Boat Ramp Site Initial Ecological Assessment I I I I I I I I I I I I I I I o I 200 400 I 800 Feet I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 41 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 2.3.3 Projected Development There are three development projects approved or under construction around the Seminole Boat Ramp site (See Map 2.24): . 900 Osceola Avenue: Clearwater Bay Marina Condos with 133 residential units at the northern edge of the site. (currently under construction). . 700 Osceola Avenue: Bayview Condominium with 28 residential units (finalized) at the south edge of the site. . 609 Seminole Garden St.: Trail Townhomes with 36 residential units to the east of the site. In total, 197 residential units are anticipated for the area surrounding the site. Most of these developments are waterfront condominiums with a Mediterranean architectural style, ranging from approximately 9 to 12 stories in height. Development of a high and dry marina at this site would require the facility to blend architecturally with the recently approved projects. 2.3.4 Transportation The selection of the Seminole Boat Ramp Site to build the High and Dry facility, eliminates the need for a proposed launch route, considering that boats will be stored and launched at the same location. However, some transportation impacts may be created along two major thoroughfares: . North/South: Fort Harrison Avenue and Myrtle Avenue (currently under expansion). Both of these roads are considered minor arterials and operate at level of service C or better. . EastlWest: Drew Street, also a minor arterial that operates at level of service C or better. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 42 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwaler High and Dry Marina Multi-Site Feasibility Study Map 2.24 Seminole Boat Ramp: Adjacent Approved Projects ~ (f) ;:; " ~ - IL 8 C Q) ~ U '" e V Q) '0 e ~ .., ~ Q) '" ;.; .., N 0.. l'D '0 0 I .- ~ Q) E - 0 '0 n.. UJ ~ ::E "'C en . c l.- e: '-<roo ,; ! (Y) 0 ::J .- "'C N CU Q)Q.. 0 '0 ~ ~ t: I .c .:= 0::: CD Q) . 0 Q) U-o > ~g.~ ~ ~ 0 ~ .- - E- o. e CO .., .- c.. .~ Q) ~ e ~ ~- ~ ~ fn .., (f) C. N Q) CU -0 > en <: . "'Ii: ~ en CO .fall .c ~ CO (f)0 <( 0 DI s: ~EJ :! en l.- e .~:! Q) ~ ~'" 0.. 68~ LL 0.. . ~o ~.!51o ... J: <( e ~~,~ 0.0 c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 43 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 2.3.5 Infrastructure Availability The provision of infrastructure services within the Seminole Boat Ramp site is not a concern. The site has access to potable water lines owned by the City along Osceola Avenue. Additional potable water lines are available along Seminole Street and throughout the site. Reclaimed water service is not yet avai lable for this site. Stormwater facilities are available from Osceola Avenue down to the bluff. Wastewater collection and transmission lines are available along Osceola Avenue, a portion of Seminole Street and Eldridge Street. Maps 2.25,2.26 and 2.27 show the provision of infrastructure services to the Seminole Boat Ramp site 2.3.6 Neighborhood Compatibility The Seminole Boat Ramp site is within the Downtown Redevelopment Plan, specifically the Old Bay District (See Map 2.28). This area is composed of a mix of residential land uses (including single-family dwellings), recreational, governmental, industrial, commercial and institutional. The District's unique character is due to its location along Clearwater Harbor and the significant number of older structures. According to the Downtown Redevelopment Plan, the Old Bay District "is envisioned to be a mixed-use neighborhood supporting the Downtown employment base with residential, limited neighborhood commercial and office uses. A variety of densities and housing styles are encouraged throughout the District, as well as renovations of existing older structures". The Plan also states that there should be an emphasis placed lion tying the eastern and western sections of the entire District together by providing linkages between the waterfront and the Pinellas Trail. Public improvements to the Seminole Boat Ramp will also enhance waterfront access and appearance." The plan specifies two policies regarding to the site: . "Policy 3: The Seminole Street Launching Facility should be maintained as a recreation site, recognized as an area attraction and should be improved with the addition of elements such as picnic areas, park benches, landscaping, lighting and parking management," and · "Policy 4: City rights-of-way that dead-end at the harbor shall be retained and improved for public access to the water." According to the plan there is a priority to provide waterfront access and water related activities at this site. The high and dry facility would meet both of these priorities. Consideration should be given to co-relate the character of the proposed high and dry facility with the existing and proposed condominiums and other historic structures within the area. Views from the bluff and the improvement of landscaping are also important with the redevelopment of the site. c1w2066.Olm\gis-data\reports\feasibility study jan 2007 Page 44 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I Map 2.25 Seminole Boat Ramp: Potable Water I I >. ;; l/l " L. "- >. Q) 8 C Q) It) '- c: Q) ::J N ... ... 0.. ;,; N ...... ~ Qi 0 .- >. Q) E co w ~ "Cen . S ro - '-<roo .. ;:;s .- "C N C") 0 co -g ~ ~ ~ c: I .c Q) . ~ 0::: 15 ~ <( ._ :::::s Q) j~ ~ ns~ Q, ...... E...... al.c 0 en'" (j) .D Q) .!!! ~ Q) co (too ~ nsen ns co "" 0 ~~ .1: :::::s (j)O ...... (/)ll. ~ ~ co 0 III 0 00 .~~ Q) '" ;,.~ CL _ 0 UU LL 8; ... J: 0 ~!i Jla: I I I I I I I I I I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 45 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.26 Seminole Boat Ramp: Stormwater ~ " " ~ u. Q) ~ 0 C CD Q) :<l .... .... n. '- a. ~ .- .- ~ N Q) E Q) ~a:: w l<1 "'C en - . -- ro z~w .,; ;:;E .- "'C N (Y) 0 ro ro '0 Q5 ~ i:2 c ~ c - I .c Q) .~ 0:: :J ro << .- ~ -- E o 3: 0 ~~ E-- CO .... .- C. E-- [!} E ~ l ~ tn .... (f) ro '- Q) ~ i~ en Q) 0 "" .9 ~ .c ~ CO CO (f)o -- rnrn ~ u<;. :E (() (f) []I 0 oi: .~:E Q) on lo' _ 0 UU LL. 8'; ~ :::I: 0 H c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 46 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.27 Seminole Boat Ramp: Wastewater ~ ~ CQ)~ to- .... .... 0.. '- .- ~ N (!) E (!) - "Crn . ro .- "C ('f) o ro r:: I .c N (!) .~ a:: ~ CU~ .- ~ a. - E- (!) rn.... - (f) (!) ro en ~ ~ CUm CU (f)o ro C):E Q) :E CD S .- LL. :I: Q; IJ) <I> ro IL IJ) 0 O:i 0 Q) N ~~ a. ~ a: w ro O:i O:i z-<?-oo .; ::;s '0 ~ 2 c ro ro :J . ~ ~ 0{ 0 'Of> ~ In Q) Q) 0 i~ 2 Vi Vi ~ ~ ~ (ijcrj ~ u; s: ~~ []~ II 0 o c '" ~" ~ 0 uu iLi'; ... e- o ~l c1w2066.0l m\gis-data\reports\feasibility study jan 2007 Page 47 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Map 2.28 Seminole Boat Ramp: Downtown Redevelopment Plan Character Districts ~ L. CQ)~ .., .., -"00-= ~ '-' .- 'C C I .c CU :;::"- ~ tn'" J.:~CUOO C):E Q) "- LL. J: C co cJ) Q..~ '- -- CCcJ) ~ (])'- oED - '- C 0.. (]) ~o_ o(])u O>~ (]) co "O..c (])() 0::: Q; " IL o o o N <:> 'C 1;; ~"O 0 '0 5~ ~~~ 5';..ge.~~ ~~.~8~~ ;: ~ D? i;j "" oro>-~C)5 'E~ci3~=c :~~~rriJ2~S~ lfluDwOO:lfl~ D~I ID[ co N " N C. CU :E (])o.. - E o co . ~ 0::: E- (]) co (/)0 co w ~ ::E <Ii ':'1 Ci I=%< U ~ ~~ ~~ oE ~5 UU ~.. ~ ~l 1M z-<?-. ~ C') (]) ~ '" "0 C ::l o co o o "! (/) o o or> c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 48 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 2.4 DRI Thresholds for High and Dry Marinas Historically, high and dry marinas in excess of 300 slips were presumed to be a Development of Regional Impact (DR!) and subject to a detailed review of the regional impacts associated with the facility. This review process is both costly and time consuming. When the scope of work for this study was approved by the City Council and the Florida Fish and Wildlife Conservation Commission, Florida Boating Improvement Program in Tallahassee, high and dry marina facilities were subject to this regional review. During the 2006 Legislative Session, the Florida Legislature eliminated the requirement that such facilities to undergo a formal DRI review. This action was due in part to the diminishing supply of high and dry storage facilities, the growing demand based on boater registration records and duplicative reviews, recognizing that State environmental permitting entities would still be involved in the review process through existing permit reviews and approvals (e.g. SWFWMD Environmental Resource Permit). Consequently, Clearwater's proposed high and dry facility will not be subject to the DRI review process. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 49 I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 3.0 Conclusion on Site Feasibility 3.1 Constraints and Opportunities This chapter explores the constraints and opportunities for each alternative site. These have been identified through data collection and analysis, as well as comments gathered from meetings with City Staff. A matrix has been prepared to summarize all the information and facilitate decision making for the recommended site. (See Table 3.1) 3.1.1 Jack Russell Stadium I I I I I I I I I I I The Jack Russell Stadium site is the largest in size of all alternatives facilitating accommodation of the programmed slips, co-related land uses (retail, repair shops, restaurants), parking spaces, etc. This site is the second closest to the Seminole Boat Ramp (0.5 mile), diminishing the traffic impact in relation to the Stevensons Creek Launch route. In addition, this site does not show any environmental constraints and offers the most complete provision of i nfrastructu re services. Some of the primary constraints of the Jack Russell Stadium site are the desires for other redevelopment projects at that location and the perceived desires of the North Greenwood community. There have been several uses proposed for the site, from workforce housing to mixed-use development. A project providing significant employment for residents could be worked into a larger development scheme. However, the need for affordable housing remains an issue in this neighborhood. There is a desire for a project that will enhance the community through economic development. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 50 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study A mixed, business-use project or a multiple marine services project could provide a tie-in to the industrial area located just south of the site. At this point, the City is still studying the best use of the site considering that it is one of the largest pieces of vacant land in Pinellas County. Currently, the Parks Department is leasing the baseball facility. The lease expires in February of 2007. There is a capital project to demolish the concrete portion of the stadium because it is structurally unsound. The city plans to reduce seating (the concrete stadium portion) and preserve the ball fields and the outlying buildings that are in good condition. The Boys and Girls Club are also using this facility. The height of the existing stadium is established and significant. A high and dry storage facility would be similar to that of the existing land use at this site. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 51 n ~ N o a- a- S 3 ,/ ~. "- " ;; ,/ ii! " o Gf ,/ ;;"' ~ g ~. 14 c: "- '< -';' :J N o o " 1:1 ~ ()Q (1) Ul N Table 3.1 City of Clearwater: High and Dry Multi-Site Feasibility Study Draft 11- Site Evaluation Matrix Site 1 Site 2 Site 3 Jack Russell Stevenson Creek Seminole General Size (acres) 18.08 a 8.41 a 5.91 a Existina Land Use of the Site Recreation/Open Space Recreation/Ooen Soace Recreation/Ooen Space Future land use of the site Recreation/Open Soace Recreation/Onen Snace Central Business District Zonina of the existina site Recreation/Ooen Soace Recreation/ODen Soace Downtown Potentiallmoact area (acres) 55.12 a 8.43 a 10.63 a Clearwater NelCl-hborhood District ND2 ND2 ND2 Environmental Constraints (none. mild. moderate severe) Manaroves None Severe None Seaarass None None Mild Permittina constraints None Severe Mild Floodina cateaorv None Moderate (1 OOV flood zoneT Severe (velocitv zone) Storm surae cateaorv None Severe (1-2) Severe-mild (1-5) Adiacent Existina Land Use to the Site (acres/Darcels) Sinale familv 10.65a/50p 5.10a/260 0.27a/30 Duolex- Tnolex 0.85a/5p 0.19a/10 0.15a/1O Multifamilv 8.24a/1 p 0.86a/iO 2.06a/20 Commercial 1.24a/40 2.28a/30 9.4a170 Mixed use - - - Industrial 3.17a/7p - - Recreational and ooen Soace 4.55a/1p - - Public Semi oublic 23.66a/70 - 1.56a/20 Vacant 2.76a/18p - 3.59a/10 Marina - - 0.70a/10 Adiacent Future Land Use (acres/Darcels) CBD- Central Business District - - 10.63a/15p RU- Residentjal Urban 10.26a/46p 5.29a/27n - RH-Residential Hiah 8.24a/10 - - RM-Residential Medium 2.49a/160 - - ROG-Residential Office General 1.29a/1 p - - RFH- Resort Facilities Hiah - 3. 14a/4n - CG-Commercial General 1 .99a/130 - - 1- Institutional 23.3a/8p - - IL-Industrial Licht 3.7a/8p - - ROS-Recreation Ooen Soace 4.55a/10 - - Adiacent Zonina D- Downtown - - 10.63a/150 LMDR- Low medium densitv residentjal 6.68a/250 5.29a/290 - MDR- Medium densitv residential 6.24a/380 - - MHDR- Medium hiah residential 8.24a/1 p - - OSR- Ooen Soace and Recreation 4.55a/1p - - 0- Office 0.29a/10 - - C- Commercial 1.82a/120 - - 1- Institutional 23.83anp - - IRT- Industrial Research Technoloav 3.47a/8p - - T- Tourism - 3. 14a/40 - Proiected Future DeveloDment within the ImDact Area Housina Units - 62 condos/ 24 units/6 townhomes 161 condos /36 townhomes Commercial Sa. - - - Industrial Sa. - - - Transnortation Potential launch Route (miles) 0.55 miles 1.05 miles - Predominant level of services on launch Route n/a C or better - Road Laneaae on Launch Route 2 lanes 2-3 lanes - Road Jurisdjction on Launch Route Municioal State/municioal - Adiacent Existina Land Use to the Launch Route (oarcels/frontaaes) Sjnale familv residential 1656f/110 1640fU270 - Duolex Triolex 47f/1 p 1141f/130 - Multifamilv 310f/4rl - Commercjal 907f/50 4110f/390 - Mixed Use - - - Industrial 308f/1 p 229f/2n - Recreational and ooen Soace 178f/20 356f/30 - Public Semi public 462f/30 969f/40 - Vacant 1300f/8p 1110f/170 - Recreational and ooen Soace - - - - - iAdiacent Future Land Use to the Launch Route (DarcelS/frontaaes) CBD- Central Business District 1562f/13p 991f/100 - RU- Residential Urban 2130f/26p 1268f/180 - RH-Residentjal Hiah - - - RM-Residential Medium - - - ROG-Residential Office General - - - RFH- Resort Facilities Hiah 989f/100 - CG-Commercial General 642f/6p 5977f170n - 1- Institutional 353f/10 355f/10 - IL-Industrial Liaht - - - ROS-Recreation Ooen Soace - - - M-Municjoal No Future land Use 179f/2p - - Availabilitv of Infrastructure (Yes/No) Existence of potable water lines Yes Yes Yes Existence of reclaimed water lines Yes No No Existence of storm water lines Yes Yes Yes Existence of sanitarY lines Yes Yes Yes. Neiahborhood ComDatibllltv Comoliance with Downtown Redevelooment Plans (Yes/No) No I N/a I Yes Exnected neiahborhood issues! none, some sianificant, severe) I Some Sianifjcant I None ~ . r:r I'D ~ W . .... tii ~ 0 Cl .. ~ ~ =+' I V'I ;:+. I'D l'Tl <: ~ l: ~ - O' ::::l ~ ~ - ::::!. x :r :h' :J- OJ :J :::t. CJ ~ 3::: OJ ..., S. OJ ~ o rD() Ii ;::;.: "'''' OJ ~ '..r, .V -. -.. 2':() ~2 '" ..., ~~ c OJ ~~ I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 3.1.2 Stevensons Creek The Stevensons Creek site is the second largest site and has the advantage of direct waterfront access, especially along the northern border of the site. It also has good access to the majority of infrastructure services, except reclaimed water. The existing bridge to the north of the site is too low to accommodate boat launching at the site. Only very low profile boats can pass under the bridge. If boat launching were desired, the bridge would need to be raised to accommodate most watercraft. In addition, the depth of the water at the site would make launching difficult. Estimated order of magnitude costs to raise the bridge and associated ramping improvements are $2-3 million. Dredging of Steven sons Creek is proposed in the future, however navigation under the existing bridge on North Fort Harrison remains an overwhelming constraint. The primary constraints for the Stevensons Creek site are the height of the existing bridge to the north of the site and the perceived desires of the surrounding neighborhood and traffic. Boat trailer traffic leaving the site would need to make a left turn onto North Ft. Harrison Avenue and adding a traffic light to the intersection would be difficult. The traffic in this area is already constrained and several traffic abatement projects are already in place. Environmental constraints were also identified as a constraint to the development of the high and dry storage facility on this site. The presence of a continuous mangrove shoreline of more than 1,500 feet would require a permit from Pinellas County Environmental Management to remove and trim mangroves at the site in order to facilitate development. In addition, the c1w2066.0l m\gis-data\reports\feasibilitystudy jan 2007 Page 53 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study seagrass bed could also impede the permitting of accessory docks or boat launches associated with a high and dry facility. There are also concerns about the need for mitigation of impacts such as minor repairing, painting, oil change, etc. related to the operation of this facility The existing surrounding neighborhood is primarily low-density single-family residential (south of the site) along with commercial uses and condominiums to the west. This neighborhood is more compatible with nature-based recreational boating, such as kayaking and canoeing as opposed to a high and dry facility. Traffic abatement is already in place and would be impacted if additional traffic were added to the neighborhood. The Stevensons Creek site is currently used by the City's Parks and Recreation Department for a lawn bowling/shuffleboard facility. The number of users of these facilities has been declining. The Stevensons Creek site was identified by staff as a possible location for a Senior Center. It was also identified as a possible relocation site for the Francis Wilson Theatre (currently at the Seminole Boat Ramp Site). c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 54 I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 3.1.3 Seminole Boat Ramp The Seminole Boat Ramp Site is constrained primarily by its size. The existing parking at the site would need to be maintained and an additional property (the Francis Wilson Theatre) would need to be added to the site boundary to accommodate the High and Dry structure. The relocation of the Francis Wilson Theatre should be considered if this site is selected. Currently, the Francis Wilson property has part of a 99-year lease with the City of Clearwater, of which only half has transpired. There are many opportunities identified within the Seminole Boat Ramp Site. Some of the most significant are: · The site has the best waterfront access of the three sites; · There are existing facilities already serving in site that could be used for the proposed high and dry (such docks and boat ramps) reducing construction costs. . The site has good access to infrastructure services, i.e., potable water, stormwater and wastewater I I I I . The City owns the site as well as adjacent sites facilitating land consolidation for phased expansion. . Due to the existing water-related use, the environmental impacts are anticipated to be manageable and could be mitigated. Additional environmental permits would be required for additional docks. · The Downtown Redevelopment Plan promotes the development of waterfront related activities such as marinas. It specifically mentions the c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 55 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Seminole Boat Ramp and provides general guidelines to improve the site and make it an end destination. . Adjacent developments include condominiums linked to private marinas, making the proposed project compatible with the existing redevelopment pattern. Some of the recommendations that evolved from discussions held with City staff regarding the development of a high and dry facility at the Seminole Boat Ramp site include: . Due to the land areas necessary to accommodate the facility and parking needs, the ownership of the "strip" of land between the Francis Wilson Theatre and the remainder of the site should be integrated into the site boundary. . Explore the possibility of maintaining trailer and car parking at the site by including of parking within the High and Dry structure and working with the grade/slope on the site to accommodate a split-level design. . Consider within the site planning and construction program, the effects on stormwater (retrofitting or other impacts). Additionally, upgraded landscaping was discussed to ensure compatibility with adjacent residential development, utilizing "green" design for the site (particularly the roof of the facility). This study concludes that the Seminole Boat Ramp Site shows the most favorable conditions for the development of the High and Dry facility. As discussed in sections 2.0 and 3.0, adverse environmental and transportation impacts, along with cost related issues played a strong role in excluding the Steven sons Creek and Jack Russell Stadium sites. The following chapter takes a closer look at several characteristics of the intended proposed faci I ity, setting the framework for the Conceptual Site Plan which is discussed in section 4.0 c1w2066.01 m \gis-dala \reports\feasibi Iity study jan 2007 Page 56 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 4.0 Design and Planning Standards for High and Dry Marina Facilities. The following chapter focuses on design and planning standards related to the development of high and dry facilities. 4.1 Defining the Building Size: Width, Length and Height. The building width for a high and dry facility will be determined by the size of the boats and the corresponding aisle size. Identifying the size of the boats that are intended to be stored in the High and Dry facility is extremely important considering they will dictate the size of the stacks to be used. Historically, sixteen to twenty- eight foot (16'-28') boats were considered typical for stack storage. Over several years the demand for larger boats (30' to 40') has increased. Experts agree that high and dry facilities should be designed to accommodate current and future market demands taking into consideration boat sizes. A detailed market demand study is recommended. Table 4.1 provides a general description of average boat sizes. Table 4.1 Average Boat Sizes Overall Length Width Height 24' to 26' 8' 6' 9' 3' 27' to 29' 9' 4' 10' 9' 30' to 32' 10' 9' 11' 7' 33' to 35' 12' 0' 12' 4' 36' to 39' 12' 7' 14' 2' 40' to 42' 12' 11' 15' l' Source: DSKA, 2006 Another important measure to define the building configuration of a High and Dry facility is the aisle, which is defined as the distance between two rack sections, allowing for the forklift truck to turn while carrying a boat. This measurement varies depending on: (1) the length of the boats, (2) the turning radius of the forklift or handing equipment and (3) the space available in the site. Typical aisle widths using boat lengths as the criteria are included in Table 4.2. As the boat lengths increase in the market, the forklift will require a larger turning radius. A minimum aisle width of 50' is very common. However, 60'-70' is becoming more common. If using angled racks, aisle width will be less. The accuracy of the measurement is extremely important considering that an extra one foot of building width may translate into thousands of dollars in cost. (Example: 12" of concrete 12" wide times 250' long aisle). Table 4.2 Typical Aisle Widths Boat Length Aisle Width Up to 30' 60' to 65' Up to 36' 65' to 70' 38' to 45' 70' to 75' Source: DSKA, 2006 c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 57 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study When calculating the building length, the size of the bays and the number of boats that fit within each bay must be considered. Some of the most common bays are: . 'Single wide' bays designed for one boat (i.e. 9', 10', 14' wide). . 'Double wide' bays spanning 20' to 25'. . 'Triple wide' 27'-31' bays allow for the greatest storage flexibility. The building height will be dictated by the City's Land Development Code. For planning purposes, every height of boat could be considered as 10'. More specific concerns about boat sizes will change the final layout. Of most concern are the first and the top levels of the structure. Boat heights (especially for large boats on the first level) may dictate clearances of 14 to 16 feet. If the structure will have a roof, top level minimums should be measured from the inside eave to ensure space is adequate to clear the roof design and any utilities (i.e. fire sprinkler systems). Table 4.3 shows the typical heights relating to rack levels: Table 4.3 Typical Heights for Rack Levels Rack Levels Height (Typical) Level 1 10' t016' Level 2 8' t012' Level 3 8' t010' Level 4, 5,6 8' Minimum Source: DSKA, 2006 4.2 Structure Types/ Building Design According to the permanence and flexibility of the structure, high and dry facilities can be (1) rack supported, (2) a separate clear span building with free standing racks, or (3) a vertical automated rack system. The following is a brief description of the benefits of each system: · Clear Span Building (free standing racks). These are temporary structures, composed of free standing racks. These cannot be easily modified if the boat sizes change. Due to the style of main frames, the leasable space may be minimized as the market changes. C\_ -- . . . . . . ~..... -.... ...... _.L- - - -- . . . . . . _""- _...._A--iL_ · Rack Supported Buildings. The structure is built with rack columns supported by a roof. Because the rack structure carries an increased load; the cost of the racks will increase, but roof and side building costs will be less, netting a slightly lower cost overall. One cost saving advantage of the rack supported building is c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 58 I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study the potential for an accelerated seven year tax write-off, since the entire structure may be considered a piece of equipment. If properly designed, the building will be adaptable to the market as changes occur. . Vertical Automated System. The Vertical Yacht Storage System is an automated and electric lifting and moving system. Unlike traditional forklift based operations, it allows storing any boat from an 18' open fisherman to an 80' express cruiser. It also offers reduced haul and launch times (as short as six minutes). The use of the system could reduce aisle space by up to 50 feet depending on the maximum size of boat to be stored. Because of the use of concrete on walls, the enclosed facility is generally capable of withstanding 140 mile per hour winds. I I I I I I I I Automated Lifting System I High Lift Marina 39'-0' 'r I I< , f:.:--" I, '.1 J ! I ~ ..r:r1.lj, .'.' ,. '" " " -r" " I . _~__ ~r\ ('D-. ~ ' ~-..::.; ..4 i j - I 'lJ- .' ~----~n ~~ ".".... 43"'()" , ~ :~,', . , . ~." '~ " I I ,,-J -~'l 33'.()"f~. ot' . .1 ., '-,,~"., .~ ~-: - ~ i::-r:e,.: ~ 42'..()*'ol,' -f;-<".' t T"rri Jo.. I;J:.--~ I I I Typical Plan Layout Page 59 I c1w2066.01m\gis-data\reports\feasibility study jan 2007 '---.1~ ~ 10 .. __ - I " , "-, 1-- "..11..= . i II~- ~. , I-~'~ ~I q :< \'(I~-- '.. ;~-! ~~ /~--~ : I I Typical Building Section I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study According to building typology, high and dry facilities can also be classified as1: · Racks. Portable free standing racks can be used to quickly double storage area. Designed as 4 (2 high 2 wide) boat modules or 6 (2 high 3 wide) boat modules. The modules can easily be picked up with a marina forklift and moved. These racks are generally recommended for additional storage outside of the high and dry structure. These are not recommended for the proposed facility due to the aesthetics (compatible with the adjacent residential properties) I I I I Rickenbacher Marina, Miami, FL . Racks with Roof. These are conventional racks with a single roof. The forklift area (aisle) is not under the roof and is open. These are not recommended for the proposed facility considering the need for an enclosed structure. Typical Building Section Racks with Roof Three-sided Buildings (some with sliding doors). Three sided storage facilities have three walls and a roof. They offer most of the advantages of conventional buildings. The forklift area (aisle) is not under the roof and is open. This building is not recommended for the proposed facility considering the need for optimizing the available space. I I I I I . I I I I I Typical Building Section Three-Sided facility Three-Sided Building with Sliding Doors, Victoria's Harbor Marina, GA Photo of Rack with Roof Facility I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 I Adapted from Roof and Rack. Brochure and webpage: http://www.roofnrack.com/ Page 60 I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study · Gabled Buildings. Gabled structures are "back-to-back" three-sided buildings. Sliding doors can be designed to enclose the forklift side. I I I I Typical Building Section Gabled Building Gabled Building with Sliding Doors, Sienns Boat Company, CA Considering the building program and City's requirements it could be said that the two preferred building typologies are: . Conventional Building. Conventional boat dry storage developments have racked boats on either side of an aisle. The aisle width is determined by the length of the boats and the turning radius of the marine forklift used to retrieve the boats. I I I I I Typical Building Section Conventional Building I Conventional Facility, Mid Islands Family Marina, Cape Coral, FL · Double Wide Building. The most efficient high and dry structure is a double wide building. The structure has two aisles with boats racked on either side. The structure is all under one roof, but may require some additional space. I I I I I Double Wide Facility, Bradenton Beach Marina, FL Double Wide Facility, Bahia Beach Marina, Ruskin, FL I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 61 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 4.3 Building Materials The preferred building material for high and dry facilities is steel (mainly galvanized) considering that is most flexible and cost effective than other construction materials. The steel has greater strength in comparison with other construction materials to handle large boat weight. In addition, "aesthetic options" could be added easily. 4.4 Site Planning Some of the most important elements that should be considered when preparing the site plan for a high and dry facility include. . Land Use and Zoning. Existing zoning designations should facilitate the development of the facility. . Program Area. The typical rule-of-thumb is about 2 acres for 200 boats for a conventional structure. In addition to the building footprint, land should be considered for travel areas, parking, offices, maintenance shops, wash down and boating cleaning areas, temporary racks area (for high demand) and other buildings. . Circulation. It is necessary to provide clear pedestrian and vehicle circulation patterns throughout the site. Appropriate turning radius should be designed to allow the movements of vehicles (cars, trailers and boats). Drystorage should be located as close to the water as possible to reduce the distance to which the forklift will carry and launch boats into the water. . Parking. The facility should provide parking access to users. The common parking ratio for high and dry facilities is 1 parking space to 5 storage boats. . Mitigate Environmental Impacts. Appropriate environmental permits should be obtained and mitigation measures should be designed to reduce environmental impacts (fuel management, etc.). . Noise Management. Appropriate buffers should be designed to avoid nuisance to neighboring properties. . Safety. Considering that steel is the most used material for the construction of high and dry facilities and the value of boats storage, there is a need to design for fire suppression. Easy access for emergency vehicles (fire, ambulances) should be provided. In addition, consideration should be given to design structures to withstand hurricane force winds. · Landscape and Aesthetics. Landscaping is an important tool to improve the character of the place, as well as to mitigate noise impacts. Facilities design should consider the character of the neighborhood in which they will be built. Specific design elements can be incorporated into building facades. · Building Flexibility. Adjustable and wider bays will ensure the building can grow with the times. It is preferable if the facility can combine boat and trailer storage. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 62 I- I i I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study The following images are provided as example designs of high and dry facilities: I I I I I I ,---- Cape Harbour Marina, Cape Coral, FL I I I I Cape Harbour Marina, Cape Coral, FL I I I I fast Marina, Cape Coral, FL I I I I Marina One, Deerfield Beach, FL Page 63 I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Bradenton Beach Marina, Bradenton FL I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 5.0 Proposed Facility 5.1 General Development Guidelines Assuming the Seminole Boat Launch as the preferred site, the City staff and Consultant defined general development guidelines for the proposed high and dry facility. Some of the most important guidelines or recommendations include: . Develop the program established by the City: an attractive building with sufficient parking, a staging area in order to get boats in and out of the water, small management office and restrooms and site upgrades to enhance the aesthetics of the program. . Accommodate most of the existing trailer parking. Currently there are approximately 135 car/trailer spaces on site. . Preserve existing docks and other site structures. . Maximum boat size to be stored is 35'. According to vessel registration records maintained by the State of Florida Department of Motor Vehicles and Highway Safety, 86% of the registered vessels in Pinellas County are below 25' in size. From the total vessels registered 11 % are between 26' to 39' in size. City staff defined that 35' maximum boat size was appropriate. . Approximately 250 to 300 slips should fit within the facility. . Consider the use of the Francis Wilson Theater as part of the site. . Be sensitive to existing and projected development within the area. . Keep the architecture of the building consistent with the surrounding neighborhood. . As for the type of building, a conventional, enclosed building is preferred. . Explore the possibility of using green building techniques (green roof). 5.2 Conceptual Diagrams The Consultant prepared six conceptual diagrams taking into consideration the guidelines previously discussed (See Option 1, 2, 3, 4, 5 and 6). Diagrams allowed staff to evaluate: · Alternative building typology such as conventional (two structures) versus double wide building within the site. · Building location. · Circulation patterns (pedestrian and vehicular) and landscaping · Potential use of the Francis Wilson Theater. · General parking locations The Options 1, 2, 5 and 6 display a double wide building (single structure) with a footprint of 260 foot x 250 foot. Options 3 and 4 show two conventional buildings with a footprint of 130 foot x 250 foot. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 64 I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study I I Taking into consideration costs, building location and circulation patterns, among other elements, City staff recommended the development of a conceptual site plan for Options 2 and 5. These options are very similar with the difference of incorporating the Francis Wilson Theater property for additional car/trailer spaces. Table 5.1 provides a description of the existing and proposed parking and boat storage capacity. I I Table 5.1 Existing and Proposed Parking and Boat Storage Capacity I Existing Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Condition Cars 42 95 95 70 55 95 61 Carl Trailer Spaces 134 135 135 136 186 170 200 Car Trailer Spaces (inside) 74 74 76 76 74 74 Estimated Slips' 300 300 300 300 300 300 I . Based upon selected building typology I I I I I I I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 65 I I I I I I I I I I I I I I II III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Option 1 ~ ~ CQ)~ -- .-.- ~ "'C(/)="'C C ..:..c ::::J ns _'- -111- J:::::Jns(/) C):E Q) .- u. ::I: .. r, I . . ... o "' .... ro OJ.... ::l c:: a.Oc 5 Q) c::'- UCllQ. 5 a:: 0 l) ~ "' ~ ~ J 52 .~ r:....... i~ ~ H ~ uu ;> Hili w z~w ~ ~ I I I I c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 66 I I I I I I I I I I I I I I I I I It] WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Option 2 >. '- CQ)>' -- .-'- >. "(/)=" C I .c ns ::::.- ~ -(/)- .c ~ ns (/) C)~ Q) .- LL :J: ~ o '" '" ro Cl~ ::l C c.'- t: IDCO (.) c;: CroQ, 00::0 () '" '" ~ .;' ~ : ~ i~ ~ ';5 Q h ~ u" ~i ~ .lid: IIiI w z~w ~ ;:: I I c1w2066.01m\gis-data\reports\feasibility study jan 2007 Page 67 I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Option 3 ~ ... CQ)~ -- .-'- ~ "CCI)="C C I .c ns ~.- ~ -(/)- .c~nsCl) C)~ Q) .- u.. ::J: ~ ~ '" '" ~ .. ::E : i:i: ~ :g f--; fii: W ::~ Cl 1i ~ ~:;; u. 1ii OJ CO) ::l c:: Q."c a Q) c::'- UroQ. 50::0 () w z~w g 3: I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 68 I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Option 4 ~ '- CQ)~ .... .... '-'- >-- "CCI)="C c: I .c _'- ::J ,,, ... .- -tn.... oC::JcuCl) C)~ Q) .- LL ::I: ~( I ! ~ '" '" ~ j ~ i~ E-4 ~ '" t:J~. ~a ~E ~ 55 ;> u. ro c)..,. ::l C a."c: g Q) c"- UmQ. 50::0 u w z~w g ~ I I I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 69 I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Option 5 ~ ... CCb~ ..... ..... .-'- ~ "CCI)="C t: .~ .c ::s n:s ..... .- -U)..... .s:::::snsCl) C):E Q) .- LL ::I: !if I .. I ~ o '" ... ~ ::;; 1 E2 i ~ E;;; j!!! Q ~~ ~ ~~ ;>- H... rn C)." :J C c..c ~ Q) c'- U(ll'Q. 8a:o <.) w .-<r. , ;: '" '" I I I I c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 70 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study Option 6 >. ~ CQ)>' ... ... .-.- >. "'0(1)="'0 c: I .c ca :;::.- ~ -rn'" J:~cu(l) C):E Q) .- LL :J: i'r I Ilf " ~ re on '" ~ i ::E J ~ .'" .., f~ ~ ~~ Q ot ~ 38 ;:> Hii ro OJ co ::s c: 0...- c: Q)C:o (.) c::;:: c:CllQ. 00::0 () w z~~ g ;: c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 71 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 5.3 Conceptual Site Plan 5.3.1 Description The proposed facility footprint is 250 feet (North-South direction) by 260 feet (East-West direction) and approximately 48 feet high. The first floor is designed to accommodate car/trailer parking spaces as well as offices and restrooms, while the second, third and fourth floor will accommodate vessel storage. The size will allow the storage of least 280 to 300 boat slips no larger than 35 feet. The building typology proposed was the double wide building. As previously explained, the structure has two aisles with boats racked on either side. Approximately 100 vessels can be stored per floor, considering four aisles of 25 vessels (10 feet for each vessel is considered) This typology, in contrast with the conventional building typology, allow to reduces building cost by eliminating the need for building two additional building walls and the corresponding structural elements. However, the building mass that results from the double wide building typology is considerable in relationship to the adjacent development. This could be sufficiently addressed by introducing fa<;ade elements and appropriate issue building massing. It is proposed that the building have a green roof incorporating the following advantages: a) improved stormwater management; b) attenuated noise levels; c) increased energy savings; d) provides additional green space; and e) enhanced aesthetics from the bluff. The building doors would be oriented toward the waterfront (west), where noise and views of the High & Dry operation would be removed from on the residential uses north and south of this site. A twenty foot setback has been provided along the north and east of the property lines, with a 100 foot setback from west sea wall. The conceptual site plan proposes pedestrian and vehicle access from Seminole Street. Pedestrian access is limited around the building for security purposes. Two phases have been assumed considering the future use of the Francis Wilson Theater (see conceptual site plans 1 and 2). Phase 1 will accommodate approximately 155 car parking spaces and 33 car/trailer spaces outside of the building. If the Francis Wilson Theater property is incorporated in the future in Phase II, the site will be able to accommodate approximately 119 car parking spaces and 69 car/trailer spaces outside of the building. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 72 ~-€ '"J ::; 3: V; ~c <lJ '_ D] b .~ .~~ Ul!! ~ ~ '" c: .;:: '"J ~ C a '"C c: '" ..c: ::..0 i aflNaAV Vl03JSO o ~ -::: ~--= \ . ~ ~ \~ ~ .....- .. 00 \ .0 .- - .- C.J ~ ~ ~ J- ~ "C C ~ ~ .c ~ OJ) = == ~ I Q.~~ ~ ~.- ~ 00 = c.. Q ~ U ~ ~ e =0 ~ - Q C .- S ~ 00 ~ ~ :.> I:: ~ ~ v 0 <:: Ql Vl e '" Vl .c en 0 .Q > en c Ql Vl U .S .0 ro .<:: .S ro 1'l <:: CIl "0 i: al ;j i: N :; 2:- .c u .!!1 '" co ~ co 0, Vl '" i5.. en i: i5.. co ~ ro '0 Ql "0 ~ ro fi <:: <:: 0 <:: "0 CIl co ro ro .0 i: .~ co CIl CIl 0 ~ Ql .>< ,... 'CO <:: ts Vl .8 .0 E ro OJ .2' CIl > Q.I Ql Vl u e co a. <Il "0 ro CIl co E CIl l!? > a. a. 0 "0 ~ 'iij Vl .s Ql a. fi > .J: ~ <:: ~ e Q.. CIl .~ > x g a. e 0) tt: S C a. '<t 'i' ~ S r- a. fi e Q.. "0 :::s Q.I .~ ~ 2:- 0) s:l - <:: C;; "0 o/j ~ ~ .c en ~ ~ :E - .9- c.. Iii Q.I + V 0 It) ... C N 0 U ~ QJ rIJ. ~ .: ~ M I'.. (l) 00 m CI.... o o G '" S .= c~ 'S .~ Q :." "Q ;;: c ';; Q l:: U ~ ~~ Q.; l:: ;;~ ~ eo: o:l /-/ " ------". *-- // '..... Z ,. , .. } '-- _/' "- ~ .~ >. >- ~~ 'tl ~ ~ Ea .q~ :.c 'Vi .. ~::: ("1 ~ :90 -;;; t ~ '/l \C 0 ~ ~~ c. ~ t..l...("1 -;;; ~:?; 1; 'tl ~o~ J. 'bo -aU E c:~ 0 '" ~ ..c.~ .,; ~ .~ E ~ :Cc... u ~-€ f";J ::J ;::li) f;j ;;:..... ClJ .-:: D] "- '- o i8 .2~ \...J~ ~ ~ f";J c: .;:: f";J ~ c- a "'C c: '" ~ i 'JlflN'JIJ\ V V.O'Jl.::>SO .c o o o [J l... o 1: ~ ..:::: ~-- \ --=- '\ ~ ~ \~ QJ ~ .- 00 ~ ~ (: ~ <..l ~ - ..... - ..... C'..J c:lS ~ ~ '- Q "0 = c:lS ~ -= ~ OJ) = 53 ~ I c.~~ QJ --.,..... e.J 00 = c. Q ~ U ~ N ~ ~ QJ ~ rIJ. - ~ ~ ~ 'S ~ ~ .//_.~' Z \--; \'- _/' c:: <I> Vl 1: '0 '" Vl s:: Cl 0 .9 > Cl 11l <I> Vl u .!: LJ ~ .= e 10 <I> c:: OJ 1ii 'E .S! c:: 8 ::J 'E N :; :c s:: .!l! 11l '" ~ '" OJ Vl '" Ci Cl fd ::J OJ 1ii 'E Ci Q- '" ~ s:: '0 <I> c:: l!! a, :;: .8 19 .~ c:: "C ~ "C 1ii 1ii c:: N '" <I> ::J c:: .8 "C <I> ~ 'C:: c:: iV '" .8 <I> E ~ en .", Vl .!!! > '" '" Vl e c. CIl OJ ro <I> ~ 8 c:: r= al l!! > c. 5 al en '" .s .J: c. c:: c. E > c: /I) 0 Q.. "C 2 ;:, Vl i 5. '" c:: ~ > x '0 Il= .s s::: e <I> ~ 0 c. r= c. ro Q. Q.. .;; u .... e .E ..... "C ::is ~ E :;: .~ .~ <I> P:! c: rJ) ~ E-4 "C r= o(l ~ :J s:: ~ Cl - :c c.. .9- ~ Vi U -.!. .. s::: + 0 0 U to N '" E = = ~ 's .g .g ~ g ~ U 8 ~~ a; " :;-2'. ... ~ CQ /'/ .- ..---------.. ;;.. -0 ~gj ~ .f'~ L....... := N I:""'"""' ~ ~ ~~ ~~ u... "I c:::: ~ Cl d ;:;>- ~ 'tt: .~.'[ .2P e :r:o... '<t r-.... Q) 00 '" 0... 8 N c: .~ >. -0 :J '" &' :0 'Vi ~ ~ ~ t: 8- J ~ ... -0 J. 'bi:> E o .,; '" o ~ U I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 5.3.2 Zoning and Community Development Code Considerations for the Proposed Conceptual Site Plan The Seminole Boat Launch site is zoned Downtown (D) District (as well as the properties north and south of the subject site). The proposed High & Dry facility falls under "marina/marina facilities", which is defined as: "Marina means any structure constructed on pilings over open water or supported by flotation on the water which provides three or more boat slips for the purpose of sale or lease." Marina facilities means a use of land involved in the operation of a marina including structures and activities normally integral to the operation of a marina, such as servicing, fueling, pumping-out, chartering, launching and dry-storage of boats and boating equipment. In the Downtown District, marina/marina facilities are listed as a Flexible Development (FLD) use, requiring Community Development Board (CDB) approval. Table 2-903.D. of the current Community Development Code of the City of Clearwater indicates the maximum height as 30 feet and the minimum required parking as one space per slip. Considering that the preliminary proposed height is 48 feet and that the parking ratio is based on wet slips (not dry slips), a parking reduction will likely be required to accommodate the facility. One required space per slip far exceeds the parking demand for this facility. It is recommended that the project be processed as a Comprehensive Infill Redevelopment Project. Section 2-903.H Community Development Code lists the flexibility criteria for marina/marina facilities: "1. The parcel proposed for development is not located in areas identified in the Comprehensive Plan as areas of environmental significance including: a. The north end of Clearwater Beach; b. Clearwater Harbor grass beds; c. Cooper's Point; d. Clearwater Harbor spoil islands; e. Sand Key Park; f. The southern edge of Alligator Lake. 2. No commercial activities other than the mooring of boats on a rental basis shall be permitted on any parcel of land which is contiguous to a parcel of land which is designated as residential in the Zoning Atlas, unless the marina facilities are totally screened from view from the c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 75 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study contiguous land which is designated as residential and the hours of operation of the commercial activities are limited to the time period between sunrise and sunset; 3. The design of all buildings complies with the Downtown District design guidelines in Division 5 of Article 3; and 4. All marina facilities shall comply with the commercial dock requirements set forth in Section 3- 601.C.3 and the marina and marina facilities requirements set forth in Section 3-603."2 Section 3-603 of the Community Development Code has various standards and criteria for marinas and marina facilities that should be reviewed as they relate to the design and operation of the proposed facility. The site is located in the Old Bay District of the Downtown Redevelopment Plan. The Plan provides a maximum Floor Area Ratio (FAR) of 0.50 and a maximum height of 100 feet. As stated previously, the Downtown Redevelopment Plan shows only one Policy that speaks directly to this site (Policy 3 in the Old Bay District), which states: "The Seminole Street Launching Facility should be maintained as a recreation site, recognized as an area attraction and should be improved with the addition of elements such as picnic areas, park benches, landscaping, lighting and parking management." The project will need to meet the applicable Downtown Design Guidelines. Any docks associated with this High & Dry facility will need to meet the requirements of Section 3-601.C.3 and should be included in the Flexible Development application to the Community Development Board. The proposed dock off the western seawall would require City, State and Federal permits / appraisals which are perceived to be obtainable. 5.4 Cost Estimates In the conduct ofthis study the Consultant conferred with two nationally recognized builders of high and dry facilities. The first is Roof and Rack, who develops rack, supported buildings with boat forklifts (conventional) and Vertical Yachts who develop vertical automated systems. Order the magnitude costs estimates for the Clearwater proposed High and Dry facility are provided in this section taking into consideration the proposed type of faci I ity. According to Roof and Rack, for the type of facility that the City of Clearwater is intending to develop, the cost ranges from $16,000 to $22,000 per vessel including; design, permitting, site work, foundation, fire sprinkler, electricity, trim packages and other amenities. Additional, the City should consider the cost of $15 per square foot to build a green roof. This will add a cost of at approximately $975,000 to the project. 2 Adapted from comments provided by Wayne Wells (City of Clearwater, Planning Department) regarding conceptual diagrams (option 2 and 5) c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 76 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study In addition, potential marina equipment should be considered which includes: Table 5.2 Estimated Cost for Marina Equipment Equipment Cost Forklifts (22,000 @ 96" Load Center)- (2) $ 550,000 Floor cleaning machine $ 14,000 *Water recycling unit $ 36,000 Industrial forklift $ 12,000 Installed Pem bunk covering (580 boats) $ 52,000 Miscellaneous equipment and tools $ 10,000 Computer system with marina software $ 25,000 *Sewage pump out unit $ 12,000 Service cart $ 5,000 Total estimated $ 716,000 Source: Coastal Marine International, 2006 Under the conventional system, the facility could cost approximately $ 8.3 million. There are other costs generally associated to this type of facility: launch area with staging dock; fuel dock; engineering; personnel; insurance; permitting and impact fees that should be considered. According to Vertical Yachts, a vertical automated system for the desired capacity (250-300 vessels) will cost from $15,000 to $20,000 per boat. This cost includes design, technology and building construction. No site design, planning and construction are estimated in these figures. If the design of the building is enhanced to meet the adjacent development character, it is estimated that $3,500 dollars needs to be added to each vessel. Taking this figures into consideration, the building itself could cost between $4.6 to $7.0 millions dollars. Vertical Yachts recommends staging docks for the dry stacks that will add 500,000 dollars to the site planning and construction costs. The City should, after endorsing the preferred site, look closely to both systems identifying advantages, disadvantages and detailed cost estimates. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 77 I I I I I I I I I I I I I I I I I I I III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study 6.0 Next Steps. As stated in Chapter 1, this study provided the opportunity for the City to complete a site feasibility analysis considering three proposed sites: Jack Russell Stadium, Stevenson Creek and Seminole Boat Launch Ramp. Based on this study, the existing Seminole Boat Launch Ramp Site is the preferred site for the development of the High and Dry facility. The study also identified some of the general design and planning standards related to high and dry facilities, defined general development guidelines for the specific site, developed six alternative conceptual site plans for the preferred site and concluded with a conceptual site plan for the facility. Considering that the main objective of this project was the selection of the preferred site to develop the high and dry marina, it is recommended: a) The City endorse the Seminole Boat Launch Site as the preferred site for its future High and Dry Storage Facility. b) A second study phase could be authorized to include: . A detailed market study documenting existing and future demand, . Defining the preferred system of storing and retrieving boats from the high and dry faci I ity and detai led costs associated with those faci I ities. · Preparing the preliminary engineering studies and preliminary site plan for the preferred site. · Providing detailed construction cost estimate for the preferred system . Developing a detailed cost revenue analysis including funding options. c1w2066.01 m\gis-data\reports\feasibility study jan 2007 Page 78 I I I I I I I I I I I, I I I I I I I I APPENDICES III WADETRIM City of Clearwater High and Dry Marina Multi-Site Feasibility Study APPENDIX 1: APPENDIX 2: Delta Seven: Environmental Assessment Bathymetric Survey Stevenson Creek Site c1w2066.01 m\gis-data\reports\feasibility study jan 2007 I I I I I I I I I I I I I I I I I I I APPENDIX 1 Delta Seven Initial Environmental Assessment c1w2066.01 m\gis-data\reports\feasibility study jan 2007 I I I I I I I I I I I I I I I I I I I -~~---~-~~ -- -~~--- /-^~ (~ 5w~ ~" ~~~---~-_.--- .C"'\ 1 : , , General Environmental Consulting Clearwater High and Dry Multi-site Feasability Study i i : : . May 10, 2006 i ! l i I Prepared by: De!ta Seven Inc. p.o. Box 3241 Saint Petersburg, FL 33731 , ; , I I I I I I I I I I I I I I I I I I I Clearwater Hi~h and Dry Multi-site Feasability Study Back~round In March of 2006, Delta Seven was asked by Wade Trim, Inc. to provide a cursory review of the environmental resources at the Seminole Boat Ramp and Stevenson Creek sites as they pertain to the potential development of high and dry boat storage facilities. This review includes the identification of seagrasses and mangroves as well as a rendering of the general location of these resources. This report is intended to document the results of the field study associated with this effort and to give a general overview of the impact of environmental resources on regulatory and permitting approvals that would be necessary for the development of the project. A general analysis of permitting requirements, as well as a site specific analysis is provided. All information contained in this report results from field surveys, review of existing records, and analysis of aerial photography from 2000-2004. General Permitting Standard permitting requirements will need to be met, or resolved regardless ofthe site chosen for development of a high and dry boating facility. Wetland and surface water requirements are addressed by this report, with upland permitting issues being addressed by Wade Trim in other reports. Regardless of the site chosen, permitting of any docks, boardwalks, platforms for boat forklifts, or accessory facilities designed to be built in or over wetlands and surface waters must obtain permits from the following agencies: Pine lias County Water and Navigation Control Authority, State of Florida Department of Environmental Protection or the Southwest Florida Water Management District, and the US Army Corps of Engineers. Additionally, each of these agencies will notify and accept comments from other agencies such as Environmental Protection Agency, Florida Fish and Wildlife Conservation Commission, and US Fish and Wildlife Service. In general it will be expected that the following criteria be met for permits to be issued: · Sufficient water depth for navigation of vessels (depth varies depending on the permitting agency). Water quality will not be degraded as a result of development of the site pursuant to F.A.C. chapters 40D and 62. This will include providing water quality analysis, results of pollution dispersion studies, and providing plans for preventing degradation of water quality during construction. Construction and maintenance of the facility will not adversely impact flora and fauna species, with specific criteria addressing seagrass, mangroves, and threatened and endangered species. The facility must meet public interest criteria, including reasonable assurance that . . . I I I I I I I I I I I I I I I I I I I the project will not negatively impact natural resources, public health, navigation and water flow, commercial or recreational water dependent activities, historic or archaeological resources, and water quality. · A hurricane plan must be developed pursuant to 166-321U) Pinellas County Land Development Code . No docking facility may extend greater than 25% of the width of waterway pursuant to Chapter 18-20 F.A.C. The waters of both the Seminole Boat Ramp and Stevenson Creek sites are located within the Pinellas County Aquatic Preserve and are classified as Outstanding Florida Waters, which increases the level of regulatory control and subjects the projects to greater scrutiny under the above criteria. Seminole Boat Ramp Seminole Boat Ramp, located at the western terminus of Seminole Street in downtown, is the site of an existing boat ramp facility and large parking area. The facility, with easy access to Clearwater Harbor and the Intercoastal Waterway, currently provides public boat launches and an ingress/egress channel. This property is currently owned and maintained by the City of Clearwater. The adjacent parcel west ofthe boat ramp is owned by the West Coast Inland Navigation District. The shoreline of the property, with one exception, is made up of existing seawall and is devoid of mangrove vegetation. The seawall itself is in relatively good condition with minimal damage. The exception is a 50 foot area just west of the launch ramp which is populated with palms and shore grass. To the south of the property, immediately waterward of the seawall is a small linearly oriented oyster bed that has established itself on submerged debris such as concrete rubble. No seagrasses were observed within the confines of the submerged lands that lie immediately south of the boat ramps and extend south to the end of the parking lot. It is believed the submerged lands within this area are owned by the City of Clearwater, however title research has not been conducted to confirm this information. Should submerged lands not be owned by the City, or should additional submerged lands outside the boundaries of City property be required for the development of the project, a submerged lands lease would need to be obtained from the Board of Trustees of the Internal Improvement Trust Fund of Florida. Beginning approximately 100 off of the southern seawall of the site is an extensive seagrass bed that continues to the vicinity of the Drew Street fishing pier. The grass bed covers the extent of the shallow flats in this area and would severally inhibit development of a marina facility anywhere within the confines of the grass bed. The grass does not extend into the basin at the base of the existing boat ramps on site and therefore is not likely to serve as an impediment to permitting of accessory docks or boat launches associated with the high and dry facility. Sufficient water depth is present in the basin to provide for mooring and navigation of vessels, as I I I I I I I I I I I I I I I I I I I demonstrated by the current use of the facility. It is not likely that dredging would be needed in order to facilitate the use of this area for a high and dry facility as boat launching and navigation activities would not change from the current patterns of ingress and egress to the site. The existing water depths along the western seawall near the parking lot is likely sufficient to allow the construction of docking facilities for use by boats being launched from the high and dry facility. It is likely 15-20 slips could be designed along this wall that could be used by vessels being launched on site and transient vessels wishing to access the site. Stevenson Creek The site under review at Stevenson Creek, located at the intersection ofN. Fort Harrison and Calumet Street, is the current site of the Lawn Bowls and Shuffleboard Complex. The 5.5 acre site is currently owned by the City of Clearwater with the adjacent submerged lands believed to be owned by the State of Florida. Current use of the site does not include any marina related activities. The primary ecological feature associated with the site is the presence of approximately 1,500 linear feet of mangrove shoreline. This mangrove shoreline averages 30 feet deep when measured from the most waterward tree to the most upland tree. The shore vegetation is comprised primarily of mangroves, with sporadic oak. trees, palm trees, and exotic canopy trees such as Brazilian pepper. The presence of a continuous mangrove shoreline creates a need to obtain a permit from Pinellas County Environmental Management to remove and trim mangroves at the site in order to facilitate the development of the high and dry facility. Portions of the mangroves would be required per this permit to neither be trimmed or impacted. No seagrasses were observed during the site visit and it is not believed that significant seagrass growth occurs on the submerged lands where the accessory facilities would be located for the project. The State of Florida would likely require a seagrass survey be conducted during the growing season to verify that seagrasses are not present on site. Significant issues in regards to water depth are presented at this site. While no official bathymetric survey has been conducted to assess water depths, observations on site indicate that less than the required three feet of water at Mean Low Water is likely present on site. Dredging would be required in order to facilitate navigation in the area. Generally, permits for new dredging for marinas are difficult to obtain from the regulatory agencies, particularly inside the confines of an Aquatic Preserve such as at the Stevenson Creek site. Depth of water is not the only concern at the site, as the Fort Harrison bridge crossing Stevenson Creek is low enough to limit the size of vessel that could navigate underneath it. It is believed that the Board of Trustees of the Internal Improvement Trust Fund of Florida holds title to the submerged lands adjacent to the site, with the exception of 1.5 acres of privately held submerged lands on the northern shoreline of the area. This privately held area would not likely impact the project. State ownership of the submerged lands would obligate that a submerged lands lease be obtained from the Board of Trustees in order to construct facilities over these lands. I I I I I I I I I I I I I I I I I I I Summary The Seminole Boat Ramp and Stevenson Creek sites have both been assessed in terms of permitting issues and ecological resources. Both sites include ecological features that need to be considered as a component of the permitting process and issues with submerged land ownership that need to be resolved. Each site has features, or lack thereof, that make it a favorable site for the project, such as the lack of seagrass present at Stevenson Creek or the existing ingress and egress channels at Seminole Boat Ramp. Certainly fewer ecological hurdles to permitting exist at the Seminole Boat Ramp site. The agencies would potentially view the development of the high and dry facility and associated accessory docks and piers as an expansion of an existing marina facility, which the regulatory agencies generally give preference to in comparison with the development of a new facility. In order to facilitate permitting, data needs to be obtained on existing water quality, tidal dispersion, water depth (bathymetric survey), and ownership of the submerged lands. Formal seagrass surveys, floral and faunal analysis, and further ecological assessment of both sites needs to occur. It is expected that permitting for the activities over wetlands and surface waters would take 12-18 months in order to complete. I I I ~SW0M I I I I I I I I I I I I I I I I Clearwater High and Dry Stevenson Creek Site Initial Ecological Assessment ~1';(i>'1 Mangrove dominated shoreline ~ Navigation limited by depth o I 250 I 500 Feel I ~ I I I ~~~~Thl I I I I I I I I I I I I I I I I j\j II I- I Clearwater High and Dry Seminole Boat Ramp Site Initial Ecological Assessment D ....:::::.-.. Seminole Boat Ramp Site Extent of sea grass bed Navigable waterways Oyster bed .,':: .~~. l I . o I 175 350 I 700 Feet I I I I I I I I I I I I I I I I I I I I APPENDIX 2 Bathymetric Survey Stevensons Creek Site c1w2066.01 m\gis-data\reports\feasibility study jan 2007 o t ~ - ~ ~ ~:< .." .~ " '" ~ U> '"' <:1 6 ;z g ~ ~~ ~ = + '" z OREO<iE PLAN REACH I SfE'IEc:fIK'C'[IIlIlIOR.OOfO CIH.ndoj....,. c_..... c'"o,,~.... :=;...... ~." -.. ..~ ~~ 1.'.t. ........""I2t:P.xx.X.UU _.,.IIo,...oo_nn 1.1.1. ~f~ ,~~; NNN-NN. NNN DEPARTMENT or THE ARMY J,\,(;I(SONVllLE OISTRlCT. CORPS or ENGINEERS JAC:KSON....UE. FLORIO'\' 0< i~$D. ...... "'..,. i~ 11 ,. .i I 'i'i! i'-.~ 2: ~ I il c;> I o ~ CLENlWATER.~I.ORIOA SECTION 20& ENVIRONMENTAl.. RESTORATION PROJECT STEVENSON CAEEI< is ---l-'--~--r > m ~-~l----'~- I tr=-. <;J o ~ ~ ':1 6 z ~ ." I = + .... z 'I: o. " () I io o '" ~ ClEN!WATEA,FlORIOA SEctION 2011 ENVIRONMENTAl RESTORATION PROJECT STEVENSON CREEl< ,.. , o".,Ipoo.., 121011-ST(V((:lll('CNIOO2DCl1 .LW.N.. OR(OCE PlAN REACH II ~ - 5T[V(CI!K-C-C_.oo. clM-MC",,",.4qn ~_A9" "Melrl," clMt""'l.d9' -.. ..~ C..... 7.1.1 ........""2f'.~lC.J(.UXJ( ....-..... I>o_oo_nn 1,U. D,O.fIlE NO. NNN-NN, NNN --yyyy OEPAAtl.4ENT Of THE ARMY JACKSONVILLE DISTRlCT. CORPS Of' ENGINEERS JACICSONVLLE, FLORIDA